C2015A.12.19 [GENERAL]
Wire And Cable, 1 Conductor(s), 24AWG, 300V, Flexible Cord And Fixture Wire,;型号: | C2015A.12.19 |
厂家: | GENERAL CABLE TECHNOLOGIES CORPORATION |
描述: | Wire And Cable, 1 Conductor(s), 24AWG, 300V, Flexible Cord And Fixture Wire, 电气电子设备内部接线 连接器 连接器支架 |
文件: | 总259页 (文件大小:6449K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
What’s New?
E X PA N D E D C O M P E T I T I V E O F F E R I N G S
Cross-Reference & Online Spec Sheets
We have expanded our Carol® Brand Electronics offering and now have more
competitive crosses than anyone. Many of these cables are in stock and ready for
immediate shipment from one of our stocking distributors. For questions on any
of the Carol Electronics cables, detailed spec sheets are now available online at
www.generalcable.com/Products/Electronics/Product Specification Sheets.
L O O K I N G F O R P L E N U M C A B L E S ?
The Carol® Electronics Catalog has been revamped, with Plenum Cables now
being featured in the Communications & Control Multi-Conductor and Multi-Paired
sections. If you’re still not sure what you’re looking for, please contact our Customer
Service associates at 866.295.5896 today!
A L A R M & S E C U R I T Y S O L U T I O N S
General Cable has increased the information in its Alarm & Security Solutions
Guide, with the addition of Sheer Wire™ Cables for Lighting Control & Touch
Panel Systems, Bundled Composite Access Control Cables, Command® Series
Home Entertainment Cables and our line of Carol® Brand Helix/Hi-Temp® Data
Communications Cables. To view the updated guide, see pages 114-116 in
the catalog.
S H E E R W I R E ™ P R O D U C T S
Carol® Brand has added the Sheer Wire™ line of cable for Lighting Control & Touch
Panel Systems to its already expansive electronics offering. For more information,
see page A2 or call 866-295-5896 today for your FREE Sheer Wire catalog.
A R M O R E D E L E C T R O N I C S P R O D U C T S
Carol® Brand Electronics products are now offered with an interlock armored
option, which provides outstanding mechanical protection and is flexible for easy
installation, potentially saving time and money. For complete product information,
go to pages 179-180.
A1
Carol® Brand Alarm & Security Solutions
Call today for your
FREE COMPLETE
SHEER WIRE™
CATALOG
Sheer Wire™ Lighting Control and Touch Panel Systems
Cable
Solution
Description
1.866.295.5896
1618SVA1
1822AXL0
1822CCD8
1822CCT8
1822CDC8
1822CRT8
1822KYP1
182LUTDS
184LUTDS
222LUTDS
164LTCH0
224SLTCH
18/4 16/30 BC 20 AWG 10/30 + 16/1 PR 26/30 BC (UL) CL3R
22/1PR 7/30 + 18/2 7/26 (UL) CL3R FT-4
Touch Panel Composite: 1 Control Element + 2 5e Elements
Touch Panel Composite: 1 Control Element + 2 5e Elements + 2 RG 6
22C 5E: (1)I18/22CRT-89/04, (1)I181VQ6-09, I181VQ6-00, (2) Cat 5e
Comp 4C 2E: 22/1PR 7/30 BC 24 AWG 7/32 TC Drain + 1/2C 7/26 BC (UL) CL3R
Comp 4C 2E: 18/2C 16/30 BC + 22/1PR 7/30 BC Shielded
18/2 7/26 BC PVC NYLON (UL) TC for Lutron Dimmer & Switch
18/4 7/26 BC PVC Nylon O/A AM SHLD 20 AWG 7/36 TC Drain PVC
22/2 7/30 BC PVC O/A AM SHLD 24 AWG 7/32 TC Drain PVC
16/4 65/34 BC .012" PVC Lite Touch
Applications:
Lighting Controls
22/4 7/30 BC .015 PVC, O/A AM SHLD, 24 7/32 TC Drain/A 0.35 PVC Lite Touch
Window Controls
Audio Level Controls
Video Controls
EF24C0021000 24/2 Conductor Shielded Low Cap Type CMP
Computer/Internet Controls
A2
Product Section Locator
Section
PageS
1 Hꢀꢀk-Up Wꢁrꢂ
1-7
2 cꢀmmuꢃꢁꢄꢅꢆꢁꢀꢃ & cꢀꢃꢆrꢀl cꢅblꢂ, Mulꢆꢁ-cꢀꢃduꢄꢆꢀr
3 cꢀmmuꢃꢁꢄꢅꢆꢁꢀꢃ & cꢀꢃꢆrꢀl cꢅblꢂ, Mulꢆꢁ-Pꢅꢁrꢂd
4 cꢀmpuꢆꢂr cꢅblꢂ
8-41
42-66
67-84
5 cꢀꢅxꢁꢅl cꢅblꢂ
85-112
113-129
130-145
146-177
178-185
186-247
6 Fꢁrꢂ alꢅrm/Lꢁfꢂ Sꢅfꢂꢆy cꢅblꢂ
7 Sꢀuꢃd, alꢅrm & Sꢂꢄurꢁꢆy cꢅblꢂ
8 audꢁꢀ/Vꢁdꢂꢀ & Hꢀmꢂ eꢃꢆꢂrꢆꢅꢁꢃmꢂꢃꢆ cꢅblꢂ
9 Spꢂꢄꢁꢅlꢆy cꢅblꢂ
10 tꢂꢄhꢃꢁꢄꢅl iꢃfꢀrmꢅꢆꢁꢀꢃ
tꢅblꢂ ꢀf cꢀꢃꢆꢂꢃꢆs
Section
PageS
1
Hook-Up Wire
1-7
UL 1007, UL 1569, CSA TR-64................................................................................................ 2
UL 1015, CSA TEW.................................................................................................................. 3
MIL-W-76B............................................................................................................................... 4
UL Types MTW, TFF, AWM & CSA TEW .................................................................................. 5
Heavy Wall UL Types MTW, AWM & NEC Type THW.............................................................. 6
Rubber/PVC/Polyethylene........................................................................................................ 7
2
Communication & Control Cable, Multi-Conductor
8-41
Multi-Conductor, Unshielded ..............................................................................................9-17
Multi-Conductor, Unshielded (CSA) ..................................................................................18-20
Multi-Conductor, Rubber, Unshielded.................................................................................... 21
Power-Limited Tray Cable, Unshielded.................................................................................. 22
Multi-Conductor, Foil Shield..............................................................................................23-28
Multi-Conductor, Foil Shield (CSA)....................................................................................29-31
Power-Limited Tray Cable, Foil Shield ................................................................................... 32
Multi-Conductor, Spiral Shield ............................................................................................... 33
Multi-Conductor, Braid Shield...........................................................................................34-37
Multi-Conductor, Foil/Braid Shield......................................................................................... 38
Multi-Conductor, Foil & TC Braid Shield................................................................................ 39
Multi-Conductor, Rubber, Braid Shield .................................................................................. 40
Multi-Conductor, Carolprene®, Braid Shield .......................................................................... 41
3
Communication & Control Cable, Multi-Paired
42-66
Multi-Paired, Unshielded...................................................................................................43-45
Multi-Paired, Foil Shield ....................................................................................................46-52
Multi-Paired, Foil Shield (CSA)..........................................................................................53-54
Multi-Paired, Foil Shield, Mid-Cap......................................................................................... 55
Multi-Paired, Foil Shield, Lo-Cap® ......................................................................................... 56
Multi-Paired, Overall Foil & TC Braid Shield, Lo-Cap® .......................................................... 57
Multi-Paired, Individually Shielded......................................................................................... 58
Multi-Paired, Individually Shielded (CSA)............................................................................... 59
Multi-Paired, Individually Shielded, Overall Shield................................................................. 60
Multi-Paired, Individually Foil Shielded .............................................................................61-64
Power-Limited Tray Cable, Individually Shielded................................................................... 65
Power-Limited Tray Cable, Foil Shield or Foil/Braid Shield ................................................... 66
tꢅblꢂ ꢀf cꢀꢃꢆꢂꢃꢆs
Section
PageS
4
Computer Cable
67-84
Multi-Conductor, Foil Shield..............................................................................................68-69
Multi-Conductor, Foil/Braid Shield....................................................................................70-71
Multi-Conductor, Foil/Braid Shield, Lo-Cap® ......................................................................... 72
Multi-Paired, Foil Shield ......................................................................................................... 73
Multi-Paired, Foil Shield, Lo-Cap® ......................................................................................... 74
Multi-Paired, Foil/Braid Shield................................................................................................ 75
Multi-Paired, Foil/Braid Shield, Lo-Cap®...........................................................................76-79
Multi-Paired, Individually Foil Shielded .............................................................................80-82
Multi-Paired, Individually Foil Shielded, Lo-Cap® .................................................................. 83
Multi-Paired, Individually Foil/Braid Shielded, Lo-Cap®......................................................... 84
5
Coaxial Cable
85-112
Coaxial Solutions Guide..................................................................................................86-87
RG 6/U Type......................................................................................................................88-93
RG 8/U Type......................................................................................................................94-95
RG 11/U Type....................................................................................................................96-99
RG 58/U Type....................................................................................................................... 100
RG 59/U Type................................................................................................................101-108
RG 62/U Type....................................................................................................................... 109
RG 174/U Type..................................................................................................................... 110
RG 213/U Type..................................................................................................................... 111
Twinaxial Cables................................................................................................................... 112
6
Fire Alarm/Life Safety Cable
113-129
Alarm & Security Solutions Guide..............................................................................114-116
Multi-Conductor, Unshielded, Non-Plenum ......................................................................... 117
Multi-Conductor, Unshielded, Non-Plenum (CSA)............................................................... 118
Multi-Conductor, Shielded, Non-Plenum ............................................................................. 119
Multi-Conductor, Shielded, Non-Plenum (CSA)................................................................... 120
Multi-Conductor, Unshielded, Plenum ..........................................................................121-122
Multi-Conductor, Shielded, Plenum ..............................................................................123-124
Mid-Capacitance, Unshielded, Non-Plenum ....................................................................... 125
Mid-Capacitance, Shielded, Non-Plenum............................................................................ 126
Mid-Capacitance, Unshielded, Plenum................................................................................ 127
Mid-Capacitance, Shielded, Plenum.................................................................................... 128
Multi-Paired, Unshielded, Non-Plenum (CSA) ..................................................................... 129
tꢅblꢂ ꢀf cꢀꢃꢆꢂꢃꢆs
Section
PageS
7
Sound, Alarm & Security Cable
130-145
Composite Access Control Cable..................................................................................... 131
Composite Access Control Cable, Plenum.......................................................................... 132
Composite Access Control Cable, Riser.............................................................................. 133
Multi-Conductor, Unshielded, Riser ..................................................................................... 134
Multi-Conductor, Shielded, Riser ......................................................................................... 135
Multi-Conductor, Unshielded, Plenum ................................................................................. 136
Multi-Conductor, Shielded, Plenum ..................................................................................... 137
Telephone Station/Intercom & Speaker/Burglar Alarm ....................................................... 138
Antenna Rotor ...................................................................................................................... 139
Low-Voltage Sprinkler Wire.................................................................................................. 140
Thermostat Wire Type LVT ................................................................................................... 141
Thermostat Wire Type CL2................................................................................................... 142
Thermostat Wire, Unjacketed............................................................................................... 143
Carol® Helix/Hi-Temp® Category 6 Cable ............................................................................ 144
Carol® Helix/Hi-Temp® Category 5e Cable........................................................................... 145
8
Audio/Video & Home Entertainment Cable
146-177
Command® Series Home Entertainment Cables Guide...........................................147-148
Command® Series Cruise Ship Cables Guide ..........................................................149-150
Command® Series Speaker Cable................................................................................151-155
Speaker Wire........................................................................................................................ 156
Superflex® Speaker Wire...................................................................................................... 157
Pro Audio Speaker Wire....................................................................................................... 158
Special Audio, Communication & Instrumentation .......................................................159-161
Low Skew 4-Pair UTP.......................................................................................................... 162
SmartWrap™ Bundled Cable............................................................................................... 163
Direct Burial, Audio & Communication..........................................................................164-165
Digital Audio Snake Cable.................................................................................................... 166
Analog Audio Snake Cable ...........................................................................................167-168
Guitar/Instrument Cable....................................................................................................... 169
Ultra Flexible, Low Impedance 2-Conductor Microphone Cable ........................................ 170
Multi-Conductor, Flexfoil® Shield ......................................................................................... 171
Multi-Conductor, Rubber, Braid Shield Microphone Cable.................................................. 172
Multi-Conductor, Spiral Shield ............................................................................................. 173
Multi-Conductor, Braid Shield.............................................................................................. 174
Microphone Cable, Multi-Conductor, Carolprene®, Braid Shield......................................... 175
SMPTE-311 Hybrid Fiber Optic/Copper Camera Cable...................................................... 176
Electronic News Gathering/Field Production Camera Cable............................................... 177
tꢅblꢂ ꢀf cꢀꢃꢆꢂꢃꢆs
Section
PageS
9
Specialty Cable
178-185
Armored Electronics Products Guide........................................................................179-180
Wind Energy........................................................................................................................ 181
Fluorobus Cable ................................................................................................................... 182
Fire Wire ............................................................................................................................... 183
Computer Cable................................................................................................................... 184
Composite Data and Control Cable..................................................................................... 185
10 Technical Information
186-247
Insulation & Jacket Properties.............................................................................................. 187
Decimal Conversion Factors ................................................................................................ 188
Unit Conversion Factors....................................................................................................... 189
Temperature Conversion Chart ............................................................................................ 190
Conduit Capacity Chart........................................................................................................ 191
Coax Connector Cross Reference ................................................................................192-199
AWG Conductor Chart ......................................................................................................... 200
Cable Design Equations—Braid Shield................................................................................ 201
Cable Design Equations—Coaxial Cable............................................................................. 202
Cable Design Equations—Balanced Pair............................................................................. 203
Engineering Prefixes............................................................................................................. 204
Glossary.........................................................................................................................205-215
Abbreviations & Acronyms ............................................................................................216-218
Product Finder—Hook-Up Wire ........................................................................................... 219
Product Finder—Multi-Conductor Cable ......................................................................220-222
Product Finder—Multi-Paired Cable .............................................................................223-225
NEC/CEC Substitution Chart ........................................................................................226-227
Agency Symbols................................................................................................................... 228
Agency Approval Index ........................................................................................................ 229
Put-Ups and Color Codes.................................................................................................... 230
Applications Index.........................................................................................................231-233
Belden-to-General Cable Carol® Brand Cross Reference Index ..................................234-239
Part Number Index ........................................................................................................240-246
Notes .................................................................................................................................... 247
There is a reason
we call him –
Wire
Wizard.
SM
Alben Roland –Wire Wizard. When it comes to solving your problems, he makes magic happen.
Alben’s highest and most challenging form of wire wizardry is new product development, followed closely by
solving tough, often one-of-a-kind technical problems. His powers are also evident in quality control
and in laboratory testing. We call on Alben to perform his wizardry all the time. And so do our customers.
