FT29F040B-55FD [FORCE]
4 Megabit (512 K x 8-Bit) CMOS 5.0 Volt-only, Uniform Sector Flash Memory;型号: | FT29F040B-55FD |
厂家: | Force Technologies |
描述: | 4 Megabit (512 K x 8-Bit) CMOS 5.0 Volt-only, Uniform Sector Flash Memory |
文件: | 总36页 (文件大小:3898K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FT29F040B
4 Megabit (512 K x 8-Bit)
CMOS 5.0 Volt-only, Uniform Sector Flash Memory
DISTINCTIVE CHARACTERISTICS
■ 5.0 V ± 10% for read and write operations
— Minimises system level power requirements
■ Embedded Algorithms
— Embedded Erase algorithm automatically
preprograms and erases the entire chip or any
combination of designated sectors
■ Manufactured on 0.32 µm process technology
— Compatible with 0.5 µm FT29F040 device
— Embedded Program algorithm automatically
writes and verifies bytes at specified addresses
■ High performance
— Access times as fast as 55 ns
■ Minimum 1,000,000 program/erase cycles per
sector guaranteed
■ Low power consumption
■ 20-year data retention at 125°C
— Reliable operation for the life of the system
■ Package options
— 20 mA typical active read current
— 30 mA typical program/erase current
— 1 µA typical standby current (standard access
time to active mode)
— 32-pin PLCC, TSOP, or PDIP
■ Flexible sector architecture
— 8 uniform sectors of 64 Kbytes each
— Any combination of sectors can be erased
— Supports full chip erase
■ Compatible with JEDEC standards
— Pinout and software compatible with
single-power-supply Flash standard
— Superior inadvertent write protection
— Sector protection:
■ Data# Polling and toggle bits
A hardware method of locking sectors to prevent
any program or erase operations within that sector
— Provides a software method of detecting
program or erase cycle completion
■ Erase Suspend/Erase Resume
— Suspends a sector erase operation to read data
from, or program data to, a non-erasing sector,
then resumes the erase operation
Rev 2
Page 1 of 36
FT29F040B
GENERAL DESCRIPTION
The FT29F040B is a 4 Mbit, 5.0 volt-only Flash mem-
ory organised as 524,288 Kbytes of 8 bits each. The
512 Kbytes of data are divided into eight sectors of 64
Kbytes each for flexible erase capability. The 8 bits of
data appear on DQ0–DQ7. The FT29F040B is offered
in 32-pin PLCC, TSOP, and PDIP packages. This device
is designed to be programmed in-system with the stan-
matically times the program pulse widths and verifies
proper cell margin.
Device erasure occurs by executing the erase com-
mand sequence. This initiates the Embedded Erase
algorithm—an internal algorithm that automatically
preprograms the array (if it is not already programmed)
before executing the erase operation. During erase, the
device automatically times the erase pulse widths and
verifies proper cell margin.
dard system 5.0 volt V supply. A 12.0 volt V is not
CC
PP
required for write or erase operations. The device can
also be programmed in standard EPROM programmers.
The host system can detect whether a program or
erase operation is complete by reading the DQ7 (Data#
Polling) and DQ6 (toggle) status bits. After a program
or erase cycle has been completed, the device is ready
to read array data or accept another command.
This device is manufactured using 0.32 µm pro-
cess technology, and offers all the features and
benefits of the FT29F040, which was manufactured
using 0.5 µm process technology. In addtion, the
FT29F040B has a second toggle bit, DQ2, and also of-
fers the ability to program in the Erase Suspend mode.
The sector erase architecture allows memory sectors
to be erased and reprogrammed without affecting the
data contents of other sectors. The device is fully
erased when shipped from the factory.
The standard FT29F040B offers access times of 55,
70, 90, 120, and 150 ns, allowing high-speed micropro-
cessors to operate without wait states. To eliminate bus
contention the device has separate chip enable (CE#),
write enable (WE#) and output enable (OE#) controls.
Hardware data protection measures include a low
V
detector that automatically inhibits write opera-
CC
tions during power transitions. The hardware sector
protection feature disables both program and erase
operations in any combination of the sectors of mem-
ory. This can be achieved via programming equipment.
The device requires only a single 5.0 volt power sup-
ply for both read and write functions. Internally
generated and regulated voltages are provided for the
program and erase operations.
The Erase Suspend feature enables the user to put
erase on hold for any period of time to read data from,
or program data to, any sector that is not selected for
erasure. True background erase can thus be achieved.
The device is entirely command set compatible with the
JEDEC single-power-supply Flash standard. Com-
mands are written to the command register using
standard microprocessor write timings. Register con-
tents serve as input to an internal state-machine that
controls the erase and programming circuitry. Write cy-
cles also internally latch addresses and data needed
for the programming and erase operations. Reading
data out of the device is similar to reading from other
Flash or EPROM devices.
The system can place the device into the standby mode.
Power consumption is greatly reduced in this mode.
Our Flash technology combines years of Flash
memory manufacturing experience to produce the
highest levels of quality, reliability and cost effective-
ness. The device electrically erases all bits within a
sector simultaneously via Fowler-Nordheim tunneling.
The data is programmed using hot electron injection.
Device programming occurs by executing the program
command sequence. This initiates the Embedded
Program algorithm—an internal algorithm that auto-
Rev 2
Page 2 of 36
FT29F040B
PRODUCT SELECTOR GUIDE
Family Part Number
FT29F040B
V
V
= 5.0 V ± 5%
= 5.0 V ± 10%
-55
N/A
55
N/A
-70
70
N/A
-90
90
N/A
-120
120
120
50
N/A
-150
150
150
55
CC
CC
Speed Option
Max access time, ns (t
)
ACC
Max CE# access time, ns (t
)
55
70
90
CE
Max OE# access time, ns (t
)
25
30
35
OE
Note: See the “AC Characteristics” section for more information.
BLOCK DIAGRAM
DQ0–DQ7
V
V
CC
Input/Output
Buffers
SS
Erase Voltage
Generator
State
Control
WE#
Command
Register
PGM Voltage
Generator
Chip Enable
Output Enable
Logic
Data Latch
STB
CE#
OE#
Y-Decoder
Y-Gating
STB
V
Detector
Timer
CC
X-Decoder
Cell Matrix
A0–A18
Rev 2
Page 3 of 36
FT29F040B
CONNECTION DIAGRAMS
A18
A16
A15
A12
A7
1
2
3
4
5
6
7
8
9
32
V
CC
31 WE#
30 A17
29 A14
28 A13
27 A8
4
3
2
1 32 31 30
A7
A6
5
29
28
27
26
25
24
23
22
21
A14
A13
A8
6
A6
A5
7
A5
26 A9
A4
8
A9
A4
25 A11
24 OE#
23 A10
22 CE#
21 DQ7
20 DQ6
19 DQ5
18 DQ4
17 DQ3
PDIP
A3
9
A11
OE#
A10
CE#
DQ7
A3
PLCC
A2
10
11
12
13
A2 10
A1 11
A1
A0
A0 12
DQ0
DQ0 13
DQ1 14
DQ2 15
14 15 16 17 18 19 20
V
16
SS
A11
A9
A8
1
2
3
4
5
6
7
8
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
OE#
A10
CE#
DQ7
DQ6
DQ5
DQ4
DQ3
VSS
DQ2
DQ1
DQ0
A0
A13
A14
A17
WE#
VCC
A18
A16
A15
A12
A7
32-Pin Standard TSOP
9
10
11
12
13
14
15
16
A6
A5
A4
A1
A2
A3
OE#
A10
CE#
DQ7
DQ6
DQ5
DQ4
DQ3
VSS
DQ2
DQ1
DQ0
A0
1
2
3
4
5
6
7
8
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
A11
A9
A8
A13
A14
A17
WE#
VCC
A18
A16
A15
A12
A7
32-Pin Reverse TSOP
9
10
11
12
13
14
15
16
A1
A2
A3
A6
A5
A4
Rev 2
Page 4 of 36
FT29F040B
PIN CONFIGURATION
LOGIC SYMBOL
A0–A18
=
Address Inputs
DQ0–DQ7 = Data Input/Output
19
CE#
WE#
OE#
=
=
=
=
=
Chip Enable
8
A0–A18
Write Enable
Output Enable
Device Ground
DQ0–DQ7
CE#
OE#
V
V
SS
CC
+5.0 V single power supply
(see Product Selector Guide for
device speed ratings and voltage
supply tolerances)
WE#
Rev 2
Page 5 of 36
FT29F040B
ORDERING INFORMATION
-
FT29F040B
-XX
X
X
TEMPERATURE RANGE
C
=
=
=
=
=
=
Commercial (0°C to +70°C)
Industrial (–40°C to +85°C)
Extended (–55°C to +125°C)
Commercial (0°C to +70°C) for Pb-free Package
Industrial (-40°C to +85°C) for Pb-free Package
Extended (-55°C to +125°C) for Pb-free Package
I
E
D
F
K
PACKAGE TYPE
P
=
=
=
32-Pin Plastic DIP (FTP 032)
J
32-Pin Rectangular Plastic Leaded Chip Carrier (FTJ 032)
E
32-Pin Thin Small Outline Package (TSOP) Standard Pinout (FTE 032)
F
K
=
=
32-Pin Thin Small Outline Package (TSOP) Reverse Pinout (FTF032)
32 Lead Cerquad "K" (CQ032)
SPEED OPTION
See Product Selector Guide and Valid Combinations
DEVICE NUMBER/DESCRIPTION
FT29F040B
4 Megabit (512 K x 8-Bit) CMOS 5.0 Volt-only Sector Erase Flash Memory
5.0 V Read, Program, and Erase
Valid Combinations
V
Voltage
CC
FT29F040B-55
JC, JI, JE, JD, JF, JK
EC, ED, EI, EE, EF
FC, FI, FE, EK
5.0 V ± 5%
FT29F040B-70
FT29F040B-90
FT29F040B-120
FT29F040B-150
PC, PI, PE, PD, PF, PK,
JC, JI, JE, JD, JF, JK
EC, EI, EE, ED, EF, EK
FC, FI, FE
5.0 V ± 10%
Rev 2
Page 6 of 36
FT29F040B
mation needed to execute the command. The contents
of the register serve as inputs to the internal state ma-
chine. The state machine outputs dictate the function of
the device. The appropriate device bus operations
table lists the inputs and control levels required, and the
resulting output. The following subsections describe
each of these operations in further detail.
DEVICE BUS OPERATIONS
This section describes the requirements and use of the
device bus operations, which are initiated through the
internal command register. The command register it-
self does not occupy any addressable memory
location. The register is composed of latches that store
the commands, along with the address and data infor-
Table 1. FT29F040B Device Bus Operations
CE# OE# WE#
Operation
A0–A20
DQ0–DQ7
Read
L
L
H
A
A
D
OUT
IN
IN
Write
L
H
X
X
H
L
X
X
H
D
IN
CMOS Standby
TTL Standby
Output Disable
V
± 0.5 V
X
High-Z
High-Z
High-Z
CC
H
L
X
X
Legend:
L = Logic Low = V , H = Logic High = V , V = 12.0 ± 0.5 V, X = Don’t Care, D = Data In, D
= Data Out, A = Address In
IL
IH
ID
IN
OUT
IN
Note: See the “Sector Protection/Unprotection” section. for more information.
indicate the address space that each sector occupies.
A “sector address” consists of the address bits required
to uniquely select a sector. See the “Command Defini-
tions” section for details on erasing a sector or the
entire chip, or suspending/resuming the erase
operation.
Requirements for Reading Array Data
To read array data from the outputs, the system must
drive the CE# and OE# pins to V . CE# is the power
IL
control and selects the device. OE# is the output con-
trol and gates array data to the output pins. WE# should
remain at V .
IH
After the system writes the autoselect command se-
quence, the device enters the autoselect mode. The
system can then read autoselect codes from the inter-
nal register (which is separate from the memory array)
on DQ7–DQ0. Standard read cycle timings apply in this
mode. Refer to the “Autoselect Mode” and “Autoselect
Command Sequence” sections for more information.
The internal state machine is set for reading array data
upon device power-up, or after a hardware reset. This
ensures that no spurious alteration of the memory con-
tent occurs during the power transition. No command is
necessary in this mode to obtain array data. Standard
microprocessor read cycles that assert valid addresses
on the device address inputs produce valid data on the
device data outputs. The device remains enabled for
read access until the command register contents are
altered.
I
in the DC Characteristics table represents the ac-
CC2
tive current specification for the write mode. The “AC
Characteristics” section contains timing specification
tables and timing diagrams for write operations.
See “Reading Array Data” for more information. Refer
to the AC Read Operations table for timing specifica-
tions and to the Read Operations Timings diagram for
Program and Erase Operation Status
During an erase or program operation, the system may
check the status of the operation by reading the status
the timing waveforms. I
table represents the active current specification for
reading array data.
in the DC Characteristics
CC1
bits on DQ7–DQ0. Standard read cycle timings and I
CC
read specifications apply. Refer to “Write Operation
Status” for more information, and to each AC Charac-
teristics section for timing diagrams.
Writing Commands/Command Sequences
To write a command or command sequence (which in-
cludes programming data to the device and erasing
sectors of memory), the system must drive WE# and
Standby Mode
When the system is not reading or writing to the device,
it can place the device in the standby mode. In this
mode, current consumption is greatly reduced, and the
CE# to V , and OE# to V .
IL
IH
An erase operation can erase one sector, multiple sec-
tors, or the entire device. The Sector Address Tables
Rev 2
Page 7 of 36
FT29F040B
outputs are placed in the high impedance state, inde-
pendent of the OE# input.
If the device is deselected during erasure or program-
ming, the device draws active current until the
operation is completed.
The device enters the CMOS standby mode when the
CE# pin is held at V ± 0.5 V. (Note that this is a more
I
in the DC Characteristics tables represents the
CC3
CC
restricted voltage range than V .) The device enters
standby current specification.
IH
the TTL standby mode when CE# is held at V . The
IH
Output Disable Mode
device requires the standard access time (t ) before it
CE
is ready to read data.
When the OE# input is at V , output from the device is
IH
disabled. The output pins are placed in the high imped-
ance state.
Table 2. Sector Addresses Table
A17 A16
Sector
SA0
SA1
SA2
SA3
SA4
SA5
SA6
SA7
A18
0
Address Range
00000h–0FFFFh
10000h–1FFFFh
20000h–2FFFFh
30000h–3FFFFh
40000h–4FFFFh
50000h–5FFFFh
60000h–6FFFFh
70000h–7FFFFh
0
0
0
0
1
1
0
0
1
1
1
0
1
0
1
0
1
0
0
1
1
1
1
Note: All sectors are 64 Kbytes in size.
Rev 2
Page 8 of 36
FT29F040B
Autoselect Mode
The autoselect mode provides manufacturer and de-
vice identification, and sector protection verification,
through identifier codes output on DQ7–DQ0. This
mode is primarily intended for programming equipment
to automatically match a device to be programmed with
its corresponding programming algorithm. However,
the autoselect codes can also be accessed in-system
through the command register.
address must appear on the appropriate highest order
address bits. Refer to the corresponding Sector Ad-
dress Tables. The Command Definitions table shows
the remaining address bits that are don’t care. When all
necessary bits have been set as required, the program-
ming equipment may then read the corresponding
identifier code on DQ7–DQ0.
To access the autoselect codes in-system, the host
system can issue the autoselect command via the
command register, as shown in the Command Defini-
When using programming equipment, the autoselect
mode requires V (11.5 V to 12.5 V) on address pin
ID
A9. Address pins A6, A1, and A0 must be as shown in
Autoselect Codes (High Voltage Method) table. In addi-
tion, when verifying sector protection, the sector
tions table. This method does not require V . See
“Command Definitions” for details on using the autose-
lect mode.
ID
Table 3. FT29F040B Autoselect Codes (High Voltage Method)
Identifier Code on
DQ7-DQ0
Description
A18–A16 A15–A10 A9 A8–A7 A6 A5–A2 A1
A0
Manufacturer ID: AMD
Device ID: Am29F040B
X
X
X
X
V
V
X
X
V
V
X
X
V
V
V
01h
ID
ID
IL
IL
IL
IL
IL
V
A4h
IH
01h (protected)
00h (unprotected)
Sector Protection
Verification
Sector
Address
X
V
X
V
X
V
V
IL
ID
IL
IH
gramming, which might otherwise be caused by
Sector Protection/Unprotection
spurious system level signals during V power-up and
CC
The hardware sector protection feature disables both
program and erase operations in any sector. The hard-
ware sector unprotection feature re-enables both
program and erase operations in previously protected
sectors.
power-down transitions, or from system noise.
Low V
Write Inhibit
CC
When V
is less than V
, the device does not ac-
LKO
CC
cept any write cycles. This protects data during V
CC
power-up and power-down. The command register and
all internal program/erase circuits are disabled, and the
Sector protection/unprotection must be implemented
using programming equipment. The procedure re-
device resets. Subsequent writes are ignored until V
quires a high voltage (V ) on address pin A9 and the
CC
ID
is greater than V
. The system must provide the
control pins. Details on this method are provided in a
supplement, publication number 19957. Contact an
representative to obtain a copy of the appropriate
document.
LKO
proper signals to the control pins to prevent uninten-
tional writes when V is greater than V
.
CC
LKO
Write Pulse “Glitch” Protection
The device is shipped with all sectors unprotected.
Force offer the option of programming and protecting
sectors at its factory prior to shipping the device
Contact a Force representative for details.
Noise pulses of less than 5 ns (typical) on OE#, CE# or
WE# do not initiate a write cycle.
Logical Inhibit
Write cycles are inhibited by holding any one of OE# =
It is possible to determine whether a sector is protected
or unprotected. See “Autoselect Mode” for details.
V , CE# = V or WE# = V . To initiate a write cycle,
IL
IH
IH
CE# and WE# must be a logical zero while OE# is a
logical one.
Hardware Data Protection
Power-Up Write Inhibit
The command sequence requirement of unlock cycles
for programming or erasing provides data protection
against inadvertent writes (refer to the Command Defi-
nitions table). In addition, the following hardware data
protection measures prevent accidental erasure or pro-
If WE# = CE# = V and OE# = V during power up, the
IL IH
device does not accept commands on the rising edge
of WE#. The internal state machine is automatically
reset to reading array data on power-up.
Rev 2
Page 9 of 36
FT29F040B
COMMAND DEFINITIONS
Writing specific address and data commands or se-
quences into the command register initiates device
operations. The Command Definitions table defines the
valid register command sequences. Writing incorrect
address and data values or writing them in the im-
proper sequence resets the device to reading array
data.
however, the device ignores reset commands until the
operation is complete.
The reset command may be written between the se-
quence cycles in an autoselect command sequence.
Once in the autoselect mode, the reset command must
be written to return to reading array data (also applies
to autoselect during Erase Suspend).
All addresses are latched on the falling edge of WE# or
CE#, whichever happens later. All data is latched on
the rising edge of WE# or CE#, whichever happens
first. Refer to the appropriate timing diagrams in the
“AC Characteristics” section.
If DQ5 goes high during a program or erase operation,
writing the reset command returns the device to read-
ing array data (also applies during Erase Suspend).
Autoselect Command Sequence
The autoselect command sequence allows the host
system to access the manufacturer and devices codes,
and determine whether or not a sector is protected.
The Command Definitions table shows the address
and data requirements. This method is an alternative to
that shown in the Autoselect Codes (High Voltage
Method) table, which is intended for PROM program-
Reading Array Data
The device is automatically set to reading array data
after device power-up. No commands are required to
retrieve data. The device is also ready to read array
data after completing an Embedded Program or Em-
bedded Erase algorithm.
After the device accepts an Erase Suspend command,
the device enters the Erase Suspend mode. The sys-
tem can read array data using the standard read
timings, except that if it reads at an address within
erase-suspended sectors, the device outputs status
data. After completing a programming operation in the
Erase Suspend mode, the system may once again
read array data with the same exception. See “Erase
Suspend/Erase Resume Commands” for more infor-
mation on this mode.
mers and requires V on address bit A9.
ID
The autoselect command sequence is initiated by writ-
ing two unlock cycles, followed by the autoselect
command. The device then enters the autoselect
mode, and the system may read at any address any
number of times, without initiating another command
sequence.
A read cycle at address XX00h or retrieves the manu-
facturer code. A read cycle at address XX01h returns
the device code. A read cycle containing a sector ad-
dress (SA) and the address 02h in returns 01h if that
sector is protected, or 00h if it is unprotected. Refer to
the Sector Address tables for valid sector addresses.
The system must issue the reset command to re-en-
able the device for reading array data if DQ5 goes high,
or while in the autoselect mode. See the “Reset Com-
mand” section, next.
The system must write the reset command to exit the
autoselect mode and return to reading array data.
See also “Requirements for Reading Array Data” in the
“Device Bus Operations” section for more information.
The Read Operations table provides the read parame-
ters, and Read Operation Timings diagram shows the
timing diagram.
Byte Program Command Sequence
Programming is a four-bus-cycle operation. The pro-
gram command sequence is initiated by writing two
unlock write cycles, followed by the program set-up
command. The program address and data are written
next, which in turn initiate the Embedded Program al-
gorithm. The system is not required to provide further
controls or timings. The device automatically provides
internally generated program pulses and verify the pro-
grammed cell margin. The Command Definitions take
shows the address and data requirements for the byte
program command sequence.
Reset Command
Writing the reset command to the device resets the de-
vice to reading array data. Address bits are don’t care
for this command.
The reset command may be written between the se-
quence cycles in an erase command sequence before
erasing begins. This resets the device to reading array
data. Once erasure begins, however, the device ig-
nores reset commands until the operation is complete.
When the Embedded Program algorithm is complete,
the device then returns to reading array data and ad-
dresses are no longer latched. The system can
determine the status of the program operation by using
DQ7 or DQ6. See “Write Operation Status” for informa-
tion on these status bits.
The reset command may be written between the se-
quence cycles in a program command sequence
before programming begins. This resets the device to
reading array data (also applies to programming in
Erase Suspend mode). Once programming begins,
Rev 2
Page 10 of 36
FT29F040B
Table 4.
Command Definitions
Bus Cycles (Notes 2– 4)
Third Fourth
Addr Data Addr Data Addr Data Addr Data
Command
Sequence
(Note 1)
First
Second
Fifth
Sixth
Addr Data Addr Data
Read (Note 5)
1
1
4
4
RA
XXX
555
555
RD
F0
Reset (Note 6)
Manufacturer ID
Device ID
AA
AA
2AA
2AA
55
55
555
555
90
90
X00
X01
01
A4
00
Autoselect
(Note 7)
Sector Protect Verify
(Note 8)
SA
X02
4
555
AA
2AA
55
555
90
01
Program
4
6
6
1
1
555
555
AA
AA
AA
B0
30
2AA
2AA
2AA
55
55
55
555
555
555
A0
80
80
PA
555
555
PD
AA
AA
Chip Erase
Sector Erase
2AA
2AA
55
55
555
SA
10
30
555
Erase Suspend (Note 9)
Erase Resume (Note 10)
XXX
XXX
Legend:
X = Don’t care
PD = Data to be programmed at location PA. Data latches on the
rising edge of WE# or CE# pulse, whichever happens first.
RA = Address of the memory location to be read.
SA = Address of the sector to be verified (in autoselect mode) or
erased. Address bits A18–A16 select a unique sector.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed.
Addresses latch on the falling edge of the WE# or CE# pulse,
whichever happens later.
Notes:
1. See Table 1 for description of bus operations.
7. The fourth cycle of the autoselect command sequence is a
read cycle.
2. All values are in hexadecimal.
8. The data is 00h for an unprotected sector and 01h for a
protected sector.See “Autoselect Command Sequence” for
more information.
3. Except when reading array or autoselect data, all bus cycles
are write operations.
4. Address bits A18–A11 are don’t cares for unlock and
command cycles, unless SA or PA required.
