GHT2V060MHERGT002 [GALAXY]

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter; TAURUS HC系列业内最高效率的DC / DC转换器
GHT2V060MHERGT002
型号: GHT2V060MHERGT002
厂家: GALAXY POWER, INC.    GALAXY POWER, INC.
描述:

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
TAURUS HC系列业内最高效率的DC / DC转换器

转换器
文件: 总8页 (文件大小:910K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TAURUS HC Series  
Industry’s Highest Efficiency DC/DC Converter  
48V or 24V Input, 1.2V, 1.5V, 1.8V, 2.0V, 2.5V, 3.3VDC, 60A Output or 1.2V,  
1.5V, 1.8V, 2.0V, 2.5V, 3.3V, 5.0VDC, 40A Output or 5.0VDC, 30A Output  
The High Current Taurus half brick is  
another CoolConverter in the Galaxy  
family of high-efficiency DC/DC converters.  
Industry Standard Pinout and Footprint  
Typical Efficiency:  
93% at 3.3V, 30A; 92% at 3.3V, 60A  
No Heat Sink Required  
Very Low Common-mode Noise for a  
Commercial DC/DC Converter  
Two-stage Input Filter  
Constant Switching Frequency  
Remote Sense  
Single Board Design  
Optional Baseplate or Low Profile Heatsink  
for Improved Thermal Performance  
Header with M3 Metal Inserts for Mechanical  
Connection to PCB  
The open-frame Taurus HC  
is also available with a heat-spreading  
baseplate or complete with an optional  
heatsink.  
Two Year Warranty  
Control Functions  
Uses Patented Power Supply Control  
and Architecture  
Microprocessor Controlled  
Primary-side Enable, Choice of Logic  
Protection Features  
Over Temperature Protection  
Over Voltage Protection  
Over/Under Input Voltage Protection  
Over Current Protection  
Typical Characteristics  
Output Setpoint Accuracy: ±1%  
Load Regulation: ±0.25%  
Line Regulation: ±0.25%  
Regulation over Line, Load, and Temperature: ±2%  
Output Trim  
Taurus HC Series, Page 1  
Part No. 01–001 Rev. 4.0_082803  
WWW.GALAXYPWR.COM  
General Specifications  
V
= 48V , T @25 °C, 300 LFM airflow, V  
=3.3V, I  
= Full Load unless otherwise noted.  
OUT  
IN  
DC  
A
OUT  
Available output power depends on ambient temperature and good thermal management. (See application graphs for limits.)  
Input Characteristics  
Parameter  
Min  
Typ  
Max  
75  
Units  
Operating Input Voltage  
36  
48  
V
DC  
Input Current (Model Dependent)  
Input Capacitance  
8.0  
A
6.6  
2
µF  
Input Hysteresis, Low Line  
Output Characteristics  
V
DC  
Regulation Over Line, Load & Temperature  
98  
102  
25  
%V  
mV  
mV  
NOM  
RMS  
P–P  
Voltage Ripple  
Voltage Ripple, 20MHz BW  
Current Range  
125  
60  
0
A
Current Limit Inception  
62  
72  
A
A
Short Circuit Current, Peak (see Note below)  
Output Transient Response, 50% to 75% load change, 1A/µsec  
Settling Time to ±1%  
75  
125  
300  
30  
mV  
µS  
mS  
Turn-on Time to 98% Vnom  
Output Overshoot at Turn-on  
Trim Range  
1
%V  
OUT  
OUT  
OUT  
90  
110  
%V  
%V  
Overvoltage Protection, Latching  
130  
200  
Isolation  
Isolation Test Voltage, Input/Output (Basic)  
Isolation Resistance  
2000  
10  
V
DC  
M  
Features  
Overtemperature Protection, Thermal Sensor, Latching*  
117  
°C  
Input, Output Ripple Frequency, Fixed**  
kHz  
Notes: During short circuit, converter will shut down and attempt to restart once per second.  
The average current during this condition will be very low and the device can be safely left in this condition  
continuously. For specific output voltage specifications, see the corresponding detailed data sheet.  
*PCB less than 130°C  
**3V360 = 300kHz  
General Specifications  
Approvals and Standards  
Operating Temperature  
Storage Temperature  
Relative Humidity  
-40°C to +100°C  
–55°C to +125°C  
10% to 95% RH,  
Non-condensing  
2 to 9Hz, 3mm disp.  
9 to 200Hz 1g  
UL V-0  
UL and c-UL Recognized Component,  
TUV, UL60950, CSA 22.2 No. 950,  
IEC/EN60950**  
EMC Characteristics:  
Vibration  