Alben, Manager, Product Engineering, Carol® Brand Electronic Products, and the entire team of General Cable
Wire Wizards are ready to perform magic. “Whether it’s providing a prototype, solving an applications problem,
or answering a technical question, we try to make magic happen,” explains Alben. Magic or not, our Wizards
always seem to find the answer and serve the customer. And there’s no smoke or mirrors about that.
If you’d like to put the powers of
Alben and General Cable Carol
Brand products to work for you,
talk to a General Cable rep
today. To connect, just call
1.888.295.5896 or e-mail us at
info@generalcable.com.
REEL People ... Adding REAL Value
www.generalcable.com
Making Contact with the World
Directing Traffic without Gridlock
Building Bridges in the Sky
General Cable is influencing the world … with more than two-thirds of our
sales generated outside North America and more than 11,000 associates in
45 manufacturing facilities throughout 22 countries. As one of the largest wire
and cable manufacturers, we are the One Company Connecting the World.
General Cable is a leader in the development,
design, manufacture, marketing and distribution
of copper, aluminum and fiber optic wire and
cable for the energy, industrial, specialty and
communications markets.
Energy Cables
Our cables carry energy across the world — through the air, underground
and under the sea. Increasing demand for energy is accelerating investment
in exploration, extraction, power generation, transmission and distribution —
whether based on coal, natural gas, oil, nuclear, wind, solar or water.
Our products inspire progress worldwide …
customers use our value-added products
to create global infrastructure that improves the
standard of living for people everywhere.
Industrial & Specialty Cables
Our cables channel the power and signals that make equipment hum and
engines run. From oil rigs and broadcast studios to cars and trains, and in
commercial buildings, public venues, factory floors and special applications
such as military, nuclear, marine and mining — we serve an extensive range
of markets.
Each day we’re building business momentum —
developing ideas into innovative solutions and
industry-leading products, expanding geographic
access and furthering our investment in highly
capable associates, Lean Manufacturing,
Communications Cables
Our cables keep information flowing — facilitating a non-stop stream of
words and images around the world. We meet the high-speed bandwidth
needs of global communications networks, from fiber optic submarine
communications cables, copper and fiber aerial and underground cables,
to copper and fiber optic enterprise cables and system solutions.
World Headquarters - General Cable
4 Tesseneer Drive • Highland Heights, KY • 41076-9753 U.S.A.
material science and technology resources.
Our Green Initiative symbol recognizes our role and responsibility in promoting
sustainability. The symbol also reflects our commitment to achieving industry-
leading standards and responding proactively to environmental global issues.
Look for our products with the RoHS symbol for your green building initiatives.
Visit www.generalcable.com
Select “company”, then select “environmental”
Electronics
Hꢀꢀk-Up Wꢁrꢂ
1
Index
Page
UL 1007, UL 1569,
CSA TR-64
2
3
4
UL 1015, CSA TEW
MIL-W-76B
UL Types MTW, TFF,
AWM & CSA TEW
5
Most applications of hook-up
and lead wire for board-to-
board or point-to-point wiring
rely on PVC-insulated designs.
Hook-up wire is also available
in special colors and/or stripe
combinations with a minimum
of lead time. In addition,
General Cable offers a variety
of put-ups to meet individual
customer requirements.
Heavy Wall UL Types MTW,
AWM & NEC Type THW
6
7
Rubber/PVC/Polyethylene
General Cable’s Carol® Brand
products offer both electrical
and electronic designers a vast
array of quality PVC hook-
up wire to meet the specific
technical demands of today,
with ‘‘off-the-shelf” distributor
inventoried products.
1
Electronics
Hook-Up Wire
UL 1007, UL 1569, cSa tR-64
Product Construction:
Conductor:
ꢀ
ꢀ
•ꢀꢀ24ꢀthruꢀ16ꢀAWGꢀ
•ꢀꢀFullyꢀannealedꢀtinnedꢀcopperꢀperꢀ
ASTM B-33
ꢀ
•ꢀꢀSolidꢀorꢀstranded
noM. inSULation
tHicKneSS
noMinaL o.D.
Insulation:
cataLog
nUMBeR
aWg
SiZe
conD.
StRanD
incHeS
mm
incHeS
mm
ꢀ
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+105˚C
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
SOLID CONDUCTORS
24
22
20
18
16
Solid
0.016
0.016
0.016
0.016
0.016
0.41
0.052
0.057
0.064
0.072
0.083
1.32
1.45
1.63
1.83
2.11
C2003A
C2004A
C2028A
C2052A
C2053A
Applications:
ꢀ
Solid
Solid
Solid
Solid
0.41
0.41
0.41
0.41
•ꢀꢀInternalꢀwiringꢀofꢀelectricalꢀandꢀelectronicꢀ
equipment
•ꢀꢀInternalꢀwiringꢀofꢀpanelsꢀandꢀmeters
•ꢀꢀPoint-to-pointꢀwiring
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
ꢀ
ꢀ
STRANDED CONDUCTORS
Compliances:
24
22
20
18
16
7/32
7/30
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.056
0.062
0.070
0.080
0.092
1.42
1.57
1.78
2.03
2.34
C2015A
C2016A
C2040A
C2064A
C2065A
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀStyleꢀ1007ꢀ–ꢀ80˚C,ꢀ300V
•ꢀꢀULꢀStyleꢀ1569ꢀ–ꢀ105˚C,ꢀ300V
•ꢀꢀCSAꢀTR-64ꢀ–ꢀ90°C,ꢀ300V
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀVW-1ꢀVerticalꢀWireꢀ
10/30
16/30
26/30
Flame Test
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart
oRDeRing
oRDeRing
SUFFiX
SUFFiX
coLoRS
Black
coLoRS
Green
Blue
01
02
03
04
06
07
08
10
19
White
Red
Brown
Gray
Orange
Yellow
Violet
05
Striped combinations available upon request; consult Customer Service.
2
Hook-Up Wire
Electronics
UL 1015, cSa teW
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀthruꢀ10ꢀAWGꢀ
ꢀ
•ꢀꢀFullyꢀannealedꢀtinnedꢀcopperꢀperꢀ
ASTM B-33
ꢀ
•ꢀꢀSolidꢀorꢀstranded
noM. inSULation
tHicKneSS
noMinaL o.D.
Insulation:
cataLog
nUMBeR
aWg
SiZe
conD.
StRanD
incHeS
mm
incHeS
mm
ꢀ
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+105˚C
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
SOLID CONDUCTORS
22
20
18
Solid
Solid
Solid
0.032
0.032
0.032
0.81
0.81
0.81
0.089
0.096
0.104
2.26
2.44
2.64
C2117A
C2118A
C2119A
Applications:
ꢀ
•ꢀꢀInternalꢀwiringꢀofꢀelectricalꢀandꢀelectronicꢀ
equipment
ꢀ
ꢀ
ꢀ
•ꢀꢀInternalꢀwiringꢀofꢀpanelsꢀandꢀmeters
•ꢀꢀPoint-to-pointꢀwiring
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ600ꢀvolts
STRANDED CONDUCTORS
24
22
20
18
16
14
12
10
7/32
7/30
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.033
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.84
0.088
0.094
0.102
0.112
0.124
0.141
0.160
0.184
2.24
2.39
2.59
2.84
3.15
3.58
4.06
4.67
C2100A
C2101A
C2102A
C2103A
C2104A
C2105A
C2106A
C2107A
Compliances:
10/30
16/30
26/30
41/30
65/30
105/30
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀStyleꢀ1015ꢀ–ꢀ105°C,ꢀ600V
•ꢀꢀCSAꢀTypeꢀTEW
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀVW-1ꢀVerticalꢀWireꢀ
Flame Test
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart
oRDeRing
oRDeRing
SUFFiX
SUFFiX
coLoRS
coLoRS
Green
Blue
Black
White
Red
01
02
03
04
06
07
08
10
19
Brown
Gray
Orange
Yellow
Violet
05
Striped combinations available upon request; consult Customer Service.
3
Electronics
Hook-Up Wire
MiL-W-76B
Type MW
Product Construction:
Conductor:
ꢀ
ꢀ
•ꢀꢀ24ꢀthruꢀ12ꢀAWG
•ꢀꢀFullyꢀannealedꢀstrandedꢀtinnedꢀcopperꢀ
per ASTM B-33
Insulation:
noM. inSULation
tHicKneSS
noMinaL o.D.
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
cataLog
nUMBeR
tYPe
aWg
SiZe
conD.
DeSignation
StRanD
incHeS
mm
incHeS
mm
•ꢀꢀTypeꢀMW:ꢀMediumꢀwall
•ꢀꢀTemperatureꢀrange:ꢀ-12°Cꢀtoꢀ+90°C
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
MIL-W-76B TYPE MW (MEDIUM WALL)
MW-C24(7)U
MW-C22(7)U
MW-C20(10)U
MW-C18(16)U
MW-C16(26)U
MW-C14(41)U
MW-C12(65)U
24
22
20
18
16
14
12
7/32
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.056
0.062
0.070
0.080
0.092
0.109
0.128
1.42
1.57
1.78
2.03
2.34
2.77
3.25
C7600A
C7602A
C7604A
C7606A
C7608A*
C7610A*
Applications:
•ꢀꢀInternalꢀwiringꢀofꢀelectricalꢀandꢀelectronicꢀ
equipment
•ꢀꢀInternalꢀwiringꢀofꢀpanelsꢀandꢀmeters
•ꢀꢀPoint-to-pointꢀwiring
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ1000ꢀvoltsꢀ
(MIL-W-76B)
•ꢀꢀNonꢀQPL
7/30
ꢀ
10/30
16/30
26/30
41/30
65/30
ꢀ
ꢀ
ꢀ
ꢀ
C7611A*
*-25˚Cꢀtoꢀ+105˚C
Compliances:
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
ꢀ
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart
oRDeRing
SUFFiX
oRDeRing
SUFFiX
coLoRS
coLoRS
Green
Blue
Black
White
Red
01
02
03
06
07
08
10
19
Brown
Gray
Orange
Yellow
04
05
Violet
Striped combinations available upon request; consult Customer Service.
4
Hook-Up Wire
Electronics
UL typꢂs MtW, tFF, aWM & cSa teW
90ºC 600 Volt MTW, TFF 105ºC 600 Volt AWM/TEW
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀthroughꢀ8ꢀAWGꢀfullyꢀannealedꢀ
stranded bare copper per ASTM B-8
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
noM. inSULation
tHicKneSS
aPPRoX.
StocK net WeigHt
coLoRS LBS/M(S)
noMinaL o.D.
incHeS mm
•ꢀꢀTemperatureꢀrange:ꢀ
cataLog
nUMBeR
aWg
SiZe
conD.
StRanD
MTW:ꢀ-40ºCꢀtoꢀ+90ºC
incHeS
mm
TEW/AWM:ꢀ-20ºCꢀtoꢀ+105ºC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
UL TYPE MTW, AWM, TFF, CSA TYPE TEW–600 VOLT
ꢀ
ꢀ
18
16
14
12
10
8
16/30
26/30
0.032
0.032
0.032
0.032
0.032
0.047
0.81
0.81
0.81
0.81
0.81
1.19
0.110
0.123
0.136
0.155
0.179
0.242
2.79
3.12
3.40
3.91
4.55
6.15
1-12
1-12
1-12
1-7
10
14
20
28
42
72
76502
76512
76812
76822
76832
76843
Jacket Marking:
•ꢀꢀ18ꢀandꢀ16ꢀAWG:
CAROL (SIZE) 600V E# MTW (UL) OR
TFF OR AWM VW-1 --- CSA TEW 105ºC
FT-1
•ꢀꢀ14ꢀthroughꢀ8ꢀAWG:
CAROL (SIZE) 600V E# MTW (UL) OR
AWM VW-1 --- CSA TEW 105ºC FT-1
19/.0159
19/.0185
19/.0234
19/.0295
ꢀ
1-5
1-5
(S) Actual shipping weight may vary.
Applications:
ꢀ
ꢀ
ꢀ
•ꢀꢀMotorꢀandꢀtransformerꢀlead
•ꢀꢀExternalꢀwiringꢀofꢀmachinery
•ꢀꢀInternalꢀwiringꢀofꢀelectricalꢀandꢀelectronicꢀ
equipment
•ꢀꢀInternalꢀwiringꢀofꢀpanelsꢀandꢀmeters
•ꢀꢀPoint-to-pointꢀwiring
Color Code Chart
oRDeRing
SUFFiX
oRDeRing
SUFFiX
ꢀ
ꢀ
coLoRS
Black
White
Red
coLoRS
Orange
Brown
Purple
Gray
01
02
03
07
04
08
19
10
Features:
ꢀ
•ꢀꢀOutstandingꢀoil,ꢀflameꢀandꢀmoistureꢀ
resistance
•ꢀꢀExtraꢀflexible
Blue
ꢀ
Green
Pink
06
13
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀandꢀNMTBAꢀTypeꢀMTW/AWM
•ꢀꢀCSAꢀTEW
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀPassesꢀVW-1ꢀVerticalꢀFlameꢀTest
•ꢀꢀAWMꢀStyleꢀ1015ꢀ–ꢀ18-8ꢀAWG
•ꢀꢀAWMꢀStyleꢀ1335ꢀ–ꢀ18-10ꢀAWG
•ꢀꢀAWMꢀStyleꢀ1336ꢀ–ꢀ8ꢀAWG
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
5
Electronics
Hook-Up Wire
Hꢂꢅvy Wꢅll UL typꢂs MtW, aWM & nec typꢂ tHW
90ºC 600 Volts
Product Construction:
Conductor:
ꢀ
•ꢀꢀ6ꢀandꢀ4ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
bare copper per ASTM B-8
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC,ꢀblack
noM. inSULation
tHicKneSS
aPPRoX.
net WeigHt
LBS/m(S)
noMinaL o.D.
•ꢀꢀTemperatureꢀrange:ꢀ-40ºCꢀtoꢀ+90ºC
cataLog
nUMBeR
aWg
SiZe
conD.
StRanD
incHeS
mm
incHeS
mm
Jacket Marking:
•ꢀꢀCAROLꢀ6ꢀAWGꢀ600VꢀE#ꢀMTWꢀORꢀTHWꢀ
AWM, MTW, THW – 600 VOLT – UL
ꢀ
(UL) OR AWM
6
4
19/.0372
0.064
0.065
1.63
1.65
0.315
0.365
8.00
9.27
110
150
76954
76994
Applications:
•ꢀꢀMotorꢀandꢀtransformerꢀlead
•ꢀꢀExternalꢀwiringꢀofꢀmachinery
19/.0469
ꢀ
ꢀ
(S)Actual shipping weight may vary.
Features:
ꢀ
•ꢀꢀOutstandingꢀoil,ꢀflameꢀandꢀmoistureꢀ
resistance
ꢀ
•ꢀꢀExtraꢀflexible
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀTypeꢀAWM
•ꢀꢀULꢀandꢀNMTBAꢀTypeꢀMTW
•ꢀꢀNECꢀTypeꢀTHW
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀPassesꢀULꢀVW-1ꢀVerticalꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
6
Hook-Up Wire
Electronics
Rubbꢂr/PVc/Pꢀlyꢂꢆhylꢂꢃꢂ
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20,ꢀ18ꢀandꢀ14ꢀAWG
ꢀ
•ꢀꢀFullyꢀannealedꢀstrandedꢀtinnedꢀcopperꢀ
per ASTM B-33
Insulation:
noM. inSULation
tHicKneSS
BReaKDoWn
VoLtage
noMinaL o.D.
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀrubber,ꢀ
cataLog no. oF aWg
nUMBeR conD. SiZe
conD.
WoRKing
PVC or polyethylene
•ꢀꢀTemperatureꢀrange:ꢀ
StRanD incHeS mm
(ac, rms)
VoLtage* incHeS mm
RUBBER TEST LEAD
ꢀ
ꢀ
ꢀ
-20˚Cꢀtoꢀ+60˚Cꢀrubber
-25˚Cꢀtoꢀ+60˚CꢀPVC
-20˚Cꢀtoꢀ+80˚Cꢀpolyethylene
1,500V
3,000V
5,000V
10,000V
1
1
1
1
20
20
18
18
41/36
41/36
65/36
65/36
0.040 1.02
0.047 1.19
0.045 1.14
0.088 2.24
6,000V
12,000V
20,000V
29,000V
0.125 3.18
0.140 3.56
0.145 3.68
0.230 5.84
C1326
C1319
C1321
C1318
ꢀ
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Applications:
•ꢀꢀTestꢀequipment
ꢀ
ꢀ
•ꢀꢀOscillators
PVC TEST LEAD
Compliances:
5,000V
600V
1
1
18
14
65/36
0.047 1.19
20,000V
0.140 3.56
0.140 3.56
C1320A
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
POLYETHYLENE TEST LEAD
Packaging:
105/34 0.032 0.81
4,000V
C7108A
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
*For intermittent duty only.
Color Code Chart
oRDeRing
SUFFiX
coLoRS
Black
01
Red
03
Green
06
7
Electronics
Communication & Control Cable, Multi-Conductor
2
Index
Page
Multi-Conductor,
Unshielded
9-17
Multi-Conductor,
Unshielded (CSA)
18-20
21
Multi-Conductor, Rubber,
Unshielded
The multi-conductor array of
communication and control
cable facilitates cable pull-ins
and single-site installations.
Foamed PP/PVC designs
use high speed, foamed
polypropylene insulations for
long-distance critical circuits,
which would not perform if
higher loss insulations were
employed.
Power-Limited Tray
Cable, Unshielded
22
Multi-Conductor,
Foil Shield
This cable is typically used for
industrial equipment control,
electric valve actuation and
remote signaling, as well as
23-28
29-31
32
Multi-Conductor,
Foil Shield (CSA)
FEP/FEP designs employ
communications and broadcast fluoropolymer 200°C-rated
applications. These designs
are available in a wide variety
of insulation and jacketing
materials, as well as shield
designs to alleviate unwanted
circuit noise.
materials. They are
Power-Limited Tray Cable,
Foil Shield
recommended for use in
applications where high
temperature, plenum rating,
electrical and mechanical safety
and chemical resistance are
essential.
Multi-Conductor,
Spiral Shield
33
General Cable’s Carol® Brand
products are manufactured
to meet the latest UL, CSA
and NEC requirements and
approvals.
Multi-Conductor,
Braid Shield
34-37
38
Rubber/Rubber is typically
employed in installations
characterized as severely hostile
environments, where these
designs provide unsurpassed
service life.
Multi-Conductor, Foil/Braid
Shield
A Design To Meet Every
Application
Multi-Conductor, Foil & TC
Braid Shield
39
® offers
Rubber/Carolprene
PVC/PVC designs employ
polyvinyl chloride insulations
and jackets capable of meeting
everyday, general purpose
applications.
the ultimate performance for
applications that demand the
greatest protection from the
environment, including physical
abuse. The specially formulated
Carolprene® jacket has been
proven time and again to
Multi-Conductor, Rubber,
Braid Shield
40
Multi-Conductor, Carolprene,®
Braid Shield
41
PE or PP/PVC designs employ
high quality polyethylene or
polypropylene insulations to
assure faithful reproduction
of transmitted signals across
interconnection circuits.
withstand all types of abuse,
both mechanical and chemical.
8
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Unshielded
UL 2464, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀFullyꢀannealedꢀtinnedꢀcopperꢀperꢀ
ASTM B-33 (C4008A, C4311A)
ꢀ
•ꢀꢀFullyꢀannealedꢀsolidꢀbareꢀcopperꢀperꢀ
ASTM B-3 (C2754A)
Insulation:
NOM.
C-C
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVCꢀ
NOMINAL O.D.
per UL 1061
CATALOG NO. OF AWG COND.
COLOR CAP.*
CODE pF/ft
NUMBER COND. SIZE STRAND INCHES
mm INCHES mm INCHES mm
0.25 0.032 0.81 0.156 3.94
0.25 0.032 0.81 0.166 4.22
0.25 0.032 0.81 0.176 4.47
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
ꢀ
ꢀ
Black/
24.5
2
2
2
22
20
19
Solid 0.010
Solid 0.010
Solid 0.010
C4008A
C4311A
C2754A
Red
Applications:
•ꢀꢀPublicꢀaddressꢀsystems
•ꢀꢀIntercoms
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Black/
28.0
Red
ꢀ
ꢀ
ꢀ
ꢀ
Brown/
29.5
Tan
*Capacitance between conductors
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
9
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Unshielded
UL 2464, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ18ꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVCꢀ(18ꢀ
AWG),ꢀS-RꢀPVCꢀ(22ꢀAWG)
ꢀ
ꢀ
NOM.
C-C
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
CATALOG NO. OF AWG COND.
CAP.*
pF/ft
Jacket:
NUMBER COND. SIZE STRAND INCHES
mm
INCHES
mm
0.81
0.81
0.81
0.81
INCHES
0.244
0.253
0.263
0.273
mm
6.20
6.43
6.69
6.94
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
4-22
2-18 16/30
7/30
0.010
0.016
0.25
0.41
24.5
31.0
6
7
8
9
0.032
0.032
0.032
0.032
C4081A
C4082A
C4083A
C4084A
Applications:
•ꢀꢀTVꢀantennaꢀrotorꢀcontrol
•ꢀꢀSatelliteꢀactuatorꢀcontrol
•ꢀꢀPublicꢀaddressꢀsystems
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
5-22 7/30
2-18 16/30
6-22 7/30
2-18 16/30
7-22 7/30
2-18 16/30
0.010
0.016
0.25
0.41
24.5
31.0
ꢀ
ꢀ
ꢀ
ꢀ
0.010
0.016
0.25
0.41
24.5
31.0
0.010
0.016
0.25
0.41
24.5
31.0
Features:
•ꢀꢀTinnedꢀcopperꢀconductorsꢀprovideꢀ
ꢀ
*Capacitance between conductors
excellent corrosion resistance
ꢀ
•ꢀꢀAssistsꢀwithꢀsolderingꢀapplications
Compliances:
Color Code Chart
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
NO. OF
COND.
COLOR
Black
White
Red
1 18 ga.
2
1 22 ga.
Green
Brown
Blue
2
3
4
5
6
7
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Orange
Yellow
Violet
10
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Unshielded
UL 2464, UL 2576, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVCꢀ
per UL 1061
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
NOM.
C-C
COLOR CAP.*
CODE pF/ft
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG COND.
Jacket:
•ꢀꢀPVC,ꢀgray
NUMBER COND. SIZE STRAND INCHES
mm INCHES mm INCHES mm
ꢀ
ꢀ
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
Black/
23.0
2
3
24
24
7/32
7/32
0.010
0.010
0.25 0.032 0.81 0.152 3.86
C2461A
C2462A
Red
Applications:
Black/
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPublicꢀaddressꢀsystems
•ꢀꢀIntercoms
•ꢀꢀInternalꢀtelephonesꢀ
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
0.25 0.032 0.81 0.163 4.14 Red/ 23.0
Green
4
5
24
24
24
24
24
24
24
24
24
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25 0.032 0.81 0.174 4.42
0.25 0.032 0.81 0.183 4.75
0.25 0.032 0.81 0.200 5.08
0.25 0.032 0.81 0.200 5.08
0.25 0.032 0.81 0.214 5.44
0.25 0.032 0.81 0.227 5.77
0.25 0.032 0.81 0.244 6.20
0.25 0.032 0.81 0.251 6.38
0.25 0.032 0.81 0.275 6.99
1
1
1
1
1
1
1
1
2
23.0
23.0
23.0
23.0
23.0
23.0
23.0
23.0
23.0
C2463A
C2464A
C2466A
C2488A
C2465A
C2470A
C2471A
C2467A
C2473A
6
Features:
7
ꢀ
ꢀ
ꢀ
•ꢀꢀEasyꢀtoꢀterminate
•ꢀꢀExcellentꢀelectricalꢀpropertiesꢀ
•ꢀꢀTinnedꢀconductorsꢀprovideꢀexcellentꢀ
corrosion resistance
8
9
10
12
15
ꢀ
•ꢀꢀAssistsꢀsolderingꢀapplications
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀULꢀStyleꢀ2576ꢀ(UL:ꢀ80˚C,ꢀ150V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
*Capacitance between conductors
Color Code Chart 1 - For cables up to and including 12 conductors
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Black
White
Red
Green
Brown
Blue
Orange
Yellow
Violet
Gray
Pink
Tan
1
2
3
4
5
6
7
8
Packaging:
ꢀ
9
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
10
11
12
Color Code Chart 2 Per ICEA - For cables with 15 conductors
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
COLOR
Black
White
Red
Green
Orange
Blue
White/Black
Red/Black
Green/Black
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
1
2
3
4
5
6
7
11
12
13
14
15
8
9
10
11
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Unshielded
UL 2464, UL 2576, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealed,ꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVCꢀ
per UL 1061
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
NOM.
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOMINAL O.D.
C-C
CATALOG NO. OF AWG COND.
COLOR CAP.*
mm CODE pF/ft
Jacket:
NUMBER COND. SIZE STRAND INCHES
mm INCHES mm INCHES
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80˚C
Black/
Red
Black/
2
3
22
22
7/30 0.010
7/30 0.010
0.25 0.015 0.38 0.130 3.30
24.5
C6348A†
C4062A
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPublicꢀaddressꢀsystems
•ꢀꢀIntercoms
•ꢀꢀInternalꢀtelephones
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
0.25 0.032 0.81 0.176 4.47 Red/ 24.5
Green
4
5
22
22
22
22
22
22
22
22
22
22
22
22
22
22
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
7/30 0.010
0.25 0.032 0.81 0.189 4.80
0.25 0.032 0.81 0.203 5.16
0.25 0.032 0.81 0.218 5.54
0.25 0.032 0.81 0.205 5.54
0.25 0.032 0.81 0.230 5.94
0.25 0.032 0.81 0.249 6.32
0.25 0.032 0.81 0.268 6.81
0.25 0.032 0.81 0.276 7.01
0.25 0.032 0.81 0.303 7.70
0.25 0.032 0.81 0.334 8.48
0.25 0.032 0.81 0.368 9.35
0.25 0.032 0.81 0.389 9.88
0.25 0.032 0.81 0.434 11.02
0.25 0.032 0.81 0.489 12.42
1
1
1
1
1
1
1
1
2
2
2
2
2
2
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
C4063A
C4064A
C4066A
C4088A
C4065A
C4070A
C4071A
C4067A
C4073A
C4075A
C4076A
C4077A
C4078A
C4079A
6
7
Features:
8
ꢀ
ꢀ
ꢀ
•ꢀꢀEasyꢀtoꢀterminate
•ꢀꢀExcellentꢀelectricalꢀproperties
•ꢀꢀTinnedꢀconductorsꢀprovideꢀexcellentꢀ
corrosion resistance
9
10
12
15
20
25
30
40
50
ꢀ
•ꢀꢀAssistsꢀsolderingꢀapplications
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀULꢀStyleꢀ2576ꢀ(UL:ꢀ80˚C,ꢀ150V)
•ꢀꢀCSAꢀCMGꢀ(CSAꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
*Capacitance between conductors
†CM-CSA CMG Only
Color Code Chart 1 - For cables up to and including 12 conductors
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
Packaging:
ꢀ
Black
White
Red
Green
Brown
Blue
Orange
Yellow
Violet
Gray
Pink
Tan
1
2
3
4
5
6
7
8
9
10
11
12
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart 2 Per ICEA - For cables of 15 thru 50 conductors
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
COLOR
COLOR
Black
White
Red
Green
Orange
Blue
White/Black
Red/Black
Green/Black
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
Black/Red
White/Red
Orange/Red
Blue/Red
Red/Green
Orange/Green
Black/White/Red
White/Black/Red
Red/Black/White
Green/Black/White
Orange/Black/White
Blue/Black/White
Black/Red/Green
White/Red/Green
Red/Black/Green
Green/Black/Orange
Orange/Black/Green
Blue/White/Orange
Black/White/Orange
White/Red/Orange
Orange/White/Blue
White/Red/Blue
White/Black/Green
Red/White/Green
Green/White/Blue
Orange/Red/Green
Blue/Red/Green
Black/White/Blue
White/Black/Blue
Red/White/Blue
Green/Orange/Red
Orange/Red/Blue
Blue/Red/Orange
Black/Orange/Red
1
2
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
3
4
5
6
7
8
9
10
11
12
13
Black/White/Green
12
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Unshielded
UL 2464, UL 2576, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20ꢀorꢀ18ꢀAWGꢀfullyꢀannealedꢀstranded,ꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVCꢀperꢀ
UL 1007
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
NOM.
C-C
COLOR CAP.*
CODE pF/ft
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG COND.
