SYA14-032-C2 [ETC]
SICHERHEITSRELAIS SRB 320MM ; SICHERHEITSRELAIS SRB 320MM\n型号: | SYA14-032-C2 |
厂家: | ETC |
描述: | SICHERHEITSRELAIS SRB 320MM
|
文件: | 总10页 (文件大小:562K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Safety light curtain
FF-SYA Series
Compact, Universal, Smart and Full-featured
FEATURES
• Active Optoelectronic Protective Device
compliant with the requirements of the
IEC/EN 61496 - parts 1 and 2 European
norms for Type
4
electrosensitive
NRTL/C
protective equipment
• Meets applicable parts of North American
standards and regulations OSHA
1910.212 and 217; ANSI B11.1, 2 and 19;
RIA 15.06; CSA
• Self-contained unit. No electrical
connection necessary between emitter
and receiver
Approved as
Type 4
• 2 fail-safe static outputs with short-
circuit and cross-fault detection
per IEC/EN 61496-1/2
• Control of the infrared emission source
for cross-talk reduction
• Enhanced
diagnostic
information
includes: a signal strength indicator, a
cross-talk indicator and
diagnostic indicator
• Integrated DC to DC converter as
requested by the IEC/EN 61496 Standard
• Test input
a
failure
The new Honeywell FF-SYA light curtain is designed in compliance with
IEC/EN 61496 - parts 1 and 2 standard and meets the requirements for a Type 4
Active Optoelectronic Protective Device, the safest possible level for safety
products.
The product received an EC type test certificate from the French INRS notified body,
required for safety equipment as per the 98/37/EC Machinery Directive. It meets the
applicable parts of North American standards and regulations OSHA 1910.212,
ANSI and RIA 15.06 for Control Reliability and has a CSAnrtl/c mark, making it a
product usable in all parts of the world.
• Resolutions available:
ø14 mm/0.6 in for finger detection
ø30 mm/1.2 in for hand detection
ø60 mm/2.4 in for body detection
• Protection height up to 1830 mm/72 in
• Scanning range up to 20 m/65 ft
• Electrical connection: quick-disconnect
plugs
• Mounting brackets included
As soon as an object is detected inside the protection field, the FF-SYA opens its two
fail-safe static outputs to remove hazardous situation from the machine it controls.
The FF-SYA is a self-contained light curtain that does not require a separate control
unit for operation. The optional FF-SRS5939 interface control module is available to
provide higher current capability and additional functionality (see page 263). This
light curtain has been designed to satisfy the requirements of worldwide machine
manufacturers and users: its compact size combined with its universal and smart
features makes it full-featured and easy to use.
• Optional interface control module for
more switching capability or additional
features (see page 263).
APPLICATIONS
• Presses and punches
• Metal-forming, milling and drilling
machines
• Spot-welding machines and fine-boring
machines
• Pressing, moulding and thermoforming
machines
• Stacking machines, transporting and
conveyor technology; handling equipment
and assembly lines
!
WARNING
MISUSE OF DOCUMENTATION
•
The information presented in this product sheet (or catalogue) is for reference only. DO NOT USE this document as system
installation information.
Complete installation, operation and maintenance information is to be referenced for each product.
•
Failure to comply with these instructions could result in death or serious injury.
FF-SYA Series
• Industrial Safety Products •
79
The FF-SYA main features are:
- COMPACT SIZE
talk indicator flickers when emission from other systems is de-
tected, indicating that a different selection of the scanning
range is needed. The light curtain also has a signal strength
indicator which flickers if there is a slight misalignment of the
beams or front window contamination. Additional indicators
provide information on the outputs status, on the selected
scanning range and on failure diagnostic. Standard brackets
are delivered with the light curtain to ease the order process.
The housing has a T-slot mounting system to adapt brackets
anywhere along the housing. Quick disconnect connectors are
also delivered with the FF-SYA❏❏❏❏❏C2 light curtains.
The cross section of 42 x 55 mm2/1.65 x 2.16 in2 makes
installation possible in tight spaces, especially with the help of
the small brackets supplied with the light curtains. The optional
FF-SRS59392 interface control module easily fits inside the
machine control panel with its 45 mm/1.77 in width DIN rail
mount housing.
- UNIVERSAL
The housing dimensions are the same for the 14 mm/0.6 in,
30 mm/1.2 in, 60 mm/2.4 in resolution light curtains. The ex-
tended protected heights range from 334 to 1830 mm/ 13.1 to
72.0 in, covering all industrial applications. The scanning range
makes it possible to use mirrors in order to protect several sides
of a machine with only one system.
- FULL FEATURED
The FF-SYA does not need a galvanic insulated power supply
since it includes its own means of galvanic insulation (DC/DC
converter). Compliance with the installation requirements of the
IEC/EN 61496-1 standard is therefore guaranted by design. The
integrated test input can be used to test the entire safety chain.
When connected to the FF-SRS59392 interface control
module, the FF-SYA provides a wide variety of advanced
functions: cross-monitored relays, final switching devices
monitoring for the control of external contactors or relays,
choice between automatic restart or start and restart interlock
as well as relay status indicators.
- SMART
The FF-SYA is equipped with 2 fail-safe static outputs and an
optional full-featured safety control module is available for a
greater output current capability and manual restart functional-
ity. An integrated cross talk reduction system allows the scan-
ning range to be selected for the application distance. A cross
Cross-talk reduction system
The FF-SYA light curtain is based upon an infrared transmission between an emitter unit and a receiver unit. It is a requirement of
the IEC/pr EN 61496-2 standard that if a receiver R2 receives two signals transmitted by two different emitters E1 and E2, the
receiver R2 must turn to the alarm state. This happens if the receiver R2 is within the beam aperture angle and within the nominal
scanning range of the second emitter E1. The cross-talk detection indicator flickers on the receiver R2 to warn the installer.
R1
OFF
ON
R2
R3
alarm
test
Front
cover
E
1
R
1
E
1
100 % of the nominal
scanning range
R
2
E
2
R
2
(Factory setting)
A selector switch is available on the emitter units for the selection of the adequate emission power. This switch can be used to
eliminate this cross-talk phenomenon by decreasing the nominal scanning range down to 42 % or 54 % of its value. The front cover
is accessible and there is no need to remove unit from the machinery to select a different scanning range.
OFF
ON
R1
R2
R3
alarm
test
R
1
E
1
E
1
R
2
R
2
E
2
54 % of the nominal
scanning range
80
• Industrial Safety Products •
FF-SYA Series
LED status indicators
Emitter
R3 R2 R1
100 % of nominal scanning range
54 % of nominal scanning range
42 % of nominal scanning range
R1
Scanning range indicators (yellow)
R2
R3
Alarm indicator (red)
Test indicator (red)
Alarm
Alarm
Normal
operation
Device failure
Test
Test
Normal
operation
Device in test mode
Scanning range selection:
E
R
2.5 m / 8.3 ft
8.4 m / 27 ft
3.25 m / 10.7 ft
10.8 m / 35 ft
6 m / 20 ft
FF-SYA14
0
FF-SYA30 &
FF-SYA60
20 m / 65 ft
42 %
54 %
100 %
Receiver
OFF ON
OFF ON
Outputs are open
Outputs are closed
Operation indicators (red and green)
Signal strength indicator (yellow)
Cross-talk indicator (red)
Perfect beam Slight beam
Total beam
alignment misalignment misalignment
No cross-talk detected
Cross-talk detected
Light OFF
Light ON
Flickering light
FF-SYA Series
• Industrial Safety Products •
81
FF-SYA
• Type 4 according to the IEC/EN 61496 - parts 1 and 2 standards
• Control of the infrared emission source for cross-talk reduction
• 2 fail-safe static outputs with short-circuit and cross-fault detection
• Enhanced diagnostic information
NRTL/C
Approved as
Type 4
per IEC/EN 61496-1/2
Dimensions in millimeters / inches, meters / feet, weights in kg / lbs
SYA14
ø 14 / 0.6
SYA30
ø 30 / 1.2
See Table 2
0,6 to 20 / 2 to 65
24 Vdc (± 15 %)
SYA60
ø 60 / 2.4
Features
Type
Resolutions (mm/in.)
Protection heights (mm/in.)