Designed to meet emission and immunity  
requirements per EN55022, CISPR22,  
Class B and CISPR24.  
Material Flammability  
Weight  
55 grams  
** An external fuse shall be used to comply with the requirements.  
MTBF  
Telcordia (Bellcore)  
1,300,000 hours  
Taurus HC Series, Page 2  
Part No. 01–001 Rev. 4.0_082803  
WWW.GALAXYPWR.COM  
Application Notes  
CoolConverterFamily  
Galaxy’s COOLCONVERTER Family features:  
• Patented single-stage power conversion architecture, control,  
and magnetic design allow unprecedented power density and  
efficiency in an isolated power supply.  
• An advanced microcontroller reduces parts count while  
adding features, performance, and flexibility in the design.  
• Low common-mode noise as a result of lower capacitance in  
the transformer compared to planar magnetics and metal  
baseplate designs.  
• Higher reliability than planar transformer designs that can  
suffer from via fatigue from thermal cycling, and metal  
baseplate designs with board to board interconnects that are  
subject to mechanical stress on electrical connections.  
Protection and Control  
Valid Input Voltage Range:  
The converter measures the input voltage and will  
not allow operation outside of the input voltage  
specification. As shown by the graphs, hysteresis is  
added to both the high and low voltage to prevent  
the converter from turning on and off repeatedly  
when the voltage is held near either voltage  
extreme. At low line this assures the maximum  
input current is not exceeded; at high line this  
assures the semiconductor devices in the converter  
are not damaged by excessive voltage stress.  
ON/OFF Logic Option:  
The ON/OFF control logic can be either Negative  
(standard) or Positive to enable the converter. For  
Negative logic, the ON/OFF pin is brought below  
1.0V with respect to the -INPUT pin to enable the  
converter. The pull-down must be able to sink  
100µA. For Positive logic, the ON/OFF pin is  
brought to greater than 4.0V with respect to the  
–INPUT pin and be limited to less than 10V. To  
request the Positive logic version, add the suffix (P)  
to the standard part number. The ON/OFF pin has a  
built-in pull-up resistor of approximately 100kto  
+5V.  
Taurus HC Series, Page 3  
Part No. 01–001 Rev. 4.0_082803  
WWW.GALAXYPWR.COM  
APPLICATION NOTES  
Output Over Voltage Protection:  
Trim:  
The output voltage is constantly monitored by the  
microprocessor and a redundant secondary side  
crowbar circuit that is set to a higher trip point than  
the microprocessor protection. If the output voltage  
exceeds the over-voltage specification, the  
To trim the output voltage higher, connect the  
required trim resistor from the Trim pin to the  
+Sense pin. To trim the output voltage lower,  
connect the required trim resistor from the Trim pin  
to the –Sense pin. See diagram below.  
microprocessor will latch the converter off. To turn  
the converter on requires either cycling the ON/  
OFF pin or power to the converter. This advanced  
feature prevents the converter from damaging the  
load if there is a converter failure or application  
error. If non-latching is required, consult factory.  
Trim-down  
Thermal Shutdown:  
The printed circuit board temperature is measured  
using a semiconductor sensor. If the maximum  
rated temperature is exceeded, the converter is  
latched off. To re-enable the converter requires  
cycling the ON/OFF pin or power to the converter.  
If non-latching shutdown is required, consult  
factory.  
Trim-down (%)  
100  
RTRIM-DOWN  
=
– 2 kΩ  
{% }  
Control Options:  
As the behavior of the circuit is determined by  
firmware in the microcontroller, specific customer  
requirements such as:  
Trim-up (for 3.3V)  
• non-latching thermal protection  