Jacket:
•ꢀꢀPVC,ꢀgray
NUMBER COND. SIZE STRAND INCHES
mm INCHES mm INCHES mm
ꢀ
ꢀ
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80°C
Black/
28.0
2
20
7/28 0.016
0.41 0.025 0.64 0.192 4.88
C6351A†
Red
Applications:
3
4
20
20
20
20
20
20
20
7/28 0.016
7/28 0.016
7/28 0.016
7/28 0.016
7/28 0.016
7/28 0.016
7/28 0.016
0.41 0.032 0.81 0.216 5.50
0.41 0.032 0.81 0.235 5.97
0.41 0.032 0.81 0.254 6.46
0.41 0.032 0.81 0.275 6.99
0.41 0.032 0.81 0.317 8.05
0.41 0.032 0.81 0.354 9.00
0.41 0.032 0.81 0.392 9.96
1
1
1
1
1
2
2
28.0
28.0
28.0
28.0
28.0
28.0
28.0
C6352A
C6353A
C6355A
C6356A
C6357A
C6360A
C6358A
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPublicꢀaddressꢀsystems
•ꢀꢀIntercoms
•ꢀꢀInternalꢀtelephones
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
5
7
9
12
15
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀULꢀStyleꢀ2576ꢀ(UL:ꢀ80˚C,ꢀ150V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Black/
Red
2
18 16/30 0.016
0.41 0.015 0.64 0.190 5.33
30.5
C2830A†
3
4
18 16/30 0.016
18 16/30 0.016
18 16/30 0.016
18 16/30 0.016
18 16/30 0.016
18 16/30 0.016
18 16/30 0.016
18 16/30 0.016
18 16/30 0.016
0.41 0.032 0.81 0.236 5.99
0.41 0.032 0.81 0.258 6.55
0.41 0.032 0.81 0.280 7.11
0.41 0.032 0.81 0.309 7.85
0.41 0.032 0.81 0.358 9.09
0.41 0.032 0.81 0.401 10.19
0.41 0.032 0.81 0.445 11.30
0.41 0.032 0.81 0.469 11.91
0.41 0.032 0.81 0.550 13.94
1
1
1
1
1
2
2
2
2
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
C2831A
C2404A
C2420A
C2421A
C2422A
C2412A
C2423A
C2424A
C2433A
5
7
9
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
12
15
19
25
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
*Capacitance between conductors
†CM (UL) c(UL), CSA CMG Only
Color Code Chart 1 - For cables up to and including 9 conductors
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
Black
White
Red
Green
Brown
Blue
1
2
3
4
5
6
7
8
9
Orange
Yellow
Violet
Color Code Chart 2 Per ICEA - For cables of 12 thru 25 conductors
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
COLOR
Black
White
Red
Green
Orange
Blue
White/Black
Red/Black
Green/Black
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
Black/Red
Blue/Red
Red/Green
Orange/Green
Black/White/Red
White/Black/Red
Red/Black/White
Green/Black/White
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
White/Red
Orange/Red
13
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Unshielded
UL 2464, UL 2587, NEC Type CL3 and CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
•ꢀꢀ16ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
ꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
C-C
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL O.D.
Jacket:
CATALOG NO. OF AWG
COND.
CAP.*
pF/ft
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
NUMBER COND. SIZE STRAND INCHES
mm
INCHES
mm
INCHES
mm
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+90°C
NEC TYPE CM, UL STYLE 2464 (80°C, 300 VOLTS)
Applications:
•ꢀꢀPublicꢀaddressꢀsystems
•ꢀꢀIntercoms
•ꢀꢀInternalꢀtelephones
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
2
3
16 19/.0117 0.021
16 19/.0117 0.021
16 19/.0117 0.021
16 19/.0117 0.021
16 19/.0117 0.021
16 19/.0117 0.021
16 19/.0117 0.021
16 19/.0117 0.021
16 19/.0117 0.021
16 19/.0117 0.021
16 19/.0117 0.021
0.53
0.53
0.53
0.53
0.53
0.53
0.53
0.53
0.53
0.53
0.53
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.260
0.283
0.306
0.334
0.363
6.81
7.19
7.77
8.48
9.25
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
C2405A
C2406A
C2425A
C2434A
C2426A
C2443A
C2435A
C2427A
C2428A
C2429A
C2436A
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
4
5
7
Compliances:
8
0.393 10.03
0.423 10.80
0.476 12.17
0.530 13.46
0.559 14.33
0.657 16.69
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL3ꢀ(UL:ꢀ75°C)
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀULꢀStyleꢀ2587ꢀ(UL:ꢀ90°C,ꢀ600V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
9
12
15
19
25
NEC TYPE CL3, UL STYLE 2587 (90°C, 600 VOLTS)
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
C2409A†
C2430A
C2437A
C2431A
2
4
5
7
14 19/.0147 0.030
14 19/.0147 0.032
14 19/.0147 0.032
14 19/.0147 0.032
0.81
0.81
0.81
0.81
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.326
0.391
8.51
9.93
29.0
28.2
28.2
28.2
Packaging:
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
ꢀ
packaging and color options
0.428 10.87
0.469 11.91
C2410A
C2440A
2
4
12 19/0.0185 0.032
12 19/0.0185 0.032
0.81
0.81
0.032
0.032
0.81
0.81
0.366
9.40
31.0
31.0
0.437 11.02
*Capacitance between conductors
†CL3,ꢀUL2587,ꢀCSAꢀCMHꢀOnly
Color Code Chart Per ICEA
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
COLOR
Black
White
Red
Green
Orange
Blue
White/Black
Red/Black
Green/Black
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
Black/Red
Blue/Red
Red/Green
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Orange/Green
Black/White/Red
White/Black/Red
Red/Black/White
Green/Black/White
White/Red
Orange/Red
14
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Unshielded
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFEP
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. C-C
CAP.*
pF/ft
NOMINAL O.D.
Jacket:
•ꢀꢀFlexguard®ꢀPVC,ꢀnaturalꢀorꢀasꢀrequested
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
CATALOG NO. OF AWG
COND.
ꢀ
ꢀ
NUMBER COND. SIZE STRAND INCHES
mm INCHES mm INCHES mm
4
18 19/30 TC 0.007
0.18 0.014 0.36 0.178 4.52
21.5
Applications:
C8102
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀAudioꢀsystems
*Capacitance between conductors
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Color Code Chart
Compliances:
NO. OF
COND.
COLOR
Black
White
Red
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀ(UL:ꢀ75°C,ꢀ300V)
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
1
2
3
4
Features:
Green
ꢀ
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
15
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Unshielded
NEC Type CMP (UL) c(UL) and/or CL2P
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ14ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned or bare copper per ASTM B-3,
B-8 or B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
PVC
NOM.
C-C
CAP.*
pF/ft
NOM. INSULATION NOM. JACKET
THICKNESS
THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
STRAND
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
INCHES mm INCHES mm INCHES mm
Jacket:
22 AWG CONDUCTORS
ꢀ
ꢀ
ꢀ
•ꢀꢀFluoropolymer,ꢀnatural
2
4
22
22
7/30 TC
0.006 0.15 0.010 0.25 0.089 2.26
0.006 0.15 0.010 0.25 0.121 3.07
29.0
29.0
C3105†
C3106†
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
•ꢀꢀSequentialꢀfootageꢀmarkedꢀtoꢀfacilitateꢀ
installation
•ꢀꢀIncludesꢀripcord
7/30 TC
18 AWG CONDUCTORS
ꢀ
2
3
18
18
18
18
18
18
18
18
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
0.008 0.20 0.010 0.25 0.123 3.12
0.008 0.20 0.010 0.25 0.143 3.63
0.008 0.20 0.010 0.25 0.163 4.14
0.008 0.20 0.010 0.25 0.187 4.75
0.008 0.20 0.010 0.25 0.198 5.03
0.008 0.20 0.010 0.25 0.223 5.66
0.008 0.20 0.010 0.25 0.244 6.19
0.008 0.20 0.010 0.25 0.263 6.68
31.0
31.0
31.0
30.8
31.0
31.0
31.0
31.0
C3102
C3190
C3103
C3134
C3192
C3191
C3178
C3179
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀIntercomꢀsystems
•ꢀꢀBackgroundꢀmusic
•ꢀꢀAudioꢀsystems
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ150ꢀvolts
4
5
6
8
Compliances:
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀ(UL:ꢀ75°C,ꢀ150V)
•ꢀꢀNECꢀArticleꢀ800ꢀ(UL:ꢀ75°C,ꢀ300V)
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
10
12
16 AWG CONDUCTORS
2
3
4
16 19/.0117 BC 0.008 0.20 0.010 0.25 0.141 3.58
16 7/.0192 BC 0.008 0.20 0.010 0.25 0.164 4.17
16 7/.0192 BC 0.008 0.20 0.010 0.25 0.187 4.75
33.0
33.0
33.0
C3193
C3194
C3195
Features:
ꢀ
•ꢀꢀAbrasion-,ꢀchemical-ꢀandꢀwater-resistant
jacket
Packaging:
14 AWG CONDUCTORS
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
2
2
14 19/.0147 BC 0.010 0.25 0.010 0.25 0.168 4.27
35.0
37.0
C3126†
C3135†
packaging and color options
12 AWG CONDUCTORS
12 19/.0185 BC 0.010 0.25 0.010 0.25 0.238 6.05
*Capacitance between conductors
†CL2P only
Color Code Chart
NO. OF
COND.
COLOR
Black
White
Red
1
2
3
Green
Brown
Blue
4
5
6
Orange
Yellow
Violet
Gray
7
8
9
10
11
12
Pink
Tan
16
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Unshielded
NEC Type CMP (UL) c(UL) and/or CL3P
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolid,ꢀ
stranded tinned or bare copper per
ASTM B-3, B-8 or B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
PVC
NOM.*
C-C
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
INCHES mm INCHES mm INCHES mm
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
STRAND
CAP.
Jacket:
pF/ft
ꢀ
ꢀ
ꢀ
•ꢀFꢀ lexguard®ꢀPVC,ꢀnatural
•ꢀꢀTemperatureꢀrange:ꢀ0°Cꢀtoꢀ+75°C
22 AWG CONDUCTORS
2
4
22
22
7/32 TC
0.008 0.20 0.015 0.38 0.122 3.10
0.008 0.20 0.015 0.38 0.141 3.58
30.0
30.0
C3115
C3116
•ꢀꢀSequentialꢀfootageꢀmarkedꢀtoꢀfacilitateꢀ
7/32 TC
installation
ꢀ
•ꢀꢀIncludesꢀripcord
18 AWG CONDUCTORS
2
3
18
18
18
18
18
18
18
18
18
18
18
18
18
18
Solid BC
Solid BC
Solid BC
Solid BC
Solid BC
Solid BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
0.008 0.20 0.015 0.38 0.142 3.61
0.008 0.20 0.015 0.38 0.151 3.84
0.008 0.20 0.015 0.38 0.166 4.22
0.008 0.20 0.015 0.38 0.182 4.62
0.008 0.20 0.015 0.38 0.199 5.05
0.008 0.20 0.015 0.38 0.216 5.49
0.008 0.20 0.015 0.38 0.156 3.96
0.008 0.20 0.015 0.38 0.166 4.22
0.008 0.20 0.015 0.38 0.182 4.62
0.008 0.20 0.015 0.38 0.200 5.08
0.008 0.20 0.015 0.38 0.216 5.49
0.008 0.20 0.015 0.38 0.239 6.07
0.008 0.20 0.015 0.38 0.278 7.06
0.008 0.20 0.015 0.38 0.287 7.29
37.0
37.0
37.0
37.0
37.0
37.0
35.0
35.0
35.0
54.6
35.0
35.0
35.0
35.0
Applications:
C3110
C3114
C3111
C3117
C3118
C3119
C3112
C3120
C3113
C3125
C3121
C3122
C3123
C3124
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀIntercomꢀsystems
•ꢀꢀBackgroundꢀmusic
•ꢀꢀAudioꢀsystems
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ150ꢀvolts
4
5
6
8
Compliances:
2
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀ(UL:ꢀ75°C,ꢀ150V)
•ꢀꢀNECꢀArticleꢀ800ꢀ(UL:ꢀ75°C,ꢀ300V)
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
3
4
5
6
8
Features:
10
12
ꢀ
•ꢀFlexible
ꢀ
•ꢀEasyꢀtoꢀterminate
16 AWG CONDUCTORS
Packaging:
2
2
2
16 19/.0117 BC .009
.227 0.015 0.38 0.178 4.52
40.0
40.0
43.0
C3127
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
14 AWG CONDUCTORS
14 19/.0147 BC 0.010 0.20 0.015 0.38 0.212 5.38
†
C3128
12 AWG CONDUCTORS
12 19/.0185 BC 0.010 0.20 0.015 0.38 0.254 6.45
†
C3129
*Capacitance between conductors
†CL3P only
Color Code Chart
NO. OF
COND.
COLOR
Black
White
Red
1
2
3
4
5
6
7
8
Green
Brown
Blue
Orange
Yellow
17
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Unshielded
AWMꢀStyleꢀ2464,ꢀCSAꢀTypeꢀAWMꢀI/IIꢀA/B,ꢀNEC/CECꢀTypeꢀCMGꢀ(CSAꢀC/US)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealed,ꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVCꢀ
NOM.
C-C
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelowꢀ
NO.
NOMINAL O.D.
Jacket:
CATALOG OF AWG COND.
COLOR CAP.*
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
CODE
pF/ft
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+105°C
Black/
Red
Black/
2
3
22
22
7/30 0.010 0.25 0.032 0.81 0.165
7/30 0.010 0.25 0.032 0.81 0.176
4.19
27.5
C4100A
C4101A
Applications:
•ꢀꢀPublicꢀaddressꢀsystems
•ꢀꢀIntercoms
•ꢀꢀInternalꢀtelephones
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀorꢀ600ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
4.47 Red/
Green
27.5
4
5
6
7
8
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
7/30 0.010 0.25 0.032 0.81 0.189
7/30 0.010 0.25 0.032 0.81 0.203
7/30 0.010 0.25 0.032 0.81 0.208
7/30 0.010 0.25 0.032 0.81 0.218
7/30 0.010 0.25 0.032 0.81 0.234
7/30 0.010 0.25 0.032 0.81 0.249
7/30 0.010 0.25 0.032 0.81 0.268
7/30 0.010 0.25 0.032 0.81 0.276
7/30 0.010 0.25 0.032 0.81 0.303
7/30 0.010 0.25 0.032 0.81 0.318
7/30 0.010 0.25 0.032 0.81 0.334
7/30 0.010 0.25 0.032 0.81 0.368
7/30 0.010 0.25 0.032 0.81 0.389
4.80
5.16
5.28
5.54
5.94
6.32
6.81
7.01
7.70
8.08
8.48
9.35
9.88
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
C4102A
C4103A
C4104A
C4105A
C4106A
C4107A
C4108A
C4109A
C4110A
C4111A
C4112A
C4113A
C4114A
C4115A
C4116A
volts
9
Features:
•ꢀꢀEasyꢀtoꢀterminate
•ꢀꢀExcellentꢀelectricalꢀproperties
•ꢀꢀTinnedꢀconductorsꢀprovideꢀexcellentꢀ
corrosion resistance
•ꢀꢀAssistsꢀsolderingꢀapplications
10
12
15
18
20
25
30
40
50
ꢀ
ꢀ
ꢀ
ꢀ
Compliances:
•ꢀꢀAWMꢀStyleꢀ2464ꢀ(CSA:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀTypeꢀAWMꢀ(105˚C,ꢀ600V)
•ꢀꢀCSAꢀCertifiedꢀCMGꢀtoꢀharmonizedꢀ
standard UL444 and CSA 22.2 No. 214
•ꢀꢀNEC/CECꢀTypeꢀCMGꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀCSAꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
•ꢀꢀPassesꢀCSAꢀFT4ꢀverticalꢀflameꢀtest
ꢀ
ꢀ
ꢀ
7/30 0.010 0.25 0.032 0.81 0.434 11.02
7/30 0.010 0.25 0.032 0.81 0.489 12.42
*Capacitance between conductors
Color Code Chart 1– For cables up to and including 12 conductors
ꢀ
ꢀ
ꢀ
NO. OF
COND.
NO. OF
COND.
COLOR
Black
White
Red
Green
Brown
Blue
COLOR
Orange
Yellow
Violet
Gray
Pink
1
2
3
4
5
6
7
8
9
10
11
12
ꢀ
Packaging:
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
ꢀ
Tan
packaging and color options
Color Code Chart 2 Per ICEA – For cables of 15 thru 50 conductors
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
COLOR
White/Red/Orange
Orange/White/Blue
White/Red/Blue
Black/White/Green
White/Black/Green
Red/White/Green
Green/White/Blue
Orange/Red/Green
Blue/Red/Green
Black/White/Blue
White/Black/Blue
Red/White/Blue
Green/Orange/Red
Orange/Red/Blue
Blue/Red/Orange
Black/Orange/Red
Black
Orange/Red
1
2
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
White
Blue/Red
Red
Red/Green
Orange/Green
3
Green
4
Orange
BlackWhite/Red
White/Black/Red
Red/Black/White
Green/Black/White
Orange/Black/White
Blue/Black/White
Black/Red/Green
White/Red/Green
Red/Black/Green
Green/Black/Orange
Orange/Black/Green
Blue/White/Orange
Black/White/Orange
5
Blue
6
White/Black
Red/Black
Green/Black
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
Black/Red
White/Red
7
8
9
10
11
12
13
14
15
16
17
18
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Unshielded
AWMꢀStyleꢀ2464,ꢀCSAꢀTypeꢀAWMꢀI/IIꢀA/B,ꢀNEC/CECꢀTypeꢀCMGꢀ(CSAꢀC/US)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20ꢀorꢀ18ꢀAWGꢀfullyꢀannealed,ꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
NOM.
C-C
Jacket:
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NO.
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
CATALOG OF AWG COND.
NUMBER COND. SIZE STRAND
COLOR CAP.*
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+105°C
CODE
pF/ft
Applications:
Black/
Red
2
20
7/28 0.016 0.41 0.032 0.81 0.206
5.23
25.0
C4117A
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPublicꢀaddressꢀsystems
3
4
20
20
20
20
20
20
20
7/28 0.016 0.41 0.032 0.81 0.216
7/28 0.016 0.41 0.032 0.81 0.235
7/28 0.016 0.41 0.032 0.81 0.254
7/28 0.016 0.41 0.032 0.81 0.275
7/28 0.016 0.41 0.032 0.81 0.317
7/28 0.016 0.41 0.032 0.81 0.354
7/28 0.016 0.41 0.032 0.81 0.392
5.49
5.97
6.45
6.99
8.05
8.99
9.96
1
1
1
1
1
2
2
25.0
25.0
25.0
25.0
25.0
25.0
25.0
C4118A
C4119A
C4120A
C4121A
C4122A
C4123A
C4124A
•ꢀꢀIntercoms
•ꢀꢀInternalꢀtelephones
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀorꢀ600ꢀ
5
7
9
volts
12
15
Features:
ꢀ
ꢀ
ꢀ
•ꢀꢀEasyꢀtoꢀterminate
•ꢀꢀExcellentꢀelectricalꢀproperties
•ꢀꢀTinnedꢀconductorsꢀprovideꢀexcellentꢀ
corrosion resistance
Black/
Red
2
18 16/30 0.016 0.41 0.032 0.81 0.224
5.69
27.5
C4125A
2
3
18 16/30 0.016 0.41 0.032 0.81 0.224
18 16/30 0.016 0.41 0.032 0.81 0.236
18 16/30 0.016 0.41 0.032 0.81 0.258
18 16/30 0.016 0.41 0.032 0.81 0.280
18 16/30 0.016 0.41 0.032 0.81 0.304
18 16/30 0.016 0.41 0.032 0.81 0.309
18 16/30 0.016 0.41 0.032 0.81 0.358
5.69
5.99
6.55
7.11
7.72
7.85
9.09
1
1
1
1
1
1
1
2
2
2
2
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
C4214A
C4126A
C4127A
C4128A
C4206A
C4129A
C4130A
C4131A
C4132A
C4133A
C4134A
ꢀ
•ꢀꢀAssistsꢀsolderingꢀapplications
4
Compliances:
5
ꢀ
ꢀ
ꢀ
•ꢀꢀAWMꢀStyleꢀ2464ꢀ(CSA:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀTypeꢀAWMꢀ(105˚C,ꢀ600V)
•ꢀꢀCSAꢀCertifiedꢀCMGꢀtoꢀharmonizedꢀ
standard UL444 and CSA 22.2 No. 214
6
7
9
12
15
19
25
18 16/30 0.016 0.41 0.032 0.81 0.401 10.19
18 16/30 0.016 0.41 0.032 0.81 0.445 11.30
18 16/30 0.016 0.41 0.032 0.81 0.469 11.91
18 16/30 0.016 0.41 0.032 0.81 0.549 13.94
ꢀ
ꢀ
ꢀ
•ꢀꢀNEC/CECꢀTypeꢀCMGꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀCSAꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
*Capacitance between conductors
ꢀ
•ꢀꢀPassesꢀCSAꢀFT4ꢀverticalꢀflameꢀtest
Packaging:
Color Code Chart 1 - For cables up to and including 9 conductors
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
NO. OF
COND.
NO. OF
COND.
6
7
8
9
packaging and color options
COLOR
Black
COLOR
Blue
1
2
3
4
5
White
Red
Green
Brown
Orange
Yellow
Violet
Color Code Chart 2 Per ICEA - For cables of 12 thru 25 conductors
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
COLOR
Black
White
Red
Green
Orange
Blue
White/Black
Red/Black
Green/Black
COLOR
COLOR
Blue/Red
Red/Green
Orange/Green
Black/White/Red
White/Black/Red
Red/Black/White
Green/Black/White
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
Black/Red
White/Red
Orange/Red
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
19
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Unshielded
AWMꢀStylesꢀ2464,ꢀ2587,ꢀCSAꢀTypeꢀAWMꢀI/IIꢀA/B,ꢀNEC/CECꢀTypeꢀCMGꢀ(CSAꢀC/US),ꢀ
or NEC Type CL2
Product Construction:
Conductor:
ꢀ
•ꢀꢀ16ꢀthruꢀ12ꢀAWGꢀfullyꢀannealed,ꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
C-C
CAP.*
pF/ft
Jacket:
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
STRAND
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+105°C
NUMBER
COND. SIZE
INCHES mm INCHES mm INCHES mm
AWM STYLE 2464, CSA TYPE AWM, CSA C/US TYPE CMG
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPublicꢀaddressꢀsystems
•ꢀꢀIntercoms
•ꢀꢀInternalꢀtelephones
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
2
3
16
16
16
16
16
16
16
16
16
16
16
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.53 0.032 0.81 0.268 6.81 27.0
0.53 0.032 0.81 0.283 7.19 27.0
0.53 0.032 0.81 0.306 7.77 27.0
0.53 0.032 0.81 0.334 8.48 27.0
0.53 0.032 0.81 0.364 9.25 27.0
0.53 0.032 0.81 0.395 10.03 27.0
0.53 0.032 0.81 0.425 10.80 27.0
0.53 0.032 0.81 0.479 12.17 27.0
0.53 0.032 0.81 0.530 13.46 27.0
0.53 0.032 0.81 0.564 14.33 27.0
0.53 0.032 0.81 0.657 16.69 27.0
C4135A
C4136A
C4137A
C4138A
C4139A
C4140A
C4141A
C4142A
C4143A
C4144A
C4145A
4
5
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀorꢀ600ꢀ
volts
7
8
Features:
ꢀ
ꢀ
ꢀ
•ꢀꢀEasyꢀtoꢀterminate
•ꢀꢀExcellentꢀelectricalꢀproperties
•ꢀꢀTinnedꢀconductorsꢀprovideꢀexcellentꢀ
corrosion resistance
9
12
15
19
25
ꢀ
•ꢀꢀAssistsꢀsolderingꢀapplications
Compliances:
ꢀ
•ꢀꢀAWMꢀStyleꢀ2464ꢀ(CSAꢀorꢀUL:ꢀ80˚C,ꢀ
300V)
AWM STYLE 2587, CSA TYPE AWM (FT4), NEC TYPE CL2**
ꢀ
ꢀ
ꢀ
•ꢀꢀAWMꢀStyleꢀ2587ꢀ(CSA:ꢀ90˚C,ꢀ600V)
•ꢀꢀCSAꢀTypeꢀAWMꢀ(105˚C,ꢀ600V)
•ꢀꢀCSAꢀCertifiedꢀCMGꢀtoꢀharmonizedꢀ
standard UL444 and CSA 22.2 No. 214
•ꢀꢀNEC/CECꢀTypeꢀCMGꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀCSAꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
•ꢀꢀPassesꢀCSAꢀFT4ꢀVerticalꢀFlameꢀTest
•ꢀꢀULꢀCertifiedꢀCL2ꢀtoꢀStandardꢀUL13**
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
2
4
5
7
2
4
14
14
14
14
12
12
19/.0147
19/.0147
19/.0147
19/.0147
19/.0185
19/.0185
0.032
0.032
0.032
0.032
0.032
0.032
0.81 0.032 0.81 0.334 8.48 25.0
0.81 0.032 0.81 0.391 9.93 25.0
0.81 0.032 0.81 0.428 10.87 25.0
0.81 0.032 0.81 0.469 11.91 25.0
0.81 0.032 0.81 0.370 9.40 29.4
0.81 0.032 0.81 0.434 11.02 29.4
C4146A
C4147A
C4148A
C4149A
C4150A
C4151A
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
* Capacitance between conductors
Color Code Chart Per ICEA
Packaging:
NO. OF
NO. OF
COND.
NO. OF
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
COND.
COLOR
Black
COLOR
COND.
COLOR
Blue/Red
packaging and color options
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
Black/Red
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
White
Red/Green
Red
Orange/Green
Green
Black/White/Red
White/Black/Red
Red/Black/White
Green/Black/White
Orange
Blue
White/Black
Red/Black
Green/Black
White/Red
Orange/Red
20
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Rubber, Unshielded
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀrubber
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
Jacket:
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
ꢀ
ꢀ
•ꢀꢀRubber,ꢀblack
NUMBER COND. SIZE STRAND INCHES
mm
INCHES
mm
INCHES
mm
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+60˚C
2
3
20
20
20
20
20
20
20
20
26/34
26/34
26/34
26/34
26/34
26/34
26/34
26/34
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.035
0.035
0.035
0.035
0.035
0.035
0.035
0.035
0.89
0.89
0.89
0.89
0.89
0.89
0.89
0.89
0.230
0.255
0.260
0.300
0.315
0.347
0.260
0.410
5.84
6.48
6.60
7.62
8.00
8.81
9.14
10.41
C3602
C3603
C3604
C3605
C3606
C3607
C3608
C3610
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀEnergyꢀmanagementꢀsystems
•ꢀꢀControlꢀcircuits
•ꢀꢀFireꢀalarmꢀcontrol
•ꢀꢀBroadcastꢀandꢀstudioꢀrequirements
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ350ꢀvolts
4
5
6
Features:
7
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀExcellentꢀimpactꢀresistance
•ꢀꢀHighꢀlevelꢀofꢀabrasionꢀresistance
•ꢀꢀHighꢀflexibility
•ꢀꢀExcellentꢀmechanicalꢀstrength
•ꢀꢀExcellentꢀmoistureꢀresistance
8
10
Compliances:
Color Code Chart
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
NO. OF
COND.
COLOR
Packaging:
Black
White
Red
1
2
3
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Green
Blue
4
5
Brown
Yellow
Orange
Gray
6
7
8
9
Violet
10
21
Electronics
Communication & Control Cable, Multi-Conductor
Power-Limited Tray Cable, Unshielded
NEC Type PLTC
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
C-C
CAP.*
pF/ft
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL O.D.
Jacket:
CATALOG NO. OF AWG COND.
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
NUMBER COND. SIZE STRAND INCHES
mm
INCHES
mm
INCHES
mm
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+105°C
2
3
2
3
2
3
4
2
3
2
3
2
22
22
20
20
18
18
18
7/30
7/30
0.013
0.013
0.013
0.013
0.015
0.015
0.015
0.33
0.33
0.33
0.33
0.38
0.38
0.38
0.33
0.33
0.33
0.33
0.33
0.037
0.037
0.037
0.037
0.037
0.037
0.037
0.037
0.037
0.042
0.042
0.042
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.94
1.07
1.07
1.07
0.190
0.198
0.206
0.216
0.226
0.237
0.257
0.243
0.250
0.288
0.290
0.315
4.83
5.03
5.23
5.49
5.74
6.02
6.53
6.17
6.35
7.32
7.37
8.00
27.5
27.5
30.5
30.5
31.5
31.5
31.5
37.0
37.0
40.5
40.5
44.0
C0431A
C0432A
C0433A
C0434A
C0435A
C0436A
C0444A
C0437A
C0438A
C0439A
C0440A
C0441A
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀCableꢀtrayꢀinstallations
•ꢀꢀPowerꢀlimitedꢀcircuits
•ꢀꢀIntercomꢀsystems
•ꢀꢀBusinessꢀmachines
•ꢀꢀCashꢀregisters
•ꢀꢀAutomaticꢀvalveꢀcontrolꢀsystems
•ꢀꢀIrrigationꢀsystems
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
•ꢀꢀBurglarꢀalarms
7/28
7/28
16/30
16/30
16/30
16 19/.0117 0.013
16 19/.0117 0.013
14 19/.0147 0.013
14 19/.0147 0.013
12 19/.0185 0.013
Features:
ꢀ
•ꢀꢀSunlight-resistantꢀPVCꢀjacket
ꢀ
•ꢀꢀULꢀratedꢀforꢀcableꢀtrayꢀuse
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀPower-LimitedꢀTrayꢀ
Cableꢀ(UL:ꢀ105°C,ꢀ300V)
*Capacitance between conductors
ꢀ
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀMeetsꢀULꢀ70,000ꢀBTUꢀVerticalꢀTrayꢀ
Flame Test
Color Code Chart
Packaging:
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
NO. OF
ꢀ
COND.
COLOR
Black
Red
packaging and color options
1
2
3
4
White
Green
22
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Foil Shield
NECꢀTypeꢀCL2ꢀandꢀCMꢀ(UL)ꢀc(UL)ꢀCMH
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀorꢀ
stranded tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.***
NOMINAL O.D.
polyethylene
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
pF/ft
CATALOG NO. OF AWG COND.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
A
B
UL STYLE 2092, CM (UL) C(UL) CMH, 300V
2
2
2
2
24
22
20
18
7/32
0.016 0.41 0.026 0.66 0.167 4.24 18.0 33.0
0.016 0.41 0.020 0.51 0.167 4.24 20.0 36.0
0.016 0.41 0.020 0.51 0.183 4.65 22.5 40.5
0.016 0.41 0.020 0.51 0.201 5.21 25.5 45.5
C2513A
C2514A
C2524A
C2534A
Shield:
7/30
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
7/28
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
16/30
PolyethyleneꢀInsulation,ꢀColorꢀCodeꢀChartꢀ#1
Jacket:
•ꢀꢀPVC,ꢀgray
UL STYLE 2093, CM (UL) c(UL) CMH, 300V
ꢀ
ꢀ
3
3
3
3
22
20
20
18
7/30
0.016 0.41 0.030 0.76 0.196 4.98 18.5 33.5
0.016 0.41 0.030 0.76 0.210 5.34 21.0 37.5
0.016 0.41 0.030 0.76 0.213 5.41 21.0 37.0
0.016 0.41 0.020 0.51 0.213 5.56 23.0 41.0
C2526A
C2528A
C2525A
C2535A
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
7/28
Applications:
7/28
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀRecordingꢀstudiosꢀandꢀsoundꢀstages
•ꢀꢀBroadcastꢀandꢀsoundꢀsystems
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipmentꢀcontrol
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀorꢀ600ꢀ
16/30
PolyethyleneꢀInsulation,ꢀColorꢀCodeꢀChartꢀ#1
UL STYLE 2094, CM (UL) c(UL) CMH, 300V
4
4
22
20
7/30
7/28
0.016 0.41 0.030 0.76 0.213 5.41 18.5 33.5
0.016 0.41 0.030 0.76 0.234 5.94 20.5 36.5
C2523A
C2555A
volts
Features:
PolyethyleneꢀInsulation,ꢀColorꢀCodeꢀChartꢀ#1
ꢀ
ꢀ
ꢀ
•ꢀꢀExcellentꢀelectricalꢀproperties
•ꢀꢀSuperiorꢀshieldingꢀeffectivenessꢀ
•ꢀꢀ25%ꢀshieldꢀoverlapꢀprovidesꢀexcellentꢀ
shielding efficiency
UL STYLE 2106, CSA, 600V
2
2
2
16 19/.0117 0.031 0.79 0.032 0.81 0.307 7.80 20.0 36.0
14 19/.0147 0.031 0.79 0.032 0.81 0.335 8.51 23.0 42.0
12 19/.0185 0.032 0.81 0.032 0.81 0.376 9.55 26.0 46.0
C2536A*
C2538A**
C2539A**
ꢀ
•ꢀꢀGoodꢀflexibility
Compliances:
*ꢀCMꢀ(UL)ꢀc(UL)ꢀCMH
** CL2
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀStyleꢀ2092ꢀ(UL:ꢀ60°C,ꢀ300V)
•ꢀꢀULꢀStyleꢀ2093ꢀ(UL:ꢀ60°C,ꢀ300V)
•ꢀꢀULꢀStyleꢀ2094ꢀ(UL:ꢀ60°C,ꢀ300V)
•ꢀꢀULꢀStyleꢀ2106ꢀ(UL:ꢀ60°C,ꢀ600V)
•ꢀꢀULꢀStyleꢀ2107ꢀ(UL:ꢀ60°C,ꢀ600V)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL2ꢀ(UL:ꢀ75°C)
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
PolyethyleneꢀInsulation,ꢀColorꢀCodeꢀChartꢀ#1
UL STYLE 2107, CM (UL) c(UL) CMH, 600V
3
16 19/.0117 0.031 0.79 0.032 0.81 0.325 8.26 19.0 34.0
C2537A
PolyethyleneꢀInsulation,ꢀColorꢀCodeꢀChartꢀ#1
UL STYLE 2464, CL2/CM (UL) c(UL) CMH, 300V
2
20
7/28
0.013 0.33 0.032 0.81 0.194
4.9 49.7 89.5
C2540A
PVCꢀInsulation,ꢀColorꢀCodeꢀChartꢀ#2
CM (UL) c(UL) CMH, 300V
2
2
3
22
22
22
Solid
7/30
7/30
0.007 0.18 0.020 0.51 0.124 3.15 30.0 55.0
0.008 0.20 0.020 0.51 0.137 3.48 28.0 51.0
0.008 0.20 0.020 0.51 0.144 3.36 25.0 45.0
C2515A
C2516A
C2517A
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
•ꢀꢀCSAꢀCMHꢀ(CSA:ꢀ60˚C)
ꢀ
ꢀ
•ꢀꢀPassesꢀCSAꢀCMHꢀFlameꢀTest
PolypropyleneꢀInsulation,ꢀColorꢀCodeꢀChartꢀ#2
***A – Capacitance between conductors
***B – Capacitance between one conductor and other conductors connected to shield
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart 1
Color Code Chart 2
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
Black
Natural
Red
Black
Red
Clear
1
2
3
4
1
2
3
Green
23
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Foil Shield
ULꢀ2092,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL)ꢀCMH
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
NOM. INSULATION NOM. JACKET
NOM. CAP.*
pF/ft
polyethylene or polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
THICKNESS
THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG COND.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
A
B
Shield:
UL STYLE 2092, CM (UL) C(UL) CMH, 300V
ꢀ
ꢀ
•ꢀꢀ100%ꢀaluminum/polyesterꢀfoilꢀ“bonded”ꢀ
2
2
2
22
20
18
7/30
7/28
0.016 0.41 0.026 0.66 0.181 4.60 20.0 36.0
0.016 0.41 0.028 0.71 0.201 5.11 21.5 38.5
C2518A
C2519A
C2521A
to jacket, foil facing in
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
16/30 0.018 0.46 0.028 0.71 0.229 5.82 23.5 43.0
ꢀ
ꢀ
PolyethyleneꢀInsulation,ꢀColorꢀCodeꢀChartꢀ#1
CM (UL) c(UL) CMH, 300V
Applications:
•ꢀꢀ100%ꢀshieldedꢀcableꢀwhereꢀRFꢀshieldingꢀ
is required
•ꢀꢀControlꢀcircuits
•ꢀꢀDataꢀandꢀsignalꢀtransmission
•ꢀꢀComputerꢀinterconnections
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
2
22
7/30
0.008 0.20 0.020 0.51 0.137 3.48 28.0 50.0
C2520A
ꢀ
PolypropyleneꢀInsulation,ꢀColorꢀCodeꢀChartꢀ#2
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
ꢀ
ꢀ
Color Code Chart 1
Color Code Chart 2
NO. OF
NO. OF
Features:
•ꢀꢀTheꢀjacketꢀandꢀshieldꢀareꢀ“bonded”ꢀforꢀ
ease of removal on automatic stripping
equipment
COND.
COLOR
COND.
COLOR
ꢀ
Black
Black
Red
1
2
1
2
Natural
Compliances:
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2092ꢀ(UL:ꢀ60°C,ꢀ300V)
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
ꢀ
ꢀ
ꢀ
•ꢀꢀCSAꢀCMHꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀPassesꢀCSAꢀCMHꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
24
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Foil Shield
UL 2464, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
NOM. CAP.*
Shield:
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG COND.
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
A
B
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
4
18
19/30 0.010 0.25 0.032 0.81 0.238 6.05
47 84.5
C2543A
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Jacket:
•ꢀꢀPVC,ꢀgray
ꢀ
ꢀ
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
Applications:
Color Code Chart
ꢀ
•ꢀꢀAudio,ꢀbroadcast,ꢀinstrumentationꢀandꢀ
NO. OF
sound systems
COND.
COLOR
Black
Red
ꢀ
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
1
2
3
4
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
White
Green
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
25
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Foil Shield
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFEP
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
NOM. CAP.*
pF/ft
Separator:
•ꢀꢀPolyesterꢀtapeꢀwithꢀ25%ꢀoverlap
THICKNESS
THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG COND.
ꢀ
NUMBER COND. SIZE STRAND INCHES
mm INCHES mm INCHES mm
A
B
Shield:
3
4
18 19/30 TC 0.007
18 19/30 TC 0.007
0.18 0.014 0.36 0.178 4.27 54.0 95.0
0.18 0.014 0.36 0.185 4.70 30.0 55.0
C8106
C8114
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
withꢀ25%ꢀoverlap
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Jacket:
ꢀ
ꢀ
•ꢀꢀFEP,ꢀredꢀorꢀasꢀrequested
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+200°C
Color Code Chart
Applications:
NO. OF
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputerꢀsystems
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
COND.
COLOR
Black
White
Red
1
2
3
4
Compliances:
ꢀ
Green
•ꢀꢀNECꢀArticleꢀ800
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Features:
ꢀ
ꢀ
ꢀ
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
•ꢀꢀSuitableꢀforꢀoutdoorꢀandꢀdirectꢀburial
•ꢀꢀChemical-resistant
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
26
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Foil Shield
NEC Type CMP (UL) c(UL) and/or CL2P
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ16ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned or bare copper per ASTM B-3,
B-8 or B-33
ꢀ
•ꢀꢀClassꢀBꢀstrandingꢀperꢀASTMꢀB-8
Insulation:
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
INCHES mm INCHES mm INCHES mm
NOM. CAP.**
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
pF/ft
ꢀ
ꢀ
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
STRAND
A
B
22 AWG CONDUCTORS
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil,
2
3
4
6
22
22
22
22
7/30 TC
7/30 TC
7/30 TC
7/30 TC
0.006 0.15 0.010 0.25 0.103 2.62 51.0 92.0
0.006 0.15 0.010 0.25 0.116 2.95 45.0 81.0
0.006 0.15 0.010 0.25 0.130 3.30 45.0 81.0
0.006 0.15 0.010 0.25 0.152 3.86 40.0 73.0
C3154*
C3310*
C3155*
C3311*
withꢀ25%ꢀoverlap
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
Jacket:
•ꢀꢀFluoropolymer,ꢀnatural
ꢀ
ꢀ
ꢀ
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
•ꢀꢀSequentialꢀfootageꢀmarkedꢀtoꢀfacilitateꢀ
installations
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
•ꢀꢀIncludesꢀripcord
20 AWG CONDUCTORS
2
3
4
20
20
20
7/28 TC
0.007 0.18 0.010 0.25 0.120 3.05 53.0 96.0
0.007 0.18 0.010 0.25 0.136 3.45 46.0 84.0
C3320*
C3321*
C3322*
ꢀ
ꢀ
7/28 TC
7/28 TC
0.007
018
0.010 0.25 0.153 3.89 46.0 84.0
Applications:
18 AWG CONDUCTORS
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀIntercomꢀsystems
•ꢀꢀBackgroundꢀmusic
•ꢀꢀAudioꢀsystems
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ150ꢀvolts
2
3
18
18
18
18
18
18
18
7/26 BC
0.008 0.20 0.010 0.25 0.152 3.86 54.0 98.0
0.008 0.20 0.010 0.25 0.158 4.01 47.0 85.0
0.008 0.20 0.010 0.25 0.178 4.52 47.0 85.0
0.008 0.20 0.010 0.25 0.212 5.38 43.0 76.0
0.008 0.20 0.010 0.25 0.229 5.82 43.0 76.0
0.008 0.20 0.010 0.25 0.273 6.93 43.0 76.0
0.008 0.20 0.012 0.30 0.285 7.24 43.0 76.0
C3162
C3164
C3163
C3166
C3180
C3181
C3182
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
4
6
Compliances:
8
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀ(UL:ꢀ75°C,ꢀ150V)
•ꢀꢀNECꢀArticleꢀ800ꢀ(UL:ꢀ75°C,ꢀ300V)
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
10
12
16 AWG CONDUCTORS
Features:
2
3
4
16 19/.0117 BC 0.008 0.20 0.010 0.25 0.181 4.60 62.0 112.0
16 7/.0192 BC 0.008 0.20 0.010 0.25 0.185 4.70 52.0 93.0
16 7/.0192 BC 0.008 0.20 0.010 0.25 0.210 5.16 52.0 93.0
C3169
C3340
ꢀ
•ꢀꢀAbrasion-,ꢀchemical-ꢀandꢀwater-resistant
jacket
C3341
*CL2P only
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
**A – Capacitance between conductors
**B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart
NO. OF
COND.
COLOR
Black
White
Red
1
2
3
Green
Brown
Blue
4
5
6
Orange
Yellow
Violet
Gray
7
8
9
10
11
12
Pink
Tan
27
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Foil Shield
NEC Type CMP (UL) c(UL) and CL3P
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ16ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned or bare copper per ASTM B-3,
B-8 or B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
PVC
NOM. INSULATION NOM. JACKET
NOM. CAP.*
NOMINAL O.D. pF/ft
THICKNESS
THICKNESS
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
STRAND
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
INCHES mm INCHES mm INCHES mm
A
B
22 AWG CONDUCTORS
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
2
4
22
22
7/30 TC
0.008 0.20 0.015 0.38 0.127 3.23 51.0 91.0
C3158
C3159
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
7/30 TC
0.008 0.20 0.015 0.38 0.146 3.71 45.0 81.0
18 AWG CONDUCTORS
Jacket:
2
4
18
18
18
18
18
18
18
18
Solid BC
0.008 0.20 0.015 0.38 0.148 3.76 67.0 120.0
0.008 0.20 0.015 0.38 0.171 4.34 58.0 104.0
0.008 0.20 0.015 0.38 0.164 4.17 61.0 110.0
0.008 0.20 0.015 0.38 0.169 4.29 53.0 96.0
0.008 0.20 0.015 0.38 0.185 4.70 53.0 96.0
0.010 0.25 0.015 0.38 0.230 5.84 48.0 86.0
0.012 0.20 0.015 0.38 0.310 7.87 47.0 84.0
0.010 0.25 0.015 0.38 0.308 7.82 52.5 94.6
C3060
C3061
C3062
C3064
C3063
C3065
C3183
C3184
ꢀ
ꢀ
ꢀ
•ꢀFꢀ lexguard®ꢀPVC,ꢀnatural
•ꢀꢀTemperatureꢀrange:ꢀ0°Cꢀtoꢀ+75°C
Solid BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
•ꢀꢀSequentialꢀfootageꢀmarkedꢀtoꢀfacilitateꢀ
installation
•ꢀꢀIncludesꢀripcord
2
3
ꢀ
Applications:
•ꢀꢀIntercomꢀsystems
•ꢀꢀBackgroundꢀmusic
•ꢀꢀAudioꢀsystems
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ150ꢀvolts
4
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
6
10
12
16 AWG CONDUCTORS
Compliances:
2
16 19/.0117 BC 0.009 0.23 0.015 0.38 0.187 4.75 75.0 134.0
C3068
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀ(UL:ꢀ75°C,ꢀ150V)
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
•ꢀꢀNECꢀArticleꢀ800ꢀ(UL:ꢀ75°C,ꢀ300V)
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Color Code Chart
Features:
NO. OF
COND.
