EDSX5-74 [FUJI]
FCX â AX SERIES SMALL FLANGE REMOTE SEAL TYPE PRESSURE TRANSMITTER; FCX â ???? AX系列小法兰远传密封压力变送器![EDSX5-74](http://pdffile.icpdf.com/pdf2/p00206/img/icpdf/EDSX5-_1167576_icpdf.jpg)
型号: | EDSX5-74 |
厂家: | ![]() |
描述: | FCX â AX SERIES SMALL FLANGE REMOTE SEAL TYPE PRESSURE TRANSMITTER |
文件: | 总10页 (文件大小:204K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
FCX – AX SERIES
SMALL FLANGE REMOTE SEAL TYPE
PRESSURE TRANSMITTER
...
DATA SHEET
FHW, FKW 3
The FCX –AX Series small flange remote seal type pres-
sure transmitter accurately measures gauge pressure and
transmits a proportional 4 to 20mA signal.
The transmitter utilizes a unique micromachined capaci-
tance silicon sensor with state-of -the-art microprocessor
technology to provide exceptional performance and func-
tionality.
Totally welded construction of the seals assures excellent
reliability in high temperature and highly corrosive process
conditions.
7. Burnout current flexibility (Under Scale: 3.2 to 3.8mA,
Over Scale: 20.8 to 21.6mA)
Burnout signal level is adjustable using Model FXW hand
Held Communicator (HHC) to comply with NAMUR NE43.
(Available for amplifier unit from version 24 and FXW(HHC) version
5.3.)
FEATURES
1. Directly connectable to 1-1/2in and 2in flanges
The transmitter is connectable to 1-1/2in and 2in pipes
without a reducer.
2. Connectable to 1/2in and 3/4in pipes
Use of direct mounting adapter allows the transmitter to
be connected to the following process.
1/2in and 3/4in flanges
Screw connection 1/2-14NPT, 3/4-14NPT, Rc1/2, Rc3/4
3. Minimum environmental influence
8. Dry calibration without reference pressure
Thanks to the best combination of unique construction
of mechanical parts (Sensor unit) and high performance
electronics circuit (Electronics unit), reliability of dry
calibration without reference pressure is at equal level
as wet calibration.
The "Floating Cell" design which protects the pressure
sensor against changes in temperature, and overpressure
substantially reduces total measurement error in actual
field applications.
4. Replaceable Communication Module
Fuji micro-electronics manufacturing technology offers
replaceable communication module that makes FCX–AX
transmitter very unique in design. In case of change in
communication protocl, all that needs to be done is just to
replace the module and the transmitter gets upgraded to
the new version.
5. Fuji/HART bilingual communication module
The communication module is "bilingual" to speak both Fuji
proprietary protocol and HART. Any HART compatible
devices can communicate with FCX–AX series transmit-
ters.
SPECIFICATIONS
Functional specifications
Type:
Model FHW: 4 to 20mA
Model FKW: 4 to 20mA with digital signal
Service:
Liquid, gas, or vapour
Span, range, and overrange limit:
Span limit [kPa]{bar}
Overrange
limit
[MPa] {bar}
Range limit
[kPa]{bar}
Type
Min.
Max.
FHW/FKW
FHW
300
{3}
1000
{10}
FKW
50
{0.5}
250
F
F
W
3
4
3000
{30}
10000
{100}
–100 to +3000
{–1 to +30}
–100 to 10000
{–1 to 100}
4.5
{45}
15
6. Application flexibility
Various options that render the FCX–AX suitable for
almost any process applications include:
W
{2.5}
{150}
—
—
Lower range limit (vacuum limit) ;
Silicone fill sensor: See Fig. 1
Fluorinated fill sensor: Atmospheric pressure
Conversion factors to different units;
1MPa=103kPa=10bar=10.19716kgf/cm2=145.0377psi
1kPa=10mbar=101.9716mmH2O=4.01463inH2O
—
Analog indicator at either the electronics side or ter-
minal side
—
—
—
—
—
—
Full range of hazardous area approvals
Built-in RFI filter and lightning arrester
1
/
2
4
-digits LCD meter
Stainless steel electronics housing
Wide selection of materials
High temperature, vacuum seals
Output signal:
Model FHW: 4 to 20mA DC 2-wire
Model FKW: 4 to 20mA DC with digital signal super-
imposed on the 4 to 20mA signal.
