UHJ-M [ETC]
BUSS CABLE LIMITER;型号: | UHJ-M |
厂家: | ETC |
描述: | BUSS CABLE LIMITER 限制器 |
文件: | 总5页 (文件大小:1169K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Effective February 2019
Supersedes October 2017
Technical Data 1042
250 V and 600 V cable limiters
Features and benefits:
•
Cable limiters enhance multi-conductor system
reliability by isolating faulted conductors and
taking them offline while the balance of the
conductors continue delivering power to their
circuits. This is why cable limiters are often
used in utility low voltage networks and large
multi-cable per phase service entrances.
•
•
Cable limiters enhance service entrance
conductor short-circuit protection with current-
limiting performance that exceed the typical
protection offered by utility overcurrent
protective devices.
Cable limiters meet many system requirements
with 250 Vac or 600 Vac ratings for conductor
sizes from 12 AWG to 1000 kcmil and terminal
options available that make them easy to install
including:
•
•
•
•
•
Tube-to-tube (crimp)
Tube-to-offset bolt (crimp/bolt-in)
Tube-to-center bolt (crimp/bolt-in)
Compression rod-to-tube (crimp)
Bolt-to-offset bolt (bolt-in)
Product description:
Cable limiters are intended to provide short-circuit
protection to electrical systems, typically between
the transformer and service entrance. Should a
short-circuit occur, the cable limiter removes the
affected cable(s) from service and permits the
other conductors to continue delivering power.
•
Select cable limiters are UL Listed under File
E90818 for use on 600 V circuit for protection
against faults up to 200 kA.
Cable limiters are often used in utility low voltage
networks and large multi-cable per phase service
entrances.
Unlike fuses, cable limiters are selected by cable
size rather than amp rating, e.g., a “4/0” limiter
will carry the current of a 4/0 cable.
Limiters are stable, totally self-contained, static
devices with unchanging characteristics that
operate without venting ionized gases or explosive
action.
Under high short-circuit conditions, limiters cut off
fault currents within one-half cycle (0.008 second)
and reduce insulation damage from the immense
heat that is developed by sustained fault current
flow. They confine damage to the point of the
short-circuit and stop long-length cable burn-back
and striking of multiple arcs. This minimizes or
eliminates damage to adjacent conductors.
Technical Data 1042
Cable limiters
Effective February 2019
250V UH Series
Catalog Symbol
•
UH__
Applications
•
The 250 Vac UH cable limiters are designed specifically for use in
residential applications.
Ratings
•
Volts: up to 250 Vac
•
Interrupting rating: 100 kA, RMS Sym.
Terminals
•
Center bolt-to-offset bolt — copper or aluminum conductors
Conductors
•
Copper or aluminum conductors are permitted per the listed cable
size. Select the catalog number for the system conductor size in
the table below.
Dimensions — in (mm)
H
G
F
C
A1
A2
B
D
Bolt
terminal
detail
I
E
E
Catalog
no.
Copper
Aluminum
cable size cable size
A1
A2
B
C
D
E
F
G
H
I
UHA
2/0 AWG
3/0 AWG
350 kcmil
600 kcmil
4/0 AWG
250 kcmil
500 kcmil
800 kcmil
1.06 (27.0)
1.19 (30.2) 1.44 (36.5) 1.00 (25.4) 0.75 (19.0) 0.12 (3.2)
0.56 (14.3) 0.19 (4.8)
0.87 (22.2) 0.34 (8.6)
0.87 (22.2) 0.34 (8.6)
0.87 (22.2) 0.34 (8.6)
0.59 (15.1) 0.41 (10.3)
0.69 (17.5) 0.56 (14.3)
0.69 (17.5) 0.56 (14.3)
0.69 (17.5) 0.56 (14.3)
UHJ-M
UHJ-T
UHJ-W
1.53 (38.9) 1.75 (44.4) 1.59 (40.5) 1.50 (38.1) 1.00 (25.4) 0.25 (6.3)
1.53 (38.9) 1.75 (44.4) 1.59 (40.5) 1.50 (38.1) 1.00 (25.4) 0.25 (6.3)
1.53 (38.9) 1.75 (44.4) 1.59 (40.5) 1.50 (38.1) 1.00 (25.4) 0.25 (6.3)
2
Eaton.com/bussmannseries
Cable limiters
Technical Data 1042
Effective February 2019
600V K Series
Catalog Symbol
Available terminals
•
•
K__
Tube-to-tube
•
Applications
Tube-to-offset bolt
•
Compression rod-to-tube
The 600 Vac K cable limiters are designed for use on non-residential
277/480, 120/208 and 120/240 volt systems.
