MB-G6-12-R [GAMEWELL-FCI]

Wheelock MB Series Motor Bells; 会德丰MB系列电机钟声
MB-G6-12-R
型号: MB-G6-12-R
厂家: GAMEWELL-FCI BY HONEYWELL    GAMEWELL-FCI BY HONEYWELL
描述:

Wheelock MB Series Motor Bells
会德丰MB系列电机钟声

电机
文件: 总2页 (文件大小:149K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Features  
Wheelock MB Series  
Motor Bells  
• High sound output with low  
current draw.  
• Low frequency aluminum shells  
for better audibility through walls,  
doors and other structures.  
• 6” and 10” shell sizes in 12 or 24  
VDC models.  
• Integral RFI suppression to  
minimize included noise on the  
NAC circuit.  
Description  
Wheelock’s Series MB Motor Bells  
provide a better engineered motor bell  
for fire and life safety alarm systems.  
The Wheelock Series MB Bells include  
higher dBA, low current draw, built-in  
trimplate for semi-flush mounting, low  
frequency aluminum shells, and low RFI  
noise. The motor for Series MB Bells is  
a durable, high torque permanent  
magnet motor selected for its high  
performance and long life.  
• Mounting options for surface,  
semi-flush, outdoor, and con-  
cealed conduit installation.  
• Built-in trimplate makes semi-  
flush mounting simpler and less  
expensive  
• Polarized for DC supervision of  
NAC circuits.  
Series RSSP Sync/Non-Sync retrofit  
plates are used in conjunction with the  
Series MB Motor Bell when combination  
appliances are required. The Series  
RSSP retrofit plates are available with  
either Multi-Candela or single candela  
strobes and easily mount to a 4” square  
or Wheelock SBL-2 backbox. All Series  
RSSP strobe appliances meet or exceed  
the requirements of NFPA 72 (National  
Fire Alarm Code), ANSI 117.1 (American  
National Standard for Accessible and  
Usable Buildings and Facilities), ADA  
(Americans with Disabilities Act) and UL  
Standard 1971 (Signaling Devices for the  
Hearing Impaired).  
• Operates on filtered or unfiltered  
DC.  
Listings  
Listings and approvals below  
apply to Wheelock MB Series  
Motor Bells. In some cases,  
certain modules may not be  
listed by certain approval agen-  
cies, or listing may be in pro-  
cess. Consult factory for latest  
listing status.  
• UL Listed: file E5946  
• ULC Listed: file CS243  
• FM approved.  
The Series RSSP retrofit plates may be synchronized when installed with the  
Wheelock Series SM, DSM, Sync Modules or a Power Supply with Wheelock’s  
patented sync protocol. Wheelock’s synchronized strobes offer an easy way to  
comply with ADA requirements concerning photo-sensitive epilepsy.  
• MEA approved: file 151-92-E.  
• CSFM approved: files 7135-  
0785:113.  
Engineers Specification  
The alarm appliances shall be Wheelock Series MB vibrating Motor Bells or  
approved equal. They shall be UL Standard 464 Listed for Fire Protective  
Service. Shells shall be aluminum in 6” or 10” diameter. Sound output at 10  
feet shall be 92 dBA. The bells shall incorporate a permanent magnet motor  
and suppression circuitry to minimize RFI. They shall include a built-in  
trimplate for semi-flush mounting to a standard 4” square backbox, or surface  
mounting to Wheelock’s indoor BB backbox or outdoor WBB backbox. For  
bell strobe applications, retrofit plates Wheelock Series RSSP with Multi-  
Candela or Single Candela strobes shall be used. All bell models shall be  
polarized for line supervision and shall have screw terminals for in-out field  
wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or  
12 VDC. Finish on all models shall be red enamel.  
MB Series Motor Bells CS-2236 05/04/04  
Page 1 of 2  
Ordering Information  
NOMINAL  
VOLTAGE  
(VDC)  
AVERAGE CURRENT  
(amps) @ LISTED  
VDC  
MODEL  
STROBE  
INPUT  
MODEL  
SHELL  
INPUT  
NUMBER  
CANDELA  
VOLTAGE  
(VDC)  
12  
NUMBER  
SIZE  
CURRENT  
RSSP-24MCW-FR  
RSSP-241575W-FR  
RSSP-121575W-FR  
24  
24  
12  
15/30/75/110  
15 (75 on axis)  
15 (75 on axis)  
.050/.081/.133/.161  
MB-G6-12-R  
MB-G6-24-R  
MB-G10-12-R 10"  
MB-G10-24-R 10"  
NOTES:  
6"  
6"  
0.060  
0.030  
0.060  
0.030  
0.065  
0.170  
24  
12  
24  
1. Mounting options are: D,E,Z  
2. Average current per actual Wheelock product testing at listed VDC.  
For rated average and peak current across UL regulated voltage range  
for both filtered DC and unfiltered VRMS, see Installation instructions.  
1. Typical dBA at 10 feet is 92, measured in an  
anechoic chamber.  
2.Mounting options are: D,E,J,K,N,R,S,Z  
3. For bells at 12 VDC models are UL rated for 9.0 to  
15.6 VDC and all 24 VDC models for 18.0 to 31.0  
SYNC MODELS/POWER SUPPLY  
AVERAGE  
INPUT  
SM Sync Module is rated for 3.0 amperes @ 24VDC.  
M ODEL  
M EAN  
MOUNTING  
VOLTAGE  
(VDC)  
NUMBER  
CURRENT OPTIONS**  
@ 24 VDC  
DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of  
interconnected DSM modules is twenty (20).  
SM-12/24-R  
DSM-12/24-R  
24  
24  
.028  
.035  
W
W
** Refer to mounting options data sheet.  
Wiring Diagram  
Fig. 1 Bell Models  
Fig. 2 Retrofit Strobe  
AUDIBLE  
STROBE  
+
+
-
-
+
-
FROM  
TO NEXT  
APPLIANCE  
OR EOLR  
PRECEDING  
APPLIANCE OR  
FACP  
-
-
TO NEXT  
FROM  
+
+
APPLIANCE  
OR END-OF-LINE  
}
RESISTOR  
PRECEDING  
APPLIANCE  
OR FACP  
{
FROM  
TO NEXT  
STROBE OR  
EOLR  
(EOLR)  
-
-
PRECEDING  
STROBE OR  
FACP  
+
+
Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed,  
operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at  
least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification,  
application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in  
accordance with all of the latest National Fire Protection Association (NFPA), Underwriters’ Laboratories (UL), National Electrical  
Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other  
applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and  
amendments and the requirements of the local authority having jurisdiction (AHJ).  
WARNING  
PLEASE READ THESE SPECIFICATIONSANDASSOCIATED INSTALLATION INSTRUCTIONS  
CAREFULLY BEFORE USING, SPECIFYING ORAPPLYING THIS PRODUCT. FAILURE TO COM-  
PLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN  
The Gamewell Company  
12 Clintonville Road  
IMPROPERAPPLICATION, INSTALLATIONAND/OR OPERATION OF THESE PRODUCTS INAN  
EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS  
INJURY OR DEATH TO YOUAND/OR OTHERS.  
Northford, CT 06472-1610  
Phone: 203-484-7161  
Fax: 203-484-7118  
Specifications and wiring information are provided for information only and are believed  
to be accurate. Gamewell assumes no responsibility for their use.  
Data and design are subject to change without notice. Installation and wiring  
instructions shipped with the product shall always be used for actual installation. For  
more information, contact Gamewell.  
www.gamewell.com  
A Honeywell Company  
© 2004 Gamewell  
Page 2 of 2  
MB Series Motor Bells CS-2236 05/04/04  

相关型号:

MB-G6-24-R

Wheelock MB Series Motor Bells
GAMEWELL-FCI

MB-HK

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD

MB-HK95-02XA5

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD

MB-HK95-03GA5

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD

MB-HK95-03XA5

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD

MB-HK95-04GA5

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD

MB-HK96-02XA5

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD

MB-HK96-03GA5

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD

MB-HK96-03XA5

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD

MB-HK96-04GA5

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD

MB-LK

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD

MB-LKG4-03GA5

CABLES - CAVI, No toxic, low smoke, halogen free
SHIELD