Electronic Twin Timer
TA8-TA
Multirange timer with independent on
and off times from 0.05 sec. to 60
hours each
ꢀ
ꢀ
ꢀ
Timing ranges 0.05 sec to 60 hours
16 timing ranges, front panel selectable
Indications for time range, output status
and power on
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
DPCO output relay
Easy-set dual concentric knob
Independent on/off time units
48-DIN
Plug-in octal base
Sockets available for panel, surface or
rail mounting
Year
Guarantee
ꢀ
Approved by standards: UL and CSA
Ordering code
T A 8 – TA 2 4 V A C / D C
T A 8 – TA 1 0 0 – 2 4 0 V A C
Specifications
Timing ranges (selectable)
Calibrated
timing range
0–6
Controlled timing range
Time unit: 0.1 sec.
0.05–0.6 sec.
0.1–1.2
Time unit: sec.
0.5–6 sec.
1–12
Time unit: min.
0.5–6 min.
1–12
Time unit: hrs.
0.5–6 hr.
1–12
0–12
0–30
0–60
0.25–3
0.5–6
2.5–30
5–60
2.5–30
5–60
2.5–30
5–60
Repeat accuracy
0.3ꢀ at maꢁ. setting time
Max. switching frequency
Allowable ambient temperature
Mechanical life
1800 times/hour
-10˚C to +55˚C (Avoid icing)
20 million operations or more
Electrical life
Allowable operating voltage range
Contact ratings
100,000 operations or more at 250 V AC 5A resistive load
0.85 to 1.1 times input voltage (0.9 to 1.1 at 55˚C)
5A at 250 V AC resistive load
Power consumption
Supply frequency
10VA at 240 V AC
50/60 Hz
2,000 V AC rms. 1 min. between current carrying part and non current carrying part
2,000 V AC rms. 1 min. between output contacts and control circuit
1,000 V AC rms. 1 min. between open contacts
Dielectric strength
Insulation resistance
Vibration
100 MΩ or more at 500 V DC megger
Mechanical durability: 10 to 55Hz, 0.75mm double amplitude
Malfunction durability: 10 to 55Hz, 0.5mm double amplitude
2
Mechanical durability: 500m/S (Approꢁ. 50G)
Shock
2
Malfunction durability: 100m/S (Approꢁ. 10G)
Telephone: +44 (0)208 452 6444
IMOnline: www.imopc.com
TA8-TA
Timing and wiring diagrams
TA8-A
Power
2-7
•
•
When power is applied, the NO timed contacts
make after the set time has elapsed.
1-3
T
Timed NO
Timed NC
LED POWER
LED OUTPUT
TA8-SA
Power
8-6
1-4
8-5
When power is removed the timer resets.
2-7
8-6
8-5
1-3
1-4
•
•
Timed contact
T
When power is applied, the NO contact makes
after the set time has elapsed.
When power is removed, the timer resets.
Instantaneous contact
Timed NO
Timed NC
Inst. NO
Inst. NC
When power is applied, the NO contact makes
instantly.
When power is removed, the timer resets.
LED POWER
LED OUTPUT
TA8-DA
•
When power (2-7) is ON, the NO timed contacts
(1-3, 8-6) are instantly closed. When power is
OFF, they are opened after the set time has
elapsed.
Power
2-7
Timed NO 1-3
8-6
Timed NC 1-4
8-5
TA8-TA
•
•
When power (2-7) is ON, the NO (1-3, 8-6) and
the NC (1-4, 8-5) timed contacts are alternately
closed to repeat the ON-OFF operations.
When power is OFF the timer resets.
Power
2-7
Timed NO
Timed NC
1-3
8-6
1-4
8-5
LED POWER
LED OUTPUT
Dimensions (mm)
Flush mounting
panel cut-out
Adaptor CTB
Net weight : Approꢁ. 15g
Note: For flush mounting, an adaptor CTB is required (sold separately).
When ordering, specify the adaptor type.
Net weight : Approꢁ. 100g
Sockets
Surface/track mounting – screw terminal
Flush mounting – screw terminal
STD-8
Net weight : Approꢁ. 40g
STF-8
Net weight : Approꢁ. 50g
Flush mounting – solder terminal
ZSV8
Telephone: +44 (0)208 452 6444
IMOnline: www.imopc.com
相关型号: