WM22-DINAV2AXA1 [ETC]

Energy Management Power Analyzer with plug-in Output Modules; 能源管理电源分析仪与插件输出模块
WM22-DINAV2AXA1
型号: WM22-DINAV2AXA1
厂家: ETC    ETC
描述:

Energy Management Power Analyzer with plug-in Output Modules
能源管理电源分析仪与插件输出模块

文件: 总10页 (文件大小:245K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ene rg y Ma na g e m e nt  
Pow e r Ana lyze r w ith p lug -in O utp ut Mod ule s  
Typ e W M2 2 -DIN  
Class 0.5 (current/voltage)  
Three-phase power analyzer  
Back-lighted LCD  
4 x 31/2 DGT instantaneous variables read out  
71/2 DGT energy read-out  
Measurements of system and phase variables:  
W, Wdmd, var, VA, VAdmd, PF (cosϕ), V, A, Hz, THD-A, THD-V  
Measurements of total energies: kWh, kvarh  
Measurements of partial energies: kWh, kvarh  
Energy measurements according to EN61036 and EN61268  
TRMS measurements of distorted wave forms  
(voltages/currents)  
Two basic models: direct connection 20(90)AAC,  
CT 5(10)AAC and VT connection  
Front dimensions: 9 DIN modules  
Maximum value indication of W dmd and VA dmd (only  
5A version); maximum value indication of A (only 90A  
version)  
Self power supply (available for some models only) or  
auxiliary power supply: 24V, 48V, 115V, 230V, 50-60Hz;  
18 to 60VDC, 77 to 143VDC  
Analogue output by means of optional module  
(20mA or 10VDC)  
RS 422/485 Serial port by means of optional module  
Alarm output by means of optional module  
Dual pulse output by means of optional module  
Control of phase asymmetry  
Degree of protection (front): IP 40  
Pro d uct d e scrip tio n  
How to order  
W M2 2 -DIN AV5 3 X X XX  
tion area from 6 to 35 mm2.  
The special design of the  
Model  
Range code  
instruments housing allows System  
Three-phase power analyzer  
with built-in configuration  
key-pad;  
Particularly indicated for the  
analysis of main, secondary  
and energy metering electri-  
cal variables.  
to add at any time the inter-  
face modules, even when  
the instrument is already  
installed.  
Power supply  
Slot A  
Slot B  
Housing for DIN-rail or wall-  
mounting, IP40 (front) pro-  
tection degree.  
Completely sealable housing.  
In case of direct connection  
up to 90A, the measuring  
input terminals are suitable  
for cables with a cross-sec-  
The following modules are Important note:  
available:  
- for all versions: pulses out-  
put;  
The models from AV0 to AV7 can be equipped with any  
type of available modules (slot A and B).  
The models AV8 and AV9 can be equipped only with the  
“O” and “R” type modules.  
- only for the versions with  
auxiliary power supply: The AV8 and AV9 models can measure all the parameters even if  
analogue output, RS485  
port or alarm output.  
the three phase system being connected is missing one phase.  
The Av2 model is suitable only for three-phase unbalanced sys-  
tem without neutral.  
Typ e se le ctio n  
Range Code  
Power supply  
Slot A (retransmission)  
Slot B (retransmission)  
Auxiliary Power Supply:  
For all versions  
X:  
O:  
None  
Only with A-B-C-D-4  
power supply  
AV0: 208VL-L/20(90)AAC [3]  
AV1: 400VL-L/20(90)AAC [1]  
AV3: 660VL-L/20(90)AAC [2]  
AV4: 208VL-L/5(10)AAC [3]  
AV5: 400VL-L/5(10)AAC [1]  
AV6: 100VL-L/5(10)AAC [3]  
AV7: 660VL-L/5(10)AAC [2]  
Self Power Supply:  
AO2900 module  
Dual open collector out-  
put  
A:  
B:  
C:  
D:  
24VAC  
-15+10%, 50-60Hz  
48VAC  
-15+10% , 50-60Hz  
115VAC  
-15+10% , 50-60Hz  
230VAC  
XX:  
A1:  
None  
AO2920 module  
0-20mADC  
Three operating modes:  
analogue output  
AO2921 module  
0-10VDC  
analogue output  
AR2950 module  
RS422/485  
two pulse outputs  
(kWh and kvarh);  
one alarm output  
and one pulse  
output (kWh or kvarh)  
one output which is  
remotely controlled  
by a serial port  
V1:  
S0:  
-15+10% , 50-60Hz  
18 to 60VDC  
77 to 143VDC  
AV2: 220VL-L/20(90)AAC [4]  
AV8: 208VL-L/20(90)AAC [1]  
AV9: 400VL-L/20(90)AAC [1]  
4:  
5:  
AV2, AV8 and AV9 only  
serial port  
X:  
Self Power Supply  
and one pulse  
output (kWh or kvarh)  
System  
400V  
L-L  
(-20+15% , 50-60Hz)  
R:  
AO2910 module.  
3 :  
Three-phase,  
unbalanced load with  
or without neutral  
208V  
L-L  
One relay output + one  
open collector output.  
Operation modes like  
module AO2900.  
(-20+15% , 50-60Hz)  
220V  
L-L  
(-10+15% , 50-60Hz)  
[1] Un: -20+15% [2] Un: -30+15% [3] Un: -20+20% [4] Un: -10 +15%  
Specifications are subject to change without notice WM22-DINDS1003  
1
WM22-DIN  
In p ut sp e cifica tio ns  
Number of inputs  
Current  
Voltage  
Additional errors  
Wave form  
Voltage asymmetry  
Magnetic induction  
HF Electromagnetic fields  
Operation of accessories  
Acc. to EN61036, EN61268  
<1% (3rd harmonic: 10%)  
< 0.5% (referred to Un)  
0 (up to 0.5 mT)  
< 1%  
3
4
Accuracy (display, RS485)  
Ib: 5A, Imax: 10A  
Ib: 20A, Imax:90A  
0
Un: see previous page  
“Range code”  
from 0.003Ib to 0.2Ib:  
±(0.5%RDG +3DGT)  
from 0.2Ib to Imax:  
±(0.5%RDG +1DGT)  
Temperature drift  
Sampling rate  
Display  
200ppm/°C  
Current  
1000 samplings/s @ 50Hz  
Type  
Back-lighted LCD  
Instantan. variables read-out  
Energies  
4x31/  
2
DGT  
Total:1x71/  
Partial: 1x71/  
Voltage  
in the range Un:  
±(0,5% RDG + 1DGT)  
±0.1% RDG (50 to 60 Hz)  
2
DGT  
DGT  
2
Frequency  
Max. and Min. indication  
Measurements  
Max. 1999 (19999999), Min. 0  
Active power  
Current, voltage, power,  
energy, power factor, frequen-  
cy, harmonic distortion (see  
display specs). TRMS  
measurements of distorted  
wave forms.  
