XS1N08PA349D [ETC]
NAEHERUNGSSCHALTER 2MM M8 4DRAEHTE ; NAEHERUNGSSCHALTER 2MM M8 4DRAEHTE\n![XS1N08PA349D](http://pdffile.icpdf.com/pdf1/p00014/img/icpdf/XS1M1_66116_icpdf.jpg)
型号: | XS1N08PA349D |
厂家: | ![]() |
描述: | NAEHERUNGSSCHALTER 2MM M8 4DRAEHTE
|
文件: | 总40页 (文件大小:2756K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Inductive proximity sensors
Cylindrical type, Ø 4 mm plain or M5 x 0.5 threaded
Metal case (stainless steel), short
d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
a
Lengths (mm) :
a = Overall
b = Threaded or plain section
a = 29
b = 29
a = 41
b = 24
Nominal sensing distance (Sn)
0.8 mm
0.8 mm
References
3-wire a
PNP
NPN
NO
NO
XS1-L04PA311
XS1-L04NA311
0.025
XS1-L04PA311S
XS1-L04NA311S
0.010
Weight (kg)
Characteristics
3
Connection
Pre-cabled, 3 x 0.11 mm2, length 2 m (1)
Connector (types 1 to 8) (2)
Depending on connector
(see pages 3/58 and 3/59)
Degree of protection
IP 67
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity
- 25…+ 70 °C
LED, side mounted
a 5…30 V
0…100 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 10 mA
5000 Hz
3-wire a, NO output
BN/1
BN/1
+
+
PNP
BK/4 (NO)
BK/2 (NC)
NPN
BK/4 (NO)
BK/2 (NC)
–
–
BU/3
BU/3
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.030 kg
0.080 kg
Example : sensor XS1-L04PA311 with 5 m cable becomes XS1-L04PA311L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
3/20
Te
a = 29
a = 45
a = 41
b = 24
a = 33
b = 27
c = 3
a = 42
b = 31
c = 3
a = 45
b = 21
c = 3
b = 24
b = 24
0.8 mm
0.8 mm
XS1-N05PA311
XS1-N05NA311
0.030
XS1-N05PA311S
XS1-N05NA311S
0.015
3
Pre-cabled, 3 x 0.11 mm2, length 2 m (1)
Connector (types 1 to 8) (2)
IP 67
Depending on connector (see pages 3/58 and 3/59)
- 25…+ 70 °C
LED, side mounted
a 5…30 V
0…100 mA with overload and short-circuit protection
≤ 2 V
≤ 10 mA
5000 Hz
3/21
Te
Inductive proximity sensors
Cylindrical type, Ø 6.5 mm plain
Metal case (brass or stainless steel), short
d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Plain section
a = 33 (XS1-L06iC410 : a = 50)
b = 30 (XS1-L06iC410 : b = 47)
a = 42
b = 34
c = For non flush mounting sensors
Stainless steel case
1.5 mm
Brass case
Increased range model
2.5 mm
Stainless steel case
1.5 mm
Brass case
Increased range model
2.5 mm
Nominal sensing distance (Sn)
References
3-wire a
PNP
NPN
PNP
NPN
NO
XS1-L06PA340
XS1-L06NA340
XS1-L06PC410
XS1-L06NC410
0.025
XS1-L06PA349
XS1-L06PA340S
XS1-L06PA349S
NO
XS1-L06NA349
XS1-L06NA340S
XS1-L06NA349S
4-wire a
(complementary
outputs)
NO + NC
NO + NC
–
–
–
–
–
–
3
Weight (kg)
0.025
0.010
0.010
Characteristics
Pre-cabled,
Connection
3 x 0.11 mm2 or 4 x 0.08 mm2, L = 2 m (1)
Connector (types 1 to 8) (2)
Depending on connector
(see pages 3/58 and 3/59)
Degree of protection
IP 67
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity
- 25…+ 70 °C
- 25…+ 50 °C
- 25…+ 70 °C
- 25…+ 50 °C
LED, annular
LED, 4 viewing ports at 90°
a 10…38 V (c 24 V rectified and filtered)
0…200 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 2.6 V
≤ 10 mA
350 Hz
≤ 2 V
≤ 2.6 V
≤ 10 mA
350 Hz
≤ 10 mA
5000 Hz
≤ 10 mA
5000 Hz
3-wire a, NO output
XS1/XS2-L06ii340/340S/340D/349/349S/349D
4-wire a, NO + NC output
XS1-L06ii410
BN/1
PNP
BN/1
NPN
BN/1
NPN
BN/1
PNP
+
–
+
–
+
+
BK/4 (NO)
BK/2 (NC)
BK/4 (NO)
WH/2 (NC)
BK/4 (NO)
BK/2 (NC)
BK/4 (NO)
WH/2 (NC)
–
–
BU/3
BU/3
BU/3
BU/3
Note : for XSi-L06i i34iS sensors, NO or NC output on terminal 4
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
Weight increase
0.030 kg
10 m
L2
0.080 kg
Example : sensor XS1-L06PA340 with 5 m cable becomes XS1-L06PA340L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
3/22
Te
Non flush mountable in metal
a = 45
a = 45
a = 33
a = 33
a = 42
a = 42
a = 45
a = 45
b = 24
b = 24
b = 27
b = 27
b = 31
b = 31
b = 21
b = 21
c = 3
c = 3
c = 3
c = 3
c = 3
c = 3
Stainless steel case
1.5 mm
Brass case
Increased range model
2.5 mm
Stainless steel case
Stainless steel case
Stainless steel case
2.5 mm
2.5 mm
2.5 mm
XS1-L06PA340D
XS1-L06PA349D
XS2-L06PA340
XS2-L06PA340S
XS2-L06PA340D
XS1-L06NA340D
XS1-L06NA349D
XS2-L06NA340
XS2-L06NA340S
XS2-L06NA340D
–
–
–
–
–
–
–
–
–
–
3
0.015
0.015
0.025
0.010
0.015
Connector
Connector
Pre-cabled, 3 x 0.11 or
Connector
(types 1 to 8) (2)
Connector
(types 9, 10, 11/12, 15, 16) (2)
(types 9, 10, 11/12, 15, 16) (2) (types 9, 10, 11, 12, 15, 16) (2) 4 x 0.08 mm2, L = 2 m (1)
Depending on connector (see pages 3/58 and 3/59)
IP 67
Depending on connector (see pages 3/58 and 3/59)
- 25…+ 70 °C
- 25…+ 50 °C
- 25…+ 70 °C
LED, annular
LED, 4 viewing ports at 90°
LED, 4 viewing ports at 90°
a 10…38 V (c 24 V rectified and filtered)
0…200 mA with overload and short-circuit protection
≤ 2 V
≤ 2.6 V
≤ 10 mA
350 Hz
≤ 2 V
≤ 10 mA
5000 Hz
≤ 10 mA
5000 Hz
3/23
Te
Inductive proximity sensors
Cylindrical type, M8 x 1 threaded
Metal case (brass), short
d.c. supply
References, characteristics, dimensions, schemes
Accessories :
page 3/59
Flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 33
b = 26
a = 42
b = 26
c = For non flush mounting sensors
Increased range model
2.5 mm
Increased range model
2.5 mm
Nominal sensing distance (Sn)
1.5 mm
1.5 mm
References
3-wire a
PNP
NPN
NO
NO
XS1-N08PA340
XS1-N08NA340
0.035