Nominal scanning ranges (m/ft)
Supply voltage
0 to 6 / 0 to 20
0,6 to 20 / 2 to 65
Emitter: 7 W max. / Receiver: 5.5 W max. (see Table 2)
2 fail-safe static outputs (switching capacity: 0.5 A / 24 Vdc)
13.5 to 22.5 ms (see Table 2)
Power consumption
Outputs
Response time
Test input (external normally closed contact)
Function
Emitter: test mode, failure alarm, selected scanning range
Receiver: outputs status, optical signal margin, cross-talk detection
W 42 x D 55 mm2/W 1.65 x D 2.16 in.2 (see Tables 1 and 2 for complete housing dimensions)
Infrared modulated light source (880 nm)
LED status indicators
Cross sectional area
Emission
± 2°, ± 25 % (in compliance with the IEC/EN 61496 - part 2)
Sun: 20 000 lux / Lamp: 15 000 lux
Effective aperture angle
Light immunity
IEC 61000-4-4: level III / IEC 61000-4-3: level III
Electrical noise immunity
Ambient temperature
Vibrations
Operating temperature: 0 to 55 °C/32 to 131 °F / Storage temperature: -20 to 75 °C/-4 to 167 °F
IEC/EN 61496-1: 10 to 55 Hz frequency range, 1 octave/min.sweep rate, 0.35 mm ± 0.05
amplitude, 20 sweeps per axis, for 3 axes
IP 65, NEMA 4, 13
Sealing
Material
Housing: aluminium alloy, front plate: polymethyl metacrylate (PMMA), end caps: polycarbonate
Electrical connection
FF-SYA❏❏❏❏❏C2: DIN 43651 plastic 7-pin right-angle plugs with crimping contacts
(Hirschmann N6RFF type) / FF-SYA❏❏❏❏❏Q2: 5 & 7 pole straight male receptacles
compatible with Brad Harrison mini-change plugs (not included) (4)
Dimensions (mm/in)
Ordering information
Each listing consists of an emitter, a receiver, a pair
of connectors, 2 pairs of right-angle brackets,
2 pairs of straight brackets and a test rod.
ø R
31 / 1.22
Pg 11
FF-SYAqq qqq q2
C: DIN 43651
plastic plugs included
Q: male receptacles
compatible with Brad
Harrison mini-change
plugs (not included)(4)
Model (see Table 2)
Resolutions
42 / 1.65
60 / 2.36
54.2 / 2.13
14: ø 14 mm / 0.6 in
30: ø 30 mm / 1.2 in
60: ø 60 mm / 2.4 in
(1) Protection Height for the minimum detected
object size or resolution
(2) Sensing Field Height (full screen height)
(3) Total Height (including plugs for the
FF-SYAqqqqqC2 versions and male
receptacles only for the FF-SYAqqqqqQ2)
(4) See accessories
(leave enough room to
insert a screw-driver)
33 / 1.30
86.5 / 3.40
Table 1 (mm/in)
FF-SYA14
øR (resolution)
ø 14 / 0.6
ø 30 / 1.2
P (lens pitch)
D (lens diameter)
4 / 0.16
A (inactive zone)
B (inactive zone)
90.6 / 3.56
10 / 0.4
20 / 0.8
40 / 1.6
15.2 / 0.60
22.2 / 0.87
42.2 / 1.66
FF-SYA30
FF-SYA60
10 / 0.4
10 / 0.4
87.6 / 3.45
87.6 / 3.45
ø 60 / 2.4
82
• Industrial Safety Products •
FF-SYA Series
Table 2
Model
032
048
064
080
096
112
128
144
-
160
-
176
-
Protection height (mm/in) (1)
SYA14 334/13.1 494/19.4 654/25.7 814/32.07 974/38.3 1134/44.6 1294/50.9
SYA30 350/13.7 510/20.09 670/26.3 830/32.7 990/39 1150/45.3 1310/51.6 1470/57.9 1630/64.2 1790/70.5
SYA60 390/15.3 550/21.6 710/27.9 870/34.2 1030/40.5 1190/46.8 1350/53.1 1510/59.4 1670/65.7 1830/72
Sensing field height (mm/in)
(2) SYA14 314/12.3 474/18.6 634/24.9 794/31.2 954/37.5 1114/43.8 1274/50.1
-
-
-
SYA30 310/12.2 470/18.5 630/24.8 790/31.1 950/37.4 1110/43.7 1270/50.03 1430/56.3 1590/62.6 1750/68.9
SYA60 290/11.4 450/17.7 610/24.03 770/30.3 930/36.6 1090/42.9 1250/49.2 1410/55.1 1570/61.8 1730/68.1
Total height (mm/in) (3)
FF-SYA❏❏❏❏❏C2 483/19 643/25.3 803/31.6 963/37.9 1123/44.2 1283/50.5 1443/56.8 1603/63.1 1763/69.4 1923/75.7
FF-SYA❏❏❏❏❏Q2 443/17.4 603/23.7 763/30 923/36.3 1083/42.6 1243/48.9 1403/55.2 1563/61.5 1723/67.8 1883/74.1
Response time (msec)
SYA14
14
13.5
13.5
15
14
14
15.5
14
14
17.5
14.5
14.5
19.5
15
15
20.5
15
15
22.5
15.5
15.5
-
16
16
-
-
SYA30
SYA60
17.5
17.5
17.5
17.5
Weight per device (kg/lbs)
Powerconsumption (W) SYA14
1/2.2 1.38/3.04 1.76/3.88 2.14/4.71 2.52/5.55 2.90/6.39 3.28/7.23 3.66/8.07 4.04/8.9 4.42/9.74
5/3.5
5/4
4/3.5
4/3.5
6/4
5/4
5/3.5
6/4.5
5/4
5/4
6/5
5/4
5/4
7/5
6/4
6/4
7/5.5
6/4.5
6/4
-
-
(Emitter/receiver)
SYA30 4/3.5
SYA60 4/3.5
Preferred listings in bold
6/4.5
6/4.5
6/4.5
6/4.5
6/4.5
6/4.5
Safety distances (in mm, 100 mm = 3.9 in)
European EN 999 standard
Normal approach
SYA14
SYA30
SYA60
S ³ 2000 (t1 + t2),
with S ³ 100
S ³ 2000 (t1 + t2) + 128,
with S ³ 100
S ³ 1600 (t1 + t2) + 850,
with Hu ³ 900
HI £ 300 m
If S ³ 500, then use:
S ³ 1600 (t1 + t2),
with S ³ 500
If S ³ 500, then use:
S ³ 1600 (t1 + t2) + 128,
with S ³ 500
Parallel approach
Angled approach
With:
S ³ 1600 (t1+ t2) + 1200 - 0.4 H), with H £ 875 or
S ³ 1600 (t1+ t2) + 850, with 875 £ H £ 1000
with H ³ 15 (R-50) where R is the light curtain resolution
(with H ³ 150 for the FF-SYA60 light curtain)
if a ³ 30°, then use one of the formula given for a normal approach,
with Hu ³ 900 and Hl £ 300 for the FF-SYA60 light curtain
if a £ 30°, then use one of the formula given for a parallel approach,
with Hu £ 1000 and Hl ³ 15 (R-50) where R is the light curtain resolution
(with Hl ³ 150 for the FF-SYA60 light curtain)
S
minimum safety distance (in mm, 100 mm = 3.9 in)
t1 light curtain response time (in sec.)
t2 machine stopping time (in sec.)
H
height of the detection plane above the reference floor (in mm, 100 mm = 3.9 in)
Hu height of the uppermost beam above the reference floor (in mm, 100 mm = 3.9 in)
Hl height of the lowest beam above the reference floor ( in mm, 100 mm = 3.9 in)
For more information, refer to the EN 999 European standard or comply with the requirements on safety distances given by the type C European
standard if existing for the considered machine.
FF-SYA Series
• Industrial Safety Products •
83
Safety distances (in inches, 1 in = 25,4 mm)
US ANSI / OSHA standard
SYA14
SYA30
SYA60
Normal approach
DS
DS ³ 63 (t1 + t2) + 0.94
DS ³ 63 (t1 + t2) + 3.08
DS ³ 63 (t1 + t2) + 33.46
With:
DS minimum safety distance (in inches, 1 in. = 25.4 mm)
t1 light curtain response time (in sec.)
t2 machine stopping time (in sec.)
For more information, refer to the US regulations and standards (OSHA 29 CFR 1910.212 and 1910.217, ANSI B11.1, B11.2, B11.19 and ANSI/
RIA R15.06).
Wiring diagram (using the FF-SRS59392 safety control module)
The FF-SRS5939 interface control module is set in the Manual restart mode without FSD monitoring:
(DC+)
Phase
(DC+)
1.5 A max
Fuse
1A Fuse
1A Fuse
Fuse
Fuse
NO
P/B
3
A1(+) S33 S34/Y1
Y2
13
23
31
1
1
FF-SYA
FF-SYA
emitter
X2
X1
X3
FF-SRS59392
relay module
4 (+)
5 (-)
receiver
Signalling
contact
Optional test
input
(or jumpered)
K1
K2
internal
fuse
(1)
(1)
A2(-)
S12 S22
14
24
32
Dual channel
2
2
6
4
5
machine control circuit
(recommended circuit)
Emergency stop
Push-button
Neutral
(DC-)
(DC-)
(1) Use pin 3 for the FF-SYA❏❏❏❏❏Q2E emitter and pin 7 for the FF-SYA❏❏❏❏❏Q2R receiver
OSSD1 and OSSD2: Output Signal Switching Devices (light curtain safety contacts)
N.O. P/B: normally open contact of a push-button
Notice
Improper use of the FF-SYA light curtain
The cross-monitoring of the FF-SYA static outputs is based upon a self-checking principle which guarantees the detection of an output short-
circuit and the detection of a short-circuit between the outputs (cross-fault detection). The FF-SRS5939 interface control module is primarily
designed to be interfaced with Honeywell fail-safe static outputs devices.
Compatibility of the FF-SYA with any other emergency stop safety control module is not guaranteed.
84
• Industrial Safety Products •
FF-SYA Series
(DC+)
1A Fuse
1A Fuse
1.A Fuse
NO P/B
Dual channel
machine control circuit
K1
Phase
1
1
2
3
(DC+)
Fuse Fuse
4 (+)
K3
Optional test
input
(or jumpered)
K1
K3
K2
K3
K2
FF-SYA
emitter
FF-SYA
(1)
(1)
receiver
5 (-)
2
4
5
6
Neutral
(DC-)
K3 K2
K3 K1
(2)
(2)
(2)
K3
K2
FSD
K1
FSD
(DC-)
Wiring diagram (using external safety relays with guided contacts)
This interface provides the manual restart and the FSD monitoring:
(1) Use pin 3 for the FF-SYA❏❏❏❏❏Q2E emitter and pin 7 for the FF-SYA❏❏❏❏❏Q2R receiver
(2) 31 Vdc varistors (customer supplied)
OSSD1 and OSSD2: Output Signal Switching Devices (light curtain safety contacts)
FSD: Final Switching Devices (safety relays with guided contacts)
N.O. P/B: normally open contact of a push-button
FF-SYA Series
• Industrial Safety Products •
85
Accessories
FF-SYZ001001
Kit of 2 right-angle brackets and 2 straight brackets with screws, nuts and bolts. Order 2 kits for a
complete set emitter and receiver (already included in the FF-SYA package).
PROTECTION AGAINST HIGH VIBRATIONS
In case of high vibrations, 3 pairs of brackets must be used for light curtain systems with protection heights
greater or equal to 1000 mm/39.4 in (An additional bracket kit must be ordered).
45 / 1.77
ø4,5 / 0.18
8 / 0.31
45˚
ø 4 / 0.16
18 / 0.71
12,5 / 0.49
24 / 0.94
6,6 / 0.26
7 / 0.27
2,5 / 0.10
4,5 / 0.18
ø 6,5 / 0.25
20 /
0.78
30 / 1.18
Right-angle bracket
Straight bracket
FF-SYZ003001
Kit of 2 adjustable brackets with screws, nuts and bolts. Order 2 kits for a complete set for emitter and receiver.
To be ordered separately as an option.
PROTECTION AGAINST HIGH VIBRATIONS
In case of high vibrations, 3 pairs of brackets must be used for light curtain systems with protection heights
greater or equal to 1000 mm/39.4 in (An additional bracket kit must be ordered).
2.5 / 0.098
7.0 / 0.275
38.0 / 1.496
23.0 / 0.905
12.5 / 0.492
R 10.5 / 0.413
19.5 / 0.767
86
• Industrial Safety Products •
FF-SYA Series
Plugs kits
FF-SYZ172113 (for FF-SYA❏❏❏❏❏C2 light curtains)
Kit of 2 DIN 43651 plastic 7-pin right-angle plugs with crimping contacts (Hirschmann,
N6RFF type). Order 1 kit for a complete set emitter and receiver.
Already included in the FF-SYA package.
FF-SYZ172159 (for FF-SYA❏❏❏❏❏C2 light curtains)
Kit of 2 DIN 43651 plastic 7-pin straight plugs with crimping contacts (Hirschmann, N6REF
type). Order 1 kit for a complete set emitter and receiver.
To be ordered separately as an option.
41308 (for FF-SYA❏❏❏❏❏Q2E emitters)
5-pole female straight Brad Harrison Mini-change plug 3.66 m (12 ft) cable length. Order
one plug for the emitter.
1-White
2-Red
1
5
To be ordered separately when using the FF-SYA
Q2 light curtains.
4
2
3-Green
4-Orange
3
41322 (for FF-SYA❏❏❏❏❏Q2E emitters)
5-pole female straight Brad Harrison Mini-change plug, 6.10 m (20 ft) cable length. Order
one plug for the emitter.
Face view
male
5-Black
To be ordered separately when using the FF-SYA
Q2 light curtains.
42803 (for FF-SYA❏❏❏❏❏Q2R receivers)
7-pole female straight Brad Harrison Mini-change plug, 3.66 m (12 ft) cable length. Order
one plug for the receiver.
1-White/Black
2-Black
1
3
6
4
3-White
To be ordered separately when using the FF-SYA
Q2 light curtains.
7
2
5
4-Red
5-Orange
42821 (for FF-SYA❏❏❏❏❏Q2R receivers)
7-pole female straight Brad Harrison Mini-change plug, 6.10 m (20 ft)cable length. Order
one plug for the receiver.
Face view 6-Blue
male
7-Green
To be ordered separately when using the FF-SYA
Q2 light curtains.
Test rods
FF-SYZROD14
Test rod for ø14 mm/0.6 in. resolution safety light curtains
Already included in the FF-SYA package.
FF-SBZROD30
Test rod for ø30 mm/1.2 in. resolution safety light curtains
Already included in the FF-SYA package.
Safety control module
AC to DC power supply
FF-SRS59392
Interface control module designed for failsafe static outputs safety light curtains (24 Vdc)
To be ordered separately as an option.
FF-SYZ880246
Lambda Coutant JWS50 - 24 A type AC/DC power supply
Input voltage: 85 to 265 Vac
Output voltage: 24 Vdc / 2.2 A (50 W)
Dimensions: 159 x 85 x 37 mm/6.26 x 3.34 x 1.45 in.
Mounting: three M3 screws or DIN RAIL adapter (see below)
Approvals: UL 1950, CSA 950, EN 60950
To be ordered separately as an option.
FF-SYZ736048
DIN RAIL adapter for Lambda Coutant JWS50 power supply
To be ordered separately as an option.
FF-SYA Series
• Industrial Safety Products •
87
FF-SYZFL
(for FF-SYA30
2 and FF-SYA60
2 only)
Welding protection kit including two adhesive tapes to be glued on the front
windows of the FF-SYA30or FF-SYA60 light curtain.
Make sure the transparent protection tape is on the emitter and the filtered protection is glued on
the receiver. Protections cannot be removed without damaging the device.
Features:
Storage and operating temperatures:
-20° to 55°C / -4° to 131°F, high resistance to the ejection of melting particules
Material:
Prohibited liquids:
Organic glass
Sulfuric acid, hydrofluoric acid, ammonia solution
Scanning range attenuation:
Optical immunity improvement factor:
36%
2,5
Protection heights of FF-SYA30 or FF-SYA60:
Ordering guide:
Model 048
Model 064
Model 080
Model 096
FF-SYZFL048
FF-SYZFL064
FF-SYZFL080
FF-SYZFL096
FF-SYA Series
88
• Industrial Safety Products •
相关型号: