FPOW-08G [FUJIKURA]

Unit/Water level sensor; 单位/水位传感器
FPOW-08G
型号: FPOW-08G
厂家: FUJIKURA LTD.    FUJIKURA LTD.
描述:

Unit/Water level sensor
单位/水位传感器

传感器
文件: 总2页 (文件大小:95K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Unit/Water level sensor  
FPOW Data sheet  
Features  
Applications  
Boiler  
Industrial instrumentation  
.
.
.
.
.
.
Positive and negative water pressure measurable  
Volt level output  
Piggy-back style, pre-amplified and pre-compensated module  
Pre-calibration of offset voltage and span  
Part number for ordering  
FPOW - 08 G  
Pressure type  
G : Gauge (Bipolar pressure)  
Model  
FPOW  
Rated pressure (PSI)  
Pressure type  
Gauge pressure  
FPOW  
Model  
Package configuration  
Outer housing encapsulated sensor unit  
Measurable pressure range (kPa)  
29.4 49.0  
Part number for ordering  
FPOW-08G  
Specifications  
Model/Rated pressure  
08G  
Unit  
Recommended operating conditions  
Pressure type  
Gauge pressure  
29.4 49.0  
0.3 0.5  
kPa  
kg/cm2  
kPa  
Rated pressure  
Measurable pressure range  
Pressure media  
29.4 49.0  
Bath water (including bath fragrance)  
5.0  
Excitation voltage  
VDC  
Absolute maximum rating  
Positive pressure  
Negative pressure  
196  
98  
kPa  
kPa  
Maximum load pressure  
Maximum excitation voltage  
Operating temperature  
Storage temperature  
12  
20  
40  
VDC  
60  
80  
Operating humidity  
30 80 (No dew condensation)  
RH  
Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25  
)
Current consumption  
Mechanical response time  
Output voltage  
less than 10  
5 (For the reference)  
0.3( 29.4kPa) 3.5(49.0kPa)  
mA  
msec  
V
Full scale span voltage  
Offset voltage  
Temperature sensitivity of offset(TSO)  
Temperature coefficient of sensitivity(TCS)  
3.2 0.1  
1.5 0.1  
2.5  
V
V
FS/0 50  
FS/0 50  
2.5  
1
Unit/Water level sensor  
FPW Data sheet  
Outline dimensions  
unit(mm)  
FPW  
Note ; Please read instruction “Notes” before using the sensor.  
Fujikura reserves the right to change specifications without notice.  
If you have any questions regarding technical issues or specifications, please contact us.  
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan  
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538  
2
E-mail : sensor@fujikura.co.jp  

相关型号:

FPP-01

AC Filter for PCB Mounting Cots Optimized Standard- or Medical-Filter
SCHURTER

FPP-02

AC Filter for PCB Mounting in Flat Housing
SCHURTER

FPP-11-K

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FPP-11-K/Q

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FPP-11-L

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FPP-11-L/Q

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FPP-11-P

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FPP-11-P/Q

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FPP-11-R

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FPP-11-R/Q

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FPP-12-K

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FPP-12-K/Q

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM