FGM-302PGSR [FUJIKURA]

Sensing element Gauge; 敏感元件测量仪
FGM-302PGSR
型号: FGM-302PGSR
厂家: FUJIKURA LTD.    FUJIKURA LTD.
描述:

Sensing element Gauge
敏感元件测量仪

仪表
文件: 总5页 (文件大小:255K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Sensing elementGauge  
FGM Data sheet  
Features  
Surface mount package  
Ordering Information  
FGM-6 07P G SR  
Terminal leads configuration  
Surface mount package  
Model  
Length of the pressure port  
Pressure type  
GGauge Pressure  
Rated Pressure  
(PSI)  
33mm  
66mm  
Weight  
Weight  
(grams)  
(grams)  
0.3  
0.35  
Measurable pressure  
range(kPa)  
Part number  
3mm pressure port  
6mm pressure port  
FGM-602PGSR  
FGM-605PGSR  
FGM-607PGSR  
FGM-615PGSR  
FGM-630PGSR  
FGM-650PGSR  
FGM-670PGSR  
FGM-6120PGSR  
-13.79 to 13.79  
-34.47 to 34.47  
-48.26 to 48.26  
-98.07 to 103.4  
-98.07 to 206.8  
-98.07 to 344.7  
-98.07 to 482.6  
-98.07 to 827.4  
FGM-302PGSR  
FGM-305PGSR  
FGM-307PGSR  
FGM-315PGSR  
FGM-330PGSR  
FGM-350PGSR  
FGM-370PGSR  
FGM-3120PGSR  
RoHS compliance  
Specifications  
Model  
02PG  
05PG  
07PG  
15PG  
30PG  
50PG  
70PG  
120PG  
Unit  
Recommended operating conditions  
Pressure type  
Gauge pressure  
-
Rated pressure  
13.79  
34.47  
48.26  
103.4  
206.8  
344.7  
482.6  
827.4  
kPa  
-13.79  
-34.47  
-48.26  
-98.07  
-98.07  
-98.07  
-98.07  
-98.07  
Measurable pressure range  
kPa  
to 13.79 to 34.47 to 48.26 to 103.4 to 206.8 to 344.7 to 482.6 to 827.4  
Temperature range  
Pressure media  
Excitation current (Constant)  
Absolute maximum rating  
0 to 50  
deg.C  
-
mADC  
Non-corrosive gases only (No liquid)  
1.5  
1.5 times  
of rating  
pressure  
Twice of rated pressure  
Maximum load pressure  
-
Maximum excitation current  
Operating temperature  
Storage temperature  
Operating humidity  
3.0  
-20 to 100  
-40 to 120  
mADC  
deg.C  
deg.C  
%RH  
30 to 80 (Non dew condition)  
Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C)  
Output span voltage  
60 to 140 (at 0kPa to rated pressure)  
mV  
mV  
msec.  
%FS/0-  
Offset voltage  
Bridge resistance  
Response time  
+/-20 (at 0kPa)  
4000 to 6000  
2 (for the reference)  
+/-5  
Accuracy  
TSO*  
TCS*  
50deg.C  
2.5  
Linearity  
Pressure hysteresis  
+/-0.5  
+/-0.4  
+/-0.3  
+/-0.2  
+/-0.5  
+/-0.6  
%FS  
%FS  
+/-0.4  
*TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C)  
*TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C)  
1
Sensing elementGauge  
FGM Data sheet  
P1= 0 kPa  
T1= 0 deg.C  
P2= 1/2 x P3 (kPa)  
P3= reted pressure (kPa)  
T2= 25 deg.C  
T3= 50 deg.C  
Offset voltage (mV)  
Voff = V(P1,T)  
Voff(0) = V(P1,T1)  
Voff(25) = V(P1,T2)  
Voff(50) = V(P1,T3)  
Output voltage at full scale (mV)  
Vfs = V(P3,T)  
Vfs(0) = V(P3,T1)  
Vfs(25) = V(P3,T2)  
Vfs(50) = V(P3,T3)  
Output span voltage (mV)  
SV = Vfs - Voff  
SV(0) = Vfs(0) - Voff(0)  
SV(25) = Vfs(25) - Voff(25)  
SV(50) = Vfs(50) - Voff(50)  
Temperature sensitivity of offset voltage (%FS)  
TSO = {LARGER ONE} / SV(25) x 100  
LARGER ONE = larger absolute value which of {Voff(0)-Voff(25)} and {Voff(50)-Voff(25)}  
Temperature coefficient of output span voltage (%FS)  
TCS = {max[SV(0),SV(25),SV(50)] - min[SV(0),SV(25),SV(50)] } / SV(25) x 100  
Linearity (%FS)  
NL = {V(P2,T2) - [Voff(25)+Vfs(25)]/2 } / SV(25) x 100  
Pressure hysteresis (%FS)  
Phys = {Voff’(25) - Voff(25) } / SV(25) x 100  
Voff’(25) : Output voltage against P1 after stressing by P3 pressure.  
2
Sensing elementGauge  
FGM Data sheet  
Outline dimensions■  
2-φ1.1  
3
Sensing elementGauge  
FGM Data sheet  
Connection diagram■  
Output characteristics■  
302PG307PG>  
602PG607PG>  
315PG3120PG>  
615PG6120PG>  
Output voltagemV)  
Output voltagemV)  
Output span  
voltage  
Output span  
voltage  
Offset voltage  
-Rated pressure  
Offset voltage  
-98.07kPa  
0kPa  
0kPa  
Rated pressure  
Rated pressure  
PressurekPa)  
PressurekPa)  
Atomospheric  
pressure  
Atomospheric  
pressure  
Note ;  
Please read instruction “Notes” before using the sensor.  
Fujikura reserves the right to change specifications without notice.  
Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag.  
If the sensors expose to an atmosphere, the pins will be black by sulfuration.  
Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress  
such as mounting, installation and etc. over longtime using.  
4
Sensing elementGauge  
FGM Data sheet  
Reflow Soldering process recommendation profile  
Package  
Surface  
Temperature  
(Degree C)  
230  
210  
150  
Room  
Temp.  
Time  
a
b
c
d
e
a: Rump up rate  
b: Pre-heating  
c: Rump up rate  
d: Heating  
1 or 2 deg.C/sec.  
150 to 180 deg.C,within 60 to120sec.  
1 to 2 deg.C/sec.  
max.230 deg.C,max.10sec. 210 deg.C,within 30sec.  
1 or 2 deg.C/sec.  
e: Rump down rate  
Note ;  
1 ) Temperature means Surface temperature of the sensor package.  
2 ) Reflow process max. 2 times.  
3 ) Do not wash the sensor.  
4 ) Do not put the solder and flux on the sensor package.  
If you have any questions regarding technical issues or specifications, please contact us.  
Fujikura Ltd. Sensor Department  
Phone +81-(0)3-5606-1072  
5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan  
E-mail : sensor@fujikura.co.jp  
5

相关型号:

FGM-305PGSR

Sensing element Gauge
FUJIKURA

FGM-307PGSR

Sensing element Gauge
FUJIKURA

FGM-3120PGSR

Sensing element Gauge
FUJIKURA

FGM-315PGSR

Sensing element Gauge
FUJIKURA

FGM-330PGSR

Sensing element Gauge
FUJIKURA

FGM-350PGSR

Sensing element Gauge
FUJIKURA

FGM-370PGSR

Sensing element Gauge
FUJIKURA

FGM-602PGSR

Sensing element Gauge
FUJIKURA

FGM-605PGSR

Sensing element Gauge
FUJIKURA

FGM-607PGSR

Sensing element Gauge
FUJIKURA

FGM-6120PGSR

Sensing element Gauge
FUJIKURA

FGM-615PGSR

Sensing element Gauge
FUJIKURA