POWER RELAY  
1 POLE—10 A LOW PROFILE TYPE  
FTR-H1 SERIES  
RoHS compliant  
n FEATURES  
l Working class: B (for IMQ)/ C (for VDE)  
l Type of service: continuous duty  
l Low profile (height 16.5 mm)/ cadmium free contacts  
l 1 form A/ 1 form C 10 A, TV-5 rating available  
l UL class B (130°C) insulation  
l High isolation in small package (between coil and con-  
tacts)  
—Insulation distance : 8 mm  
—Dielectric strength : 5,000 VAC  
—Surge strength  
l Plastic materials  
UL CTI level class 2  
l Plastic sealed relay  
:10,000 V  
—UL94 flame class V-0  
l Pin configuration compatible to VS/ FBR610 Series  
l UL, CSA, BSI, VDE, SEMKO recognized  
l Conforms to FIMKO, DEMKO  
l Environmentally friendly cadmium free contacts type are  
available  
l RoHS compliant since date code: 0434R  
Please see page 7 for more information  
n ORDERING INFORMATION  
FTR-H1  
A
A
005  
V
– **  
(f)  
[Example]  
(a)  
(b) (c) (d) (e)  
(a)  
(b)  
Series Name  
FTR-H1: FTR-H1 Series  
Contact Arrangement  
A
C
: 1 form A (SPST-NO)  
: 1 form C (SPDT)  
(c)  
(d)  
Coil Type  
A
D
: Standard type (0.53 W)  
: High sensitive type (0.4W)  
Nominal Voltage  
005  
006  
009  
: 5 VDC  
: 6 VDC  
: 9 VDC  
012  
024  
048  
: 12 VDC  
: 24 VDC  
: 48 VDC  
(e)  
Contact Material/TV Type  
V
T
: Gold plate silver alloy (standard type)  
: Gold plate silver alloy (TV-5 rating type, 1 form A standard type  
only)  
(f)  
Custom Designation  
Custom specificationto be assigned  
Actual Marking  
H1AA005V  
Ordering Code  
FTR-H1AA005V  
1
FTR-H1 SERIES  
n SAFETY STANDARD AND FILE NUMBERS  
UL508, 873 (File No. E63614)  
C22.2 No. 14 (File No. LR40304-30/LR107822)  
VDE 0435, 0631, 0700, 0860 (File No. 11039-4940-1019)  
Nominal voltage  
Contact rating  
TV-Rating  
General  
5 ~ 48 VDC  
TV-5 120 VAC  
1/2 HP 250 VAC 1/3 HP 125 VAC  
10 A 30 VDC/250 VAC resistive  
Pilot duty B 300, Q 300  
1/2 HP 250 VAC 1/3 HP 125 VAC  
10 A 30 VDC/250 VAC resistive  
3A 250 VAC inductive (PF=0.4)  
Pilot duty B 300, Q 300  
2
FTR-H1 SERIES  
n SPECIFICATIONS  
Item  
Standard Type  
Sensitive  
TV-5 Rating Type  
Contact  
Arrangement  
1 form A (SPST-NO), 1 form C (SPDT)  
Gold plate silver alloy  
Single  
1 form A (SPST-NO)  
Material  
Style  
(at 1 A 6 VDC)  
Resistance (initial)  
Rating (Resistive)  
Maximum Carrying Current  
Maximum Switching Rating  
Maximum 100 m  
10 A 250 VAC/30 VDC  
14 A  
2,500 VA/300 W  
Maximum Switching Voltage 400 VAC 300 VDC  
Maximum Switching Current 10 A  
Minimum Switching Load*1  
Maximum Inrush Current  
Operating Range  
10 mA 5 VDC  
78 A 120 VAC (at lamp load)  
Coil  
80 to 110 % × V nominal  
0.53 W  
Nominal Power (at 20°C)  
Operate Power (at 20°C)  
Operating Temperature  
0.4W  
0.53 W  
0.26W  
0.26 W  
0.225W  
–40°C to +75°C (no frost) (refer to the CHARACTERISTIC DATA)  
Time Value Operate (at nominal voltage) Maximum 10 ms  
Release (at nominal voltage) Maximum 5 ms  
Minimum 1,000 M  
Insulation  
Resistance (at 500 VDC)  
Dielectric Between open contacts  
1,000 VAC 1 minute  
Strength  
2
Between coil and contacts  
*
5,000 VAC 1 minute  
Surge Strength*3  
10,000 V (at 1.2 x 50 µs)  
2 × 107 operations minimum  
Life  
Mechanical  
Electrical  
Contact Rating 1 × 105 operations minimum  
2.5 x 104 ops. minimum  
Lamp Load  
Misoperation  
Endurance  
Misoperation  
Endurance  
Other  
Vibration  
10 to 55 Hz (double amplitude of 1.65 mm)  
10 to 55 Hz (double amplitude of 3.3 mm)  
100 m/s 2 (11 ±1 ms)  
Resistance  
Shock  
Resistance  
1,000 m/s 2 (6 ±1 ms)  
Weight  
Approximately 12 g  
1
*
Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load  
before production since reference values may vary according to switching frequencies, environmental conditions and ex-  
pected reliability levels.  
IMQ  
IMQ  
2
*
*
3
3
FTR-H1 SERIES  
n COIL DATA CHART  
MODEL  
Nominal  
Voltage  
Coil Resistance Must Operate Must Release  
(±10%)  
Voltage  
Voltage  
Standard Type  
TV-5 Rating Type  
FTR-H1 (C, A) A005 V  
FTR-H1 (C, A) A006V  
FTR-H1 (C, A) A009 V  
FTR-H1 (C, A) A012 V  
FTR-H1 (C, A) A024 V  
FTR-H1 (C, A) A048 V  
FTR-H1AA005 T  
FTR-H1AA006 T  
FTR-H1AA009 T  
FTR-H1AA012 T  
FTR-H1AA024 T  
FTR-H1AA048 T  
5 VDC  
6 VDC  
47 Ω  
68 Ω  
3.5 VDC  
4.2 VDC  
6.3 VDC  
8.4 VDC  
16.8 VDC  
33.6 VDC  
0.5 VDC  
0.6 VDC  
0.9 VDC  
1.2 VDC  
2.4 VDC  
4.8 VDC  
9 VDC  
155 Ω  
12 VDC  
24 VDC  
48 VDC  
270 Ω  
1,100 Ω  
4,400 Ω  
Note: All values in the table are measured at 20°C.  
Sensitive Type  
MODEL  
Nominal  
Voltage  
Coil Resistance Must Operate Must Release  
(±10%)  
Voltage  
Voltage  
Standard Type  
FTR-H1 (C, A) D005 V  
FTR-H1 (C, A) D006 V  
FTR-H1 (C, A) D009V  
FTR-H1 (C, A) D012 V  
FTR-H1 (C, A) D024 V  
FTR-H1 (C, A) D048 V  
5 VDC  
6 VDC  
62 Ω  
90 Ω  
3.75 VDC  
4.5 VDC  
0.5 VDC  
0.6 VDC  
0.9 VDC  
1.2 VDC  
2.4 VDC  
4.8 VDC  
9 VDC  
202 Ω  
6.75 VDC  
9.0 VDC  
12 VDC  
24 VDC  
48 VDC  
360 Ω  
1,440 Ω  
5,760 Ω  
18.0 VDC  
36.0 VDC  
Note: All values in the table are measured at 20°C.  
4
FTR-H1 SERIES  
n CHARACTERISTIC DATA  
Timing  
Coil temperature rise  
Timing  
20  
16  
100  
20  
80  
14A  
15  
10A  
12  
8
60  
10  
Operate  
Operate  
40  
0A  
5
4
0
20  
Release  
0.4  
Release  
0
0.6  
0.8  
1.0  
1.2  
0.2  
0.6  
0.8  
1.0  
1.2  
0.2  
0.4  
0
0.2  
0.4  
0.6  
0.8  
1.2  
1.0  
Coil power (W)  
Coil power (W)  
Coil power (W)  
Operating range  
Operating range  
Maximum Switching Power  
20  
10  
5
2.4  
2.2  
2.0  
1.8  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
2.4  
2.2  
2.0  
1.8  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
FTR- ( ) A  
FTR-H1  
FTR- ( ) D  
AC Resistive  
0 A  
0 A  
10 A  
10 A  
2
1
DC Resistive  
0.5  
0.2  
Must operate voltage (hot coil)  
Must operate voltage (cool coil)  
0
20  
40  
60  
80  
100  
0
20  
40  
60  
80  
100  
10  
20  
50  
100 200  
500  
Ambient temperature (°C)  
Ambient temperature (°C)  
Contact Voltage (V)  
Life Curve  
100  
50  
AC250 V  
DC30 V  
FTR-H1  
AC250V COS ø=0.7  
DC30 V t=7ms  
20  
10  
5
AC250V COS ø=0.4  
DC30 V t=15ms  
0
4
6
8
10  
2
12  
Contact load current (A)  
5
FTR-H1 SERIES  
n REFERENCE DATA  
Distribution of contact resistance  
Distribution of operate and release time  
Distribution of operate and release voltage  
100  
100  
100  
Operate  
Release  
Operate  
Make  
80  
60  
40  
20  
80  
Release  
80  
60  
40  
20  
Break  
60  
40  
20  
0
1
2
3
4
5
6
7
8
0
2
4
12  
14  
6
8
10  
0
10  
20  
30 40  
50 60 70 80  
Time (ms)  
Contact resistance (m  
)
Nominal voltage multiplying factor (%)  
Mechanical life test  
Electrical life test  
Electrical life test  
10  
8
10  
8
10  
8
Operate  
Operate  
Operate  
Release  
6
6
6
4
4
4
Release  
Release  
5
5
5
5
5
5
5
5
5
5
2
2
2
0
0
0
FTR-HICA012V  
n=10  
10 OP./Min.  
FTR-HICA012V  
n=10  
FTR-HICA012V  
n=10  
10 Operations/minute  
DC30V, 0 A (resistive)  
500  
200  
500  
200  
100  
50  
20  
10  
5
500  
1200 OP./Min.  
200  
100  
50  
20  
10  
5
AC250 V, 10A (Resistive)  
100  
50  
20  
10  
5
Break  
Make  
Break  
Make  
5
5
Break  
Make  
5
5
5
5
5
5
5
5
5
5
5
10  
2
2
2
10  
100  
200  
500  
1000  
2000  
Initial  
Initial  
Operation (x104)  
Operation (x104)  
Operation (x104)  
n DIMENSIONS  
l
Dimensions  
l
Schematics  
n
PC board mounting  
hole layout  
(BOTTOM VIEW)  
(BOTTOM VIEW)  
FTR-H1A type  
28.0+0.3  
12.8+0.3  
1
2
3
4-ø1.3  
COM  
0.4  
0.2  
3.5  
0.3  
7.5  
1.0  
0.9  
NO  
5
(2.1)  
(2.65)  
20.0  
(2.1)  
3.5  
20.0  
FTR-H1C type  
28.0+0.3  
12.8+0.3  
5-ø1.3  
1
2
COM  
NO  
NC  
5
4
3
(2.1)  
3.5  
3.5  
0.4  
0.2  
20.0  
0.2  
3.5  
0.9  
0.3  
7.5  
1.0  
(2.65)  
3.5  
(2.1)  
Unit: mm  
20.0  
6
FTR-H1 SERIES  
RoHS Compliance and Lead Free Relay Information  
1. General Information  
l
Relays produced after the specific date code that is indicated on each data sheet are lead-free  
now. Most of our signal and power relays are lead-free. Please refer to Lead-Free Status Info.  
(http://www.fujitsu.com/us/downloads/MICRO/fcai/relays/lead-free-letter.pdf)  
Lead free solder paste currently used in relays is Sn-3.0Ag-0.5Cu.  
All signal and most power relays also comply with RoHS. Please refer to individual data  
sheets. Relays that are RoHS compliant do not contain the 5 hazardous materials that  
are restricted by RoHS directive (lead, mercury, chromium IV, PBB, PBDE).  
It has been verified that using lead-free relays in leaded assembly process will not cause any  
problems (compatible).  
l
l
l
l
l
l
“LF” is marked on each outer and inner carton. (No marking on individual relays).  
To avoid leaded relays (for lead-free sample, etc.) please consult with area sales office.  
We will ship leaded relays as long as the leaded relay inventory exists.  
Note: Cadmium was exempted from RoHS on October 21, 2005. (Amendment to Directive 2002/95/EC)  
2. Recommended Lead Free Solder Profile  
l
Recommended solder paste Sn-3.0Ag-0.5Cu.  
Reflow Solder condtion  
Flow Solder condtion:  
Pre-heating:  
Soldering:  
maximum 120˚C  
dip within 5 sec. at  
260˚C soler bath  
Solder by Soldering Iron:  
Soldering Iron  
Temperature: maximum 360˚C  
Duration:  
maximum 3 sec.  
We highly recommend that you confirm your actual solder conditions  
3. Moisture Sensitivity  
Moisture Sensitivity Level standard is not applicable to electromechanical realys.  
4. Tin Whisker  
l
Dipped SnAgCu solder is known as low risk tin whisker. No considerable length whisker was found by our in  
house test.  
7
FTR-H1 SERIES  
Fujitsu Components International Headquarter Offices  
Japan  
Europe  
Fujitsu Component Limited  
Gotanda-Chuo Building  
3-5, Higashigotanda 2-chome, Shinagawa-ku  
Tokyo 141, Japan  
Fujitsu Components Europe B.V.  
Diamantlaan 25  
2132 WV Hoofddorp  
Netherlands  
Tel: (81-3) 5449-7010  
Tel: (31-23) 5560910  
Fax: (81-3) 5449-2626  
Fax: (31-23) 5560950  
Email: promothq@ft.ed.fujitsu.com  
Web: www.fcl.fujitsu.com  
Email: info@fceu.fujitsu.com  
Web: http://www.fujitsu.com/emea/services/components/  
North and South America  
Asia Pacific  
Fujitsu Components America, Inc.  
250 E. Caribbean Drive  
Sunnyvale, CA 94089 U.S.A.  
Tel: (1-408) 745-4900  
Fujitsu Components Asia Ltd.  
102E Pasir Panjang Road  
#04-01 Citilink Warehouse Complex  
Singapore 118529  
Fax: (1-408) 745-4970  
Tel: (65) 6375-8560  
Email: marcom@fcai.fujitsu.com  
Web: http://www.fujitsu.com/us/services/edevices/components/  
Fax: (65) 6273-3021  
Email: fcal@fcal.fujitsu.com  
Web: http://www.fujitsu.com/sg/services/micro/components/  
©2005 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the property off their respective  
owners.  
Fujitsu Components America does not warrant that the content of datasheet is error free. In a continuing effort to improve our products Fujitsu  
Components America, Inc. reserves the right to change specifications/datasheets without prior notice. Rev. 11/18/2005.  

相关型号:

FTR-H1AA048VRG

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD005T

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD005TRG

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD005V

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD005VRG

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD006T

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD006TRG

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD006V

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD006VRG

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD009T

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD009TRG

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU

FTR-H1AD009V

POWER RELAY 1 POLE-10 A LOW PROFILE TYPE
FUJITSU