XS1-N08PA349
XS1-N08NA349
0.035
XS1-N08PA340S
XS1-N08NA340S
0.015
XS1-N08PA349S
XS1-N08NA349S
0.015
Weight (kg)
Characteristics
3
Pre-cabled,
Connection
3 x 0.11 mm2 or 4 x 0.08 mm2, L = 2 m (1)
Connector (types 1 to 8) (2)
Depending on connector
(see pages 3/58 and 3/59)
Degree of protection
IP 67
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity
- 25…+ 70 °C
- 25…+ 50 °C
- 25…+ 70 °C
- 25…+ 50 °C
LED, annular
LED, 4 viewing ports at 90°
a 10…38 V (c 24 V rectified and filtered)
0…200 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 2.6 V
≤ 10 mA
350 Hz
≤ 2 V
≤ 2.6 V
≤ 10 mA
350 Hz
≤ 10 mA
5000 Hz
≤ 10 mA
5000 Hz
3-wire a, NO output
XS1/XS2-N08ii340/340S/340D/349/349S/349D
BN/1
BN/1
+
+
PNP
BK/4 (NO)
BK/2 (NC)
NPN
BK/4 (NO)
BK/2 (NC)
–
–
BU/3
BU/3
Note : for XSi-N08ii34iS sensors, NO output on terminal 4
(1) Sensors pre-cabled with other cable lengths :
Length of cable
Suffix to be added to references stated above for 2 m pre-cabled sensors
Weight increase
5 m
10 m
L1
L2
0.030 kg
0.080 kg
Example : sensor XS1-N08PA340 with 5 m cable becomes XS1-N08PA340L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
3/24
Te
Non flush mountable in metal
a = 45
b = 24
a = 33
b = 22
c = 4
a = 42
b = 23
c = 4
a = 45
b = 20
c = 4
Increased range model
2.5 mm
1.5 mm
2.5 mm
2.5 mm
2.5 mm
XS1-N08PA340D
XS1-N08NA340D
0.020
XS1-N08PA349D
XS1-N08NA349D
0.020
XS2-N08PA340
XS2-N08NA340
0.035
XS2-N08PA340S
XS2-N08NA340S
0.015
XS2-N08PA340D
XS2-N08NA340D
0.020
3
Connector
Connector
Pre-cabled, 3 x 0.11 or
Connector
(types 1 to 8) (2)
Connector
(types 9, 10, 11/12, 15, 16) (2)
(types 9, 10, 11/12, 15, 16) (2) (types 9, 10, 11/12, 15, 16) (2) 4 x 0.08 mm2, L = 2 m (1)
Depending on connector (see pages 3/58 and 3/59)
IP 67
Depending on connector (see pages 3/58 and 3/59)
- 25…+ 70 °C
- 25…+ 50 °C
- 25…+ 70 °C
LED, annular
LED, 4 viewing ports at 90°
LED, 4 viewing ports at 90°
a 10…38 V (c 24 V rectified and filtered)
0…200 mA with overload and short-circuit protection
≤ 2 V
≤ 2.6 V
≤ 10 mA
350 Hz
≤ 2 V
≤ 10 mA
5000 Hz
≤ 10 mA
800 Hz
3/25
Te
Inductive proximity sensors
Cylindrical type, M8 x 1 threaded
Metal case (stainless steel), form A
d.c. supply
Accessories:
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 50
b = 40
a = 61
b = 40
Nominal sensing distance (Sn)
1.5 mm
1.5 mm
References
3-wire a
PNP
NPN
NO
NC
NO
XS1-M08PA370
–
XS1-M08PA370D
–
XS1-M08PB370
–
XS1-M08PB370D
–
XS1-M08NA370
–
XS1-M08NA370D
–
2-wire a (non polarised)
Supply to : Terminals 3-4 NO
4-wire a (complementary
–
–
–
–
3
outputs)
PNP
NO + NC
–
XS1-M08PC410
–
XS1-M08PC410D
Weight (kg)
0.035
0.035
0.025
0.025
Characteristics
Connection
Pre-cabled, 3 x 0.11 mm2, length 2 m (1)
Connector (types 9, 10, 11/12, 15, 16) (2)
Depending on connector
Degree of protection
IP 67
(see pages 3/58 and 3/59)
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity
- 25…+ 80 °C
LED annular
LED, 4 viewing ports at 90°
a 10…58 V
a 10…38 V
a 10…58 V
a 10…38 V
0…200 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 10 mA
5000 Hz
3-wire a, NO or NC output
XS1-M08ii370/370D
2-wire a non polarised, NO output
XS1-M08Di210/210D/210LD
4-wire a, NO + NC output
XS1-M08ii410/410D
BN/1
BN/1
PNP
BN/1
BN/1
+
+
+
–
+/
–/
–
+
–
BN/1
BN/3
BN/1
+/
–/
–
BK/4 (NO)
WH/2 (NC)
BK/4 (NO) NPN
BK/2 (NC)
PNP
BU/3
NPN
BU/3
BK/4 (NO)
BK/2 (NC)
–
BK/4 (NO)
WH/2 (NC)
NC
NO
BU/2
BU/4
–
+
+
BU/3
BU/3
(1) Sensors pre-cabled with other cable lengths:
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.030 kg
0.080 kg
Example: sensor XS1-M08PA370 with 5 m cable becomes XS1-M08PA370L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
3/26
Te
a = 50
b = 40
a = 61
b = 40
a = 50
b = 40
Length of cable: 0.8 m
1.5 mm
1.5 mm
1.5 mm
–
–
–
–
–
–
–
–
–
XS1-M08DA210
XS1-M08DA210D
XS1-M08DA210LD
3
–
–
–
0.035
0.025
0.040
Pre-cabled, 2 x 0.11 mm2,
Connector
Connector (types 9, 10, 15, 16)
length 2 m (1)
(types 9, 10, 15, 16) (2)
or splitter boxes (2)
IP 67
Dpg. on connector (see pages 3/58 and 3/59)
- 25…+ 80 °C
LED, annular
a 10…58 V
LED, 4 viewing ports at 90°
LED, annular
1,5…100 mA with overload and short-circuit protection
≤ 5.2 V
–
800 Hz
3/27
Te
Inductive proximity sensors
Cylindrical type, M8 x 1 threaded
Metal case (stainless steel), form A
a.c. or d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 50
b = 40
c = For non flush mounting sensors
Nominal sensing distance (Sn)
1.5 mm
References
2-wire c or a
NO
NC
XS1-M08MA230
XS1-M08MB230
0.035
Weight (kg)
Characteristics
3
Connection
Pre-cabled, 2 x 0.11 mm2, length 2 m (1)
Degree of protection
Operating temperature
Output state indication
IP 67
- 25…+ 80 °C
LED, annular
c or a 20…264 V
5…100 mA (2)
≤ 5.5 V
Voltage limits (including ripple)
Switching capacity
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
–
(c) 25 Hz or (a) 650 Hz
2-wire c or a, NO or NC output
BN/2
BU/3
For connector version sensors
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.030 kg
0.080 kg
Example : sensor XS1-M08MA230 with 5 m cable becomes XS1-M08MA230L1
(2) These sensors do not incorporate overload or short-circuit protection and therefore, it is recommended that a 0.8 A “quick-blow” fuse be connected in series
with the load.
3/28
Te
Non flush mountable in metal
a = 50
a = 45
a = 33
b = 27
c = 3
a = 42
b = 31
c = 3
a = 45
b = 21
c = 3
b = 36
b = 24
c = 4
2.5 mm
XS2-M08MA230
XS2-M08MB230
0.035
3
Pre-cabled, 2 x 0.11 mm2, length 2 m (1)
IP 67
- 25…+ 80 °C
LED, annular
c or a 20…264 V
5…100 mA (2)
≤ 5.5 V
–
(c) 25 Hz or (a) 400 Hz
3/29
Te
Inductive proximity sensors
Cylindrical type, M12 x 1 threaded
Metal case (brass), short
d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 33
b = 26
a = 45
b = 25
c = For non flush mounting sensors
Increased range model
4 mm
Increased range model
4 mm
Nominal sensing distance (Sn)
2 mm
2 mm
References
3-wire a
PNP
NPN
NO
XS1-N12PA340
XS1-N12NA340
XS1-N12PC410
0.070
XS1-N12PA349
XS1-N12PA340D
XS1-N12NA340D
XS1-N12PC410D
0.020
XS1-N12PA349D
NO
XS1-N12NA349
XS1-N12NA349D
4-wire a (complementary
outputs)
PNP
NO + NC
–
–
Weight (kg)
0.070
0.020
3
Characteristics
Connection
Pre-cabled, 3 x 0.34 mm2 or 4 x 0.22 mm2,
Connector
Connector (types 9,
length 2 m (1)
(types 9, 10, 15, 16) (2) 10, 11, 12, 15, 16) (2)
Depending on connector
Degree of protection
IP 67
(see pages 3/58 and 3/59)
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity
- 25…+ 70 °C
- 25…+ 50 °C
- 25…+ 70 °C
- 25…+ 50 °C
LED, annular
LED, 4 viewing ports at 90°
a 10…38 V (c 24 V rectified and filtered)
0…200 mA with overload and short-circuit protection
Voltage drop, closed state
≤ 2 V
≤ 2.6 V
≤ 2 V
≤ 2.6 V
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 10 mA
5000 Hz
300 Hz
5000 Hz
300 Hz
3-wire a, NO output
XS1/XS2-N12ii340/340D/349/349D
4-wire a, NO + NC output
XS1-N12ii410/410D
BN/1
BN/1
NPN
BN/1
BN/1
NPN
+
+
–
+
+
–
BK/4 (NO)
WH/2 (NC)
PNP
BK/4 (NO)
BK/2 (NC)
PNP
BK/4 (NO)
BK/2 (NC)
–
BK/4 (NO)
WH/2 (NC)
–
BU/3
BU/3
BU/3
BU/3
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.090 kg
0.240 kg
Example : sensor XS1-N12PA340 with 5 m cable becomes XS1-N12PA340L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
3/30
Te
Non flush mountable in metal
a = 33
b = 21
c = 5
a = 45
b = 20
c = 5
4 mm
4 mm
XS2-N12PA340
XS2-N12PA340D
XS2-N12NA340
XS2-N12NA340D
–
–
0.070
0.020
3
Pre-cabled, 3 x 0.34 mm2 or 4 x 0.22 mm2, length 2 m (1)
Connector (types 9, 10, 15, 16) (2)
IP 67
Depending on connector (see pages 3/58 and 3/59)
- 25…+ 70 °C
LED, annular
LED, 4 viewing ports at 90°
a 10…38 V (c 24 V rectified and filtered)
0…200 mA with overload and short-circuit protection
≤ 2 V
≤ 10 mA
5000 Hz
3/31
Te
Inductive proximity sensors
Cylindrical type, M12 x 1 threaded
Metal case (brass), form A
d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 50
b = 42
a = 61
b = 40
c = For non flush mounting sensors
Nominal sensing distance (Sn)
2 mm
2 mm
2 mm
2 mm
References
3-wire a
PNP
NPN
NO
XS1-M12PA370
XS1-M12NA370
–
–
XS1-M12PA370D
XS1-M12NA370D
–
–
NO
–
–
4-wire a
PNP/NPN
NO/NC
XS1-M12KP340
XS1-M12KP340D
universal model
programmable
3
Weight (kg)
0.075
0.075
0.025
0.025
Characteristics
Connection
Pre-cabled, 3 x 0.34 mm2, length 2 m (1)
Degree of protection
IP 68
Depending on connector
(see pages 3/58 and 3/59)
Operating temperature
- 25…+ 80 °C
Output state indication
Voltage limits (including ripple)
Switching capacity
LED, annular
LED, 4 viewing ports at 90°
a 10…58 V (3) a 10…38 V (4)
0…200 mA with overload and short-circuit protection
a 10…58 V (3)
a 10…38 V (4)
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 2.6 V
≤ 2 V
≤ 2.6 V
≤ 10 mA
5000 Hz
3-wire a, NO output
XS1/XS2-M12ii370/370D
4-wire a programmable, NO or NC output
XS1/XS2-M12KP340/340D
BN/1 (NO), BU/3 (NC)
BN/1 (NO), BU/3 (NC)
BN/1
BN/1
+
–
+
+
+
WH/2
NPN
NPN
PNP
BK/4
PNP
BK/4 (NO)
BK/2 (NC)
BK/4 (NO)
BK/2 (NC)
WH/2
BK/4
–
–
–
BU/3
BU/3
BU/3 (NO), BN/1 (NC)
BU/3 (NO), BN/1 (NC)
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
Weight increase
0.090 kg
10 m
L2
0.240 kg
Example : sensor XS1-M12PA370 with 5 m cable becomes XS1-M12PA370L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
(3) Can be supplied with rectified c 24 V.
(4) c 24 V rectified and filtered.
3/32
Te
Non flush mountable in metal
a = 50
b = 37
c = 5
a = 61
b = 35
c = 5
4 mm
4 mm
4 mm
4 mm
XS2-M12PA370
XS2-M12NA370
–
–
XS2-M12PA370D
XS2-M12NA370D
–
–
–
XS2-M12KP340
XS2-M12KP340D
3
0.075
0.075
0.025
0.075
Pre-cabled, 3 x 0.34 mm2, length 2 m (1)
Connector (types 9, 10, 15, 16) (2)
IP 68
Depending on connector
(see pages 3/58 and 3/59)
- 25…+ 80 °C
LED, annular
LED, 4 viewing ports at 90°
a 10…58 V (3)
a 10…58 V (3)
a 10…38 V (4)
a 10…38 V (4)
≤ 2.6 V
0…200 mA with overload and short-circuit protection
≤ 2 V
≤ 2.6 V
≤ 2 V
≤ 10 mA
5000 Hz
3/33
Te
Inductive proximity sensors
Cylindrical type, M12 x 1 threaded
Metal case (brass), form A
d.c. supply (continued)
References, characteristics, dimensions, schemes
Accessories :
page 3/59
Flush mountable in metal
b
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 50
b = 42
a = 61
b = 40
Nominal sensing distance (Sn)
References
2 mm
2 mm
2-wire a (non polarised)
Supply to :
Terminals 3-4
NO
NC
XS1-M12DA210
XS1-M12DB210
0.075
XS1-M12DA210D
XS1-M12DB210D
0.025
Terminals 1-2
Weight (kg)
Characteristics
3
Connection
Pre-cabled, 2 x 0.34 mm2, length 2 m (1)
Connector (types 9, 10, 15, 16) (2)
Degree of protection
IP 68
Depending on connector
(see pages 3/58 and 3/59)
Operating temperature
- 25…+ 80 °C
LED, annular
a 10…58 V
Output state indication
Voltage limits (including ripple)
Switching capacity
LED, 4 viewing ports at 90°
1.5…100 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 5.2 V
–
800 Hz
2-wire a non polarised, NO or NC output
XS1-M12DA210/DA210D
XS1-M12DB210/210D/210LD
BN/3
BN/1
BN/1
+/
–/
–
+/
–/
–
NO
NC
BU/4
+
BU/2
+
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.090 kg
0.240 kg
Example : sensor XS1-M12DA210 with 5 m cable becomes XS1-M12DA210L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
3/34
Te
Inductive proximity sensors
Cylindrical type, M12 x 1 threaded
Metal case (brass), form A
a.c. or d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
Non flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 50
b = 42
a = 50
b = 37
c = 5
c = For non flush mounting sensors
AC/DC
2 mm
AC/DC
Nominal sensing distance (Sn)
4 mm
References
2-wire c or a
NO
NC
NO
NC
XS1-M12MA230
XS1-M12MB230
XS1-M12MA250
XS1-M12MB250
0.075
XS2-M12MA230
XS2-M12MB230
XS2-M12MA250
XS2-M12MB250
0.075
2-wire c or a
(protected against
short-circuits)
3
Weight (kg)
Characteristics
Connection
Pre-cabled, 2 x 0.34 mm2, L = 2 m (1)
Degree of protection
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity
IP 68
- 25…+ 80 °C
LED, annular
c or a 20…264 V
5…200 mA (3)
≤ 5.5 V
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
–
(c) 25 Hz or (a) 350 Hz
2-wire c or a, NO or NC output
XS1/XS2-M12ii230/250
BN/2
BU/3
For connector version sensors
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.075 kg
0.200 kg
Example : sensor XS1-M12MA230 with 5 m cable becomes XS1-M12MA230L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
(3) For the sensors not incorporating overload or short-circuit protection, it is recommended that a 0.8 A “quick-blow” fuse be connected in series with the load.
3/35
Te
Inductive proximity sensors
Cylindrical type, M18 x 1 threaded
Metal case (brass), short
d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 33.5
b = 26
a = 45
b = 26
c = For non flush mounting sensors
Increased range model
10 mm
Increased range model
10 mm
Nominal sensing distance (Sn)
5 mm
5 mm
References
3-wire a
PNP
NPN
PNP
NPN
NO
XS1-N18PA340
XS1-N18NA340
XS1-N18PC410
XS1-N18NC410
0.100
XS1-N18PA349
XS1-N18PA340D
XS1-N18NA340D
XS1-N18PC410D
XS1-N18NC410D
0.040
XS1-N18PA349D
NO
XS1-N18NA349
XS1-N18NA349D
4-wire a
(complementary
outputs)
NO + NC
NO + NC
–
–
–
–
3
Weight (kg)
0.100
0.040
Characteristics
Pre-cabled, 3 x 0.34 mm2 or 4 x 0.34 mm2,
Connector
Connector (types 9,
Connection
length 2 m (1)
(types 9, 10, 15, 16) (2) 10, 11, 12, 15, 16) (2)
Depending on connector
Degree of protection
IP 67
(see pages 3/58 and 3/59)
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity
- 25…+ 70 °C
- 25…+ 50 °C
- 25…+ 70 °C
- 25…+ 50 °C
LED, annular
LED, 4 viewing ports at 90°
a 10…38 V (c 24 V rectified and filtered)
0…200 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 2.6 V
≤ 2 V
≤ 2.6 V
≤ 10 mA
2000 Hz
60 Hz
2000 Hz
60 Hz
3-wire a, NO output
XS1/XS2-N18ii340/340D/349/349D
4-wire a, NO + NC output
XS1/XS2-N18ii410/410D
BN/1
BN/1
BN/1
BN/1
NPN
+
+
+
+
–
BK/4 (NO)
WH/2 (NC)
PNP
BU/3
BK/4 (NO)
BK/2 (NC)
PNP
BU/3
NPN
BK/4 (NO)
BK/2 (NC)
BK/4 (NO)
WH/2 (NC)
–
–
–
BU/3
BU/3
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.120 kg
0.320 kg
Example : sensor XS1-N18PA340 with 5 m cable becomes XS1-N18PA340L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
3/36
Te
Non flush mountable in metal
a = 33.5
b = 18
c = 8
a = 45
b = 18
c = 8
8 mm
8 mm
XS2-N18PA340
XS2-N18PA340D
XS2-N18NA340
XS2-N18NA340D
–
–
–
–
3
0.100
0.030
Pre-cabled, 3 x 0.34 mm2 or 4 x 0.34 mm2, length 2 m (1)
Connector (types 9, 10, 15, 16) (2)
IP 67
Depending on connector (see pages 3/58 and 3/59)
- 25…+ 70 °C
LED, annular
LED, 4 viewing ports at 90°
a 10…38 V (c 24 V rectified and filtered)
0…200 mA with overload and short-circuit protection
≤ 2 V
≤ 10 mA
2000 Hz
3/37
Te
Inductive proximity sensors
Cylindrical type, M18 x 1 threaded
Metal case (brass), form A
d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
a
Lengths (mm) :
a = Overall
a = 60
a = 70
b = Threaded section
b = 51.5
b = 51.5
Nominal sensing distance (Sn)
5 mm
5 mm
5 mm
5 mm
References
3-wire a
PNP
NPN
NO
XS1-M18PA370
XS1-M18NA370
–
–
XS1-M18PA370D
XS1-M18NA370D
–
–
NO
–
–
4-wire a
PNP/NPN
NO/NC
XS1-M18KP340
XS1-M18KP340D
universal model
programmable
3
Weight (kg)
0.120
0.120
0.060
0.060
Characteristics
Connection
Pre-cabled, 3 x 0.34 mm2, length 2 m (1)
Connector (types 9, 10, 15, 16) (2)
Depending on connector
Degree of protection
Operating temperature
IP 68
(see pages 3/58 and 3/59)
- 25…+ 80 °C
LED, annular
Output state indication
LED, 4 viewing ports at 90°
Voltage limits (including ripple)
Switching capacity
a 10…58 V (3)
a 10…38 V (4)
a 10…58 V (3)
a 10…38 V (4)
0…200 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 2.6 V
≤ 2 V
≤ 2.6 V
≤ 10 mA
2000 Hz
3-wire a, NO output
XS1-M18ii370/370D
4-wire a programmable, NO or NC output
XS1-M18KP340/340D
BN/1 (NO), BU/3 (NC)
BN/1 (NO), BU/3 (NC)
BN/1
BN/1
+
+
–
+
+
–
WH/2
PNP
PNP
BK/4 (NO)
BK/2 (NC)
NPN
NPN
BK/4 (NO)
BK/2 (NC)
WH/2
BK/4
BK/4
–
–
BU/3
BU/3
BU/3 (NO), BN/1 (NC)
BU/3 (NO), BN/1 (NC)
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.120 kg
0.320 kg
Example : sensor XS1-M18PA370 with 5 m cable becomes XS1-M18PA370L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
(3) Can be supplied with rectified c 24 V.
(4) c 24 V rectified and filtered.
3/38
Te
Inductive proximity sensors
Cylindrical type, M18 x 1 threaded
Metal case (brass), form A
d.c. supply (continued)
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Non flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 60
b = 43.5
c = 8
c = For non flush mounting sensors
Nominal sensing distance (Sn)
8 mm
8 mm
References
3-wire a
PNP
NPN
NO
NO
XS2-M18PA370
XS2-M18NA370
–
–
–
4-wire a
universal model
PNP/NPN NO/NC
programmable
XS2-M18KP340
3
Weight (kg)
0.120
0.120
Characteristics
Connection
Pre-cabled, 3 x 0.34 mm2, length 2 m (1)
Degree of protection
Operating temperature
IP 68
- 25…+ 80 °C
LED, annular
a 10…58 V (2)
Output state indication
Voltage limits (including ripple)
Switching capacity
a 10…38 V (3)
0…200 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 2.6 V
≤ 10 mA
2000 Hz
3-wire a, NO output
XS2-M18ii370
4-wire a programmable, NO or NC output
XS2-M18KP340
BN/1 (NO), BU/3 (NC)
BN/1 (NO), BU/3 (NC)
BN/1
NPN
BN/1
+
+
+
–
+
–
WH/2
PNP
PNP
BK/4 (NO)
BK/2 (NC)
NPN
BK/4 (NO)
BK/2 (NC)
–
WH/2
BK/4
BK/4
–
BU/3
BU/3
BU/3 (NO), BN/1 (NC)
BU/3 (NO), BN/1 (NC)
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.120 kg
0.320 kg
Example : sensor XS2-M18PA370 with 5 m cable becomes XS2-M18PA370L1
(2) Can be supplied with rectified c 24 V.
(3) c 24 V rectified and filtered.
3/39
Te
Inductive proximity sensors
Cylindrical type, M18 x 1 threaded
Metal case (brass), form A
d.c. supply (continued)
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 50
b = 42
a = 60
b = 42
Nominal sensing distance (Sn)
References
5 mm
5 mm
2-wire a (non polarised)
Supply to :
Terminals 3-4
NO
NC
XS1-M18DA210
XS1-M18DB210
0.120
XS1-M18DA210D
Terminals 1-2
–
Weight (kg)
0.060
Characteristics
3
Connection
Pre-cabled, 2 x 0.5 mm2, length 2 m (1)
Connector (types 9, 10, 15, 16) (2)
Depending. on connector
Degree of protection
IP 68
(see pages 3/58 and 3/59)
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity
- 25…+ 80 °C
LED, annular
a 10…58 V
LED, 4 viewing ports at 90°
1.5…100 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 5.2 V
–
350 Hz
2-wire a, non polarised, NO or NC output
XS1-M18DA210/DA210D
XS1-M18DB210
BN/1
+/
–/
–
BN/3
BN/1
+/
–/
–
NC
NO
BU/2
BU/4
+
+
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
Weight increase
0.120 kg
10 m
L2
0.320 kg
Example : sensor XS1-M18DA210 with 5 m cable becomes XS1-M18DA210L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
3/40
Te
Inductive proximity sensors
Cylindrical type, M18 x 1 threaded
Metal case (brass), form A
a.c. or d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
a
Lengths (mm) :
a = Overall
a = 60
b = Threaded section
b = 51.5
AC/DC
5 mm
Nominal sensing distance (Sn)
References
2-wire c or a
NO
NC
NO
NC
XS1-M18MA230
XS1-M18MB230
XS1-M18MA250
XS1-M18MB250
0.120
2-wire c or a
(protected against
short-circuits)
3
Weight (kg)
Characteristics
Connection
Pre-cabled, 2 x 0.5 mm2, length 2 m (1)
Degree of protection
Operating temperature
IP 68
- 25…+ 80 °C
Output state
indication
non protected model
protected model
LED, annular
1 red LED (output state), 1 green LED (supply and short-circuit indication)
Voltage limits (including ripple)
Switching capacity
c or a 20…264 V
(c) 5…300 mA or (a) 5…200 mA (2)
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 5.5 V
–
(c) 25 Hz or (a) 200 Hz
2-wire c or a, NO or NC output
XS1-M18Mi230/250
BN/2
BU/3
For connector version sensors
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.120 kg
0.320 kg
Example : sensor XS1-M18MA230 with 5 m cable becomes XS1-M18MA230L1
(2) For the sensors not incorporating overload or short-circuit protection, it is recommended that a 0.8 A “quick-blow” fuse be connected in series with the load.
3/41
Te
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass), short
d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 40.5
b = 32
a = 50
b = 30
c = For non flush mounting sensors
Increased range model
20 mm
Increased range model
20 mm
Nominal sensing distance (Sn)
10 mm
10 mm
References
3-wire a
PNP
NPN
NO
NO
XS1-N30PA340
XS1-N30NA340
0.160
XS1-N30PA349
XS1-N30NA349
0.160
XS1-N30PA340D
XS1-N30NA340D
0.100
XS1-N30PA349D
XS1-N30NA349D
0.100
Weight (kg)
Characteristics
3
Connector
Connector (types 9,
Connection
Pre-cabled, 3 or 4 x 0.34 mm2, length 2 m (1)
(types 9, 10, 15, 16) (2) 10, 11/12, 15, 16) (2)
Depending on connector
Degree of protection
IP 67
(see pages 3/58 and 3/59)
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity
- 25…+ 70 °C
- 25…+ 50 °C
- 25…+ 70 °C
- 25…+ 50 °C
LED, annular
LED, 4 viewing ports at 90°
a 10…38 V (c 24 V rectified and filtered)
0…200 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 2.6 V
≤ 2 V
≤ 2.6 V
≤ 10 mA
1000 Hz
15 Hz
1000 Hz
15 Hz
3-wire a, NO output
XS1/XS2-N30i340/340D/349/349D
BN/1
BN/1
+
+
PNP
BU/3
BK/4 (NO)
BK/2 (NC)
NPN
BK/4 (NO)
BK/2 (NC)
–
–
BU/3
(1) Sensors pre-cabled with other cable lengths :
Length of cable
Suffix to be added to references stated above for 2 m pre-cabled sensors
Weight increase
5 m
10 m
L1
L2
0.120 kg
0.320 kg
Example : sensor XS1-N30PA340 with 5 m cable becomes XS1-N30PA340L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
3/42
Te
Non flush mountable in metal
a = 40.5
b = 19
c = 13
a = 50
b = 19
c = 13
15 mm
15 mm
XS2-N30PA340
XS2-N30NA340
0.160
XS2-N30PA340D
XS2-N30NA340D
0.100
3
Pre-cabled, 3 or 4 x 0.34 mm2, length 2 m (1)
Connector (types 9, 10, 15, 16) (2)
IP 67
Depending on connector (see pages 3/58 and 3/59)
- 25…+ 70 °C
LED, annular
LED, 4 viewing ports at 90°
a 10…38 V (c 24 V rectified and filtered)
0…200 mA with overload and short-circuit protection
≤ 2 V
≤ 10 mA
1000 Hz
3/43
Te
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass), form A
d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
a
Lengths (mm) :
a = Overall
a = 60
a = 70
b = Threaded section
b = 51.5
b = 51.5
Nominal sensing distance (Sn)
10 mm
10 mm
10 mm
10 mm
References
3-wire a
PNP
NPN
NO
XS1-M30PA370
XS1-M30NA370
–
–
XS1-M30PA370D
XS1-M30NA370D
–
–
NO
–
–
4-wire a
PNP/NPN
NO/NC
XS1-M30KP340
XS1-M30KP340D
universal model
programmable
3
Weight (kg)
0.205
0.205
0.145
0.145
Characteristics
Connection
Pre-cabled, 3 x 0.34 mm2, length 2 m (1)
Connector (types 9, 10, 15, 16) (2)
Depending on connector
Degree of protection
IP 68
(see pages 3/58 and 3/59)
Operating temperature
- 25…+ 80 °C
LED, annular
Output state indication
Voltage limits (including ripple)
Switching capacity
LED, 4 viewing ports at 90°
a 10…58 V (3)
a 10…38 V (4)
a 10…58 V (3)
a 10…38 V (4)
0…200 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 2.6 V
≤ 2 V
≤ 2.6 V
≤ 10 mA
1000 Hz
3-wire a, NO output
XS1-M30ii370/370D
4-wire a programmable, NO or NC output
XS1-M30KP340/340D
BN/1 (NO), BU/3 (NC)
BN/1 (NO), BU/3 (NC)
BN/1
BN/1
NPN
+
–
+
+
–
+
WH/2
PNP
PNP
BK/4 (NO)
BK/2 (NC)
NPN
BK/4 (NO)
BK/2 (NC)
WH/2
BK/4
BK/4
–
–
BU/3
BU/3
BU/3 (NO), BN/1 (NC)
BU/3 (NO), BN/1 (NC)
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.120 kg
0.320 kg
Example : sensor XS1-M30PA370 with 5 m cable becomes XS1-M30PA370L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
(3) Can be supplied with rectified c 24 V.
(4) c 24 V rectified and filtered.
3/44
Te
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass), form A
d.c. supply (continued)
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Non flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 60
b = 38.5
c = 13
a = 70
b = 38.5
c = 13
c = For non flush mounting sensors
Nominal sensing distance (Sn)
15 mm
15 mm
15 mm
15 mm
References
3-wire a
PNP
NO
XS2-M30PA370
XS2-M30NA370
–
–
XS2-M30PA370D
XS2-M30NA370D
–
–
NPN
NO
–
–
4-wire a
PNP/NPN
NO/NC
XS2-M30KP340
XS2-M30KP340D
universal model programmable
3
Weight (kg)
0.205
0.205
0.145
0.145
Characteristics
Connection
Pre-cabled, 3 x 0.34 mm2, length 2 m (1)
Connector (types 9, 10, 15, 16) (2)
Depending on connector
Degree of protection
IP 68
(see pages 3/58 and 3/59)
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity
- 25…+ 80 °C
LED, annular
LED, 4 viewing ports at 90°
a 10…58 V (3)
a 10…38 V (4)
a 10…58 V (3)
a 10…38 V (4)
0…200 mA with overload and short-circuit protection
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 2 V
≤ 2.6 V
≤ 2 V
≤ 2.6 V
≤ 10 mA
1000 Hz
3-wire a, NO output
XS2-M30ii370/370D
4-wire a programmable, NO or NC output
XS2-M30KP340/340D
BN/1 (NO), BU/3 (NC)
BN/1 (NO), BU/3 (NC)
BN/1
BN/1
NPN
+
+
+
–
+
–
WH/2
PNP
PNP
BK/4 (NO)
BK/2 (NC)
NPN
BK/4 (NO)
BK/2 (NC)
WH/2
BK/4
BK/4
–
–
BU/3
BU/3
BU/3 (NO), BN/1 (NC)
BU/3 (NO), BN/1 (NC)
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.120 kg
0.320 kg
Example : sensor XS2-M30PA370 with 5 m cable becomes XS2-M30PA370L1
(2) The type numbers refer to suitable female connectors and extension cables, see pages 3/58 and 3/59.
(3) Can be supplied with rectified c 24 V.
(4) c 24 V rectified and filtered.
3/45
Te
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass), form A
a.c. or d.c. supply
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable in metal
b
a
Lengths (mm) :
a = Overall
a = 60
b = Threaded section
b = 51.5
AC/DC
10 mm
Nominal sensing distance (Sn)
References
2-wire c or a
NO
XS1-M30MA230
XS1-M30MB230
XS1-M30MA250
XS1-M30MB250
0.205
NC
NO
NC
2-wire c or a
(protected against
short-circuits)
3
Weight (kg)
Characteristics
Connection
Pre-cabled, 2 x 0.5 mm2, length 2 m (1)
Degree of protection
Operating temperature
IP 68
- 25…+ 80 °C
Output state
indication
non protected model
protected model
LED, annular
1 red LED (output state), 1 green LED (supply and short-circuit indication)
Voltage limits (including ripple)
Switching capacity
c or a 20…264 V
(c) 5…300 mA or (a) 5…200 mA (2)
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 5.5 V
–
(c) 25 Hz or (a) 100 Hz
2-wire c or a, NO or NC output
XS1-M30Mi230/250
BN/2
BU/3
For connector version sensors
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.120 kg
0.320 kg
Example : sensor XS1-M30MA230 with 5 m cable becomes XS1-M30MA230L1
(2) For the sensors not incorporating overload or short-circuit protection, it is recommended that a 0.8 A “quick-blow” fuse be connected in series with the load.
3/46
Te
Inductive proximity sensors
Cylindrical type, M30 x 1.5 threaded
Metal case (brass), form A
a.c. or d.c. supply (continued)
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Non flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 60
b = 38.5
c = 13
c = For non flush mounting sensors
AC/DC
Nominal sensing distance (Sn)
15 mm
References
2-wire c or a
NO
NC
NO
NC
XS2-M30MA230
XS2-M30MB230
XS2-M30MA250
XS2-M30MB250
0.205
2-wire c or a
(protected against
short-circuits)
3
Weight (kg)
Characteristics
Connection
Pre-cabled, 2 x 0.5 mm2, L = 2 m (1)
Degree of protection
Operating temperature
IP 68
- 25…+ 80 °C
Output state
indication
non protected model
protected model
LED, annular
1 red LED (output state)
1 green LED (supply and short-circuit indication)
Voltage limits (including ripple)
Switching capacity
c or a 20…264 V
(c) 5…300 mA or (a) 5…200 mA (2)
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 5.5 V
–
(c) 25 Hz or (a) 75 Hz
2-wire c or a, NO or NC output
XS2-M30ii2i0
BN/2
BU/3
For connector version sensors
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L1
L2
Weight increase
0.120 kg
0.320 kg
Example : sensor XS2-M30MA230 with 5 m cable becomes XS2-M30MA230L1
(2) For the sensors not incorporating overload or short-circuit protection, it is recommended that a 0.8 A “quick-blow” fuse be connected in series with the load.
3/47
Te
Inductive proximity sensors
Compact block (12 x 26 x 40 mm), plastic, type XSG
a.c. or d.c. supply
References, characteristics, schemes
Accessories :
page 3/59
Flush mountable in metal
Non flush mountable in metal
Nominal sensing distance (Sn)
2 mm
4 mm
References
4-wire a
(complementary
outputs)
PNP
NPN
NO + NC
NO + NC
XSG-H027330
XSG-J027330
0.180
XSG-H047330
XSG-J047330
0.180
Weight (kg)
Characteristics
3
Connection
Pre-cabled, length 2 m (1) 4 x 0.34 mm2
Degree of protection
Operating temperature
Output state indication
IP 65
- 25…+ 70 °C
LED, at rear
a 10…58 V
0…200 mA (2)
≤ 1.8 V
Voltage limits (including ripple)
Switching capacity
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 10 mA
1000 Hz
800 Hz
4-wire a
NO + NC output
+
–
+
BN
BN
NPN
BK (NO)
PNP
WH (NC)
BK (NO)
WH (NC)
BU
BU
–
(1) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above for 2 m pre-cabled sensors
L05
L10
Weight increase
0.120 kg
0.320 kg
Example : sensor XSG-H027330 with 5 m cable becomes XSG-H027330L05
(2) With overload and short-circuit protection.
3/48
Te
Inductive proximity sensors
Plug-in compact block (41 x 50 x 76 mm), plastic, type XSB
a.c. or d.c. supply
References, characteristics, schemes
Accessories :
page 3/59
Non flush mountable in metal
DC
AC
Nominal sensing distance (Sn)
25 mm
25 mm
References
2-wire a
2-wire c
NO
NO
NC
XSB-C25710
–
–
XSB-A25911
XSB-A25921
0.190
–
Weight (kg)
0.190
3
Characteristics
Connection
Screw terminals, capacity : 2 x 1.5 mm2
Degree of protection
IP 67
Operating temperature
Output state indication
Voltage limits (including ripple)
Switching capacity (1)
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
- 25… + 70 °C
–
LED
a 12…58 V
1.5…80 mA
≤ 7 V
c 93…264 V
20…150 mA
≤ 9.5 V
–
–
250 Hz
40 Hz
2-wire a
NO output
2-wire c
NO output
NC output
1
+
–
1
3
4
2
4
(1) For XSB-A (c) sensors, not incorporating overload or short-circuit protection, it is recommended that a 0.63 A “quick-blow” fuse be connected in series
with the load.
3/49
Te
Inductive proximity sensors
Plug-in block form C (41 x 40 x 117 mm), plastic, type XS7
5 position turret head
d.c. supply
Accessories :
page 3/59
References, characteristics, schemes
Flush mountable in metal
Increased range model
Nominal sensing distance (Sn)
15 mm
20 mm
15 mm
References
4-wire a
(complementary
outputs)
PNP
NPN
NO + NC
NO + NC
XS7-C40PC440H29
XS7-C40PC449H29
–
XS7-C40NC440H29
XS7-C40NC449H29
–
2-wire a
(non polarised)
NO
–
–
XS7-C40DA210H29
XS7-C40DP210H29
0.220
NO or NC
programmable
–
–
3
Weight (kg)
0.220
0.220
Characteristics
Connection
Screw terminals, capacity : 2 or 4 x 1.5 mm2
Degree of protection
IP 67
Operating temperature
- 25…+ 70 °C
Output LED + Supply LED
a 10…58 V
Supply/output state indication
Voltage limits (including ripple)
Switching capacity
Output LED
0…200 mA
1.5…100 mA
(with overload and short-circuit protection)
Voltage drop, closed state
≤ 2 V
≤ 5.2 V
–
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 10 mA
1000 Hz
150 Hz
2-wire a (non polarised)
NO or NC output
4-wire a
NO + NC output
depending on position of link
+
+
–
1
1
5
+/
–/
NO
–
4 (NO)
2 (NC)
PNP
NPN
4 (NO)
2 (NC)
6
+
3
3
–
NO
NC
NC
3/50
Te
Inductive proximity sensors
Plug-in block form C (41 x 40 x 117 mm), plastic, type XS8
5 position turret head
d.c. supply
Accessories :
page 3/59
References, characteristics, schemes
Non flush mountable in metal
Increased range model
Nominal sensing distance (Sn)
20 mm
40 mm
20 mm
References
4-wire a
(complementary
outputs)
PNP
NPN
NO + NC
NO + NC
XS8-C40PC440H29
XS8-C40NC440H29
–
XS8-C40PC449H29
XS8-C40NC449H29
–
–
–
2-wire a
NO or NC
XS8-C40DP210H29
(non polarised)
programmable
3
Weight (kg)
0.220
0.220
0.220
Characteristics
Connection
Screw terminals, capacity : 2 or 4 x 1.5 mm2
Degree of protection
IP 67
Operating temperature
- 25…+ 70 °C
Output LED + Supply LED
a 10…58 V
Supply/output state indication
Voltage limits (including ripple)
Switching capacity
Output LED
0…200 mA
1.5…100 mA
(with overload and short-circuit protection)
Voltage drop, closed state
≤ 2 V
≤ 5.2 V
–
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 10 mA
1000 Hz
500 Hz
100 Hz
2-wire a (non polarised)
NO or NC output
4-wire a
NO + NC output
depending on position of link
+
–
+
–
1
1
5
+/
–/
NO
–
4 (NO)
PNP
NPN
4 (NO)
2 (NC)
2 (NC)
6
+
3
3
NO
NC
NC
3/51
Te
Inductive proximity sensors
Plug-in block form C (41 x 40 x 117 mm), plastic, types XS7 and XS8
5 position turret head
a.c. or d.c. supply
Accessories :
pages 3/59
References, characteristics, schemes
Flush mountable in metal
Non flush mountable in metal
AC
AC/DC
AC
AC/DC
Nominal sensing distance (Sn)
15 mm
20 mm
References
2-wire c
NO/NC
programmable
XS7-C40FP260H29
–
XS8-C40FP260H29
–
2-wire c or a
universal model
NO/NC
programmable
–
XS7-C40MP230H29
–
XS8-C40MP230H29
Weight (kg)
0.220
0.220
0.220
0.220
3
Characteristics
Connection
Screw terminals, capacity : 2 x 1.5 mm2
Degree of protection
Operating temperature
IP 67
- 25…+ 70 °C
Output LED
Supply/output state indication
Voltage limits
c 20…264 V
c or a 20…264 V
c 5…300 mA or
5…500 mA (1)(2 A inrush) a 5…200 mA (1)
c 20…264 V
c or a 20…264 V
c 5…300 mA or
Switching capacity
5…500 mA (1)(2 A inrush) a 5…200 mA (1)
Voltage drop, open state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 5.5 V
–
25 Hz
c 25 Hz, a 50 Hz
25 Hz
c 25 Hz, a 50 Hz
2-wire c programmable
NO or NC output depending on position of link
2-wire c or a programmable
NO or NC output depending on position of link
NO
NC
NO
NC
5
6
5
6
(1) These sensors do not incorporate overload or short-circuit protection and therefore, it is recommended that a 0.8 A “quick-blow” fuse be connected in
series with the load.
3/52
Te
Inductive proximity sensors
Plug-in block form D (40 x 80 x 100 mm), plastic, type XSD
d.c. supply and a.c./d.c. supply
References, characteristics, schemes
Accessories :
page 3/59
Non flush mountable in metal
DC
AC/DC
Nominal sensing distance (Sn)
30…60 mm (1)
References
4-wire a
PNP
NO + NC
XSD-H607339
–
(complementary outputs)
2-wire c or a
universal model
NO or NC
programmable
–
XSD-M600539
Weight (kg)
0.480
0.480
3
Characteristics
Connection
Screw terminals, capacity : 2 x 1.5 mm2
Degree of protection
Operating temperature
IP 67
- 25…+ 70 °C
Output LED
a 10…58 V
0…200 mA
Supply/output state indication
Voltage limits (including ripple)
Switching capacity
Output LED + Supply LED + Short-circuit LED
c or a 20...264 V
(a) 5...100 mA or (c) 5...500 mA
(with overload and short-circuit protection)
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
≤ 1.8 V
≤ 10 mA
20 Hz
≤ 6 V
–
10 Hz
4-wire a
2-wire c or a programmable
NO output
+
+
–
NO + NC output
NC output
1
1
5
5
4 (NO)
PNP
NPN
2 (NC)
4 (NO)
2 (NC)
6
6
8
3
3
7
8
7
–
(1) XSD-i60 sensors incorporate a sensing distance adjustment potentiometer. This enables adjustment to suit the following requirements :
- limiting the effects of surrounding objects (by decreasing the sensing distance),
- increasing the sensing distance up to 48 mm, using a standard mild steel target. Settings above 48 mm are not recommended.
3/53
Te
Inductive proximity sensors
Analogue output models
Cylindrical type, M12 x 1 threaded, metal or plastic case
Pre-cabled with 2 m cable
3
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable
in metal
Non flush mountable in metal
b
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 50
b = 42
a = 50
b = 42
a = 50
b = 42
Metal case
0.2…2 mm
Plastic case
0.4…4 mm
Plastic case
0.4…4 mm
Nominal sensing distance (Sn)
References
3-wire a
Output
Output
0…10 mA (1)
4…14 mA (2)
–
–
XS4-P12AB110
4…20 mA (2)
0…16 mA (1)
XS1-M12AB120
XS4-P12AB120
–
Weight (kg)
0.075
0.065
0.065
3
Characteristics
Connection
Pre-cabled, 3 x 0.34 mm2, length 2 m
IP 67
Degree of protection
Ambient air temperature
Voltage limits (including ripple)
Operation : - 25…+ 70 °C
a 15…38 V
≤ 10 %
a 15…38 V
a 15…58 V
Output current drift
θ ambient : - 25…+ 70 °C
Current consumption, no-load
4 mA
(1) Output current range for “3-wire” connection, see schemes below.
(2) Output current range for “2-wire” connection, see schemes below.
Wiring schemes
2-wire connection
3-wire connection
BN/1
BN/1
+
+
Output voltage
mA
mA
BK/4
Is
BK/4
Output current
R
R
U=R.Is
–
BU/3
BU/3
–
Is
Output current
Value of R (R = load impedance)
Output current
Value of R (R = load impedance)
24 V
4…14 mA
4…20 mA
4…14 mA
≤ 640 Ω
≤ 450 Ω
≤ 2350 Ω
24 V
0…10 mA
0…16 mA
0…10 mA
≤ 1800 Ω
≤ 1125 Ω
≤ 4200 Ω
48 V
48 V
Ensure a minimum of 15 V between the + (1) and - (3) terminals of the sensor
Ensure a minimum of 5 V between the + and sensor output (terminal 4)
Other versions
“Original equipment” range Ø 12 mm sensors with analogue output (XSP-Hiii62).
Please consult your Regional customer centre.
3/54
Te
Inductive proximity sensors
Analogue output models
Cylindrical type, M18 x 1 threaded, metal or plastic case
Pre-cabled with 2 m cable
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable
in metal
Non flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 50
b = 42
a = 40.6
b = 26
a = 40.6
b = 26
c = For non flush mounting sensors
c = 0
c = 8
c = 8
Metal case
Plastic case
Plastic case
Nominal sensing distance (Sn)
0.5…5 mm
0.8…8 mm
0.8…8 mm
References
3-wire a
Output
Output
0…10 mA (1)
4…14 mA (2)
–
–
XS4-P18AB110
4…20 mA (2)
0…16 mA (1)
XS1-M18AB120
XS4-P18AB120
–
Weight (kg)
0.120
0.080
0.080
3
Characteristics
Connection
Pre-cabled, 3 x 0.34 mm2, length 2 m
Degree of protection
IP 67
Ambient air temperature
Voltage limits (including ripple)
Operation : - 25…+ 70 °C
a 15…38 V
≤ 10 %
a 15…58 V
Output current drift
θ ambient : - 25…+ 70 °C
Current consumption, no-load
4 mA
1) Output current range for “3-wire” connection, see schemes below.
(2) Output current range for “2-wire” connection, see schemes below.
Wiring schemes
2-wire connection
3-wire connection
BN/1
BN/1
+
+
Output voltage
mA
mA
BK/4
Is
BK/4
Output current
R
R
U=R.Is
–
BU/3
BU/3
–
Is
Output current
Value of R (R = load impedance)
Output current
Value of R (R = load impedance)
24 V
4…14 mA
4…20 mA
4…14 mA
≤ 640 Ω
≤ 450 Ω
≤ 2350 Ω
24 V
0…10 mA
0…16 mA
0…10 mA
≤ 1800 Ω
≤ 1125 Ω
≤ 4200 Ω
48 V
48 V
Ensure a minimum of 15 V between the + (1) and - (3) terminals of the sensor
Ensure a minimum of 5 V between the + and sensor output (terminal 4)
Other versions
“Original equipment” range Ø 18 mm sensors with analogue output (XSP-Hiii62).
Please consult your Regional customer centre.