(@ 25°C ± 5°C, R.H. 90%) ±(1% RDG +1DGT). PF 1,  
0.1Ib to Imax, in the Un range;  
PF 0.5L, PF 0.8C, 0.2Ib to  
Imax, in the Un range  
Reactive power  
(@ 25°C ± 5°C, R.H. 90%) ±(2% RDG +1DGT). sinϕ 1,  
0.05Ib to Imax, in the Un range;  
sinϕ 0.5L, sinϕ 0.5C,  
0.1Ib to Imax, in the Un range  
Apparent power  
(@ 25°C ± 5°C, R.H. 90%) ±(1% RDG +1DGT). PF 1,  
0.1Ib to Imax, in the Un range  
Energies  
(@ 25°C ± 5°C, R.H. 90%) Class 1 acc. to EN61036  
Class 2 acc. to EN61268  
Coupling type  
Direct  
Crest factor  
Ib 5A  
Ib 20A  
3 (15A max. peak)  
6 (127A max. peak)  
Current overload  
5(10) A, for 10ms  
5(10) A, for 500ms  
5(10) A, permanent  
20(90) A, for 10ms  
20(90) A, permanent  
300 A max, @ 50Hz  
200 A max, @ 50Hz  
10A, @ 50Hz  
2700A max, @ 50Hz  
90A, @ 50Hz  
Ib: 5A, Imax: 10A  
0.1Ib: 500mA,  
Start up corrent: 20mA  
Un: see table “range code”  
Ib: 20A, Imax: 90A  
Voltage overload  
Permanent  
For 1s  
1.2 Un  
2 Un  
0.1Ib: 2A,  
Start up current: 80mA  
Input impedance  
Un: see table “range code”  
400VL-L (AV1-AV5-AV9)  
208VL-L (AV0-AV4-AV8-AV2)  
660VL-L (AV3-AV7)  
100VL-L (AV6)  
5(10) A (AV4-AV5-AV6-AV7)  
> 720KΩ  
> 720KΩ  
> 1.97MΩ  
> 400KΩ  
< 0.3VA  
Harmonic distortion  
±3% f.s. (f.s.: 100%)  
(@ 25°C ± 5°C, R.H. 90%) up to the 7th harmonic;  
Un: see table “range code”  
Ib 5A  
Imin: 500mA;  
Imax: 15Ap;  
Imin: 2A;  
20(90) A (AV0-AV1-AV3-AV8-AV9) < 4VA  
20(90) A (AV2)  
Ib 20A  
< 4VA  
Imax: 127Ap;  
Frequency  
50 to 60 Hz  
In te rfa ce m o d ule sp e cifica tio ns  
Analogue outputs (on request)  
the following ranges:  
Number of outputs  
Range  
1
0 and 20mADC, 0 and 10VDC  
0 to 20 mADC  
Response time  
System variables  
FFT off, filter off  
FFT on, filter on  
variables  
(AO2920 module slot B,  
only for versions with  
auxiliary power supply)  
0 to 10VDC  
(AO2921 module slot B,  
only for versions with  
auxiliary power supply)  
±0.5% F.S.  
300 ppm/ °C  
Programmable within the  
whole range of  
retransmission;  
it allows the retransmission  
of all the values included in  
V, W, VA, var, PF (cosϕ)  
900ms  
1.4s  
THD-V, THD-A  
3s  
Filter off  
Ripple  
1% according to IEC 60688-1,  
EN 60688-1  
Accuracy  
Temperature drift  
Scaling factor  
Load  
20 mADC  
10 VDC  
Insulation  
500 Ω  
10 kΩ  
By means of optocouplers,  
2000 VRMS between output  
and measuring input  
2
Specifications are subject to change without notice WM22-DINDS1003  
WM22-DIN  
Inte rfa ce m o d ule sp e cifica tio ns (co n t.)  
2000 V between output  
and power supply input  
RMS  
According to DIN43864  
By means of optocouplers,  
Insulation  
RS422/RS485 (on request)  
AR2950 module  
2000 V outputs to  
RMS  
Type  
Multidrop  
measuring inputs,  
bidirectional (static and  
and dynamic variables)  
2 or 4 wires, max. distance  
1200m, termination directly  
on the module  
2000 V output to  
supply input.  
Insulation between the two  
outputs: functional  
RMS  
Connections  
Alarm output  
Addresses  
Protocol  
Data (bidirectional)  
Dynamic (reading only)  
255, selectable by key-pad  
MODBUS/JBUS  
Number of outputs  
Alarm type  
1
Up alarm, down alarm  
phase asymmetry, phase  
loss.  
0 to 100% of the electrical  
scale  
0 to 100% of the electrical  
scale  
0 to 255 seconds  
Phase and system variables:  
see table “Display pages”  
All the programming data,  
reset of energy, activation of  
static output.  
Stored energy (EEPROM)  
max. 19.999.999 kWh/kvarh  
1 start bit, 8 data bit,  
no parity, 1 stop bit  
Setpoint adjustment  
Hysteresis  
Static (writing only )  
On-time delay  
Response time  
system variables  
FFT off, filter off  
FFT on, filter on  
variables  
Data format  
V, W, VA, var, PF (cosϕ)  
700ms  
1.2s  
THD-V, THD-A  
3s  
Open collector (transistor NPN)  
VON 1.2 VDC / max. 100 mA  
VOFF 30 VDC max.  
By means of optocouplers,  
Baud-rate  
Insulation  
9600 bit/s  
By means of optocouplers,  
2000 VRMS output  
Filter off  
Output type  
to measuring inputs  
2000 V output to  
RMS  
supply input  
Digital outputs (on request)  
Insulation  
2000 V output to  
measuring input,  
RMS  
AO2900 module  
To be used as alarm, energy  
retransmission, or remote  
static outputs.  
2000 V output to  
RMS  
supply input.  
Insulation between the two  
outputs: functional  
Relay + open collector  
output. Working mode like  
AO2900.  
One static output+one relay  
output, other characteristics  
like AO2900.  
Only relay output, other  
characteristics like AO2900.  
Static type like module  
AO2900;  
Relay type: SPDT,  
AC1, AC15: 1AAC @250VAC  
By means of optocouplers,  
Three working modes are  
selectable:  
two pulse outputs  
(kWh and kvarh);  
one alarm output and  
one pulse output  
(kWh or kvarh)  
one output remotely con-  
trolled by means of the  
serial port and one pulse  
output (kWh or kvarh)  
AO2910 module  
Pulse output  
Alarm output  
Output type  
Pulse outputs  
Number of outputs  
Number of pulses  
2
From 0.01 to 100 pulses  
programmable according  
to the selected CT and VT  
ratios  
Open collector (transistor NPN)  
VON 1.2 VDC / max. 100 mA  
VOFF 30 VDC max.  
Insulation  
2000 V outputs to  
RMS  
measuring inputs,  
2000 V output to  
RMS  
Output type  
supply input.  
Insulation between the two  
outputs: 2000 V  
RMS  
Pulse duration  
220 ms (ON), 220 ms (OFF)  
Specifications are subject to change without notice WM22-DINDS1003  
3
WM22-DIN  
So ftw a re fun ctio ns  
Electrical range  
Filter  
Programmable within the  
whole measuring range.  
Password  
Numeric code of max.  
3 digits  
2 protection levels of the  
programming data  
Password “0”, no protection  
Password from 1 to 1000,  
all data are protected  
Filter operating range  
0 to 99.9% of the input  
electrical scale.  
1 to 16  
Alarm, analogue and serial  
output (fundamental  
variables: V, A, W and their  
derived ones).  
1st level  
2nd level  
Filter coefficient  
Filter action  
System selection  
Three-phase with neutral  
Three-phase without neutral  
Transformer ratio  
CT  
Display  
System variables  
Up to 4 variables per page  
Page 1: W-var-PF (cosϕ)  
Page 2: W dmd - VA dmd - Hz  
Page 3: THD-V  
Page 4: THD-A  
Page 5: kWh total  
Page 6: kvarh total  
Page 7: kWh partial  
Page 8: kvarh partial  
1 to 5000  
VT  
1.0 to 199.9 and 200 to 1999  
Note:  
The CT ratio* VT ratio must  
never exceed the value  
5000. The current  
measuring inputs can  
manage CTs with a  
secondary of 1A and 5A  
(the accuracy always refer  
to 5A)  
Single phase variables  
System variables  
Single phase variables  
Page 9: V  
L-N  
Page 10: A  
20(90) A  
5(10) A  
Page 11a: A MAX  
Page 11b: W dmd MAX VA dmd MAX  
Page 12: W  
Page 13: VA  
Page 14: var  
Scaling factor  
Operating mode  
Compression/expansion of  
the measuring range to be  
connected to the analogue  
output.  
Page 15: PF (cosϕ)  
Sup p ly sp e cifica tio ns  
Self supplied version  
400V  
115VAC  
L-L  
-20% +15%, 50-60Hz  
-15 +10%, 50-60Hz  
48VAC  
208V  
L-L  
-20% +15% , 50-60Hz  
-15 +10%, 50-60Hz  
24VAC  
220V  
L-L  
-10% +15% , 50-60Hz  
-15 +10%, 50-60Hz  
18 to 60VDC  
77 to 143VDC  
Auxiliary power supply  
230VAC  
-15 +10%, 50-60Hz  
Energy consumption  
Pulse voltage (1.2/50µs)  
7VA  
Ge n e ra l Sp e cifica tio ns  
Operating  
0 to +55°C  
8kV (EN61000-4-5)  
temperature  
(R.H. < 90% non-condensing  
40°C)  
Standards  
Safety  
IEC664-1  
Storage  
temperature  
-20 to +60°C  
(R.H. < 90% non-condensing  
40°C)  
Metrology  
Energy measurements:  
EN61036, EN61268.  
DIN43864  
Pulse output  
Installation category  
Insulation  
Cat. III (IEC 664)  
Approvals  
CE  
2000 VRMS between all inputs  
outputs to earth  
/
Connections 5(10) A  
Cable cross-section area  
Screw-type,  
4 mm2  
Dielectric strength  
4000 VRMS for 1 minute  
Connections 20(90) A  
Screw-type,  
Min./Max. cable cross-section area 6 mm2 / 35 mm2  
Min./Max. screws tightening torque 2 Nm / 6 Nm  
Noise rejection  
CMRR  
100 dB, 48 to 62 Hz  
Housing  
Dimensions  
Material  
EMC  
162.5 x 90 x 63 mm  
ABS, NORYL, PC  
self-extinguishing: UL 94 V-0  
Burst  
4kV/level 4 (EN61000-4-4)  
Immunity to irradiated  
electromagnetic fields  
10V/m 26-1000MHz  
(EN61000-4-3)  
15kV (EN61000-4-2)  
according to CISPR 14  
and CISPR 22  
Mounting  
DIN-rail and wall  
Degree of protection  
Front: IP40  
Connections: IP20  
800 g approx.  
(packing included)  
Electrostatic discharges  
Radio frequency emissions  
Weight  
4
Specifications are subject to change without notice WM22-DINDS1003  
WM22-DIN  
Functio n d e scrip tio n  
Input and output scaling capability  
Working examples of the analogue output (Y) versus the input variable (x) - (input/output scaling possibilities).  
Figure A  
Figure B  
The sign of measured quantity  
and output quantity remains  
the same. The output quantity  
is proportional to the mea-  
sured quantity.  
The sign of measured quantity  
and output quantity remains  
the same. With the measured  
quantity being zero, the output  
quantity already has the value  
Y1 = 0.2 Y2.  
Live zero output.  
0
4
50 A  
100 A  
0
0
50 A  
100 A  
12 mA  
20 mA  
10 mA  
20 mA  
Figure C  
The sign of measured quantity  
and output quantity remains  
the same. On the range  
X0...X1, the output quantity is  
zero. The range X1...X2 is deli-  
neated on the entire output  
range Y0=Y1...Y2 and thus  
presented in strongly expan-  
ded form.  
80 V  
0
100 V  
5 mA  
120 V  
10 mA  
Mo d e o f O p e ra tio n  
Waveform of the signals that can be measured  
Figure D  
Figure E  
Figure F  
Sine wave, undistorted  
Fundamental content  
Harmonic content  
Sine wave, indented  
Fundamental content  
Harmonic contents  
Sine wave, distorted  
Fundamental content  
Harmonic content  
100%  
0%  
10...100%  
0...90%  
70...90%  
10...30%  
A
rms  
=
1.1107 | A |  
Frequency spectrum: 3rd to the 16th harmonic  
Additional error: <1% rdg  
Frequency spectrum: 3rd to the 16th harmonic  
Additional error: <0.5% rdg  
Ha rm o nic d isto rtio n a na lysis  
Anaysis principle  
FFT  
THD (AL2), THD (AL3)  
THD %  
Read-out  
System  
Harmonic measurement  
Current  
Voltage  
Up to the 7th harmonic  
Up to the 7th harmonic  
The harmonic distortion  
can be measured in 3-wire  
or 4-wire systems.  
Type of harmonics  
THD (VL1), THD (VL2),  
THD (VL3), THD (AL1)  
Specifications are subject to change without notice WM22-DINDS1003  
5
WM22-DIN  
Disp la y p a g e s  
Variables that can be displayed  
No  
1
1st variable  
2nd variable  
PF sys  
Hz  
3rd variable  
Var sys  
4th variable  
Notes  
W sys  
sys = system  
2
W dmd  
VA dmd  
dmd = demand  
(integration time from 1 to 30 minutes)  
3
V
THD  
V
THD  
V
THD  
THD = tot. harmonic distortion  
THD = tot. harmonic distortion  
total energy  
L1  
L2  
L3  
4
AL1 THD  
kWh  
AL2 THD  
AL3 THD  
5
6
kvarh  
kWh  
total energy  
7
partial energy  
8
kvarh  
partial energy  
9
V
L1  
V
L2  
V
L-3  
VL-L sys  
sys = system  
10  
11a  
11b  
12  
13  
14  
15  
AL1  
W dmd MAX  
AL1 MAX  
WL1  
AL2  
VA dmd MAX  
AL2 MAX  
WL2  
AL3  
Err  
Err = in case of negative power  
Only version 1-5A, dmd = demand  
Only version 90A  
AL3 MAX  
WL3  
W sys  
VA sys  
Var sys  
PF sys  
sys = system  
VAL1  
VAL2  
VAL3  
The system value remains always 0  
if the neutral is not connected  
VarL1  
VarL2  
VarL3  
PFL3  
PFL1  
PFL2  
Used calculation formulas  
Phase variables  
System variables  
Note:  
Instantaneous effective voltage  
Equivalent system voltage  
System reactive power  
System active power  
System apparent power  
System power factor  
i = phase (L1, L2 or L3)  
T = variable (V or I)  
n = harmonic order  
Instantaneous active power  
Consumption recording  
Instantaneous power factor  
(TPF)  
Instantaneous effective current  
Instantaneous apparent power  
Instantaneous reactive power  
Note:  
i = phase (L1, L2 or L3)  
P = active power  
Q = reactive power  
t1, t2 = starting and ending time points of consumption  
recording  
n = time unit  
t = time interval of consumption recording  
(TPF)  
Total harmonic distortion  
n1, n2 = starting and ending discrete time points of consumption  
recording  
List of the of the va ria b les tha t ca n b e connected to the a na log ue a nd a la rm outp ut  
N°  
1
2
3
4
Variable  
V sys  
W sys  
var sys  
VA sys  
PF sys  
Notes  
Variable  
Notes  
sys = system  
sys = system  
sys = system  
sys = system  
sys = system  
6
THD-V  
THD-A  
VA dmd  
W dmd  
ASY  
Max. THD value among the three phases  
Max. THD value among the three phases  
Power demand in the selected  
integration time  
7
8
9
5
10  
Phase asymmetry  
6
Specifications are subject to change without notice WM22-DINDS1003  
WM22-DIN  
Ava ila b le m o d e ls  
Type  
Inputs  
Power supply  
Self power supply  
Self power-supply  
Self power-supply  
230VAC, 50-60Hz  
230VAC, 50-60Hz  
230VAC, 50-60Hz  
115VAC, 50-60Hz  
115VAC, 50-60Hz  
115VAC, 50-60Hz  
48VAC, 50-60Hz  
Ordering code  
AF2100  
WM22-DIN AV9.3.X.  
WM22-DIN AV8.3.X.  
WM22-DIN AV2.3.D.  
WM22-DIN AV1.3.D.  
WM22-DIN AV0.3.D.  
WM22-DIN AV3.3.D.  
WM22-DIN AV1.3.C.  
WM22-DIN AV0.3.C.  
WM22-DIN AV3.3.C.  
WM22-DIN AV1.3.B.  
WM22-DIN AV0.3.B.  
WM22-DIN AV3.3.B.  
WM22-DIN AV1.3.A.  
WM22-DIN AV0.3.A.  
WM22-DIN AV3.3.A.  
WM22-DIN AV5.3.D.  
WM22-DIN AV4.3.D.  
WM22-DIN AV7.3.D.  
WM22-DIN AV5.3.C.  
WM22-DIN AV4.3.C.  
WM22-DIN AV7.3.C.  
WM22-DIN AV5.3.B.  
WM22-DIN AV4.3.B.  
WM22-DIN AV7.3.B.  
WM22-DIN AV5.3.A.  
WM22-DIN AV4.3.A.  
WM22-DIN AV7.3.A.  
WM22-DIN AV6.3.D.  
WM22-DIN AV6.3.C.  
WM22-DIN AV6.3.B.  
WM22-DIN AV6.3.A.  
WM22-DIN AV1.3.4 / [5]  
WM22-DIN AV0.3.4 / [5]  
WM22-DIN AV3.3.4 / [5]  
WM22-DIN AV5.3.4 / [5]  
WM22-DIN AV4.3.4 / [5]  
WM22-DIN AV7.3.4 / [5]  
WM22-DIN AV6.3.4 / [5]  
400V , 20(90)A  
L-L  
208V , 20(90)A  
AF2101  
AF2144  
AF2102  
AF2103  
AF2104  
AF2105  
AF2106  
AF2107  
AF2108  
AF2109  
AF2110  
AF2111  
AF2112  
AF2113  
AF2114  
AF2115  
AF2116  
AF2117  
AF2118  
AF2119  
AF2120  
AF2121  
AF2122  
AF2123  
AF2124  
AF2125  
AF2126  
AF2127  
AF2128  
AF2129  
L-L  
220V , 20(90)A  
L-L  
400V , 20(90)A  
L-L  
208V , 20(90)A  
L-L  
660V , 20(90)A  
L-L  
400V , 20(90)A  
L-L  
208V , 20(90)A  
L-L  
660V , 20(90)A  
L-L  
400V , 20(90)A  
L-L  
208V , 20(90)A  
48VAC, 50-60Hz  
48VAC, 50-60Hz  
24VAC, 50-60Hz  
24VAC, 50-60Hz  
L-L  
660V , 20(90)A  
L-L  
400V , 20(90)A  
L-L  
208V , 20(90)A  
L-L  
660V , 20(90)A  
24VAC, 50-60Hz  
L-L  
400V , 5(10)A  
230VAC, 50-60Hz  
230VAC, 50-60Hz  
230VAC, 50-60Hz  
115VAC, 50-60Hz  
115VAC, 50-60Hz  
115VAC, 50-60Hz  
48VAC, 50-60Hz  
48VAC, 50-60Hz  
48VAC, 50-60Hz  
24VAC, 50-60Hz  
24VAC, 50-60Hz  
L-L  
208V , 5(10)A  
L-L  
660V , 5(10)A  
L-L  
400V , 5(10)A  
L-L  
208V , 5(10)A  
L-L  
660V , 5(10)A  
L-L  
400V , 5(10)A  
L-L  
208V , 5(10)A  
L-L  
660V , 5(10)A  
L-L  
400V , 5(10)A  
L-L  
208V , 5(10)A  
L-L  
660V , 5(10)A  
24VAC, 50-60Hz  
L-L  
100V , 5(10)A  
230VAC, 50-60Hz  
115VAC, 50-60Hz  
48VAC, 50-60Hz  
L-L  
100V , 5(10)A  
L-L  
100V , 5(10)A  
L-L  
100V , 5(10)A  
24VAC, 50-60Hz  
L-L  
400V , 20(90)A  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
AF2130 [AF2137]  
AF2131 [AF2138]  
AF2132 [AF2139]  
AF2133 [AF2140]  
AF2134 [AF2141]  
AF2135 [AF2142]  
AF2136 [AF2143]  
L-L  
208V , 20(90)A  
L-L  
660V , 20(90)A  
L-L  
400V , 5(10)A  
L-L  
208V , 5(10)A  
L-L  
660V , 5(10)A  
L-L  
100V , 5(10)A  
L-L  
Ava ila b le m o d u le s  
Type  
Channels  
Code  
Type  
Channels  
Code  
Open collector output  
0-20mADC analogue output  
Relay + open c. output  
2
1
2
AO2900  
AO2920  
AO2910  
0-10VDC Analogue Output  
RS485 Serial Output  
1
1
AO2921  
AR2950  
Possib le m od ule com b ina tions  
Power supply  
Self p.s.  