•
Center bolt-to-offset bolt
Ratings
•
Center bolt-to-tube
•
Volts: up to 600 Vac
Conductors
•
Interrupting rating: 200 kA, RMS Sym.
•
Copper or aluminum based upon terminal style and perrmitted
conductor material. See catalog number tables for details
Agency information
•
UL Listed, File E90818, 600 Vac, 200 kA IR on catalog numbers
CDA-W, CDB-W, KCD, KCJ, KCM, KCM-B, KCR, KDD, KDF, KDJ,
KDM, KDP, KDR, KDU, KEW, KFM, KFT, KHF, KHJ, KHM, KHR,
KQT
Dimensions — in (mm)
A
A
C
B
E
D
Tube-to-tube terminals:
•
Copper or aluminum conductor — see catalog number table for details
Catalog number
KCY
Copper cable size Aluminum cable size
A
B
C
D
E
4 AWG
3 AWG
—
1.25 (31.8)
1.25 (31.8)
1.25 (31.8)
1.25 (31.8)
1.5 (38.1)
1.63 (41.3)
1.63 (41.3)
1.75 (44.5)
1.88 (47.6)
2.0 (50.8)
2.88 (73.0)
3.5 (88.9)
3.5 (88.9)
4.0 (102)
2.88 (73.0)
2.88 (73.0)
2.88 (73.0)
2.88 (73.0)
2.625 (66.7)
2.625 (66.7)
3.63 (92.1)
3.63 (92.1)
3.63 (92.1)
3.63 (92.1)
3.08 (78.2)
3.08 (78.2)
3.75 (95.25)
3.01 (78)
1.06 (27.0)
1.06 (27.0)
1.06 (27.0)
1.06 (27.0)
1.25 (31.8)
1.25 (31.8)
1.44 (36.5)
1.44 (36.5)
1.44 (36.5)
1.63 (41.3)
1.88 (47.6)
1.88 (47.6)
2.5 (63.5)
1.88 (47.6)
2.5 (63.5)
0.31 (7.9)
0.34 (8.7)
0.44 (11.1)
0.47 (11.9)
0.52 (13.1)
0.44 (14.3)
0.61 (15.5)
0.34 (17.5)
0.75 (19.0)
0.88 (22.2)
1.06 (27.0)
1.155 (29.3)
1.31 (33.3)
1.59 (40.5)
1.56 (39.7)
0.25 (6.4)
0.28 (7.1)
0.31 (7.9)
0.34 (8.7)
0.39 (9.9)
0.70 (11.1)
KCZ
—
KCA
2 AWG
—
KCB
1 AWG
—
KCC
KCD*, †
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
—
—
—
KCE
—
0.48 (12.3)
0.55 (14.0)
0.59 (15.0)
0.70 (17.9)
0.83 (21.0)
0.92 (23.4)
1.06 (27.0)
1.03 (26.2)
1.22 (31.0)
KCF
—
KCH
—
KCJ*†
KCM*, †, ††
KCV
KCR*, †
CDA-W*
KCS
—
—
—
—
750 kcmil
—
1000 kcmil
5.0 (127.0)
3.75 (95.25)
* UL Listed, File E90818, 600 Vac, 200 kA IR.
† Available with shrink tube “–V” suffix.
††Available with molded rubber boot “-B” suffix. Order catalog no. “KCM-B.” Boot can be purchased separately, order Part# - BOOT-KCM
Dimensions — in (mm)
A
B
C
D
F
E
Compression rod-to-tube terminals
G
•
Copper conductor only
Catalog no.
KEX
Copper cable size
4/0 AWG
A
B
C
D
E
F
G
2.5 (63.5)
2.5 (63.5)
2.5 (63.5)
2.5 (63.5)
3.63 (92.1)
3.63 (92.1)
3.63 (92.1)
3.08 (78.2)
1.75 (44.5)
1.88 (47.6)
2.0 (50.8)
2.88 (73.0)
1.44 (36.5)
1.44 (36.5)
1.63 (41.3)
1.88 (47.6)
0.69 (17.5)
0.75 (19.0)
0.88 (22.2)
1.06 (27.0)
0.55 (13.9)
0.28 (15.1)
0.70 (17.8)
0.83 (21.0)
0.5 (12.7)
0.56 (14.3)
0.81 (20.6)
0.81 (20.6)
KFH-A
KQO
250 kcmil
350 kcmil
KDT
500 kcmil
Eaton.com/bussmannseries
3
Technical Data 1042
Cable limiters
Effective February 2019
0.125"
(3.18mm)
Dimensions — in (mm)
1.63"
0.56"
(41.3mm)
(14.3mm)
A
F
C
B
G
J
Bolt
terminal
detail
E
D
H
0.56"
(14.3mm)
Tube-to-offset bolt terminals:
•
Copper or aluminum conductor — see catalog number table for details
Catalog
symbol
Copper
Aluminum
cable size cable size
A
B
C
D
E
F
G
H
J
KQV
12 AWG
10 AWG
8 AWG
—
1.25 (31.8)
1.25 (31.8)
1.25 (31.8)
1.25 (31.8)
1.25 (31.8)
1.25 (31.8)
1.25 (31.8)
1.5 (38.1)
2.88 (73.0)
2.88 (73.0)
2.88 (73.0)
2.88 (73.0)
2.88 (73.0)
2.88 (73.0)
2.88 (73.0)
1.06 (27.0)
1.06 (27.0)
1.06 (27.0)
1.06 (27.0)
1.06 (27.0)
1.06 (27.0)
1.06 (27.0)
0.19 (4.8)
0.23 (6.0)
0.23 (6.0)
0.31 (7.9)
0.125 (3.2)
0.14 (3.6)
0.16 (4.0)
0.16 (4.0)
0.25 (6.4)
0.31 (7.9)
3.31 (84.1)
3.31 (84.1)
3.31 (84.1)
3.31 (84.1)
3.31 (84.1)
3.31 (84.1)
3.31 (84.1)
3.38 (85.7)
3.38 (85.7)
3.38 (85.7)
3.38 (85.7)
3.38 (85.7)
3.38 (85.7)
3.38 (85.7)
3.5 (88.9)
0.72 (18.3)
0.72 (18.3)
0.72 (18.3)
0.72 (18.3)
0.72 (18.3)
0.72 (18.3)
0.72 (18.3)
0.88 (22.2)
0.88 (22.2)
0.97 (24.6)
0.97 (24.6)
0.97 (24.6)
1.06 (27.0)
1.19 (30.2)
1.5 (38.1)
0.19 (4.8)
0.19 (4.8)
0.19 (4.8)
0.19 (4.8)
0.19 (4.8)
0.19 (4.8)
0.19 (4.8)
0.25 (6.4)
0.25 (6.4)
0.25 (6.4)
0.25 (6.4)
0.25 (6.4)
0.25 (6.4)
0.25 (6.4)
0.25 (6.4)
0.25 (6.4)
0.25 (6.4)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.63 (41.3)
KQT*
KFZ
—
—
KIG
6 AWG
—
KDY
4 AWG
—
0.31 (7.9)
KDA
2 AWG
—
0.44 (11.1)
0.47 (11.9)
0.52 (13.1)
0.56 (14.3)
0.61 (15.5)
0.69 (17.5)
0.75 (19.0)
0.88 (22.2)
1.06 (27.0)
1.16 (29.4)
1.6 (40.5)
1.31 (33.3)
KDB
1 AWG
—
0.34 (8.7)
0.39 (9.9)
0.44 (11.1)
0.48 (12.3)
0.55 (13.9)
0.59 (15.0)
0.70 (17.8)
0.83 (21.0)
0.92 (23.4)
1.03 (26.2)
1.06 (27.0)
KDC
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 kcmil
350 kcmil
500 kcmil
600 kcmil
—
—
2.625 (66.7) 1.25 (31.8)
