120ACDR_SC Series
120W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
Industrial DIN Rail Power Supply
AC-DC Converter
120 Watt
High efficiency up to 92%
Universal AC input range
(85~264VAC)
Over voltage protection (OVP)
Over load protection (OLP)
Short circuit protection (SCP)
Over temperature prot. (OTP)
Wide operating ambient
temperature (-25°C~70°C)
150% (180W) peak load
capacity
The 120ACDR_SC series features standard rail mounting, energy efficiency
and is highly cost-effective. The series offers stability and high noise
immunity especially for industrial control equipment, machinery and
other demanding environments for industrial equipment. This converter
offers a compact and light weight design with and standard rail installation
(32mm). Furthermore this series offers Easy Fuse Tripping due and a
built-in DC OK relay contact. The converter can be installed on TS-35/7.5
or TS-35/15.
Support 1+1 or N+1
redundant system
Built-in current
sharing function
Built-in current limiting circuit
100% full load burn-in test
UL-60950-1 (E347551)
Common specifications
Short circut protection:
Temperature rise at full load:
Cooling:
Input specifications
Long-term mode, automatic recovery
40ꢀC MAX
Input voltage range
Input frequency
Power factor
85~264VAC, 127-360VDC
47~63Hz
100VAC
• 0.99 (typ)
230VAC
• 0.95 (typ)
Free air convection
-25ꢀC~+70ꢀC
Operation temperature range:
Storage temperature range:
Storage humidity range:
Temperature coefficient:
MTBF (using MIL-HDBK-217F):
Safety standards:
AC current
100VAC
• 1.5A (max)
230VAC
• 0.65A (max)
-40ꢀC ~+85ꢀC
< 95%
Inrush current
Leakage current
Cold start
100VAC
• 30A (typ)
230VAC
• 60A (typ)
0.03%/ꢀC MAX
Input—output: <0.25mA
Input—PG: <3.5mA
+25ꢀC >300,000 hours
meet UL508, UL60950, EN60950
150% of rated current
support
Power boost:
Output specifications
Parallel function:
Item
Test conditions
Full load
Min Typ
Max
3
Units
DC-OK:
V On: when output voltage is up to 90%
of rated output voltage
V Off: when output voltage is down to
80% of rated output voltage
Output voltage
accuracy
%
Voltage adjustment • 12V: 12V~14V
range
• 24V: 24~28V
• 48V: 48~56V
DC-OK relay contact rating:
Case material:
Max 30V/1A or 60V/0.3A or 30Vac/0.3A
resistive load
Line regulation
Vin= min. to max. at
full load
0.5
1
%
%
Heat-resistant Plastic (UL94-V0) and
metal
Load regulation
Ripple + Noise
Set-up time
0% to 100% load
Dimensions:
Weight:
124*119*32mm
643g
see model specifications table
• @230VAC
• @100VAC
250
100
ms
ms
Isolation specifications
Hold-up time
@230VAC, full load
20
ms
%
Item
Test condition
Min
Typ
Max
Units
VAC
Overshoot and
undershoot
5
Withstand voltage*
• Primary-Sec. ≤10mA
• Primary-PG ≤10mA
• Secondary-PG ≤10mA
3000
2500
500
Switching frequency
100
KHz
Isolation resistance
100
MΩ
Protection specifications
* Input-Output, tested for 1 minute, 500VDC and leakage current less than 1mA
Over-load
protection
110%~150% of rated current, Constant current limiting for
some time(150% of rated current, last 3S) then PS
stop working for 7S,after 7S, if the load <=rated current,
PS will work normally, auto recovery
Example:
120ACDR_24SC
Over-voltage
protection
• 12V: 15~18V, hiccup mode, auto recovery
• 24V: 28.8~33V, hiccup mode, auto recovery
• 28V: 58~63V, hiccup mode, auto recovery
120 = 120 Watts
AC = AC/DC
DR = Din Rail
24 = Vout
S = Single Output
C = PFC (Power Factor Correction)
Over-temperature
protection
100 5ꢀC, detect on heat sink of power transistor; shut
down O/P, auto recovery after temperature goes down.
Note:
1. All parameters NOT specially mentioned are measured at rated input, rated load
and 25ꢀC of ambient temperature.
Page 1 of 6
120ACDR_SC – Rev. 2020-1.3
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com
120ACDR_SC Series
120W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
Industrial DIN Rail Power Supply
EMC specifications
EMC / Emission
Compliance to EN55022, EN55024, FCC PART 15 Class B
Compliance to EN61000-3-2, CLASS A
EMC / Harmonic current
EMC / Immunity
Compliance to EN61000-4-2, -3, -4, -5, -6, -8, -11; heavy industry level
perf. Criteria B
The power supply is considered as a component which will be installed into a final equipment.
The final equipment must be re-confirmed that it still meets EMC directives.
Approval
Model
Power
[W]
Output
Rated Current
[A]
Current Range
[A]
Ripple&Noise* [mV, max]
Efficiency
[%, typ]
[Vo, VDC]
0~70ꢀC
-25ꢀC
200
240
UL (pending)
UL (pending)
UL (pending)
120ACDR_12SC
120ACDR_24SC
120ACDR_48SC
120
120
120
12
24
48
10
5
0~10
0~5
100
89.5
91
120
2.5
0~2.5
240
240
92
* Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
Mechanical dimensions
120ACDR_SC
AC terminal blocks installation information
AC/DC terminal
Type
Terminal No.
Function
Wire specs
Rec. torque
1Nm
Screw terminal blocks
0.5-6mm2
0.5-4mm2
1
2
3
L
N
Solid wire
20~10AWG
Strand wire
Wire Spec
PG
AWG20-10 (PG wire >18AWG)
2.8mm
Max wire diameter
DC terminal blocks installation information
Recommended stripping length 7mm
Terminal No.
4&5
Function
Wire specs
Rec. torque
1Nm
Screwdriver
3.5mm Straight or Cross Screwdriver
1NM
DC OK Relay
contact
Recommended torque
20~10AWG
6
7
-V
+V
Page 2 of 6
120ACDR_SC – Rev. 2020-1.3
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com
120ACDR_SC Series
120W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
Industrial DIN Rail Power Supply
Typical characteristics
Output current vs. ambient temperature – 120ACDR_12SC
Output current vs. ambient temperature – 120ACDR_24SC
Ambient temperature (ꢀC)
Ambient temperature (ꢀC)
Output current vs. ambient temperature – 120ACDR_48SC
Ambient temperature (ꢀC)
short time working, 3s.
continuous working
Functional block diagram
Functional diagram
Page 3 of 6
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com
120ACDR_SC – Rev. 2020-1.3
Specifications subject to change without notice.
120ACDR_SC Series
120W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
Industrial DIN Rail Power Supply
Mounting method instruction
A1 is recommended output current.
A2 is the allowed max output current (PSU lifetime is around half of A1).
Below curves are tested under 230Vac (179~264Vac), when 110Vac input
(85~175Vac), all derating points drop 10ꢀC.
120ACDR_12SC
Mounting A
Mounting B
Mounting C
Mounting D
Mounting E
Page 4 of 6
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com
120ACDR_SC – Rev. 2020-1.3
Specifications subject to change without notice.
120ACDR_SC Series
120W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
Industrial DIN Rail Power Supply
Mounting method instruction
120ACDR_24SC
Mounting A
Mounting B
Mounting C
Mounting D
Mounting E
Page 5 of 6
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com
120ACDR_SC – Rev. 2020-1.3
Specifications subject to change without notice.
120ACDR_SC Series
120W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
Industrial DIN Rail Power Supply
Mounting method instruction
120ACDR_48SC
Mounting A
Mounting B
Mounting C
Mounting D
Mounting E
Page 6 of 6
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com
120ACDR_SC – Rev. 2020-1.3
Specifications subject to change without notice.
相关型号:
120ACDR_SC
120W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Industrial DIN Rail Power Supply
GAPTEC
©2020 ICPDF网 联系我们和版权申明