UV28-8-S [ETC]

DC to DC Converter ; 直流到直流转换器\n
UV28-8-S
型号: UV28-8-S
厂家: ETC    ETC
描述:

DC to DC Converter
直流到直流转换器\n

转换器
文件: 总8页 (文件大小:597K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
M
ICRO ERTER DC-DC Converters, 200-250 Watt Family  
V
RO  
Evaluation Boards and Triple Output Modules Available  
World’s Most Advanced Ultra High  
Density Single and Triple Output  
DC-DC Converters  
Up to 252 Watts  
28, 48, and 300 VDC Input  
DESCRIPTION  
MicroVerter modules are high density DC-  
DC converters designed for use in tele-  
com and other centralized modular and  
distributed power applications. Three  
input voltage ranges are available and  
all use metal PC boards, planar transformers,  
and surface mount construction to pro-  
duce up to 252 watts in a tiny package.  
MODEL SELECTION  
Model Number  
FEATURES  
Miniature Size  
Input  
48 VDC  
(36-72V)  
Output  
28 VDC  
(20-32V)  
300 VDC  
(220-400V)  
Voltage Current  
3
High Density – Up to 58 W/in.  
Single Output  
Constant Frequency – 370KHz  
Parallelable with Current Sharing  
Fault Tolerant – n+m Redundancy  
Extremely Low Thermal Resistance  
Output Good Signal  
µV28-2  
µV28-3  
µV28-5  
µV28-8  
µV28-12  
µV28-15  
µV28-24  
µV28-28  
µV48-2  
µV300-2  
µV300-3  
µV300-5  
µV300-8  
µV300-12  
µV300-15  
µV300-24  
µV300-28  
2.1V  
3.3V  
5V  
60A  
50A  
40A  
30A  
20A  
16A  
10A  
9A  
µV48-3  
µV48-5  
µV48-8  
µV48-12  
µV48-15  
µV48-24  
µV48-28  
8V  
12V  
15V  
24V  
28V  
Synchronization Option  
UL, CSA, & TUV Approvals  
Non-Shutdown Over Voltage Protection  
Logic On-Off  
Triple Output  
Thermal Protection  
µV28-T512 µV48-T512 µV300-T512  
5V  
12V  
-12V  
5V  
15V  
-15V  
35A*  
3A*  
3A*  
35A*  
3A*  
3A*  
Current Limit/Short Circuit Protection  
Isolated Auxiliary Outputs  
µV28-T515 µV48-T515 µV300-T515  
Maximum Total Output Power 185 W. (See p. 19 for min. load requirements.)  
*
Option: --S Synchronization Feature  
RO Associates, Inc. • Sunnyvale, CA • 408 744-1450 • Fax: 408 744-1521 • email: sales@roassoc.com  
12  
MICROVERTER® µV28 SERIES SPECIFICATIONS  
INPUT  
Input voltage  
MIN  
20  
TYPICAL  
24-28  
MAX  
32  
UNITS  
VDC  
CONDITIONS  
Brownout  
18  
VDC  
Coulombs  
%
watts  
watts  
watts  
dB  
75% full output power  
In rush charge  
Input reflected ripple  
No load power dissipation  
2.6x10-4  
20  
1.5  
7.5  
0.35  
60  
full load, nominal line  
singles  
triples  
Logic disabled power in  
Input ripple rejection  
Input overvoltage  
@ 120 Hz  
no damage to units  
32  
60  
VDC  
OUTPUT (Singles and Main Output of Triple)  
Set point accuracy  
Load regulation  
Line regulation  
Ripple  
1
.2  
.2  
3
%
%
%
%p-p  
%
no load  
0 to full load  
over range  
0 to 20 MHz  
.02  
.02  
1
Trim range  
10  
consult factory for extended range  
Remote sense compensation  
OVP (non shutdown auto. recovery)  
Current Limit (auto.recovery)  
Current sharing (automatic)  
Transient response singles  
Transient response main output triples  
Transient response (see page 19)  
Temp drift  
0.5  
V total  
%
%
%
µs  
120*  
110-120  
5
50  
200  
* or Vout +.5V whichever is greater  
full load  
full load  
20-80% load,.5A/µs, Vout 1%  
10-20A, aux. loads 2.5A, .25A/µs, Vout 1%  
µs  
.02  
%/°C  
Efficiency (see curves page 17)  
OUTPUT (Auxiliary Outputs of Triples)  
Set point accuracy  
Load regulation  
0.5  
.2  
.01  
1
.5  
.1  
%
%
%
10A on main, no load auxiliaries  
0 to full load  
over range  
Line regulation  
Ripple  
.25  
.5  
%p-p  
%
µs  
µs  
µs  
0 to 20 MHz  
full load  
20-80% load, Vout within 1%  
low line to high line, Vout 1%  
50-100% load, Vout 1%  
Current Limit (auto. recovery)  
Transient response  
Transient response  
Transient response  
Temp drift  
110-120  
200  
200  
200  
.06  
%/°C  
CONTROL  
Turn on time  
2.5  
1
1
ms  
ms  
mA  
input power applied, Vout 1%  
Vout within 1%  
sink  
Logic turn on time  
Logic disabled current  
ISOLATION  
Input to output  
Input to case  
Output to case  
Input to output capacity  
1000  
1000  
200  
VDC  
VDC  
VDC  
pF  
consult factory for procedure  
2200  
THERMAL  
Operating temperature  
-40  
+100  
+100  
+110  
°C case  
°C case  
°C/w  
Automatic shut down temperature  
Thermal resistance case to ambient  
+105  
4.2  
single @ Tc=100°C  
triple @ Tc=100°C  
3.3  
7
9
0.5x2.4x3.6  
0.5x2.4x4.6  
°C/w  
oz.  
oz.  
inches  
inches  
WEIGHT  
SIZE  
singles  
triples  
singles  
triples  
(outline drawings see page 16)  
RO Associates, Inc. • Sunnyvale, CA • 408 744-1450 • Fax: 408 744-1521 • email: sales@roassoc.com  
13  
MICROVERTER® µV48 SERIES SPECIFICATIONS  
INPUT  
Input voltage  
MIN  
36  
TYPICAL  
48  
MAX  
72  
UNITS  
VDC  
CONDITIONS  
Brownout  
32  
VDC  
Coulombs  
%
watts  
watts  
watts  
dB  
75% full output power  
In rush charge  
Input reflected ripple  
No load power dissipation  
2.6x10-4  
20  
2.5  
7.5  
1
full load, nominal line  
singles  
triples  
Logic disabled power in  
Input ripple rejection  
Input overvoltage  
60  
@ 120 Hz  
no damage to unit  
72  
100  
VDC  
OUTPUT (Singles and Main Output of Triple)  
Set point accuracy  
Load regulation  
Line regulation  
Ripple  
1
.2  
.2  
3
%
%
%
%p-p  
%
no load  
0 to full load  
over range  
0 to 20MHz  
.02  
.02  
1
Trim range  
10  
consult factory for extended range  
Remote sense compensation  
OVP (non shutdown auto. recovery)  
Current Limit (auto.recovery)  
Current sharing (automatic)  
Transient response singles  
Transient response main output triples  
Transient response (see page 19)  
Temp drift  
0.5  
V total  
%
%
%
µs  
120*  
110-120  
5
50  
200  
* or Vout +.5V whichever is greater  
full load  
full load  
20-80% load,.5A/µs, Vout 1%  
10-20A, aux. loads 2.5A, .25A/µs, Vout 1%  
µs  
.02  
%/°C  
Efficiency (see curves page 17)  
OUTPUT (Auxiliary Outputs of Triples)  
Set point accuracy  
Load regulation  
Line regulation  
Ripple  
0.5  
.2  
.01  
.25  
1
.5  
.1  
.5  
%
%
%
%p-p  
10A on main, no load auxiliaries  
0 to full load  
over range  
0 to 20 mHz  
Current Limit (auto.recovery)  
Transient response  
Transient response  
Transient response  
Temp drift  
110-120  
%
full load  
200  
200  
200  
.06  
µs  
µs  
µs  
%/°C  
20-80% load, Vout within 1%  
low line to high line, Vout 1%  
50-100% load, Vout 1%  
CONTROL  
Turn on time  
2.5  
1
1
ms  
ms  
mA  
input power applied, Vout 1%  
Vout within 1%  
sink  
Logic turn on time  
Logic disabled current  
ISOLATION  
Input to output  
Input to case  
Output to case  
Input to output capacity  
3000  
1500  
500  
VDC  
VDC  
VDC  
pF  
consult factory for procedure  
2200  
THERMAL  
Operating temperature  
-40  
+100  
+100  
+110  
°C case  
°C case  
°C/w  
Automatic shut down temperature  
Thermal resistance case to ambient  
+105  
4.2  
single @ Tc=100°C  
triple @ Tc=100°C  
3.3  
7
9
0.5x2.4x3.6  
0.5x2.4x4.6  
°C/w  
oz.  
oz.  
inches  
inches  
WEIGHT  
SIZE  
singles  
triples  
singles  
triples  
(outline drawings see page 16)  
RO Associates, Inc. • Sunnyvale, CA • 408 744-1450 • Fax: 408 744-1521 • email: sales@roassoc.com  
14  
MICROVERTER® µV300 SERIES SPECIFICATIONS  
INPUT  
MIN  
220  
180  
TYPICAL  
MAX  
400  
UNITS  
VDC  
VDC  
Coulombs  
%
watts  
watts  
watts  
dB  
CONDITIONS  
Input voltage  
300  
Brownout  
75% full output power  
In rush charge  
Input reflected ripple  
No load power dissipation  
4.5x10-5  
20  
2.5  
7.5  
1
full load, nominal line  
singles  
triples  
Logic disabled power in  
Input ripple rejection (120Hz)  
60  
@ 120 Hz  
OUTPUT (Singles and Main Output of Triple)  
Set point accuracy  
Load regulation  
Line regulation  
Ripple  
1
.2  
.2  
3
%
%
%
%p-p  
%
no load  
0 to full load  
over range  
0 to 20 MHz  
.02  
.02  
1
Trim range  
10  
+10, -30  
consult factory for extended range  
Remote sense compensation  
OVP (non shutdown auto. recovery)  
Current Limit (auto.recovery)  
Current sharing (automatic)  
Transient response singles  
Transient response main output triple  
Transient response (See page 19)  
Temp drift  
0.5  
V total  
%
%
%
µs  
120*  
110-120  
5
50  
200  
* or Vout +.5V whichever is greater  
full load  
full load  
20-80% load,.5A/µs, Vout 1%  
10-20A, aux. loads 2.5A, .25A/µs, Vout 1%  
µs  
.02  
%/°C  
Efficiency (See curves page 17)  
OUTPUT (Auxiliary Outputs of Triples)  
Set point accuracy  
Load regulation  
0.5  
.2  
.01  
1
.5  
.1  
%
%
%
10A on main, no load auxiliaries  
0 to full load  
over range  
Line regulation  
Ripple  
.25  
.5  
%p-p  
%
µs  
µs  
µs  
0 to 20 mHz  
full load  
20-80% load, Vout within 1%  
low line to high line, Vout 1%  
50-100% load, Vout 1%  
Current Limit (auto.recovery)  
Transient response  
Transient response  
Transient response  
Temp drift  
110-120  
200  
200  
200  
.06  
%/°C  
CONTROL  
Turn on time  
250  
2
1
ms  
ms  
mA  
input power applied, Vout 1%  
Vout within 1%  
sink  
Logic turn on time  
Logic disabled current  
ISOLATION  
Input to output  
Input to case  
Output to case  
Input to output capacity  
4500  
2500  
500  
VDC  
VDC  
VDC  
pF  
consult factory for procedure  
5700  
THERMAL  
Operating temperature  
-40  
+100  
+100  
+110  
°C case  
°C case  
°C/w  
Automatic shut down temperature  
Thermal resistance case to ambient  
+105  
4.2  
single @ Tc=100°C  
triple @ Tc=100°C  
3.3  
7
9
0.5x2.4x3.6  
0.5x2.4x4.6  
°C/w  
oz.  
oz.  
inches  
inches  
WEIGHT  
SIZE  
singles  
triples  
singles  
triples  
(outline drawings see page 16)  
RO Associates, Inc. • Sunnyvale, CA • 408 744-1450 • Fax: 408 744-1521 • email: sales@roassoc.com  
15  
®
RO  
M
ICRO ERTER Outline Drawings  
V
SINGLE OUTPUT  
Note: Filled pins (marked •) are not  
provided in µV300 series models  
TRIPLE OUTPUT  
Note: Filled pins (marked •) are not  
