Symbios® SYM20810  
PCI to SCSI  
Host Adapter  
User’s Guide  
Version 1.1  
®
Order Number S14037  
Electromagnetic Compatibility Notices  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  
1. This device may not cause harmful interference, and  
2. This device must accept any interference received, including interference that may cause undesired operation.  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15  
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a  
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed  
and used in accordance with the instructions, may cause harmful interference to radio communications. However,  
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful  
interference to radio or television reception, which can be determined by turning the equipment off and on, the user  
is encouraged to try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and the receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product. LSI  
Logic is not responsible for any radio or television interference caused by unauthorized modification of this equipment  
or the substitution or attachment of connecting cables and equipment other than those specified by LSI Logic. The  
correction of interferences caused by such unauthorized modification, substitution, or attachment will be the  
responsibility of the user.  
The LSI Logic Symbios SYM20810 is tested to comply with FCC standards for home or office use.  
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.  
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du  
Canada.  
This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information  
Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may  
cause radio interference. Install and use the equipment according to the instruction manual.  
LSI Logic Corporation  
North American Headquarters  
Milpitas, CA  
408.433.8000  
ii  
This document contains proprietary information of LSI Logic Corporation. The  
information contained herein is not to be used by or disclosed to third parties  
without the express written permission of an officer of LSI Logic Corporation.  
LSI Logic products are not intended for use in life-support appliances, devices,  
or systems. Use of any LSI Logic product in such applications without written  
consent of the appropriate LSI Logic officer is prohibited.  
Document DB15-000134-00, Second Edition (December 1999)  
This document describes Version 1.1 of LSI Logic Corporation’s SYM20810 PCI  
to SCSI Host Adapter and will remain the official reference source for all  
revisions/releases of this product until rescinded by an update.  
To receive product literature, visit us at http://www.lsilogic.com  
LSI Logic Corporation reserves the right to make changes to any products herein  
at any time without notice. LSI Logic does not assume any responsibility or  
liability arising out of the application or use of any product described herein,  
except as expressly agreed to in writing by LSI Logic; nor does the purchase or  
use of a product from LSI Logic convey a license under any patent rights,  
copyrights, trademark rights, or any other of the intellectual property rights of LSI  
Logic or third parties.  
Copyright © 1997–1999 by LSI Logic Corporation. All rights reserved.  
TRADEMARK ACKNOWLEDGMENT  
LSI Logic logo design and Symbios are registered trademarks and SDMS is a  
trademark of LSI Logic Corporation.  
SR  
iii  
iv  
Contents  
Preface  
Chapter 1  
What is Covered in this Guide  
1.1  
1.2  
Installation  
1-3  
1-5  
Connecting Internal SCSI Devices  
1.2.1  
1.2.2  
1.2.3  
1.2.4  
Completing the Installation  
Connecting External SCSI Devices  
SCSI Bus Termination  
1-7  
1-7  
1-9  
Setting SCSI IDs  
1-11  
1-12  
1-12  
1-12  
1-13  
1-14  
1.3  
1.4  
Installing the Host Adapter Device Driver Software  
1.3.1  
1.3.2  
1.3.3  
DOS/Windows  
Windows 95/Windows NT  
OS/2  
Troubleshooting  
Customer Feedback  
Figures  
1.1  
1.2  
1.3  
1.4  
1.5  
SYM20810 Board Outline  
1-2  
1-4  
Inserting the Host Adapter  
Internal SCSI Devices Chained Together  
Multiple External Devices Chained Together  
SCSI Bus Termination  
1-6  
1-8  
1-10  
Contents  
v
vi  
Contents  
Preface  
This book is the primary reference and User’s Guide for the LSI Logic  
Symbios SYM20810 PCI to SCSI Host Adapter. It contains a complete  
functional description for the SYM20810 and includes complete physical  
and electrical specifications for the SYM20810.  
Audience  
This document assumes that you have some familiarity with  
microprocessors and related support devices. The people who benefit  
from this book are:  
Engineers and managers who are evaluating the processor for  
possible use in a system  
Engineers who are designing the processor into a system  
Related Publications  
Symbios PCI SCSI Device Management System SDMS 4.0 User’s  
Guide, LSI Logic Corporation, Order Number S14007  
Revision Record  
Revision Date  
Remarks  
1.0  
1.1  
9/97  
First official release.  
12/99  
Miscellaneous cosmetic/format changes from Symbios to LSI Logic.  
Preface  
vii  
viii  
Preface  
Chapter 1  
What is Covered in this  
Guide  
This installation guide provides instructions and illustrations to help you  
install a Symbios SYM20810 PCI to SCSI host adapter. It covers the  
following topics:  
Section 1.1, “Installation”  
Section 1.2, “Connecting Internal SCSI Devices”  
Section 1.3, “Installing the Host Adapter Device Driver Software”  
Section 1.4, “Troubleshooting”  
The SYM20810 provides a low-cost SCSI solution for attaching SCSI  
devices (disk drives, scanners, CD-ROM drives, tape drives, removable  
media drives, etc.) to PCI computer systems with an ISA/EISA bracket  
type. Figure 1.1 shows the major components and connections of the  
SYM20810 host adapter.  
The Symbios SCSI Device Management System (SDMS™) software  
includes drivers and utilities for operating this host adapter in computers  
running DOS/Windows, Windows 95, Windows NT, and OS/2.  
Symbios SYM20810 PCI to SCSI Host Adapter  
1-1  
Figure 1.1 SYM20810 Board Outline  
Internal  
SCSI Interface  
J2  
P1  
External  
SCSI Interface  
J3  
SYM2081x, J1 to  
PCI Mainboard  
1-2  
What is Covered in this Guide  
1.1 Installation  
Step 1. Before you begin the installation, switch off the power to the  
computer and any peripheral devices and disconnect all power  
cords.  
Caution:  
Before handling the SYM20810 board, ground yourself  
using a ground strap attached to the computer metal frame.  
Static charges on your body can damage electronic  
components. Handle plug-in boards by the edge; do not  
touch board components or gold connector contacts.  
Step 2. Remove the cover on your computer to access the PCI slots.  
Refer to your computer documentation if necessary.  
Step 3. Locate an unused expansion slot for installing the PCI to SCSI  
host adapter. Refer to your computer documentation if  
necessary to locate the expansion slots.  
Step 4. Remove the blank bracket panel on the back of the computer  
that covers the slot you intend to use. Save the bracket screw.  
Step 5. Remove the SYM20810 host adapter board from the antistatic  
bag and insert the edge connector into the PCI slot, as pictured  
in Figure 1.2. Make sure the edge connector is properly aligned  
before pressing the board into place. Apply even pressure to  
both ends of the board while inserting it.  
Installation  
1-3  
Figure 1.2 Inserting the Host Adapter  
Bracket Screw  
1-4  
What is Covered in this Guide  
1.2 Connecting Internal SCSI Devices  
Step 1. If you are connecting an internal SCSI device, plug the 50-pin  
connector cable on one end of the internal SCSI ribbon cable  
into the connector J2 (see Figure 1.3). The ribbon cable  
included in your SYM20810 host adapter kit is keyed to assure  
that it can be easily connected.  
Step 2. Plug the 50-pin connector on the other end of the ribbon cable  
into the SCSI connector on your internal SCSI device.  
Step 3. To attach more than one internal device, use a SCSI ribbon  
cable with the required number of 50-pin connectors attached  
along its length. Plug the cable connectors into the internal  
SCSI device connectors, as illustrated in Figure 1.3.  
Step 4. Terminate the SCSI bus as described in the Section 1.2.3,  
“SCSI Bus Termination,page 1-9.  
Step 5. Make any required power connections to your internal SCSI  
device(s).  
Connecting Internal SCSI Devices  
1-5  
Figure 1.3 Internal SCSI Devices Chained Together  
J2  
1-6  
What is Covered in this Guide  
1.2.1 Completing the Installation  
Step 1. The bracket around the end connector (J3) should fit where the  
blank bracket panel was removed. Secure the bracket with the  
bracket screw.  
Step 2. Replace the cover as described in your computer  
documentation.  
1.2.2 Connecting External SCSI Devices  
Step 1. If you need to connect external SCSI devices to the SYM20810  
host adapter, plug the 50-pin connector on one end of a  
shielded external SCSI cable into the host adapter SCSI  
connector J3. This connector is now bracketed to the back  
panel of your computer. Figure 1.4 shows how this connection  
is made.  
Step 2. Plug the 50-pin connector on the other end of the SCSI cable  
into the SCSI connector on the peripheral device. This  
connection is shown in Figure 1.4.  
Step 3. If you wish to connect more than one device to the host  
adapter, use shielded cables to chain them together as  
illustrated in Figure 1.4.  
Step 4. Terminate the SCSI bus as described in the section Section  
1.2.3, “SCSI Bus Termination,page 1-9.  
Connecting Internal SCSI Devices  
1-7  
Figure 1.4 Multiple External Devices Chained Together  
1-8  
What is Covered in this Guide  
1.2.3 SCSI Bus Termination  
All SCSI devices have a set of resistors called terminators to assure  
reliable operation of the SCSI bus. The first and last physical devices on  
the SCSI bus must have these terminators enabled; all other SCSI  
devices on the bus must have their terminators removed or disabled.  
Termination on the SYM20810 host adapter is automatically enabled  
when it is connected to the end of the bus. Refer to the SCSI device  
documentation for information on how to identify and change the  
terminator setting on each SCSI peripheral device.  
Connecting Internal SCSI Devices  
1-9  
Figure 1.5 SCSI Bus Termination  
Last Device  
on Chain  
Termination  
Enabled  
Host Adapter  
Termination  
Automatically  
Disabled  
Does Not  
End Chain  
Termination  
Disabled  
Last Device  
on Chain  
Termination  
Enabled  
1-10  
What is Covered in this Guide  
1.2.4 Setting SCSI IDs  
Each device on the SCSI bus, including the host adapter, must have a  
unique SCSI ID from 0 through 7. Refer to your peripheral device  
documentation for instructions on how to determine and change the ID  
of each peripheral device. The SCSI ID on the SYM20810 is 7.  
Caution:  
The SYM20810 host adapter supports only Single-Ended  
(SE) SCSI devices. Differential SCSI devices may be  
damaged if you connect them to this host adapter. Refer to  
your SCSI device documentation to make sure you are  
connecting a SE device.  
Connecting Internal SCSI Devices  
1-11  
1.3 Installing the Host Adapter Device Driver Software  
The SYM20810 is supported by Symbios SDMS drivers for  
DOS/Windows 3.x, Windows 95, Windows NT, and OS/2. Consult the  
software documentation for complete installation instructions. The  
Symbios SDMS driver/utility software and documentation for your  
operating system can be downloaded from the LSI Logic web site  
(www.lsilogic.com).  
1.3.1 DOS/Windows  
The Symbios SDMS driver for DOS runs under DOS 5.0 and above and  
all versions of Windows 3.x. Consult the software documentation  
(dos.txt) for specific installation instructions and descriptions of the  
DOS/Windows 3.x drivers and utilities. Symbios SDMS software also  
includes the following DOS/Windows utilities:  
DOS Installation Utility  
SCSI Low Level Format Utility  
Verify Utility  
SCSI Configuration Utility  
1.3.2 Windows 95/Windows NT  
Windows 95 and Windows NT (versions 3.51 and newer) have  
embedded support for the SYM20810, so the driver is installed  
automatically during setup. To add the SYM20810 to an existing system,  
install the board according to the instructions in this guide, then restart  
the computer. The operating system will automatically launch the “Add  
New Hardware” wizard to install the driver. Follow these steps to make  
sure that the driver software has been properly installed:  
Step 1. From the Windows 95 Start menu, select Settings, then Control  
Panel.  
Step 2. From the Control Panel window, click the System icon. The  
System Properties menu displays.  
Step 3. Select the Device Manager.  
Step 4. Click on the SCSI Controllers icon.  
1-12  
What is Covered in this Guide  
Step 5. The name of the driver for the SYM20810 is “Symbios  
8100ASP, 2081x PCI SCSI Adapter; 53C810A Device.If  
this driver is not listed, follow the instructions in the Symbios  
SDMS Windows 95 or Windows NT driver documentation. This  
documentation can be found on the LSI Logic web site at  
www.lsilogic.com.  
Step 6. If there are no red X’s or yellow question mark icons next to the  
listing for the SYM20810, the driver is loaded and ready to use.  
Please keep in mind that Windows NT only displays the driver  
information, not every controller found by the driver.  
For information on how to change the Symbios driver in your system or  
to add a driver to a Windows 95 or Windows NT system that is set up  
with a different SCSI driver, refer to the LSI Logic Symbios PCI SCSI  
Device Management System SDMS 4.0 User’s Guide or the software  
documentation that accompanies the driver on your diskette or on the LSI  
Logic web site. The file names are 95.txt for Windows 95 and  
8xxnt.txt for Windows NT.  
1.3.3 OS/2  
The Symbios SYM8XX.ADD device driver complies with the IBM OS/2  
Adapter Device Driver specification, and works with third party  
applications that comply with the same specification. For complete  
installation instructions, refer to the OS2.txt file supplied with your  
Symbios OS/2 SCSI driver software. The latest version of this driver and  
the text file may also be found on the LSI Logic web site at  
www.lsilogic.com.  
Installing the Host Adapter Device Driver Software  
1-13  
1.4 Troubleshooting  
During installation, no SCSI devices are found:  
Check the cable connections and the host bus adapter installation.  
Ensure that all devices are powered on and terminated correctly.  
Check that no devices have duplicate SCSI IDs.  
Make sure INT A is assigned for the PCI slot(s) where your SCSI  
host adapter(s) are installed.  
Make sure the SCSI device driver is installed properly.  
The computer hangs or locks up when booting and the SCSI devices  
attached are not seen by the computer system:  
Make sure that all the SCSI devices are configured at different ID  
numbers (the boot drive should have the lowest ID).  
Make sure both ends, but only the ends, of the SCSI bus are  
terminated.  
(DOS, OS/2) Make sure the device driver is listed in CONFIG.SYS  
(and loaded when booting).  
The device driver does not see one of the SCSI devices:  
Reboot the computer.  
Make sure the SCSI devices have different ID numbers (the boot  
drive should have the lowest ID).  
Make sure both ends, but only the ends, of the SCSI bus are  
terminated.  
Check the cable and power connections.  
1-14  
What is Covered in this Guide  
Customer Feedback  
We would appreciate your feedback on this document. Please copy the  
following page, add your comments, and fax it to us at the number  
shown.  
If appropriate, please also fax copies of any marked-up pages from this  
document.  
Important: Please include your name, phone number, fax number, and  
company address so that we may contact you directly for  
clarification or additional information.  
Thank you for your help in improving the quality of our documents.  
Reader’s Comments  
Fax your comments to:  
LSI Logic Corporation  
Technical Publications  
M/S E-198  
Fax: 408.433.4333  
®
Please tell us how you rate this document: Symbios SYM20810 PCI to  
SCSI Host Adapter User’s Guide. Place a check mark in the appropriate  
blank for each category.  
Excellent Good Average Fair  
Poor  
____  
____  
____  
____  
____  
Completeness of information  
Clarity of information  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
Ease of finding information  
Technical content  
Usefulness of examples and  
illustrations  
Overall manual  
____  
____  
____  
____  
____  
What could we do to improve this document?  
If you found errors in this document, please specify the error and page  
number. If appropriate, please fax a marked-up copy of the page(s).  
Please complete the information below so that we may contact you  
directly for clarification or additional information.  
Name  
Date  
Telephone  
Title  
Fax  
Department  
Company Name  
Street  
Mail Stop  
City, State, Zip  
Customer Feedback  
U.S. Distributors  
by State  
A. E.  
Avnet Electronics  
Colorado  
Denver  
Indiana  
Fort Wayne  
I. E.  
W. E. Tel: 888.358.9953  
Indianapolis  
A. E.  
Minnesota  
Champlin  
http://www.hh.avnet.com  
B. M.  
Bell Microproducts,  
Inc. (for HAB’s)  
A. E.  
B. M.  
Tel: 303.790.1662  
Tel: 303.846.3065  
Tel: 219.436.4250  
B. M.  
Tel: 800.557.2566  
Eden Prairie  
http://www.bellmicro.com  
I. E.  
http://www.insight-electronics.com  
W. E. Wyle Electronics  
http://www.wyle.com  
W. E. Tel: 800.933.9953  
Englewood  
B. M.  
Tel: 800.255.1469  
Insight Electronics  
Tel: 317.575.3500  
Minneapolis  
I. E.  
Tel: 303.649.1800  
A. E.  
Tel: 612.346.3000  
Iowa  
W. E. Tel: 800.860.9953  
St. Louis Park  
Connecticut  
Cheshire  
W. E. Tel: 612.853.2280  
Cedar Rapids  
A. E.  
I. E.  
Tel: 612.525.9999  
Alabama  
Daphne  
I. E.  
Huntsville  
A. E.  
I. E.  
A. E.  
I. E.  
Tel: 203.271.5700  
Tel: 203.272.5843  
Tel: 319.393.0033  
Mississippi  
Tel: 334.626.6190  
Kansas  
W. E. Tel: 303.457.9953  
Kansas City  
Wallingford  
W. E. Tel: 800.605.9953  
A. E.  
Tel: 800.633.2918  
W. E. Tel: 256.830.1119  
Tel: 256.837.8700  
Tel: 256.830.1222  
Delaware  
A. E.  
Tel: 913.663.7900  
Missouri  
W. E. Tel: 800.964.9953  
North/South  
Lenexa  
I. E.  
W. E. Tel: 630.620.0969  
St. Louis  
A. E.  
Tel: 800.526.4812  
Tel: 800.638.5988  
Tel: 302.328.8968  
Tel: 913.492.0408  
Alaska  
A. E.  
I. E.  
Tel: 314.291.5350  
Tel: 314.872.2182  
A. E.  
Tel: 800.332.8638  
Kentucky  
W. E. Tel: 937.436.9953  
Central/Northern/ Western  
B. M.  
W. E. Tel: 856.439.9110  
Arkansas  
W. E. Tel: 972.235.9953  
Montana  
Florida  
Altamonte Springs  
A. E.  
Tel: 800.984.9503  
Tel: 800.767.0329  
Tel: 800.829.0146  
A. E.  
Tel: 800.526.1741  
W. E. Tel: 801.974.9953  
Arizona  
Phoenix  
B. M.  
I. E.  
Tel: 407.682.1199  
Tel: 407.834.6310  
Nebraska  
A. E.  
B. M.  
Tel: 480.736.7000  
Tel: 602.267.9551  
Louisiana  
W. E. Tel: 713.854.9953  
North/South  
A. E.  
Tel: 800.332.4375  
Boca Raton  
W. E. Tel: 303.457.9953  
I. E.  
Tel: 561.997.2540  
W. E. Tel: 800.528.4040  
Tempe  
Clearwater  
Nevada  
Las Vegas  
A. E.  
Tel: 800.231.0253  
Tel: 800.231.5575  
I. E.  
Tel: 727.524.8850  
I. E.  
Tel: 480.829.1800  
Fort Lauderdale  
Tucson  
A. E.  
A. E.  
Tel: 800.528.8471  
A. E.  
Tel: 954.484.5482  
Tel: 520.742.0515  
Maine  
A. E.  
W. E. Tel: 702.765.7117  
W. E. Tel: 800.568.9953  
Miami  
Tel: 800.272.9255  
California  
Agoura Hills  
New Hampshire  
W. E. Tel: 781.271.9953  
B. M.  
Tel: 305.477.6406  
A. E.  
Tel: 800.272.9255  
Orlando  
A. E.  
B. M.  
Irvine  
A. E.  
B. M.  
I. E.  
Tel: 818.865.0266  
Maryland  
Baltimore  
A. E.  
W. E. Tel: 800.863.9953  
Columbia  
B. M.  
I. E.  
W. E. Tel: 781.271.9953  
Tel: 407.657.3300  
W. E. Tel: 407.740.7450  
Tampa  
W. E. Tel: 800.395.9953  
St. Petersburg  
New Jersey  
North/South  
Tel: 949.789.4100  
Tel: 949.470.2900  
Tel: 949.727.3291  
Tel: 410.720.3400  
A. E.  
Tel: 201.515.1641  
Tel: 609.222.6400  
W. E. Tel: 800.626.9953  
Los Angeles  
Tel: 800.673.7461  
Tel: 410.381.3131  
A. E.  
Tel: 727.507.5000  
Mt. Laurel  
I. E.  
Tel: 609.222.9566  
A. E.  
Tel: 818.594.0404  
Georgia  
Atlanta  
A. E.  
Massachusetts  
Boston  
A. E.  
W. E. Tel: 800.444.9953  
Burlingtonr  
I. E.  
Marlborough  
B. M.  
Pine Brook  
W. E. Tel: 800.862.9953  
Parsippany  
W. E. Tel: 800.288.9953  
Sacramento  
Tel: 770.623.4400  
Tel: 770.980.4922  
Tel: 978.532.9808  
A. E.  
Tel: 916.632.4500  
B. M.  
I. E.  
Tel: 973.299.4425  
W. E. Tel: 800.627.9953  
San Diego  
W. E. Tel: 800.876.9953  
Duluth  
Wayne  
W. E. Tel: 973.237.9010  
Tel: 781.270.9400  
A. E.  
B. M.  
I. E.  
Tel: 858.385.7500  
Tel: 858.597.3010  
Tel: 800.677.6011  
I. E.  
Tel: 678.584.0812  
Tel: 800.851.2282  
Tel: 801.365.3800  
New Mexico  
W. E. Tel: 480.804.7000  
Albuquerque  
Tel: 508.480.9099  
Hawaii  
A. E.  
Woburn  
B. M.  
W. E. Tel: 800.829.9953  
San Jose  
Tel: 781.933.9010  
A. E.  
Tel: 505.293.5119  
Idaho  
A. E.  
A. E.  
B. M.  
I. E.  
Tel: 408.435.3500  
Tel: 408.436.0881  
Tel: 408.952.7000  
Michigan  
Brighton  
I. E.  
Detroit  
A. E.  
W. E. Tel: 801.974.9953  
Tel: 810.229.7710  
Santa Clara  
W. E. Tel: 800.866.9953  
Woodland Hills  
Illinois  
North/South  
Tel: 734.416.5800  
W. E. Tel: 888.318.9953  
A. E.  
Tel: 847.797.7300  
Tel: 314.291.5350  
A. E.  
Westlake Village  
I. E. Tel: 818.707.2101  
Tel: 818.594.0404  
Chicago  
B. M.  
Tel: 847.413.8530  
W. E. Tel: 800.853.9953  
Schaumburg  
I. E.  
Tel: 847.885.9700  
U.S. Distributors  
by State  
(Continued)  
New York  
South Carolina  
Wisconsin  
Hauppauge  
A. E.  
Tel: 919.872.0712  
Milwaukee  
I. E.  
Tel: 516.761.0960  
W. E. Tel: 919.469.1502  
A. E.  
Tel: 414.513.1500  
Long Island  
W. E. Tel: 800.867.9953  
Wauwatosa  
South Dakota  
A. E.  
Tel: 516.434.7400  
A. E.  
Tel: 800.829.0116  
W. E. Tel: 800.861.9953  
Rochester  
I. E.  
Tel: 414.258.5338  
W. E. Tel: 612.853.2280  
Wyoming  
A. E.  
I. E.  
Tel: 716.475.9130  
Tel: 716.242.7790  
Tennessee  
W. E. Tel: 256.830.1119  
East/West  
A. E.  
Tel: 800.332.9326  
W. E. Tel: 801.974.9953  
W. E. Tel: 800.319.9953  
Smithtown  
A. E.  
Tel: 800.241.8182  
Tel: 800.633.2918  
B. M.  
Tel: 800.543.2008  
Syracuse  
A. E.  
Tel: 315.449.4927  
Texas  
Austin  
A. E.  
B. M.  
I. E.  
North Carolina  
Raleigh  
A. E.  
I. E.  
Tel: 512.219.3700  
Tel: 512.258.0725  
Tel: 512.719.3090  
Tel: 919.859.9159  
Tel: 919.873.9922  
W. E. Tel: 800.365.9953  
Dallas  
W. E. Tel: 800.560.9953  
A. E.  
B. M.  
Tel: 214.553.4300  
Tel: 972.783.4191  
North Dakota  
A. E.  
Tel: 800.829.0116  
W. E. Tel: 800.955.9953  
El Paso  
W. E. Tel: 612.853.2280  
Ohio  
A. E.  
Tel: 800.526.9238  
Cleveland  
Houston  
A. E.  
A. E.  
Tel: 216.498.1100  
Tel: 713.781.6100  
Tel: 713.917.0663  
W. E. Tel: 800.888.9953  
Richardson  
W. E. Tel: 800.763.9953  
Dayton  
B. M.  
A. E.  
I. E.  
Tel: 614.888.3313  
Tel: 937.253.7501  
I. E.  
Tel: 972.783.0800  
W. E. Tel: 800.575.9953  
Strongsville  
Rio Grande Valley  
A. E.  
Tel: 210.412.2047  
B. M.  
Valley View  
Tel: 440.238.0404  
Stafford  
I. E.  
Tel: 281.277.8200  
I. E.  
Tel: 216.520.4333  
Utah  
Oklahoma  
Centerville  
W. E. Tel: 972.235.9953  
Tulsa  
B. M.  
Murray  
I. E.  
Tel: 801.295.3900  
A. E.  
I. E.  
Tel: 918.459.6000  
Tel: 918.665.4664  
Tel: 801.288.9001  
Salt Lake City  
A. E.  
Tel: 801.365.3800  
Oregon  
Beavertonr  
W. E. Tel: 800.477.9953  
B. M.  
I. E.  
Tel: 503.524.0787  
Tel: 503.644.3300  
Vermont  
A. E.  
Tel: 800.272.9255  
Portland  
A. E.  
W. E. Tel: 800.879.9953  
W. E. Tel: 716.334.5970  
Tel: 503.526.6200  
Virginia  
A. E.  
Tel: 800.638.5988  
Pennsylvania  
W. E. Tel: 301.604.8488  
Mercer  
I. E.  
Pittsburgh  
A. E.  
W. E. Tel: 440.248.9996  
Philadelphia  
A. E.  
B. M.  
Washington  
Kirkland  
Tel: 412.662.2707  
I. E.  
Tel: 425.820.8100  
Tel: 412.281.4150  
Seattle  
A. E.  
Tel: 425.882.7000  
W. E. Tel: 800.248.9953  
Tel: 800.526.4812  
Tel: 215.741.4080  
West Virginia  
W. E. Tel: 800.871.9953  
A. E.  
Tel: 800.638.5988  
Rhode Island  
A. E.  
800.272.9255  
W. E. Tel: 781.271.9953  
Direct Sales  
Representatives by State  
(Component and HAB)  
E. A.  
E. L.  
GRP  
I. S.  
ION  
R. A.  
Earle Associates  
Electrodyne - UT  
Group 2000  
Infinity Sales, Inc.  
ION Associates, Inc.  
Rathsburg Associ-  
ates, Inc.  
Texas  
Austin  
ION  
Arlington  
ION  
Tel: 512.794.9006  
Tel: 817.695.8000  
Tel: 281.376.2000  
Houston  
ION  
SGY  
Synergy Associates,  
Inc.  
Utah  
Salt Lake City  
Arizona  
Tempe  
E. A.  
E. L.  
Tel: 801.264.8050  
Wisconsin  
Muskego  
Tel: 480.921.3305  
R. A.  
Saukville  
R. A.  
Tel: 414.679.8250  
California  
Calabasas  
Tel: 414.268.1152  
I. S.  
Irvine  
I. S.  
Tel: 818.880.6480  
Tel: 714.833.0300  
San Diego  
E. A.  
Tel: 619.278.5441  
Illinois  
Elmhurst  
R. A.  
Tel: 630.516.8400  
Indiana  
Cicero  
R. A.  
Ligonier  
R. A.  
Tel: 317.984.8608  
Tel: 219.894.3184  
Tel: 317.838.0360  
Plainfield  
R. A.  
Massachusetts  
Burlington  
SGY  
Tel: 781.238.0870  
Michigan  
Byron Center  
R. A.  
Tel: 616.554.1460  
Good Rich  
R. A.  
Novi  
R. A.  
Tel: 810.636.6060  
Tel: 810.615.4000  
North Carolina  
Cary  
GRP  
Tel: 919.481.1530  
Ohio  
Columbus  
R. A.  
Tel: 614.457.2242  
Dayton  
R. A.  
Tel: 513.291.4001  
Independence  
R. A.  
Tel: 216.447.8825  
Pennsylvania  
Somerset  
R. A.  
Tel: 814.445.6976  
Sales Offices and Design  
Resource Centers  
LSI Logic Corporation  
Corporate Headquarters  
Tel: 408.433.8000  
Maryland  
Bethesda  
Tel: 301.897.5800  
Fax: 301.897.8389  
INTERNATIONAL  
Taiwan  
Taipei  
LSI Logic Asia, Inc.  
Taiwan Branch  
Tel: 886.2.2718.7828  
Fax: 886.2.2718.8869  
France  
Paris  
LSI Logic S.A.  
Immeuble Europa  
Tel: 33.1.34.63.13.13  
Fax: 33.1.34.63.13.19  
Fax: 408.433.8989  
NORTH AMERICA  
Massachusetts  
Waltham  
California  
Tel: 781.890.0180  
United Kingdom  
Bracknell  
LSI Logic Europe Ltd  
Tel: 44.1344.426544  
Fax: 44.1344.481039  
Costa Mesa - Mint Technology  
Tel: 949.752.6468  
Fax: 949.752.6868  
Fax: 781.890.6158  
Germany  
Munich  
LSI Logic GmbH  
Tel: 49.89.4.58.33.0  
Fax: 49.89.4.58.33.108  
Burlington - Mint Technology  
Tel: 781.685.3800  
Fax: 781.685.3801  
Irvine  
Tel: 949.809.4600  
Fax: 949.809.4444  
Minnesota  
Minneapolis  
Sales Offices with  
Stuttgart  
Design Resource Centers  
Pleasanton Design Center  
Tel: 925.730.8800  
Tel: 612.921.8300  
Tel: 49.711.13.96.90  
Fax: 49.711.86.61.428  
Fax: 612.921.8399  
Fax: 925.730.8700  
New Jersey  
Italy  
San Diego  
Red Bank  
Milano  
Tel: 858.467.6981  
Fax: 858.496.0548  
Tel: 732.933.2656  
Fax: 732.933.2643  
LSI Logic S.P.A.  
Tel: 39.039.687371  
Fax: 39.039.6057867  
Silicon Valley  
Cherry Hill - Mint Technology  
Tel: 609.489.5530  
Fax: 609.489.5531  
Tel: 408.433.8000  
Japan  
Tokyo  
Fax: 408.954.3353  
LSI Logic K.K.  
Tel: 81.3.5463.7821  
Fax: 81.3.5463.7820  
Wireless Design Center  
Tel: 858.350.5560  
New York  
Fairport  
Fax: 858.350.0171  
Tel: 716.218.0020  
Fax: 716.218.9010  
Osaka  
Colorado  
Boulder  
Tel: 81.6.947.5281  
North Carolina  
Raleigh  
Tel: 919.785.4520  
Fax: 919.783.8909  
Fax: 81.6.947.5287  
Tel: 303.447.3800  
Fax: 303.541.0641  
Korea  
Seoul  
Colorado Springs  
Tel: 719.533.7000  
Fax: 719.533.7020  
LSI Logic Corporation of  
Korea Ltd  
Tel: 82.2.528.3400  
Fax: 82.2.528.2250  
Oregon  
Beaverton  
Tel: 503.645.0589  
Fax: 503.645.6612  
Fort Collins  
Tel: 970.223.5100  
Fax: 970.206.5549  
The Netherlands  
Eindhoven  
Texas  
Austin  
Tel: 512.388.7294  
Fax: 512.388.4171  
LSI Logic Europe Ltd  
Tel: 31.40.265.3580  
Fax: 31.40.296.2109  
Florida  
Boca Raton  
Tel: 561.989.3236  
Fax: 561.989.3237  
Plano  
Singapore  
Tel: 972.244.5000  
Singapore  
Georgia  
Alpharetta  
Tel: 770.753.6146  
Fax: 770.753.6147  
Fax: 972.244.5001  
LSI Logic Pte Ltd  
Tel: 65.334.9061  
Fax: 65.334.4749  
Houston  
Tel: 281.379.7800  
Fax: 281.379.7818  
Tel: 65.835.5040  
Fax: 65.732.5047  
Illinois  
Oakbrook Terrace  
Tel: 630.954.2234  
Fax: 630.954.2235  
Canada  
Ontario  
Ottawa  
Sweden  
Stockholm  
Tel: 613.592.1263  
LSI Logic AB  
Kentucky  
Fax: 613.592.3253  
Tel: 46.8.444.15.00  
Bowling Green  
Tel: 270.793.0010  
Fax: 270.793.0040  
Fax: 46.8.750.66.47  
International Distributors  
Australia  
Japan  
New South Wales  
Reptechnic Pty Ltd  
Tel: 612.9953.9844  
Fax: 612.9953.9683  
Tokyo  
Global Electronics  
Corporation  
Tel: 81.3.3260.1411  
Fax: 81.3.3260.7100  
Technical Center  
Tel: 81.471.43.8200  
Belgium  
Acal nv/sa  
Tel: 32.2.7205983  
Fax: 32.2.7251014  
Yokohama-City  
Macnica Corporation  
Tel: 81.45.939.6140  
Fax: 81.45.939.6141  
China  
Beijing  
LSI Logic International  
Services Inc.  
Tel: 86.10.6804.2534  
Fax: 86.10.6804.2521  
The Netherlands  
Eindhoven  
Acal Nederland b.v.  
Tel: 31.40.2.502602  
Fax: 31.40.2.510255  
France  
Rungis Cedex  
Azzurri Technology France  
Tel: 33.1.41806310  
Fax: 33.1.41730340  
Switzerland  
Brugg  
LSI Logic Sulzer AG  
Tel: 41.32.3743232  
Fax: 41.32.3743233  
Germany  
Haar  
EBV Elektronik  
Tel: 49.89.4600980  
Fax: 49.89.46009840  
Taiwan  
Taipei  
Avnet-Mercuries  
Corporation, Ltd  
Tel: 886.2.2516.7303  
Fax: 886.2.2505.7391  
Munich  
Avnet Emg GmbH  
Tel: 49.89.45110102  
Fax: 49.89.42.27.75  
Lumax International  
Corporation, Ltd  
Wuennenberg-Haaren  
Peacock AG  
Tel: 886.2.2788.3656  
Fax: 886.2.2788.3568  
Tel: 49.2957.79.1692  
Fax: 49.2957.79.9341  
Prospect Technology  
Corporation, Ltd  
Hong Kong  
Hong Kong  
Tel: 886.2.2721.9533  
Fax: 886.2.2773.3756  
AVT Industrial Ltd  
Tel: 852.2428.0008  
Fax: 852.2401.2105  
Serial Semiconductor  
Corporation, Ltd  
Tel: 886.2.2579.5858  
Fax: 886.2.2570.3123  
EastEle  
Tel: 852.2798.8860  
Fax: 852.2305.0640  
United Kingdom  
Maidenhead  
India  
Bangalore  
Spike Technologies India  
Private Ltd  
Azzurri Technology Ltd  
Tel: 44.1628.826826  
Fax: 44.1628.829730  
Tel: 91.80.664.5530  
Swindon  
Fax: 91.80.664.9748  
EBV Elektronik  
Tel: 44.1793.849933  
Fax: 44.1793.859555  
Israel  
Tel Aviv  
Eastronics Ltd  
Tel: 972.3.6458777  
Fax: 972.3.6458666  
Sales Offices with  
Design Resource Centers  

相关型号:

SYM22902

SYM22902 PCI to Ultra2 SCSI Dual Channel low profile PCI host adapter user's guide v1.0
ETC

SYM430-408B

Analog IC
ETC

SYM450-471B

Analog IC
ETC

SYM5270

Dual LED Lamp
AUK

SYM53C040(PBGA)

Microprocessor
ETC

SYM53C040(PQFP)

Microprocessor
ETC

SYM53C1010

Interface IC
ETC

SYM53C141

Interface IC
ETC

SYM53C770

SCSI Bus Interface/Controller
ETC

SYM53C876E(PBGA)

SCSI Bus Interface/Controller
ETC

SYM53C876E(PQFP)

SCSI Bus Interface/Controller
ETC

SYM53C885

Telecommunication IC
ETC