7100 Series  
Compact Analog Addressable  
Fire Alarm Control Panel  
Description  
The Gamewell-FCI 7100 Series fire alarm control panel is a  
multi processor-based, analog addressable system. The  
control panel is a compact, yet expandable, platform.  
Intended for commercial, industrial and institutional instal-  
lations, the 7100 Series is ideal for life safety and property  
protection fire alarm applications.  
The basic 7100 Series control panel provides one (1) or  
two (2), analog addressable Signaling Line Circuits (SLCs).  
Each SLC supports up to ninety-eight (98) analog address-  
able sensors, as well as up to ninety-nine (99) addressable  
monitor modules and/or control points. With 197 addresses  
available on the 7100-1 and 394 addresses available on  
the 7100-2. The 7100 uses an advanced protocol that  
ensures an almost instant response to events while at the  
same time suppressing nuisance alarms.  
7100 Series  
Features  
Listed per ANSI/UL 864 9th Edition  
120 or 240 VAC (optional) input line voltage  
Front panel programming with day/night sensitivity  
adjustments  
The system may be programmed with either the  
Windows®-based Field Configuration Program (FCP-7100)  
or configured through a comprehensive set of intuitive,  
secure password protected front-panel programming  
options. This important feature allows the system to quickly  
adapt to any future requirements due to changes in occu-  
pancies, building remodels, or other contingencies.  
80-character alpha-numeric display  
One or two Style 4 (Class “B”) signaling line circuits.  
Style 6 (Class “A”) with optional CAOM Module  
Two Style Y (Class “B”) regulated notification appliance  
circuits rated for 1.5 amp. each. Style Z (Class “A”) with  
optional CAOM Module  
The sophisticated circuitry and powerful analog software  
enables the 7100 Series fire alarm control panel to read the  
specific sensitivity level of each sensor and compensate for  
changes due to age, dust accumulation or other environ-  
mental factors. The 7100 incorporates the Gamewell-FCI  
Listed Integrated Sensitivity Testing (LIST) which meets  
NFPA 72 sensitivity testing and maintenance requirements.  
The LIST testing allows substantial savings in both mainte-  
nance and service while eliminating nuisance alarms.  
Suitable for pre-action deluge applications with optional  
MCOM Module  
Periodic trouble reminder  
Individual sensor drift compensation  
Dual-stage maintenance alerts (“dirty” and “very dirty”)  
Multilevel sensor sensitivity adjustments (front panel  
programmable)  
The Model 7100-1D and 2D features an integral Digital  
Alarm Communicator Transmitter (DACT) with all popular  
transmission formats and a 16-digit telephone number  
field. It is 8-digit Carrier Information Code (CIC) compliant  
and also prevents “dialer-runaway” in the event of intermit-  
tent system faults. The 7100-1D and 2D are UL Listed for  
continued on the next page  
An ISO 9000-2000 Company  
SIGNALING  
FM  
MEA  
Approved  
APPROVED  
®
®
®
7165-0694:219 (7100)  
7300-0694:231 (LCD-7100)  
7300-0694:241 (LDM-7100)  
307-99-E  
307-99-E Vol. II  
S1869 3003549  
Microsoft Word is a registered trademark of Microsoft Corporation.  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.  
©2008 by Honeywell International Inc. All rights reserved.  
www.gamewell-fci.com  
9020-0466 Rev. E2 page 1 of 3  
LDM-7100  
Description (Continued)  
Remote Station, Proprietary, and Central Station fire alarm  
The LED Driver Module (LDM-7100) is designed to mount  
in a UL Listed remote annunciator and provides outputs for  
remote panel switches and thirty-three (33), remote LEDs.  