9. The system may read and program in non-erasing sectors, or
enter the autoselect mode, when in the Erase Suspend
mode. The Erase Suspend command is valid only during a
sector erase operation.
5. No unlock or command cycles required when reading array data.
6. The Reset command is required to return to reading array
data when device is in the autoselect mode, or if DQ5 goes
high (while the device is providing status data).
10. The Erase Resume command is valid only during the Erase
Suspend mode.
Rev 2
Page 11 of 36
FT29F040B
Any commands written to the device during the Em-
bedded Program Algorithm are ignored.
rithm automatically preprograms and verifies the entire
memory for an all zero data pattern prior to electrical
erase. The system is not required to provide any con-
trols or timings during these operations. The Command
Definitions table shows the address and data require-
ments for the chip erase command sequence.
Programming is allowed in any sequence and across
sector boundaries. A bit cannot be programmed
from a “0” back to a “1”. Attempting to do so may halt
the operation and set DQ5 to “1”, or cause the Data#
Polling algorithm to indicate the operation was suc-
cessful. However, a succeeding read shows that the
data is still “0”. Only erase operations can convert a “0”
to a “1”.
Any commands written to the chip during the Embed-
ded Erase algorithm are ignored.
The system can determine the status of the erase op-
eration by using DQ7, DQ6, or DQ2. See “Write
Operation Status” for information on these status bits.
When the Embedded Erase algorithm is complete, the
device returns to reading array data and addresses are
no longer latched.
START
Figure 2 illustrates the algorithm for the erase opera-
tion. See the Erase and Program Operations tables in
“AC Characteristics” for parameters, and to the Chip/
Sector Erase Operation Timings for timing waveforms.
Write Program
Command Sequence
Sector Erase Command Sequence
Sector erase is a six bus cycle operation. The sector
erase command sequence is initiated by writing two un-
lock cycles, followed by a set-up command. Two
additional unlock write cycles are then followed by the
address of the sector to be erased, and the sector
erase command. The Command Definitions table
shows the address and data requirements for the sec-
tor erase command sequence.
Data Poll
from System
Embedded
Program
algorithm
in progress
Verify Data?
No
The device does not require the system to preprogram
the memory prior to erase. The Embedded Erase algo-
rithm automatically programs and verifies the sector for
an all zero data pattern prior to electrical erase. The
system is not required to provide any controls or tim-
ings during these operations.
Yes
No
Increment Address
Last Address?
Yes
After the command sequence is written, a sector erase
time-out of 50 µs begins. During the time-out period,
additional sector addresses and sector erase com-
mands may be written. Loading the sector erase buffer
may be done in any sequence, and the number of sec-
tors may be from one sector to all sectors. The time
between these additional cycles must be less than 50
µs, otherwise the last address and command might not
be accepted, and erasure may begin. It is recom-
mended that processor interrupts be disabled during
this time to ensure all commands are accepted. The in-
terrupts can be re-enabled after the last Sector Erase
command is written. If the time between additional sec-
tor erase commands can be assumed to be less than
50 µs, the system need not monitor DQ3. Any com-
mand other than Sector Erase or Erase Suspend
during the time-out period resets the device to
reading array data. The system must rewrite the com-
mand sequence and any additional sector addresses
and commands.
Programming
Completed
Note: See the appropriate Command Definitions table for
program command sequence.
Figure 1. Program Operation
Chip Erase Command Sequence
Chip erase is a six-bus-cycle operation. The chip erase
command sequence is initiated by writing two unlock
cycles, followed by a set-up command. Two additional
unlock write cycles are then followed by the chip erase
command, which in turn invokes the Embedded Erase
algorithm. The device does not require the system to
preprogram prior to erase. The Embedded Erase algo-
Rev 2
Page 12 of 36
FT29F040B
The system can monitor DQ3 to determine if the sector
erase timer has timed out. (See the “DQ3: Sector Erase
Timer” section.) The time-out begins from the rising
edge of the final WE# pulse in the command sequence.
non-suspended sectors. The system can determine
the status of the program operation using the DQ7 or
DQ6 status bits, just as in the standard program oper-
ation. See “Write Operation Status” for more
information.
Once the sector erase operation has begun, only the
Erase Suspend command is valid. All other commands
are ignored.
The system may also write the autoselect command
sequence when the device is in the Erase Suspend
mode. The device allows reading autoselect codes
even at addresses within erasing sectors, since the
codes are not stored in the memory array. When the
device exits the autoselect mode, the device reverts to
the Erase Suspend mode, and is ready for another
valid operation. See “Autoselect Command Sequence”
for more information.
When the Embedded Erase algorithm is complete, the
device returns to reading array data and addresses are
no longer latched. The system can determine the sta-
tus of the erase operation by using DQ7, DQ6, or DQ2.
Refer to “Write Operation Status” for information on
these status bits.
Figure 2 illustrates the algorithm for the erase opera-
tion. Refer to the Erase/Program Operations tables in
the “AC Characteristics” section for parameters, and to
the Sector Erase Operations Timing diagram for timing
waveforms.
The system must write the Erase Resume command
(address bits are “don’t care”) to exit the erase suspend
mode and continue the sector erase operation. Further
writes of the Resume command are ignored. Another
Erase Suspend command can be written after the de-
vice has resumed erasing.
Erase Suspend/Erase Resume Commands
The Erase Suspend command allows the system to in-
terrupt a sector erase operation and then read data
from, or program data to, any sector not selected for
erasure. This command is valid only during the sector
erase operation, including the 50 µs time-out period
during the sector erase command sequence. The
Erase Suspend command is ignored if written during
the chip erase operation or Embedded Program algo-
rithm. Writing the Erase Suspend command during the
Sector Erase time-out immediately terminates the
time-out period and suspends the erase operation. Ad-
dresses are “don’t-cares” when writing the Erase
Suspend command.
START
Write Erase
Command Sequence
Data Poll
from System
Embedded
When the Erase Suspend command is written during a
sector erase operation, the device requires a maximum
of 20 µs to suspend the erase operation. However,
when the Erase Suspend command is written during
the sector erase time-out, the device immediately ter-
minates the time-out period and suspends the erase
operation.
Erase
algorithm
in progress
No
Data = FFh?
Yes
After the erase operation has been suspended, the
system can read array data from or program data to
any sector not selected for erasure. (The device “erase
suspends” all sectors selected for erasure.) Normal
read and write timings and command definitions apply.
Reading at any address within erase-suspended sec-
tors produces status data on DQ7–DQ0. The system
can use DQ7, or DQ6 and DQ2 together, to determine
if a sector is actively erasing or is erase-suspended.
See “Write Operation Status” for information on these
status bits.
Erasure Completed
Notes:
1. See the appropriate Command Definitions table for erase
command sequence.
2. See “DQ3: Sector Erase Timer” for more information.
After an erase-suspended program operation is com-
plete, the system can once again read array data within
Figure 2. Erase Operation
Rev 2
Page 13 of 36
FT29F040B
COMMAND DEFINITIONS
Writing specific address and data commands or se-
quences into the command register initiates device
operations. The Command Definitions table defines the
valid register command sequences. Writing incorrect
address and data values or writing them in the im-
proper sequence resets the device to reading array
data.
however, the device ignores reset commands until the
operation is complete.
The reset command may be written between the se-
quence cycles in an autoselect command sequence.
Once in the autoselect mode, the reset command must
be written to return to reading array data (also applies
to autoselect during Erase Suspend).
All addresses are latched on the falling edge of WE# or
CE#, whichever happens later. All data is latched on
the rising edge of WE# or CE#, whichever happens
first. Refer to the appropriate timing diagrams in the
“AC Characteristics” section.
If DQ5 goes high during a program or erase operation,
writing the reset command returns the device to read-
ing array data (also applies during Erase Suspend).
Autoselect Command Sequence
The autoselect command sequence allows the host
system to access the manufacturer and devices codes,
and determine whether or not a sector is protected.
The Command Definitions table shows the address
and data requirements. This method is an alternative to
that shown in the Autoselect Codes (High Voltage
Method) table, which is intended for PROM program-
mers and requires VID on address bit A9.
Reading Array Data
The device is automatically set to reading array data
after device power-up. No commands are required to
retrieve data. The device is also ready to read array
data after completing an Embedded Program or Em-
bedded Erase algorithm.
After the device accepts an Erase Suspend command,
the device enters the Erase Suspend mode. The sys-
tem can read array data using the standard read
timings, except that if it reads at an address within
erase-suspended sectors, the device outputs status
data. After completing a programming operation in the
Erase Suspend mode, the system may once again
read array data with the same exception. See “Erase
Suspend/Erase Resume Commands” for more infor-
mation on this mode.
The autoselect command sequence is initiated by writ-
ing two unlock cycles, followed by the autoselect
command. The device then enters the autoselect
mode, and the system may read at any address any
number of times, without initiating another command
sequence.
A read cycle at address XX00h or retrieves the manu-
facturer code. A read cycle at address XX01h returns
the device code. A read cycle containing a sector ad-
dress (SA) and the address 02h in returns 01h if that
sector is protected, or 00h if it is unprotected. Refer to
the Sector Address tables for valid sector addresses.
The system must issue the reset command to re-en-
able the device for reading array data if DQ5 goes high,
or while in the autoselect mode. See the “Reset Com-
mand” section, next.
The system must write the reset command to exit the
autoselect mode and return to reading array data.
See also “Requirements for Reading Array Data” in the
“Device Bus Operations” section for more information.
The Read Operations table provides the read parame-
ters, and Read Operation Timings diagram shows the
timing diagram.
Byte Program Command Sequence
Programming is a four-bus-cycle operation. The pro-
gram command sequence is initiated by writing two
unlock write cycles, followed by the program set-up
command. The program address and data are written
next, which in turn initiate the Embedded Program al-
gorithm. The system is not required to provide further
controls or timings. The device automatically provides
internally generated program pulses and verify the pro-
grammed cell margin. The Command Definitions take
shows the address and data requirements for the byte
program command sequence.
Reset Command
Writing the reset command to the device resets the de-
vice to reading array data. Address bits are don’t care
for this command.
The reset command may be written between the se-
quence cycles in an erase command sequence before
erasing begins. This resets the device to reading array
data. Once erasure begins, however, the device ig-
nores reset commands until the operation is complete.
When the Embedded Program algorithm is complete,
the device then returns to reading array data and ad-
dresses are no longer latched. The system can
determine the status of the program operation by using
DQ7 or DQ6. See “Write Operation Status” for informa-
tion on these status bits.
The reset command may be written between the se-
quence cycles in a program command sequence
before programming begins. This resets the device to
reading array data (also applies to programming in
Erase Suspend mode). Once programming begins,
Rev 2
Page 14 of 36
FT29F040B
WRITE OPERATION STATUS
The device provides several bits to determine the sta-
tus of a write operation: DQ2, DQ3, DQ5, DQ6, and
DQ7. Table 5 and the following subsections describe
the functions of these bits. DQ7 and DQ6 each offer a
method for determining whether a program or erase
operation is complete or in progress. These three bits
are discussed first.
rithms) figure in the “AC Characteristics” section
illustrates this.
Table 5 shows the outputs for Data# Polling on DQ7.
Figure 3 shows the Data# Polling algorithm.
START
DQ7: Data# Polling
The Data# Polling bit, DQ7, indicates to the host sys-
tem whether an Embedded Algorithm is in progress or
completed, or whether the device is in Erase Suspend.
Data# Polling is valid after the rising edge of the final
WE# pulse in the program or erase command
sequence.
Read DQ7–DQ0
Addr = VA
During the Embedded Program algorithm, the device
outputs on DQ7 the complement of the datum pro-
grammed to DQ7. This DQ7 status also applies to
programming during Erase Suspend. When the Em-
bedded Program algorithm is complete, the device
outputs the datum programmed to DQ7. The system
must provide the program address to read valid status
information on DQ7. If a program address falls within a
protected sector, Data# Polling on DQ7 is active for ap-
proximately 2 µs, then the device returns to reading
array data.
Yes
DQ7 = Data?
No
No
DQ5 = 1?
Yes
During the Embedded Erase algorithm, Data# Polling
produces a “0” on DQ7. When the Embedded Erase al-
gorithm is complete, or if the device enters the Erase
Suspend mode, Data# Polling produces a “1” on DQ7.
This is analogous to the complement/true datum output
described for the Embedded Program algorithm: the
erase function changes all the bits in a sector to “1”;
prior to this, the device outputs the “complement,” or
“0.” The system must provide an address within any of
the sectors selected for erasure to read valid status in-
formation on DQ7.
Read DQ7–DQ0
Addr = VA
Yes
DQ7 = Data?
No
After an erase command sequence is written, if all sec-
tors selected for erasing are protected, Data# Polling
on DQ7 is active for approximately 100 µs, then the de-
vice returns to reading array data. If not all selected
sectors are protected, the Embedded Erase algorithm
erases the unprotected sectors, and ignores the se-
lected sectors that are protected.
PASS
FAIL
Notes:
1. VA = Valid address for programming. During a sector
erase operation, a valid address is an address within any
sector selected for erasure. During chip erase, a valid
address is any non-protected sector address.
When the system detects DQ7 has changed from the
complement to true data, it can read valid data at
DQ7–DQ0 on the following read cycles. This is be-
cause DQ7 may change asynchronously with
DQ0–DQ6 while Output Enable (OE#) is asserted low.
The Data# Polling Timings (During Embedded Algo-
2. DQ7 should be rechecked even if DQ5 = “1” because
DQ7 may change simultaneously with DQ5.
Figure 3. Data# Polling Algorithm
Rev 2
Page 15 of 36
FT29F040B
sure. (The system may use either OE# or CE# to
control the read cycles.) But DQ2 cannot distinguish
whether the sector is actively erasing or is erase-sus-
pended. DQ6, by comparison, indicates whether the
device is actively erasing, or is in Erase Suspend, but
cannot distinguish which sectors are selected for era-
sure. Thus, both status bits are required for sector and
mode information. Refer to Table 5 to compare outputs
for DQ2 and DQ6.
DQ6: Toggle Bit I
Toggle Bit I on DQ6 indicates whether an Embedded
Program or Erase algorithm is in progress or complete,
or whether the device has entered the Erase Suspend
mode. Toggle Bit I may be read at any address, and is
valid after the rising edge of the final WE# pulse in the
command sequence (prior to the program or erase op-
eration), and during the sector erase time-out.
During an Embedded Program or Erase algorithm op-
eration, successive read cycles to any address cause
DQ6 to toggle. (The system may use either OE# or
CE# to control the read cycles.) When the operation is
complete, DQ6 stops toggling.
Figure 4 shows the toggle bit algorithm in flowchart
form, and the section “DQ2: Toggle Bit II” explains the
algorithm. See also the “DQ6: Toggle Bit I” subsection.
Refer to the Toggle Bit Timings figure for the toggle bit
timing diagram. The DQ2 vs. DQ6 figure shows the dif-
ferences between DQ2 and DQ6 in graphical form.
After an erase command sequence is written, if all sec-
tors selected for erasing are protected, DQ6 toggles for
approximately 100 µs, then returns to reading array
data. If not all selected sectors are protected, the Em-
bedded Erase algorithm erases the unprotected
sectors, and ignores the selected sectors that are
protected.
Reading Toggle Bits DQ6/DQ2
Refer to Figure 4 for the following discussion. When-
ever the system initially begins reading toggle bit
status, it must read DQ7–DQ0 at least twice in a row to
determine whether a toggle bit is toggling. Typically, a
system would note and store the value of the toggle bit
after the first read. After the second read, the system
would compare the new value of the toggle bit with the
first. If the toggle bit is not toggling, the device has com-
pleted the program or erase operation. The system can
read array data on DQ7–DQ0 on the following read
cycle.
The system can use DQ6 and DQ2 together to deter-
mine whether a sector is actively erasing or is erase-
suspended. When the device is actively erasing (that is,
the Embedded Erase algorithm is in progress), DQ6
toggles. When the device enters the Erase Suspend
mode, DQ6 stops toggling. However, the system must
also use DQ2 to determine which sectors are erasing
or erase-suspended. Alternatively, the system can use
DQ7 (see the subsection on “DQ7: Data# Polling”).
