100ACMEB Series  
100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated  
AC-DC Converter  
100 Watt  
Universal input: 90~264VAC  
Regulated output, low ripple  
and noise  
Over voltage protection (OVP)  
Meets EN60950, UL60950  
UL / IEC / EN 60601 3.1  
Edition & UL / IEC / EN 60950  
AM2 Safety Approvals  
Meets EN60601-1, ANSI/  
AAMI ES60601-1 standards  
(2 x MOOP)  
The 100ACMEB series is a compact size power converter offered by  
GAPTEC. It features universal input voltage, taking both DC and AC  
input voltage, low power consumption, high efficiency, high reliability,  
safer isolation. It offers good EMC performance, meets IEC/EN61000-4,  
CISPR22/EN55022, UL60950 and EN60950 standards, and is widely used  
in medical instrumentation and critical applications in commercial and  
industrial electronic equipment.  
High efficiency up to 90%  
Short circuit protection (SCP)  
Output power protection (OPP)  
With PFC Function >0.9  
<0.3W No Load Input Power  
(pending)  
Approval  
Model  
Power  
[W]  
Output voltage  
[V]  
Output current  
[mA, max]  
Capacitive Load  
[µF, max]  
Efficiency  
[@230VAC, %, typ]  
UL/CE  
UL/CE  
UL/CE  
100ACMEB_12S4  
100ACMEB_24S4  
100ACMEB_48S4  
100  
100  
100  
12  
24  
48  
6666  
4167  
2083  
3000  
1500  
500  
90  
90  
90  
Input specifications  
Output specifications  
Input voltage range  
90-264 VAC  
Item  
Test conditions  
Min Typ  
2
Max  
160  
Units  
%
“ N ” to DC “ + “ ; “L ” to DC “ - “  
Output voltage  
accuracy  
Full load  
Input frequency  
Input current  
47~63Hz  
115VAC  
• 2A (max)  
230VAC  
• 1A (max)  
Line regulation  
Load regulation  
Ripple & noise*  
1
1
%
10% to 100% load  
%
Inrush current  
(<2ms)  
115VAC  
• 45A (typ)  
230VAC  
• 90A (typ)  
• 100ACMEB_12S4  
• Others  
mV  
1% of Vout  
Leakage current  
< 0.1mA/264VAC (touch current)  
>0.97 (115 VAC) / PF>0.9 (230 VAC)  
Hold-up time  
@90% Vout/115VAC  
10  
ms  
Power factor  
(at full load)  
* Measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.  
Protection specifications  
Example:  
100ACMEB_05S4  
Short circuit  
protection  
Protection type:  
Auto recovery, hiccup mode  
100 = 100Watt; AC = AC-DC; MEB = series; 5Vout; S = Single Output;  
4 = 4kVAC  
Over-voltage  
protection  
Protection type:  
Auto recovery, hiccup mode  
Over-power  
protection  
Protection type:  
Note:  
Auto recovery, hiccup mode  
1. This product is not designed for use in critical life support systems, equipment  
used in hazardous environment, nuclear control systems or other such  
applications which necessitate specific safety and regulatory standards other  
the ones listed in this datasheet.  
Over-temperature  
protection  
Protection type:  
Latch off  
2. All specifications valid at 230VAC input voltage, full load and +25°C after  
warm-up time unless otherwise stated.  
Page 1 of 3  
100ACMEB – Rev. 2017-1.0  
Specifications subject to change without notice.  
GAPTEC-Electronic GmbH & Co. KG  
sales@gaptec-electronic.com – www.gaptec-electronic.com  
100ACMEB Series  
100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated  
Common specifications  
Operating temperature range  
Storage temperature range  
Case temperature range  
Humidity (non-condensing)  
Cooling  
-30°C ~ +70°C (with derating)  
-30°C ~ +85°C  
Under 115VAC 73°C, others 80°C  
95% MAX  
Free air convection  
Temperature coefficient  
I/O-isolation voltage  
0.05%/°C  
Input-Output: 4000VAC or 5656VDC  
Input-FG:  
Output-FG:  
2000VAC or 2828VDC  
1500VAC or 2121VDC  
Altitude during operation  
Atmospheric pressure  
EMC / EMI / Conducted and radiated EMI*  
EMC / EMS / ESD  
5000m  
70kPa to 106kPa  
EN55032 Conducted & Radiated Class B  
IEC/EN 61000-4-2  
IEC/EN 61000-4-3  
IEC/EN 61000-4-4  
IEC/EN 61000-4-5  
IEC/EN 61000-4-6  
IEC/EN 61000-4-8  
IEC/EN 61000-4-11  
EN61000-4-11  
Contact 4KV / Air 8KV  
perf. Criteria B  
perf. Criteria A  
perf. Criteria B  
perf. Criteria B  
perf. Criteria A  
perf. Criteria A  
perf. Criteria B  
EMC / EMS / Radiated Immunity  
EMC / EMS / Fast Transient  
EMC / EMS / Surge  
EMC / EMS / Conducted immunity  
EMC / EMS / PFMF  
EMC / EMS / Dips  
10V/m  
2kV  
1KV  
10Vr.m.s  
30A/m  
30% / 10ms  
>95% 5000ms  
EMC / EMS / Interruption  
Safety standards  
IEC60950, EN60950, UL60950  
Safety approvals  
UL / IEC / EN 60601 3.1rd Edition & UL / IEC / EN 60950 AM2  
UL94V-0  
Case material  
MTBF  
>250,000 h @ 25°C (MIL-HDBK-217F, Notice 1)  
10~500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes.  
83.9 x 58.5 x 35.0 mm  
Vibration  
Package  
Weight  
253 g  
* Please secure the power supply unit to your metal case by using the four screw holes in the corners for either Class I or Class II equipment.  
Typical characteristics  
Derating graphs  
Power derating  
Page 2 of 3  
GAPTEC-Electronic GmbH & Co. KG  
sales@gaptec-electronic.com – www.gaptec-electronic.com  
100ACMEB – Rev. 2017-1.0  
Specifications subject to change without notice.  
100ACMEB Series  
100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated  
Block diagram  
Mechanical dimensions  
PIN  
1
ø
Single  
PE  
1.2 0.1%mm  
1.2 0.1%mm  
1.2 0.1%mm  
1.2 0.1%mm  
2
AC IN (L)  
AC IN (N)  
ON / OFF  
3
4
(Provide +5Vdc Controlled)  
5
6
7
1.8 0.1%mm  
1.8 0.1%mm  
1.8 0.1%mm  
+DC OUT  
-DC OUT  
Trim  
Note:  
Please reserve the pin 4 hole on PCB.  
If the remote on/off function is not required, please  
connect the pin 4 circuit layout with pin6, or keep pin 4  
floating.  
Note:  
Unit: mm[inch]  
General tolerances: 0.50mm [ 0.020inch]  
Page 3 of 3  
GAPTEC-Electronic GmbH & Co. KG  
sales@gaptec-electronic.com – www.gaptec-electronic.com  
100ACMEB – Rev. 2017-1.0  
Specifications subject to change without notice.  

相关型号:

100ACMEB_12S4

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACMEB_24S4

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACMEB_48S4

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACP

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACPM

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACPM_05SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACPM_12SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACPM_24SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACPM_48SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACP_12SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACP_24SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACP_36SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC