SLA-440-ASA [ETC]

Diversified Electronics;
SLA-440-ASA
型号: SLA-440-ASA
厂家: ETC    ETC
描述:

Diversified Electronics

文件: 总3页 (文件大小:214K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
800.727.5646  
atcdiversified.com  
Diversified Electronics  
SLA Series  
The ATC Diversified SLA Series is designed to protect 3-phase equipment  
against PHASE LOSS, UNDER VOLTAGE, and PHASE REVERSAL  
conditions.  
With normal operating voltages applied in the proper ABC sequence, the  
internal relay will energize (PICK-UP). When incorrect phase sequence or  
phase loss occurs or the three-phase voltages fall below the drop out  
voltages, the relay will de-energize (DROP-OUT). On models featuring  
indicators, the LED glows when all line conditions are normal.  
STYLE “A”  
STYLE “N”  
Both Delta and Wye systems may be monitored. In Wye systems, connec-  
tions to neutral are NOT required.  
For UL Listed units, with field wiring terminals, copper wire with  
60°/75°C rating must be used for control circuitry connections.  
NOTE: When a phase is lost while the motor is running, a condition known as  
regeneration occurs where a voltage is induced into the open phase nearly  
equal in magnitude to the normal phase-to-phase voltage. However, with the  
exception of lightly loaded motors, enough change is detected by the SLA to pro-  
vide the required protection when properly adjusted.  
STYLE “E”  
SPECIFICATIONS  
\\\  
n
1 Ø Low 83% of Nominal  
DROP-OUT  
VOLTAGE  
• Available up to 480 VAC  
• Delta or Wye Systems  
PROTECTS 3-PHASE  
EQUIPMENT AGAINST:  
3 Ø Low 90% of Nominal  
Models Up to 300 VAC  
Operate 250 mSEC  
Release 0.5 SEC  
• Phase Loss  
• Fixed, Lock Shaft, or  
Screwdriver Adjustment  
• Under Voltage  
• Phase Reversal  
RESPONSE TIMES  
STYLE “A” & “E”  
• Several Enclosure Styles  
Models Over 300 VAC  
Operate 1.0 SEC  
TYPICAL APPLICATIONS:  
• Air Handlers  
• Automatic Transfer Switching  
for Monitoring Emergency  
Power Supplies  
Release 2.0 SEC  
• Computer Power Protection  
• Conveyor Drive  
Operate 60 mSEC  
Release 0.5 SEC  
RESPONSE TIMES  
STYLE “N”  
• Irrigation Pumps  
• Lift Station Pumps  
• Robotics Equipment  
• Elevator Drives  
• Water Waste & Sewage  
Machinery  
Style “A” 3 VA (approx.)  
Models up to 300 VAC: 3 VA (max.)  
Style “E” Models over 300 VAC: 7 VA (max.)  
Models over 500 VAC: 3 VA (max.)  
• Oil & Gas Pumps  
POWER  
REQUIRED  
• Sawmill & Woodpump  
Machinery  
• Commercial/Industrial Air  
Conditioning & Refrigeration  
Compressors  
Style “N” 3 VA (max.)  
See Ordering Information  
Automatic (Manual Optional)  
• Power Substation  
OPERATING  
VOLTAGE  
MODEL NUMBER >>>>>> SLA  
Operating Voltage  
A
RESET  
See Ordering Information  
Glows when all conditions are Normal  
INDICATOR LED  
(On Applicable Models)  
Type of Operation  
Fixed  
Lock Shaft Adjusted  
Screwdriver Adjusted  
F
L
S
SPDT (style “A” and “N”)  
DPDT (style “E”)  
OUTPUT RATING  
PHASE  
SEQUENCE  
ABC (Will Not Operate CBA)  
Enclosure Style  
Octal Plug-In, Dust Cover  
A
Operate 32° to +131°F (0° to +55°C)  
Storage -49° to 185°F (-45° to +85°C)  
TEMPERATURE  
RATING  
Blade Plug-In, Dust Cover B  
Surface Mounted, #8 Screw Terminals  
E
Surface Mounted, 1/4" Quick Disconnect Terminals N  
Options  
U.S. PATENT  
NUMBER  
3,611,050  
Add R Suffix when manual reset is required,  
(available only in style “E” enclosure)  
Plug-In models are UL listed only when used with  
RB-08 relay socket.  
R
Style “A” NET: 2.24 oz Shipping: 2.56 oz  
Style “E” NET: 4.8 oz Shipping: 5.76 oz  
Style “N” NET: 5.3 oz Shipping: 5.6 oz  
WEIGHT  
U
215  
Diversified Electronics  
atcdiversified.com  
800.727.5646  
SLA Series  
Style “N”  
Style “E”  
Style “A”  
For UL Listed units, copper wire with 60°/75°C rating  
must be used for control circuitry connections.  
DIMENSIONS (INCHES)  
WIRING  
\\\  
\\\  
Style “A”  
Style “B”  
Style “A”  
Figure 1  
RB-08 or OT-08  
Figure 2  
RB-11  
Figure 3  
70-463-1  
2.375"  
1.75"  
Style B  
Style “E”  
Style “E”  
Figure 4  
Figure 5  
Style “N”  
Style “N”  
216  
800.727.5646  
atcdiversified.com  
Diversified Electronics  
SLA Series  
ORDERING INFORMATION  
\\\  
STYLE A PLUG-IN  
DROP-OUT VOLTAGE  
MODEL  
NUMBER  
OPERATING  
AGENCY  
APPROVAL  
TYPE OF  
VOLTAGE ADJUSTMENT 1 Ø LOW  
3 Ø LOW  
OUTPUT RATINGS  
DPDT, 345 VA Inductive; 10 Amps  
Resistive @ 240 VAC. Figure 2  
SPDT, 345 VA Inductive; 10 Amps  
Resistive @ 240 VAC, Figure 1  
SPDT, 345 VA Inductive; 10 Amps  
Resistive @ 240 VAC, Figure 3  
DPDT, 345 VA Inductive; 10 Amps  
Resistive @ 240 VAC, Figure 2  
SPDT, 345 VA Inductive; 10 Amps  
Resistive @ 240 VAC, Figure 1  
SPDT, 345 VA Inductive; 10 Amps  
Resistive @ 240 VAC, Figure 3  
SLA-120-ALA  
Lock Shaft  
SLA-120-ASA  
SLA-120-ASB  
SLA-230-ALA  
95-130 Adj  
79-108  
85-117  
Screwdriver  
Lock Shaft  
SLA-230-ASA 190-270 Adj.  
158-224  
171-243  
SLA-230-ASB  
Screwdriver  
SLA-380-ASA 350-440 Adj.  
SLA-440-ASA 430-480 Adj.  
290-365  
357-398  
315-396  
387-432  
SPDT, 360 VA Inductive; 10 Amps  
Resistive @ 240 VAC, Figure 1  
SUA-120-ALA  
95-130 Adj.  
SUA-120-ALAU*  
79-108  
85-117  
SPDT, 345 VA Inductive; 10 Amps  
Resistive @ 240 VAC, Figure 1  
Lock Shaft  
SUA-230-ALA  
190-270 Adj.  
SUA-230-ALAU*  
158-224  
171-243  
SUA-380-ASA 350-440 Adj.  
SUA-440-ASA 430-480 Adj.  
290-365  
357-398  
315-396  
387-432  
SPDT, 360 VA Inductive; 10 Amps  
Resistive @ 240 VAC, Figure 1  
Screwdriver  
*UL Listed only when used with RB-08 relay socket; 5 Amps Resistive @ 240 VAC. All voltages referenced on this page are phase-to-phase.  
Models also available with fixed operating voltages. Consult factory.  
STYLE E SURFACE MOUNTED ENCLOSURE  
DROP-OUT VOLTAGE  
MODEL  
NUMBER  
OPERATING  
VOLTAGE  
AGENCY  
APPROVAL  
1 Ø LOW  
3 Ø LOW  
RESET  
OUTPUT RATINGS  
DPDT, 211 VA Inductive; 10 Amps  
Resistive @ 120 VAC. Figure 4  
DPDT, 211 VA Inductive; 10 Amps  
Resistive @ 120 VAC. Figure 4  
DPDT, 345 VA Inductive; 5 Amps  
Resistive @ 240 VAC. Figure 4  
DPDT, 345 VA Inductive; 5 Amps  
Resistive @ 240 VAC. Figure 4  
DPDT, 360 VA Inductive; 3 Amps  
Resistive @ 600 VAC. Figure 4  
SPDT, 360 VA Inductive; 3 Amps  
Resistive @ 600 VAC. Figure 5  
DPDT, 360 VA Inductive; 3 Amps  
Resistive @ 600 VAC. Figure 4  
SPDT, 360 VA Inductive; 3 Amps  
Resistive @ 600 VAC. Figure 5  
DPDT, 360 VA Inductive; 3 Amps  
Resistive @ 600 VAC. Figure 4  
SLA-120-ALE  
SLA-120-ALER  
SLA-230-ALE  
SLA-230-ALER  
SLA-380-ALE  
SLA-380-ALER  
SLA-440-ALE  
SLA-440-ALER  
Automatic  
95-130 Adj.  
190-270 Adj.  
350-440 Adj.  
430-480 Adj.  
79-108  
85-117  
Manual  
Automatic  
Manual  
158-224  
290-365  
171-243  
315-396  
Automatic  
Manual  
Automatic  
Manual  
357-398  
436-519  
387-432  
473-563  
SLA-575-ALE 525-625 Adj.  
Automatic  
All voltage referenced are phase-to-phase.—Models also available with fixed operating voltages. Consult factory.  
STYLE N EPOXY ENCAPSULATED  
DROP-OUT VOLTAGE  
MODEL  
NUMBER  
SLA-120-AFN  
OPERATING  
VOLTAGE  
120  
AGENCY  
APPROVAL  
TYPE OF OPERATION  
1 Ø LOW  
3 Ø LOW  
Fixed  
100  
108  
SLA-208-AFN  
SLA-220-AFN  
SLA-240-AFN  
208  
220  
240  
Fixed  
Fixed  
Fixed  
173  
183  
199  
187  
198  
216  
All voltage referenced are phase-to-phase.  
217  

