GHT2V060MHERGT002 [GALAXY]
TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter; TAURUS HC系列业内最高效率的DC / DC转换器型号: | GHT2V060MHERGT002 |
厂家: | GALAXY POWER, INC. |
描述: | TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter |
文件: | 总8页 (文件大小:910K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TAURUS HC Series
Industry’s Highest Efficiency DC/DC Converter
48V or 24V Input, 1.2V, 1.5V, 1.8V, 2.0V, 2.5V, 3.3VDC, 60A Output or 1.2V,
1.5V, 1.8V, 2.0V, 2.5V, 3.3V, 5.0VDC, 40A Output or 5.0VDC, 30A Output
The High Current Taurus half brick is
another CoolConverter in the Galaxy
™
family of high-efficiency DC/DC converters.
Industry Standard Pinout and Footprint
Typical Efficiency:
93% at 3.3V, 30A; 92% at 3.3V, 60A
No Heat Sink Required
Very Low Common-mode Noise for a
Commercial DC/DC Converter
Two-stage Input Filter
Constant Switching Frequency
Remote Sense
Single Board Design
Optional Baseplate or Low Profile Heatsink
for Improved Thermal Performance
Header with M3 Metal Inserts for Mechanical
Connection to PCB
The open-frame Taurus HC
is also available with a heat-spreading
baseplate or complete with an optional
heatsink.
Two Year Warranty
Control Functions
Uses Patented Power Supply Control
and Architecture
Microprocessor Controlled
Primary-side Enable, Choice of Logic
Protection Features
Over Temperature Protection
Over Voltage Protection
Over/Under Input Voltage Protection
Over Current Protection
Typical Characteristics
Output Setpoint Accuracy: ±1%
Load Regulation: ±0.25%
Line Regulation: ±0.25%
Regulation over Line, Load, and Temperature: ±2%
Output Trim
Taurus HC Series, Page 1
Part No. 01–001 Rev. 4.0_082803
WWW.GALAXYPWR.COM
General Specifications
V
= 48V , T @25 °C, 300 LFM airflow, V
=3.3V, I
= Full Load unless otherwise noted.
OUT
IN
DC
A
OUT
Available output power depends on ambient temperature and good thermal management. (See application graphs for limits.)
Input Characteristics
Parameter
Min
Typ
Max
75
Units
Operating Input Voltage
36
48
V
DC
Input Current (Model Dependent)
Input Capacitance
8.0
A
6.6
2
µF
Input Hysteresis, Low Line
Output Characteristics
V
DC
Regulation Over Line, Load & Temperature
98
102
25
%V
mV
mV
NOM
RMS
P–P
Voltage Ripple
Voltage Ripple, 20MHz BW
Current Range
125
60
0
A
Current Limit Inception
62
72
A
A
Short Circuit Current, Peak (see Note below)
Output Transient Response, 50% to 75% load change, 1A/µsec
Settling Time to ±1%
75
125
300
30
mV
µS
mS
Turn-on Time to 98% Vnom
Output Overshoot at Turn-on
Trim Range
1
%V
OUT
OUT
OUT
90
110
%V
%V
Overvoltage Protection, Latching
130
200
Isolation
Isolation Test Voltage, Input/Output (Basic)
Isolation Resistance
2000
10
V
DC
MΩ
Features
Overtemperature Protection, Thermal Sensor, Latching*
117
°C
Input, Output Ripple Frequency, Fixed**
kHz
Notes: During short circuit, converter will shut down and attempt to restart once per second.
The average current during this condition will be very low and the device can be safely left in this condition
continuously. For specific output voltage specifications, see the corresponding detailed data sheet.
*PCB less than 130°C
**3V360 = 300kHz
General Specifications
Approvals and Standards
Operating Temperature
Storage Temperature
Relative Humidity
-40°C to +100°C
–55°C to +125°C
10% to 95% RH,
Non-condensing
2 to 9Hz, 3mm disp.
9 to 200Hz 1g
UL V-0
UL and c-UL Recognized Component,
TUV, UL60950, CSA 22.2 No. 950,
IEC/EN60950**
EMC Characteristics:
Vibration
Designed to meet emission and immunity
requirements per EN55022, CISPR22,
Class B and CISPR24.
Material Flammability
Weight
55 grams
** An external fuse shall be used to comply with the requirements.
MTBF
Telcordia (Bellcore)
1,300,000 hours
Taurus HC Series, Page 2
Part No. 01–001 Rev. 4.0_082803
WWW.GALAXYPWR.COM
Application Notes
CoolConverter™ Family
™
Galaxy’s COOLCONVERTER Family features:
• Patented single-stage power conversion architecture, control,
and magnetic design allow unprecedented power density and
efficiency in an isolated power supply.
• An advanced microcontroller reduces parts count while
adding features, performance, and flexibility in the design.
• Low common-mode noise as a result of lower capacitance in
the transformer compared to planar magnetics and metal
baseplate designs.
• Higher reliability than planar transformer designs that can
suffer from via fatigue from thermal cycling, and metal
baseplate designs with board to board interconnects that are
subject to mechanical stress on electrical connections.
Protection and Control
Valid Input Voltage Range:
The converter measures the input voltage and will
not allow operation outside of the input voltage
specification. As shown by the graphs, hysteresis is
added to both the high and low voltage to prevent
the converter from turning on and off repeatedly
when the voltage is held near either voltage
extreme. At low line this assures the maximum
input current is not exceeded; at high line this
assures the semiconductor devices in the converter
are not damaged by excessive voltage stress.
ON/OFF Logic Option:
The ON/OFF control logic can be either Negative
(standard) or Positive to enable the converter. For
Negative logic, the ON/OFF pin is brought below
1.0V with respect to the -INPUT pin to enable the
converter. The pull-down must be able to sink
100µA. For Positive logic, the ON/OFF pin is
brought to greater than 4.0V with respect to the
–INPUT pin and be limited to less than 10V. To
request the Positive logic version, add the suffix (P)
to the standard part number. The ON/OFF pin has a
built-in pull-up resistor of approximately 100kΩ to
+5V.
Taurus HC Series, Page 3
Part No. 01–001 Rev. 4.0_082803
WWW.GALAXYPWR.COM
APPLICATION NOTES
Output Over Voltage Protection:
Trim:
The output voltage is constantly monitored by the
microprocessor and a redundant secondary side
crowbar circuit that is set to a higher trip point than
the microprocessor protection. If the output voltage
exceeds the over-voltage specification, the
To trim the output voltage higher, connect the
required trim resistor from the Trim pin to the
+Sense pin. To trim the output voltage lower,
connect the required trim resistor from the Trim pin
to the –Sense pin. See diagram below.
microprocessor will latch the converter off. To turn
the converter on requires either cycling the ON/
OFF pin or power to the converter. This advanced
feature prevents the converter from damaging the
load if there is a converter failure or application
error. If non-latching is required, consult factory.
Trim-down
Thermal Shutdown:
The printed circuit board temperature is measured
using a semiconductor sensor. If the maximum
rated temperature is exceeded, the converter is
latched off. To re-enable the converter requires
cycling the ON/OFF pin or power to the converter.
If non-latching shutdown is required, consult
factory.
Trim-down (%)
100
RTRIM-DOWN
=
– 2 kΩ
{∆% }
Control Options:
As the behavior of the circuit is determined by
firmware in the microcontroller, specific customer
requirements such as:
Trim-up (for 3.3V)
• non-latching thermal protection
• custom valid input voltage range
• controlled delay from initiating an ON/OFF
signal for power sequencing
can be accomplished with no change to hardware.
The standard behavior was chosen based on
system design experience but we understand that
customers often have their own requirements.
Please consult Galaxy Power for your special
needs.
Remote Sense:
The output voltage is regulated at the point where
the sense pins connect to the power output pins.
