TXD20008AEFLLNH [ETC]
Analog IC ; 模拟IC\n型号: | TXD20008AEFLLNH |
厂家: | ETC |
描述: | Analog IC
|
文件: | 总4页 (文件大小:221K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Product Data Sheet
2000 WATT
AC/DC POWER SUPPLY
TXD2000
DESCRIPTION
TheTXD2000 Series is a flexible, modular, 2000 Watt
design offering two high current outputs in a 5 x 8 x 12
package. Output voltages from 2.5 VDC through 48
VDC are standard.With Power Factor Correction, EMI
compliance to FCC and CISPR22, CE Mark and
immunity to EN61000-4, theTXD2000 Series is ready
for global deployment. Standard features include
Remote Sense Compensation, Output Voltage
Adjustment, Active Current Sharing, Remote Inhibit,
Power Fail Warning, DC OK Signal and Thermal
Shutdown. An optional ORing diode is offered on
models with an output voltage of 12 VDC or above.
FEATURES
!Wide Range Input of 90-264VAC,1000Watts,
High Range Input of 180-264VAC, 2000Watts,
! Harmonic Correction to EN61000-3-2
! Active Current Sharing
! No Load Operation
! Optional ORing Diode
! 70-80% Efficiencies
! FCC / CISPR 22 Class A EMI Filtering
! Self-Cooled 5”x 8”x 12” Chassis
! EN61000-4 Immunity
AGENCY APPROVALS
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive,Tucson, Arizona 85706
Phone: 800.547.2537 Fax: 520.770.9369
Power Electronics Division, Europe
C&DTechnologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel:+353.61.474.133
Fax:+353.61.474.141
Page 1
TXD2000 2/2000 REV A
Powered by ICminer.com Electronic-Library Service CopyRight 2003
Input Specifications
Parameters
Operating Range
1000W
Conditions
Min
Typ
Max
Units
47-63Hz
90
264
264
80
VAC
VAC
Apk
Apk
%
2000W
47-63Hz
180
Inrush Current
120VAC, 250C, cold start
240VAC, 250C, cold start
Nominal line, full load
Full load
160
80
Efficiency
70
20
75
Holdup
msec
Power Factor (1)
Full load
0.99
Notes: (1) Harmonic currents meet EN61000-3-2
Output Voltage Modules and Maximum Rated Load
Output
Voltage Code
OutputVoltage
Output Current
Output Power
Voltage
(Maximum Continuous) (Maximum Continuous)
A
B
C
D
E
F
G
H
J
5.0
12.0
15.0
18.0
24.0
28.0
36.0
48.0
20.0
3.3
200A
83A
67A
55A
42A
36A
28A
21A
40A
182A
200A
1000W
1000W
1000W
1000W
1000W
1000W
1000W
1000W
800W
K
L
600W
2.5
500W
Output Specifications
Parameter
Output Power
90-264VAC
180-264VAC
Conditions
All environmental and line conditions
Min
Typ
+5
Max
Units
1000
2000
Watts
Watts
%
Limited by output module selection
Voltage Adjustment Range Relative to nominal output voltage
Output Regulation
Minimum Load
PARD
Line, load or cross
+0.2
%
0
Amps
Measured at output terminals, 20MHz
00 to 500C
50 mv or 1% pk-pk
%/0C
Temperature Coefficient
+0.2
Environmental Specifications
Parameter
Conditions
Min
Typ
Max
Units
Ambient Temperature
(Operating)
Output de-rated linearly to 50% of
rated capacity between 500C and 700C
0
+70
+85
0C
0C
Ambient Temperature
Altitude (Operating)
Altitude (Non-operating)
Shock
Non-operating
-50
-200
-200
+10,000 Feet
+50,000 Feet
Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test
Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test
The TXD2000 is provided with internal cooling fans.
Vibration
Cooling
Page 2
Powered by ICminer.com Electronic-Library Service CopyRight 2003
TXD2000 2/2000 REV A
Product Features
Features
Characteristic
Remote Sense
Active Current Sharing
ORing Diode
500mV compensation
Single Wire; 5% current share if outputs are over 25% of rated load
Optional (not available on modules below 12V)
125% of nominal (+7.5%)
OVP
Thermal Shutdown
DC OK Signal
Power Fail Warning
Remote Inhibit
Automatic Restart
Logic “1” when output is within +3% of nominal
Transition to Logic “0” at least 5msec before loss of output regulation
Logic “0” applied will inhibit output (referenced to –Sense terminal)
Product Compliances
Approval
UL and cUL
VDE
Characteristic
UL1950, 3rd Edition (1)
EN60950
FCC
Class A requirements for conducted emissions
Class A requirements for conducted emissions
Electrostatic Discharge, Level 4
Electrical Fast Transients, Level 3
Input Surge Immunity, Level 3
Harmonic Currents, Class A
Low Voltage Directive
CISPR 22
EN61000-4-2
EN61000-4-4
EN61000-4-5
EN61000-3-2
CE Mark
Notes: (1) UL1950, 3rd Edition incorporates the requirements of CSA 950.
Ordering Information
Model Designation
TXD2000
F
L
L
H
BASE MODEL
Chassis: “8” = 5” x 8” x 12”; “M” = modified
Output Voltage Module A: (see chart below)
Output Voltage Module B: (see chart below)
Standard Fan:“F”:
Remote Inhibit - TTL Logic Level “0” turns the power supply OFF:
Power Fail Warning - TTL Logic Level “0” indicates AC is LOST:
ORing Diode - “D” indicates an ORing Diode is installed in each module; “N” = None:
DC OK - TTL Logic Level “1” indicates DC is OK:
OUTPUT VOLTAGES
A = 5V
G = 36V
H = 48V
J = 20V
K = 3.3V
L = 2.5V
B = 12V
C = 15V
D = 18V
E = 24V
F = 28V
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice.
No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIESdoes not authorize or warrant any C&D TECHNOLOGIES
product for use in life support devices/systems or in aircraft control applications.
Page 3
TXD2000 2/2000 REV A
Powered by ICminer.com Electronic-Library Service CopyRight 2003
Page 4
TXD2000 2/2000 REV A
Powered by ICminer.com Electronic-Library Service CopyRight 2003