相关型号:

SLA-48VDC-SL-A

SIngle-component type 4 P
SONGLERELAY

SLA-48VDC-SL-B

SIngle-component type 4 P
SONGLERELAY

SLA-48VDC-SL-C

SIngle-component type 4 P
SONGLERELAY

SLA-560

High bright circular LED lamps (ヵ5.0mm)
ROHM

SLA-560JT3F

Single Color LED, Bright Red, Untinted Nondiffused, 5mm
ROHM

SLA-560JTTB7/XM

Single Color LED, Ultra Bright Red, Transparence Clear, 5mm
ROHM

SLA-560JTTE7/XK

Single Color LED, Ultra Bright Red, Transparent Clear, 5mm
ROHM

SLA-560JTTE7/XL

Single Color LED, Ultra Bright Red, Transparence Clear, 5mm
ROHM

SLA-560JTTE7/XM

Single Color LED, Ultra Bright Red, Transparent Clear, 5mm
ROHM

SLA-560JTTF7/XJ

Single Color LED, Ultra Bright Red, Transparence Clear, 5mm
ROHM

SLA-560JTTF7/XM

Single Color LED, Ultra Bright Red, Transparence Clear, 5mm
ROHM

SLA-560LT3F

High bright circular LED lamps (ヵ5.0mm)
ROHM