INSTALLATION  
INSTRUCTIONS  
V4073A Motorised Mid-Position Valve  
Application  
The V4073A valve has been designed to control the flow of  
water in a small bore domestic central heating system where  
both radiator and hot water cylinder circulation are pumped.  
It is typically suited for systems up to 90,000 Btu/h (26 KW).  
Specifications  
Voltage: 230-240V ~ 50Hz  
Power consumption: 6W  
Lead supplied: 1 metre, 5 core  
Operating temperature range: +5 to +88°C  
(Special models available for chilled water applications)  
Maximum ambient temperature: +52°C  
Pipe fitting sizes:  
22mm & 28mm compression fitting, / " & 1" BSP  
3
4
Dimensions and KV values: See diagrams  
Spares available  
Powerhead  
Part No. 40003916-003  
Part No. 40002737-003  
Part No. 272742A CARD  
Motor  
Ball & ‘O’ Ring Kit  
Installation  
V4073A incorporates a manual  
lever, the lever should normally  
be in ‘AUTO’ position, but can  
be moved to ‘MAN OPEN’  
position for system draindown  
and filling purposes only.  
AUTO  
MAN  
OPEN  
Before fitting the valve, read  
through the plumbing and  
wiring instructions.  
This product MUST be  
installed by a competent  
person. The installation MUST conform to I.E.E.  
Regulations and with The Electricity at Work Regulations.  
A Class ‘A’ switch (having contact separation of at least  
3mm in all poles) must be incorporated in the fixed wiring  
as a means of disconnecting the supply. The system must  
be appropriately fused.  
Flow  
Characteristics  
Plumbing  
The valve MUST NOT be fitted on the return pipework  
under any circumstances. Flow from the boiler must be  
connected to port AB, the radiator circuit to port A and the  
hot water cylinder circuit to port B.  
The valve may be plumbed in at any angle but must not be  
mounted so that the valve head is below the horizontal  
level of the pipework. In the unlikely event of a leak a  
safety hazard could result.  
Do not grip the valve head while making and tightening up  
1
4
plumbing connections. Attach a spanner (32mm or 1 / " AF)  
onto the valve body at each port, whilst tightening up the nuts.  
Tighten compression nuts enough to make a watertight seal.  
TAKE CARE NOT TO OVERTIGHTEN.  
‘Y’ Plan  
Wiring  
The wiring diagram above shows relevant connections to a Honeywell junction box (Part No. 42002116-001). Ensure  
that each numbered, lettered or coloured wire is connected to the correct terminal in the junction box. Make sure all  
connections are good and all terminal screws are firmly tightened.  
Valve wiring configuration is: White = Heating on  
Grey = Hot water off  
Orange = Boiler and pump live  
Blue  
= Neutral  
Green/Yellow = Earth  
Notes:  
a Wiring diagram shows connections to a programmer with separate control of heating and hot water.  
b If single channel time clock is used, connect switched live from time clock to terminal 4 or 6 at junction box, then link  
terminal 4 to terminal 6 with a link wire.  
c If the programmer or time clock have no ‘Hot water OFF’ terminal then the time clock will need to be replaced.  
d If replacing a 6 wire relay model valve with a non relay 5 wire valve, contact Honeywell for advice.  
3 Confirm correct heating functions as follows:  
Checkout procedure  
To ensure the valve is plumbed and wired correctly, carry  
out the following checks after filling the system and  
a Turn cylinder thermostat to minimum or switch off  
at programmer.  
switching on the power.  
b Set room thermostat to maximum and programmer to  
‘CENTRAL HEATING ON’.  
1 a Check manual lever is in ‘AUTO’ position.  
b Check programmer has power.  
c Boiler should fire and pump should run. Feel pipe  
approximately 12" from port A, it should get hot.  
c Check boiler is switched on and its thermostat  
set to maximum.  
4 Confirm valve is functioning at mid position by switching  
‘HEATING ON’ and ‘HOT WATER ON’ at the programmer.  
Set both thermostat to maximum, feel pipes approximately  
12" from both ports A and B. Both pipes should get hot.  
2 Confirm correct hot water functions as follows:  
a Turn room thermostat to minimum setting or switch off  
at programmer.  
Completion  
b Set cylinder thermostat to maximum and programmer to  
Reset both thermostats to temperature required, normally  
60°C for cylinder thermostat and 20°C for room thermostat.  
Return programmer to ‘Auto’ or mode selected by  
householder. Full installation, wiring and operating instructions  
for SUNDIAL products are included in every product pack. For  
special wiring diagrams or applications, contact Honeywell.  
‘HOT WATER ON’.  
c Boiler should fire and pump should run. Feel pipe  
approximately 12" from valve port B, it should get hot.  
Whilst Honeywell takes all practicable steps to design and manufacture its products to comply with the requirements of the Health and Safety at Work Act 1974, all  
products must be properly used and Purchasers are reminded that their obligations under the Act are to ensure that the installation and operation of such products at a  
place of work should be safe and without risk to them.  
Honeywell reserve the right at any time and without notice to change any product or information contained in this publication.  
The wiring diagrams and installation instructions in this publication are provided for guidance purposes when installing recognised standard systems only. Any application of  
this product not shown here, or any deviation from these instructions, is neither recommended nor advised. Any such application or deviation should be referred to  
Honeywell for technical assistance.  
Arlington Business Park  
Bracknell  
Berkshire RG12 1EB  
Telephone: 01344 826000  
Form No. 95C-10820-1  
Rev. 5/97 KT  
Printed In Canada  

相关型号:

V4082

Identification ROM

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EMMICRO

V4082V1ST3B

Identification ROM

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EMMICRO

V4082V1T03E

Identification ROM

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EMMICRO

V4082V2ST3B

Identification ROM

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EMMICRO

V4082V2T03E

Identification ROM

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EMMICRO

V408J232S45

x32 EDO Page Mode DRAM Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

V408J232S50

x32 EDO Page Mode DRAM Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

V408J232S60

x32 EDO Page Mode DRAM Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

V408J32S45

x32 EDO Page Mode DRAM Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

V408J32S50

x32 EDO Page Mode DRAM Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

V408J32S60

x32 EDO Page Mode DRAM Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

V40D100C-M3

Dual High-Voltage Trench MOS Barrier Schottky Rectifier

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY