TDC-GP2 to TDC-GP21 Migration and  
Compatibility Guideline  
This paper is an add-on to the TDC-GP21 datasheet. It describes the functional and configuration  
differences between TDC-GP2 and TDC-GP21.  
Hardware and Software Compatibility  
The TDC-GP21 offers an extended architecture that, within some very small restrictions, is fully  
compatible to existing TDC- GP2 designs. According to its new features the GP21 configuration  
register architecture is extended compared to TDC-GP2. However, the device supports 100%  
downwards compatibility so there is no need for any hardware and software adaption when  
switching your design from GP2 to GP21.  
I/O supply voltage  
The GP21 I/O supply voltage (Vio) is limited to max. 3.6 V, compared 5.5 V with TDC-GP2.  
Chip marking  
Basically, the GP21 chip marking is identical except for one difference. Compared to TDC-GP2 the  
acam label on GP21 package might be rotated in some device charges. According to that we  
strongly recommend to check the position of the orientation indicator (and not the acam label)  
to ensure a correct PCB assembly of the device.  
Fire out configuration  
GP2 configurations where Fire1 and Fire2 are switched in parallel are not supported by the GP21.  
This leads to a misbehaving of your system as the GP21 fire pulse generator will not generate any  
output signals. In this case a small software modification is necessary that changes the settings of  
CONF_FIRE parameter in configuration register 5.  
To get access to the device’s extended functionality some hardware- and software modifications are  
necessary.  
32 kHz Oscillator  
Basically, the TDC-GP21 offers full clock signal compatibility to TDC-GP2. With GP21 the internal 32  
kHz clock driver has an additional low power option. This reduces current consumption of the 32 kHz  
quartz to typ. 600 nA (compared to typ. 4.5 µA in GP2). So the stand by current of the GP21 with  
active 32 kHz clock is reduced to 1 µA.  
Table 1: Current consumption of 32 kHz clock source in GP2 /GP21  
TDC-GP2  
Min. Typ.  
4.5  
TDC-GP21  
Min. Typ.  
0.6  
Symbol  
I32  
Description  
Current 32 kHz  
Max.  
Max. Unit  
µA  
Also the TDC-GP21 offers enhanced clock options for clock distribution via FIRE_IN pin. They are  
available via register 1 configuration. According to that, FIRE_IN can be defined as a 32.768 Hz or  
4.096 Hz clock signal output, e. g. as a low-current clock signal source for an external microprocessor.  
Table 2 provides the details:  
acam-messelectronic gmbh  
Seite 1  
KW 02.02.2011  
Table 2: Parameters for enhanced clock options of TDC-GP21  
Parameter  
SEL_TSTO2  
Terminal  
Reg1[11:13]  
Description  
Value  
Additional functionality  
of Fire_In pin for clock  
signal output  
Low power option for 32 1 = enabled (recommended)  
kHz clock 0 = disabled  
7 = 4 kHz out (32 kHz / 8)  
SEL_TSTO1  
Curr32  
Reg1[10:8]  
Reg1[15]  
7 = 32 kHz out  
Time measurement unit  
The base resolution of the GP21 is typ. 90 ps. In measure mode 2 it can be improved by setting  
Double resolution (typ. 45 ps) and Quad resolution (typ. 22 ps) mode. For GP2 compatibility the GP21  
by default operates in standard mode (GP2 mode, 90 ps resolution). Configuring higher resolution  
requires write access to configuration register 6. This register is part of the extended register  
architecture of the TDC-GP21. Setting bit 12 or 13 activates double or quad resolution mode  
Table 3: GP21 Double and Quad resolution mode  
Parameter  
QUAD_RES  
Terminal  
Reg6[13]  
Description  
Improves resolution from 90  
ps to 22 ps in measure mode 2 1 = 0n  
Value  
0 = off (GP2 compatibility)  
Improves resolution from 90  
ps to 45 ps in measure mode 1  
and 2  
0 = off (GP2 compatibility)  
1 = 0n  
DOUBLE_RES  
Reg6[12]  
All details about the TDC-GP21 register architecture are available in chapter 3 of the datasheet.  
Fire Pulse generator  
With GP21 the maximum number of send pulses has been increased to 127. A detailed description of  
the fire pulse generator is available in TDC-GP21 datasheet section 5.2.1. Information about the  
