SSwi8tch2moKde Power Supply  
Ultimate DIN-track-mounting Power Supply  
with a Wide Power Range from 3 to 240 W  
• Wide power range: 3 to 240 W  
• Wide AC input voltage range: 100 to 240 V on one body.  
• Undervoltage alarm function (indicator) incorporated as stan-  
dard. (With the 240-W models, applicable only to the “-T” mod-  
els.) 90 and 100-W models standardized with the alarm output.  
• Output/input terminal parts separated on body upper/bottom  
side, respectively, for safe and smart wiring.  
• Multiple pairs of output terminals;  
Three pairs for 90, 100, and 240-W models  
Two pairs for 30 and 50-W models  
• Finger-safe terminal block with cover according to VDE0106/  
P100.  
• Conforms to the stringent EN50081-1 standard for universal  
use in any environment subject to EMI conditions (except for  
240-W models) in addition to EN50082-2 conformity for use at  
any EMS environment.  
• DC output ports comply to EN55022 class A, thus ensuring use  
in any environment subject to EMI with recommended external  
filters (3- to 100-W models).  
• Meets EN61000-3-2 (limits for harmonic current emissions) with  
PFC on 90, 100, and 240-W models.  
• Parallel running operation (100 and 240-W models).  
• Class 2 approved (except for 240-W models and 7.5-W dual  
output models).  
• Approvals of various international safety standards for industrial  
control equipment and industrial computing systems (ITE/TE),  
in addition to other important approvals.  
• Six-language instruction manual provided.  
Model Number Structure  
I Model Number Legend  
S82K -  
1
2
3
4
1. Power Factor Correction  
None: No  
3. Output Voltage  
05: +5 VDC  
P:  
Yes  
12: +12 VDC  
15: +15 VDC  
24: +24 VDC  
27: 12 VDC  
28: 15 VDC  
2. Power Ratings  
003: 3 W  
007: 7.5 W  
015: 15 W  
030: 30 W  
050: 50 W  
090: 90 W  
4. Undervoltage alarm indicator/output  
<For 3- to 100-W models>  
None: Yes  
<For 240-W models>  
Switch mode Power Supply S82K  
L-5  
Ordering Information  
I List of Models  
Power ratings  
Output voltage  
Output current  
Function Configuration  
Models  
Output  
Undervoltage  
alarm indicator/  
output  
PFC  
3 W  
5 V  
0.6 A  
Single output  
Yes  
No  
S82K-00305  
S82K-00312  
S82K-00315  
S82K-00324  
S82K-00705  
S82K-00712  
S82K-00715  
S82K-00724  
S82K-00727  
S82K-00728  
S82K-01505  
S82K-01512  
S82K-01524  
12 V  
0.25 A  
0.2 A  
15 V  
24 V  
0.13 A  
1.5 A  
7.5 W  
5 V  
12 V  
0.6 A  
15 V  
0.5 A  
24 V  
0.3 A  
+V12/V12  
+V15/V15  
5 V  
0.3 A/0.2 A  
0.2 A/0.2 A  
2.5 A  
Dual output  
15 W  
30 W  
Single output  
12 V  
1.2 A  
24 V  
0.6 A  
5 V  
5.0 A  
S82K-03005  
(see note 1)  
12 V  
24 V  
24 V  
24 V  
2.5 A  
1.3 A  
2.1 A  
3.75 A  
S82K-03012  
S82K-03024  
S82K-05024  
S82K-P09024  
S82K-09024  
S82K-P10024  
S82K-10024  
S82K-24024T  
S82K-P24024  
S82K-24024  
50 W  
90 W  
Yes  
No (see note 4)  
100 W  
240 W  
24 V  
24 V  
4.2 A  
(see note 2)  
Yes  
No (see note 4)  
10 A  
(see note 3)  
No  
Yes  
No  
No  
Note: 1. The output capacity of the S82K-03005 is 25 W.  
2. The output current during parallel operation is 3.78 A.  
3. The output current during parallel operation is 9 A.  
4. Comply to EN61000-3-2 A14  
I Accessories (Order Separately)  
Mounting Track  
50 cm (l) × 7.3 mm (t)  
PFP-50N  
1 m (l) × 7.3 mm (t)  
PFP-100N  
1 m (l) × 16 mm (t)  
for 3- to 50-W models  
for 90-W and 100-W models  
PFP-100N2  
S82Y-JF3-N  
S82Y-JF6-N  
Noise Filter  
L-6  
Switch mode Power Supply S82K  
Specifications  
I Ratings/Characteristics  
3- to 240-W models without PFC  
Item  
Single output  
Dual  
Single output  
50 W 90 W  
outputs  
3 W 7.5 W  
7.5 W  
15 W  
30 W  
100 W  
240 W  
Efficiency (typical)  
60% to 80% (Varies depending on specifications.)  
100 to 240 V (85 to 264 V)  
Input  
Voltage  
(see note 1)  
AC  
100 V (85 to 132 V)/  
200 V (170 to 264 V)  
Selectable  
100 V (85 to  
132 V)/  
200 V (170 to  
253 V)  
Selectable  
DC  
90 to 350 V (see note 2)  
50/60 Hz (47 to 450 Hz)  
Not possible  
Frequency  
Current  
100-V  
0.15 A  
max.  
0.25 A max.  
0.45 A  
max.  
0.9 A  
max.  
1.3 A  
max.  
2.5 A max.  
1.5 A max.  
5.5 A max.  
3.5 A max.  
(see note 3) input  
200-V  
input  
0.25 A  
max.  
0.6 A  
max.  
0.8 A  
max.  
Power factor  
---  
Leakage cur- 100-V  
0.5 mA max.  
1 mA max.  
15 A max.  
30 A max.  
Yes  
rent  
input  
(see note 3)  
200-V  
input  
Inrush cur-  
rent  
(see note 3)  
100-V  
input  
25 A max.  
50 A max.  
200-V  
input  
Noise filter  
Note: 1. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards.  
2. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC.  
3. Defined with a 100% load and the rated input voltage (100 or 200 VAC).  
Switch mode Power Supply S82K  
L-7  
3- to 240-W models without PFC  
Item  
Single output  
Dual  
outputs  
Single output  
3 W 7.5 W  
7.5 W  
15 W  
30 W  
50 W  
90 W  
100 W  
240 W  
Output  
Voltage adjustment  
10% (V.ADJ)  
Not possi-  
ble (see  
note 3)  
10% (V.ADJ); 10% to 15% for S82K-03012/-03024/-05024  
(see note 2) range  
Ripple (see note 1)  
2% (p-p) max.  
Input variation  
influence  
0.5% max. (at 85 to 264 VAC input, 100% load)  
0.5% max. (at 85 to  
132 VAC/170 to  
264 VAC input, 100%  
load)  
0.5% max.  
(at 85 to  
132 VAC/  
170 to  
253 VAC  
input,  
100% load)  
Load variation  
influence  
1.5% max.  
(0 to 100% load)  
+V: 1.5% 1.5% max.  
1.5% max.  
(10 to  
100% load)  
max.  
(0 to 100% load)  
V: 3%  
max.  
(0 to 100%  
load)  
Temperature variation 0.05%/°C max.  
influence (see note 1)  
Start up time  
100 ms max. (up to 90% of output voltage at rated input and output) 200 ms max.  
20 ms min.  
300 ms  
max.  
Hold time  
(see note 1)  
Additional Overload protection  
function  
105% to 160% of  
rated load current,  
inverted L drop,  
automatic reset  
(see note 4)  
105% to  
250% of  
105% to 160% of rated load cur- 101% to  
rent, inverted L drop, automatic 111% of  
105% to 160% of rated  
load current, inverted L  
rated load reset  
current, in- (30-W, 50-W models: inverted L current, in-  
verted L drop, intermittent, automatic re- verted L  
rated load drop, automatic reset  
drop, auto- set)  
matic reset  
drop, auto-  
matic re-  
set (see  
note 5)  
Overvoltage  
protection (see note 6)  
No  
S82K-  
24024T  
model only  
Undervoltage alarm  
indicator (DC LOW  
indicator)  
Yes (color: red)  
No  
S82K-  
24024T  
model only  
Undervoltage alarm  
output (DC LOW  
output)  
Yes  
S82K-  
24024T  
model only  
Parallel operation  
Impossible  
Possible (2 units max.)  
(see note 7)  
Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC).  
2. The output specification is defined at the power supply output terminals.  
3. The settings for the output voltage must be within the following range:  
+V: 1% of the rated value  
V: 5% of the rated value  
4. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the protection function will operate  
at a current of 95% to 160% of the rated load current.  
5. When the ambient temperature exceeds 25°C, the protection function will operate at a current of 92% to 111% of the rated load current.  
6. Circuit-breaker type. To reset, turn the input power supply OFF, then after 1 min has elapsed, turn the input power supply ON again.  
7. Parallel operation is set with the Parallel/Single Operation Selector Switch. (This setting is not required for S82K-10024 models.)  
L-8  
Switch mode Power Supply S82K  
3- to 240-W models without PFC  
Item  
Single output  
Dual  
Single output  
90 W  
outputs  
3 W 7.5 W  
7.5 W  
15 W  
30 W  
50 W  
100 W  
240 W  
Other  
Ambient temperature Operating: See the derating curve in the Engineering Data section  
(no condensation or icing)  
Storage:  
Operating: 25% to 85%  
Storage: 25% to 90%  
25°C to 65°C (no condensation or icing)  
Ambient humidity  
Dielectric strength  
3,000 VAC at 50/60 Hz for 1 min (between all inputs and outputs)  
2,000 VAC at 50/60 Hz for 1 min (between all inputs and GR terminal)  
1,000 VAC at 50/60 Hz for 1 min (between all outputs and GR terminal)  
Alarm current: 10 mA (3- to 7.5-W models) 20 mA (15- to 100-W models) 25 mA (240-W models)  
Insulation resistance 100 Mmin. at 500 VDC (between all outputs and all inputs/GR terminal)  
Vibration resistance Malfunction: 10 to 55 Hz, 0.375-mm single amplitude for 2 hrs each in X, Y, and  
Malfunction: 10 to  
55 Hz, 0.15-mm  
single amplitude  
for 2 hrs each in X,  
Y, and Z directions  
Z directions  
Malfunction: 300 m/s2, 3 times each in X, Y, and Z directions  
Shock resistance  
Screw tightening  
torque  
0.74 N m max. (see note 2)  
Output indicator  
Yes (green)  
Electromagnetic  
interference  
(see note 1)  
Conforms to FCC class B  
Conforms to FCC class A  
EMC  
(see note 3)  
3 to 100-W Models  
(EMI):  
EN50081-1  
Emission Enclosure:  
Emission AC Mains:  
EN55022 class B (equivalent to EN55011 class B)  
EN55022 class B (equivalent to EN55011 class B)  
Emission Output Ports: EN55022 class A (with a recommended optional filter) (see note 3)  
240-W Models  
(EMI):  
EN50081-2  
EN55011 class A  
EN55011 class A  
Emission Enclosure:  
Emission AC Mains:  
Common to All Models  
(EMS):  
EN50082-2  
Immunity ESD:  
EN61000-4-2: 4-kV contact discharge (level 2)  
8-kV air discharge (level 3)  
Immunity Burst:  
Immunity Surge:  
EN61000-4-4: 2-kV power-line (level 3)  
2-kV output line (level 4)  
EN61000-4-5: between 2-kV lines (except for 240-W models)  
between 4-kV line and FG (except for 240-W models)  
Approved standards Class 2 (UL 1310)/Class 2 (CSA C22.2 No. 950) (see notes 4 and 5)  
UL 508 (Listing)/1950  
UL 508 (Listing)/  
1012  
CSA C22.2 No.14,  
CSA E.B. 1402C,  
EN50178  
CSA C22.2 No.14/No.950, EN50178 (VDE0160), EN60950  
Conforms to VDE0106/P100  
(VDE0160),  
EN60950  
Conforms to  
VDE0106/P100  
Weight  
150 g max.  
260 g  
max.  
380 g  
max.  
400 g  
max.  
600 g max.  
1,800 g max.  
Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC).  
2. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals.  
3. To ensure the emission ratings, a noise filter should be used on the output lines at the closest point.  
(3- to 50-W models: S82Y-JF3-N, 90- and 100-W models: S82Y-JF6-N)  
4. Models other than dual output models satisfy the Class-2 requirements.  
5. To meet Class-2 requirements with the 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A  
max. should be wired in series with the load to be connected to the power supply. Only then can the power supply output be considered  
as meeting Class 2.  
Switch mode Power Supply S82K  
L-9  
90-/100-/240W models with PFC (S82K-P@@@24 models)  
Item  
Single output  
100 W  
60% to 80% (Varies depending on specifications.)  
90 W  
240 W  
Efficiency (typical)  
Voltage  
Input  
100 V (85 to 132 VAC)/200 V (170 to 264 VAC) Select- 100 to 230 V (85 to 253 VAC)  
able  
Frequency  
50/60 Hz (47 to 63 Hz)  
Current  
100-V input 2.5 A max.  
4 A max.  
2 A max.  
0.95 min.  
0.95 min.  
(see note 1)  
200-V input 1.0 A max.  
100-V input ---  
Power factor  
200-V input 0.7 min.  
Leakage current 100-V input 0.5 mA max.  
(see note 1)  
200-V input 1 mA max.  
Inrush current  
(see note 1)  
100-V input 25 A max.  
200-V input 50 A max.  
Yes  
Noise filter  
Output  
(see note 2)  
Voltage adjustment range  
Ripple (see note 1)  
10% (V.ADJ)  
2% (p-p) max.  
Input variation influence  
0.5% max. (at 85 to 132 VAC/170 to 264 VAC input,  
100% load)  
0.5% max. (at 85 to 253 VAC input,  
100% load)  
Load variation influence  
Temperature variation  
Startup time  
1.5% max. (0 to 100% load)  
0.05%/°C max.  
200 ms max.  
1.5% max. (10 to 100% load)  
1,000 ms max.  
Hold time (see note 1)  
Overload protection  
20 ms min.  
Additional  
function  
101% to 111% of rated load 105% to 160% of rated load current, inverted L drop, automatic re-  
current, inverted L drop, auto- set  
matic reset (see note 3)  
Overvoltage protection  
No  
Under voltage alarm indicator Yes (color: red)  
No  
No  
Under voltage alarm output  
Parallel operation  
Yes  
Impossible  
Possible (2 units max.) (see note 4)  
Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC)  
2. The output specification is defined at the power supply output terminals.  
3. When the ambient temperature exceeds 25°C, the protection function will operate at a current of 92% to 111% of the rated load current.  
4. Parallel operation is set with the Parallel/Single Operation Selector Switch.  
L-10  
Switch mode Power Supply S82K  
90-/100-/240W models with PFC (S82K-P@@@24 models)  
Item  
Single output  
100 W  
Operating: See the derating curve in the Engineering Data section (No condensation or icing)  
Storage: 25°C to 65°C (no condensation or icing)  
Operating: 25% to 85%  
Storage: 25% to 90%  
90 W  
240 W  
Other  
Ambient temperature  
Ambient humidity  
Dielectric strength  
3,000 VAC at 50/60 Hz for 1 min. (between all inputs and outputs)  
2,000 VAC at 50/60 Hz for 1 min. (between all inputs and GR terminal)  
1,000 VAC at 50/60 Hz for 1 min. (between all outputs and GR terminal)  
Alarm current: 20 mA (90- and 100-W models) 25 mA (240-W models)  
Insulation resistance  
Vibration resistance  
100 Mmin. at 500 VDC (between all outputs and all inputs/GR terminal)  
Malfunction: 10 to 55 Hz, 0.375-mm single amplitude for 2 Malfunction: 10 to 55 Hz, 0.15-mm single  
hrs each in X, Y, and Z directions  
amplitude for 2 hrs each in  
X, Y, and Z directions  
Malfunction: 150 m/s2, 3 times each in X, Y, and Z direc- Malfunction: 300 m/s2, 3 times each in  
tions X, Y, and Z directions  
Screw tightening torque 0.74 N m max. (see note 2)  
Output indicator Yes (Green)  
Shock resistance  
Electromagnetic inter- Conforms to FCC class A  
ference  
(see note 1)  
EMC (see note 3, 4)  
90-, 100-W Models  
(EMI):  
EN50081-1  
Harmonic Current:  
Emission Enclosure:  
Emission AC Mains:  
EN61000-3-2 (200 VAC input only)  
EN55022 class B  
EN55022 class B  
Emission Output Ports: EN55022 class A (with a recommended optional filter) (see note 3)  
240-W Model  
(EMI):  
EN50081-2  
EN61000-3-2  
EN55011 class A (see note 4)  
EN55011 class A  
Harmonic Current:  
Emission Enclosure:  
Emission AC Mains:  
Common to All Models  
(EMS):  
EN50082-2  
Immunity ESD:  
EN61000-4-2: 4-kV contact discharge (level 2)  
8-kV air discharge (level 3)  
Immunity Burst:  
Immunity Surge:  
EN61000-4-4: 2-kV power-line (level 3)  
2-kV output line (level 4)  
EN61000-4-5: between 2-kV lines (except for 240-W models)  
between 4-kV line and FG (except for 240-W models)  
Approved standards  
Weight  
Class 2 (UL1310)/Class 2 (CSA C22.2 No. 950) (see note 5) UL508 (Listing)/1012  
UL508 (Listing)/1950  
CSA C22.2 No. 14/E.B. 1402C, EN50178  
CSA C22.2 No. 14/No. 950, EN50178 (VDE0160), EN60950 (VDE0160), EN60950, Conforms to  
Conforms to VDE0106/P100  
VDE0106/P100  
1,000 g max.  
2,200 g max.  
Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC)  
2. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals.  
3. To ensure the Emission Enclosure ratings, a noise filter should be used on the output lines at the closest point. (90- and 100-W models:  
S82Y-JF6-N)  
4. To ensure the Emission Enclosure rating, a ferrite ring core should be used on all cables.  
5. To meet Class-2 requirements with the 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A  
max. should be wired in series with the load to be connected to the power supply. Only then can the power supply output be considered  
as meeting Class 2.  
Switch mode Power Supply S82K  
L-11  
Connections  
I Block Diagrams  
S82K-003@@ (3 W)  
S82K-007@@ (7.5 W, Single Output)  
Fuse (1 A)  
AC (L)  
+ V  
Noise filter  
AC (N)  
V  
Inrush current Rectifier  
protection circuit  
Rectifier  
Undervoltage  
alarm  
indicator  
Drive control  
circuit  
Overload  
alarm  
circuit  
Detector  
Photocoupler  
S82K-007@@ (7.5 W, Dual Outputs)  
Fuse (1 A)  
AC (L)  
V  
Noise filter  
AC (N)  
Inrush current  
protection circuit  
Rectifier  
Rectifier  
3-terminal  
REG  
+ V  
Undervoltage  
alarm  
indicator  
Drive control  
circuit  
Rectifier  
Detector  
Overload  
alarm  
circuit  
Photocoupler  
S82K-015@@ (15 W)  
S82K-030@@ (30 W)  
S82K-05024 (50 W)  
Fuse (3 A)  
AC (L)  
+ V  
Noise filter  
AC (N)  
V  
Inrush current  
protection circuit  
Rectifier  
Rectifier  
Undervoltage  
Drive control  
circuit  
alarm  
indicator  
Overload  
alarm  
circuit  
Detector  
Photocoupler  
L-12  
Switch mode Power Supply S82K  
S82K-09024 (90 W)  
S82K-10024 (100 W)  
Fuse (5 A)  
Rectifier  
+ V  
AC (L)  
Noise filter  
AC (N)  
V  
Rectifier  
Inrush current  
protection circuit  
100 or 200 V  
Selectable  
terminals  
(see note)  
Drive control  
circuit  
Undervoltage  
alarm indicator  
Overload  
alarm  
circuit  
Detector  
Photocoupler  
Note: Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and  
remove the short bar to select 200 to 240 VAC.  
S82K-P09024 (90 W)  
S82K-P10024 (100 W)  
Harmonic current  
emission control  
(200-V input only)  
Inrush current  
protection circuit  
Fuse (5 A)  
Rectifier  
+ V  
AC (L)  
Noise  
filter  
AC (N)  
V  
Rectifier  
100 or 200 V  
Selectable  
terminals  
(see note)  
Drive control  
circuit  
Undervoltage  
alarm indicator  
Overload  
alarm  
circuit  
Detector  
Photocoupler  
Note: Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and  
remove the short bar to select 200 to 240 VAC.  
S82K-24024@ (240 W)  
Fuse (5 A)  
AC (L)  
INPUT  
Noise filter  
AC (N)  
+ V  
Inrush current  
Rectifier  
DC  
100 or 200 V  
Selectable  
terminals  
protection circuit  
OUTPUT  
V  
(see note 2)  
Rectifier  
Detector  
Drive control  
circuit  
DC LOW  
Photocoupler  
Undervoltage  
alarm  
indicator/output  
Overvoltage  
alarm circuit  
Overload alarm  
circuit  
(see note 1)  
Overvoltage protection circuitry (see note 1)  
Note: 1. The overvoltage protection circuitry and undervoltage alarm indicator are available  
in the S82K-24024T only.  
2. Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and  
remove the short bar to select 200 to 230 VAC.  
Switch mode Power Supply S82K  
L-13  
S82K-P24024 (240 W)  
Fuse (8 A)  
AC (L)  
INPUT  
AC (N)  
+ V  
DC  
OUTPUT  
Noise filter  
V  
Inrush current  
protection circuit  
Harmonic current  
emission control  
Smoothing  
Rectifier  
Rectifier  
Drive control  
circuit  
Overload alarm  
circuit  
Detector  
Photocoupler  
L-14  
Switch mode Power Supply S82K  
I Installation  
S82K-007@@ (Dual outputs)  
S82K-015@@  
S82K-003@@/S82K-007@@  
(Single Output)  
1
1
1
1
5
7
5
7
5
7
6
6
2
3
2
3
2
3
S82K-@09024/S82K-@10024  
S82K-030@@/S82K-05024  
1
8
1
5
7
6
5
7
6
2
3
2
3
4
Bottom view  
(Only for S82K-  
P10024)  
6 7 5  
1
8
S82K-@24024@  
9
2
3
4
Bottom view  
1. DC Output Terminals: Connect the load lines to these terminals.  
2. Input Terminals: Connect the input lines to these terminals.  
3. Ground Terminal (GR): Connect a ground line to this terminal.  
4. Input Voltage Selector Terminals: Selects a 100 V or 200 V input voltage.  
5. Output Indicator (DC ON): Lights while a Direct Current (DC) output is ON.  
6. Output Voltage Adjuster(V.ADJ): It is possible to increase or decrease the  
output voltage.  
7. Undervoltage Alarm Indicator (DC LOW): Other than S82K-24024 and  
S82K-P24024 models.  
8. Undervoltage Alarm Output (DC LOW): S82K-@09024/-@10024/-24024T  
models only.  
9
9. Parallel/Single Operation Selector: Set to "PARALLEL" or "P" for parallel  
operation.  
Switch mode Power Supply S82K  
L-15  
Operation  
I Undervoltage Alarm Indicator and Output Function  
(All Models Except for S82K-24024/P24024)  
If the output voltage at the output terminal drops to 75% to 90% of the rated voltage, the red indicator of the S82K (DC LOW indicator) will be lit.  
In the case of the S82K-@09024/@10024/24024T, a voltage drop alarm will be output via the relay available in the models (DC LOW output).  
Note: This function detects the voltage at the output terminal of the Power Supply. To check the precise output voltage, measure the voltage at the  
terminal of the load.  
Indicator  
Voltage  
Operation of @09024/@10024/  
24024Ts output (DC LOW output)  
(see note 2)  
If the voltage at the output terminal is more than 82% of  
the rated voltage and operation is normal, the green in-  
dicator will be lit and the red indicator will not be lit.  
Green:  
DC ON  
Red:  
DC LOW  
DC ON  
If the voltage at the output terminal drops to below 82%  
of the rated voltage, the red indicator will be lit. (See  
note 3.)  
Green:  
(see note 1)  
Red:  
DC LOW  
DC ON  
If the voltage at the output terminal approaches 0 V,  
both the green and red indicators will not be lit.  
Green:  
Red:  
DC LOW  
Note: 1. The more the voltage at the output terminal drops, the darker both the green and red indicators will be.  
2. The relay contacts have a capacity of 0.1 A at 24 VDC.  
3. The red indicator will actually first light at a voltage between 75% and 90% of the rated voltage.  
Engineering Data  
I Reference Value  
Item  
Value  
Definition  
Reliability (MTBF)  
135,000 hrs min.  
MTBF stands for Mean Time Between Failures, which is calculated according to the prob-  
ability of accidental device failures, and indicates reliability of devices. Therefore, it does  
not necessarily represent a life of the product.  
Life expectancy  
8 yrs. min.  
The life expectancy indicates average operating hours under the ambient temperature of  
40°C and a load rate of 50%. Normally this is determined by the life expectancy of the built-  
in aluminum electrolytic capacitor.  
I Derating Curve  
3-/7.5-/15-/30-/50-/100-W Models 100-W Models without PFC 100-W Models with PFC  
Single-Unit Operation  
Parallel-Unit Operation  
Parallel-Unit Operation  
Installation A  
Installation A  
90  
Installation B  
Installation A  
Installation B  
S82K-P10024:  
85-VAC input  
S82K-P10024:  
85-VAC input  
65  
65  
Installation B  
S82K-03005  
Installation A  
Ambient temperature (°C)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Note: When using the 7.5-W single-output  
models within the input voltage range  
between 90 and 110 VDC, the load  
rate will become 90% or less.  
L-16  
Switch mode Power Supply S82K  
90-W Models  
Single-Unit Operation  
240-W Model  
Single-Unit Operation  
240-W Model  
Parallel-Unit Operation  
Installation A  
Installation A  
90  
S82K-P09024:  
85-VAC input  
70  
Installation A  
65  
S82K-P24024:  
100-VAC input  
(see note)  
S82K-P24024:  
100-VAC input  
(see note)  
Installation B  
Ambient temperature (°C)  
Ambient temperature (°C)  
Note: 100-VAC input: 85 to 132 VAC  
(A) Standard (Vertical) Installation (B) Horizontal Installation  
Ambient temperature (°C)  
Note: 100-VAC input: 85 to 132 VAC  
Top  
Top  
(Not permitted for  
240-W models.)  
S82K-@@  
Note: The derating curve above can be ensured for  
the above two kinds of installations.  
I Overload Protection  
The Power Supply is provided with an overload protection function that protects the load and the power supply from possible damage by overcur-  
rent. When the output current rises above a set value (refer to the table below), the protection function is triggered, decreasing the output voltage.  
When the output current falls within the rated range, the overload protection function is automatically cleared.  
Single output  
Dual  
outputs  
Single output  
3 W 7.5 W  
7.5 W  
15 W  
30 W  
50 W  
90 W  
101% to  
111% of rat- current (see note 3)  
100 W  
240 W  
Set value  
Operation  
105% to 160% of rated load 105% to  
current (see note 1) 250% of rat-  
105% to 160% of rated load current  
105% to 160% of rated load  
ed load cur-  
rent  
ed load cur-  
rent (see  
notes 2 and  
3)  
Inverted L drop type, automatic reset  
Inverted L drop/intermittent Inverted L drop type, automatic reset  
operation type, automatic  
reset  
Note: 1. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the overload protection function  
will operate at currents from 95% to 160% of the rated load current.  
2. When using the 90-W model at an ambient temperature exceeding 25°C, the overload protection function will operate at currents from  
92% to 111% of the rated load current.  
3. When using the 100-W model with PFC in parallel operation, the overload protection function will operate at currents from 3.78 to 4.2 A.  
Switch mode Power Supply S82K  
L-17  
3-/7.5-/15-/90-/100-/240-W Models  
30-/50-W Models  
Rated voltage  
Rated voltage  
Intermittent  
operation  
0
50  
100  
Output current (%)  
Output current (%)  
Note: Do not short-circuit the output terminals of the S82K or use the S82K with excessive output current for a long time, otherwise the  
internal circuitry of the S82K may be deteriorated or damaged.  
When Using Output Models  
The +V output detects the total output power (+V output and -V output) to trigger the short-circuit protection against overcurrent. This protection  
varies depending on the -V output state. The -V output independently triggers the short-circuit protection.  
I Overvoltage Protection (S82K-24024T Models Only)  
The Power Supply is provided with an overvoltage protection function that protects the load and the Power Supply from possible damage by over-  
voltage. When the output voltage rises above a set value, the protection function is triggered, shutting off the output voltage. If this occurs, reset  
the Power Supply by turning it off for 1 minute min. and then turning it on again.  
Overvoltage  
protection  
operating  
10%  
Rated output  
voltage  
Variable range  
10%  
I Inrush Current, Startup Time, Hold Time  
Input OFF  
Input ON  
AC input voltage  
Inrush current on input application  
AC input current  
Output voltage  
90%  
96.5%  
Hold time  
(20 ms min.)  
Startup time: 100 to 1000 ms  
max. depending on the model.  
L-18  
Switch mode Power Supply S82K  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Mounting Brackets  
(Supplied with the Switching Power Supply)  
Used when not mounting the Power Supply directly  
on the DIN track.  
S82K-003@@ (3 W)  
S82K-007@@ (7.5 W)  
Two, 4.5 0.1 dia.  
25 0.15  
35 0.15  
27 0.1  
37.5 0.1  
Mounting Holes  
Attached  
Mounting  
Bracket  
M3.5 with square washer  
(sliding  
7 max.)  
M4 or 4.5-dia.  
hole  
Note: If more than one Power Supply is installed in a  
row, keep a distance of 20 mm min. (L = 20 mm  
min.) between each adjacent Power Supply.  
S82K-015@@ (15 W)  
45  
9.8 8.3  
7.5  
45  
35  
75 58.1  
91  
5
4.6  
M3.5 with square  
washer  
(sliding 7 max.)  
Mounting Holes  
Two, M4 or 4.5-dia. mounting holes  
Note: If more than one Power Supply is installed in a row, keep  
a distance of 20 mm min. (L = 20 mm min.) between each  
adjacent Power Supply.  
60  
L
35  
Switch mode Power Supply S82K  
L-19  
S82K-030@@ (30 W)  
S82K-05024 (50 W)  
Four, 4.5 dia.  
35  
M3.5 with square washer  
(sliding 7 max.)  
4
Mounting Holes  
Four, M4 or 4.5-dia. mounting holes  
Note: If more than one Power Supply is  
installed in a row, keep a distance of  
20 mm min. (L = 20 mm min.) between  
each adjacent Power Supply.  
60  
L
80  
S82K-@09024 (90 W)  
S82K-@10024 (100 W)  
145  
135 0.2  
Four, 4.5 dia.  
9.8  
8.3  
7.5  
45  
35  
58.1  
75  
60 0.2  
91  
5
M3.5 terminal screw  
M3.5 with square washer  
4
(sliding 7 max.)  
Short bar  
Mounting Holes  
Four, M4 or 4.5-dia. mounting holes  
Note: If more than one Power Supply is  
installed in a row, keep a distance of  
20 mm min. (L = 20 mm min.) between  
each adjacent Power Supply.  
60  
L
135  
L-20  
Switch mode Power Supply S82K  
280  
270 0.2  
8.3  
S82K-@24024@  
7.8  
9.8  
Four, 4.5 dia.  
27.5  
35  
112.8  
130  
100  
M3.5 terminal screw  
Short bar  
138  
4.2  
115 0.2  
4
M3.5 with square washer  
(sliding 8 max.)  
Mounting Holes  
L
270  
115 0.2  
Four, M4 or 4.5-dia. mounting holes  
Note: If more than one Power Supply is installed in a row, keep a distance of  
20 mm min. (L = 20 mm min.) between each adjacent Power Supply.  
I Accessories  
Mounting Track (Order Separately)  
PFP-100N/PFP-50N  
PFP-100N2  
16  
7.3 0.15  
4.5  
4.5  
27 24  
1
29.2  
1.5  
35 0.3  
27 0.15  
1
35 0.3  
15 25  
25  
25  
25 15  
15 25  
25  
25  
25  
10  
10  
10  
10  
1,000  
15 (5)  
(see note)  
1,000 (500)  
(see note)  
Note: The values shown in parentheses are for the  
PFP-50N.  
Noise Filter (Order Separately)  
S82Y-JF3-N for 3- to 50-W Models  
S82Y-JF6-N for 90- and 100-W Models  
Two, 4.8 dia.  
(Mounting  
holes)  
A max.  
B 1  
16 max.  
16 max.  
D 1  
4
39 0.5  
Nameplate  
47 1  
4
6.5  
6.5  
Six, M4  
C 0.5  
Model  
A
107  
B
C
D
S82Y-JF3-N  
S82Y-JF6-N  
75  
85  
90  
100  
26  
30  
117  
Switch mode Power Supply S82K  
L-21  
Precautions  
To dismount the Power Supply, pull down portion (C) with a flat-blade  
screwdriver and pull out the Power Supply.  
!Caution  
Be sure to connect the grounding line. Not doing so may result in  
electric shock.  
!WARNING  
Do not attempt to disassemble the Power Supply or touch its inter-  
nal parts while power is being supplied. Doing so may result in  
electric shock.  
Do not touch the terminals of the Power Supply within one minute  
after power has been turned OFF. Doing so may result in electric  
shock due to a residual voltage.  
30 mm min.  
Do not touch the Power Supply Unit while power is being supplied  
or immediately after power has been turned OFF. Doing so may  
result in a skin burn due to high temperature of the Power Supply.  
C
Track stopper  
When tightening the terminals, do not tighten the terminal block to a  
torque greater than 75 N.  
Mounting  
Selection of 100 or 200 VAC Input  
Voltage  
(S82K-@09024/-@10024/-24024/-24024T)  
To improve and maintain the reliability of the Power Supply over a  
long period of time, adequate consideration must be given to heat  
radiation.  
The Power Supply is designed to radiate heat by means of natural  
air-flow. Therefore, mount the Power Supply so that air flow takes  
place around the Power Supply.  
Select a 100 V or 200 V input by shorting or opening the Input Volt-  
age Selector Terminals, as shown in the following diagram.  
The default setting is 200 V.  
100 V Input  
Air  
When mounting two or more Power Supplies side-by-side, allow at  
least 10 mm spacing between them, as shown in the following illus-  
tration.  
Use the short bar to short-circuit  
terminals 7 and 8.  
Forced air-cooling is recommended.  
200 V Input  
10 mm min.  
Remove the short bar.  
Generating Output Voltage ( )  
Short bar  
To mount the Power Supply on a DIN track, hook portion (A) of the  
Power Supply to the track and press the Power Supply toward direc-  
tion (B).  
An output of can be generated by using two Power Supplies as  
shown below, because the Power Supply produces a floating output.  
+V  
INPUT  
(A)  
V  
+V  
INPUT  
V  
(B)  
When connecting the Power Supplies in series with an operation  
amplifier, connect diodes to the output terminals as shown by the  
dotted lines in the figure. No diodes are required with S82K 90-W/  
100-W/240-W models.  
L-22  
Switch mode Power Supply S82K  
Wiring  
Parallel Operation  
Carefully wire the input/output terminals while paying attention to  