Power supply:
Transmitter operates on 10.5V to 45V DC
at transmitter terminals.
10.5V to 32V DC for the units with op-
tional arrester.
EDSX5-74
Date
Apr. 10, 1999
...
FHW, FKW 3
Load limitations: see figure below
[Ω]
“Output Underscale”:
Approx. 3.8mA
(Adjustable within the range 3.2mA to
3.8mA from HHC)
2000
1533Ω
4
3.8
20 20.8
3.2
1500
Over scale
Burnout
0
1000
21.6
Normal operating range
Probable under range
600Ω
Under scale
Burnout
Probable over range
Operating
area
500
250
24V
45V
50
Loop-check output:
Model FHW: Transmitter can output constant signal of
4mA, 12mA, or 20mA if MODE SWITCH
is set to the loop check mode.
10 16.1
10.5V
[ V ]
Power voltage
Model FKW: Transmitter can be configured to provide
constant signal 3.8mA through 21.6mA by
HHC.
Note: For communication with HHC (Model: FXW), min. of 250Ω is required.
Hazardous locations: (Approval pending)
Temperature limit:
Ambient: –15 to +65°C
Type N
Nonincendive
Authorities
Flameproof
Intrinsic safety
(– 15 to +60°C for arrester option)
(–10 to +60°C for fluorinated oil fill transmitter)
(–10 to +60°C for silicone oil "H", "S")
For explosionproof units (flameproof or intrinsic safety),
ambient temperature must be within the limits speci-
fied by each standard.
BASEEFA
Factory
Mutual
Ex ds IIC T5, T6
Class I II III
Div. 1
EEx ia IIC T4, T5
Class I II III
Div. 1
Ex N II T5
Class I II III
Div. 2
Groups B thru. G Groups A thru. F
Groups A thru. G
RIIS
Ex ds IIB+H2 T4
—
—
Zero/span adjustment:
Process:
Model FHW: Zero is adjustable from the external ad-
justment screw.
Lower limit
13th digit of
"Code symbols"
Process
temperature
of
Fill fluid
The adjustment screw can also function to
adjust span when MODE SWITCH (lo-
cated on the electronics unit) is in the span
mode. INHIBIT mode to disable the ad-
justment screw is also available.
static press.
Fluorinated oil W, A and D
–20 to 120°C Atmospheric
pressure
Silicone oil
H
0 to 250°C
Y and G
S
–40 to 120°C
0 to 250°C
2.7kPa abs
{20mmHg
abs}
Model FKW: Zero and span are adjustable from the
HHC. Zero is also adjustable externally
from the adjustment screw.
Storage: –40 to +70°C
Humidity limit: 0 to 100% RH
Communication: (Model FKW only)
Damping:
Adjustable electrical damping.
Model FHW: The time constant is adjustable to 0, 0.3,
1.2, 4.8, or 19.2 seconds.
With HHC (Model FXW, consult Data
Sheet No. EDS8-47), following informa-
tion can be remotely displayed or recon-
figured.
Model FKW: The time constant is adjustable between 0
to 38.4 seconds.
Zero elevation/suppression:
Zero can be elevated or suppressed within
the specified range limit of each sensor
model.
Items
Display
Set
v
v
v
Tag No.
v
Model No.
Normal/reverse action:
v
—
v
Serial No.
Selectable by moving a jumper pin located
Engineering unit
Range limit
v
on the electronics unit.
/
v
—
v
Indication:
Analog indicator or 4 1 2-digit LCD meter,
as specified.
Measuring range
Damping
v
Burnout direction:If self-diagnostic detect transmitter fail-
ure, the analog signal will be driven to ei-
ther “Output Hold”, “Output Overscale”
or “Output Underscale” modes.
Model FHW: Unless otherwise specified in the order,
the transmitter will be shipped in “Output
Hold” mode.
v
v
v
v
Output mode
Burnout direction
Adjustment
Output adjust
Data
v
v
v
v
—
v
v
—
—
—
v
v
Self diagnoses
Printer
(Output signal just before failure happens
is maintained.)
Model FKW: Selectable from HHC
“Output Hold”:
—
v
External switch lock
Transmitter display(*)
v
v
Output signal is hold as the value just be-
fore failure happens.
“Output Overscale”:
Note: (*) HHC's version must be more than 5.0 (or
FXW 1– 2), to use this function.
Approx. 21.6mA
(Adjustable within the range 20.8mA to
21.6mA from HHC)
2
Performance specifications
Physical specifications
Accuracy rating: (including linearity, hysteresis, and re-
Electrical connections:
(Standard)
peatability)
G1/2, 1/2-14 NPT, Pg13.5, or M20 x 1.5
conduit, as specified.
Process connections:
For spans greater than 1/10 of URL: ±0.25% of span
For spans below 1/10 of URL (Model FKW only):
JIS;
0.1 x URL
Span
±
0.17+0.08
% of span
(
)
10K, 20K, 30K, 63K –40, 50A
10K, 20K, 30K, 63K –15, 20A (with
Adapter)
(Option)
For spans greater than 1/10 of URL: ±0.1% of span
For spans below 1/10 of URL (Model FKW only):
0.1 x URL
ANSI/JPI;
150LB, 300LB, 600LB, –1 1 2", 2"
/
±
0.05+0.05
% of span
(
)
Span
0.1% of calibrated span
150LB, 300LB, 600LB, –1/2", 3/4" (with
Adapter)
Screw connection (with Adapter) ;
Rc1/2, Rc3/4, 1/2-14NPT, 3/4-14NPT
Linearity:
Stability:
±0.2% of upper range limit (URL) for 24
months
Temperature effect:
Effect per 28°C change between the lim-
Diaphragm extension:
0, 50, 100, 150, or 200mm as specified.
(See model code. Extended diaphragm is
available only with 316L stainless steel dia-
phragm)
its of –15°C and +65°C
Zero shift: ±0.5%/28°C
(x equal to 1/6.5 URL or more)
URL
Process-wetted parts material:
Zero shift; ± (0.5
)%/28°C
6.5 x x
(x less than 1/6.5 URL)
Diaphragm: 316L stainless steel, Hastelloy-C
Monel or Tantalum
Flange face: 316 stainless steel, Hastelloy-C
lining
Total shift; ±0.75%/28°C
(x less than 1/6.5 URL or more)
URL
Monel lining or Tantalum lin-
ing
Total shift; ±(0.25 + 0.5
)%/28°C
6.5 x x
(x less than 1/6.5 URL)
Extension: 316 stainless steel
(Refer to "Code symbols")
Non-wetted parts material:
Where, x:
Calibrated span
URL: Maximum span (Upper Range
Limit)
Note 1: Condition:
Electronics housing: Low copper die-cast
aluminum alloy (standard), finished
with polyester coating, or 316 stainless
steel (SCSI4 per JIS G5121), as speci-
fied.
Capillary: In case of 13th code "Y. W. G. A.
D", PVC armored stainless steel.
In case of 13th code "H. S",
stainless steel armored stainless steel.
Mounting flange: (option) 304 stainless
steel or carbon steel
Fill fluid: Silicone oil (standard) or fluori-
nated oil (Daifloil)
Mounting bracket: Carbon steel with ep-
oxy coating or 304 stainless steel, as
specified
Capillary length: 3m max.
In case the capillary length is 5m, the per-
formance becomes 1.5 times worse than
above.
Note 2: In case the 7th code (material code) is
other than W, A, B, C or D, the perfor-
mance becomes 2.5 times worse than
above.
Note 3: Above specifications are based on the con-
ditions that flange and sensor unit are at
the same temperature and in the same
level. If temperature is different at flange,
capillary or sensor unit, output variation
may increase.
Overrange effect: Zero shift; 0.2% of URL/(1.5 x URL)
Supply voltage effect:
Less than 0.05% of calibrated span per
10V
Less than 0.2% of URL for the frequen-
cies of 20 to 1000MHz and field strength
30 V/m when electronics covers on.
Environmental protection:
RFI effect:
IEC IP67 and NEMA 4X
Mounting:
On 60.5mm (JIS 50A) pipe using mount-
ing bracket, direct wall mounting
Transmitter approximately 10kg without
options.
Add; 0.5kg for mounting bracket
0.8kg for indicator option
4.5kg for stainless steel housing
option
1.5kg per 50mm extension of diaphragm
Step response: Time constant: 0.3s (with 1.5m capillary)
Dead time: approximately 0.3s
(without electrical damping)
Dielectric strength:
500V AC, 50/60Hz 1 min., between circuit
and earth.
Insulation resistance:
Mass {weight}:
More than 100MΩ/500V DC.
Turn-on time:
4 sec.
Internal resistance for external field indicator:
12Ω or less
3
...
FHW, FKW 3
Optional features
ACCESSORIES
Indicator:
A plug-in analog indicator (1.5% accuracy)
Hand-held communicator:
can be housed in the electronics compart-
ment or in the terminal box of the hous-
(Model FXW, refer to Data Sheet No.
EDS8-47)
ing.
Communication module: (Standard for FKW)
1
/
An optional 4 digits LCD meter is also
By adding communication module, re-
2
mote setting function becomes available
available.
for model FHW.
Arrester:
A built-in arrester protects the electronics
from lightning surges.
Lightning surge immunity is 4kV (1.2 x
50µs).
Remark: When the communication module is con-
nected, the operation mode of external
zero/span adjustment screw is limited to
zero adjustment only.
Oxygen service: Special cleaning procedures are followed
throughout the process to maintain all pro-
cess wetted parts oil-free.
The fill fluid is fluorinated oil.
Chlorine service: Oil-free procedures as above. Includes
fluorinated oil for fill.
Not available with material code “W”.
Degreasing:
Process-wetted parts are cleaned, but the
fill fluid is standard silicone oil. Not for use
on oxygen or chlorine measurement.
Vacuum and high temperature service:
Special silicone oil and filling procedure
are applied.
See below figure.
Silicone (Code Y,G)
[kPa abs]
{m bar abs}
Silicone (Code S)
101
{1010}
53.3
{533}
Operating area
13.3
{133}
The product conforms to the requirements of the
Electromagnetic compatibility Directive 89/336/EEC as
detailed within the technical construction file number
TN510412. The applicable standards used to demonstrate
compliance are :-
Non-operating
area
2.7
{27}
EMI (Emission)
EN50081-1 : 1992
–40
0
60 85 120
Process temperature
200 230 250
[°C ]
Test item
Frequency range
Basic standard
Applicable Electro-
magnetic Radiation
Disturbance
EN55022
Class B
30-1000MHz
Fig. 1 Relation between process temperature and
operating pressure
EMS (Immunity) EN50082-1 : 1992
Customer tag:
A stainless steel tag for customer tag data
is wired to the transmitter.
Test
Basic
standard
Performance
criteria
No. Test item
specification
Coating of cell: Cell's surface is finished with epoxy/poly-
urethane double coating. Specify if envi-
ronment is extremely corrosive.
Electrostatic
discharge
1
8kV (Air)
IEC 801-2:1984
IEC 801-3:1984
B
A
Radio-frequency 27-500MHz
electromagnetic 3V/m
field.
2
3
(Unmodulated)
0.5kV, 5/50
(Tr/Th) ns
5kHz Rep.
Fast transients
common mode
IEC 801-4:1988
B
"LVD - The transmitter is not covered by the requirements
of the LVD standard."
4
CODE SYMBOLS
1
2
3
4
5
6
7
8
9
10 11 12 13
14 15 16 17 18 19 20
F
W
3
0
Description
Type
4 to 20mA, Output type
4 to 20mA with digital signal, Output type
FHW
FKW
Conduit connection <4th digit>
G 1/2
1/2 - 14NPT
Pg 13.5
M20 X 1.5
S
T
V
W
Flange <5th digit>
Material
Size and rating
0
1
2
3
4
5
6
7
A
B
C
D
E
F
304 stainless
steel
JIS 10K 40A
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
JIS 63K 40A
JIS 63K 50A
ANSI/JPI 150LB 1 1/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 1 1/2"
ANSI/JPI 300LB 2"
ANSI/JPI 600LB 1 1/2"
ANSI/JPI 600LB 2"
Carbon steel
JIS 10K 40A
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
JIS 63K 40A
JIS 63K 50A
ANSI/JPI 150LB 1 1/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 1 1/2"
ANSI/JPI 300LB 2"
ANSI/JPI 600LB 1 1/2"
ANSI/JPI 600LB 2"
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
None
(Wafer type)
40A, 1 1/2B
50A, 2B
W
X
Direct mounting adapter connection (* 1)
Y
Span limit [kPa] {m bar} <6th digit>
FHW FKW
...
..
...
...
...
...
...
3
4
300 3000 (3 30) 50 3000 ( 0.5 30)
..
1000 10000 (10 100) 250 10000 (2.5 100)
Material/diapharagm extension <7th digit>
Diaphragm extension (mm)
Diaphragm
Flange face
0
50
100
150
316L stainless steel 316 stainless steel
W
A
B
C
D
(*2)
200
0
0
0
Hastelloy-C
Monel
Tantalum
Hastelloy-C
Monel
Tantalum
H
M
T
Note 1: Direct mounting adapter type is specified at 16th to 20th digit.
Direct mounting adapter is available only for 7th digit code "W".
2: Diaphragm extension is available only for 2" (50A) flanges.
5
...
FHW, FKW 3
20
1
2
3
4
5
6
7
8
9
10 11 12 13
14 15 16 17 18 19
F
W
3
Description
Indicator and arrester <9th digit>
Indicator
Arrester
A
B
D
J
E
F
H
K
L
P
Q
S
None
None
None
None
None
Yes
Yes
Yes
Yes
Analog, 0 to 100% linear scale
Analog, custom scale
Analog, double scale
None
Analog, 0 to 100% linear scale
Analog, custom scale
Analog, double scale
Digital, 0 to 100%
Digital, custom scale
Digital, 0 to 100%
Digital, custom scale
None
None (Model FKW only)
Yes
Yes (Model FKW only)
Approvals for hazardous locations <10th digit> (Approval pending)
None (for ordinary locations)
JIS, Flameproof (Conduit seal) (Available for 4th digit code "S")
JIS, Flameproof (Cable gland seal) (Available for 4th digit code "S")
FM, Flameproof (or explosionproof) (Available for 4th digit code "T")
BASEEFA, Flameproof (Conduit seal)
BASEEFA, Flameproof (Cable gland seal) (Conduit connection G 1/2 only)
FM, Intrinsic safety and Nonincendive
CENELEC, Intrinsic safety
A
B
C
D
M
N
H
K
P
CENELEC, Intrinsic safety and BASEEFA, Type N
Capillary and mounting bracket <11th digit>
mounting bracket
Carbon steel
Capillary
A
B
G
1.5m
3m
5m
D
E
L
Stainless steel
1.5m
3m
5m
Stainless steel parts <12th digit>
Stainless steel tag plate Stainless steel elec. housing
Coating of cell
None
None
None
None
Yes
Yes
Yes
Yes
Y
B
C
E
M
N
P
None
Yes
None
Yes
None
None
Yes
Yes
None
Yes
None
Yes
None
None
Yes
Q
Yes
Treatment/Fill fluid <13th digit>
Treatment
Fill fluid
None
None
Degreasing
Oxygen service
Chlorine service
High temp. 250°C
Silicone oil (for general use)
Fluorinated oil
Silicone oil
Y
W
G
A
D
H
S
Fluorinated oil (7th digit code "W", "A", "B", "C" and "D")
Fluorinated oil (7th digit code "H" and "T")
Silicone oil
(7th digit code "W", "A", "B", "C" and "D")
}
High temp. and vacuum (250°C) Silicone oil
Teflon membrane <14th digit>
None
Yes (7th digit code "W", "H", "M", and "T")
Y
C
Bolt/nut <15th digit>
None
6th digit code "3"
6th digit code "4"
Y
A
Standard (Cr-Mo alloy hexagon socket head cap bolt/
carbon steel nut)
Cr-Mo alloy hexagon bolt/carbon steel nut
304 stainless steel bolt/304 stainless steel nut
B
E
Odering information
1. When odering this instrument, specify the output orientation (burnout direction) in case of abnormality in the transmitter.
Unless otherwise specified, the output hold function is supplied.
6
Specifications of Direct Mounting Adapter {for 15, 20A (1/2, 3/4") connection} and others
Note 1. When odering the instrument with direct mounting adapter, specify "Y" in the 5th digit of Code Symbol, and specify
16th digit to 20th digits.
When odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digits.