provided in µV300 series models  
RO Associates, Inc. • Sunnyvale, CA • 408 744-1450 • Fax: 408 744-1521 • email: sales@roassoc.com  
16  
Performance Data  
EFFICIENCY CURVES  
2, 3, & 5V Output Models  
12 & 24V Output Models  
85  
80  
75  
70  
90  
85  
80  
75  
5V  
12V  
24V  
3.3V  
2V  
50  
100  
150  
200  
50  
100  
150  
200  
250  
OUTPUT POWER, WATTS  
OUTPUT POWER, WATTS  
Triple Output Models  
Triple Output Models  
85  
85  
80  
75  
70  
80  
75  
70  
5V@ 22A  
5V@ 13A  
5V@5A  
50  
100  
150  
200  
50  
100  
150  
200  
OUTPUT POWER, WATTS  
OUTPUT POWER, WATTS  
Aux. Loads Fixed at ±2A, 5V Load Varied  
5V Load Fixed, Aux. Output Loads  
Varied From 0 to 3A Each  
All Loads Varied  
Note: Typical Efficiency for Tc = 25°C and Nominal Input.  
Input and Output Measured at the Pins.  
RO Associates, Inc. • Sunnyvale, CA • 408 744-1450 • Fax: 408 744-1521 • email: sales@roassoc.com  
17  
®
RO  
M
ICRO ERTER Performance Data (continued)  
V
THERMAL PERFORMANCE  
Thermal Performance-Single Output  
5
100  
75  
50  
25  
0
4
3
2
1
0
25  
50  
75  
100  
AMBIENT TEMPERATURE, °C  
1 - With No Heatsink and No Airflow  
2 - With 2005 Heatsink and No Airflow or, with a 2.2°C/W Heatsink  
3 - With 2005 Heatsink and 200 LFM Airflow or, with a 1.8°C/W Heatsink  
4 - With 2005 Heatsink and 400 LFM Airflow or with a 1.2°C/W Heatsink  
5 - Output Power vs. Case Temperature. No Derating Required for Tc<100°C  
Thermal Performance-Triple Output Models  
5
100  
4
75  
3
2
50  
1
25  
0
0
25  
50  
75  
100  
AMBIENT TEMPERATURE, °C  
1 - With No Heatsink and No Airflow  
2 - With 2006 Heatsink and No Airflow or, with a 2.0°C/W Heatsink  
3 - With 2006 Heatsink and 200 LFM Airflow or, with a 1.5°C/W Heatsink  
4 - With 2006 Heatsink and 400 LFM Airflow or with a 1.0°C/W Heatsink  
5 - Output Power vs. Case Temperature. No Derating Required for Tc<100°C  
RO Associates, Inc. • Sunnyvale, CA • 408 744-1450 • Fax: 408 744-1521 • email: sales@roassoc.com  
18  
OUTPUT RIPPLE & TRANSIENT RESPONSE  
Output Ripple  
Transient Response  
1
1
Vout  
50 µs  
1 µs  
50 mV  
100mV  
1
5V  
2
Iout  
50 µs  
10A  
2
0A  
100 MS/s  
100 MS/s  
MODEL µV48-5. 48V INPUT, 40A LOAD,  
DSO, 400MHZ ANALOG BW, 100 MS/s SAMPLING.  
MODEL µV48-5  
LOAD STEP 8A-32A-8A. CURRENT SLEW RATE 0.5A/µs.  
MINIMUM LOAD - TRIPLES  
Minimum 5V Load vs. Auxiliary Output Power  
Minimum 5V Load vs. Auxiliary Output Power  
µV28 & µV48-Triple Output Models  
µV300 Triple Output Models  
2.0  
2.0  
1.5  
1.0  
1.5  
Tc=100°C  
1.0  
Tc=100°C  
Tc=25°C  
0.5  
0.5  
0.0  
Tc=70°C  
0.0  
30 36  
42  
48  
54  
60  
66  
72  
78  
84  
90  
30 36  
42  
48  
54  
60  
66  
72  
78  
84  
90  
AUXILIARY OUTPUT POWER, WATTS  
AUXILIARY OUTPUT POWER, WATTS  
RO Associates, Inc. • Sunnyvale, CA • 408 744-1450 • Fax: 408 744-1521 • email: sales@roassoc.com  
19  

相关型号:

UV28-T512

DC to DC Converter
ETC

UV28-T512-S

DC to DC Converter
ETC

UV28-T515

DC to DC Converter
ETC

UV28-T515-S

DC to DC Converter
ETC

UV300-12

DC to DC Converter
ETC

UV300-12-S

DC to DC Converter
ETC

UV300-15

DC to DC Converter
ETC

UV300-15-S

DC to DC Converter
ETC

UV300-2

DC to DC Converter
ETC

UV300-2-S

DC to DC Converter
ETC

UV300-24

DC to DC Converter
ETC

UV300-24-S

DC to DC Converter
ETC