ZEN2G [ETC]
GRENZTASTER IP65 MIT STOESSEL ; GRENZTASTER IP65 MIT斯托塞尔\n型号: | ZEN2G |
厂家: | ETC |
描述: | GRENZTASTER IP65 MIT STOESSEL
|
文件: | 总28页 (文件大小:469K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
General-purpose Basic Switch
Z
Best-selling Basic Switch Boasting High
Precision and Wide Variety
A
large switching capacity of 15 A with high repeat
accuracy.
Wide margins of operating conditions with a wide
operating speed range.
A wide range of variations in contact form for your
selection: basic, split contact, maintained contact,
and adjustable contact gap types.
A series of standard models for minute loads is
available.
A series of molded terminal-type models incorpo-
rating safety terminal protection cover is available.
Including models that meet the quality require-
ments of the RCJ under license number RCJ-17-4.
Ordering Information
Configuration
that the switch is resistant to humidity, oil, and dust. The degree of
protection conforms to JIS C0920 drip-proof II.
Basic Models
General-purpose
variety of actuators is available for a wide range of application.
The electric insulation of the molded terminals is ensured because
A
the terminal part is fixed with epoxy resin. The actuator and termi
-
nals are both sealed and thus resist water, oil, or dust. The lead
The contact mechanism of models for minute loads is a crossbar
wires can be stretched in either direction. Refer to page 43 for de
-
type with gold-alloy contacts, which ensures highly reliable opera
tions for minute loads.
-
tails.
Contact Gap:
Fixed contact
H: 0.25 mm (high-sensitivity, microvoltage current load)
G: 0.5 mm (standard)]
E: 1.8 mm (high-capacity)
(NC)
Rubber boot
Glued surface (adhesive is
filled between case and cover)
Movable spring
Contact Form
Movable contact
Spring pivot
Fixed contact
(NO)
COM
NO
NC
With Terminal Cover
Note: The Z-15GM is a reversible model and the NO and
The high sealing capability (drip-proof) and the terminal protection
allows switching operations under poor environment with water and
NC positions are reversed.
dust, like limit switches. Furthermore, these switches are inexpen
sive.
-
Drip-proof Models
The easy-to-remove terminal protection cover allows the easy
maintenance of the wires.
There is no difference in basic configuration and switching mecha
nism between drip-proof models and standard models, and a vari
-
-
ety of actuators can be used with drip-proof models. Drip-proof
models use weather-resistive chloroprene rubber
By changing the terminal protection cover position, the cable can be
stretched in the left or right direction.
.
Without Terminal Cover
The width of this model is the same as that of the conventional Z
model. Therefore this model can be mounted under the same condi
tions.
-
The pin plunger is sealed from the other switch mechanisms by a
resilient rubber, and the case and cover are sealed by adhesive so
19
Z
Z
Rubber boot (weather-resistive
chloroprene is used)
Connection Example
Series Connection
Parallel Connection
topper
g)
L
L
L
L
Rubber packing (improves
sealing between switch
L
L
housing and terminal cover)
Terminal protection covers are sold separately
for maintenance purposes, which can be, how-
ever, used with the Z-B5V-series models only.
Cable Sealing Rubber
Maintained Contact Models
The maintained contact type has a reset button at the bottom of the
switch case, in addition to the push button (plunger) located on the
Two- or three-conductor VCT (with a nominal cross section of 0.75
2
or 1.25 mm can be used.
opposite side of the reset button. Use these buttons alternately
.
Split Contact Models
This type is identical in construction to the general-purpose basic
switch except that it has two pairs of simultaneous acting contacts
by splitting moving contacts.
Since the switch has greater pretravel than overtravel, it is suitable
for use in reversible control circuits, manual reset circuits, safety
limit circuits, and other circuits which are not preferable for automat
-
ic resetting.
Since the moving contacts are connected to a common terminal, ei
ther parallel or series connection is possible.
-
Contact Form
Highly reliable minute load switching is ensured if the model is used
as a twin-contact switch.
Current capacity: 10 A
Contact Form
COM
NO
NC
Push button for resetting
COM
NO
NC NC
NO
Note: The Z-10FM is a reversible model and the NO and
NC positions are reversed.
20
Z
Z
Ordering Information
Basic model (general-purpose)
Actuator
Split contact
Standard
High-sensitivi High-capacity
ty
Microload
G (0.5 mm)
H (0.25 mm)
Z-15H
E (1.8 mm)
Z-15E
H (0.25 mm)
Z-01H
F (1.0 mm)
---
Pin plunger
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Z-15G
Z-15G-B
Z-15H-B
Z-15HS
Z-15HS-B
Z-15HD
Z-15HD-B
---
Z-15E-B
---
Z-01H-B
Z-01HS
Z-01HS-B
Z-01HD
Z-01HD-B
---
Z-10FY-B
Slim spring plunger
Z-15GS
---
Z-15GS-B
Z-15GD
Z-10FSY-B
Short spring
plunger
---
---
---
Z-15GD-B
Z-15GQ3
Z-15GQ3-B
Z-15GQ
Z-10FDY-B
---
Panel mount
plunger
Low OP
Medium OP
High OP
Z-15HQ
Z-15HQ-B
---
Z-15EQ
Z-15EQ-B
---
Z-01HQ
Z-01HQ-B
---
---
Z-15GQ-B
Z-15GQ8
Z-15GQ8-B
Z-15GQ22
Z-15GQ22-B
Z-15GQ21
Z-15GQ21-B
Z-15GL
Z-10FQY-B
---
Panel mount roller
plunger
Z-15HQ22
Z-15HQ22-B
Z-15HQ21
Z-15HQ21-B
---
Z-15EQ22
Z-15EQ22-B
---
---
---
Z-10FQ22Y-B
---
Panel mount cross
roller plunger
---
---
---
Leaf spring
---
---
---
---
Z-15GL-B
Z-15GL2
Roller leaf spring
Z-15HL2
Z-15HL2-B
---
Z-15GL2-B
Z-15GW21
Z-15GW21-B
Z-15GW
Short hinge lever
Hinge lever
---
---
---
---
---
---
---
---
---
---
---
Low OF
Z-15HW
Z-15HW-B
---
---
Z-15GW-B
Z-15GW3
Z-15GW3-B
Z-15GW32
Z-15GW32-B
Z-15GW4
Z-15GW4-B
---
Z-10FWY-B
---
Medium OF
High OF
---
---
Low-force hinge lever
Z-15HW4
Z-15HW4-B
Z-15HW78
Z-15HW78-B
Z-15HW52
Z-15HW52-B
Z-15HW22
Z-15HW22-B
---
Low-force wire
hinge lever
Low OF
High OF
---
---
---
---
---
---
---
Short hinge roller lever
Z-15GW22
Z-15GW22-B
Z-15GW49
Z-15GW49-B
Z-15GW2
Z-15EW22
Z-15EW22-B
---
Z-01HW22
Z-01HW22-B
---
---
Z-10FW22Y-B
---
Short hinge cross
roller lever
HInge roller lever
Parallel
Z-15HW2
Z-15HW2-B
---
---
---
---
---
---
---
---
---
---
Z-15GW2-B
Z-15GW25
Z-15GW25-B
Z-15GW54
Z-15GW54-B
Z-15GW2277
Z-10FW2Y-B
---
Large roller
Hinge cross
roller lever
---
---
---
---
Unidirectional short
hinge roller lever
Screw terminal
Z-15GW2277-B
Reverse hinge lever
(see note 2)
Solder terminal
Screw terminal
Z-15GM
---
---
---
---
Z-15GM-B
21
Z
Z
Actuator
Basic model (general-purpose)
Splliitt ccoonnttaact
Standard
High-sensitivi High-capacity
ty
Microload
G (0.5 mm)
H (0.25 mm)
---
E (1.8 mm)
---
H (0.25 mm)
F (1.0 mm)
---
Reverse short hinge
roller lever (see note
2)
Solder terminal
Screw terminal
Z-15GM22
---
Z-15GM22-B
Z-10FM22Y-B
---
Reverse hinge roller lever
(see note 2)
Solder terminal
Screw terminal
Z-15GM2
---
---
---
Z-15GM2-B
Note: 1. A super high-sensitivity model with a 0.2 mm contact gap, Z-15H2(-B), is also available.
2. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin
plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers
are normally pressed.
Actuator
Basic model (drip-proof)
Microload
Standard
High-sensitivity
H (0.25 mm)
G (0.5 mm)
H (0.25 mm)
Without
drip-proof
terminal
With drip-proof
terminal protection
cover
Without
drip-proof
terminal
Without
drip-proof
terminal
protection cover
protection cover protection cover
Pin plunger
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Z-15G55
---
Z-01H55
Z-01H55–B
Z-01HD55
Z-01HD55-B
---
---
---
---
---
---
---
---
---
---
Z-15G55-B
Z-15GD55
Z-15GA55-B5V
---
Short spring plunger
Spring plunger
Z-15GD55-B
Z-15GK55
Medium OP
High OP
---
Z-15GK55-B
Z-15GK355
Z-15GK355-B
Z-15GQ55
---
---
---
---
---
---
---
Z-15GK3A55-B5V
Panel mount
plunger
Medium OP
---
Z-15GQ55-B
Z-15GQ2255
Z-15GQ2255-B
Z-15GQ2155
Z-15GQ2155-B
Z-15GL55
Z-15GQA55-B5V
Panel mount
roller plunger
---
Z-15GQ22A55-B5V
Panel mount cross
roller plunger
---
Z-15GQ21A55-B5V
---
Leaf spring
Z-15GL55-B
Z-15GL255
Roller leaf spring
---
---
Screw terminal
Z-15GL255-B
Short hinge lever
Hinge lever
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Z-15GW2155
Z-15GW2155-B
Z-15GW4455
Z-15GW4455-B
Z-15GW55
---
---
---
---
---
---
---
Medium OF
High OF
---
Z-15GW44A55-B5V
---
Z-15GW55-B
Z-15GW2255
Z-15GWA55-B5V
---
Short hinge
roller lever
Z-01HW2255
Z-01HW2255-B
---
Screw terminal
Solder terminal
Z-15GW2255-B
Z-15GW255
Z-15GW22A55-B5V
---
Hinge roller lever
Parallel
---
Screw terminal
Z-15GW255-B
Z-15GW2A55-B5V
---
Unidirectional short
hinge roller lever
Solder terminal
Screw terminal
Z-15GW227755
---
---
---
---
Z-15GW227755-B Z-15GW2277A55-B5V
Reverse hinge lever
(see note)
Solder terminal
Screw terminal
Z-15GM55
---
Z-15GM55-B
22
Z
Z
Actuator
Basic model (drip-proof)
Microload
Standard
High-sensitivity
G (0.5 mm)
H (0.25 mm)
H (0.25 mm)
Without
drip-proof
terminal
With drip-proof
terminal protection
cover
Without
drip-proof
terminal
Without
drip-proof
terminal
protection cover
protection cover protection cover
Reverse short hinge
roller lever (see note)
Solder terminal
Screw terminal
Solder terminal
Screw terminal
Solder terminal
Z-15GM2255
Z-15GM2255-B
Z-15GM255
---
---
---
Reverse hinge roller
lever (see note)
---
---
---
---
---
Z-15GM255-B
Z-15GNJ55
Flexible rod (coil spring)
Z-15HNJS55
Screw terminal
Z-15GNJ55-B
Z-15HNJS55-B
Note: The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin
plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers
are normally pressed.
Actuator
Maintained contact model
Pin plunger
Z-15ER
Slim spring plunger
Hinge lever
Z-15ESR
Z-15EWR
Model Number Legend
Z-jjjj-j
1
2
3
4
5
1. Rated Current
01: 0.1 A (for microload)
W78: Low-force wire hinge lever (low OF) (see note 2)
W52: Low-force wire hinge lever (high OF) (see note 2)
W22: Short hinge roller lever
15: 15 A
W2:
Hinge roller lever (parallel)
2. Contact Gap
W25: Hinge roller lever (large roller)
H: 0.25 mm (high-sensitivity)
W2277:Unidirectional short hinge roller lever
G: 0.5 mm (standard)
M:
Reverse hinge lever (see note 1)
E: 1.8 mm (high-capacity)
M22: Reverse short hinge roller lever (see note 1)
3. Actuator
None: Pin plunger
M2:
NJ:
Reverse hinge roller lever (see note 1)
Flexible rod (low OF)
S:
Slim spring plunger
NJS: Flexible rod (high OF)
D:
Short spring plunger
Note: 1. Applicable to the Z-15F only. Refer to “Ordering
K:
Spring plunger (medium OP)
Spring plunger (high OP)
Information” for the other models.
K3:
Q3:
Q:
2. Applicable to the Z-15H only
.
Panel mount plunger (low OP)
Panel mount plunger (medium OP)
Panel mount plunger (high OP)
4. Enclosure ratings
None: General-purpose
55: Drip-proof
Q8:
Q22: Panel mount roller plunger
A55: Drip-proof (including the terminals)
5. Terminals
None: Solder terminal
Q21: Panel mount cross roller plunger
L:
Leaf spring
L2:
Roller leaf spring
B:
Screw terminal (with cup washer)
Screw terminal (with toothed washer)
W21: Short hinge lever
B3:
W:
Hinge lever (low OF)
B5V: Screw terminal with terminal cover (for Z-15GjA55
W3:
Hinge lever (medium OF)
only)
W32: Hinge lever (high OF) (see note 1)
W4: Low-force hinge lever (see note 1)
23
Z
Z
Specifications
Ratings
Basic (Except Microload and Flexible Rod Models)/Maintained Contact Models
Non-inductive load
Inductive laod
Inductive load Motor load
NC NO NC NO
Resistive load
NC NO
Lamp load
NC NO
Model
G, H, E
Rated voltage
125 VAC
250 VAC
500 VAC
8 VDC
15 (10) A (see note)
3 A
1.5 A
1.25 A
0.75 A
1.5 A
1.5 A
1.5 A
0.5 A
0.25 A
1.5 A
1.5 A
1.4 A
0.4 A
0.2 A
1.5 A
1.5 A
1.5 A
0.75 A
0.3 A
15 (10) (see note)
5 A
2.5 A
1.5 A
0.75 A
2.5 A
2.5 A
2.5 A
0.05 A
0.03 A
2.5 A
2.5 A
1 A
15 (10) A (see note)
10 A
2.5 A
1.5 A
3 A
15 (10) (see note)
6 A
3 A
1.5 A
5 A
G
H
E
15 A
15 A
14 VDC
15 A
3 A
10 A
5 A
30 VDC
6 A
3 A
5 A
5 A
125 VDC
250 VDC
8 VDC
0.5 A
0.25 A
15 A
0.5 A
0.25 A
3 A
0.05 A
0.03 A
15 A
0.05 A
0.03 A
5 A
14 VDC
15 A
3 A
10 A
5 A
30 VDC
2 A
2 A
1 A
1 A
125 VDC
250 VDC
8 VDC
0.4 A
0.2 A
15 A
0.4 A
0.2 A
3 A
0.03 A
0.02 A
15 A
0.03 A
0.02 A
5 A
0.03 A
0.02 A
2.5 A
2.5 A
2.5 A
0.4 A
0.2 A
14 VDC
15 A
3 A
15 A
5 A
30 VDC
15 A
3 A
10 A
5 A
125 VDC
250 VDC
0.75 A
0.3 A
0.75 A
0.3 A
0.4 A
0.2 A
0.4 A
0.2 A
Note: Figures in parentheses are for the Z-15H2-series, Z-15HW52, and Z15HW78(-B) models, the AC ratings of these models are 125 and
250 V only
.
Basic (Microload) Models
Rated voltage
Resistive load
NC NO
0.1 A
125 VAC
8 VDC
0.1 A
0.1 A
0.1 A
14 VDC
30 VDC
Basic (Flexible Rod) Models
Rated voltage
Non-inductive load
Resistive load Lamp load
NC NO NC NO
15 A
Inductive laod
Inductive load Motor load
NC NO NC NO
125 VAC
250 VAC
8 VDC
2 A
1 A
7 A
5 A
7 A
7 A
1 A
2.5 A
1.5 A
3 A
2 A
15 A
15 A
15 A
2 A
1 A
0.5 A
1 A
1 A
2 A
1.5 A
1.5 A
0.5 A
0.03 A
0.02 A
14 VDC
30 VDC
125 VDC
250 VDC
2 A
1 A
3 A
2 A
1 A
1 A
0.4 A
0.2 A
0.4 A
0.2 A
0.4 A
0.2 A
0.03 A
0.02 A
0.03 A
0.02 A
24
Z
Z
Split Contact Models
Model
Rated voltage
Non-inductive load
Resistive load Lamp load
NC NO NC NO
10 A
Inductive laod
Inductive load Motor load
NC NO NC NO
Series
connection
125 VAC
250 VAC
30 VDC
4 A
2 A
6 A
6 A
6 A
5 A
2.5 A
1.5 A
3 A
10 A
10 A
1 A
2.5 A
4 A
1.5 A
2 A
3 A
6 A
125 VDC
250 VDC
125 VDC
250 VDC
30 VDC
1 A
1 A
0.1 A
0.05 A
4 A
0.1 A
0.05 A
4 A
0.1 A
0.05 A
2 A
0.6 A
6 A
0.6 A
3 A
0.6 A
1.5 A
1.25 A
2 A
Parallel
connection
6 A
2.5 A
4 A
4 A
2 A
1 A
6 A
4 A
6 A
3 A
125 VDC
250 VDC
0.6 A
0.3 A
0.6 A
0.3 A
0.6 A
0.3 A
0.1 A
0.05 A
0.1 A
0.05 A
0.1 A
0.05 A
Note: 1. The above current ratings are the values of the steady-state current.
2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The normally closed and normally open ratings of reverse hinge lever models are opposite to each other
.
6. The AC ratings of molded terminals are 125 and 250 V only
.
Characteristics
Item
Basic (except
microload and
flexible rod)/
maintained
contact
Basic
(microload)
Basic (flexible rod: coil spring,
steel wire)
Split contact
Operating speed
(see note)
0.01 mm to 1 m/s (at pin plunger)
1 mm to 1 m/s
0.1 mm to 1 m/s (at pin plunger)
Operating frequency
Mechanical: 240 operations/min
Electrical: 20 operations/min
Mechanical: 120 operations/min
Electrical: 20 operations/min
Mechanical: 240 operations/min
Electrical: 20 operations/min
Insulation resistance 100 M
Ω
min. (at 500 VDC)
max. 50 m
(initial value) (initial value)
Contact resistance
15 m
Ω
Ω
max.
15 mΩ
max. (initial value)
25 mΩ max. (initial value)
Dielectric strength
Between contacts of same polarity
Between contacts of same
polarity
Between contacts of same
polarity
Contact gap G: 1,000 VAC, 50/60 Hz
for 1 min
Contact gap G: 1,000 VAC,
50/60 Hz for 1
min
Contact gap F: 1,500 VAC, 50/
60 Hz for 1 min
Contact gap H: 600 VAC, 50/60 Hz
for 1 min
Between current-carrying metal
parts and ground, and between
each terminal and
Contact gap H: 600 VAC, 50/
60 Hz for 1 min
contact gap E: 1,500 VAC, 50/60 Hz
for 1 min
non-current-carrying metal parts
Between current-carrying metal
parts and ground, and between
each terminal and
Between current-carrying metal parts
and ground, and between each
terminal and non-current-carrying
metal parts
2,000 VAC, 50/60 Hz for 1 min
non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min
2,000 VAC, 50/60 Hz for 1 min
Inrush current
NO: 15 A max.
NC: 30 A max.
NO: 0.1 A max.
NC: 0.1 A max.
NO: 10 A max.
NC: 20 A max.
NO: 20 A max.
NC: 40 A max.
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm
double amplitude
Malfunction: 10 to 20 Hz, 1.5-mm Malfunction: 10 to 55 Hz, 1.5-mm
double amplitude double amplitude
2
2
2
Shock resistance
Destruction: 1,000 m/s min.
Destruction: 1,000 m/s min.
(approx. 100G
Destruction: 1,000 m/s min.
(approx. 100G
(approx. 100G min.)
min.)
min.)
2
Malfunction: 300 m/s min. (approx.
2
2
30G min.) (Z-15G pin
Malfunction: 50 m/s min.
Malfunction: 300 m/s min.
plunger)
(approx. 5G min.)
(approx. 30G min.)
(Z-10FY-B)
25
Z
Z
Item
Basic (except
microload and
flexible rod)/
maintained
contact
Basic
(microload)
Basic (flexible rod: coil spring,
steel wire)
Split contact
Life expectancy
Mechanical:
Contact gap G, H, H2: 20,000,000
Mechanical: 1,000,000
operations min. (at
pin plunger)
Mechanical: 500,000
operations min. (at
pin plunger)
operations
min. (at pin
plunger)
Electrical:
100,000
operations min.
Electrical:
100,00 operations
min.
Contact gap E:
Electrical:
300,000
operations
Contact gap G, H, H2: 500,000
operations
min. (at pin
plunger)
Contact gap E:
100,000
operations
Ambient temperature Operating:
General-purpose: –25°C to 80
°
C (with no icing)
C (with no icing)
Drip-proof:
–15°C to 80
°
Ambient humidity
Operating:
General-purpose: 35% to 85%
Drip-proof: 35% to 95%
Specification: Rivet
Contact
Weight
Specification: Single crossbar
Materials: Gold alloy
Specification: Rivet
Materials:
Sliver alloy
Materials:
Silver alloy
Approx. 22 to 58 g
Approx. 42 to 48 g
Approx. 34 to 61 g
Operating Characteristics
Basic (General-purpose)/Split Contact Models
Model
Pin plunger
Z-15G-B
Z-15H-B
Z-15H2-B (highly
sensitive models)
Z-15E-B
Z-01H-B
Z-10FY-B
OF
2.45 to 3.43 N
(250 to 350 gf)
1.96 to 2.75 N
(200 to 280 gf)
1.96 to 2.50 N
(200 to 255 gf)
6.12 to 7.84 N
(625 to 800 gf)
2.45 N
(250 gf)max.
4.46 to 7.25 N
(455 to 740 gf)
RF min.
PT max.
OT min.
MD max.
OP
1.12 N (114 gf)
0.4 mm
1.12 N (114 gf)
0.3 mm
1.12 N (114 gf)
0.3 mm
1.12 N (114 gf)
0.8 mm
0.78 N (80 gf)
0.5 mm
1.12 N (114 gf)
0.8 mm
0.13 mm
0.13 mm
0.1 mm
0.13 mm
0.13 mm
0.13 mm
0.05 mm
0.025 mm
0.005 to 0.008 mm 0.13 mm
0.04 mm
0.1 mm
15.9±0.4 mm
Model
OF
Slim spring plunger
Z-15ES-B
Z-15GS-B
Z-15HS-B
Z-01HS-B
Z-10FSY-B
2.45 to 3.43 N (250 to 1.96 to 2.80 N (200 to 6.12 to 7.84 N (625 to 2.45 N (250 gf) max.
4.46 to 7.25 N (455 to
740 gf)
350 gf)
285 gf)
800 gf)
RF min.
PT max.
OT min.
MD max.
OP
1.12 N (114 gf)
0.4 mm
1.12 N (114 gf)
0.3 mm
1.12 N (114 gf)
0.8 mm
0.78 N (80 gf)
0.5 mm
1.12 N (114 gf)
0.8 mm
1.6 mm
1.6 mm
1.6 mm
1.6 mm
1.6 mm
0.05 mm
0.025 mm
0.13 mm
0.05 mm
0.1 mm
28.2±0.5 mm
Model
OF
Short spring plunger
Z-15ED-B
Z-15GD-B
Z-15HD-B
Z-01HD-B
Z-10FDY-B
2.45 to 3.43 N (250 to 1.96 to 2.79 N (200 to 6.12 to 7.85 N (625 to 2.45 N (250 gf) max.
4.46 to 7.25 N (455 to
740 gf)
350 gf)
285 gf)
800 gf)
RF min.
PT max.
OT min.
MD max.
OP
1.12 N (114 gf)
0.4 mm
1.12 N (114 gf)
0.3 mm
1.12 N (114 gf)
0.8 mm
0.78 N (80 gf)
0.5 mm
1.12 N (114 gf)
0.8 mm
1.6 mm
1.6 mm
1.6 mm
1.6 mm
1.6 mm
0.05 mm
0.025 mm
0.13 mm
0.05 mm
0.1 mm
21.5±0.5 mm
26
Z
Z
Model
Panel mount plunger
Z-15GQ-B
(see note 1)
Z-15HQ-B
(see note 1)
Z-15EQ-B
(see note 1)
Z-01HQ-B
(see note 1)
Z-10FQY-B
(see note 1)
Z-15GQ3-B
(see note 2)
Z-15GQ8-B
(see notes 3
and 4)
OF
2.45 to 3.43 N
1.96 to 2.79 N
6.12 to 7.85 N
2.45 N (250 gf
4.46 to 7.25 N
(455 to 740 gf) (250 to 350 gf) (250 to 350 gf)
2.45 to 3.43 N
2.45 to 3.43 N
(250 to 350 gf) (200 to 285 gf) (625 to 800 gf) max.)
RF min.
PT max.
OT min.
MD max.
OP
1.12 N (114 gf) 1.12 N (114 gf) 1.12 N (114 gf) 0.78 N (80 gf)
1.12 N (114 gf) 1.12 N (114 gf) 1.12 N (114 gf)
0.4 mm
0.3 mm
0.8 mm
5.5 mm
0.13 mm
0.5 mm
5.5 mm
0.05 mm
0.8 mm
5.5 mm
0.1 mm
4.2 mm
0.5 mm
5.5 mm
5.5 mm
2.5 mm
5.5 mm
0.05 mm
21.8±0.8 mm
0.025 mm
2.2 mm
0.05 mm
32.5±1 mm
18.8±0.8 mm
Note: 1. Do not use the M12 mounting screw and the case mounting hole at the same time, or excessive pulling force will be imposed on the
switch and the case and cover may be damaged.
2. The pretravel of the Z-15GQ3-B can be larger than that of the Z-15GQ. Do not use the M12 mounting screw and the case mounting
hole at the same time, or the case may be damaged.
3. The operating position of the Z15GQ8-B can be adjusted by attaching a screw to the pin plunger. Do not use the M12 mounting
screw and the case mounting hole at the same time, or the case may be damaged.
4. The M3 hole with a depth of 10 mm is a through hole. Take precautions so that no water or screw lock agent penetrates into the hole.
Model
Panel mount roller plunger
Panel mount cross roller plunger
Z-15GQ22-B
Z-15HQ22-B
Z-15EQ22-B
Z-10FQ22Y-B
Z-15GQ21-B
Z-15HQ21-B
Z-15EQ21-B
OF
2.45 to 3.43 N
1.96 to 2.79 N
6.12 to 7.85 N
4.46 to 7.25 N
2.45 to 3.43 N
1.96 to 2.79 N
6.12 to 7.85 N
(250 to 350 gf) (200 to 285 gf) (625 to 800 gf) (455 to 740 gf) (250 to 350 gf) (200 to 285 gf) (625 to 800 gf)
RF min.
PT max.
OT min.
MD max.
OP
1.12 N (114 gf) 1.12 N (114 gf) 1.12 N (114 gf) 1.12 N (114 gf) 1.12 N (114 gf) 1.12 N (114 gf) 1.12 N (114 gf)
0.4 mm
0.3 mm
0.5 mm
1 mm
0.4 mm
0.3 mm
0.5 mm
3.58 mm
0.05 mm
33.4±1.2 mm
3.58 mm
0.025 mm
3.58 mm
0.13 mm
3.55 mm
0.1 mm
3.58 mm
0.05 mm
3.58 mm
0.025 mm
3.58 mm
0.13 mm
Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged.
Model
Leaf spring
Z-15GL-B
Roller leaf spring
Short hinge lever
Z-15GW21-B
Z-15GL2-B
1.38 N (141 gf)
Z-15HL2-B
1.11 N (113 gf)
OF max.
RF min.
OT min.
MD max.
FP max.
OP
1.38 N (141 gf)
1.57 N (160 gf)
0.14 N (14 gf)
1.6 mm (see note)
1.3 mm
0.14 N (14 gf)
1.6 mm (see note)
1.3 mm
0.14 N (14 gf)
1.6 mm (see note)
0.8 mm
0.27 N (28 gf)
2 mm
1 mm
20.6 mm
31.8 mm
24.8 mm
19±0.8 mm
17.4±0.8 mm
28.6±0.8 mm
Note: When operating, be sure not to exceed 1.6 mm.
Model
Hinge lever
Z-15GW3-B
Z-15GW-B
Z-15HW-B
Z-15GW32-B
Z-10FWY-B
OF
0.78 N (80 gf) max.
0.69 N (70 gf) max.
0.66 N (67 gf) max.
1.47 to 1.96 N (150 to 0.88 N (90 gf) max.
200 gf)
RF min.
OT min.
MD max.
FP max.
OP
0.15 N (15.5 gf)
4.8 mm
0.14 N (14 gf)
5.6 mm
0.14 N (14 gf)
5.6 mm
0.92 N (94 gf)
5.6 mm
0.14 N (14 gf)
5.6 mm
1.12 mm
1.27 mm
0.63 mm
1.27 mm
2.4 mm
28.8 mm
28.2 mm
28.4 mm
28.2 mm
29.8 mm
19±0.8 mm
27
Z
Z
Model
Low-force hinge lever
Z-15GW4-B Z-15HW24-B
Low-force wire hinge lever (see note)
Z-15HW52-B Z-15HW78-B
0.06 N (6 gf) 0.04 N (4 gf)
OF max.
RF min.
PT max.
OT min.
MD max.
OP
0.27 N (28 gf)
0.034 N (3.5 gf)
10 mm
0.06 N (6 gf)
0.005 N (0.5 gf)
19.8 mm
0.005 N (0.5 gf)
8.3 mm
0.003 N (0.3 gf)
10 mm
5.6 mm
10 mm
5.6 mm
6 mm
1.27 mm
2 mm
0.65 mm
3 mm
19±0.8 mm
19.8±1.6 mm
19±1 mm
20±1 mm
Note: The AC rating is 10 A at 125 or 250 V
.
Model
Short hinge roller lever
Z-15GW22-B
1.57 N (160 gf)
0.41 N (42 gf)
2.4 mm
Z-15HW22-B
Z-15EW22-B
1.94 N (198 gf)
0.41 N (42 gf)
2.4 mm
Z-01HW22-B
1.57 N (160 gf)
0.27 N (28 gf)
2.4 mm
Z-10FW22Y-B
OF max.
RF min.
OT min.
MD max.
FP max.
OP
1.47 N (150 gf)
2.45 N (250 gf)
0.34 N (35 gf)
2.4 mm
0.41 N (42 gf)
2.4 mm
0.5 mm
0.45 mm
1.3 mm
0.5 mm
1 mm
32.5 mm
35.1 mm
32.5 mm
34.8 mm
30.2±0.4 mm
Model
Short hinge cross
roller lever
Hinge roller lever
Z-15GW49-B
1.67 N (170 gf)
0.41 N (42 gf)
2.4 mm
Z-15GW2-B
Z-15HW2-B
0.84 N (86 gf)
Z-10FW2Y-B
1.27 N (130 gf)
0.22 N (22 gf)
4 mm
Z-15GW25-B
0.98 N (100 gf)
0.21 N (21 gf)
4 mm
OF max.
RF min.
OT min.
MD max.
FP max.
OP
0.98 N (100 gf)
0.22 N (22 gf)
4 mm
0.22 N (22 gf)
4 mm
0.51 mm
1.02 mm
0.6 mm
2 mm
1.6 mm
33.3 mm
36.5 mm
37.4 mm
47.5 mm
31±0.4 mm
30.2±0.8 mm
41.2±0.8 mm
Model
Hinge cross roller lever
Unidirectional short hinge roller
lever
Reverse hinge lever
Z-15GW54-B
0.98 N (100 gf)
Z-15GW2277-B
1.67 N (170 gf)
0.41 N (42 gf)
2.4 mm
Z-15GM-B
OF max.
RF min.
OT min.
MD max.
FP max.
OP
1.67 N (170 gf)
0.22 N (22 gf)
4 mm
0.27 N (28 gf)
5.6 mm
1 mm
0.51 mm
0.89 mm
37.3 mm
31±0.8 mm
43.6 mm
23.8 mm
41.3±0.8 mm
19±0.8 mm
Model
Reverse short hinge roller lever
Z-15GM22-B Z-10FM22Y-B
6.37 N (650 gf)
Reverse hinge roller lever
Z-15GM2-B
2.35 N (240 gf)
OF max.
RF min.
OT min.
MD max.
FP max.
OP
5.28 N (538 gf)
1.67 N (170 gf)
2 mm
1.67 N (170 gf)
2 mm
0.55 N (56 gf)
4 mm
0.28 mm
0.56 mm
0.64 mm
31.8 mm
33 mm
35 mm
29.4±0.4 mm
29.4±0.4 mm
30.2±0.8 mm
28
Z
Z
Basic (Drip-proof) Models
Model
Pin plunger
Slim spring plunger
Short spring plunger
Z-15G55-B
Z-15GA55-B5V
Z-01H55-B
Z-15GD55-B
Z-01HD55-B
Z-15GK55-B
Z-15GK355-B
Z-15GK3A55-B5V
OF
2.45 to 4.22 N
(250 to 430 gf)
3.43 N (350 gf)
max.
5.30 N (540 gf)
max.
3.63 N (370 gf)
max.
5.30 N (540 gf)
max.
5.30 N (540 gf)
max.
RF min.
PT max.
OT min.
MD max.
OP
1.12 N (114 gf)
2.2 mm
0.78 N (80 gf)
2.2 mm
1.12 N (114 gf)
1.8 mm
0.78 N (80 gf)
1.9 mm
1.12 N (114 gf)
2.3 mm
1.12 N (114 gf)
2.4 mm
0.13 mm
0.13 mm
1.6 mm
1.6 mm
1.6 mm
3.5 mm
0.06 mm
0.06 mm
0.06 mm
0.06 mm
0.06 mm
0.06 mm
15.9±0.4 mm
21.5±0.5 mm
28.2±0.5 mm
37.8±1.2 mm
Model
Panel mount plunger
Z-15GQ55-B, Z-15GQA55-B5V
5.30 N (540 gf)
Panel mount roller plunger
Z-15GQ2255-B, Z-15GQ22A55-B5V
5.30 N (540 gf)
Panel mount corss roller plunger
Z-15GQ2155-B, Z-15GQ21A55-B5V
OF max.
RF min.
PT max.
OT min.
MD max.
OP
5.30 N (540 gf)
1.12 N (114 gf)
1.8 mm
1.12 N (114 gf)
1.8 mm
1.12 N (114 gf)
1.8 mm
5.5 mm
3.58 mm
3.58 mm
0.06 mm
0.06 mm
0.06 mm
21.8±0.8 mm
33.4±1.2 mm
Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged.
Model
Leaf spring
Z-15GL55-B
Roller leaf spring
Z-15GL255-B
Short hinge lever
Z-15GW2155-B
Long hinge lever
Z-15GW4455-B
Z-15GW44A55-B5V
OF max.
RF min.
OT min.
MD max.
FP max.
OP
1.96 N (200 gf)
1.96 N (200 gf)
1.86 N (190 gf)
0.88 N (90 gf)
0.14 N (14 gf)
1.6 mm (see note)
1.3 mm
0.14 N (14 gf)
1.6 mm (see note)
1.3 mm
0.27 N (28 gf)
2 mm
0.14 N (14 gf)
5.6 mm
1 mm
3.5 mm
20.6 mm
31.8 mm
25 mm
33 mm
17.5±0.8 mm
28.6±0.8 mm
19±0.8 mm
19±1.2 mm
Note: When operating, be sure not to exceed 1.6 mm.
Model
Hinge lever
Short hinge roller lever
Hinge roller lever
Z-15GW55-B
Z-15GWA55-B5V
Z-15GW2255-B
Z-15GW22A55-B5V
Z-01HW2255-B
Z-15GW255-B
Z-15GW2A55-B5V
OF max.
RF min.
OT min.
MD max.
FP max.
OP
0.98 N (100 gf)
1.96 N (200 gf)
1.96 N (200 gf)
1.27 N (130 gf)
0.14 N (14 gf)
5.6 mm
0.27 N (42 gf)
2.4 mm
0.27 N (28 gf)
2.4 mm
0.21 N (21 gf)
4 mm
2 mm
0.8 mm
0.8 mm
1.6 mm
28.2 mm
19±0.8 mm
32.9 mm
36.5 mm
30.2±0.4 mm
30.2±0.8 mm
Model
Unidirectional short hinge
roller lever
Reverse hinge lever
Z-15GM55-B
1.96 N (200 gf)
Reverse short hinge roller Reverse hinge roller lever
lever
Z-15GW227755-B
Z-15GW2277A55-B5V
Z-15GM2255-B
Z-15GM255-B
OF max.
RF min.
OT min.
MD max.
FP max.
OP
1.77 N (180 gf)
0.49 N (50 gf)
2.4 mm
5.69 N (580 gf)
2.65 N (270 gf)
0.27 N (28 gf)
5.6 mm
1.67 N (170 gf)
2 mm
0.55 N (56 gf)
4 mm
0.8 mm
0.89 mm
0.28 mm
0.64 mm
35 mm
43.6 mm
23.8 mm
31.8 mm
41.3±0.8 mm
19±0.8 mm
29.4±0.4 mm
30.2±0.8 mm
29
Z
Z
Model
Flexible rod (coil spring)
Z-15GNJ55-B
Flexible rod (steel wire)
Z-15HNJS55-B
OF max.
PT max.
0.49 N (50 gf)
(20 mm)
0.15 N (15 gf)
(25 mm)
Maintained Contact Models
Model
Pin plunger
Z-15ER
Slim spring plunger
Z-15ESR
Push button
Reset button
OF
1.96 to 2.50 N (200 to 255 gf)
0.4 mm
2.65 N (270 gf) max.
PT max.
OT min.
OP
0.4 mm
0.13 mm
1.6 mm
15.9±0.4 mm
28.2±0.5 mm
2.79 N (285 gf) max.
0.4 mm
OF
0.55 to 2.79 N (56 to 285 gf)
0.4 mm
OT min.
Model
Hinge lever
Z-15EWR
Lever
OF max.
OT min.
OP
0.54 N (55 gf)
5.6 mm
19±0.8 mm
28.2 mm
FP max.
OF max.
OT min.
Reset button
2.94 N (300 gf)
0.4 mm
Engineering Data
Mechanical Life Expectancy
Electrical Life Expectancy
Z-15G
Z-15G
Operating frequency:
20 operations/min.
Without load
Operating frequency: 240 operations/min.
100
70
50
125 VAC cosφ = 1
125 VAC cosφ = 0.4
250 VAC cosφ = 1
10
5
30
20
250 VAC
cosφ = 0.4
10
7
5
1
3
0.5
2
1
500 VAC cosφ = 1
500 VAC cosφ = 0.4
0.1
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7
0
2
4
6
8
10
12
14 16
Overtravel (mm)
Overtravel (mm)
30
Z
Z
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Basic (General-purpose)/Split Contact Models
Pin Plunger
Z-15G-B, Z-15E-B
Z-15H-B, Z-01H-B
2.3 dia.
+0.075
–0.025 dia. hole
23.3±0.25
4.2
PT
2.3SR (stainless steel plunger)
Z-15H2-B, Z-10FY-B
OP
24.2
9.2
+0.075
4.2
–0.025
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Slim Spring Plunger
Z-15GS-B, Z-01HS
Z-15HS-B, Z-10FSY-B
Z-15ES-B
23.3±0.25
5.2 dia.
4 dia.
PT
(See
note)
OP
9 dia.
24.2
+0.075
–0.025
9.2
Note: Stainless steep plunger
4.2
(flat, 1R chamfered)
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Short Spring Plunger
Z-15GD-B, Z-01HDS
Z-15HD-B, Z-10FDY-B
Z-15ED-B
12.3 dia.
10 dia.
23.3±0.25
12SR
(see
+0.075
–0.025 dia. hole
PT
4.2
7.15 dia.
OP
24.2
9.2
Note: Plated iron plunger
+0.075
–0.025
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Panel Mount Plunger
23.3±0.25
8.35 dia.
PT
Z-15GQ-B, Z-01HQ-B
Z-15HQ-B, Z-10FQY-B
Z-15EQ-B
11.9SR
(see
M12 ×
1
mounting screw
Two hexagonal nuts (2 t x 14
width across flats)
OP
13.1
Two lock nuts (2 t x 15.6 width across flats)
(See
note 2)
16.3
16 dia.
Note: 1. Stainless steel plunger
+0.075
–0.025
9.2
4.2
2. Imperfect screw part with a maxi-
mum length of 1.5 mm.
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
31
Z
Z
Z-15GQ3-B
23.3±0.25
8.35 dia.
PT
11.9SR
(see
M12 ×
mounting screw
1
Two hexagonal nuts (2 t x 14
width across flats)
OP
13.1
Two lock nuts (2 t x 15.6 width across flats)
(See
16.3 note 2)
16 dia.
+0.075
–0.025
9.2
4.2
+0.1
–0.05 dia.
Note: 1. Stainless steel plunger
4.36
2. Imperfect screw part with a maxi-
mum length of 1.5 mm.
17.45±0.2
25.4±0.1 11.9
49.2
Z-15GQ8-B
23.3±0.25
8SR
(see
note
8.35 dia.
PT
M3 x 10 (depth)
M12 ×
1
mounting screw
OP
Two hexagonal nuts (2 t x 14
width across flats)
13.1
Two lock nuts (2 t x 15.6 width across flats)
(See
note 2)
16 dia.
16.3
+0.075
–0.025
9.2
4.2
+0.1
–0.05 dia.
4.36
Note: 1. Plated brass plunger
17.45±0.2
2. Imperfect screw part with a maxi-
mum length of 1.5 mm.
25.4±0.1 11.9
49.2
Panel Mount Roller Plunger
23.3±0.25
Z-15GQ22-B, Z-15EQ22-B
Z-15HQ22-B, Z-10FQ22Y-B
12.7 × 4.8 dia. (stainless steel roller)
PT
Two hexagonal nuts (3 t x 17
width across flats)
OP
M12 ×
1
15.5
mounting screw
(See
note)
16.3
9.2
Note: Imperfect screw part with a
+0.075
–0.025
maximum length of 1.5 mm.
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Panel Mount Cross Roller Plunger
23.3±0.25
12.7 × 4.8 dia. (stainless steel roller)
Z-15GQ21-B, Z-15HQ21-B,
Z-15EQ21-B
PT
Two hexagonal nuts (3 t x 17
width across flats)
OP
M12 ×
mounting screw
1
15.5
(See
note)
16.3
9.2
Note: Imperfect screw part with
+0.075
4.2
–0.025
a maximum length of 1.5
mm.
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
32
Z
Z
Leaf Spring
t = 0.3 (see note)
49.6±0.8
Z-15GL-B
4.8
FP
OP
23.9
9.2
+0.07
4.2
–0.02
+0.1
4.36
–0.05 dia.
dia. hole
17.45±0.2
Note: Stainless spring steel lever
25.4±0.1 11.9
49.2
Roller Leaf Spring
9.5 × 4 dia. (plastic toller)
46±0.8
= 0.3
Z-15GL2-B
z-15HL2-B
t
FP OP
23.9
9.2
+
–
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
Note: Stainless spring steel lever
25.4±0.1 11.9
49.2
Short Hinge Lever
Z-15GW21-B
26.2
t = 1 (stainless steel lever)
4.9
28.2R
OP
13.9
FP
20.2
16.9
+0.075
–0.025
9.2
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
t = 1 (stainless steel lever)
4.9
Hinge Lever
Z-15GW3-B, Z-15GW32-B
Z-15GW-B, Z-10FWY-B
Z-15HW-B
63.5R
26.2
FP
OP
20.2
16.9
13.9
+0.075
–0.025
9.2
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1
11.9
49.2
Low-force Hinge Lever
Z-15GW4-B
t = 1 (stainless steel lever)
4.9
63.5R
26.2
PT
OP
20.2
16.9
13.9
9.2
+0.075
–0.025
4.2
+0.1
4.36
–0.05 dia.
17.45±0.2
25.4±0.1 11.9
49.2
33
Z
Z
t = 0.8 (stainless steel lever)
5
Z-15HW24-B
120R
26.2
2
PT
20.2
OP
16.9
13.9
+0.075
9.2
4.2
–0.025
+0.1
4.36
–0.05 dia.
17.45±0.2
25.4±0.1 11.9
49.2
Low-force Wire Hinge Lever
Z-15HW52-B
1 dia. (stainless steel wire lever)
3 max.
20.2
63.5R
26.2
PT
16.9
OP
13.9
+0.075
–0.025
9.2
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Z-15HW78-B
1 dia. (stainless steel wire lever)
3 max.
110R
26.2
PT
OP
20.2 16.9
13.9
9.2
+0.075
4.2
–0.025
+0.1
4.36
–0.05 dia.
17.45±0.2
25.4±0.1 11.9
49.2
Short Hinge Roller Lever
Z-15GW22-B, Z-01HW22-B
Z-15HW22-B, Z-10FW22Y-B
Z-15EW22-B
9.5 × 4 dia.
(plastic roller)
26.2
t = 1
(stainless steel
lever)
FP
20.2
4.36
OP
16.9
13.9
9.2
+0.075
–0.025
4.2
+0.1
–0.05 dia.
+0.075
–0.025 dia. hole
4.2
17.45±0.2
25.4±0.1 11.9
49.2
26.2
Short Hinge Cross Roller Lever
Z-15GW49-B
9.5 × 4 dia.
plastic roller)
t = 1
(stainless
steel lever)
FP
OP
20.2
16.9
13.9
4.2
9.2
+0.075
–0.025
4.2
+0.1
–0.05 dia.
+0.075
–0.025 dia. hole
4.36
17.45±0.2
25.4±0.1 11.9
49.2
34
Z
Z
t = 1
Hinge Roller Lever
(stainless steel lever)
26.2
9.5 × 4 dia.
(plastic roller)
Z-15GW2-B, Z-10FW2Y-B
Z-15HW2-B
48.5R
FP
20.2
4.36
OP
16.9
13.9
9.2
+0.075
–0.025
4.2
+0.075
–0.025 dia. hole
+0.1
–0.05 dia.
4.2
17.45±0.2
25.4±0.1 11.9
49.2
20 × 4 dia.
(plastic roller)
Z-15GW25-B
2R
26.2
t = 1
(stainless
steel lever)
FP
OP
20.2
16.9
13.9
9.2
+0.075
–0.025
4.2
+0.075
–0.025 dia. hole
+0.1
4.2
4.36
–0.05 dia.
17.45±0.2
25.4±0.1 11.9
49.2
9.5 × 4 dia.
(plastic roller)
t = 1
Hinge Cross Roller Lever
Z-15GW54-B
26.2
(stainless steel lever)
FP
OP
20.2
16.9
13.9
9.2
+0.075
–0.025
4.2
+0.075
–0.025 dia. hole
+0.1
–0.05 dia.
4.2
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Unidirectional Short Hinge Roller Lever
9.5 × 4 dia.
(plastic roller)
Operating direction
Z-15GW2277-B
t = 1
26.2
(stainless
steel lever)
31.9R
34.1 max.
11.1R
FP
OP
20.2
16.9
13.9
9.2
+0.075
4.2
+0.1
–0.025
+0.075
–0.025 dia. hole
4.2
4.36
–0.05 dia.
17.45±0.2
25.4±0.1 11.9
49.2
35
Z
Z
Reverse Hinge Lever
Note: The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin
plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers
are normally pressed.
Z-15GM-B
t = 1 (stainless steel lever)
4.9
4 max.
18.65
56R
FP
20.2
17.4
4.2
OP
13.9
4.2
9.2
+0.075
–0.025
+0.075
–0.025 dia. hole
+0.1
4.36
–0.05 dia.
17.45±0.2
25.4±0.1
11.9
49.2
Reverse Short Hinge Roller Lever
Note: The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin
plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers
are normally pressed.
Z-15GM22-B,
Z-10FM22Y-B
18.65
18.5R
9.5 × 4 dia.
(plastic roller)
t = 1 (stainless steel lever)
4 max.
17.4
FP
OP
20.2
13.9
9.2
+0.075
4.2
–0.025
+0.075
–0.025 dia. hole
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1
11.9
49.2
Reverse Hinge Roller Lever
Note: The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin
plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers
are normally pressed.
Z-15GM2-B
t = 1 (stainless steel lever)
18.65
9.5 × 4 dia.
(plastic roller)
4 max.
40.6R
FP
OP
20.2
17.4
13.9
9.2
+0.075
–0.025 dia. hole
+0.075
–0.025
4.2
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
36
Z
Z
Basic (Drip-proof) Models
+0.075
–0.025 dia. hole
Pin Plunger
4.2
23.3±0.25
6SR(see note)
Z-15G55-B,
3.9 dia.
Z-15GA55-B5V (With Termi-
nal Protection Cover),
Z-01H55-B
PT
OP
23.9
9.2
+0.075
–0.025
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
Note: Stainless steel plunger
25.4±0.1 11.9
49.2
Short Spring Plunger
+0.075
–0.025 dia. hole
11.9SR
(see note)
4.2
Z-15GD55-B,
Z-01HD55-B
15 dia.
23.3±0.25
PT
7.15 dia.
OP
23.9
9.2
+0.075
–0.025
4.2
Note: Stainless steel plunger
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
11.9SR
(see note)
Short Spring Plunger
Z-15GK55-B
17 dia.
23.3±0.25
PT
7.15 dia.
OP
23.9
9.2
+0.075
–0.025
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
Note: Stainless steel plunger
25.4±0.1 11.9
49.2
Z-15GK355-B,
Z-15GK3A55-B5V (With
11.9SR
(see note)
17 dia.
23.3±0.25
PT
Terminal Protection Cover)
7.15 dia.
+0.075
–0.025 dia. hole
4.2
OP
23.9
9.2
+0.075
–0.025
4.2
+0.1
4.36
–0.05 dia.
17.45±0.2
Note: Stainless steel plunger
25.4±0.1 11.9
49.2
37
Z
Z
Panel Mount Plunger
11.9SR
(see note 1)
8.35 dia.
23.3±0.25
PT
Z-15GQ55-B,
M12 x 1
mounting screw
Z-15GQA55-B5V (With Ter-
minal Protection Cover)
Two hexagonal nuts (2 t x 14
width across flats)
OP
See note 2
13.1
16.3
Two lock nuts (2 t x 15.6 width across flats)
16 dia.
+0.075
–0.025
9.2
Note: 1. Stainless steel plunger
4.2
2. Imperfect screw part with a
maximum length of 1.5 mm.
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
12.7 × 4.8 dia.
Panel Mount Roller Plunger
(see note 1)
23.3±0.25
PT
Z-15GQ2255-B,
Z-15GQ22A55-B5V (With Termi-
nal Protection Cover)
Two hexagonal nuts (3 t x 17
width across flats)
See note 2
15.5
M12 x 1
mounting screw
OP
16.3
+0.075
–0.025
9.2
4.2
Note: 1. Stainless steel plunger
2. Imperfect screw part with a
maximum length of 1.5 mm.
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Panel Mount Cross Roller Plunger
12.7 × 4.8 dia.
(see note 1)
23.3±0.25
Z-15GQ2155-B,
PT
Z-15GQ21A55-B5V (With Terminal
Protection Cover)
Two hexagonal nuts (3 t x 17
width across flats)
OP
See note 2
15.5
M12 x 1
mounting screw
16.3
+0.075
–0.025
9.2
4.2
+0.1
–0.05 dia.
4.36
Note: 1. Stainless steel plunger
17.45±0.2
2. Imperfect screw part with a
maximum length of 1.5 mm.
25.4±0.1 11.9
49.2
Leaf Spring
Z-15GL55-B
t = 0.3 (stainless steel lever)
4.8
+0.075
49.6±0.8
4.2
–0.025 dia. hole
FP
OP
23.9
+0.0
–0.0
9.2
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
38
Z
Z
Roller Leaf Spring
Z-15GL255-B
9.5 × 4 dia.
(plastic roller)
46±0.8
t
= 0.3
FP OP
23.9
9.2
+0.075
–0.025
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
Note: Stainless steel lever
25.4±0.1 11.9
49.2
Short Hinge Lever
Z-15GW2155-B
26.2
t = 1 (stainless steel lever)
4.9
28.2R
OP FP
13.9
20.2
16.9
+0.075
–0.025
4.2
9.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Long Hinge Lever
t = 1 (stainless steel lever)
4.9
26.2
Z-15GW4455-B
Z-15GW44A55-B5V (With
100R
Terminal Protection Cover)
20.2
OP FP
16.9
13.9
+0.075
–0.025
+0.075
–0.025 dia. hole
9.2
4.2
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Hinge Lever
Z-15GW55-B
Z-15GWA55-B5V (With Terminal
Protection Cover)
t = 1 (stainless steel lever)
4.9
26.2
63.5R
FP
OP
20.2
16.9
13.9
9.2
+0.075
–0.025
4.2
+0.075
–0.025 dia. hole
4.2
+0.1
4.36
–0.05 dia.
17.45±0.2
25.4±0.1 11.9
49.2
Short Hinge Roller Lever
t = 1 (stainless steel lever)
26.2
Z-15GW2255-B,
9.5 × 4 dia.
(plastic roller)
Z-15GW22A55-B5V (With Terminal
Protection Cover),
Z-01HW2255-B
26.6R
FP
OP
20.2
16.9
13.9
9.2
+0.075
–0.025
+0.075
4.2
4.2
–0.025 dia. hole
+0.1
–0.05 dia.
4.36
17.45±0.2
11.9
25.4±0.1
49.2
39
Z
Z
Roller Hinge Lever
Z-15GW255-B,
Z-15GW2A55-B5V
t = 1 (stainless steel lever)
26.2
4 dia. (plastic roller)
(With Terminal Protection Cover)
48.5R
OP FP
16.9
20.2
4.36
13.9
9.2
+0.075
–0.025
4.2
+0.075
+0.1
–0.05 dia.
4.2
–0.025 dia. hole
17.45±0.2
25.4±0.1 11.9
49.2
Unidirectional Short Hinge Roller Lever
Z-15GW227755-B,
Z-15GW2277A55-B5V
(With Terminal Protection Cover)
Operating direction
26.2
9.5 × 4 dia. (plastic roller)
t = 1
(stainless
steel lever)
31.9R
OP FP
34.1
max.
20.2 16.9
13.9
9.2
+0.075
4.2
–0.025
+0.075
–0.025 dia. hole
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Reverse Hinge Lever
Note: The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin
plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers
are normally pressed.
t = 1
(stainless
steel lever)
18.65
Z-15GM55-B
4.9
56R
4
max.
20.2
FP
OP
17.4
13.9
4.2
+0.075
–0.025
9.2
4.2
+0.075
–0.025 dia. hole
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Reverse Short Hinge Roller Lever
Note: The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin
plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers
are normally pressed.
Z-15GM2255-B
18.65
t = 1 (stainless steel lever)
9.5 × 4 dia. (plastic roller)
18.5R
4 max.
20.2
FP
OP
13.9
17.4
9.2
+0.075
–0.025
4.2
+0.075
–0.025 dia. hole
+0.1
–0.05 dia.
4.2
4.36
17.45±0.2
25.4±0.1 11.9
49.2
40
Z
Z
Reverse Hinge Roller Lever
Note: The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin
plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers
are normally pressed.
Z-15GM255-B
t = 1 (stainless steel lever)
18.65
9.5 × 4 dia. (plastic roller)
4 max.
FP
OP
20.2 17.4
13.9
+0.075
–0.025
9.2
4.2
+0.075
–0.025 dia. hole
+0.1
–0.05 dia.
4.2
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Flexible Rod (Coil Spring)
Z-15GNJ55-B
See note 1
PT
6.1 dia.
3.2 dia.
Optimum
operating
range
Nylon rod
30
38
(see note 2)
(111.3)
Rubber cap
43.4
12 dia.
23.3±0.25
(13.6)
+0.075
–0.025 dia. hole
4.2
16.3
+0.075
–0.025
4.2
9.2
+0.1
–0.05 dia.
4.36
25.4±0.1 11.9
17.45±0.2
49.2
Note: 1. The coil spring may be operated from any direction except axial direction (↓).
2. Be sure to use the dog or cam within 30 mm form the top end of the stainless wire.
(Avoid use within 80 mm from the mounting hole.)
Flexible Rod (Steel Wire)
Z-15HNJS55-B
See note 1
PT
Optimum
operating
range
30
(see note 2)
100±4
M3 x 4 hexagon
socket head screw
(130.1)
(22)
Rubber cap
23.3±0.25
(13.8)
16.3
+0.075
–0.025
4.2
+0.1
–0.05 dia.
4.36
17.45±0.2
25.4±0.1 11.9
49.2
Note: 1. The coil spring may be operated from any direction except axial direction (↓).
2. Be sure to use the dog or cam within 30 mm form the top end of the stainless wire.
(Avoid use within 100 mm from the mounting hole.)
41
Z
Z
Maintained Contact Models
Pin Plunger
Z-15ER
2.3 dia.
PT
+0.075
23.3±0.25
2.3R (stainless steel plunger)
4.2
–0.025 dia. hole
Reset operating
position 7.1 min.
OP
21.4
6.4
+0.075
4.2
–0.025
+0.1
4.36
dia.
–0.05
14.3±0.3 11.9
Reset free position
9.5 max.
25.4±0.1
17.45±0.2
49.2
Slim Spring Plunger
Z-15ESR
23.3±0.25
5.2 dia.
PT
4 dia.
See
note
Reset operating
position 7.1 min.
9 dia.
21.4
6.4
+0.075
–0.025
4.2
+0.1
–0.05
4.36
dia.
6.4 dia.
Reset button
(plastic
plunger)
11.9
Reset free position
9.5 max.
14.3±0.3
25.4±0.1
49.2
17.45±0.2
Note: Stainless steel plunger
(flat, 1R chamfered)
Hinge Lever
Z-15EWR
t = 1
63.5R
26.2
4.9
Reset operating
position 7.1 min.
FP
20.2
16.9
OP
13.9
+0.075
–0.025
6.4
4.2
+0.1
4.36
dia.
–0.05
6.4 dia.
11.9
14.3±0.3
25.4±0.1
49.2
Reset free position
9.5 max.
Reset button
(plastic
17.45±0.2
plunger)
Kind of Terminals
Basic (General-purpose) Models
Split Contact Models
Screw Terminals (Y-B)
Screw Terminals (-B)
Solder Terminal (-A)
(see note 1)
5.6
6.4
9.2
11.9
20
20
11.9
2
23
2
17.1
55 dia.
ews
ashers)
(see note 2)
x 55 dia.
rews
(with cup washers)
(see note 2)
49.2
49.2
Note: 1. The suffix “-A” is not used.
2. Add the suffix “-B” for models with toothed washers.
3. With reverse action models (Z-15GM and Z-10FM), the positions
of NO and NC terminals are reversed.
42
Z
Z
Basic (Drip-proof) Models
Without Drip-proof Terminal
Protection Cover
With Drip-proof Terminal
Protection Cover
6SR (stainless
steel plunger)
23.3±0.25
3.9 dia.
PT
+0.075
–0.025 dia. hole
4.2
OP
14.7
(11)
9.2
19.2
+0.075
–0.025
4.2
20
20
17.45±0.2
+0.1
–0.05 dia.
4.36
17.45±0.2
11.9
4 x 55 dia.
screws
(with cup washers)
(see note 1)
25.4±0.1 11.9
(28.8)
49.2
52.8
Note: 1. Add the suffix “-B” for models with toothed washers.
2. With reverse action model (Z-15GM), the positions of NO and NC terminals are reversed.
Molded Terminal
a
a: VSF cord: 12 mm
VCT cord: 19 mm
Molded resin
Ordering Information
Z-j55-Mjjj jM
1
2
3
4
5
1. Drip-proof
Type
5. Length of Lead Outlets
0.5:
1:
0.5 m
1 m
2. Lead Outlets
None: VSF
2:
2 m
19:
VCT
3:
3 m
3. Directions of Lead Outlets
Refer to the following diagrams.
4. Contacts
None: SPDT
2:
3:
SPST-NC
SPST-NO
43
Z
Z
Directions of Lead Outlets
The following models are Z15GW2255-type models with molded terminals with VSFs.
L: Left-hand
F: Forward
R: Right-hand
Z-15GW2255-ML
Z-15GW2255-MF
Z-15GW2255-MR
H: Rearward
D: Underside
Z-15GW2255-MH
Z-15GW2255-MD
Lead Wire Specifications
Lead wire
Nominal cross-sectional
Finished outer diameter
(mm)
Connection to terminal
Length (m)
0.5, 1, 2, 3
2
area (mm
)
Black: COM
White: NO
Red: NC
VSF (single-core, vinyl
cord)
1.25
Approx. 3.1 dia.
VCT (vinyl-insulated
cable)
Two-core: approx. 9.6 dia.
Three-core: approx. 10.5 dia.
Note: No models with molded terminals are approved by UL, CSA, or SEV
.
Contact Form
SPDT
SPST-NC
SPST-NO
COM
NO
COM
NO
NC
COM
(Black)
NC
(Red)
(Black) (White)
(Black) (White) (Red)
Note: 1. Colors in parentheses are the colors of the lead wire insulation covers of the models.
2. With reverse-action model (Z-15GM), the position of NO and NC terminals are reversed.
44
Z
Z
Precautions
Mounting
Wiring
Use M4 mounting screws with plain washers or spring washers to
Models with Drip-proof Terminal Cover (Z-j-B5V)
mount the switch. Tighten the screws at a torque of 1.18 to 1.47 N
(12 to 15 kgf S cm).
S
To attach the protective cover to the case, hold the cover in almost
parallel to the case and then push it to the case. If the cover is
pushed diagonally, the rubber packing may slip off, degrading the
sealability of the switch.
m
Mounting Dimensions
Two, 4.3 dia. mounting holes or
M4 screw holes
Terminal with
spring washe
25.4 ± 0.1
Solder the lead to the terminal by applying a soldering iron rated at
60 W max. quickly (within 5 seconds). Applying a soldering iron for
Rubb
too long a time or using one that is rated at more than 60 W may de
-
grade the switch characteristics.
Refer to the following for appropriate tightening torque for each
type.
Split contact models (excluding the Z-10FY-B): 0.78 to 1.18 N S m (8
to 12 kgf S cm)
Z-10FY-B split contact model: 0.49 to 0.78 N
S m (5 to 8 kgf S cm)
Panel Mount Switch (Z-15jQj, Z-01jQj)
When mounting a panel mount switch to a panel, tighten the hexa
gon nut of the actuator at a torque of 50 kg S cm (4.9 N) or less.
-
Use solder terminals having the following dimensions to connect
leads to the terminals. Tighten the screws of terminals at a torque of
8
to 12 kg S cm (0.78 to 1.18 N S m).
When mounting a panel mount switch on its side, remove the hexa
gon nut from the actuator and carefully adjust the dog angle and op
erating speed because too large a dog angle or too high an operat
-
-
-
4.3 dia.
ing speed may damage the switch. Especially be careful not to apply
an impulsive force to the actuator when operating it. By the same
token, too high an operating speed and too long an overtravel may
8
damage a panel mount switch with a roller pin plunger
When side-mounting a panel-mounting switch with a pin plunger, re
move the hexagonal nut from the actuator
.
20 max.
-
.
A
cable 8.5 to 10.5 mm in diameter can be used as the sealing rub-
Panel Mounting
Plunger Model
Panel Mounting
Roller Plunger
Model
ber of the lead outlet of the switch. A two-core or three-core VCT
cable having a cross-sectional area of 1.25 mm is especially suit
able for this.
2
-
Use M4 small screws with spring washer to fix the terminals.
12.5 dia.
12.5 dia.
Others
Do not apply an excessive force to the mounting bracket with a
5
screwdriver or a similar object when attaching or detaching the pro
tective cover; otherwise, the cover will be deformed.
-
13
High-sensitivity Switch (Z-15H)
Driver
When using the switch in a DC circuit, be sure to provide an arc sup
pressor as well because the small contact gap of the switch may re
sult in contact troubles.
-
-
In an application where a high repeat accuracy is required, limit the
current that flows through the switch to within 0.1 A. Also, use a relay
to control a high-capacity load if the switch is connected to such a
load. (In this case, the exciting current of the relay coil is the load of
the switch.)
This terminal protection cover cannot be used with models whose
model number does not have the prefix “-B5V”.
Do not apply a force of 2 kg or higher to the pin plunger
Exercise care that the environment conditions such as temperature
and humidity do not change abruptly
.
Drip-proof Switch (Z-j55)
The switch is not perfectly oil-tight; so do not dip it in oil or water
.
.
The rubber boots are made from weather-resistive chloroprene rub
ber.
-
-
Microload Switch
Do not use basic switches in places with radical changes in temper
ature.
Do not use a basic switch with standard contacts to switch minute
loads, or the loads may not be switched properly due to improper
contact. Instead, use a basic switch with contacts appropriate for
minute loads. The following is the optimum switching range of the
Z-01H, which is suitable for switching minute loads.
Maintained Contact Switch (Z-15EjR)
Apply a force to the reset button from right angles to the bottom plate
of the switch. Use an appropriate actuator when the reset button is
operated by a cam or dog.
Recommended load range of the Z-01H: 1 to 100 mA at 5 to 30 VDC
The above range may vary with the environmental conditions for the
Z-01H. Contact your OMRON representative for details.
45
Z
Z
Split Contact Switch (Z-10FjY)
Flexible Rod Switch (Z-15jNJj55, Drip-proof)
When the rod is fully swung, the switch may operate when the lever
The applicable current varies depending on how the contacts are
used. If the switch is connected in series, the switch can endure a
current 1.5 to 2 times higher than the current that can be applied in
parallel connection.
returns, causing chattering. Use a circuit that compensates for chat
-
tering wherever possible.
Do not switch the rod to the fullest extent when the switch is to break
a power circuit because such a practice may cause metal deposi-
tion to occur between the mating contacts of the switch.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. B01-E1-10
46
相关型号:
©2020 ICPDF网 联系我们和版权申明