• custom valid input voltage range  
• controlled delay from initiating an ON/OFF  
signal for power sequencing  
can be accomplished with no change to hardware.  
The standard behavior was chosen based on  
system design experience but we understand that  
customers often have their own requirements.  
Please consult Galaxy Power for your special  
needs.  
Remote Sense:  
The output voltage is regulated at the point where  
the sense pins connect to the power output pins.  
Total sense compensation should not exceed 0.4V  
or 10% of Vout, whichever is greater.  
Vo (100+%)  
(100+2%)  
RTRIM-UP  
=
kΩ  
{
}
1.225%  
%  
External Output Trimming  
+ Sense  
Safety:  
An external input fuse must always be used to  
meet these safety requirements.  
Trim  
– Sense  
Taurus HC Series, Page 4  
Part No. 01–001 Rev. 4.0_082803  
WWW.GALAXYPWR.COM  
GHTW3V360 OPERATION  
Efficiency  
Power Dissipation  
94  
92  
90  
88  
86  
84  
82  
80  
30  
25  
20  
15  
10  
36V  
48V  
75V  
36V  
48V  
75V  
5
0
60  
0
10  
20  
30  
50  
40  
60  
0
10  
20  
30  
50  
40  
Load Current (A)  
Load Current (A)  
Transient Response  
Voltage Ripple  
[
]
Ch1 Pk–Pk  
104.0mV  
Ch1 RMS  
16.38mV  
Vout  
Vout  
20A  
Iout  
10A  
20.0mV  
4
38  
Start-up Waveform  
Thermal Derating Curves  
GHTW3V360 Heatsink Ready  
60  
T
50  
40  
30  
20  
10  
0
Ch1 +Over  
1.042%  
Ch1 High  
2.300V  
1
Vout  
Ch1 Max  
2.324V  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
600 LFM  
Enable  
2
B
W Ch2 5.00 V  
M
4.00ms A Ch2  
3.00V  
Ch1 1.00mV  
10  
20  
30  
40  
50  
60  
70  
80  
90  
Ambient Air Temperature (deg C)  
Taurus HC Series, Page 5  
Part No. 01–001 Rev. 4.0_082803  
WWW.GALAXYPWR.COM  
Package Detail  
2.28  
MOUNTING INSERT  
CONNECTED TO CASE PIN  
Pin Configuration —Bottom View  
2.000  
Pin No.  
Function  
– Input  
Pin Dia. (in.)  
0.040  
0.040  
0.040  
0.040  
0.080  
0.080  
0.040  
0.040  
0.040  
0.080  
0.080  
1.700  
PIN 11  
2.000  
1
2*  
3
4
5
6*  
7
8
9
10*  
11  
1.500 PIN 10 *  
B
B
A
Case Pin  
On/Off  
1.700  
PIN 1  
PIN 9  
PIN 8  
1.300  
1.000  
(CASE)  
A
* PIN 2 1.300  
+ Input  
+ Output  
+ Output  
+ Sense  
Trim  
– Sense  
– Output  
– Output  
A
2.40  
.700 PIN 7  
.500 PIN 6 *  
.300 PIN 5  
0
A
A
.700  
PIN 3  
PIN 4  
B
B
.300  
0
MOUNTING INSERT  
M3 X 0.5 4 PLACES  
.20  
BOTTOM VIEW  
.19  
*NON-STANDARD PIN OUT  
Notes:  
1. “A” = 0.040 dia. pins  
2. “B” = 0.080 dia. pins  
3. Optional pins marked*  
4. Mechanical tolerances  
x.xxx in. = ±0.005 in.  
x.xx in. = ±0.01 in.  
5. Pin material: brass with tin/lead plating over nickel  
6. Workmanship:  
.20  
0
.50  
.010 .008  
.50  
SIDE VIEW  
Meets or exceeds IPC-A-610B Class II  
Taurus HC Series, Page 6  
Part No. 01–001 Rev. 4.0_082803  
WWW.GALAXYPWR.COM  
ORDERING INFORMATION  
Standard Model  
Number  
Output  
Voltage  
Max  
Typical Efficiency  
Standard Model  
Output  
Voltage  
Max  
Typical Efficiency  
Half Load Full Load  
Current  
Half Load Full Load  
Number  
Current  
48V Input Models (Designated W)  
24V Input Models (Designated C)  
GHTW5V040*  
GHTW3V360*  
GHTW2V560*  
GHTW2V060*  
GHTW1V860*  
GHTW1V560*  
GHTW1V260*  
GHTW5V030*  
GHTW3V340*  
GHTW2V540*  
GHTW2V040*  
GHTW1V840*  
GHTW1V540*  
GHTW1V240*  
5.0V  
3.3V  
2.5V  
2.0V  
1.8V  
1.5V  
1.2V  
5.0V  
3.3V  
2.5V  
2.0V  
1.8V  
1.5V  
1.2V  
40A  
60A  
60A  
60A  
60A  
60A  
60A  
30A  
40A  
40A  
40A  
40A  
40A  
40A  
93%  
92%  
90%  
90%  
89%  
87%  
86%  
93%  
93%  
91%  
90%  
89%  
88%  
87%  
91%  
89%  
88%  
85%  
84%  
83%  
80%  
90%  
91%  
88%  
86%  
84%  
83%  
82%  
GHTC5V040*  
GHTC3V360*  
GHTC2V560*  
GHTC2V060*  
GHTC1V860*  
GHTC1V560*  
GHTC1V260*  
GHTC5V030*  
GHTC3V340*  
GHTC2V540*  
GHTC2V040*  
GHTC1V840*  
GHTC1V540*  
GHTC1V240*  
* Options:  
5.0V  
3.3V  
2.5V  
2.0V  
1.8V  
1.5V  
1.2V  
5.0V  
3.3V  
2.5V  
2.0V  
1.8V  
1.5V  
1.2V  
40A  
60A  
60A  
60A  
60A  
60A  
60A  
30A  
40A  
40A  
40A  
40A  
40A  
40A  
91%  
91%  
89%  
89%  
88%  
86%  
83%  
91%  
92%  
90%  
89%  
88%  
87%  
86%  
88%  
87%  
85%  
83%  
82%  
81%  
78%  
88%  
90%  
87%  
85%  
83%  
82%  
81%  
Ordering Information  
P = Positive Logic Version; High = On  
Example Part No.:  
H = Extra Power Pins, Non-standard Pinout  
E = 0.18" Pins (±.01")  
M = 0.145" Pins (±.01")  
S = 0.12" Pins (±.01")  
RG = Heatsink Ready (incl. Plate + Case Ground Pin),  
or with heatsink:  
G00X = Case Ground Pin + Heatsink  
T = Tuned model**  
Heatsinks optional, consult factory.  
GHTW2V560MRGT  
48V input  
2.5V @ 60A output  
Negative Logic  
0.145" pin length  
Case Ground Pin  
Heatsink-ready Plate  
Tuned Module  
Options Code: (All options shown)  
Taurus/Taurus HC Heatsink Part Numbers  
GHTW 3V3 60 P H S R G T 00X  
Part  
Typical Thermal Performance  
Part Number  
Number  
Height  
Natural Convection  
Forced Convection  
(from chart above)  
Options:  
Power Dissipation†  
Thermal Resistance††  
001  
002  
003  
004  
0.24"  
0.45"  
0.95"  
0.13"  
5W  
5.8°C/W  
3.2°C/W  
2.0°C/W  
TBD  
Positive Logic Version  
Extra Power Pins  
Optional Pin Length  
E = 0.18"  
7W  
11W  
TBD  
M = 0.145"  
S = 0.12"  
Heatsink-ready plate (requires G)  
Case Ground Pin  
Tuned Model  
**T (Tuned Model) Option  
Designed for higher di/dt and I applications, the  
transient response has been modified to take  
advantage of the capacitance on the customer's  
PCB. This unit requires a minimum load  
capacitance of 5600µF with an impedance  
magnitude of less than 0.005at 15kHz. It offers a  
minimum 3X improvement in the peak response  
compared to a standard unit.  
Heatsink (does not require R, must have G)  
001 = 0.25"  
002 = 0.50"  
003 = 1.00"  
004 = 0.13"  
Taurus HC Series, Page 7  
Part No. 01–001 Rev. 4.0_082803  
WWW.GALAXYPWR.COM  
Galaxy Power Inc. warrants to the original purchaser that the products  
conform to this data sheet and are free from material and workmanship  
defects for a period of two (2) years from the date of manufacture, if this  
product is used within specified conditions. Galaxy Power Inc. reserves the  
right to make changes to the product(s) or information contained herein  
without notice. No liability is assumed as a result of their use or application.  
No rights under any patent accompany the sale of any such products or  
information. For additional details on this limited warranty consult the  
factory.  
155 Flanders Road Westborough, MA 01581  
508-870-9775 Fax: 508-870-9796  
e–mail: info@galaxypwr.com  
website: http://www.galaxypwr.com  
© Copyright 2000 Galaxy Power. Specifications subject to change without notice.  
Taurus HC Series, Page 8  
Part No. 01–001 Rev. 4.0_082803  
WWW.GALAXYPWR.COM  

相关型号:

GHT2V060MHERGT003

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060MHMRGT001

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060MHMRGT002

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060MHMRGT003

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060MHSRGT001

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060MHSRGT002

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060MHSRGT003

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060PHERGT001

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060PHERGT002

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060PHERGT003

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060PHMRGT001

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY

GHT2V060PHMRGT002

TAURUS HC Series Industry’s Highest Efficiency DC/DC Converter
GALAXY