3/55
Te
Inductive proximity sensors
Analogue output models
Cylindrical type, M30 x 1.5 threaded, metal or plastic case
Pre-cabled with 2 m cable
Accessories :
page 3/59
References, characteristics, dimensions, schemes
Flush mountable
in metal
Non flush mountable in metal
b
c
a
Lengths (mm) :
a = Overall
b = Threaded section
a = 50
b = 42
a = 52.6
b = 32
a = 52.6
b = 32
c = For non flush mounting sensors
c = 0
c = 13
c = 13
Metal case
Plastic case
Plastic case
Nominal sensing distance (Sn)
1…10 mm
1.5…15 mm
1.5…15 mm
References
3-wire a
Output
Output
0…10 mA (1)
4…14 mA (2)
–
–
XS4-P30AB110
4…20 mA (2)
0…16 mA (1)
XS1-M30AB120
XS4-P30AB120
–
Weight (kg)
0.200
0.100
0.100
3
Characteristics
Connection
Pre-cabled, 3 x 0.34 mm2, length 2 m
Degree of protection
IP 67
Ambient air temperature
Voltage limits (including ripple)
Operation : - 25…+ 70 °C
a 15…38 V
≤ 10 %
a 15…58 V
Output current drift
θ ambient : - 25…+ 70 °C
Current consumption, no-load
4 mA
(1) Output current range for “3-wire” connection, see schemes below.
(2) Output current range for “2-wire” connection, see schemes below.
Wiring schemes
2-wire connection
3-wire connection
BN/1
BN/1
+
+
Output voltage
mA
mA
BK/4
Is
BK/4
Output current
R
R
U=R.Is
–
BU/3
BU/3
–
Is
Output current
Value of R (R = load impedance)
Output current
Value of R (R = load impedance)
24 V
4…14 mA
4…20 mA
4…14 mA
≤ 640 Ω
≤ 450 Ω
≤ 2350 Ω
24 V
0…10 mA
0…16 mA
0…10 mA
≤ 1800 Ω
≤ 1125 Ω
≤ 4200 Ω
48 V
48 V
Ensure a minimum of 15 V between the + (1) and - (3) terminals of the sensor
Ensure a minimum of 5 V between the + and sensor output (terminal 4)
3/56
Te
Inductive proximity sensors
For specific applications : rotation monitoring
Cylindrical type, metal case
References, characteristics, dimensions, schemes
Accessories :
page 3/59
Flush mountable in metal
b
a
Lengths (mm) :
a = Overall
a = 81
b = Threaded section
b = 57
Ø = M30 x 1.5
Nominal sensing distance (Sn)
10 mm
10 mm
10 mm
References
Impulses/minute
6…150
3-wire a PNP
XSA-V11373
–
–
120…3000
Impulses/minute
6…150
XSA-V12373
–
–
2-wire c
–
XSA-V11151
XSA-V12151
0.300
XSA-V11161
XSA-V12161
0.300
120…3000
–
3
Weight (kg)
0.300
Characteristics
Connection (2)
Pre-cabled, 3 x 0.34 mm2,
length 2 m
Pre-cabled, 2 x 0.5 mm2, length 2 m
Degree of protection
IP 67
Operating temperature (1)
Output state indication
Voltage limits (including ripple)
Switching capacity
- 25…+ 70 °C
LED
a 10…58 V
c 93…132 V
c 187…264 V
0…200 mA with overload
& short-circuit protection
20…350 mA
(2 A inrush)
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
3-wire a
≤ 1.8 V
≤ 4.5 V
≤ 10 mA
–
6000 impulses/minute (for XSA-V11iii) ; 48,000 impulses/minute (for XSA-V12 iii)
2-wire c
+
BN/1
BN
PNP
BK/4
BU
BU/3
–
(1) Other operating temperature ranges : - 40…+ 70 °C (To order, add suffix TF to above refs.), - 25…+ 85 °C (To order, add suffix TT to above refs.).
(2) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Suffix to be added to references stated above
L05
L10
Weight increase
0.120 kg
0.320 kg
Example : sensor XSA-V11373 with 5 m cable becomes XSA-V11373L05
Other versions
Sensors without initial “run-up” delay, or with reduced “run-up” delay on energisation of 3 seconds.
SX2-DV units for monitoring overspeed or underspeed conditions, in the range 0 to 6000 impulses/
minute.
Please consult your Regional customer centre.
3/57
Te
Inductive proximity sensors
Female connectors
References, characteristics, dimensions, schemes
Connector type No
Number of pins
9
10
11
12
4
4
4
4
Female connector version
References
M12 straight
M12 elbowed
M12 elbowed
M12 elbowed
PVR cable connection,
Ø 5 mm
L = 2 m
L = 5 m
L = 10 m
XZ-CP1141L2
XZ-CP1141L5
XZ-CP1141L10
XZ-CP1241L2
XZ-CP1241L5
XZ-CP1241L10
XZ-CP1340L2
XZ-CP1340L5
XZ-CP1340L10
XZ-CP1440L2
XZ-CP1440L5
XZ-CP1440L10
3
Weight (kg)
0.090 (L = 2 m), 0.190 (L = 5 m), 0.370 (L = 10 m) 0.080 (L = 2 m), 0.180 (L = 5 m), 0.350 (L = 10 m)
Characteristics
Wiring configuration, PNP/NPN
Degree of protection
–
–
PNP wiring
IP 67
NPN wiring
IP 67
IP 67
IP 67
Ambient air temperature
Number of wires and c.s.a.
LED indication
-35…+80 °C
4 x 0.25 mm2
No
-35…+80 °C
4 x 0.25 mm2
No
-35…+80 °C
3 x 0.25 mm2
2 LEDs
-35…+80 °C
3 x 0.25 mm2
2 LEDs
Associated sensor references
Dimensions
XSi-iiiiiiiiD
XSi-iiiiiiiiD
XSi-iiiiiiiiD
XSi-iiiiiiiiD
XZ-CP1141Li
XZ-CP1241Li
M12x1
XZ-CP1340Li, XZ-CP1440Li
M12x1
XZ-CP1865Li
XZ-CP1965Li
Ø14,5
M12x1
Ø14,5
1/2" 20 UNF
26
26
27
1/2" 20 UNF
(1)
20
20
20
(1) 2 LEDs,
voltage limits
a 10…30 V max.
L = 2, 5 or 10 m
Connection schemes
XZ-CP1i41Li
XZ-CP1i41Li
LED connections
XZ-CP1340Li
PNP
BN
1
XZ-CP1i65Li
XZ-CP1440Li
GN
1
NPN
BU
BU
BK
4
BK
4
BU
–
+
3
3
3
BK
4
BK
4
Signal
Signal
YW
2
YW
2
3
2
2
1
2
1
GN
GN
RD/WH
RD/BK
WH
BN
BN
+
BU
3
–
BN
1
3/58
Te
Inductive proximity sensors
Female connectors (continued) and sensor fixing accessory
References, characteristics, dimensions, schemes
Connector type No
Number of pins
13
14
3
3
Female connector version
References
1/2" 20 UNF straight
1/2" 20 UNF straight
PVR cable connection,
Ø 5 mm
L = 2 m
L = 5 m
L = 10 m
XZ-CP1865L2
XZ-CP1965L2
XZ-CP1965L5
XZ-CP1965L10
XZ-CP1865L5
3
XZ-CP1865L10
Weight (kg)
0.080 (L = 2 m), 0.180 (L= 5 m), 0.350 (L = 10 m)
Characteristics
Wiring configuration, PNP/NPN
Degree of protection
–
–
IP 67
IP 67
Ambient air temperature
Number of wires and c.s.a.
LED indication
-35…+80 °C
3 x 0.34 mm2
No
-35…+80 °C
3 x 0.34 mm2
No
Associated sensor references
XSi-iiiiiiiiK
XSi-iiiiiiiiK
Dimensions and connection schemes
Shown on previous page
Saddle clamp fixing accessory for cylindrical type sensors
Description
For use with sensors
Type
Reference
Weight
kg
Diameter (mm)
4 (plain)
Saddle clamps
XS1
XSZ-B104
XSZ-B105
XSZ-B165
XSZ-B108
XSZ-B112
XSZ-B118
XSZ-B130
0.005
0.005
0.005
0.006
0.006
0.010
0.020
5 (M5 x 0.5)
6.5 (plain)
XS1, XS2
XS1, XS2, XS4
8 (M8 x 1)
12 (M12 x 1)
18 (M18 x 1)
30 (M30 x 1.5)
XSZ-B1ii
XS1, XS2, XS4
3/59
Te
相关型号:
©2020 ICPDF网 联系我们和版权申明