However, if after the initial two read cycles, the system
determines that the toggle bit is still toggling, the sys-
tem also should note whether the value of DQ5 is high
(see the section on DQ5). If it is, the system should
then determine again whether the toggle bit is toggling,
since the toggle bit may have stopped toggling just as
DQ5 went high. If the toggle bit is no longer toggling,
the device has successfully completed the program or
erase operation. If it is still toggling, the device did not
complete the operation successfully, and the system
must write the reset command to return to reading
array data.
If a program address falls within a protected sector,
DQ6 toggles for approximately 2 µs after the program
command sequence is written, then returns to reading
array data.
DQ6 also toggles during the erase-suspend-program
mode, and stops toggling once the Embedded Pro-
gram algorithm is complete.
The Write Operation Status table shows the outputs for
Toggle Bit I on DQ6. Refer to Figure 4 for the toggle bit
algorithm, and to the Toggle Bit Timings figure in the
“AC Characteristics” section for the timing diagram.
The DQ2 vs. DQ6 figure shows the differences be-
tween DQ2 and DQ6 in graphical form. See also the
subsection on “DQ2: Toggle Bit II”.
The remaining scenario is that the system initially de-
termines that the toggle bit is toggling and DQ5 has not
gone high. The system may continue to monitor the
toggle bit and DQ5 through successive read cycles, de-
termining the status as described in the previous
paragraph. Alternatively, it may choose to perform
other system tasks. In this case, the system must start
at the beginning of the algorithm when it returns to de-
termine the status of the operation (top of Figure 4).
DQ2: Toggle Bit II
The “Toggle Bit II” on DQ2, when used with DQ6, indi-
cates whether a particular sector is actively erasing
(that is, the Embedded Erase algorithm is in progress),
or whether that sector is erase-suspended. Toggle Bit
II is valid after the rising edge of the final WE# pulse in
the command sequence.
DQ5: Exceeded Timing Limits
DQ5 indicates whether the program or erase time has
exceeded a specified internal pulse count limit. Under
these conditions DQ5 produces a “1.” This is a failure
condition that indicates the program or erase cycle was
DQ2 toggles when the system reads at addresses
within those sectors that have been selected for era-
not successfully completed.
Rev 2
Page 16 of 36
FT29F040B
The DQ5 failure condition may appear if the system
tries to program a “1” to a location that is previously pro-
grammed to “0.” Only an erase operation can change
a “0” back to a “1.” Under this condition, the device
halts the operation, and when the operation has ex-
ceeded the timing limits, DQ5 produces a “1.”
START
Under both these conditions, the system must issue the
reset command to return the device to reading array
data.
Read DQ7–DQ0
Read DQ7–DQ0
(Note 1)
No
DQ3: Sector Erase Timer
After writing a sector erase command sequence, the
system may read DQ3 to determine whether or not an
erase operation has begun. (The sector erase timer
does not apply to the chip erase command.) If addi-
tional sectors are selected for erasure, the entire time-
out also applies after each additional sector erase com-
mand. When the time-out is complete, DQ3 switches
from “0” to “1.” The system may ignore DQ3 if the sys-
tem can guarantee that the time between additional
sector erase commands is always less than 50 µs. See
also the “Sector Erase Command Sequence” section.
Toggle Bit
= Toggle?
Yes
No
DQ5 = 1?
Yes
After the sector erase command sequence is written,
the system should read the status on DQ7 (Data# Poll-
ing) or DQ6 (Toggle Bit I) to ensure the device has
accepted the command sequence, and then read DQ3.
If DQ3 is “1”, the internally controlled erase cycle has
begun; all further commands (other than Erase Sus-
pend) are ignored until the erase operation is complete.
If DQ3 is “0”, the device accepts additional sector erase
commands. To ensure the command has been ac-
cepted, the system software should check the status of
DQ3 prior to and following each subsequent sector
erase command. If DQ3 is high on the second status
check, the last command might not have been ac-
cepted. Table 5 shows the outputs for DQ3.
Read DQ7–DQ0
Twice
(Notes 1,
2)
Toggle Bit
= Toggle?
No
Yes
Program/Erase
Operation Not
Complete, Write
Reset Command
Program/Erase
Operation Complete
Notes:
1. Read toggle bit twice to determine whether or not it is
toggling. See text.
2. Recheck toggle bit because it may stop toggling as DQ5
changes to “1”. See text.
Figure 4. Toggle Bit Algorithm
Rev 2
Page 17 of 36
FT29F040B
Table 5. Write Operation Status
DQ7
DQ5
DQ2
Operation
(Note 1)
DQ7#
0
DQ6
(Note 2)
DQ3
N/A
1
(Note 1)
No toggle
Toggle
Embedded Program Algorithm
Embedded Erase Algorithm
Toggle
Toggle
0
0
Standard
Mode
Reading within Erase
Suspended Sector
1
No toggle
0
N/A
Toggle
Erase
Suspend Reading within Non-Erase
Data
Data
Data
0
Data
N/A
Data
N/A
Mode
Suspended Sector
Erase-Suspend-Program
DQ7#
Toggle
Notes:
1. DQ7 and DQ2 require a valid address when reading status information. Refer to the appropriate subsection for further details.
2. DQ5 switches to ‘1’ when an Embedded Program or Embedded Erase operation has exceeded the maximum timing limits.
See “DQ5: Exceeded Timing Limits” for more information.
Rev 2
Page 18 of 36
FT29F040B
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . . –65°C to +125°C
20 ns
20 ns
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . –55°C to +125°C
+0.8 V
Voltage with Respect to Ground
–0.5 V
–2.0 V
V
(Note 1) . . . . . . . . . . . . . . . . .–2.0 V to 7.0 V
CC
A9, OE# (Note 2). . . . . . . . . . . . .–2.0 V to 12.5 V
All other pins (Note 1) . . . . . . . . . .–2.0 V to 7.0 V
Output Short Circuit Current (Note 3) . . . . . . 200 mA
20 ns
Figure 5. Maximum Negative
Overshoot Waveform
Notes:
1. Minimum DC voltage on input or I/O pins is –0.5 V. During
voltage transitions, inputs may undershoot V to –2.0 V
SS
for periods of up to 20 ns. See Figure 5. Maximum DC
voltage on input and I/O pins is V
+ 0.5 V. During
CC
voltage transitions, input and I/O pins may overshoot to
+ 2.0 V for periods up to 20 ns. See Figure 6.
20 ns
V
CC
2. Minimum DC input voltage on A9 pin is –0.5 V. During
V
CC
voltage transitions, A9 and OE# may undershoot V to
+2.0 V
SS
–2.0 V for periods of up to 20 ns. See Figure 5. Maximum
DC input voltage on A9 and OE# is 12.5 V which may
overshoot to 13.5 V for periods up to 20 ns.
V
CC
+0.5 V
2.0 V
3. No more than one output shorted to ground at a time.
Duration of the short circuit should not be greater than
one second.
20 ns
20 ns
Figure 6. Maximum Positive
Overshoot Waveform
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device. This is
a stress rating only; functional operation of the device at
these or any other conditions above those indicated in the op-
erational sections of this specification is not implied. Expo-
sure of the device to absolute maximum rating conditions for
extended periods may affect device reliability.
V
for ± 10% devices . . . . . . . . . . . +4.5 V to +5.5 V
OPERATING RANGES
CC
Operating ranges define those limits between which the
functionality of the device is guaranteed.