correct configuration is described in section 5.2.2.  
Table 4: New parameters for GP21 fire pulse generator  
Parameter  
Terminal  
Description  
Value  
Reg0[31:28]  
Reg6[10:8]  
0 = off  
127 = 127 pules  
ANZ_FIRE  
Sets number of pulses  
Bit 23 = 1: Fire both  
Bit 22 = 1: disable Fire_Up  
Bit 21 = 1: disable Fire_Down  
0 = GP2 behaviour  
1 = use Fire as TDC start  
0 = High-Z (GP2-Mode)  
1 = Low (mandatory to use  
analog input section)  
Output configuration for pulse  
generator  
CONF_FIRE  
Reg5[31:29]  
Reg1[14]  
SEL_START_FIRE  
FIRE_DEFAULT  
Uses fire pulse signal as start  
Specifies default level of  
inactive fire buffer  
Reg6[14]  
Analog input section  
The TDC-GP21 integrates a complete analog section. It can be used alternatively to the pure digital  
input. This significantly simplifies the design of ultrasonic flow and heat meters, which is one of the  
main application areas of the TDC-GP21.  
acam-messelectronic gmbh  
Seite 2  
KW 02.02.2011  
The signals are coupled to the TDC-GP2 analog inputs by means of a high pass filter. This is necessary  
as the comparator cannot handle GND as threshold. Thus, the input signal level of the non-inverted  
comparator input is switched to 1/3 Vcc. According to that the comparators threshold is also 1/3 Vcc.  
Figure 1 shows the corresponding oscilloscope trace.  
Figure 1: Signal curve on non-inverted comparator input. (measured at TP1)  
Received pulse  
sequence  
LoadC charging to 1/3Vcc  
(comparator threshold)  
Send pulses  
The GP21 integrates complete control for a measurement cycle. Figure 2 shows an oscilloscope trace  
of a measurement cycle with a 1 MHz signal burst (20 pulses).  
Figure 2: Oscillogram of a complete measurement cycle (measured at TP2 and TP3)  
Send pulses  
Received pulse  
sequence  
acam-messelectronic gmbh  
Seite 3  
KW 02.02.2011  
According to the received pulse sequence the integrated comparator generates a digital output  
signal that is internally feed into stop1 input. With SEL_TST1 = 6 (configuration register 6) the  
comparator output signal is available on FIRE_IN pin,(e. g. for hardware diagnosis) as shown below.  
Figure 3: Received pulse sequence and corresponding comparator output signal  
Comparator  
output signal  
Received pulse  
packet  
Table 6: Configuration parameters that are relevant for the GP21 analog section  
Parameter Terminal  
EN_Analog Reg6[31]  
Description  
Value  
0 = Stop1 and Stop2 are digital  
inputs (GP2 compatibility)  
1 = activates analog section  
Activates analog part for ultrasonic  
flow measurements  
0 = 90 µs  
1 = 120 µs  
2 = 150 µs  
3 = 300 µs  
0 = 1  
1 = 1.5  
2 = 2  
3 = 2.5  
Sets charge time of capacitor LoadC  
when the integrated analog section  
is used  
TW2  
Reg6[23:22]  
Selects timer for triggering the  
second Time-of-Flight measurement  
in multiples of 50/60 Hz  
CYCLE_TOF Reg6[17:16]  
Forces GP21 to execute a complete  
up and down flow measurement  
cycle and two temperature  
measurement in series. The time  
interval between two measurements  
is based on 50 / 60 Hz  
0 = 50 Hz base (20 ms)  
1 = 60 Hz base (16.67 ms)  
HZ60  
Reg6[15]  
A detailed description of the analog section is available in section 4.3 of the TDC-GP21 datasheet.  
Temperature measuring unit  
The GP21 temperature measurement unit has the comparator already integrated. Due to GP2  
compatibility it also works with an external Schmitt Trigger. Here we recommend the 74AHC14 to get  
acam-messelectronic gmbh  
Seite 4  
KW 02.02.2011  
best results. The functional details are described in section 4.4 of the datasheet. The following table  
provides an overview of the relevant configuration parameters.  
Additionally, the GP21 provides the opportunity to execute two cyclic temperature measurements  
that are synchronized with 50/60 Hz, in order to reduce 50/60 Hz noise. Here, the TDC-GP21  
automatically starts the second temperature measurement after the selected time (Cycle_TEMP).  
When using this option, it important that the first measurement result has to be read out before the  
second temperature measurement is started by the GP21. Otherwise it will be overwritten after the  
second temperature measurement has been finished.  
Table 8: Additional configuration Parameters for GP21 temperature measurement unit  
Parameter  
Terminal  
Description  
Value  
Inverts the SenseT input  
signal. Has to be set when  
internal Schmitt-trigger is uses  
trigger  
0 = external Schmitt Trigger  
(GP2 compatibility)  
1 = internal Schmitt-trigger  
NEG_STOP_TEMP Reg6[30]  
Selects timer for triggering the 0 = 1  
second temperature  
measurement in multiples of  
50/60 Hz  
1 = 1.5  
2 = 2  
3 = 2.5  
Cycle_TEMP  
Reg6[19:18]  
Option for measuring the  
temperature ports in the  
opposite order  
0 = PT1>PT2>PT3>PT4  
1 = PT4>PT3>PT2>PT1  
TEMP_PORT_DIR Reg6[11]  
Sets base frequency for delay  
between up and down  
measurement  
0 = 50 Hz base  
1 = 60 Hz base  
HZ60  
Reg6[15]  
Configuration Register Architecture  
The GP21 includes 7 configuration registers, each with 32-bit width (compared to 6 x 24 bit in GP2).  
The register organization is fully downwards compatible to GP2. To get access to the extended  
configuration space in order to use the enhanced GP2 functionality, the SPI communication has to be  
expanded by one additional byte of configuration data.  
TDC-GP2:  
TDC-GP21:  
Opcode + Address + 3 Bytes configuration data  
Opcode + Address + 4 Bytes configuration data  
The complete register set is described in section 3 of the datasheet. Details about the SPI  
communication can be found in section 3.4.  
Internal EEPROM  
The TDC-GP21 integrates a 7x32 bit EEPROM that can be used to store the configuration data  
together with a system ID or version number. For details please refer to section 3.3 of the datasheet.  
Interrupt sources  
The GP21 interrupt behavior is expanded by an additional interrupt source, that especially refers to  
EEPROM access. It has to be enabled by activating bit 21 in configuration registers 6. Then the end of  
an EEPROM action is indicated by an Interrupt.  
Table 9: EEPRPOM action as interrupt source  
acam-messelectronic gmbh  
Seite 5  
KW 02.02.2011  
Parameter  
EN_INT[3]  
Terminal  
Reg6[21]  
Description  
Value  
Highest bit to enable additional  
EEPROM action as additional  
interrupt source. See also register 2  
for lower 3 bits (GP2 compatible  
interrupt sources)  
0 = disable EEPROM action  
as interrupt (GP2  
compatibility)  
1 = end of EEPROM action  
is indicates by an interrupt  
Basic Reference Design  
Test measurements were made with a GP21 hardware connected to a Weihai Ploumeter spoolspiece  
with 1 MHz transducers. TP1 to TP3 indicate the test points where the oscilloscope has been  
connected.  
Circuit Schematic, Testpoints and Register Configuration  
Figure 4: circuit schematic  
TP2  
TP1  
TP3  
The following register configuration has been used for the test measurement.  
Table 10: Content of TDC-GP21 configuration registers  
Configuration Register Address  
Register Content  
0xA30B6800  
0x21044000  
0x2024B800  
0x102A3000  
0x202AF855  
0x40000000  
0cC0006000  
Register 0  
Register 1  
Register 2  
Register 3  
Register 4  
Register 5  
Register 6  
0
1
2
3
4
5
6
Related Documentation  
acam-messelectronic gmbh -, TDC-GP21 datasheet, available from www.acam.de  
acam-messelectronic gmbh  
Seite 6  
KW 02.02.2011  

相关型号:

TDC0071DP

TDC0071DP
STMICROELECTR

TDC0082DP

TDC0082DP
STMICROELECTR

TDC0084DP

TDC0084DP
STMICROELECTR

TDC0353

TDC0353
STMICROELECTR

TDC10

Barrier Strip Terminal Block, 30A, 1 Deck(s)
ADAM-TECH

TDC10-1-R

Electric Fuse, Fast Blow, 1A, 350VAC, 10A (IR), Inline/holder, ROHS COMPLIANT
COOPER

TDC10-1-R

(TDC10) fast-acting (TDC11) time delay glass tube fuses
EATON

TDC10-1.5-R

(TDC10) fast-acting (TDC11) time delay glass tube fuses
EATON

TDC10-1.5A

TDC Series, Glass Tube
COOPER

TDC10-10-R

(TDC10) fast-acting (TDC11) time delay glass tube fuses
EATON

TDC10-100-R

(TDC10) fast-acting (TDC11) time delay glass tube fuses
EATON

TDC10-100MA

TDC Series, Glass Tube
COOPER