ULTRASONIC FLOWMETER  
(2-Path System type)  
DATA SHEET  
FSH, FSG, FSD  
This flowmeter is a fixed type ultrasonic flowmeter based  
on transit-time measuring method.  
The flowmeter is a compact and light-weight instrument  
incorporating the latest electronics and high speed digital  
signal processing technologies, realizing high performance  
and easy operation. This high performance flowmeter is  
used for 2-path system only.  
FEATURES  
1. Compact and light-weight  
Flow transmitter  
(FSH)  
Thanks to the adoption of the latest electronics the  
flow transmitter size and mass are 1/2 of our traditional  
instrument.  
2. Full variety of sensors  
The flowmeter can be used with various types of sensors  
applicable for wide range of pipe size (ø13 to ø6000mm)  
and fluid temperature (-40 to +200°C).  
3. High accuracy  
Detector  
(FSD)  
The flowmeter is designed for high accuracy (± 1.0%).  
The adoption of new sound velocity measurement  
system permits measurements of fluids of unknown  
sound velocity, and also slightly affection from fluid  
temperature and pressure.  
4. Excellent resistance against aerated flow  
Fuji's unique ABM feature improves measurement reli-  
ability for different flow like slurries, sludge, raw sewage  
and bubble-contained flow (acceptable up to air bubble  
of 12% volume at 1m/s velocity).  
Detector  
(FSG)  
5. Quick response  
With the use of high-speed micro-processor suited for digi-  
tal signal processing, the fast response time is realized.  
6. Multi-lingual  
The following languages are supported for display:  
Japanese (Katakana), English, German French, and  
Spanish.  
7. Excellent performance and easy operation  
LCD and function keys are allowing easy configuration  
and trouble shooting.  
Applicable fluid:Homogenous liquid where the ultrasonic  
signal can be transmitted  
Bubble quantity: 0 to 12vol% (for pipe size  
50A, water, velocity 1m/s)  
Fluid turbidity: 10000mg/L max.  
Type of flow: Fully-developed turbulent or  
laminar flow in a full-filled pipe  
Applicable flow pipe:  
Material:  
Plastics (PVC, FRP, etc.) or  
Metals (carbon steel, SS, cop-  
per, aluminum, etc.)  
− LCD with back light  
− Easy mounting of sensor  
− Trouble shooting  
Pipe size:  
50 to 6000 mm  
(inside diameter)  
Liner:  
Tar epoxy, mortar, etc.  
Straight pipe length: Typically 10D for upstream  
and 5D for downstream. Refer  
SPECIFICATIONS  
Operational specifications  
to JEMIS-032 in detail.  
System configuration:  
Velocity:  
Power supply:  
0 to ±0.3 ········±32 m/s  
The system is composed of two detectors  
(Model: FSG, FSD) and one Flow transmitter  
(Model: FSH), realizing two-path measure-  
ment.  
100 to 240 Vac+10%/-15%, 50/60Hz or 20 to  
30 Vdc  
EDS6-141d  
Date  
Apr. 1, 2011  
FSH, FSG, FSD  
Signal cable: High-frequency coaxial cable and 3-wire  
shielded cable.  
Display device:  
Graphic LCD (number of pixels: 240x64) with  
back light  
Display language:  
Japanese, English, French, German or Span-  
ish selectable  
Velocity/Flow rate display:  
Maximum cable length: 150m  
Allowable temperature limit: 80ºC  
Coaxial cable (4 pcs)  
Environment: Non-explosive environment without direct  
sunlight, corrosive gas and heat radiation  
Ambient temperature:  
-10 to +50ºC for flow transmitter,  
-20 to +80ºC for detector  
Ambient humidity:  
Display of velocity and/or flow rate with flow  
direction  
Data: up to 10 digits (decimal point to be  
counted as 1 digit)  
95%RH or less for flow transmitter, 100%RH  
or less for detector  
Grounding: Class D (less than 100 ohm)  
Unit: Metric/English system selectable  
Metric system  
English system  
ft/s  
Velocity  
m/s  
Arrester:  
Surge absorbers for outputs and power sup-  
ply incorporated as standard  
Flow rate  
L/s, L/min, L/h, L/d, kL/h,  
ML/d, m3/s, m3/min, m3/h,  
m3/d, km3/d, Mm3/d,  
BBL/s, BBL/min, BBL/h,  
kBBL/d, MBBL/d  
ft3/s, ft3/min, ft3/h, Mft3/d,  
gal/s, gal/min, gal/h, Mgal/d,  
BBL/s, BBL/min, BBL/h,  
BBL/d, kBBL/d, MBBL/d  
Performance specifications  
Accuracy :  
Note: ˝gal˝ means US gal.  
Detector  
Pipe size  
Applicable pipe  
material  
Flow velocity Accuracy  
(diameter)  
Total display: Display of forward or reverse total  
Data: up to 10 digits (decimal point to be  
counted as 1 digit)  
2 to 32m/s  
0 to 2m/s  
±1.0% of rate  
±0.02m/s  
ø50 to below ø300  
FSGS32  
FSD32  
FSGS51  
0.75 to 32m/s ±1.0% of rate  
0 to 0.75m/s ±0.0075m/s  
ø300 to ø6000 mm  
ø50 to below ø300  
ø300 to ø6000 mm  
Unit: Metric/English system selectable  
Plastic, metal pipe  
2 to 32m/s  
0 to 2m/s  
±1.5% of rate  
±0.03m/s  
Metric system  
English system  
FSGS31  
FSGS50  
ft3, kft3, Mft3, gal, kgal,  
mL, L, m3, km3, Mm3,  
Total  
0.75 to 32m/s ±1.5% of rate  
0 to 0.75m/s ±0.0113m/s  
mBBL, BBL, kBBL, ACRf  
mBBL, BBL, kBBL  
Configuration:  
Response time:  
Transit time method:  
Power consumption:  
Fully configurable on keyboard by menu-  
driven software  
0.5sec  
Zero adjustment:  
Set zero/Clear available.  
20W or less  
Damping:  
0 to 100s (every 0.1s) configurable for analog  
output and display  
Functional specifications  
Analog output: 4 to 20 mAdc (1 point)  
Max. load resistance: 1k ohm  
Digital output: +total, -total, alarm, acting range, flow  
switch or total switch -- arbitrarily selectable  
Mechanical relay contact:  
Low flow cut off:  
0 to 5 m/s configurable  
Alarm:  
Hardware fault/process fault can be tied to  
digital output  
Analog output: Hold/Upper limit/Lower limit/  
Zero/Not-used selectable  
Total: Hold/Count selectable  
Timer: 0 to 900s (every 1s) configurable  
Burnout:  
1 point with socket (replaceable)  
Normally closed/open selectable  
Capacity:240 Vac/30 Vdc, 1 A  
Bi-directional range:  
Forward and reverse ranges configurable in-  
Total pulse: less than 1 p/s  
(Pulse width: 50, 100 or 200 ms  
selectable)  
Transistor open collector: 2 points  
Capacity: 30 Vdc, 0.1 A  
dependently  
Hysteresis: 0 to 20% of working range con-  
figurable  
Working range applicable to digital output  
Normally off/on selectable  
Auto-2 ranges:  
Total pulse: less than 1000 p/s  
(Pulse width: 0.5, 1, 2, 5, 10, 20,  
50, 100 or 200 ms selectable)  
Forward 2 ranges configurable independently  
Hysteresis: 0 to 20% of working range con-  
figurable  
Communication interface:  
Working range applicable to digital output  
RS-232C equivalent / RS-485 (selectable)  
Number of connectable units: one (RS-232C)/  
up to 31 (RS-485)  
Baud rate: 9600/19200/38400 bps selectable  
Parity: none/odd/even selectable  
Stop bit: 1 or 2 bits selectable  
Distance: up to 15 m (RS-232C)/up to 1k m  
(RS-485)  
Flow switch: Lower and upper switching points configu-  
rable independently  
Acting point applicable to digital output  
Total switch: +total switching point configurable  
Acting point applicable to digital output  
Data: velocity, flow rate, +total, -total, status  
(standard), velocity profile (option)  
2
Signal cable:  
FLY8, FLY9 (applicable detector: FSG,  
FSD)  
•Structure: High frequency coaxial cable  