2. Unless otherwise described in the specifications, leave the 21st digit blank.
1
2
3
4
5
6
7
8
9
10 11 12 13
14 15 16 17 18 19 20
F
W
3
Description
Process connection (direct mounting adapter) <16th to 17 digit>
JIS 10K 15A
JIS 10K 20A
JIS 20K 15A
JIS 20K 20A
JIS 30K 15A
JIS 30K 20A
JIS 63K 15A
JIS 63K 20A
ANSI/JPI 150LB 1/2"
ANSI/JPI 150LB 3/4"
ANSI/JPI 300LB 1/2"
ANSI/JPI 300LB 3/4"
ANSI/JPI 600LB 1/2"
ANSI/JPI 600LB 3/4"
Screw connection Rc1/2
Screw connection Rc3/4
Screw connection Rc1/2 - 14NPT
Screw connection Rc3/4 - 14NPT
1 1
1 2
2 1
2 2
3 1
3 2
6 1
6 2
1 H
1 T
2 H
2 T
4 H
4 T
S R
S 2
S N
S T
Material (direct mounting adapter) <18th digit>
Adapter
Bolts/nuts
(* 1)
W
316 Stainless Steel Cr-Mo steel/carbon steel
Vent/drain (for direct mounting adapter) <19 th digit>
Standard
Long type
G
N
Gasket (for direct mounting adapter) <20th digit>
Standard (Teflon) (Only Y, W, G, A and D can be specified on 13th digit).
For high temperature (spiral gasket) (Only H and S can be specified on
13th digit).
1
2
*1 For connection of transmitter receiving pressure unit and direct mounting adapter
7
...
FHW, FKW 3
Fastener
Zero/span adj. screw
(In case of 10th
digit code “B,C,M,N”)
In case of 4th
digit code “S,V,W,X”
MTG. pipe
JIS 50A (2")
U - bolt M8
Up
Down
30
38
“A”
4 holes
9 dia.
Conduit conn.
224
58
Cable gland
(option)
See note
“B”
Conduit conn.
N holes
h dia.
Inner of gasket
Detail “A”
Conduit conn.)
Detail “B”
φ 13
(
φ 15
Earth terminal
(both side)
See table 1
51
71
191
(27)
20
J
G1/2
t
L
See table 1
With field ind.
(option)
11th digit of Capillary
code symbols length S [mm]
7th digit of
Code symbols
L
Mass approx.
[kg]
W, H, M, T
0
A,D
B, E
G, L
1500
3000
5000
9.5
10.5
11.5
12
A
B
C
D
50
100
150
200
S
2-M8 × 12
12.5
Flange
5th digit of code symbols φ D φ E
t
N-φ h
0, G
1, H
2, J
140 105
155 120
140 105
155 120
160 120
165 130
175 130
185 145
36 4-19
36 4-19
38 4-19
38 8-19
42 4-23
42 8-19
52 4-25
54 8.23
JIS-10K-40A
50
70
JIS-10K-50A
JIS-20K-40A
120
3, K
4, L
5, M
6, N
7, P
A, Q
B, R
C, S
D, T
E, U
F, V
JIS-20K-50A
JIS-30K-40A
JIS-30K-50A
JIS-63K-40A
JIS-63K-50A
Conduit conn.
K
4th digit of
Code symbols
Earth terminal
127 98.4 37.5 4-16
152 120.6 39.5 4-20
156 114.3 41 4-23
165 127 42.5 8-20
156 114.3 42.5 4-23
165 127 45.5 8-20
ANSI/JPI-150LB-1 1/2"
ANSI/JPI-150LB-2"
ANSI/JPI-300LB-1 1/2"
ANSI/JPI-300LB-2"
ANSI/JPI-600LB-1 1/2"
ANSI/JPI-600LB-2"
J
M
S
T
No. 8-32UNC
G1/2
17
8
M4
M4
M4
1/2-14NPT 16
5
V
Pg13.5
8
4.5
5
M20x1.5
16
W
Note *: Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
Table 1
CONNECTION DIAGRAM
<Optional stainless steel tag>
2-M6 screw depth 9
Inner of gasket
–
+
CK+ CK–
+
–
φ
φ
0
1
2
3
4
5
6
20
S
H
K
T
V
20
3
F
W
Note: In case of wafer type, flange is excluded
from the scope of supply.
W
<Wafer type>
Mount flange, referring to the view.
8
OUTLINE DIAGRAM (Unit:mm)
Zero/span adj. screw
Fastener
(In case of 10th
digit code “B,C,M,N”)
In case of 4th
digit code “S,V,W,X”
MTG. pipe
JIS 50A (2")
U - bolt M8
Up
Down
30
38
“A”
Conduit conn.
4 holes
9 dia.
224
58
Cable gland
(option)
See note
“B”
Conduit conn.
Specifications for instrument with
direct mounting adapter
80
20
N holes H dia.
t
Detail “A”
Conduit conn.)
Detail “B”
φ 13
S
(
φ 15
J
G1/2
(6.4) In case of
ANSI/JPI-600LB flange
See table
1
(T) In case of
ANSI/JPI-600LB flange
With field ind.
(option)
Earth terminal
(both side)
See table 1
Vent/drain plug
51
71
191
(27)
Long vent/drain plug
(added specification)
Table 1
Conduit conn.
K
4th digit of
Code symbols
S
11th digit of
code symbols
Earth terminal
S
J
M
A,D
B, E
G, L
1500
3000
5000
M4
No. 8-32UNC
M4
G1/2
17
8
T
V
1/2-14NPT 16
5
Pg13.5
8
4.5
5
2-M8 × 12
M4
W
M20x1.5
16
16th digit of 17th digit of
code symbols code symbols
øD
95
øE
70
øF
t
N-øh
Flange
50
70
1
1
2
2
3
3
6
6
1
1
2
2
4
4
1
2
1
2
1
2
1
2
H
T
H
T
H
T
51
56
51
56
55
60
55
60
12
14
14
16
18
18
23
25
4-15 JIS-10K-15A
4-15 JIS-10K-20A
4-15 JIS-20K-15A
4-15 JIS-20K-20A
4-19 JIS-30K-15A
4-19 JIS-30K-20A
4-19 JIS-63K-15A
4-23 JIS-63K-20A
120
100 75
95 70
100 75
115 80
120 85
120 85
135 95
CONNECTION DIAGRAM
–
+
CK+ CK–
+
–
89
98
95
60.3 34.9 11.5 4-16 ANSI/JPI-150LB-1/2"
69.9 42.9 13 4-16 ANSI/JPI-150LB-3/4"
66.7 34.9 14.5 4-16 ANSI/JPI-300LB-1/2"
4-20 ANSI/JPI-300LB-3/4"
66.7 34.9 14.5 4-16 ANSI/JPI-600LB-1/2"
117 82.5 42.9 16 4-20 ANSI/JPI-600LB-3/4"
1
2
3
4
6
S
T
V
W
H
K
3
F
W
Y
117 82.5 42.9 16
95
Note *: Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
9
...
FHW, FKW 3
OUTLINE DIAGRAM (Unit:mm)
Fastener
(In case of 10th
digit code “B,C,M,N”)
Zero/span adj. screw
In case of 4th
digit code “S,V,W,X”
MTG. pipe
JIS 50A (2")
U - bolt M8
UP
DOWN
30
38
“A”
4 holes
9 dia.
Conduit conn.
224
58
Cable gland
(option)
See note
Detail “A”
(Contuit conn.)
Detail “B”
“B”
Conduit
conn.
φ 13
φ 15
23
20
J
G1/2
See table 1
S
With field ind.
(option)
Earth terminal
(both side)
See table 1
Press. conn. "D"
51
71
191
(27)
Long vent/drain plug
Long vent/drain plug
(option)
Specifications for instrument
with direct mounting adapter
(screw connection type)
2-M8 × 12
Table 1
Conduit conn.
11th digit of
code symbols
4th digit of
Code symbols
S
Earth terminal
S
J
K
M
50
70
A,D
B, E
G, L
1500
3000
5000
M4
No. 8-32UNC
M4
G1/2
17
8
120
T
V
1/2-14NPT 16
5
Pg13.5
8
4.5
5
M4
W
M20x1.5
16
CONNECTION DIAGRAM
Press. conn. "D"
16th digit of code symbols 17th digit of code symbols
–
+
CK+ CK–
Rc 1/2
S
S
S
S
R
N
2
1/2 - 14NPT
Rc 3/4
+
–
S
T
H
F
3/4 - 14NPT
T
Y
3
S
W
K
V
Note *: Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
W
Head office
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo 191-8502 Japan
Phone: 81-42-585-6201, 6202
11-2 Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032 Japan
Phone: 81-3-5435-7111
http://www. fujielectric.co.jp/eng/sg/KEISOKU/welcome.htm
Fax: 81-42-585-6187, 6189
Printed in Japan
Information in this catalog is subject to change without notice.