TC-48DD-J-V05-F-S-A [FOTEK]

Temperature Controller;
TC-48DD-J-V05-F-S-A
型号: TC-48DD-J-V05-F-S-A
厂家: FOTEK CONTROLS CO., LTD.    FOTEK CONTROLS CO., LTD.
描述:

Temperature Controller

文件: 总5页 (文件大小:1917K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
With Cold Junction Compensation,  
Suited to Operated at -20 C ~ +60 C  
All type with Sensor Break Alarm LED.  
With P+D Control to Control Temperature Easily.  
High Accuracy of Displaying & Setting  
Less than 0.5% of F.S.  
With Stand-by/Over-heat Alarm.( Optioned ).  
With Heater Break Alarm.( Optioned ).  
-20 C ~ +60 C  
P+D  
0.5%  
(
(
)
)
Guiding of Model  
Ex. TC - 4896 D A - PT - R 3 - F - S - A  
1
2
3
4
5
6 7 8 9 10  
7 Range of Setting  
Product  
1
2
TC = Temperature Controller  
Digital Switch  
Trimmer  
Outline  
0 = -99 ~ + 99  
1 = 0 ~ +199  
3 = 0 ~ +399  
5 = 0 ~ +599  
9 = 0 ~ +999  
11 = 0 ~ +1199  
05 = -50 ~ +50  
1 = 0 ~ +100  
2 = 0 ~ +200  
4 = 0 ~ +400  
6 = 0 ~ +600  
12 = 0 ~ +1200  
48 = 48(W) X 48(H) mm X mm  
4896 = 48(W) X 96(H) mm X mm  
72 = 72(W) X 72(H) mm X mm  
96 = 96(W) X 96(H) mm X mm  
Method of Setting  
3
4
Unit of Degree  
8
9
D = Digital Swith  
A = Trimmer  
F
= F  
non = C  
Method of Display  
Method of Control  
A = Analog Deviation Meter  
D = Digital LED Display  
N = Without Display  
S
= ON/OFF  
non = P+D ON/OFF  
Type of Sensor  
10  
Alarm  
5
6
A
= With Stand-by / Over Heat Alarm  
PT = RTD PT-100  
J = J Type Thermocouple  
Non = K Type Thermocouple  
AH = With Stand-by / Over Heat Alarm  
& Heater Break Alarm  
Non = Without Alarm  
Method of Output  
R = Relay (5A/250VAC)  
V = Voltage (20mA/12V)  
L = Linear (4~20mA)  
9
Sensor Type  
K < CA > , J < IC > or PT-100  
Relay< 5A / 250VAC >,Voltage < 20mA / 12V >,Linear < 4~20mA >  
P+D ON/OFF , ON/OFF or Proportion  
Output Method  
Control Method  
Proportion Band  
Cycle Time  
General Data  
Appro 2.5% of F.S.  
2 Sec or 20 Sec < ON+OFF >  
Trimmer , Range 10  
Manual Reset  
Unit of Degree  
C or F  
Setting Method  
Setting Range  
Output Method  
Trimmer ( AL )  
0 ~ +50 , 0 ~ -50 or -50 ~ +50 of Setting Value  
Relay , 0.5A/250VAC  
AL Alarm  
Al  
Setting Method  
Setting Range  
Output Method  
Trimmer (HB)  
HB Alarm  
Hb  
0.5A~25A ; 1.0A~50A  
Relay , 0.5A/250VAC  
Power Supply  
110 / 220 VAC 20% 50 / 60Hz  
2.5VA max.  
Current Consumption  
Electrical  
Data  
Insulation Resistance  
Dielectrical Strength  
Over 50M /500 VDC Between Power And Another Terminal  
Over 2.5KV / 1min Between Power And Another Terminal  
Operating Temp./Hum  
Vibration Resistance  
Panel Thickness  
-20 C ~+60 C ; 35%~85% RH  
10~55Hz / 1.5mm , 2Hrs in X.Y.Z Direction  
1.0~8.0mm  
Mechanical  
Data  
Attachment  
CT provided with Heater Break Alarm type only.  
7.5  
CT  
5.8  
25.0  
3.5  
2
3.0  
21.0  
30.0  
40.0  
10.0  
10  
Model  
TC-4896-DA- - -A TC-4896-DA- - -AH  
TC-4896-DA-  
-
DIN48 X 96  
Non  
Alarm  
AL Alarm  
AL+HB  
Analog Deviation Meter  
1.0% of F.S.  
Method  
Tolerance  
Range  
+
40  
-
Digital Switch < 3 Digits >  
Method  
Tolerance  
Range  
0.5% of Setting Range  
-99~+99 , 0~199 , 0~399 , 0~599 , 0~999  
Dimension & Fixed Hole/  
( Thickness 1~8mm )  
Outline  
Fixed Hole  
Single Cutout Multi Juxtaposed Cutout  
91.5  
91.5  
96.0  
9.0  
7.0  
L
100.0  
48.0  
44.5  
L=48N-4.0  
N
L
2
3
4
5
6
92.0 140.0 -188.0 236.0 284.0  
11  
Control Output  
ON/OFF LED Turn to Green Color , Control Output Turn ON.  
ON/OFF LED Turn to Red Color , Control Output Turn OFF.  
but , Linear Output Type That ON/OFF LED Turn to Green Color.  
( )  
Sensor Break Alarm SB  
SB LED Turn ON when Sensor Break.  
SB  
Stand-by/Over-heat Alarm (AL)  
SV = Setting Value  
AV1/AV2 = Stand-by/Over-heat Value  
DIP Switch to Select Function  
on Inner PC Board  
DIP  
Stand-by Alarm  
Over-heat Alarm  
Stand-by/ Over-heat Alarm  
Heater Break Alarm (HB)  
Heater Break Alarm Output Turns ON when the Current of Heater Lower than Setting Value that may set at  
Front Panel. ( 0.5A~25A standard/1.0A~50A Optioned )  
0.5A~25A  
1.0A~50A  
19  
Illustration/  
P+D ON/OFF  
SV  
SV  
( )  
ON/OFF S  
PV  
SV  
Process Value  
PV  
SV  
Proportion  
SV  
Process Value  
PV  
SV  
20  

相关型号:

TC-48DD-J-V05-F-S-AH

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V1-F-S-A

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V1-F-S-AH

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V11-F-S-A

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V11-F-S-AH

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V12-F-S-A

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V2-F-S-A

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V2-F-S-AH

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V3-F-S-A

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V3-F-S-AH

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V4-F-S-A

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK

TC-48DD-J-V5-F-S-A

Temperature Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FOTEK