Commercial (C) Devices
Ambient Temperature (T ) . . . . . . . . . . . 0°C to +70°C
A
Industrial (I) Devices
Ambient Temperature (T ) . . . . . . . . . –40°C to +85°C
A
Extended (E) Devices
Ambient Temperature (T ) . . . . . . . . –55°C to +125°C
A
V
Supply Voltages
CC
V
for ± 5% devices. . . . . . . . . . .+4.75 V to +5.25 V
CC
Rev 2
Page 19 of 36
FT29F040B
DC CHARACTERISTICS
TTL/NMOS Compatible
Parameter
Symbol
Parameter Description
Test Description
= V to V , V = V Max
Min
Typ
Max
±1.0
50
Unit
µA
I
Input Load Current
V
V
V
LI
IN
SS
CC
CC
CC
I
A9 Input Load Current
Output Leakage Current
= V Max, A9 = 12.5 V
µA
LIT
CC
OUT
CC
I
= V to V , V = V Max
±1.0
30
µA
LO
SS
CC CC
CC
I
I
I
V
V
Active Read Current (Notes 1, 2) CE# = V , OE# = V
20
30
mA
CC1
CC
IL
IH
Active Write (Program/Erase)
Current (Notes 2, 3, 4)
CC
CE# = V , OE# = V
40
mA
CC2
IL
IH
V
Standby Current (Note 2)
CE# = V
0.4
1.0
0.8
mA
V
CC3
CC
IH
V
Input Low Level
Input High Level
–0.5
2.0
IL
V
V
V
+ 0.5
CC
V
IH
Voltage for Autoselect
and Sector Protect
V
= 5.25 V
CC
10.5
12.5
0.45
V
ID
V
Output Low Voltage
Output High Voltage
I
I
= 12 mA, V = V Min
V
V
V
OL
OL
CC
CC
V
= –2.5 mA, V = V Min
2.4
3.2
OH
OH
CC
CC
V
Low V Lock-Out Voltage
4.2
LKO
CC
CMOS Compatible
Parameter
Symbol
Parameter Description
Test Description
Min
Typ
Max
±1.0
50
Unit
µA
I
Input Load Current
V
V
V
= V to V , V = V Max
LI
IN
SS
CC
CC
CC
I
A9 Input Load Current
Output Leakage Current
= V Max, A9 = 12.5 V
µA
LIT
CC
CC
I
= V to V , V = V Max
±1.0
µA
LO
OUT
SS
CC CC
CC
V
Active Read Current
CC
I
CE# = V , OE# = V
IH
20
30
40
mA
mA
CC1
IL
(Notes 1, 2)
V
Active Program/Erase Current
CC
I
I
CE# V , OE#
= VIH
30
1
CC2
CC3
=
IL
(Notes 2, 3, 4)
V
Standby Current (Notes 2, 5)
CE# = V ± 0.5 V
5
µA
V
CC
CC
V
Input Low Level
Input High Level
–0.5
0.8
IL
V
V
0.7 x V
V + 0.3
CC
V
IH
CC
Voltage for Autoselect and Sector
Protect
V
= 5.25 V
CC
10.5
12.5
0.45
V
ID
V
Output Low Voltage
Output High Voltage
I
I
I
= 12.0 mA, V = V Min
V
V
V
V
OL
OL
OH
OH
CC
CC
V
V
= –2.5 mA, V = V Min
0.85 V
OH1
OH2
CC
CC
CC
= –100 μA, V = V Min
V
–0.4
CC
CC
CC
V
Low V Lock-out Voltage
3.2
4.2
LKO
CC
Notes for DC Characteristics (both tables):
1. The I current listed includes both the DC operating current and the frequency dependent component (at 6 MHz).
CC
The frequency component typically is less than 2 mA/MHz, with OE# at V .
IH
2. Maximum I specifications are tested with V = V .
CCmax
CC
CC
3. I active while Embedded Algorithm (program or erase) is in progress.
CC
4. Not 100% tested.
5. For CMOS mode only, I
= 20 µA max at extended temperatures (> +85°C).
CC3
Rev 2
Page 20 of 36
FT29F040B
TEST CONDITIONS
Table 6. Test Specifications
5.0 V
Test Condition
Output Load
-55
All others Unit
2.7 kΩ
1 TTL gate
100
Device
Under
Test
Output Load Capacitance, C
(including jig capacitance)
L
30
5
pF
C
L
6.2 kΩ
Input Rise and Fall Times
Input Pulse Levels
20
ns
V
0.0–3.0 0.45–2.4
Input timing measurement
reference levels
1.5
1.5
0.8, 2.0
0.8, 2.0
V
V
Note: Diodes are IN3064 or equivalent
Output timing measurement
reference levels
Figure 7. Test Setup
KEY TO SWITCHING WAVEFORMS
WAVEFORM
INPUTS
OUTPUTS
Steady
Changing from H to L
Changing from L to H
Don’t Care, Any Change Permitted
Does Not Apply
Changing, State Unknown
Center Line is High Impedance State (High Z)
Rev 2
Page 21 of 36
FT29F040B
AC CHARACTERISTICS
Read Only Operations
Parameter Symbols
Speed Options (Note 1)
JEDEC
Std
Description
Test Setup
-55
-70
-90 -120 -150 Unit
t
t
Read Cycle Time (Note 3)
Min
55
70
90
90
120
120
150
150
ns
ns
AVAV
RC
CE# = V
OE# = V
IL,
t
t
Address to Output Delay
Max
55
70
AVQV
ACC
IL
t
t
Chip Enable to Output Delay
Output Enable to Output Delay
OE# = V
Max
Max
Min
55
30
0
70
30
0
90
35
0
120
50
0
150
55
0
ns
ns
ns
ELQV
CE
IL
t
t
GLQV
OE
Read
Output Enable Hold
t
OEH
Toggle and
Data# Polling
Time (Note 3)
Min
10
18
18
0
10
20
20
0
10
20
20
0
10
30
30
0
10
35
35
0
ns
ns
ns
ns
Chip Enable to Output High Z
(Notes 2, 3)
t
t
t
Max
EHQZ
GHQZ
DF
DF
OH
Output Enable to Output High Z
(Notes 2, 3)
t
Output Hold Time from Addresses, CE#
or OE#, Whichever Occurs First
t
t
Min
AXQX
Notes:
1. See Figure 7 and Table 6 for test conditions.
2. Output driver disable time.
3. Not 100% tested.
tRC
Addresses Stable
tACC
Addresses
CE#
tDF
tOE
OE#
WE#
tOEH
tCE
tOH
HIGH Z
HIGH Z
Output Valid
Outputs
0 V
Figure 8. Read Operation Timings
Rev 2
Page 22 of 36
FT29F040B
AC CHARACTERISTICS
Erase and Program Operations
Parameter Symbols
Speed Options
-70 -90 -120
JEDEC
Std
Description
Write Cycle Time (Note 1)
Address Setup Time
Address Hold Time
-55
-150
Unit
ns
t
t
Min
Min
Min
Min
Min
Min
55
70
90
0
120
150
AVAV
WC
t
t
ns
AVWL
WLAX
DVWH
WHDX
AS
AH
DS
DH
t
t
40
25
45
30
45
45
0
50
50
50
50
ns
t
t
Data Setup Time
ns
t
t
Data Hold Time
ns
t
Output Enable Setup Time
0
ns
OES
Read Recover Time Before Write
(OE# high to WE# low)
t
t
Min
0
ns
GHWL
GHWL
t
t
CE# Setup Time
Min
Min
Min
Min
0
0
ns
ns
ns
ns
ELWL
WHEH
WLWH
WHWL
CS
CH
WP
t
t
t
CE# Hold Time
t
Write Pulse Width
Write Pulse Width High
30
35
45
20
50
50
t
t
WPH
Byte Programming Operation
(Note 2)
t
t
t
t
Typ
7
µs
WHWH1
WHWH2
WHWH1
WHWH2
Sector Erase Operation
(Note 2))
Typ
Min
1
sec
µs
t
V
Set Up Time (Note 1))
CC
50
VCS
Notes:
1. Not 100% tested.
2. See the “Erase and Programming Performance” section for more information.
Rev 2
Page 23 of 36
FT29F040B
AC CHARACTERISTICS
Program Command Sequence (last two cycles)
Read Status Data (last two cycles)
tAS
tWC
Addresses
555h
PA
PA
PA
tAH
CE#
OE#
tCH
tWHWH1
tWP
WE#
tWPH
tCS
tDS
tDH
PD
DOUT
A0h
Status
Data
VCC
tVCS
Note: PA = program address, PD = program data, D
is the true data at the program address.