KDD*
KDE
—
1.63 (41.3) 2.625 (66.7) 1.25 (31.8)
—
1.63 (41.3)
1.75 (44.5)
1.88 (47.6)
2.0 (50.8)
2.88 (73.0)
3.5 (88.9)
4.0 (102)
3.63 (92.1)
3.63 (92.1)
3.63 (92.1)
3.63 (92.1)
3.08 (78.2)
3.75 (95.2)
3.08 (78.1)
3.75 (95.2)
1.44 (36.5)
1.44 (36.5)
1.44 (36.5)
1.63 (41.3)
1.88 (47.6)
2.5 (63.5)
1.88 (47.6)
2.5 (63.5)
KDF*
KDH
—
—
KDJ*, †
KDM*,†
KDU*
CDB-W*
KDR*, ††
—
—
—
2.0 (50.8)
750 kcmil
—
3.38 (85.7)
3.5 (88.9)
1.19 (30.2)
1.5 (38.1)
1.63 (41.3)
750 kcmil
3.5 (88.9)
2.0 (50.8)
* UL Listed, File E90818, 600 Vac, 200 kA IR.
† Available with molded rubber boot “-B” suffix. Boot can be purchased separately, order Part# - BOOT-KDM
††Available with shrink tube “–V” suffix.
Dimensions — in (mm)
0.125 (3.18)
0.56 (14.3)
H
A
B
C
D
1.63 (41.3)
F
E
G
Ø 0.56 (14.3)
0.56 (14.3)
Center bolt-to-tube terminals
Bolt terminal detail
•
Copper conductor only
Catalog no.
KHF*
Copper cable size
4/0 AWG
A
B
C
D
E
F
G
H
3.38 (85.8)
3.38 (85.8)
3.38 (85.8)
3.5 ((88.9)
3.63 (92.2)
3.63 (92.2)
3.08 (78.2)
3.88 (98.5)
1.75 (44.4)
1.44 (36.7)
1.63 (41.4)
1.88 (47.7)
2.5 (63.5)
0.69 (17.5)
0.88 (22.3)
1.05 (26.7)
1.31 (33.3)
0.48 (12.2)
1.13 (28.7)
1.13 (28.7)
1.13 (28.7)
2.0 (50.8)
0.25 (6.3)
0.25 (6.3)
0.25 (6.3)
0.25 (6.3)
KHJ*
350 kcmil
2 (50.8)
0.7 (17.8)
KHM*
500 kcmil
2.88 (73.1)
3.5 (88.9)
0.83 (21.1)
1.06 (26.9)
KHR*
750 kcmil
* UL Listed for copper only, File E90818, 600 Vac, 200 kA IR.
0.125"
Dimensions — in (mm)
(3.18mm)
1.63"
0.56"
F
(41.3mm)
(14.3mm)
C
A
A
B
D
E
Bolt
terminal
detail
0.25"
(6.4mm)
0.25"
Center bolt-to-offset bolt terminals
0.56"
(14.3mm)
(6.4mm)
•
Copper or aluminum conductor — see catalog number table for details
Catalog no.
KPF
Copper cable size
4/0 AWG
Aluminum cable size
4/0 AWG
A
B
C
D
E
F
3.38 (85.7)
3.38 (85.7)
3.38 (85.7)
3.38 (85.7)
3.50 (88.9)
3.63 (92.1)
3.63 (92.1)
3.63 (92.1)
3.08 (78.2)
3.75 (95.3)
1.44 (36.5)
1.44 (36.5)
1.63 (41.3)
1.88 (47.6)
2.50 (63.5)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.5 (38.1)
1.125 (28.6)
1.125 (28.6)
1.125 (28.6)
1.63 (41.3)
0.97 (24.6)
0.97 (24.6)
1.06 (27.0)
1.19 (30.2)
1.50 (38.1)
KFT*
250 kcmil
250 kcmil
KEW*
KDP*
350 kcmil
350 kcmil
500 kcmil
500 kcmil
KFM*
750 kcmil
750 kcmil
2.0 (50.8)
2.00 (50.8)
* UL Listed for copper only, File E90818, 600 Vac, 200 kA IR.
4
Eaton.com/bussmannseries
Technical Data 1042
Cable limiters
Effective February 2019
Peak let-through current
Time-current characteristics - total clear
1000 kcmil
750 kcmil
500 kcmil
350 kcmil
250 kcmil
4/0 AWG
3/0 AWG
2/0 AWG
1/0 AWG
1 AWG
B
Cable
Size
100,000
100
2 AWG
3 AWG
4 AWG
6 AWG
10,000
8 AWG
10 AWG
12 AWG
Cable
Size
10
1000
A
100
1
Prospective Short-Circuit Current
Symmetrical RMS Amps
0.1
0.01
Current in Amps
The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are
by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the
end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit
distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once
a product has been selected, it should be tested by the user in all possible applications.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
Eaton.com
Bussmann Division
114 Old State Road
Ellisville, MO 63021
United States
Eaton.com/bussmannseries
Eaton and Bussmann are valuable trademarks
of Eaton in the U.S. and other countries. You
are not permitted to use the Eaton trademarks
without prior written consent of Eaton.
Follow us on social media to get the
latest product and support information.
© 2019 Eaton
All Rights Reserved
Printed in USA
Publication No. 1042 — BU-SB14632
February 2019
UL is a registered trademark of the
Underwriters Laboratories, Inc.
相关型号:
UHM-S055B0-5AP1-KR
105 CONTACT(S), FEMALE, RIGHT ANGLE TWO PART BOARD CONNECTOR, PRESS FIT, SOCKET, ROHS COMPLIANT
3M
UHM-S055B0-5AP1-TR30
HEADER CONNECTOR,PCB MNT,55 CONTACTS,SKT,0.079 PITCH,COMPLIANT FIT TERMINAL,LOCKING
3M
UHM-S055B3-5AP1-KR
105 CONTACT(S), FEMALE, RIGHT ANGLE TWO PART BOARD CONNECTOR, PRESS FIT, SOCKET, ROHS COMPLIANT
3M
UHM-S055B3-5AP1-TR30
HEADER CONNECTOR,PCB MNT,55 CONTACTS,SKT,0.079 PITCH,COMPLIANT FIT TERMINAL,LOCKING
3M
UHM-S055CL0-5AP1-KR
HEADER CONNECTOR,PCB MNT,55 CONTACTS,SKT,0.079 PITCH,COMPLIANT FIT TERMINAL,GUIDE PIN
3M
UHM-S055CL0-5AP1-TR30
HEADER CONNECTOR,PCB MNT,55 CONTACTS,SKT,0.079 PITCH,COMPLIANT FIT TERMINAL,GUIDE PIN
3M
UHM-S055CL3-5AP1-KR
HEADER CONNECTOR,PCB MNT,55 CONTACTS,SKT,0.079 PITCH,COMPLIANT FIT TERMINAL,GUIDE PIN
3M
UHM-S055CL3-5AP1-TR30
HEADER CONNECTOR,PCB MNT,55 CONTACTS,SKT,0.079 PITCH,COMPLIANT FIT TERMINAL,GUIDE PIN
3M
UHM-S055CR0-5AP1-KR
HEADER CONNECTOR,PCB MNT,55 CONTACTS,SKT,0.079 PITCH,COMPLIANT FIT TERMINAL,GUIDE PIN
3M
UHM-S055CR3-5AP1-KR
HEADER CONNECTOR,PCB MNT,55 CONTACTS,SKT,0.079 PITCH,COMPLIANT FIT TERMINAL,GUIDE PIN
3M
©2020 ICPDF网 联系我们和版权申明