Auxiliary p.s.  
Power supply  
Self p.s.  
Auxiliary p.s.  
Basic unit  
Slot A Slot B Slot A Slot B  
Basic unit  
Slot A Slot B Slot A Slot B  
(*)  
(*)  
Analogue output  
RS485 Serial Output  
(*) AV2 only  
Open collector output  
Relay + open c. output  
Specifications are subject to change without notice WM22-DINDS1003  
7
WM22-DIN  
W iring d ia g ra m s  
20(90)A model: three-phase unbalanced load  
Self-power supply  
Fig. 3  
Auxiliary power supply  
Fig. 2  
Auxiliary power supply  
AC power supply  
Fig. 1  
AC power supply  
Direct connection (3-phase system+N)  
Direct connection (3-phase system)  
Direct connection (3-phase system)  
20(90)A model:  
5(10)A model:  
three-phase unbalanced load  
three-phase unbalanced load  
Self-power supply  
Fig. 4  
Auxiliary power supply  
Fig. 5  
Auxiliary power supply  
Fig. 6  
AC power supply  
AC power supply  
Direct connection (3-phase system  
with or without neutral)  
Direct connection (3-phase system + N)  
CT connection (3-phase system+N)  
5(10)A model: three-phase unbalanced load  
Auxiliary power supply  
Fig. 7  
Auxiliary power supply  
AC power supply  
Fig. 9  
Auxiliary power supply  
Fig. 8  
AC power supply  
AC power supply  
CT ARON connection (3-phase system)  
VT and CT ARON connection (3-phase system)  
VT and CT connection (3-phase system + N)  
8
Specifications are subject to change without notice WM22-DINDS1003  
WM22-DIN  
W iring d ia g ra m s (o p tio na l m o d ule s)  
Open collector output  
Fig.10  
Relay + open collector output Fig. 11  
VDC max 30V  
Only open collector outputs: the grounds of the outputs are separated, and therefore its possible to carry out, for the same  
module, two different connections. The load resistance (Rc) must be designed so that the closed contact current is lower than  
100mA; the VDC voltage must be lower than or equal to 30V. VDC: power supply voltage output. Vo+: positive output contact  
(open collector transistor). GND: ground output contact (open collector transistor).  
RS485 Serial output  
Fig. 13  
RS485 Serial output  
Fig. 14  
Analogue output  
Fig. 12  
Current and voltage  
4-wire connection  
2-wire connection  
Fro n t p a ne l d e scrip tio n  
4
3
Keys for:  
- value programming;  
- function selection;  
- displaying the measuring pages.  
2
1
2. Display  
LCD with alphanumeric indications to:  
- display configuration parameters;  
- display all the measured variables.  
3. Removable label  
Label to write the instrument ID number.  
1. Key-pad  
To program configuration parameters and to display variables.  
4. Hidden dip-switch  
Enable/ disable the access to the  
programming procedure.  
S-key to enter programming and confirm selections;  
Specifications are subject to change without notice WM22-DINDS1003  
9
WM22-DIN  
Dim e nsio n s a n d p a ne l cut-o ut  
Te rm in a l b o a rd s  
Analogue output module  
Dual output  
open collector module  
Relay output module +  
open collector output  
RS485  
serial output module  
AO 2920: 0-20 mA  
AO 2921: 0-10 V  
AO 2900  
AO 2910  
AR 2950  
10  
Specifications are subject to change without notice WM22-DINDS1003  

相关型号:

WM22-DINAV2BOA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV2BXA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV2COA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV2CXA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV2DOA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV2DXA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV3AOA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV3AXA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV3BOA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV3BXA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV3COA1

Energy Management Power Analyzer with plug-in Output Modules
ETC

WM22-DINAV3CXA1

Energy Management Power Analyzer with plug-in Output Modules
ETC