Nugget 40  
V08 Series  
Integrally Ported 5/2 and 5/3 Spool Valves  
Solenoid Actuated and Pilot Operated  
Ø 4, Ø 6mm or M5  
High flow from 17 mm body width  
Low power solenoids with a range of voltages  
Use valves singly or with Base Systems  
Low profile fixed length manifolds  
Modular manifolds can be DIN rail or surface mounted  
Technical Data  
Ordering Information  
To order, quote model number and voltage code  
from tables overleaf, e.g. V085516A–B213A for a  
Solenoid Pilot Actuated, Spring and Air Return  
model fitted with a 24 V d.c. coil and screwdriver  
operated manual override.  
Medium:  
Compressed air, filtered to 40µm lubricated and non-lubricated  
Operation:  
Spool valve, indirectly actuated  
Mounting:  
Through-holes in valve body or to 35 mm DIN rail using modular  
base system  
Multipole Systems  
For complete Valve Islands see section 5.4.112  
Port Sizes:  
5/2  
M5, Ø 4 mm and Ø 6 mm (with connector blocks)  
Operating Pressure:  
Maximum 10 bar  
See individual details overleaf  
5/2 Twin Supply  
Flow Characteristics:  
Size  
M5  
Ø 4mm 5/2  
Ø 6mm 5/2  
Function ‘C’  
‘b’  
‘A’  
l/min Cv  
Kv  
5/3  
5/2  
1
0,9  
1,4  
0,55  
0,54  
0,42  
4,23  
3,74  
5,7  
256  
226  
344  
296  
0,26 0,22  
0,23 0,2  
0,35 0,3  
All ports blocked mid  
position  
M5  
5/3 APB 1,22 0,32  
4,89  
0,3  
0,26  
5/3  
Centre open exhaust  
mid position  
Ambient Temperature:  
-20˚C to +80˚C Pilot Models  
-20˚C to +50˚C Solenoid Models  
5/3 Centre open  
pressure mid position  
Consult our Technical Service for use below +2˚C  
*
Materials  
Zinc alloy body, glass filled end caps, aluminium spool with  
bonded nitrile rubber seals, and glass filled co-polymer bases.  
2
14  
4
12  
5
1
3
Our policy is one of continued research and development. We therefore reserve the right to amend,  
without notice, the specifications given in this document.  
02/97  
N/** 5.4.105.01  
Nugget 40, V08 Series  
General Information  
5/2 Solenoid Actuated Valves  
Symbol  
Model  
Manual  
Overide  
Solenoid  
Pilot  
Operator  
Solenoid  
Solenoid  
Return  
Operating  
Pressure (bar)  
Pilot  
Pressure (bar)  
Weight  
(kg)  
Spares kit  
4
2
V085516AB21*A  
V085516AB31*A  
V085511AB21*A  
V085511AB31*A  
Screwdriver Bi-stable  
Push Only  
14  
12  
12  
Internal  
Internal  
Spring and Air  
Solenoid  
3 – 10  
2 – 10  
0,155  
0,198  
V10034–K00  
V10034–K00  
5
1
3
4
2
Screwdriver Bi-stable  
Push Only  
14  
5
1
3
*Insert voltage code from table below.  
5/3 Solenoid Actuated Valves  
Symbol  
Model  
Manual  
Overide  
Pilot  
Supply  
Operator  
Mid  
Position  
Return  
Operating  
Pressure (bar)  
Pilot  
Pressure (bar)  
Weight  
(kg)  
Spares kit  
4
4
4
2
2
2
14  
84  
12  
82  
V085611AB21*A  
V085611AB31*A  
Screwdriver Bi-stable  
Push Button  
Internal  
Internal  
Internal  
Solenoid  
Solenoid  
Solenoid  
APB  
Solenoid  
Solenoid  
Solenoid  
-0,9 – 10  
0,158  
V10034–K01  
V10034–K02  
V10034–K03  
5
5
1
1
1
3
3
3
14  
84  
12  
82  
V085711AB21*A  
V085711AB31*A  
Screwdriver Bi-stable  
Push Button  
COE  
COP  
-0,9 – 10  
-0,9 – 10  
0,158  
0,158  
14  
84  
12  
82  
V085811AB21*A  
V085811AB31*A  
Screwdriver Bi-stable  
Push Button  
5
*Insert voltage code from table below.  
Pilot Actuated Valves  
Symbol  
Model  
Manual  
Operator  
Mid-  
Return  
Operating  
Pilot  
Weight  
Spares kit  
Override  
Position  
Pressure (bar)  
Pressure (bar)  
(kg)  
4
2
1,5 + 0,5  
x supply  
14  
12  
V085536AX0130  
V085533AX0020  
V085633AX0020  
V085733A-X0020  
V085833A-X0020  
V085533A-X0060  
Pressure  
-
Spring and Air  
Pressure  
2 - 10  
0,152  
V10034-K00  
V10034-K00  
V10034-K01  
V10034-K02  
V10034-K03  
V10034-K00  
5
1
1
3
4
2
14  
12  
Pressure  
Pressure  
Pressure  
Pressure  
Pilot Priority  
-
1 - 10  
1 - 10  
1 - 10  
1 - 10  
-0,9 - 10  
2 - 10  
0,141  
0,119  
0,119  
0,119  
0,119  
5
3
4
2
Minimum  
2 bar  
APB  
COE  
COP  
Spring and Air  
Spring and Air  
Spring and Air  
Pilot  
14  
12  
12  
12  
5
1
3
4
2
Minimum  
2 bar  
14  
5
1
3
4
2
Minimum  
2 bar  
14  
1
3
5
4
2
Minimum  
2 bar  
14  
12  
5
3
1
APB = All Ports Blocked, COE = Centre Open Exhaust, COP = Centre Open Pressure.  
*Voltage Codes and Spare Coils  
Electrical Details for Solenoid Operators  
Voltage  
Codes  
Power Inrush/Hold  
1,5 W  
Coil Part Number  
V10025-A11  
V10025-A12  
V10025-A13  
V10025-A11  
V10025-A14  
V10025-A16  
V10025-A18  
V10025-A19  
Voltage Tolerances:  
Rating:  
±10%  
6V d.c.  
1
2
3
1
4
6
8
9
100% E.D.  
0,8 mm  
12V d.c.  
1,7 W  
Inlet Orifice:  
24V d.c.  
1,7 W  
Electrical Connection:  
Manual Override:  
DIN 43650 table ‘C’  
12V 50/60Hz  
24V 50/60Hz  
48V 50/60Hz  
110V 50/60Hz  
240V 50/60Hz  
4,1/2,9 VA  
4,1/2,9 VA  
4,1/2,9 VA  
3,5/2,5 VA  
3,5/2,5 VA  
V0855--AB21*A – Screwdriver Bi-stable  
V0855--AB31*A – Push button, spring return  
Protection Class:  
IP 65 (DIN 40050)  
For details of connector plugs and light emitting seals see section 7.7.001.  
Accessories  
Optional Port Connector Blocks  
V085516AQ0404, Ø4 mm  
V085516AQ0404, Ø6 mm  
Blanking Plate  
Optional Tie Rod Kits  
DIN Rail  
Blanking Plug  
V10511–K01  
VO95516AQ1100  
V085516AQ0302–0316  
V10009–C00 1 metre  
Our policy is one of continued research and development. We therefore reserve the right to amend,  
without notice, the specifications given in this document.  
N/** 5.4.105.02  
02/97  
Nugget 40, V08 Series  
V085516A Models  
5/2 Single Solenoid Valve  
V085511A Models  
5/2 Double Solenoid Valve  
156  
12  
109  
65  
65  
12  
Ø2,5  
Ø2,5  
‘14’  
‘12’  
‘14’  
‘12’  
‘5’  
‘1’ ‘3’  
‘5’  
‘1’  
24  
‘3’  
M5 x 0,8  
71  
M5 x 0,8  
24  
71  
142  
12  
101  
65  
65  
12  
M5 x 0,8  
M5 x 0,8  
‘4’  
‘4’  
‘2’  
Ø2,7  
6
‘2’  
Ø2,7  
6
Manual  
Override  
Manual  
Override  
Manual  
Override  
63,25  
16,5  
63,25  
16,5  
V085*11A-B21*A Model  
5/3 Double Solenoid Valve  
171  
Manual Override  
'14'  
M5x0,8  
71  
'12'  
'5' '1' '3'  
24  
157  
12  
65  
M5x0,8  
6
63,25  
16,5  
Our policy is one of continued research and development. We therefore reserve the right to amend,  
without notice, the specifications given in this document.  
02/97  
UK/** 5.4.105.03  
Nugget 40, V08 Series  
V085536A–X0130 Model  
5/2 Single Pilot Valve  
V085533A–X0020 and V085533A–X0060  
5/2 Double Pilot Valves  
23,5  
12  
23,5  
12  
M5x0.8  
M5x0.8  
Ø2,5  
Ø2,5  
14  
12  
14  
12  
5
1
3
5
1
3
M5  
M5  
8,5  
8,5  
24  
60,5  
12  
24  
61,5  
12  
30  
30  
24  
24  
M5  
M5  
4
4
2
2
Ø2,7  
Ø2,7  
6
6
21,8  
22,5  
16,5  
16,5  
V085*33A-X0020 Model  
5/3 Double Pilot Valve  
M5x0.8  
'14'  
'12'  
'5' '1' '3'  
8,5  
M5x0,8  
24  
30  
75  
24  
12  
M5x0,8  
4
2
6
16,5  
36,5  
Our policy is one of continued research and development. We therefore reserve the right to amend,  
without notice, the specifications given in this document.  
N/** 5.4.105.04  
02/97  
Nugget 40 V08 Series  
Modular Manifold for DIN rail or surface mounting  
156  
Manifold Block (A)  
Position indicators  
V085516A–Q01A8  
Single Station Manifold Block  
‘C’  
End Plate Kit (B)  
V085516A–Q02A8  
‘12’  
‘14’  
Consisting of 1 left hand and 1 right hand end cap with  
push-in connectors and DIN rail mounting system  
Size: Ø 8 mm tube  
‘3/5’ ‘1’  
62  
45  
45  
Optional Port Connector Blocks (C)  
Push-in port connector block with integral position  
indicators  
‘B’  
‘3/5’  
‘1’  
V085516A–Q0404  
V085516A–Q0406  
Size: Ø 4 mm tube  
Size: Ø 6 mm tube  
‘4’  
‘4’  
‘4’  
‘2’  
Tie Rod Kits  
‘2’  
‘2’  
V085516A–Q03**  
** = Number of stations in manifold, 02 to 16.  
Pillar screws supplied as standard with Manifold Blocks  
and End Plate kits. Tie Rod Kits are an optional extra.  
‘A’  
‘B’  
‘4’  
‘2’  
‘1’  
‘3/5’  
23  
8
16  
N = Number of stations  
Modular Manifold assemblies for DIN rail or surface mounting  
Modular Manifold Assemblies  
V088AX**–XXXXX  
3/5  
1
Manifold assemblies for 2 to 16 stations, ** = 02 to 16.  
Size: Ø 8 mm tube  
Right hand end  
62  
45  
Dual Pressure Modular Manifold assemblies  
V088AX**–**XXX  
Manifold assemblies for 2 to 16 stations, allows supply of  
two different inlet pressures simultaneously  
Size: Ø 8 mm tube  
** = 1 to 15 to indicate position of Dual Pressure Plug, e.g  
V088AX03–07XX indicates a 10 station base divided into  
groups of 3 and 7.  
Dual Pressure Plug  
V085516A–Q05AA  
To be placed in the inlet gallery  
***  
Left hand end  
23  
16  
15  
N = Number of stations  
*** For 8 mm tube  
Our policy is one of continued research and development. We therefore reserve the right to amend,  
without notice, the specifications given in this document.  
02/97  
UK/** 5.4.105.05  
Nugget 40 V08 Series  
Type  
No. of stations  
A
Fixed Length Manifold  
V10026 – G02  
V10026 – G04  
V10026 – G06  
V10026 – G08  
V10026 – G10  
V10026 – G12  
2
58  
A
G1  
8
/
4
94  
6
130  
166  
202  
238  
5
5
8
10  
12  
Note: Gaskets and valve fixing screws are supplied with  
these manifolds.  
18.5  
18  
21,5  
9
17,5  
Blanking Plugs  
V10511-K01  
For dual pressure supply on Fixed Length Manifold.  
14  
Blanking Plate  
38  
27,5  
V095516A–Q1100  
Blanking Plate for blocking off unwanted stations.  
11  
M2,5  
Accessories  
Connector plugs and light emitting seals see section 7.7.001.  
Warning  
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can  
exceed those listed under ‘Technical Data’.  
Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not  
within published specifications, consult NORGREN.  
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider  
the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to  
equipment in the event of such failure.  
System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be  
adequately provided.  
System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.  
Our policy is one of continued research and development. We therefore reserve the right to amend,  
N/** 5.4.105.06  
02/97  
without notice, the specifications given in this document.  

相关型号:

VOA901CD

Analog IC
ETC

VOA901CN

Analog IC
ETC

VOA901MD

Analog IC
ETC

VOA901MD/883B

Analog IC
ETC

VOAMSFP0000C011

VOA Module with Tap Monitor in SFP Form Factor
OPLINK

VOAMSFP0000L011

VOA Module with Tap Monitor in SFP Form Factor
OPLINK

VOAMSFP0100C011

VOA Module with Tap Monitor in SFP Form Factor
OPLINK

VOAMSFP0100L011

VOA Module with Tap Monitor in SFP Form Factor
OPLINK

VOAMSFP1000C011

VOA Module with Tap Monitor in SFP Form Factor
OPLINK

VOAMSFP1000L011

VOA Module with Tap Monitor in SFP Form Factor
OPLINK

VOAMSFP1100C011

VOA Module with Tap Monitor in SFP Form Factor
OPLINK

VOAMSFP1100L011

VOA Module with Tap Monitor in SFP Form Factor
OPLINK