UDM35HSXSYR4LTX [ETC]

Digital Panel Meters Modular Indicator and Controller; 数字面板表模块指示灯和控制器
UDM35HSXSYR4LTX
型号: UDM35HSXSYR4LTX
厂家: ETC    ETC
描述:

Digital Panel Meters Modular Indicator and Controller
数字面板表模块指示灯和控制器

控制器
文件: 总11页 (文件大小:667K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Digital Panel Meters  
Modular Indicator and Controller  
Type UDM35  
Multi-input modular instrument 3 1/2 dgt LED  
• 0.1% RDG basic accuracy  
• TRMS AC current and voltage measurements  
• AC/DC current measurements: selectable full scales  
(200µA to 5A)  
• AC/DC voltage measurements: selectable full scales  
(200mV to 500V)  
• °C or °F temperature measurements  
(Pt100-250-500-1000, Ni100, TC J-K-S-T-E)  
• Resistance measurements: selectable full scales  
(20to 20k)  
• Up to 4 independent alarm set-points (optional)  
• 20mA/10VDC analog output (optional)  
• Serial port RS485 or RS232 (optional)  
• MODBUS, JBUS communication protocol  
• Front protection degree: IP67, NEMA4x  
Product Description  
How to order  
UDM35 XXX XX XX X XX  
µp-based  
digital  
panel  
means of optional UdmSoft  
software. UDM35 includes  
storage min-max functions  
and double level protection  
Model  
Slot A  
Slot B  
Slot C  
Slot D  
Options  
meter, 3 1/2 dgt LED indica-  
tor, for current, voltage, tem-  
perature and resistance  
measurements. Measuring  
ranges and functions easily  
programmable from the key-  
pad or from the PC by  
password.  
Housing  
for  
panel mounting with front  
protection degree: IP67,  
NEMA4x.  
How to order  
UdmSoft-kit  
UdmSoft-kit: software plus “UCOM1” communication cable for  
programming UDM35 by means of PC.  
Type Selection  
Slot A (measuring inputs)  
Slot B (communication)  
Slot C (communication and alarm)  
Slot D (power supply)  
LSX: signal inputs:  
0.2-2-20mA DC/AC;  
0.2-2-20V DC/AC  
XX:  
SX:  
SY:  
None  
Serial port RS485  
Serial port RS232  
XX:  
R1:  
None  
H:  
L:  
90 to 260V AC/DC  
18 to 60V AC/DC  
single relay output,  
(AC1-8AAC, 250VAC)  
Dual relay output,  
(AC1-8AAC, 250VAC)  
Dual relay output (AC1-  
8AAC, 250VAC) + dual  
open collector output  
(NPN, 100mA)  
LSE/  
AV (*): Single analogue output,  
0 to 20mA DC and  
0 to 10V DC  
R2:  
R4:  
LSF: signal inputs + AUX:  
0.2-2-20mA DC/AC;  
0.2-2-20V DC/AC  
Options  
HSX: signal inputs:  
0.2-2-5A DC/AC;  
(*):  
The two analogue  
outputs cannot be  
used at the same  
time. It is possible to  
plug in only one  
module by instru-  
ment.  
20-200-500V DC/AC  
TRX: signal inputs: TC tem-  
perature probes (J-K-S-  
T-E, Pt100-250-500-  
1000) and resistance  
(0.02-0.2-2-20k)  
R5:  
4 relay outputs  
(AC1-5AAC, 250VAC)  
XX:  
TX:  
None  
Tropicalization  
AV(*): Single analogue output,  
0 to 20mA DC and  
0 to 10V DC  
Input Specifications  
Analogue inputs  
BQ LSX module  
BQ LSE/BQ LSF module  
BQ HSX module  
BQ TRX module  
BQ TRX module  
Channels and variable  
Contact reading signal  
BQ xxx: <0.1mA, <3,5V DC  
BQ LSE/BQ LSF: <2.5mA,  
<14V DC  
1, mA and V DC/AC  
1, mA and V DC/AC + AUX  
1, A and V DC/AC  
1, temperature  
Close contact resistance  
Open contact resistance  
Insulation  
Max 1kΩ  
Min 500kΩ  
Non-insulated  
1, resistance  
Accuracy (display, RS485)  
See table “Measuring  
accuracy”, temperature drifts  
and minimum-maximum  
indications”  
Digital inputs  
Number of inputs  
Use  
Incl. in the measuring module  
1 (voltage-free)  
key-pad lock  
Display hold  
Reset of latch alarms  
Specifications are subject to change without notice UDM35DS 040706  
1
UDM35  
Input specifications (cont.)  
Additional errors  
waves.  
Direct  
Humidity  
0.3% RDG, 60% to 90% R.H.  
0.4% RDG, 62 to 440 Hz  
0.5% RDG @ 400 A/m  
Coupling type  
Crest factor  
Input frequency  
Magnetic field  
3; APmax=1.7In; VPmax=1.7Un  
Input impedance  
See table “input  
impedances and overloads”  
Temperature drift  
See table “Measurement  
accuracy, temperature drifts,  
and max/min indications”  
Frequency  
Overload  
40 to 440 Hz  
See table “input  
impedances and overloads”  
Sampling rate  
Display refresh time  
Display  
500 samples/s @ 50 Hz  
200 msec @ 50Hz  
Compensation  
Only temperature  
measurement module.  
3 1/2 DGT,  
7 segments  
height 14.2 mm  
Colour: red  
RTD  
- For Pt 100-250-500-1000,  
3-wire connection: up to 10Ω  
- For resistance measur. with  
20range: up to max 0.1Ω  
- For resistance measurements  
with 200range: up to max 10Ω  
Internal cold junction, within  
the temperature range  
Max and min indication  
Measurements  
See table “Measurement  
accuracy, temperature drifts  
and max min indications”  
TC  
Current, voltage, tempera-  
ture and resistance. For the  
current and voltage mea-  
surements: TRMS measure-  
ment of distorted sine  
from 0 to +50ꢀC.  
Automatic compensation  
or manual from 0 to 50ꢀC.  
Measurement accuracy, temperature drifts, max and min indications  
All accuracies and min/max indications are referred to an ambient temperature range of 25ꢀC 5ꢀC, relevant humidity 60% and scale ratio  
(electrical/displayed scale) equal to 1. The conversion into ꢀF is obtained acting on the electrical/displayed scale ratio.  
Module  
Inputs  
Type  
Accuracy  
Temp. drift  
Min. indicat. (<)  
Max. indicat. (<)  
DC: (0.1%RDG+3DGT)  
0% to 25% FS;  
-200µA to +200µA  
-2mA to +2mA  
-20mA to +20mA  
-200mV to +200mV  
-2V to +2V  
- 199.9  
- 1.999  
- 19.99  
- 199.9  
- 1.999  
- 19.99  
+ 199.9  
+ 1.999  
+ 19.99  
+ 199.9  
+ 1.999  
+ 19.99  
(0.1%RDG+2DGT)  
25% to 110% FS.  
TRMS (45 to 65Hz)*:  
(0.3%RDG+3DGT)  
0% to 25% FS;  
BQ LSX/  
BQ LSE/  
BQ LSF  
DC/AC  
150 ppm/ꢀC  
-20V to +20V  
(0.3%RDG+2DGT)  
25% to 110% FS.  
DC: (0.1%RDG+3DGT)  
0% to 25% FS;  
-200mA to +200mA  
-2A to +2A  
- 199.9  
- 1.999  
- 5.00  
- 19.99  
- 199.9  
- 500  
+ 199.9  
+ 1.999  
+ 5.00  
+ 19.99  
+ 199.9  
+ 500  
(0.1%RDG+2DGT)  
25% to 110% FS.  
DC/AC TRMS (45 to 65Hz)*:  
(0.3%RDG+3DGT)  
0% to 25% FS;  
-5A to +5A  
BQ HSX  
150 ppm/ꢀC  
-20V to +20V  
-200V to +200V  
-500V to +500V  
(0.3%RDG+2DGT)  
25% to 110% FS.  
-50ꢀC to +760ꢀC  
-58 ꢀF to +1400 ꢀF  
-200ꢀC to +1260ꢀC  
-328 ꢀF to +2000ꢀF  
-200ꢀC to +1000ꢀC  
-328ꢀF to +1832ꢀF  
-50ꢀC to +1750ꢀC  
-58ꢀF to +2000ꢀF  
-200ꢀC to +400ꢀC  
-328ꢀF to +752ꢀF  
J
J
(0.2%RDG+1DGT)  
(0.2%RDG+2DGT)  
(0.2%RDG+2DGT)  
(0.2%RDG+4DGT)  
(0.2%RDG+2DGT)  
(0.2%RDG+4DGT)  
(0.2%RDG+2DGT)  
(0.2%RDG+4DGT)  
(0.2%RDG+2DGT)  
(0.2%RDG+4DGT)  
- 50ꢀC  
- 58ꢀF  
+ 760ꢀC  
+ 1400ꢀF  
+ 1260ꢀC  
+ 1999ꢀF  
+ 1000ꢀC  
+ 1832ꢀF  
+ 1750ꢀC  
+ 1999ꢀF  
+ 400ꢀC  
+ 752ꢀF  
K
K
E
E
S
S
T
T
- 200ꢀC  
- 328ꢀF  
- 200ꢀC  
- 328ꢀF  
- 50ꢀC  
- 58ꢀF  
BQ TRX  
thermo-  
couple  
150 ppm/ꢀC  
- 200ꢀC  
- 328ꢀF  
*
<45Hz >65Hz= (0.5%RDG+3DGT) 0% to 25% FS; (0.5%RDG+2DGT) 25% to 110% FS.  
(<) The min. indication for TRMS measurement (AC or DC) is 0; it is possible to modify the decimal point position.  
2
Specifications are subject to change without notice UDM35DS 040706  
UDM35  
Measurement accuracy, temp. drifts, min max indications (cont.)  
All accuracies and min/max indications refer to an ambient temperature range of 25ꢀC 5ꢀC, relevant humidity 60% and scale ratio (elec-  
trical scale / displayed scale) equal to 1. The conversion into ꢀF is obtained acting on the electrical scale / displayed scale .  
Module  
Inputs  
Type  
Accuracy  
Temp. Drift  
Min. Indication  
Max. Indication  
-200ꢀC to +850ꢀC Pt100  
-328ꢀF to +1562ꢀF Pt100  
-200.0ꢀC to +200.0ꢀC Pt100  
(0.2%RDG + 2DGT)  
(0.2%RDG + 4DGT)  
(0.5%RDG + 5DGT)  
(0.5%RDG + 5DGT)  
(0.5%RDG + 5DGT)  
(0.5%RDG + 5DGT)  
(0.5%RDG + 5DGT)  
(0.5%RDG + 5DGT)  
(0.5%RDG + 5DGT)  
(0.5%RDG + 5DGT)  
(0.5%RDG + 1DGT)  
(0.5%RDG + 2DGT)  
- 200  
- 328  
+ 850  
+ 1562  
+199.9  
+199.9  
+199.9  
+199.9  
+199.9  
+199.9  
+199.9  
+199.9  
+ 180  
-199.9  
-199.9  
-199.9  
-199.9  
-199.9  
-199.9  
-199.9  
-199.9  
- 60  
-328ꢀF to +392ꢀF  
-200.0ꢀC to +200.0ꢀC Pt250  
-328ꢀF to +392ꢀF Pt250  
-200.0ꢀC to +200.0ꢀC Pt500  
-328ꢀF to+392ꢀF Pt500  
Pt100  
BQ TRX  
Ther-  
moresis-  
tance  
150 ppm/ꢀC  
-200.0ꢀC to +200.0ꢀC Pt1000  
-328ꢀF to +392ꢀF Pt1000  
-60ꢀC to +180ꢀC  
-76ꢀF to +356ꢀF  
Ni100  
Ni100  
- 76  
+ 356  
0 to 20Ω  
0 to 200Ω  
0 to 2000Ω  
0 to 20.00kΩ  
(0.2%RDG+2DGT)  
25% to 110% FS  
(0.2%RDG+3DGT)  
0% to 25% FS  
0
0
0
0
19.99 (<)  
199.9 (<)  
1999 (<)  
19.99 (<)  
BQ TRX  
Resis-  
tance  
150 ppm/ꢀC  
(<) It is possible to modify the decimal point position.  
Input impedances and overloads  
Module  
Inputs  
Type  
Impedance  
Overload (continuous)  
Overloads (1s)  
-200µA to +200µA  
-2mA to +2mA  
-20mA to +20mA  
-200mV to +200mV  
-2V to +2V  
DC/AC  
DC/AC  
DC/AC  
DC/AC  
DC/AC  
DC/AC  
2.2kΩ  
22Ω  
5mA  
50mA  
50mA  
10V  
50V  
50V  
10mA  
150mA  
150mA  
20V  
100V  
100V  
BQ LSX/  
BQ LSE/  
BQ LSF  
22Ω  
2.2kΩ  
200kΩ  
200kΩ  
-20V to +20V  
-200mA to +200mA  
-2A to +2A  
DC/AC  
DC/AC  
DC/AC  
DC/AC  
DC/AC  
DC/AC  
1Ω  
0.012Ω  
0.012Ω  
2MΩ  
0.8A  
7.5A  
7.5A  
750V  
750V  
750V  
1A  
100A  
100A  
1000V  
1000V  
1000V  
-5A to +5A  
BQ HSX  
-20V to +20V  
-200V to +200V  
-500V to +500V  
2MΩ  
2MΩ  
-50ꢀC to +760ꢀC  
-58 ꢀF to +1400 ꢀF  
-200ꢀC to +1260ꢀC  
-328 ꢀF to +2000ꢀF  
-200ꢀC to +1000ꢀC  
-328ꢀF to +1832ꢀF  
-50ꢀC to +1750ꢀC  
-58ꢀF to +2000ꢀF  
-200ꢀC to +400ꢀC  
-328ꢀF to +752ꢀF  
J
J
K
K
E
E
S
S
T
T
BQ TRX  
Thermo-  
couple  
ILK <0.5µA  
Max 5V  
Max 10V  
-200ꢀC to +850ꢀC  
-328ꢀF to +1562ꢀF  
-200.0ꢀC to +200.0ꢀC  
-328ꢀF to +392ꢀF  
Pt100  
Pt100  
Pt250/Pt100  
Pt250/Pt100  
800µA (*)  
800µA (*)  
90µA (*)  
BQ TRX  
Thermo-  
resistance  
90µA (*)  
Max 5V  
Max 5V  
Max 10V  
Max 10V  
-200.0ꢀC to+200.0ꢀC Pt1000/Pt500  
800µA (*)  
800µA (*)  
800µA (*)  
800µA (*)  
-328ꢀF to +392ꢀF  
-60ꢀC to +180ꢀC  
-76ꢀF to +356ꢀF  
Pt1000/Pt500  
Ni100  
Ni100  
0 to 20Ω  
0 to 200Ω  
0 to 2000Ω  
0 to 20.00kΩ  
800µA (*)  
90µA (*)  
800µA (*)  
90µA (*)  
BQ TRX  
Resistance  
(*) Maximum measuring current generated for resistance equal to 0.  
Specifications are subject to change without notice UDM35DS 040706  
3
UDM35  
Output specifications  
RS422/RS485  
Serial output  
LED  
(on request)  
Relay output BO R1, R2, R4  
Relay output BOR5  
Insulation  
Type SPDT  
Module: BR SX  
AC 1: 8A, 250VAC  
DC 12: 5A, 24VDC  
AC 15: 2,5A, 250VAC  
DC 13: 2,5A, 24VDC  
Type SPDT (normally open)  
AC 1: 5A, 250VAC  
DC 12: 3A, 24VDC  
AC 15: 1,5A, 250VAC  
DC 13: 1,5A, 24VDC  
4000 VRMS output to  
measuring input,  
4000 VRMS output to  
power supply input.  