(double shield)  
•Sheath: Black flame-resisting PVC  
•Outer diameter: ø7.5mm  
•Termination: M3.5 amp terminal (flow  
transmitter side) and M4 amp terminal  
(FLY8).Note, however, that the detecter  
side of FSD32 is provided with BNC  
connector (FLY9).  
•Mass: Approx. 90g/m  
Flow transmitter FSH:  
H240×W247×D134mm  
Detector: H46×W410×D50mm (FSGS3)  
H67×W78×D84mm (FSGS5)  
Physical specifications  
Enclosure protection:  
Flow Transmitter: IP67,  
Detector:  
FSG (common type):  
IP67 (Silicon compound is filled on the  
terminal part when wiring)  
FSG (submersible type):  
IP68 (submersible in water for 5 days)  
FSD (high temperature type): IP52  
Flow Transmitter: wall mount  
Detector: clamped on pipe surface  
Mounting:  
Dimensions:  
Acoustic coupler: Silicon compound (RTV)  
Material:  
Flow Transmitter: aluminum alloy  
Detector:  
Detector Sensor housing Sensor cover Guide rail  
H205×W530×D52mm (FSD32)  
FSGS3  
FSGS5  
FSD32  
PBT  
SUS304  
SUS304  
SUS304 + plastic  
PBT  
Mass:  
Flow transmitter : 5kg  
Detector: 0.6kg (FSGS3)  
1.2kg (FSGS5)  
SUS304  
SUS304 + aluminum alloy  
1.6kg (FSD32)  
Conditions on straight pipe  
( D : Inside diameter of pipe)  
Classification  
Upstream side  
Downstream side  
5D  
L
L
10D  
90 bend  
Detector  
L
L
10D  
50D  
Tee  
10D or more  
L
5D  
L
30D  
Diffuser  
1.5D  
L
5D  
L
10D  
Reducer  
L
30D  
L
10D  
Various Valve  
In case that flow control valve exists on  
upstream side.  
In case that flow control valve exists on  
downstream side.  
Stop valve  
Check valve  
L
50D  
Pump  
P
(Note) The source : JEMIS-032  
3
FSH, FSG, FSD  
MEASUREMENT PRINCIPLE  
MOUNTING OF DETECTOR  
Ultrasonic pulses are propagated aslant between the up-  
stream and downstream sensors, detecting the time differ-  
ence due to flow for measurement.  
Plastic wedge  
Pipe  
Ultrasonic oscillator  
Upstream sensor  
Lining  
Output signal  
Flow  
transmitter  
D
t2  
t1  
Velocity V  
Downstream sensor  
CONFIGURATION DIAGRAM  
(1) 2-path system (V method)  
Cable  
(2) 2-path system (Z method)  
Cable  
Flow  
transmitter  
Flow  
Detector  
Detector  
transmitter  
4-20mA DC  
4-20mA DC  
Contact (up to 3 points)  
Contact (up to 3 points)  
DETECTOR SELECTION GUIDE  
Inner diameter of piping ø (mm)  
Type  
Fluid  
Mounting  
13 25  
50  
100  
200  
250  
300  
400  
1000  
3000  
6000  
temperature [°C] method  
FSGS32 Note)  
FSGS31  
300  
V
50  
Px, P, M  
–40 to 80  
V
200  
200  
3000  
Px, P, M  
FSGS51 Note)  
FSGS50  
6000  
Z
Px, P, M  
50  
250  
Px, P, M  
V
FSD32  
–40 to 200  
Z
150  
Px, P, M  
400  
Px : PP, PVDF  
: Plastic (PVC, etc.)  
M : Msetallic piping (steel pipe, copper pipe, aluminum, etc.)  
Classification of  
piping materials  
P
Note: The ultrasonic signal cannot be transmitted easily when the classification of piping material is Px or the turbidity is high.  
In such a case, a preliminary check by a portable ultrasonic flowmeter is recommended.  
4
<Detector, submersible type>  
CODE SYMBOLS  
1
2
3
4
5
6
7
8
9
10 11 12 13  
Description  
F S G S  
A 1  
1
<Flow transmitter>  
Type (5th and 6th digits)  
1
2
3
4
5
6
7
8
9 10 11 12  
3 2  
3 1  
5 1  
5 0  
Small sensor 2MHz (ø50 to ø300)  
Small sensor 1MHz (ø50 to ø300)*2  
Large sensor 1MHz (ø200 to ø6000)  
Large sensor 0.5KHz (ø200 to ø6000)*2  
V method  
F S H Y A  
1
S Y Y  
Description  
Type (4th digit)  
V or Z  
method  
E
Standard  
Use (6th digit)  
Dedicated signal cable (9th digit)  
Transit time measurement (two path)  
B
C
D
E
10m  
20m  
30m  
40m  
50m  
60m  
70m  
80m  
A
Power supply (7th digit)  
100 to 240 Vac, 50/60 Hz  
20 to 30 Vdc  
1
4
F
Conduit connection (10th digit)  
G1/2 and G3/8 (female screw) with  
water-proof connection  
G
H
J
Y
K
L
M
N
P
Q
R
Z
90m  
Parameter setting, Tag Plate (12th digit)  
None  
With setting  
With setting and Tag Plate  
With Tag Plate  
100m  
110m  
120m  
130m  
140m  
150m  
Specified length  
Y
A
B
C
(Contact us if length is more than 150m.  
Max. length is 300m.)  
<Detector, high temperature type>  
Acoustic coupler (10th digit)  
1
2
3
4
5
6
7
8
A
C
Silicon rubber (KE348)  
5
F S D  
1
Description  
Silicone grease (G40M)  
*
Additional specification (11th digit)  
None  
Tag plate  
Type (4th, 5th and 6th digits)  
High-temperature sensor *1  
(ø50 to ø400), V or Z method  
Y
A
3 2 0  
Wire rope for mounting (12th digit)  
Specify it in the case of FSGS41 or FSGS5.  
None  
Nominal diameter: up to ø500mm  
Nominal diameter: up to ø1000mm  
Nominal diameter: up to ø1500mm  
Belt, acoustic coupler (7th digit) *3  
For fixed type  
Y
Y
A
B
C
D
E
<
1
>
Detector, common type  
Nominal diameter: up to ø3000mm  
Nominal diameter: up to ø6000mm  
Can be specified  
only for FSGS5  
2
3
4
5
6
7
8
9
10 11 12 13  
Description  
F S G S  
Y 1  
Y
1
Type (5th and 6th digits)  
3 2  
3 1  
5 1  
5 0  
Small sensor 2MHz (ø50 to ø300)  
Small sensor 1MHz (ø50 to ø300)*2  
Large sensor 1MHz (ø200 to ø6000)  
Large sensor 0.5KHz (ø200 to ø6000)*2  
V method  
*1: For turbid fluid or old pipe, cast iron pipe, mortar lining pipe  
or others through which the ultrasonic signal could not be  
transmitted easily, use an optional guide rail (TK4C6164C1),  
and carry out mounting by Z method.  
V or Z  
method  
Acoustic coupler (10th digit)  
4
Applicable diameter range  
V method: ø50 to ø250 Z method: ø150 to ø400  
Y
A
B
C
None  
*
Silicon rubber (KE348W)  
Silicone-free grease (HIGH-Z)  
5
*
*2: For aging pipes, cast iron pipes or mortar-lined pipes that  
interrupts the propagation of ultrasonic signals, select  
FSGS31 or FSGS50.  
5
Silicone grease (G40M)  
*
Additional specification (11th digit)  
None  
Tag plate  
Y
A
*3: As for the acoustic coupler, grease (KS62M) for high  
temperatures is attached.  
Wire rope for mounting (12th digit)  
Specify it in the case of FSGS41 or FSGS5.  
None  
*4: Silicone rubber (KE-348W) is provided as a standard  
accessory to fill the wiring mold. (It can also be used as an  
acoustic coupler.)  
Y
A
B
C
D
E
Nominal diameter: up to ø500mm  
Nominal diameter: up to ø1000mm  
Nominal diameter: up to ø1500mm  
Nominal diameter: up to ø3000mm  
Nominal diameter: up to ø6000mm  
If an additional acoustic coupler is required, select one  
among A, B and C.  
Can be specified  
only for FSGS5  
*5: Normally select silicone rubber as acoustic coupler.  
Siliconerubber in tube (100g) is furnished. If you place an  
order for several units, 1 tube may suffice for every 2 units.  
Select silicone-free grease for semiconductor anufacturing  
equipment or the like that is vulnerable to silicone.  
The silicone-free grease is water-soluble and, therefore,  
cannot be used in environment exposed to water or on  
piping subjected to a condensation. Since the grease does  
not set, a periodic maintenance (cleaning, refilling every  
about 6 months at normal temperature) is necessary.  
5
FSH, FSG, FSD  
<Signal cable>  
Note: Must be procured unless the sensor is a submersible type.  
• For detector FSG and FSD  
1
2
3
4
5
6
7
8
F L Y  
1
Description  
Type of sensor (4th digit)  
8
9
Small and large sensor (for FSG)  
Hight temp sensor (for FSD)  
Cable length (5,6 and 7th digit)  
0 0 5  
0 1 0  
0 1 5  
0 2 0  
0 2 5  
0 3 0  
0 3 5  
0 4 0  
0 4 5  
0 5 0  
0 5 5  
0 6 0  
0 6 5  
0 7 0  
0 7 5  
0 8 0  
0 8 5  
0 9 0  
0 9 5  
1 0 0  
1 1 0  
1 2 0  
1 3 0  
1 4 0  
1 5 0  
Z Z Z  
5 m  
10 m  
15 m  
20 m  
25 m  
30 m  
35 m  
40 m  
45 m  
50 m  
55 m  
60 m  
65 m  
70 m  
75 m  
80 m  
85 m  
90 m  
95 m  
100 m  
110 m  
120 m  
130 m  
140 m  
150 m  
Others (contact us)  
Note: Preapare a detector and dedicated signal cable (2 set).  
Loader software for PCs  
Equipped as standard  
• Works on PC/AT compatible machines.  
• Operation on PC98-series machines (NEC) cannot be  
guaranteed.  
• Operation on self-made PCs or shop-brand PCs cannot  
be guaranteed.  
• Major functions: Setting/changing of various parameters  
for the main unit  
O/S: Windows2000/XP  
• Memory requirement: 128MB or more  
• Disk unit: Windows2000/XP-compatible CD-ROM drive  
• Hard disk drive capacity: Free space of 52MB or more  
Note: PC loader communication cable (type ZZP*TK4H6253,  
Specifications: D-sub 9 pin receptacle, cable length  
3m) is separately required.  
SCOPE OF DELIVERY  
ITEMS DESIGNATED ORDERING  
•Flow transmitter (Type: FSH): Flow transmitter  
CD-ROM (Instruction manual,  
1.Detector code symbols  
2.Flow transmitter code symbols  
3.Signal cable code symbols  
Loader software)  
•Detector (Type: FSG, FSD): Sensor unit, Mounting belt,  
Silicon compound  
4.For large sensor: Mounting pipe size  
5.Tag No. as necessary  
•Signal cable (Type: FLY): Cable (2 wires)  
6.If parameter setting is specified, send back the attached  
parameter specification table duly filled.  
6
(Unit:mm)  
OUTLINE DIAGRAM  
<Flow transmitter (type: FSH)>  
Mtg. plate  
Duosonics  
72  
3
134  
14  
233  
5-G3/8  
Female screw  
4-G1/2  
Female screw  
30 30 30  
48 48  
24  
48  
CONNECTION DIAGRAM  
Power supply terminals (AC)  
1
L
2
N
3
4
1
2
3
4
5
6
7
8
9
B
B
A
+
100 to 240V AC  
50/60Hz  
SERIAL  
Iout  
SERIAL  
No.  
Power supply terminals (DC)  
Communication cable  
(option)  
RS485  
TRX2 (  
RS232C  
1
+
2
3
4
4
5
6
)
TXD  
RXD  
COM  
Cap (red)  
Cap (yellow)  
Cap (black)  
TRX1 (+)  
20 to 30V DC  
SHILD  
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
HF GND HF GND HF GND HF GND  
+
+
+
UP STR DOWN STR UP STR DOWN STR  
DO1  
DO2  
DO3  
Relay contact  
LINE1  
LINE2  
Open collector  
7
FSH, FSG, FSD  
Saddle  
Connector  
Scale(mm)  
(Unit:mm)  
OUTLINE DIAGRAM  
Scale(inch)  
Name plate  
Lock nut  
Element holder  
Cursor  
φ26  
33±0.5  
90max.  
205max.  
44±±  
Detector FSD32 (High-temperature sensor)  
Frame  
Sensor  
Frame  
410±2  
400  
Sensor  
410±2  
400  
5
5
5
5
P
P
Name plate  
47  
Spacing : 0 to 270mm  
Name plate  
47  
Spacing : 0 to 270mm  
50±1  
33  
Chain  
50±1  
33  
Chain  
Mounting spring  
Mounting spring  
Frame guide  
VIEW FROM P  
Frame guide  
VIEW FROM P  
(Common type)  
(Submersible type)  
Detector FSGS3 (Small sensor)  
Name plate  
Name plate  
114  
114  
78±1  
Sensor  
Wire rope  
Mounting spring  
78±1  
L(cable length (m) : specified by order)  
Wire rope  
Sensor  
Mounting spring  
(Common type)  
(Submersible type)  
Detector FSGS5 (Large sensor)  
8
Signal cable : FLY8 (For FSG)  
8
To Detector  
ø11  
ø7.3  
To Flow transmitter  
L : By specification  
when ordered.  
5.5  
Signal cable : FLY9 (For FSD)  
Loader cable : ZZP*TK4H6253  
34  
Connector  
ø14.5  
BNC connector  
ø11  
To Personal  
computer  
ø7.3  
To Detector  
ø6.9  
To Flow transmitter  
Terminal cap (Yellow)  
Terminal cap (Black)  
To Flow transmitter  
Terminal cap  
(Red)  
L : By specification  
when ordered.  
Black  
COM  
Red  
Yellow  
RXD  
3-ø3.7  
TXD  
6.6  
5.5  
RS-232C  
9
FSH, FSG, FSD  
<Parameter specification table>  
No.  
1
Setting item  
Settable range  
Initial value  
60.00mm  
Settable value  
Outer diameter  
10.00 to 6200.00mm  
[mm, inch]  
(0.393 to 244.100 inch)  
(2.362 inch)  
2
Pipe material  
12 menus  
PVC  
Carbon steel, Stainless steel, PVC, Copper,  
Castiron, Aluminum, FRP, Ductileiron, PEEK,  
PVDF, Acrylic  
Pipe S.V. : 1000 to 3700m/s  
(3280 to 12140 ft/s)  
Others (Sound velocity :  
[m/s, ft/s])  
3
4
Wall thickness  
Lining material  
0.10 to 100.00mm  
(0.003 to 3.940 inch)  
4.00mm  
(0.157 inch)  
[mm, inch]  
8 menus  
No lining  
No lining, Tar epoxy, Mortar, Rubber,  
Teflon, Pyrex glass, PVC,  
Lining S.V. : 1000 to 3700m/s  
(3280 to 12140 ft/s)  
Others (Sound velocity :  
[m/s, ft/s])  
5
6
Lining thickness  
Kind of Fluid  
0.01 to 100.00mm  
(0.000 to 3.940 inch)  
[mm, inch]  
17 menus  
Water  
Water, Seawater, DIST. water, Ammonia,  
Alcohol, Benzene, Bromide, Ethanol, Glycol,  
Kerosene, Milk, Methanol, Toluol,  
Lube oil,  
Fluid S.V. : 500 to 2500m/s  
(1641 to 8203 ft/s)  
Fuel oil, Petrol,  
Others (Sound velocity :  
(Kinematic viscosity  
[m/s, ft/s])  
Kinematic viscosity :  
[x10-6m2/s, ft2/s])  
0.001 to 999.9999 x 10-6m2/s  
(0.0107 to 10763.9088 x 10-6ft2/s)  
19 menus  
m/s  
(ft/s)  
m/s, L/s, L/min, L/h, L/d, kL/d, ML/d, m3/s,  
m3/min, m3/h, m3/d, km3/d, Mm3/d, BBL/s,  
BBL/min, BBL/h, BBL/d, KBBL/d, MBBL/d,  
(ft/s, ft3/s, ft3/min, ft3/h, ft3/d, kft3/d, Mft3/d,  
gal/s, gal/min, gal/h, gal/d, kgal/d, Mgal/d,  
BBL/s, BBL/min, BBL/h, BBL/d, kBBL/d,  
MBBL/d)  
7
Range unit  
8
9
Range type  
4 menus  
Single  
Single, Auto 2, Bi-dir, Bi-dir Auto 2  
[
Full scale or  
Full scale 1  
In terms of flow velocity 0.00 ···  
0.30 to 32.00m/s  
2.00m/s  
(6.56 ft/s)  
]
]
(0.98 to 104.98 ft/s)  
10  
Full scale 2  
In terms of flow velocity 0.00 ···  
0.30 to 32.00m/s  
4.00m/s  
(13.12 ft/s)  
[
(0.98 to 104.98 ft/s)  
11  
12  
13  
14  
15  
16  
Range HYS.  
0.00 to 20.0%  
-20 to 0%  
10.00%  
-20%  
%
%
%
Output limit LO.  
Output limit HI.  
Output burnout  
Burnout timer  
Rate limit  
100 to 120%  
5 menus  
120%  
Hold  
Not use, Hold, Upper, Lower, Zero  
0 to 900sec  
10sec  
sec  
]
0.00 to 5.00m/s  
0.00m/s  
[
(0.00 to 16.40 ft/s)  
in terms of flow velocity  
(0.00 ft/s)  
17  
Rate limit timer  
0 to 900sec  
0.0 to 100.0sec  
7 menus  
0sec  
sec  
sec  
18 Damping  
5.0sec  
19  
20  
1 : Display kind  
Flowrate (m3/s)  
Flow velocity, Flowrate, Total forward,  
Total reverse,  
F : Total pulse, R : Total pulse, Flow rate (%)  
2 : Display kind  
7 menus  
Flow velocity (m/s) Flow velocity, Flowrate, Total forward,  
Total reverse,  
F : Total pulse, R : Total pulse, Flow rate (%)  
21 Low flow cut  
0.00 to 5.00m/s  
0.01m/s  
[
]
(0.00 to 16.40 ft/s)  
in terms of flow velocity  
(0.03 ft/s)  
10  
No.  
22  
Setting item  
Total mode  
Settable range  
Initial value  
Total stop  
Settable value  
3 menus  
8 menus  
Total stop, Total run, Total reset  
23  
Total unit  
mL  
mL, L, m3, km3, Mm3, mBBL, BBL, kBBL,  
ft3, kft3, Mft3, kgal, gal, mBBL, BBL, kBBL,  
ACRF  
24  
25  
26  
27  
28  
29  
30  
31  
32  
Total rate  
0.000 to 999999.999  
0.000 to 9999999999.999  
0.000 to 9999999999.999  
0.000 to 9999999999.999  
0.000 to 9999999999.999  
2 menus  
0.000  
0.000  
0.000  
0.000  
0.000  
Hold  
[
]
]
]
]
]
[
F : Total preset  
F : Total SW  
R : Total preset  
R : Total SW  
Output burnout  
Burnout timer  
Pulse width 1  
Pulse width 2  
[
[
[
Not use, Hold  
0 to 900sec  
10sec  
50ms  
50ms  
sec  
3 menus  
50, 100, 200  
9 menus  
0.5, 1.0, 2.0, 5.0, 10.0, 20.0, 50.0, 100.0,  
200.0  
33  
34  
Flow sw high  
Flow sw low  
In terms of flow velocity  
0.00 to 32.00m/s  
(0.00 to 104.98 ft/s)  
0.00m/s  
4.00m/s  
[
]
]
In terms of flow velocity  
0.00 to 32.00m/s  
[
(0.00 to 104.98 ft/s)  
35  
36  
Flow sw HYS.  
Output DO1  
0 to 20%  
15 menus  
10%  
%
Not use  
Not use, Signal error, F : Total pulse,  
R : Total pulse, F : Total alarm,  
R : Total alarm, F : Total overflow,  
R : Total overflow, Flow SW high,  
Flow SW Low, Full scale2, AO range over,  
Pulse range over, R : Flow direction,  
Device error  
37  
38  
Mode DO1  
2 menus  
Normal  
Not use  
Normal, Reverse  
Output DO2  
15 menus  
Not use, Signal error, F : Total pulse,  
R : Total pulse, F : Total alarm,  
R : Total alarm, F : Total overflow,  
R : Total overflow, Flow SW high,  
Flow SW Low, Full scale2, AO range over,  
Pulse range over, R : Flow direction,  
Device error  
39  
40  
Mode DO2  
2 menus  
Normal  
Not use  
Normal, Reverse  
Output DO3  
15 menus  
Not use, Signal error, F : Total pulse,  
R : Total pulse, F : Total alarm,  
R : Total alarm, F : Total overflow,  
R : Total overflow, Flow SW high,  
Flow SW Low, Full scale2, AO range over,  
Pulse range over, R : Flow direction,  
Device error  
41  
Mode DO3  
2 menus  
Normal  
Normal, Reverse  
11  
FSH, FSG, FSD  
No.  
42  
Setting item  
Settable range  
Initial value  
Metric  
Settable value  
System unit  
Language  
2 menus  
5 menus  
Metric, English  
43  
English  
Japanese, English, German, French,  
spanish  
44  
45  
46  
47  
48  
49  
COM. speed  
3 menus  
3 menus  
2 menus  
2 menus  
38400BPS  
None  
1 bit  
9600BPS, 19200BPS, 38400BPS  
None, Even, Odd  
1 bit, 2bits  
COM. parity  
COM. stop bit  
Serial method  
Station No.  
RS232C  
1
RS232C, RS485  
1 to 31  
31 menus  
2 menus  
Measurement  
mode  
1 Path  
(2 path)  
2 Path  
Note2  
50  
51  
AO Definition  
3 menus  
4 menus  
Line 1  
(Average) Note2  
Average, Line 1, Line 2  
FSW12, FSW21, FSW40, FSW50,  
FSW12  
Sensor Type  
FLW11/FSG31, FLW41/FSG41, FLW12/FSG32,  
FLD12/FSD12, FLD22/FSD22, FLW32/FSD32,  
FLS50/FSG50, FLW51/FSG51  
(FLW51/FSG51)  
Note2  
Note1: When total pulse output has been selected for DO1, DO2 or DO3 specify total pulse value and total pulse width so that conditions 1  
and 2 shown below are satisfies.  
Flow span-1*[m3/s]  
total pulse value*[m3]  
Condition 1 :  
Condition 2 :  
1000 [In the case of DO1 and DO2]  
1 [In the case of DO3]  
Flow span-1*[m3/s]  
total pulse value*[m3]  
1000  
2 × total pulse width [ms]  
* In the case of 2 ranges, perform calculations using either flow span-1 or flow span-2, whichever is greater.  
Note2: Settable value at the time of shipment.  
Caution on Safety  
*Before using this product, be sure to read its instruction manual in advance.  
International Sales Div  
Sales Group  
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,  
Shinagawa-ku, Tokyo 141-0032, Japan  
http://www.fujielectric.com  
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425  
http://www.fjielectric.com/products/instruments/  
Information in this catalog is subject to change without notice.  
Printed in Japan  

相关型号:

EDS6-33B

FCX SERIES DIFFERENTIAL PRESSURE TRANSMITTER
FUJI

EDS6-34F

FCX SERIES REMOTE SEAL TYPE DIFFERENTIAL PRESSURE TRANSMITTER
FUJI

EDS6-35D

FCX SERIES FLOW TRANSMITTER
FUJI

EDS6-50I

DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATE WITH CARRIER RINGS
FUJI

EDS6-51E

DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATES WITHOUT CARRIER RINGS
FUJI

EDS6-52G

DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATES WITH FLANGE TAPPINGS
FUJI

EDS6-54E

SINGLE-PART DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATE
FUJI

EDS6-58F

PORTABLE TYPE ULTRASONIC FLOWMETER(PORTAFLOW)
FUJI

EDS6-61H

COMPACT ELECTROMAGNETIC FLOWMETER(COMPACT FLOW)
FUJI

EDS6-64A

COMPACT ELECTROMAGNETIC FLOWMETER(COMPACT FLOW)
FUJI

EDS6-65

COMPACT ELECTROMAGNETIC FLOWMETER(COMPACT FLOW, SEPARATE TYPE)
FUJI

EDS6-69B

INTEGRAL TYPE ELECTROMAGNETIC FLOWMETER
FUJI