FLUKE-125B [FLUKE]
ScopeMeter® Hand-Held Oscilloscopes Dual-input digital oscilloscope and multimeter;型号: | FLUKE-125B |
厂家: | Fluke Corporation |
描述: | ScopeMeter® Hand-Held Oscilloscopes Dual-input digital oscilloscope and multimeter |
文件: | 总11页 (文件大小:2887K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TECHNICAL DATA
Fluke 120B Series Industrial
®
ScopeMeter Hand-Held Oscilloscopes
Simplified testing, more insight and faster
electro-mechanical troubleshooting
The compact ScopeMeter® 120B Series, is the rugged oscilloscope
solution for industrial electrical and electro-mechanical equip-
ment troubleshooting and maintenance applications. It’s a truly
integrated test tool, with oscilloscope, multimeter and high-speed
recorder in one easy-to-use instrument. The ScopeMeter 120B
Series also integrates with Fluke Connect® mobile app and
FlukeView® for ScopeMeter software to enable further collabora-
tion, data analysis and archiving of critical test information.
The 120B Series Industrial ScopeMeter Test Tools include innova-
tive functions designed to help technicians troubleshoot faster and
get the answers they need to keep their systems up and running.
Display waveforms with Connect and View™ trigger and setup
technology and automatically view related numerical measure-
ments using Fluke IntellaSet™ technology, all without making
manual measurement adjustments. With Recorder Event Detect
capabilities, elusive intermittent events are captured and logged
for easy viewing and analysis.
• Dual-input digital oscilloscope and multimeter
• 40 MHz or 20 MHz oscilloscope bandwidth
• Two 5,000-count true-rms digital multimeters
• Connect-and-View™ trigger simplicity for hands-off operation
• IntellaSet™ technology automatically and intelligently adjusts
numerical readout based on the measured signal
• Dual-input waveform and meter reading recorder for
KEY MEASUREMENTS
Voltage, current and power waveforms
with numerical values including harmonics,
resistance, diode, continuity and
capacitance measurements.
trending data over extended periods
• Recorder Event Detect captures elusive intermittent signals on
repetitive waveforms up to 4 kHz
AUTOMATICALLY CAPTURE, VIEW AND
ANALYZE COMPLEX WAVEFORMS
Fluke Connect and View™ triggering
automatically displays waveforms without
having to adjust amplitude, timebase and
trigger settings, while Intellaset™ technology
analyzes the signal and automatically
displays critical numerical readings, making
troubleshooting faster than ever.
FLUKE CONNECT® COMPATIBLE*
View data locally on the instrument,
or via Fluke Connect mobile app.
*Not all models are available in all countries.
Check with your local Fluke representative.
• Shielded test leads for oscilloscope, resistance and
continuity measurements
• Resistance, continuity, diode and capacitance meter
measurements
• Power measurements (W, VA, VAR, PF, DPF, Hz)
• Voltage, current and power harmonics
• Check Industrial networks with BusHealth physical layer tests
against defined reference levels
• Save or recall data and instrument setups
• Store instrument setups defined by a test sequence for routine
maintenance or most often used test procedures.
• External optically isolated USB interface to transfer, archive
and analyze scope or meter data
• Optional WiFi adapter connected to internal USB port to
wirelessly transfer information to the PC, laptop or
Fluke Connect® mobile app*
• FlukeView® ScopeMeter® Software for Windows®
• Rugged design to withstand 3g Vibration, 30g shock, and
rated IP51 according to EN/IEC60529
• Highest safety rating in the industry: safety rated for
CAT IV 600 V
• Li-Ion rechargeable battery, seven-hours operation (with
four-hour charge time)
*Not all models are available in all countries. Check with
your local Fluke representative.
™
Connect-and-View™
IntellaSet /AutoReading
triggering for an instant,
The Auto Readings function
with Fluke IntellaSet™ technol-
ogy uses proprietary algorithms
to intelligently analyze the
measured waveform and auto-
matically displays the most
appropriate numerical measure-
ments on screen, so you can get
the data you need easier than
ever before. As an example,
when the measured wave-
form is a line voltage signal,
the Vrms and Hz readings
stable display
Oscilloscope users know how
difficult triggering can be.
Using the wrong settings can
lead to unstable waveform
captures, and sometimes the
wrong measurement data.
Fluke’s unique Connect-and-
View™ triggering technology
recognizes signal patterns, and
automatically sets up the correct
triggering to provide a stable,
reliable and repeatable display.
Connect-and-View™ triggering
is designed to work with virtu-
ally any signal, including motor
drives and control signals—
without adjusting parameters,
or even touching a button.
Signal changes are instantly
recognized and settings are
automatically adjusted, provid-
ing a stable display even when
measuring multiple test points
in quick succession.
are automatically displayed,
whereas if the measured
waveform is a square wave, the
Vpeak-peak and Hz readings
are automatically displayed.
Using IntellaSet™ technology
in conjunction with Connect-
and-View™ automatic triggering
you can be sure you’re seeing
not only the correct wave-
form, but the appropriate
Fluke Connect-and-View™ triggering
with Auto Reading function using Fluke
IntellaSet™ technology gives you quick
access to the data you need.
numerical reading as well. All
without touching a button.
2 Fluke Corporation Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
Industrial equipment needs a reliable power supply to
operate properly, use the dual input to obtain key power
measurements.
For single phase or 3-phase balanced systems, the dual inputs
of the Industrial ScopeMeter® 120B Series can measure ac+dc
rms voltage on channel A and ac+dc rms current on channel
B. The Fluke 125B can then calculate; frequency, phase angle,
active power (kW), reactive power (VA or var), power factor (PF)
or displacement power factor (DPF) and can also calculate the
power values for a 3-phase system where all phases have equal
voltage and currents. This applies to both balanced system and
resistive loads.
Easily obtain key power characteristics to validate a system
power.
Harmonics measurements
Harmonics are periodic distortions of voltage,
current, or power sine waves. Harmonics in
power distribution systems are often caused
by non-linear loads such as switched mode
dc power supplies and adjustable speed motor
drives. Harmonics can cause transformers,
conductors, and motors to overheat. In the
Harmonics function, the Test Tool measures
harmonics to the 51st. Related data such as dc
components, THD (Total Harmonic Distortion),
and K factor are measured to provide a com-
plete insight in to the electrical state of health
of your loads.
®
®
FlukeView ScopeMeter
®
Software for Windows
Get more out of your ScopeMeter
120B with FlukeView® Software:
• Store instrument’s screen
copies on the PC, in color
Harmonic spectrum overview with cursors
to measure the distortion as a percentage
of the fundamental.
• Copy screen images into your
reports and documentation
• Capture and store waveform
data from your ScopeMeter
on your PC
• Create and archive wave-
form references for easy
comparison
• Copy waveform data into
your spreadsheet for detailed
analysis
One test lead to measure multiple
electrical parameters
High frequency waveform, meter, capacitance and
resistance measurements as well as continuity
checks are all covered by single set of shielded
test leads. No time is wasted finding or swapping
leads.
• Use cursors for parameter
measurement
• Add user text to instrument
setups and send them to the
instrument for operator refer-
ence and instructions
A single test tool measures volts, ohms,
amps or capacitance, in addition to
displaying waveforms.
3 Fluke Corporation Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
Quickly step through recorded events
to identify and troubleshoot intermittent
faults.
Quickly understand industrial field bus
signal physical layer analog characteristics.
Fluke Connect mobile app
compatibility
Use the comprehensive
Industrial Bus Health Test
verifies electrical signal
recorder modes to help find
intermittent faults with ease quality on industrial buses
Automated industrial machinery
is harder than ever to trouble
shoot. It’s not enough to just
know where you have to test,
you also have to know what to
look for—and that can be hard
without baseline measurement
data or access to subject matter
experts. The Fluke Connect®
Assets wireless system of
software and wireless test tools
enables technicians to reduce
maintenance costs and increase
uptime with accurate equip-
ment records and maintenance
data that is easy to interpret,
and share. Compare and
The toughest faults to find are
those that happen only once
in a while—intermittent events.
They can be caused by bad
connections, dust, dirt, corro-
sion or simply broken wiring
or connectors. Other factors,
like line outages and sags or
the starting and stopping of
a motor, can also cause inter-
mittent events resulting in
Bus Health Test analyzes the
electrical signals on the indus-
trial bus or network and gives
a clear “Good”, “Weak” or “Bad”
indication mark for each of the
relevant parameters, presented
next to the actual measurement
value. Measured values are
compared to standard values
based on the selected bus types
(CAN-bus, Profi-bus, Foundation
Field, RS-232 and many more),
or, unique reference values
equipment shutdowns. When
these events happen, you may
not be around to see it. But,
your Fluke ScopeMeter® Test
Tool will. You can either plot the
minimum and maximum peak
measurement values or record
the waveform trace. And, with
expandable micro SD memory,
recording sessions can be done
for up to 14 days. This recorder
is even more powerful with
the addition of Recorder Event
Detect, which makes detect-
ing and logging intermittent
can be set if different toler-
ances are required. The Fluke
125B can validate the quality
of the electrical signals as soon
as they are passed along the
network, without looking at the
data content. Additionally, the
125B checks the signal levels
and speed, transition times and
distortion, and compares these
to the appropriate standards
to help you find errors such as
improper cable connections, bad
contrast test point measure-
ment data and trends so you
can better understand signal
characteristics and changes
over time. And, by storing
maintenance data on the Fluke
™
Cloud you can enable team
members to access it from
wherever and whenever they
need to so you can get advice
or approvals in the field and
get your systems up and run-
ning faster than ever before.
faults easier than ever. Just set a contacts, incorrect grounding or
threshold on a meter reading or
scope trace and deviations are
tagged as unique events. You no
longer need to search through
masses of data to pinpoint faults,
and can quickly step from one
tagged event to the next, while
still having access to the full
data set.
improper terminators.
4 Fluke Corporation Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
Specifications
Oscilloscope mode
Vertical
Frequency response - dc coupled without probes and test leads (with BB120)
123B: dc to 20 MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)
with STL120-IV 1:1 shielded test leads
with VP41 10:1 Probe
DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)
123B: dc to 20MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)
Frequency response - ac coupled
(lf roll off)
without probes and test leads
with STL120-IV 1:1 shielded test leads
with VP41 10:1 Probe
<10 Hz (-3 dB)
<10 Hz (-3 dB)
<10 Hz (-3 dB)
Rise time, excluding probes,
test leads
123B <17.5 ns
124B and 125B <8.75 ns
Input impedance
without probes and test leads
with BB120
1 MΩ//20 pF
1 MΩ//24 pF
1 MΩ//230 pF
5 MΩ//15.5 pF
with STL120-IV 1:1 shielded test leads
with VP41 10:1 Probe
5 mV to 200 V/div
Sensitivity
Analog bandwidth limiter
Display modes
10 kHz
A, -A, B, -B
Max. input voltage A and B
direct, with test leads, or with VP41 Probe
with BB120
600 Vrms CAT IV, 750 Vrms maximum voltage.
600 Vrms
Max. floating voltage, from any
terminal to ground
600 Vrms CAT IV, 750 Vrms up to 400Hz
Horizontal
Scope modes
Ranges (Normal)
Normal, Single, Roll
Equivalent sampling
123B: 20 ns to 500 ns/div,
124B and 125B: 10 ns to 500 ns/div
1 μs to 5 s/div
Real time sampling
Single (real time)
1 μs to 5 s/div
Roll (real time)
1s to 60 s/div
Sampling rate (for both channels
simultaneously)
Equivalent sampling (repetitive signals)
Real time sampling 1 μs to 60 s/div
up to 4 GS/s
40 MS/s
Trigger
Screen update
Source
Free run, on trigger
A, B
Sensitivity A and B
@ DC to 5 MHz
@ 40 MHz
0.5 divisions or 5 mV
123B: 4 divisions
124B and 125B: 1.5 divisions
123B: N/A
@ 60 MHz
124B and 125B: 4 divisions
Slope
Positive, negative
Normal
Advanced scope functions
Display modes
Captures up to 25 ns glitches and displays
analog-like persistence waveform.
Smooth
Suppresses noise from a waveform.
Glitch off
Envelope
Does not capture glitches between samples
Records and displays the minimum and
maximum of waveforms over time.
Auto set (Connect-and-View™)
Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and
hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.
5 Fluke Corporation Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
Dual input meter
The accuracy of all measurements is within (% of reading + number of counts) from 18 °C to 28 °C.
Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe
uncertainty +1 %. More than one waveform period must be visible on the screen.
Input A and input B
DC voltage (VDC)
Ranges
500 mV, 5 V, 50 V, 500 V, 750 V
(0.5 % +5 counts)
Accuracy
Common mode rejection (CMRR)
Full scale reading
>100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
5000 counts
True-rms voltages (V ac and V ac+dc)
Ranges
500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5 % to 100 % of
range (DC coupled)
DC to 60 Hz (V ac+dc)
1 Hz to 60 Hz (V ac)
60 Hz to 20 kHz
(1 % +10 counts)
(1 % +10 counts)
(2.5 % +15 counts)
Accuracy for 5 % to 100 % of
range (AC or dc coupled)
DC rejection (only VAC)
>50 dB
Common mode rejection (CMRR)
>100 dB @ dc
>60 dB @ 50, 60, or 400 Hz
Full scale reading
Peak
5000 counts, reading is independent of any signal crest factor.
Modes
Max peak, Min peak, or pk-to-pk
500 mV, 5 V, 50 V, 500 V, 2200 V
Ranges
Accuracy
Accuracy Max peak or Min peak
Accuracy Peak-to-Peak
500 counts
5 % of full scale
10 % of full scale
Full scale reading
Frequency (Hz)
Ranges
123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz
124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
15 Hz (1 Hz) to 50 MHz in continuous autoset
Frequency range
Accuracy @1 Hz to 1 MHz
Full scale reading
RPM
(0.5 % +2 counts)
10 000 counts
Max reading
50.00 kRPM
Accuracy
(0.5 % +2 counts)
Duty cycle (PULSE)
Range
2 % to 98 %
Frequency range
Pulse width (PULSE)
Frequency range
15 Hz (1 Hz) to 30 MHz in continuous autoset
15 Hz (1 Hz) to 30 MHz in continuous autoset
1000 counts
Full scale reading
Amperes (AMP)
With current clamp
Ranges
same as V dc, V ac, V ac+dc, or PEAK
Scale factors
0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A,
1 V/A, 10 mV/mA
Accuracy
same as V dc, V ac, V ac+dc, or PEAK
(add current clamp uncertainty)
6 Fluke Corporation Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
Temperature (TEMP) with optional temperature probe
Range
200 °C/div (200 °F/div)
Scale factor
Accuracy
1 mV/°C and 1 mV/°F
as V dc (add temp. probe uncertainty)
Decibel (dB)
0 dBV
1 V
0 dBm (600 Ω /50 Ω)
dB on
1 mW referenced to 600 Ω or 50 Ω
V dc, V ac, or Vac+dc
1000 counts
Full scale reading
Crest factor (CREST)
Range
1 to 10
Full scale reading
Phase
90 Counts
Modes
A to B, B to A
0 to 359 degrees
1 degree
Range
Resolution
Power (125B only)
Configurations
1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET
mode only)
Power factor (PF)
Watt
Ratio between watts and VA range - 0.00 to 1.00
RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)
Full scale reading
Vrms x Arms
999 counts
999 counts
999 counts
VA
Full scale reading
√((VA)2-W2)
VA reactive (var)
Full scale reading
Vpwm
Purpose
Principle
to measure on pulse width modulated signals, like motor drive inverter outputs
readings show the effective voltage based on the average value of samples over a whole number of
periods of the fundamental frequency
Accuracy
as Vrms for sinewave signals
Input A to common
Ohm (Ω)
Ranges
123B and 124B
500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
125B
50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy
(0.6 % + 5 counts) 50 Ω (2 % + 20 counts)
50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts
0.5 mA to 50 nA, decreases with increasing ranges
<4 V
Full scale reading
Measurement current
Open circuit voltage
Continuity (Cont)
Beep
<(30 Ω 5 Ω) in 50 Ω range
Measurement current
Detection of shorts of
Diode
0.5 mA
≥1 ms
Measurement voltage
@0.5 mA
>2.8 V
<4 V
@open circuit
0.5 mA
Measurement current
Polarity
+ on input A, - on COM
7 Fluke Corporation Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
Capacitance (CAP)
Ranges
50 nF, 500 nF, 5 μF, 50 μF, 500 μF
5000 counts
Full scale reading
Measurement current
Advanced meter functions
Zero Set
500 nA to 0.5 mA, increases with increasing ranges
Set actual value to reference
AutoHold (on A)
Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main
meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Fixed decimal point
Cursor Readout (124B and 125B)
Sources
Activated by using attenuation keys.
A, B
Single vertical line
Average, min and max readout
Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
Harmonics values in POWER QUALITY mode.
Dual vertical lines
Peak-peak, time distance and reciprocal time distance readout
Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
High, low and peak-peak readout
Dual horizontal lines
Rise or fall time
Transition time, 0 %-level and 100 %-level readout (manual or auto leveling; auto leveling only
possible in single channel mode)
Accuracy
As oscilloscope accuracy
Recorder
The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The
information is stored on internal memory or on optional SD card (with the 125B or 124B).
The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a
waveform recorder display that plots all the captured samples.
Meter readings
Measurement Speed
Maximum 2 measurements/s
2 M readings for 1 channel
2 weeks
Record Size (min, max, average)
Recorded Time Span
Maximum number of events
Waveform record
1024
Maximum sample rate
Size Internal memory
400 K sample/s
400 M samples Recorded Time
15 minutes at 500 μs/div
1.5 G samples
Span internal memory
Record Size SD card
11 hours at 20 ms/div
14 days at 20 ms/div
Recorded Time Span SD card
Maximum number of events
11 hours at 500 μs/div
64
8 Fluke Corporation Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
Power Quality (125B only)
Readings
Watt, VA, var, PF, DPF, Hz
250 W to 250 MW, 625 MW, 1.56 GW
when selected: total (%r)
when selected: fundamental (%f)
0.00 to 1.00
Watt, VA, var ranges (auto)
(2 % + 6 counts)
(4 % + 4 counts)
DPF
PF
0.00 to 1.00, 0.04
Frequency range
Number of Harmonics
10.0 Hz to 15.0 kHz
40.0 Hz to 70.0 Hz
DC to 51
Readings / Cursor readings
(fundamental 40 Hz to 70 Hz)
V rms / A rms /Watt
each harmonic from fundamental maybe selected
for individual readings
Includes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)
Bus health tester (Fluke 125B only)
Type
Subtype
NEN-EN50295
ISO-11898
RS-422
RS-232
RS-485
H1
Protocol
AS-i
CAN
Interbus S
Modbus
EIA-422
RS-232/EIA-232
RS-485/EIA-485
61158 type 1, 31.25 kBit
EIA-485
Foundation Fieldbus
Profibus
DP
PA
61158 type 1
RS-232
EIA-232
EIA-485
RS-485
Miscellaneous
Display
Type
5.7-inch color active matrix TFT
640 x 480 pixels
Resolution
Waveform Display
Power
Vertical
10 div of 40 pixels
Horizontal
12 div of 40 pixels
External
via Power Adapter BC430
10 V DC to 21 V DC
Input voltage
Power consumption
Input connector
Internal
5 W typical
5 mm jack
via Battery Pack BP290
Rechargeable Li-Ion 10.8 V
7 hours with 50 % backlight brightness
Battery power
Operating time
Charging time
4 hours with test tool off,
7 hours with test tool on
Allowable ambient temp
0 to 40 °C (32 to 104 °F) during charging
Memory
Internal memory can store 20 data sets
(screen waveform and setup)
Micro SD card slot with optional SD card
(max size of 32 GB)
Mechanical
Size
259 mm x 132 mm x 55 mm
(10.2 in x5.2 in x 2.15 in)
Weight
1.4 kg (3.2 lb) including battery pack
9 Fluke Corporation Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
Interface
Optically isolated
USB to PC/laptop
Transfer screen copies (bitmaps), settings and
data
OC4USB optically isolated USB adapter/cable,
(optional), using FlukeView® software for
Windows®.
Optional WiFi adapter
Fast transfer of screen copies (bitmaps), settings
and data to PC/laptop, tablet, smartphone, etc.
A USB port is provided for attaching the WiFi
dongle. Do not use the USB port with a cable for
safety reasons.
Environmental
Environmental
Temperature
MIL-PRF-28800F, Class 2
Battery Operation
0 to 40 °C (32 to 104 °F)
0 to 50 °C (32 to 122 °F)
-20 to 60 °C (-4 to 140 °F)
noncondensing
95 %
Power Adapter Operation
Storage
Humidity (Operating)
@ 0 to 10 °C (32 to 50 °F)
@ 10 to 30 °C (50 to 86 °F)
@ 30 to 40 °C (86 to 104 °F)
@ 40 to 50 °C (104 to 122 °F)
@ -20 to 60 °C (-4 to 140 °F)
Operating at 3 km (10 000 feet)
Operating at 2 km (6 600 feet)
Storage
75 %
45 %
Storage
Altitude
noncondensing
CAT III 600 V
CAT IV 600 V
12 km (40 000 feet)
EMC electromagnetic
compatibility
International
IEC 61326-1: Industrial, CISPR 11:
Group 1, Class A
Korea (KCC)
USA (FCC)
Class A Equipment (Industrial Broadcasting &
Communication Equipment)
47 CFR 15 subpart B. This product is considered
an exempt device per clause 15.103.
Wireless radio with adapter
Frequency range
2412 MHz to 2462 MHz
<100 mW
Output power
Enclosure protection
Safety
IP51, ref: EN/IEC60529
General
IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
600 Vrms CAT IV for derating
600 Vrms for derating
Measurement
Max. input voltage input A and B
Direct on input or with leads
With Banana-to BNC Adapter BB120
Max. floating voltage from any terminal to ground 600 Vrms CAT IV, 750 Vrms up to 400 Hz
Fluke 123B
Fluke 124B
Fluke 125B
Functions
Full function dual input scope and meter
Oscilloscope bandwidth MHz
Meter and Scope Recorder
Scope cursor measurements
Power and harmonics measurements
Bus health
·
·
·
20
40
40
·
·
·
·
·
·
·
Included accessories
10:1 voltage probe
·
·
·
i400S AC Current Clamp
10 Fluke Corporation Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
Fluke 125B
Ordering information
Fluke-123B Industrial ScopeMeter® Hand Held
Oscilloscope (20 MHz)
Fluke-123B/S Industrial ScopeMeter® Hand Held
Oscilloscope (20 MHz)*
Fluke-124B Industrial ScopeMeter® Hand Held
Oscilloscope (40 MHz)
Fluke-124B/S Industrial ScopeMeter® Hand Held
Set up and sustain preventive maintenance practices with
ease to help you oversee your complex world with the Fluke
Oscilloscope (40MHz)*
Fluke-125B Industrial ScopeMeter® Hand Held
®
Connect system of software and over 40 wireless test tools.
Oscilloscope (40MHz)
• Maximize uptime and make confident maintenance decisions with data
Fluke-125B/S Industrial ScopeMeter® Hand Held
you can trust and trace.
Oscilloscope (40MHz)*
™
• Save measurements to the Fluke Cloud and associate with an asset so
your team can consult baseline, historical and current measurements
Includes: Li-Ion battery pack, charger/power
adapter, 2 shielded test leads with ground leads,
black test lead, red and blue hook clips, banana
to BNC adapter, and WiFi USB adapter**
from one location.
• Collaborate with ease by sharing your measurement data with team
members with ShareLive™ video calls and emails.
• Wireless one-step measurement transfer with AutoRecord™ measure-
ments eliminates transcription errors, clipboards, notebooks and multiple
spreadsheets.
*Fluke 120B/S versions also include soft carry case,
FlukeView™ for Windows® software, magnetic hanger,
and screen protector.
• Generate reports with multiple measurement types to provide status or
next step recommendations.
Find out more and take a free trial at: flukeconnect.com
Google and Android store images
**WiFi USB adapter NOT available in all countries. Check
with your local Fluke representative.
WiFi or cellular service is required to share data. Smart phone, wireless
service and data plan not included with purchase. First 5 GB of storage is
free. Phone support details can be viewed at fluke.com/phones.
STL120-IV Shielded Test Lead Set 600 V CAT IV
HC120-II Set of 2 hook clips
BB120-II Set of 2 banana to BNC adapter
VPS41 Voltage probe set 40MHz 600 V CAT IV
C120B Soft Carrying Case For 120B Series
SP120B Screen Protector For 120B Series
SCC120B Accessory Kit 120B Series
Download the app at:
OC4USB Fluke OC4USB USB Interface Cable
Smartphone wireless service and data
plan not included with purchase.
Fluke 80i 110s Fluke 80i-110s AC/DC Current
Clamp
Fluke i1000s Fluke i1000s AC Current Probe
Fluke i1010 Fluke i1010 AC/DC Current Clamp
Fluke i200s Fluke i200s AC Current Clamp
Fluke-i3000s Fluke i3000s AC Current Clamp
Fluke Connect is not available in all countries.
Fluke i3000s Flex 24 Fluke i3000s Flex-24 AC
Current Clamp, 610 mm (24 in.)
Fluke i3000s Flex 36 Fluke i3000s Flex-36 AC
Current Clamp, 915 mm (36 in.)
Fluke i30s Fluke i30s AC/DC Current Clamp
Fluke-i310s Fluke i310s Current Probe
Fluke i400s Fluke i400s AC Current Clamp
Fluke i410 Fluke i410 AC/DC Current Clamp
Fluke i5S Fluke i5S AC Current Clamp
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
Fluke. Keeping your world
®
up and running.
In Europe/M-East/Africa +31 (0) 40 2675
200 or
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
©2016 Fluke Corporation.
Modification of this document is not permitted
Specifications subject to change without notice.
without written permission from Fluke Corporation. Printed in U.S.A. 1/2016 6006986b-en
11 Fluke Corporation Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
相关型号:
FLUKE-125B/S
ScopeMeter® Hand-Held Oscilloscopes Dual-input digital oscilloscope and multimeter
FLUKE
©2020 ICPDF网 联系我们和版权申明