Three (3), LDM-7100 modules may be installed in a single  
annunciator for a total of ninety-nine (99), LEDs per annun-  
ciator. This combination may be repeated up to five times  
for a total of fifteen (15), LDM-7100 panels installed at up to  
five (5), different locations. Maximum distances of up to  
4,000 feet (1,219 m) can be achieved using one pair of  
twisted, non-shielded wire for serial communication and  
using another pair of straight-lay wire for operating voltage.  
(For additional information, refer to the LDM-7100 data  
sheet, Part Number: 9020-0519).  
systems. It allows ample space for wiring and room for bat-  
teries up to 7 A/H capacity.  
Features (Continued)  
Alarm verification per individual sensor  
Positive alarm sequence for sensors or monitor  
modules  
Four levels of system access using six (6), digit pass-  
words with up to five (5), user passwords per Level  
Duplicate and extra address indications  
March time (60 or 120 BPM)/temporal pattern/coded  
fours/California Code/user-defined zone coding  
Cross zoning  
CAOM  
The Class “A” Optional Module (CAOM) allows Style Y and  
Z (Class “B” and “A”) operation for both Notification Appli-  
ance Circuits and allows Style 4 and 6 (Class “B” and “A”)  
for both Signaling Line Circuits. It also provides disconnect  
switches for each signaling line circuit and a common dis-  
connect switch for both notification appliance circuits.  
System configuration programming and 280 event log  
stored in non-volatile memory  
Fan restart with sequential restart delay  
Upload/download of panel configuration between panel  
and FCP-7100 program (password protected feature)  
Up to sixty-four (64), 7100 panels in the E3 Broadband  
network with an optional INI-7100 Module  
MCOM  
The Municipal Connection Option Module (MCOM) pro-  
vides three (3) choices of outputs. It can be configured as a  
Municipal Circuit (City Box) output. It may also be set to  
serve as a Reverse Polarity output with a nominal voltage  
output of 24 VDC at 0.012 amp. maximum alarm and  
supervisory current. The MCOM’s third option provides a  
releasing solenoid output rated at:  
Optional Accessories  
LCD-7100  
The LCD-7100 remote serial display offers an 80-character  
alphanumeric readout for the remote display of all system  
events. It duplicates all the information on the 7100 Series  
panel display and provides key switch protected functions  
such as System Reset, Alarm Acknowledge, Trouble  
Acknowledge, Signal Silence, and Drill Test.  
24 VDC nominal voltage.  
0.005 amp. supervisory current.  
0.710 amp. maximum alarm current.  
2 ohms maximum line resistance.  
LEDs on the LCD-7100 indicate Alarm, Supervisory, Sys-  
tem Trouble, Power Fault, Systems Silenced, NAC#1, and  
NAC#2 Silenced conditions.  
PTRM  
The Printer Transient Module (PTRM) provides RS-232  
Isolator/Transient protection for the 7100’s RS-232 port  
(BSM connector J2). It is used in conjunction with a serial  
printer applied to the RS-232 port for permanent record  
keeping.  
The LCD-7100 can be surface or semi-flush mounted on a  
standard four-gang electrical box. It can be installed up to  
4,000 feet (1,219 m) from the main control panel. The 7100  
Series fire alarm control panel supports up to five (5),  
remote LCD-7100 annunciators using one pair of twisted,  
non-shielded 18 AWG min. wire or serial communication  
and uses another pair of 16 AWG min. for operating volt-  
age.  
INI-7100  
The Intelligent Network Interface Module allows the 7100  
Series fire alarm control panel to become the platform of a  
peer-to-peer, token ring, self-regenerative network com-  
prised of up to sixty-four (64), 7100 panels.  
(For additional information, refer to the LCD-7100 data  
sheet, Part Number: 9020-0486).  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
9020-0466 Rev. E2 page 2 of 3  
www.gamewell-fci.com  
Specifications  
Ordering Information (Continued)  
Optional Modules  
Primary Input Power 120 VAC, 50/60 Hz @ 2.0 amps.  
LCD-7100  
Remote Serial Annunciator, LCD  
or240VAC,50/60Hz@1.0amp.  
4 amps. @ 24 VDC (total)  
Display (80-character)  
Output Power  
Non-resettable Power: 1.0 amp. max.  
1.0 amp. max. from both circuits  
1.0 amp. max.  
Dimensions:  
4.25” H x 8.25” W x 1.90”  
(43 H x 37 W x 7.7 D cm)  
LDM-7100  
Dimensions:  
CAOM  
Remote LED Driver Module  
6” W x 4.50” (15.2 x 11.4 cm)  
Class A Option Combination Module  
with disconnect switches for both  
signaling line circuits and notification  
appliance circuits  
Resettable Power:  
Two (2) Notification  
1.5 amp. each @ 24 VDC  
Appliance Circuits:  
Current:  
7100-1 (One SLC)  
Supervisory  
0.065 amp.  
0.085 amp.  
Alarm  
0.085 amp.  
0.105 amp.  
7100-1D  
MCOM  
Municipal Connection Option Module  
for local energy city box reverse polar-  
ity signaling, or releasing solenoid  
Printer Transient Module  
(One SLC w/DACT)  
7100-2 (Two SLC)  
7100-2D  
(Two SLC w/DACT)  
LCD-7100  
0.065 amp.  
0.085 amp.  
PTRM  
0.085 amp.  
.012 amp.  
.012 amp.  
0.105 amp.  
.023 amp.  
.023 amp.  
(All LEDs lit)  
0.040 amp.  
INI-7100-FO  
Intelligent Network Interface Module,  
Fiber-Optic  
LDM-7100  
INI-7100-UTP  
Intelligent Network Interface Module,  
Unshielded, Twisted-Pair  
INI-7100-UTP,-FO  
Operating  
Temperature:  
Relative Humidity:  
Battery Charger  
Capacity:  
0.040 amp.  
Replacement Parts  
T-7100  
Transformer, 120 VAC input (replace-  
32° - 120° F (0° - 49° C)  
85 % (non-condensing)  
ment)  
T-7100-240  
Transformer, 240 VAC input (replace-  
ment)  
31 A/H (Cabinet accommodates  
12 A/H size batteries)  
BSM-7100-1  
BSM-7100-1D  
Replacement board for 7100-1  
Replacement board for 7100-1D  
Alarm & Trouble  
Relay Contacts:  
Form “C”, 2 amps. @ 24 VDC  
(resistive)  
Ordering Information  
Systems  
Model  
7100-1  
Description  
7100 Addressable System, 1 SLC  
mounted in enclosure  
Dimensions:  
7100-1D  
19 3/8” x 19 3/8” (49 x 49 cm) Enclosure  
7100 Addressable FACP w/DACT,  
1 SLC mounted in enclosure  
19 3/8” x 19 3/8” (49 x 49 cm) Enclosure  
Dimensions:  
Basic Kits  
BK-7100-2  
Basic System Kit, 2 SLC  
(BSM, Keypad Display, Transformer)  
Basic System Kit w/DACT, 2 SLC  
BK-7100-2D  
BK-7100-2-240V Basic System Kit, 2 SLC, 240 VAC  
BK-7100-2D-240V Basic System Kit w/DACT, 2 SLC  
Cabinets  
EN-7100  
CS-7100M  
7100-ENCL-M  
Dimensions:  
Enclosure (replacement)  
Metal Door (replacement)  
7100 Enclosure  
16.9” H x 14.4” W x 3” D l  
(43 H x 37 W x 7.7 D cm)  
NS-7100B  
NS-7100R  
Enclosure, E3 Series Broadband,  
black Enclosure,  
E3 Series Broadband, red  
19 3/8” H x 19 3/8” W x 4” D  
(49 H x 49 W x 10 D cm)  
Dimensions:  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
9020-0466 Rev. E2 page 3 of 3  
www.gamewell-fci.com  

相关型号:

BK-7100-2-240V

Compact Analog Addressable Fire Alarm Control Panel
GAMEWELL-FCI

BK-7100-2D

Compact Analog Addressable Fire Alarm Control Panel
GAMEWELL-FCI

BK-7100-2D-240V

Compact Analog Addressable Fire Alarm Control Panel
GAMEWELL-FCI

BK-80AAAB9B

BATTERY NIMH 1.2V 750MAH AAA
PANASONIC

BK-82

CONTACT BATTERY AAA SIZE
ETC

BK-868

RETAINER 16MM DIAMETER CELL SMD
ETC

BK-869

RETAINER 16MM COIN CELL W/PC PIN
ETC

BK-870

BATTERY RETAINER CR1025
ETC

BK-870-TR

BATTERY RETAINER CR1025 REEL
ETC

BK-874

FEED THRU D CELL CONTACT
ETC

BK-875

POSITIVE D CELL CONTACT
ETC

BK-876

CONTACT BATTERY FOR D CELL
ETC