OUT
Figure 9. Program Operation Timings
Erase Command Sequence (last two cycles)
Read Status Data
tAS
SA
tWC
VA
VA
Addresses
CE#
2AAh
555h for chip erase
tAH
tCH
OE#
tWP
WE#
tWPH
tWHWH2
tCS
tDS
tDH
In
Data
VCC
Complete
55h
30h
Progress
10 for Chip Erase
tVCS
Note:
SA = Sector Address. VA = Valid Address for reading status data.
Figure 10. Chip/Sector Erase Operation Timings
Rev 2
Page 24 of 36
FT29F040B
AC CHARACTERISTICS
tRC
VA
Addresses
VA
VA
tACC
tCE
CE#
tCH
tOE
OE#
WE#
tOEH
tDF
tOH
High Z
DQ7
Valid Data
Complement
Complement
True
High Z
DQ0–DQ6
Status Data
True
Valid Data
Status Data
Note: VA = Valid address. Illustration shows first status cycle after command sequence, last status read cycle, and array data
read cycle .
Figure 11. Data# Polling Timings (During Embedded Algorithms)
tRC
Addresses
CE#
VA
tACC
tCE
VA
VA
VA
tCH
tOE
OE#
WE#
tOEH
tDF
tOH
High Z
DQ6/DQ2
Valid Status
(first read)
Valid Status
Valid Status
Valid Data
(second read)
(stops toggling)
Note:
VA = Valid address; not required for DQ6. Illustration shows first two status cycle after command sequence, last status read cycle,
and array data read cycle.
Figure 12. Toggle Bit Timings (During Embedded Algorithms)
Rev 2
Page 25 of 36
FT29F040B
AC CHARACTERISTICS
Enter
Embedded
Erasing
Erase
Suspend
Enter Erase
Suspend Program
Erase
Resume
Erase
Erase Suspend
Read
Erase
Suspend
Program
Erase
Complete
WE#
Erase
Erase Suspend
Read
DQ6
DQ2
DQ2 and DQ6 toggle with OE# and CE#
Note: Both DQ6 and DQ2 toggle with OE# or CE#. See the text on DQ6 and DQ2 in the section “Write Operation Status” for more
information.
Figure 13. DQ2 vs. DQ6
Rev 2
Page 26 of 36
FT29F040B
AC CHARACTERISTICS
Erase and Program Operations
Alternate CE# Controlled Writes
Parameter Symbols
Speed Options
-70 -90 -120
JEDEC
Std
Description
Write Cycle Time (Note 1))
Address Setup Time
Address Hold Time
-55
-150
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
t
t
Min
Min
Min
Min
Min
Min
Min
Min
Min
Min
55
70
90
0
120
150
AVAV
AVEL
ELAX
DVEH
EHDX
WC
t
t
AS
AH
DS
DH
t
t
40
25
45
30
45
45
0
50
50
50
50
t
t
Data Setup Time
t
t
Data Hold Time
t
t
t
Read Recover Time Before Write
CE# Setup Time
0
GHEL
GHEL
t
0
WLEL
WS
WH
t
t
CE# Hold Time
0
EHWH
t
t
Write Pulse Width
30
20
35
20
45
20
50
20
50
20
ELEH
EHEL
CP
t
t
Write Pulse Width High
CPH
Byte Programming Operation
(Note 2))
t
t
t
t
Typ
Typ
7
1
µs
WHWH1
WHWH2
WHWH1
WHWH2
Sector Erase Operation
(Note 2))
sec
Notes:
1. Not 100% tested.
2. See the “Erase and Programming Performance” section for more information.
Rev 2
Page 27 of 36
FT29F040B
AC CHARACTERISTICS
555 for program
PA for program
2AA for erase
SA for sector erase
555 for chip erase
Data# Polling
Addresses
PA
tWC
tWH
tAS
tAH
WE#
OE#
tGHEL
tWHWH1 or 2
tCP
CE#
Data
tWS
tCPH
tDS
tBUSY
tDH
DQ7#
DOUT
tRH
A0 for program
55 for erase
PD for program
30 for sector erase
10 for chip erase
Notes:
1. PA = Program Address, PD = Program Data, SA = Sector Address, DQ7# = Complement of Data Input, D
= Array Data.
OUT
2. Figure indicates the last two bus cycles of the command sequence.
Figure 14. Alternate CE# Controlled Write Operation Timings
Rev 2
Page 28 of 36
FT29F040B
ERASE AND PROGRAMMING PERFORMANCE
Typ
Max
Parameter
Sector Erase Time
(Note 1) (Note 2) Unit
Comments
1
8
8
sec
sec
µs
Excludes 00h programming prior to erasure (Note 4)
Chip Erase Time
64
Byte Programming Time
Chip Programming Time (Note 3)
7
300
10.8
Excludes system-level overhead (Note 5)
3.6
sec
Notes:
1. Typical program and erase times assume the following conditions: 25°C, 5.0 V V , 1,000,000 cycles. Additionally,
CC
programming typicals assume checkerboard pattern.
2. Under worst case conditions of 90°C, V = 4.5 V (4.75 V for -55), 1,000,000 cycles.
CC
3. The typical chip programming time is considerably less than the maximum chip programming time listed, since most bytes
program faster than the maximum byte program time listed. If the maximum byte program time given is exceeded, only then
does the device set DQ5 = 1. See the section on DQ5 for further information.
4. In the pre-programming step of the Embedded Erase algorithm, all bytes are programmed to 00h before erasure.
5. System-level overhead is the time required to execute the four-bus-cycle command sequence for programming. See Table 4
for further information on command definitions.
6. The device has a guaranteed minimum erase and program cycle endurance of 1,000,000 cycles.
LATCHUP CHARACTERISTICS
Min
Max
+ 1.0 V
Input Voltage with respect to V on all I/O pins
–1.0 V
V
CC
SS
V
Current
–100 mA
+100 mA
CC
Includes all pins except V . Test conditions: V = 5.0 V, one pin at a time.
CC
CC
TSOP PIN CAPACITANCE
Parameter Symbol
Parameter Description
Input Capacitance
Test Setup
= 0
Typ
6
Max
Unit
pF
C
V
V
V
7.5
12
9
IN
IN
C
Output Capacitance
= 0
8.5
7.5
pF
OUT
OUT
C
Control Pin Capacitance
= 0
IN
pF
IN2
Notes:
1. Sampled, not 100% tested.
2. Test conditions T = 25°C, f = 1.0 MHz.
A
Rev 2
Page 29 of 36
FT29F040B
PLCC AND PDIP PIN CAPACITANCE
Parameter Symbol
Parameter Description
Test Setup
= 0
Typ
4
Max
6
Unit
pF
C
Input Capacitance
V
V
V
IN
IN
C
Output Capacitance
Control Pin Capacitance
= 0
8
12
12
pF
OUT
OUT
C
= 0
PP
8
pF
IN2
Notes:
1. Sampled, not 100% tested.
2. Test conditions T = 25°C, f = 1.0 MHz.
A
DATA RETENTION
Parameter
Test Conditions
150°C
Min
Unit
10
20
Years
Years
Minimum Pattern Data Retention Time
125°C
Rev 2
Page 30 of 36
FT29F040B
PHYSICAL DIMENSIONS
PD 032—32-Pin Plastic DIP
Dwg rev AD; 10/99
Rev 2
Page 31 of 36
FT29F040B
PHYSICAL DIMENSIONS (continued)
PL 032—32-Pin Plastic Leaded Chip Carrier
Dwg rev AH; 10/99
Rev 2
Page 32 of 36
FT29F040B
PHYSICAL DIMENSIONS (continued)
TS 032—32-Pin Standard Thin Small Package
Dwg rev AA; 10/99
Rev 2
Page 33 of 36
FT29F040B
PHYSICAL DIMENSIONS (continued)
TSR032—32-Pin Reversed Thin Small Outline Package
Dwg rev AA; 10/99
Rev 2
Page 34 of 36
32 Lead Cerquad "K" (CQ032)
Rev 2
Page 35 of 36
32 Lead Cerquad "K" Lid (CQ032L)
Rev 2
Page 36 of 36
相关型号: