LME78_09-1.0 [GAPTEC]

Wide Input Non-Isolated & Regulated, Single Positive/Negative Output;
LME78_09-1.0
型号: LME78_09-1.0
厂家: GAPTEC    GAPTEC
描述:

Wide Input Non-Isolated & Regulated, Single Positive/Negative Output

文件: 总4页 (文件大小:3060K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LME78_1.0 series  
Wide Input Non-Isolated & Regulated, Single Positive/Negative Output  
Switching Regulator  
High efficiency up to 96%  
Operating temperature range:  
-40°C ~ +85°C  
Short circuit protection (SCP)  
No-load input current as low  
as 0.3mA  
3PIN SIP package  
The LME78_1.0 are high efficiency switching regulators and ideal  
substitutes of LM78xx series three-terminal linear regulators. The  
product is featured with high efficiency, low loss, short circuit protection  
and no heat sink requirement. They are widely used in industrial control,  
instrumentation, and electric power applications.  
Non isolated, no need for  
heatsink  
UL94V-0 package material  
IEC62368, UL62368, EN62368  
approved  
UL-62368-1 (E347551)  
Common specifications  
Short circuit protection:  
No-load input current:  
Temperature rise at full load:  
Cooling:  
Output specifications  
Hiccup, automatic recovery  
2mA TYP, 5mA MAX  
25°C MAX, 15°C TYP  
Item  
Test conditions  
Min  
Typ  
Max  
Units  
Voltage accuracy  
Full load, input voltage  
range  
• LME78_03-1.0  
• Others  
2
1.5  
4
3
%
%
Free air convection  
Line regulation  
Load regulation  
Full load, input voltage  
range  
0.2  
0.4  
%
Operation temperature range:  
-40°C~+85°C  
(see temperature derating curve)  
10% to 100% load  
• positive output  
• negative output  
Storage temperature range:  
Pin welding resistance temperature:  
Operating case temperature:  
Storage humidity range:  
Package material:  
-55°C ~+125°C  
0.4  
0.4  
0.6  
0.8  
%
%
260°C MAX, 1.5mm from case for 10 sec  
100°C  
Ripple + Noise*  
20MHz bandwidth,  
nominal input, 20%  
-100% load  
25  
75  
mVp-p  
< 95%RH  
Plastic [UL94-V0]  
2000 K hours  
1.9g  
Switching frequency  
520  
KHz  
MTBF (MIL-HDBK-217F @25°C):  
Weight:  
Temperature Drift  
Coefficient  
0.03 %/°C  
Transient response  
deviation  
Nominal input,  
60  
200  
mV  
ms  
25%-50%-25%, 50%-75%-  
50% load step change  
Input specifications  
Item  
Test conditions  
Min  
Typ  
Max  
Units  
Transient recovery  
time  
Nominal input,  
25%-50%-25%, 50%-75%-  
50% load step change  
1
No-load input  
current  
• positive output  
• negative output  
0.3  
1
1
4
mA  
mA  
Reverse polarity  
input  
Forbidden  
* Test ripple and noise by “parallel cable” method.  
With the load lower than 20%, the maximum ripple and noise of 3.3V/5V output  
products will be 100mVp-p, 9V/12V/15V output products will be 2%Vo.  
Input Filter  
Capacitor Filter  
* Test ripple and noise by “parallel cable” method.  
EMC specifications  
Example:  
EMI  
EMI  
EMS  
EMS  
EMS  
CE  
CISPR32/EN55032  
CISPR32/EN55032  
IEC/EN61000-4-2  
IEC/EN61000-4-3  
IEC/EN61000-4-4  
CLASS B  
LME78_05-1.0  
(see EMC rec. circuit 2 )  
LME78 = Series; 05 = 5Vout; 1.0 = 1.0A  
RE  
CLASS B  
(see EMC rec. circuit 2 )  
Note:  
ESD  
RS  
Contact 4KV  
perf. Criteria A  
1. The max. capacitive load should be tested within the input voltage range and  
under full load conditions;  
10V/m  
perf. Criteria A  
2. Without any special statement, all indexes are only specific to positive output  
application;  
3. Unless otherwise specified, data in this datasheet should be tested under the  
conditions of Ta = 25°C, humidity <75% when inputting nominal voltage and  
outputting rated load;  
EFT  
1KV  
perf. Criteria A  
(see EMC rec. circuit 1 )  
4. All index testing methods in this datasheet are based on our Company’s  
corporate standards;  
EMS  
EMS  
Surge  
CS  
IEC/EN61000-4-5  
IEC/EN61000-4-6  
line to line 1KV  
perf. Criteria A  
5. The performance indexes of the product models listed in this manual are as  
above, but some indexes of non-standard model products will exceed the  
above-mentioned requirements, and please directly contact with our technician  
for specific information;  
(see EMC rec. circuit 1 )  
3Vr.m.s  
perf. Criteria A  
6. Specifications subject to change without prior notice.  
Page 1 of 4  
LME78_1.0 – Rev. 2020-1.1  
Specifications subject to change without notice.  
GAPTEC-Electronic GmbH & Co. KG  
sales@gaptec-electronic.com – www.gaptec-electronic.com  
LME78_1.0 series  
Wide Input Non-Isolated & Regulated, Single Positive/Negative Output  
Part Number  
Input Voltage [VDC]  
Nominal (Range)  
Output Voltage  
[VDC]  
Output Current  
[mA]  
Capacitive load  
[µF, max.]  
Efficiency  
[%, min/max Vin]  
LME78_03-1.0  
LME78_05-1.0  
24 (6-36)  
3.3  
1000  
680  
90/80  
24 (8-36)  
12 (8-27)  
5
-5  
1000  
-500  
680  
330  
93/95  
85/81  
LME78_09-1.0  
LME78_12-1.0  
24 (13-36)  
9
1000  
680  
94/89  
24 (16-36)  
12 (8-20)  
12  
-12  
1000  
-300  
680  
330  
95/92  
88/87  
LME78_15-1.0  
24 (20-36)  
12 (8-18)  
15  
-15  
1000  
-300  
680  
330  
96/93  
87/88  
Note: For input voltage higher than 30 VDC, a 22μF/50V input capacitor is required.  
Typical characteristics  
Efficiency  
LME78_05-1.0  
LME78_05-1.0  
Page 2 of 4  
LME78_1.0 – Rev. 2020-1.1  
Specifications subject to change without notice.  
GAPTEC-Electronic GmbH & Co. KG  
sales@gaptec-electronic.com – www.gaptec-electronic.com  
LME78_1.0 series  
Wide Input Non-Isolated & Regulated, Single Positive/Negative Output  
Typical application circuit  
Note:  
1. C1 and C2 (C3 and C4) are required and should be connected close to the pin terminal of the module.  
2. The capacitance of C1 and C2 (C3 and C4) refer to Sheet 1.  
3. To reduce the output ripple furtherly, C2 and C4 can be increased properly if required, tantalum  
capacitor and aluminum electrolytic capacitor of low ESR may also suffice.  
4. When the products used as the circuit like figure 3, an inductor named as LDM up to 10μH is  
recommended in the circuit to reduce the mutual interference.  
5. Cannot be used in parallel to enlarge the power for output and hot swap.  
EMC solution recommended circuit  
positive output  
negative output  
Note:  
Part ① in the Fig. 4 is for EMS test, part ② is for EMI filtering; parts ① and ② can be added  
based on actual requirement.  
Page 3 of 4  
LME78_1.0 – Rev. 2020-1.1  
Specifications subject to change without notice.  
GAPTEC-Electronic GmbH & Co. KG  
sales@gaptec-electronic.com – www.gaptec-electronic.com  
LME78_1.0 series  
Wide Input Non-Isolated & Regulated, Single Positive/Negative Output  
Mechanical dimensions  
Page 4 of 4  
LME78_1.0 – Rev. 2020-1.1  
Specifications subject to change without notice.  
GAPTEC-Electronic GmbH & Co. KG  
sales@gaptec-electronic.com – www.gaptec-electronic.com  

相关型号:

LME78_09-2.0

Wide Input Non-Isolated & Regulated, Single Output
GAPTEC

LME78_1.0

Wide Input Non-Isolated & Regulated, Single Positive/Negative Output
GAPTEC

LME78_1.2-2.0

Wide Input Non-Isolated & Regulated, Single Output
GAPTEC

LME78_1.5-2.0

Wide Input Non-Isolated & Regulated, Single Output
GAPTEC

LME78_1.8-2.0

Wide Input Non-Isolated & Regulated, Single Output
GAPTEC

LME78_12-1.0

Wide Input Non-Isolated & Regulated, Single Positive/Negative Output
GAPTEC

LME78_12-2.0

Wide Input Non-Isolated & Regulated, Single Output
GAPTEC

LME78_15-1.0

Wide Input Non-Isolated & Regulated, Single Positive/Negative Output
GAPTEC

LME78_15-2.0

Wide Input Non-Isolated & Regulated, Single Output
GAPTEC

LME78_2.0

Wide Input Non-Isolated & Regulated, Single Output
GAPTEC

LME78_2.5-2.0

Wide Input Non-Isolated & Regulated, Single Output
GAPTEC

LME78_6.5-2.0

Wide Input Non-Isolated & Regulated, Single Output
GAPTEC