Total sense compensation should not exceed 0.4V
or 10% of Vout, whichever is greater.
Vo (100+∆%)
(100+2∆%)
RTRIM-UP
=
–
kΩ
{
}
1.225∆%
∆%
External Output Trimming
+ Sense
Safety:
An external input fuse must always be used to
meet these safety requirements.
Trim
– Sense
Taurus HC Series, Page 4
Part No. 01–001 Rev. 4.0_082803
WWW.GALAXYPWR.COM
GHTW3V360 OPERATION
Efficiency
Power Dissipation
94
92
90
88
86
84
82
80
30
25
20
15
10
36V
48V
75V
36V
48V
75V
5
0
60
0
10
20
30
50
40
60
0
10
20
30
50
40
Load Current (A)
Load Current (A)
Transient Response
Voltage Ripple
[
]
Ch1 Pk–Pk
104.0mV
Ch1 RMS
16.38mV
Vout
Vout
20A
Iout
10A
20.0mV
4
38
Start-up Waveform
Thermal Derating Curves
GHTW3V360 Heatsink Ready
60
T
50
40
30
20
10
0
Ch1 +Over
1.042%
Ch1 High
2.300V
1
Vout
Ch1 Max
2.324V
100 LFM
200 LFM
300 LFM
400 LFM
600 LFM
Enable
2
B
W Ch2 5.00 V
M
4.00ms A Ch2
3.00V
Ch1 1.00mV
10
20
30
40
50
60
70
80
90
Ambient Air Temperature (deg C)
Taurus HC Series, Page 5
Part No. 01–001 Rev. 4.0_082803
WWW.GALAXYPWR.COM
Package Detail
2.28
MOUNTING INSERT
CONNECTED TO CASE PIN
Pin Configuration —Bottom View
2.000
Pin No.
Function
– Input
Pin Dia. (in.)
0.040
0.040
0.040
0.040
0.080
0.080
0.040
0.040
0.040
0.080
0.080
1.700
PIN 11
2.000
1
2*
3
4
5
6*
7
8
9
10*
11
1.500 PIN 10 *
B
B
A
Case Pin
On/Off
1.700
PIN 1
PIN 9
PIN 8
1.300
1.000
(CASE)
A
* PIN 2 1.300
+ Input
+ Output
+ Output
+ Sense
Trim
– Sense
– Output
– Output
A
2.40
.700 PIN 7
.500 PIN 6 *
.300 PIN 5
0
A
A
.700
PIN 3
PIN 4
B
B
.300
0
MOUNTING INSERT
M3 X 0.5 4 PLACES
.20
BOTTOM VIEW
.19
*NON-STANDARD PIN OUT
Notes:
1. “A” = 0.040 dia. pins
2. “B” = 0.080 dia. pins
3. Optional pins marked*
4. Mechanical tolerances
x.xxx in. = ±0.005 in.
x.xx in. = ±0.01 in.
5. Pin material: brass with tin/lead plating over nickel
6. Workmanship:
.20
0
.50
.010 .008
.50
SIDE VIEW
Meets or exceeds IPC-A-610B Class II
Taurus HC Series, Page 6
Part No. 01–001 Rev. 4.0_082803
WWW.GALAXYPWR.COM
ORDERING INFORMATION
Standard Model
Number
Output
Voltage
Max
Typical Efficiency
Standard Model
Output
Voltage
Max
Typical Efficiency
Half Load Full Load
Current
Half Load Full Load
Number
Current
48V Input Models (Designated W)
24V Input Models (Designated C)
GHTW5V040*
GHTW3V360*
GHTW2V560*
GHTW2V060*
GHTW1V860*
GHTW1V560*
GHTW1V260*
GHTW5V030*
GHTW3V340*
GHTW2V540*
GHTW2V040*
GHTW1V840*
GHTW1V540*
GHTW1V240*
5.0V
3.3V
2.5V
2.0V
1.8V
1.5V
1.2V
5.0V
3.3V
2.5V
2.0V
1.8V
1.5V
1.2V
40A
60A
60A
60A
60A
60A
60A
30A
40A
40A
40A
40A
40A
40A
93%
92%
90%
90%
89%
87%
86%
93%
93%
91%
90%
89%
88%
87%
91%
89%
88%
85%
84%
83%
80%
90%
91%
88%
86%
84%
83%
82%
GHTC5V040*
GHTC3V360*
GHTC2V560*
GHTC2V060*
GHTC1V860*
GHTC1V560*
GHTC1V260*
GHTC5V030*
GHTC3V340*
GHTC2V540*
GHTC2V040*
GHTC1V840*
GHTC1V540*
GHTC1V240*
* Options:
5.0V
3.3V
2.5V
2.0V
1.8V
1.5V
1.2V
5.0V
3.3V
2.5V
2.0V
1.8V
1.5V
1.2V
40A
60A
60A
60A
60A
60A
60A
30A
40A
40A
40A
40A
40A
40A
91%
91%
89%
89%
88%
86%
83%
91%
92%
90%
89%
88%
87%
86%
88%
87%
85%
83%
82%
81%
78%
88%
90%
87%
85%
83%
82%
81%
Ordering Information
P = Positive Logic Version; High = On
Example Part No.:
H = Extra Power Pins, Non-standard Pinout
E = 0.18" Pins (±.01")
M = 0.145" Pins (±.01")
S = 0.12" Pins (±.01")
RG = Heatsink Ready (incl. Plate + Case Ground Pin),
or with heatsink:
G00X = Case Ground Pin + Heatsink
T = Tuned model**
Heatsinks optional, consult factory.
GHTW2V560MRGT
48V input
2.5V @ 60A output
Negative Logic
0.145" pin length
Case Ground Pin
Heatsink-ready Plate
Tuned Module
Options Code: (All options shown)
Taurus/Taurus HC Heatsink Part Numbers
GHTW 3V3 60 P H S R G T 00X
Part
Typical Thermal Performance
Part Number
Number
Height
Natural Convection
Forced Convection
(from chart above)
Options:
Power Dissipation†
Thermal Resistance††
001
002
003
004
0.24"
0.45"
0.95"
0.13"
5W
5.8°C/W
3.2°C/W
2.0°C/W
TBD
Positive Logic Version
Extra Power Pins
Optional Pin Length
E = 0.18"
7W
11W
TBD
M = 0.145"
S = 0.12"
Heatsink-ready plate (requires G)
Case Ground Pin
Tuned Model
**T (Tuned Model) Option
Designed for higher di/dt and ∆I applications, the
transient response has been modified to take
advantage of the capacitance on the customer's
PCB. This unit requires a minimum load
capacitance of 5600µF with an impedance
magnitude of less than 0.005Ω at 15kHz. It offers a
minimum 3X improvement in the peak response
compared to a standard unit.
Heatsink (does not require R, must have G)
001 = 0.25"
002 = 0.50"
003 = 1.00"
004 = 0.13"
Taurus HC Series, Page 7
Part No. 01–001 Rev. 4.0_082803
WWW.GALAXYPWR.COM
Galaxy Power Inc. warrants to the original purchaser that the products
conform to this data sheet and are free from material and workmanship
defects for a period of two (2) years from the date of manufacture, if this
product is used within specified conditions. Galaxy Power Inc. reserves the
right to make changes to the product(s) or information contained herein
without notice. No liability is assumed as a result of their use or application.
No rights under any patent accompany the sale of any such products or
information. For additional details on this limited warranty consult the
factory.
155 Flanders Road Westborough, MA 01581
508-870-9775 Fax: 508-870-9796
e–mail: info@galaxypwr.com
website: http://www.galaxypwr.com
© Copyright 2000 Galaxy Power. Specifications subject to change without notice.
Taurus HC Series, Page 8
Part No. 01–001 Rev. 4.0_082803
WWW.GALAXYPWR.COM