their polarities so as to prevent incorrect wiring.  
S82K 100-W/240-W models can be operated in parallel.  
Perform parallel operation with power supplies satisfying the same  
specifications.  
Battery Charging/Backup  
100- and 240-W Models  
With S82K-@09024/-@10024/-24024T models, a reduction in lifetime  
due to over discharge of the battery can be prevented using the DC  
LOW output. (Discharge can be interrupted at 0.75 to 0.9 × 24 V.)  
+V  
Load  
INPUT  
V  
Example: Lead Storage Battery Backup Circuit  
14  
+V  
INPUT  
15  
V  
+V  
Fuse/Circuit breaker  
16  
Note: When operating the S82K-P10024 or S82K-@24024@ in paral-  
lel operation, set the switch to PARALLEL.Refer to the derat-  
ing curve for the rated current under this operation.  
9
DC Low  
10  
11  
3-, 7.5-, 15-, 30-, 50- and 90-W Models  
+V  
12  
V  
Load  
INPUT  
13  
V  
Note: 1. For details of charging voltages and charging currents, refer  
+V  
to the specifications for the battery.  
INPUT  
2. In order to prevent overvoltage to the battery, install an ov-  
V  
ervoltage protection circuit (90/100-W models).  
3. To protect the battery in the event of incorrect operation,  
such as load short-circuiting, be sure to install a fuse or cir-  
cuit breaker.  
Parallel Operation Precautions  
The length and thickness of each wire connected to the load must  
be the same so that there is no difference in voltage drop value  
between the load and the output terminals of each Power Supply.  
4. To limit the level of charging current to the battery, install an  
overcurrent limit circuit.  
With other models, when connecting a battery to the load, install an  
overcurrent limit circuit and overvoltage protection circuit.  
Adjust the output voltage of each Power Supply so that there will be  
no difference in output voltage between each Power Supply.  
If the S82K-P10024 or S82K-@24024@ models are used in single  
operation under the parallel operation setting, the overcurrent pro-  
tection will be actuated at an output of 90% to 95% (in current), and  
will not allow a 100% output.  
If the S82K-P10024 or S82K-@24024@ models are used in parallel  
operation under the single operation setting, one of them will oper-  
ate at 110% output, causing severe heat derating and shortening  
the service life.  
Series Operation  
S82K 90-W/100-W/240-W model can be operated in series.  
It must be noted that the + output of the 7.5-W dual output model  
cannot be connected in series to its output.  
90-, 100-, and 240-W Models  
+V  
INPUT  
V  
+V  
INPUT  
V  
3-, 7.5-, 15-, 30-, 50-W Models  
+V  
INPUT  
V  
+V  
INPUT  
V  
Switch mode Power Supply S82K  
L-23  
Minimum Output Current  
The minimum output current of the S82K-00727 and S82K-00728 is  
restricted by the output voltage and control method.  
Note: All the outputs of the S82K-00727 and S82K-00728 are con-  
trolled by the +V output. If the +V output current falls to 10% or  
less of the rated output, the V output voltage may drop.  
Operating and Storage Environments  
Do not use or store the Unit in the following places, otherwise the  
Unit may malfunction or the characteristics of the Unit may deterio-  
rate.  
Locations subject to direct sunlight.  
Locations subject to ambient operating temperatures outside the  
range indicated by the derating curve.  
Locations subject to ambient operating humidity outside the range  
of 25% to 85%.  
Locations subject to condensation as the result of severe changes  
in temperature.  
Locations subject to ambient storage temperatures outside the  
range of 25°C to 65°C.  
Locations subject to corrosive or flammable gases.  
Locations subject to dust (especially iron dust) or salts.  
Locations subject to shock or vibration.  
Locations subject to exposure to water, oil, or chemicals.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
Cat. No. M048-E1-06  
L-24  
Switch mode Power Supply S82K  

相关型号:

S82K-24024

Power Supply Module
OMRON

S82K-24024T

Switch mode Power Supply
ETC

S82K-P09024

Switch mode Power Supply
ETC

S82K-P10024

Switch mode Power Supply
ETC

S82K-P24024

Switch mode Power Supply
ETC

S82L-0315

Power Supply Module
OMRON

S82L-1012

Power Supply Module
OMRON

S82L-1512

Power Supply Module
OMRON

S82L-1515

Power Supply Module
OMRON

S82L-1524

Power Supply Module
OMRON

S82L42PC

UNIVERSAL PERIPHERAL INTERFACE CHMOS 8-BIT SLAVE MICROCONTROLLER
INTEL

S82L42PD

UNIVERSAL PERIPHERAL INTERFACE CHMOS 8-BIT SLAVE MICROCONTROLLER
INTEL