NPN transistor type  
VON 1.2 VDC/ max. 100 mA  
VOFF 30 VDC max.  
Bidirectional (static and  
dynamic variables).  
Display of data  
reception/transmission  
Multidrop, 2 or 4 wires  
1000m  
Directly on the module  
by means of jumper  
1 to 255,selectable  
by means of key-pad  
MODBUS RTU/JBUS  
Connections  
Distance  
Terminalization  
Addresses  
Protocol  
Data (bidirectional)  
Dynamic (reading only)  
Measurement, min value  
max value  
alarm status  
All programming parameters,  
min max reset  
reset of latch alarm  
8 data bit, no parity,  
1 stop bit  
selectable 4800, 9600,  
19200 and 38400 bit/s  
By means of opto-couplers  
4000 Vrms output to  
measuring inputs  
4000 Vrms output to  
power supply input  
Open collector output  
Insulation  
Static (reading/writing)  
By means of opto-couplers,  
4000 VRMS output to  
measuring input,  
4000 VRMS output to power  
supply input  
Data format  
Baud rate  
Insulation  
Analogue output  
(on request)  
Module: BO AV  
Range  
Scaling factor  
0 to 20 mADC, 0 to 10 VDC  
Programmable within the  
whole retransmission range;  
it allows to manage the  
retransmission of all values  
from 0 to 20 mA / 0 to 10V  
0.2% FS (@ 25ꢀC 5ꢀC)  
10 ms  
200 ppm/ꢀC  
700 Ω  
10 kΩ  
By means of optocouplers  
4000Vrms output to measuring  
input  
RS232  
(on request)  
Module: BR SY  
Accuracy  
Serial output  
Bidirectional (static and  
dynamic variables)  
3 wires,  
Response time  
Temperature drift  
Load: 20 mA output  
10 V output  
Connections  
Distance  
Data format  
max. 15m  
1 start bit, 8 data bit,  
no parity, 1 stop bit  
Selectable 4800, 9600,  
19200 and 38400 bit/s  
Same as RS422/485  
Insulation  
Baud rate  
4000V output to power  
rms  
Other features  
supply input  
The two outputs cannot be  
used at the same time  
Alarm outputs  
Alarm type  
(on request)  
Active alarm for out-of-range,  
up alarm,  
down alarm,  
down alarm with  
start-up deactivation,  
up alarm with latch,  
down alarm with latch  
Adjustable from 0 to 100%  
of displayed electric range  
0 to 100% of displayed range  
0 to 255 s  
Notes:  
Excitation output  
BQ LSE module  
Voltage  
(on request)  
13 VDC 10%  
max. 50 mA  
Insulation  
25Vrms output to  
measuring input  
4000 Vrms output to  
power supply input  
Alarm set-point  
Hysteresis  
BQ LSF module  
Voltage  
On-time delay  
Off-time delay  
Output status  
25 VDC 10%  
0 to 255 s  
Selectable: normally  
max. 25 mA  
energized/de-energized  
500 ms, with filter excluded,  
without alarm activation delay  
1 with BO R1 module (relay  
output).  
Insulation  
25Vrms output to  
measuring input  
4000 Vrms output to  
power supply input  
Min response time  
Output channels  
2, independent with module  
BO R2 (2 relay outputs).  
4, independent with BO R4  
module (2 relay outputs +  
2 open collector outputs).  
BOR5 (4 relay outputs)  
4
Specifications are subject to change without notice UDM35DS 040706  
UDM35  
Software functions  
Min / Max storage  
Automatic storage  
Diagnostics  
The display flashes when the  
limits of the display range  
are exceeded and the data  
are updated up to 20%  
of the rated display range.  
Only temperature inputs.  
Opening of probe’s  
connection: EEE indication  
Opening of probe’s  
connection: EEE indication  
probe’s short circuit:  
(in the EEPROM) of the  
minimum and maximum  
measured value from the  
previous memory reset  
Burn-out:  
TC  
Password  
Numeric code max 4 dgt  
2 levels of data protection.  
0 to 4999 completely protected.  
5000 to 9999 access to  
programming is protected .  
Alarm set-points are directly  
programmable from the  
measuring mode.  
1st level  
2nd level  
RTD  
-EEE indication.  
Digital filter  
Filter operating range  
Filtering coefficient  
0 to 1999  
1 to 32  
Measurement selection  
Integration time selection  
Depending on the module:  
measuring range and type of  
probe (resistance, RTD  
thermoresitance,  
TC thermocouple) or  
measuring type (TRMS or DC).  
Display selection  
3 1/2 DGT or 3 DGT plus  
dummy zero  
Scaling  
Selection of min value  
of the input range.  
Selection of max value of  
the input range.  
Selection of decimal point  
position.  
Automatic or from 100.0 to  
999.9 ms only in the current  
and voltage measurement.  
Scaling factor  
Operating mode  
Selection of min  
Electrical scale compression,  
displayed scale  
compression/expansion  
(max. 2 without filter, up to  
10 with filter)  
Programmable within the  
whole measuring range  
Programmable within the  
display range  
displayable value.  
Selection of max displayable  
value.  
UdmSoft  
Software for programming  
UDM35 by means of PC  
(Windows 95, 98se, ME, XP)  
by means of serial port  
RS485 and relevant  
Electrical range  
Decimal point position  
Displayed range of the variable Programmable within  
the display range  
connection cable.  
The software is available in  
English, Spanish, Italian,  
German and French. See  
also “Programming of  
UDM35 by means of PC”.  
General Specifications  
Operating  
temperature  
0ꢀ to 50ꢀC (32ꢀ to 122ꢀF)  
(R. H. < 90% non-condensing)  
Safety Standards  
Safety  
EN 61010-1, IEC 61010-1  
Storage  
temperature  
-10ꢀ to 60ꢀC (14ꢀ to 140ꢀF)  
(R.H. < 90% non-condensing)  
Connections  
Wire section  
Screw type  
Max 2.5mm2  
Insulation reference  
voltage  
Insulation  
300 VRMS to ground  
(500V input)  
Housing  
Dimensions  
Material  
1/8 DIN, 48 x 96 x 105 mm  
PC-ABS,  
self-extinguishing: UL 94 V-0  
See table “Insulation between  
inputs and outputs”  
Protection degree  
Weight  
Front: IP67, NEMA4x  
Connections: IP20  
Dielectric strength  
Rejection  
NMRR  
4000 VRMS for 1 minute  
520 g approx (included all  
modules and packing)  
40 dB, 40 to 60 Hz  
100 dB, 40 to 60 Hz  
CMRR  
Approvals  
CE, UR, CSA  
EMC  
EN61000-6-2, IEC61000-6-2  
EN61000-6-3, IEC61000-6-3  
Specifications are subject to change without notice UDM35DS 040706  
5
UDM35  
Supply Specifications  
AC/DC voltage  
90 to 260V (standard)  
18 to 60V (on request)  
Energy consumption  
30VA/12W (90 to 260V)  
20VA/12W (18 to 60V)  
Excitation output  
Insulation between inputs and outputs  
Meas. Relay Static Analogue Serial  
inputs output output output Port p.supply  
AUX  
90-260VAC/  
DC p.supply  
18-60VAC/  
DC p.supply  
V
Meas.  
inputs  
-
4kV  
-
4kV  
2kV  
-
4kV  
4kV  
4kV  
-
4kV  
4kV  
4kV  
4kV  
-
25V  
4kV  
4kV  
4kV  
4kV  
-
4kV  
4kV  
4kV  
4kV  
4kV  
4kV  
-
4kV  
4kV  
4kV  
4kV  
4kV  
4kV  
-
30  
Continuous  
max. 30 s.  
Relay  
4kV  
4kV  
4kV  
4kV  
25V  
4kV  
4kV  
25  
Output  
Static  
2kV  
4kV  
4kV  
4kV  
4kV  
4kV  
20  
Output  
Analogue  
Output  
4kV  
4kV  
4kV  
4kV  
4kV  
15  
BQ LSE  
Serial  
Port  
4kV  
4kV  
4kV  
4kV  
10  
AUX  
4kV  
4kV  
4kV  
5
p.supply  
90-260VAC/  
0
4kV  
4kV  
DCp..supply  
mA  
60  
10  
20  
30  
40  
50  
18-60V AC/  
DC p. supply  
-
-
Available modules  
Possible module combinations  
N. of  
channels  
Basic Unit  
Measuring inputs:  
Slot A Slot B Slot C Slot D  
Type  
Ordering  
code  
LSX, LSE, LSF, HSX, TRX  
UDM35 main unit  
BD 35  
DC/AC input: 200µA , 2mA, 20mA,  
200mA, 2V, 20V  
DC/AC input: 200µA , 2mA, 20mA,  
200mA, 2V, 20V + excitation output  
DC/AC input: 200mA, 2A, 5A,  
20V, 200V, 500V  
RS485 Serial port: SX  
RS232 Serial port: SY  
Analogue output: AV (*)  
1
1
1
BQ LSX  
BQ LSE/  
BQ LSF  
Relay outputs and/or open  
collector: R1, R2, R4, R5  
BQ HSX  
Input: 20Ω, 200Ω, 2kΩ, 20kΩ  
TC: J-K-S-T-E, Pt100-250-500-1000  
Analogue output 0 to 20mA, 0 to 10VDC  
Relay output  
1
1
1
1
2
4
4
1
1
BQ TRX  
BQ TRX  
BO AV  
BO R1  
BO R2  
BO R4  
BO R5  
BR SX  
BR SY  
BP L  
Power supply: H, L  
(*) Up to 1 module max.  
Used calculation formulas  
Only for TRMS Measurements  
Relay output  
Outputs: 2 relays + 2 open collectors  
Relay output  
n
1
2
V
=
×
(V )  
1
Instantaneous effective  
voltage (TRMS)  
å
1
i
RS485 Serial Port  
RS232 Serial Port  
n
1
Power supply 18 to 60V AC/DC  
Power supply 90 to 260V AC/DC  
n
1
2
BP H  
Instantaneous effective  
current (TRMS)  
A
=
×
( A )  
1
å
1
i
n
1
6
Specifications are subject to change without notice UDM35DS 040706  
UDM35  
Wiring diagrams  
Process signal wiring diagrams  
BQ LSX/LSE/LSF  
BQ LSX/LSE/LSF  
BQ LSE/LSF  
Fig. 1  
Fig. 2  
Fig. 3  
+
-
+ Vdc  
-
+
˜
-
˜
+
˜
-
˜
Voltage measurements  
4-wire connection to probe  
Current measurements  
Voltage measurements  
BQ LSE/LSF  
BQ LSE/LSF  
BQ LSE/LSF  
Fig. 4  
Fig. 5  
Fig. 6  
-
+
+
+
+ Vdc  
-
+ Vdc  
+ Vdc  
-
-
Voltage measurements  
Current measurements  
Current measurements  
3-wire connection to probe  
4-wire connection to probe  
3-wire connection to probe  
Wirings for high-level signals  
BQ LSE/LSF  
BQ HSX  
BQ HSX  
Fig. 7  
Fig. 8  
Fig. 9  
+
+ Vdc  
+
-
˜
+
˜
-
˜
Current measurements  
2-wire connection to probe  
˜
Current measurements  
Voltage measurements  
Specifications are subject to change without notice UDM35DS 040706  
7
UDM35  
Wiring diagrams (cont.)  
Wiring diagrams for temperature measurements  
BQ TRX  
BQ TRX  
BQ TRX  
Fig. 10  
Fig. 11  
Fig. 12  
Temp. measur. from thermoresistance  
Temp. measur. from thermocouple  
Resistance measurements  
Wiring diagrams for power supply  
BP H: power supply  
BP L: power supply  
F1= 630mA T  
250V 5x20mm  
F1= 3.15A T  
250V 5x20mm  
Wiring diagrams of optional modules  
BO AV: analogue output  
(10V, 20mA DC)  
BO R1: 1 relay output  
BO R2: 2 relay outputs  
BO R5: 4 relay outputs  
8
Specifications are subject to change without notice UDM35DS 040706  
UDM35  
Wiring diagrams of optional modules (cont.)  
BO SY: RS232 direct  
connection to PC by  
means of COM port.  
RS232 has no termi-  
nalization.  
SY  
LED  
5
2
3
GND  
RX  
3
2
1
5
1
9
6
Vdc  
TX  
BO R4: dual relay output + dual open collector output: the load resistances (Rc) must be designed so that the close  
contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30VDC.  
VDC: power supply output  
Vo+: positive output (open collector transistor).  
GND: ground collector (open collector transistor).  
RS1,2,3...N  
NON terminalized network  
Terminalized network  
BR SX: RS485 4-wire connection: additional devices provided with RS485 port (indicated as RS1,2,3...N) are connected  
in parallel. The termination of the serial port is carried out only on the last instrument of the network. The serial module is  
provided with a jumper for the termination of the RS485 network as shown in the figure above.  
Note: particular types of cables or plants may require an external termination. For the network connections use twisted  
cable type AWG26.  
Programming UDM35 by means of PC  
To UDM  
1
UDM35 is programmable by PC by means of the UdmSoft software (available on  
request). The user can program all parameters of UDM35 that will be subse-  
quently uploaded and set in the instrument by the RS485 network (BRSX).  
Should UDM35 be without the RS485 serial module, all programming parameters  
will be uploaded and set in the instrument by the RS232 auxiliary serial connec-  
tion (1) located on the side of the measuring input module using the special con-  
nection cable (2) available on request, as shown in the figures on the left. It is  
also possible to program the instrument using the dot connector (1) by means of  
the HyperTerminal Windows functions of a PC.  
Note: the RS232 auxiliary port IS NOT insulated from the measuring inputs.  
2
Ordering code of the cable (2): UCOM1  
To PC  
Specifications are subject to change without notice UDM35DS 040706  
9
UDM35  
Front panel description  
:
- to program values;  
- to select functions;  
- to scroll display pages.  
: for special functions.  
2. Display  
Instantaneous measurements:  
- 3 1/2 digit (max display 1999).  
Alphanumeric indications by means of LED display for:  
- Display of configuration parameters;  
- The measured variable.  
2
4
3
1
3. Alarm status LED  
1. Key-pad  
Display any alarm condition  
The programming of the configuration parameters and the  
display may be easily controlled by means of the 4 function  
keys.  
: to enter the programming phase and to confirm the  
password.  
4. Engineering unit  
The instrument is supplied with a complete set of  
self-sticking labels with the main engineering units.  
Dimensions  
Engineering Units  
11mm  
105mm  
48mm  
96mm  
45mm -0,3/+0,6  
92mm -0,3/+0,8  
Panel depth: 8mm max.  
10  
Specifications are subject to change without notice UDM35DS 040706  
UDM35  
Modules  
Input modules  
Output modules  
Scale 1:1  
BO AV  
Single analogue  
output 10V, 20mA DC  
BQ LSX, BQ LSE, BQ  
LSF, BQ HSX, BQ TRX  
Measuring inputs  
Output modules  
BO R5  
BO R1  
BO R2  
BO R4  
4 relay outputs  
Single relay output  
Dual relay output  
Dual relay output +  
Dual open collector  
Serial port modules  
Power supply modules  
BR SX  
BP H  
BP L  
BR SY  
RS485 Serial port  
Power supply:  
Power supply:  
RS232 Serial port  
60 to 260V AC/DC  
18 to 60V AC/DC  
Specifications are subject to change without notice UDM35DS 040706  
11  

相关型号:

UDM35HSXSYR5HTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35HSXSYR5LTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35LSESXR1HTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35LSESXR1LTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35LSESXR2HTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35LSESXR2LTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35LSESXR4HTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35LSESXR4LTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35LSESXR5HTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35LSESXR5LTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35LSESYR1HTX

Digital Panel Meters Modular Indicator and Controller
ETC

UDM35LSESYR1LTX

Digital Panel Meters Modular Indicator and Controller
ETC