COLOR
Black
White
Red
ꢀ
•ꢀꢀFlexible
ꢀ
•ꢀꢀEasyꢀtoꢀterminate
1
2
3
4
5
6
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Green
Brown
Blue
Orange
Yellow
Violet
Gray
7
8
9
10
11
12
Pink
Tan
28
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Foil Shield
VariousꢀAWMꢀStyles,ꢀCSAꢀTypeꢀAWMꢀI/IIꢀA/B, NEC/CEC Type CMG (CSA C/US),
NEC Type CL2
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀorꢀ
stranded tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
pF/ft
NOMINAL O.D.
polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
CATALOG NO. OF AWG COND.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
A
B
Shield:
AWM STYLE 20251, CSA TYPE AWM, CSA C/US TYPE CMG
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
2
2
2
2
3
3
3
3
4
4
24
22
20
18
22
20
20
18
22
20
7/32
7/30
7/28
16/30
7/30
7/28
7/28
16/30
7/30
7/28
0.016 0.41 0.026 0.66 0.167 4.24 23.0 42.0
C4152A
C4153A
C4154A
C4155A
C4156A
C4157A
C4158A
C4159A
C4160A
C4161A
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
0.016 0.41 0.026 0.66 0.179 4.55 21.0 38.0
0.016 0.41 0.030 0.76 0.203 5.16 22.0 40.0
0.018 0.46 0.030 0.76 0.233 5.92 24.0 43.0
0.016 0.41 0.030 0.76 0.196 4.98 25.0 45.0
0.016 0.41 0.030 0.76 0.210 5.33 27.0 51.0
0.016 0.41 0.030 0.76 0.213 5.41 29.0 52.0
0.018 0.46 0.030 0.76 0.247 6.27 22.0 40.0
0.016 0.41 0.030 0.76 0.213 5.41 23.0 42.0
0.016 0.41 0.030 0.76 0.234 5.94 26.0 74.0
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
ꢀ
ꢀ
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀRecordingꢀstudiosꢀandꢀsoundꢀstages
•ꢀꢀBroadcastꢀandꢀsoundꢀsystems
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipmentꢀcontrol
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀorꢀ600ꢀ
volts
ColorꢀCodeꢀChartꢀ#1
Features:
AWM STYLE 2106, CSA TYPE AWM, CSA C/US TYPE CMG
ꢀ
ꢀ
ꢀ
•ꢀꢀExcellentꢀelectricalꢀproperties
•ꢀꢀSuperiorꢀshieldingꢀeffectivenessꢀ
•ꢀꢀ25%ꢀshieldꢀoverlapꢀprovidesꢀexcellentꢀ
shielding efficiency
2
16 19/.0117 0.032 0.81 0.032 0.81 0.307 7.80 27.0 49.0
16 19/.0117 0.032 0.81 0.032 0.81 0.326 8.28 26.0 46.0
C4162A
C4165A
3
ColorꢀCodeꢀChartꢀ#1
ꢀ
•ꢀꢀGoodꢀflexibility
NEC TYPE CL2, AWM STYLE 2464, CSA TYPE AWM
Compliances:
•ꢀꢀAWMꢀStyleꢀ20251ꢀ(CSA:ꢀ60˚C,ꢀ150V,ꢀ
300Vꢀpeak)
2
14
41/30
0.020 0.51 0.032 0.81 0.298 7.57 31.0 56.0
C4163A
ꢀ
ColorꢀCodeꢀChartꢀ#3
ꢀ
ꢀ
•ꢀꢀCSAꢀTypeꢀAWMꢀ(80˚C,ꢀ600V)
•ꢀꢀCSAꢀCertifiedꢀCMGꢀtoꢀharmonizedꢀ
standard UL444 and CSA 22.2 No. 214
•ꢀꢀNECꢀTypeꢀCL2/CECꢀTypeꢀCMGꢀ(CSA:ꢀ
80˚C,ꢀ300V)
NEC TYPE CL2, AWM STYLE 2106, CSA TYPE AWM
2
12 19/.0185 0.032 0.81 0.040 1.02 0.390 9.90 35.0 63.0
C4164A
ColorꢀCodeꢀChartꢀ#1
ꢀ
AWM STYLE 20251, CSA TYPE AWM, CSA C/US TYPE CMG
ꢀ
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀCSAꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
2
2
3
22
22
22
Solid
7/30
7/30
0.007 0.18 0.020 0.51 0.124 3.15 40.0 76.0
0.008 0.20 0.020 0.51 0.137 3.48 34.0 67.0
0.008 0.20 0.020 0.51 0.144 3.66 32.0 60.0
C4167A
C4168A
C4169A
ꢀ
•ꢀꢀPassesꢀCSAꢀFT4ꢀVerticalꢀFlameꢀTest
PolyethyleneꢀInsulation,ꢀColorꢀCodeꢀChartꢀ#2
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart 1
Color Code Chart 2
Color Code Chart 3
NO. OF
COND.
NO. OF
NO. OF
COLOR
Black
COND.
COLOR
COND.
COLOR
Black
Red
Black
White
1
2
3
4
1
2
3
1
2
Natural
Red
Clear
Green
29
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Foil Shield
AWM Styles 2464, CSA Type AWMꢀI/IIꢀA/B, NEC/CEC Type CMG (CSA C/US),
or NEC Type CL2
Product Construction:
Conductor:
•ꢀ2ꢀ 2ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
NOM.
INSULATION NOM. JACKET
NOM. CAP.*
pF/ft
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
THICKNESS
THICKNESS NOMINAL O.D.
CATALOG NO. OF AWG COND.
NUMBER COND. SIZE STRAND
COLOR
CODE
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
INCHES mm INCHES mm INCHES mm
A
B
Shield:
AWM STYLE 2464, CSA TYPE AWM, CSA C/US TYPE CMG
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
2
2
3
4
6
8
2
2
3
4
2
2
3
4
6
2
2
3
22
22
22
22
22
22
20
20
20
20
18
18
18
18
18
7/30
7/30
0.009 0.23 0.030 0.76 0.165 4.19
0.009 0.23 0.032 0.81 0.165 4.19
0.009 0.23 0.030 0.76 0.169 4.29
0.009 0.23 0.030 0.76 0.181 4.60
0.009 0.23 0.032 0.81 0.204 5.18
0.009 0.23 0.032 0.81 0.223 5.66
0.012 0.30 0.030 0.76 0.187 4.75
0.012 0.30 0.032 0.81 0.191 4.85
0.012 0.30 0.030 0.76 0.200 5.08
0.012 0.30 0.030 0.76 0.216 5.49
0.012 0.30 0.030 0.76 0.203 5.16
0.012 0.30 0.032 0.81 0.205 5.20
0.012 0.30 0.030 0.76 0.214 5.44
0.012 0.30 0.032 0.81 0.236 5.99
0.012 0.30 0.032 0.81 0.271 6.88
1
2
2
2
2
2
1
2
2
2
1
2
2
2
2
1
2
2
47.0 85.0
47.0 85.0
43.0 76.0
43.0 76.0
43.0 76.0
43.0 76.0
46.0 83.0
46.0 83.0
42.0 75.0
42.0 75.0
51.0 92.0
51.0 92.0
46.0 83.0
46.0 83.0
46.0 83.0
62.0 112.0
62.0 112.0
58.0 104.0
C4192A
C4210A
C4193A
C4194A
C4207A
C4208A
C4166A
C4211A
C4195A
C4196A
C4197A
C4212A
C4198A
C4204A
C4205A
C4199A
C4213A
C4200A
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+105°C
7/30
ꢀ
ꢀ
7/30
7/30
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀRecordingꢀstudiosꢀandꢀsoundꢀstages
•ꢀꢀBroadcastꢀandꢀsoundꢀsystems
•ꢀꢀIndustrialꢀequipmentꢀcontrol
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀorꢀ600ꢀ
7/30
7/28
7/28
7/28
volts
7/28
Features:
•ꢀꢀSuperiorꢀshieldingꢀeffectivenessꢀ
•ꢀꢀ25%ꢀshieldꢀoverlapꢀprovidesꢀexcellentꢀ
shielding efficiency
16/30
16/30
16/30
16/30
16/30
ꢀ
ꢀ
ꢀ
•ꢀꢀGoodꢀflexibility
Compliances:
•ꢀꢀAWMꢀStyleꢀ2464ꢀ(ULꢀorꢀCSA:ꢀ80˚C,ꢀ
300V)
•ꢀꢀCSAꢀTypeꢀAWMꢀ(105˚C,ꢀ600V)
•ꢀꢀCSAꢀCertifiedꢀCMGꢀtoꢀharmonizedꢀ
standard UL444 and CSA 22.2 No. 214
•ꢀꢀNEC/CECꢀTypeꢀCMGꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀCSAꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
•ꢀꢀPassesꢀCSAꢀFT4ꢀVerticalꢀFlameꢀTest
•ꢀꢀULꢀCertifiedꢀCL2ꢀtoꢀStandardꢀULꢀ13*
ꢀ
16 19/.0117 0.010 0.25 0.030 0.76 0.218 5.54
16 19/.0117 0.010 0.25 0.032 0.81 0.219 5.56
16 19/.0117 0.010 0.25 0.030 0.76 0.230 5.84
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
AWM STYLE 2464, CSA TYPE AWM (FT4), NEC TYPE CL2*
2
2
2
14 19/.0147 0.014 0.36 0.030 0.76 0.268 6.81
14 19/.0147 0.014 0.36 0.030 0.76 0.268 6.81
12 19/.0185 0.014 0.36 0.030 0.76 0.302 7.67
1
2
1
60.0 107.0
60.0 107.0
64.0 116.0
C4201A
C4215A
C4202A
ꢀ
ꢀ
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart 1
Color Code Chart 2
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
Black
Red
Black
White
Red
1
2
1
2
3
4
5
6
7
8
Green
Brown
Blue
Orange
Yellow
30
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Foil Shield
AWMꢀStyleꢀ2464,ꢀCSAꢀTypeꢀAWMꢀI/IIꢀA/B,ꢀNEC/CECꢀTypeꢀCMGꢀ(CSAꢀC/US)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
NOMINAL
INSULATION
THICKNESS
NOMINAL
JACKET
NOMINAL DCR NOMINAL
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVCꢀ
NOMINAL
O.D.
Ω/kft
CAP.*
pF/ft
NO.
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
THICKNESS
@20˚C
CATALOG OF AWG COND.
Shield:
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
A
B
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester
AWM STYLE 2464, CSA TYPE AWM, CSA C/US TYPE CMG
withꢀ25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
2
24
24
24
24
24
24
24
24
24
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
0.010 0.25 0.032 0.81 0.157
0.010 0.25 0.032 0.81 0.164
0.010 0.25 0.032 0.81 0.175
0.010 0.25 0.032 0.81 0.188
0.010 0.25 0.032 0.81 0.201
0.010 0.25 0.032 0.81 0.201
0.010 0.25 0.032 0.81 0.215
0.010 0.25 0.032 0.81 0.228
0.010 0.25 0.032 0.81 0.245
3.99 26.0 18.0 40.0 72.0
4.17 26.0 18.0 36.0 66.0
4.45 26.0 18.0 36.0 66.0
4.78 26.0 16.0 36.0 66.0
5.11 26.0 16.0 34.0 61.0
5.11 26.0 16.0 34.0 61.0
5.46 26.0 16.0 34.0 61.0
5.79 26.0 16.0 34.0 61.0
6.22 26.0 14.0 34.0 61.0
C4216A
C4217A
C4218A
C4219A
C4220A
C4221A
C4222A
C4223A
C4224A
3
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+105˚C
4
5
ꢀ
ꢀ
6
7
Applications:
•ꢀꢀComputerꢀinterconnections
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀIndustrialꢀequipmentꢀcontrol
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀorꢀ600ꢀ
8
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
9
10
ColorꢀCodeꢀChartꢀ#1
15
20
25
30
40
50
24
24
24
24
24
24
7/32
7/32
7/32
7/32
7/32
7/32
0.010 0.25 0.032 0.81 0.276
0.010 0.25 0.032 0.81 0.303
0.010 0.25 0.032 0.81 0.333
0.010 0.25 0.032 0.81 0.351
0.010 0.25 0.032 0.81 0.391
7.01 26.0 14.0 34.0 61.0
7.70 26.0 14.0 34.0 61.0
8.46 26.0 12.0 34.0 61.0
8.92 26.0 12.0 34.0 61.0
9.93 26.0 12.0 34.0 61.0
C4225A
C4226A
C4227A
C4228A
C4229A
C4230A
volts
Features:
•ꢀꢀSuperiorꢀshieldingꢀeffectivenessꢀ
•ꢀꢀ25%ꢀshieldꢀoverlapꢀprovidesꢀexcellentꢀ
shielding efficiency
0.010 0.25 0.032 0.81 0.439 11.15 26.0 10.0 34.0 61.0
ꢀ
ꢀ
ColorꢀCodeꢀChartꢀ#2
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
•ꢀꢀGoodꢀflexibility
Color Code Chart 1 – For cables up to and including 10 conductors
Compliances:
•ꢀꢀAWMꢀStyleꢀ2464ꢀ(ULꢀorꢀCSA:ꢀ80˚C,ꢀ
300V)
ꢀ
NO. OF
COND.
NO. OF
COND.
COLOR
Black
White
Red
Green
Brown
COLOR
Blue
Orange
Yellow
Violet
Gray
ꢀ
ꢀ
•ꢀꢀCSAꢀTypeꢀAWMꢀ(105˚C,ꢀ600V)
•ꢀꢀCSAꢀCertifiedꢀCMGꢀtoꢀharmonizedꢀ
standard UL444 and CSA 22.2 No. 214
1
2
3
4
5
6
7
8
9
10
ꢀ
ꢀ
ꢀ
•ꢀꢀNEC/CECꢀTypeꢀCMGꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀCSAꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Color Code Chart 2 Per ICEA – For cables of 15 to 50 conductors
ꢀ
•ꢀꢀPassesꢀCSAꢀFT4ꢀVerticalꢀFlameꢀTest
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
Packaging:
COLOR
Black
White
Red
Green
COLOR
Orange/Red
Blue/Red
Red/Green
COLOR
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
White/Red/Orange
Orange/White/Blue
White/Red/Blue
Black/White/Green
White/Black/Green
Red/White/Green
Green/White/Blue
Orange/Red/Green
Blue/Red/Green
Black/White/Blue
White/Black/Blue
Red/White/Blue
Green/Orange/Red
Orange/Red/Blue
Blue/Red/Orange
Black/Orange/Red
1
2
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
3
Orange/Green
4
Orange
Blue
Black/White/Red
White/Black/Red
Red/Black/White
Green/Black/White
Orange/Black/White
Blue/Black/White
Black/Red/Green
White/Red/Green
Red/Black/Green
Green/Black/Orange
Orange/Black/Green
Blue/White/Orange
Black/White/Orange
5
6
White/Black
Red/Black
Green/Black
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
Black/Red
White/Red
7
8
9
10
11
12
13
14
15
16
17
31
Electronics
Communication & Control Cable, Multi-Conductor
Power-Limited Tray Cable, Foil Shield
NEC Type PLTC
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
pF/ft
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
CATALOG NO. OF AWG COND.
A
B
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
2
3
2
3
2
3
2
3
2
3
2
22
22
20
20
18
18
7/30
7/30
0.013 0.33 0.037 0.94 0.191 4.85 43.0 77.5
0.013 0.33 0.037 0.94 0.199 5.05 39.5 71.0
0.013 0.33 0.037 0.94 0.207 5.26 50.0 89.5
0.013 0.33 0.037 0.94 0.217 5.51 45.0 81.0
0.015 0.38 0.037 0.94 0.227 5.77 51.5 92.5
0.015 0.38 0.037 0.94 0.238 6.04 46.5 83.5
C0450A
C0451A
C0452A
C0453A
C0454A
C0455A
C0456A
C0457A
C0458A
C0459A
C0460A
25%ꢀoverlapꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
Jacket:
7/28
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
7/28
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+105˚C
16/30
16/30
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀCableꢀtrayꢀinstallations
•ꢀꢀPowerꢀlimitedꢀcircuits
•ꢀꢀIntercomꢀsystems
•ꢀꢀBusinessꢀmachines
•ꢀꢀCashꢀregisters
•ꢀꢀIndustrialꢀcontrolꢀsystems
•ꢀꢀPetrochemicalꢀrefineries
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
•ꢀꢀBurglarꢀalarms
16 19/.0117 0.013 0.33 0.037 0.94 0.243 6.17 64.0 115.5
16 19/.0117 0.013 0.33 0.037 0.94 0.255 6.48 56.5 102.0
14 19/.0147 0.013 0.33 0.042 1.07 0.288 7.32 72.5 131.0
14 19/.0147 0.015 0.33 0.042 1.07 0.298 7.57 60.0 108.0
12 19/.0185 0.013 0.33 0.042 1.07 0.315 8.00 80.5 145.0
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Features:
ꢀ
ꢀ
ꢀ
•ꢀꢀSunlight-resistantꢀPVCꢀjacket
•ꢀꢀGoodꢀweatherꢀresistance
•ꢀꢀULꢀtrayꢀcableꢀrated
Color Code Chart
NO. OF
COND.
COLOR
Black
Red
Compliances:
ꢀ
1
2
3
•ꢀꢀNECꢀArticleꢀ725ꢀPower-LimitedꢀTrayꢀ
Cableꢀ(UL:ꢀ105°C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
ꢀ
ꢀ
White
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
32
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Spiral Shield
UL 2095, NEC Type CL2 and CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ16ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
NOM. CAP.*
NOMINAL O.D.
pF/ft
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
CATALOG NO. OF AWG
COND.
A
B
Shield:
•ꢀꢀ85%ꢀspiralꢀtinnedꢀcopper
UL STYLE 2095, CM (UL) c(UL), CSA CMG, 300V
ꢀ
2
2
22
20
7/30
7/28
0.015 0.38 0.032 0.81 0.197 5.00 40.0 72.0
0.016 0.41 0.032 0.81 0.215 5.46 44.0 80.2
C2882A
C2888A
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
ColorꢀCodeꢀChartꢀ#1
CL2/CM (UL) c(UL), CSA CMG, 300V
Applications:
ꢀ
•ꢀꢀElectronicꢀcircuitsꢀwhereꢀRFꢀshieldingꢀ
3
4
6
3
22
22
22
18
7/30
7/30
7/30
7/26
0.015 0.38 0.032 0.81 0.206 5.23 37.0 67.0
0.015 0.38 0.032 0.81 0.222 5.64 37.0 67.0
0.015 0.38 0.032 0.81 0.257 6.53 34.5 62.0
0.020 0.51 0.032 0.81 0.266 6.76 41.0 74.0
C1335A
C1337A
C1341A
C2768A
is required
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀRadioꢀtransmitters
•ꢀꢀSoundꢀsystems
•ꢀꢀRecordingꢀstudios
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ColorꢀCodeꢀChartꢀ#1
Features:
•ꢀꢀSpiralꢀshieldꢀallowsꢀeaseꢀofꢀ“pigtailꢀ
soldering”
CM (UL) c(UL), CSA CMG, 300V
ꢀ
2
2
18
16/30
0.016 0.41 0.032 0.81 0.252 6.40 49.5 89.0
C2892A
C2895A
16 19/.0117 0.016 0.41 0.032 0.81 0.265 6.73 58.0 104.0
ꢀ
•ꢀꢀMaximumꢀflexibility
ColorꢀCodeꢀChartꢀ#2
*A – Capacitance between conductors
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2095ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
*B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart 1
Color Code Chart 2
NO. OF
COND.
CATALOG
NUMBER
COLOR
CONDUCTOR
COLOR
ꢀ
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL2ꢀ(UL:ꢀ75°C)
Black
Red
1
2
3
4
5
6
1
2
White
Red
C2892A
Packaging:
ꢀ
1
2
White
Black
White
Green
Yellow
Blue
C2895A
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
33
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Braid Shield
NEC Type CL2 and CM(UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀsolidꢀorꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
NOM. INSULATION NOM. JACKET
NOM. CAP.*
pF/ft
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
THICKNESS
THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG COND.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
A
B
Shield:
ꢀ
ꢀ
•ꢀꢀ88%ꢀtinnedꢀcopperꢀbraid
2
2
22
22
Solid
7/30
0.015 0.38 0.032 0.81 0.209 5.31 38.6 69.4
0.015 0.38 0.032 0.81 0.211 5.36 39.3 70.7
C2676A
C2677A
•ꢀꢀStrandedꢀorꢀsolidꢀtinnedꢀcopperꢀdrainꢀ
wire
*A – Capacitance between conductors*
*B – Capacitance between one conductor and other conductors connected to shield
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀblack
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
Applications:
Color Code Chart
ꢀ
•ꢀꢀElectronicꢀcircuitsꢀwhereꢀRFꢀshieldingꢀ
NO. OF
is required
COND.
COLOR
Black
Red
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀRadioꢀtransmitters
•ꢀꢀSoundꢀsystems
•ꢀꢀRecordingꢀstudios
•ꢀꢀGoodꢀflexibility
•ꢀꢀExcellentꢀshieldingꢀforꢀnoiseꢀreduction
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
1
2
Compliances:
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL2ꢀ(UL:ꢀ75°C)
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
34
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Braid Shield
ULꢀ2092,ꢀ2093,ꢀ2094,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL)ꢀCMH
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polyethylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
NOM. CAP.*
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG COND.
Shield:
A
B
ꢀ
ꢀ
•ꢀꢀ80%ꢀtinnedꢀcopperꢀbraidꢀ
AWM STYLE 2092, CM (UL) c(UL) CMH, 300V
•ꢀꢀMylarꢀwrapꢀunderꢀbraid
2
3
20
26/34 0.016 0.38 0.029 0.74 0.226 5.74 24.0 43.0
C1642A
C1643A
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
AWM STYLE 2093, CM (UL) c(UL) CMH, 300V
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
20
26/34 0.016 0.38 0.029 0.74 0.236 5.99 22.0 40.0
Applications:
ꢀ
•ꢀꢀElectronicꢀcircuitsꢀwhereꢀRFꢀshieldingꢀ
is required
•ꢀꢀVideoꢀinterconnect
•ꢀꢀBroadcastꢀandꢀstudio
•ꢀꢀSoundꢀsystems
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
AWM STYLE 2094, CM (UL) c(UL) CMH 300V
ꢀ
ꢀ
ꢀ
ꢀ
4
5
6
20
26/34 0.016 0.38 0.029 0.74 0.255 6.48 22.0 39.0
26/34 0.016 0.38 0.029 0.74 0.274 6.96 22.0 39.0
26/34 0.016 0.38 0.029 0.74 0.290 7.37 20.0 36.0
C1644A
C1645A
C1646A
20
20
Features:
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
ꢀ
•ꢀꢀLowꢀcapacitance
•ꢀꢀLightweight
•ꢀꢀExcellentꢀshieldingꢀforꢀnoiseꢀreduction
Color Code Chart
Compliances:
NO. OF
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCM/CMHꢀ
(UL:ꢀ75°C)
COND.
COLOR
Black
White
Red
1
2
3
4
5
6
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀAWMꢀstyleꢀ2092ꢀ(UL:ꢀ60˚C,ꢀ300V)
•ꢀꢀAWMꢀstyleꢀ2093ꢀ(UL:ꢀ60˚C,ꢀ300V)
•ꢀꢀAWMꢀstyleꢀ2094ꢀ(UL:ꢀ60˚C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀVW-1ꢀVerticalꢀWireꢀ
Flame Test
Green
Yellow
Blue
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
35
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Braid Shield
UL 2095, NEC Type CM (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ16ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
NOM. INSULATION NOM. JACKET
NOM. CAP.*
pF/ft
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
THICKNESS
THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG COND.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
A
B
Shield:
•ꢀꢀ75%ꢀtinnedꢀcopperꢀbraid
ꢀ
2
3
4
2
3
4
2
3
4
2
22
22
22
20
20
20
18
18
18
16
7/30
7/30
7/30
7/28
7/28
7/28
0.015 0.38 0.032 0.81 0.212 5.38 40.0 72.0
C2679A
C2678A
C2680A
C2681A
C1332A
C2683A
C2686A
C2687A
C2688A
C2689A
Jacket:
0.015 0.38 0.032 0.81 0.221 5.61 37.0 67.0
0.015 0.38 0.032 0.81 0.237 6.02 37.0 67.0
0.016 0.41 0.032 0.81 0.230 5.84 44.0 80.0
0.016 0.41 0.032 0.81 0.240 6.10 40.0 72.0
0.016 0.41 0.032 0.81 0.259 6.58 40.0 73.0
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
Applications:
•ꢀꢀElectronicꢀcircuitsꢀwhereꢀRFꢀshieldingꢀ
is required
•ꢀꢀRadioꢀtransmitters
•ꢀꢀSoundꢀsystems
•ꢀꢀRecordingꢀstudios
•ꢀꢀProvidesꢀgoodꢀflexibility
•ꢀꢀExcellentꢀshieldingꢀforꢀnoiseꢀreduction
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
16/30 0.016 0.41 0.032 0.81 0.252 6.40 49.0 89.0
16/30 0.016 0.41 0.032 0.81 0.264 6.71 45.0 80.5
16/30 0.016 0.41 0.032 0.81 0.286 7.26 45.0 80.5
19/29 0.020 0.51 0.030 0.76 0.280 7.11 51.0 91.0
Compliances:
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2095ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Color Code Chart
NO. OF
COND.
COLOR
Black
Red
ꢀ
ꢀ
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
1
2
3
4
Packaging:
White
Green
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
36
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Braid Shield
MIL-W-16878ꢀTypeꢀB
Product Construction:
Conductor:
ꢀ
•ꢀꢀ28ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVCꢀperꢀ
MIL-W-16878ꢀTypeꢀB
ꢀ
ꢀ
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
NOM. CAP.*
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG COND.
Shield:
•ꢀꢀ90%ꢀtinnedꢀcopperꢀbraid
A
B
ꢀ
2
3
28
28
28
28
28
28
28
28
28
7/36
7/36
7/36
7/36
7/36
7/36
7/36
7/36
7/36
0.010 0.28 0.016 0.41 0.130 3.30 34.0 61.0
0.010 0.28 0.016 0.41 0.135 3.30 32.5 58.5
0.010 0.28 0.016 0.41 0.145 3.68 32.5 58.5
0.010 0.28 0.019 0.48 0.172 4.37 30.5 55.0
0.010 0.28 0.021 0.53 0.187 4.75 30.5 55.0
0.010 0.28 0.021 0.53 0.212 5.38 30.5 55.0
0.010 0.28 0.021 0.53 0.217 5.51 30.5 55.0
0.010 0.28 0.021 0.53 0.237 6.01 30.5 55.0
0.010 0.28 0.021 0.53 0.259 6.58 30.5 55.0
C6500A
C6501A
C6502A
C6503A
C6504A
C6505A
C6506A
C6507A
C6508A
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+90°C
4
Applications:
•ꢀꢀElectronicꢀcircuitsꢀwhereꢀRFꢀshieldingꢀ
is required
•ꢀꢀRemoteꢀcontrolꢀforꢀstudioꢀequipment
•ꢀꢀSoundꢀsystems
6
ꢀ
8
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
10
12
15
20
•ꢀꢀProvidesꢀgoodꢀflexibility
•ꢀꢀExcellentꢀshieldingꢀforꢀnoiseꢀreduction
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ600ꢀvolts
•ꢀꢀNonꢀQPL
*A – Capacitance between conductors
Compliances:
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Packaging:
Color Code Chart
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
packaging and color options
COLOR
Black
COLOR
Red/Black
COLOR
Blue/White
Black/Red
White/Red
Orange/Red
Blue/Red
1
2
3
4
5
6
7
8
9
15
16
17
18
19
20
White
Green/Black
Orange/Black
Blue/Black
Black/White
Red/White
Red
10
11
12
13
14
Green
Orange
Blue
Red/Green
White/Black
Green/White
37
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Foil/Braid Shield
UL 2094, NEC Type CL2
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
NOM. INSULATION NOM. JACKET
NOM. CAP.*
pF/ft
polyethylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
THICKNESS
THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG COND.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
A
B
Shield:
8
20
26/34 0.016 0.38 0.029 0.74 0.316 8.03 20.0 36.0
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
C1648A
ꢀ
ꢀ
25%ꢀoverlap,ꢀfoilꢀfacingꢀoutꢀ
•ꢀꢀ80%ꢀtinnedꢀcopperꢀbraid
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
Color Code Chart
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
NO. OF
COND.
NO. OF
COND.
Applications:
COLOR
Black
White
Red
COLOR
Yellow
Blue
ꢀ
•ꢀꢀElectronicꢀcircuitsꢀwhereꢀRFꢀshieldingꢀ
1
2
3
4
5
6
7
8
is required
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀVideoꢀinterconnect
•ꢀꢀBroadcastꢀandꢀstudio
•ꢀꢀSoundꢀsystems
Brown
Orange
Green
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Features:
ꢀ
ꢀ
ꢀ
•ꢀꢀLowꢀcapacitance
•ꢀꢀLightweight
•ꢀꢀExcellentꢀshieldingꢀforꢀnoiseꢀreduction
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL2ꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2094ꢀ(UL:ꢀ60°C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
38
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Foil & TC Braid Shield
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀFullyꢀannealedꢀstrandedꢀtinnedꢀcopperꢀ
per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFEP
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
mm INCHES mm INCHES mm
NOM. CAP.*
Separator:
•ꢀꢀPolyesterꢀtapeꢀwithꢀ25%ꢀoverlap
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG COND.
ꢀ
NUMBER COND. SIZE STRAND INCHES
A
B
Shield:
16 AWG CONDUCTORS
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
6
3
2
16
16
16
19/29
19/29
19/29
0.007
0.007
0.007
0.18 0.014 0.36 0.270 6.86 33.0 61.0
0.18 0.014 0.36 0.209 5.31 35.0 63.0
0.18 0.014 0.36 0.198 5.03 35.0 63.0
C8108
C8119
C8111
withꢀ25%ꢀoverlap
•ꢀꢀTinnedꢀcopperꢀbraid,ꢀ90%ꢀcoverage
Jacket:
•ꢀꢀFEP,ꢀredꢀorꢀasꢀrequested
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+200°C
ꢀ
ꢀ
18 AWG CONDUCTORS
6
4
3
18
18
18
19/30
19/30
19/30
0.007
0.007
0.007
0.18 0.014 0.36 0.242 6.15 33.0 61.0
C8120
C8110
C8107
Applications:
•ꢀꢀComputerꢀsystems
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀAudioꢀcontrols
0.18 0.014 0.36 0.206 5.23 35.0 63.0
0.18 0.014 0.36 0.190 4.83 35.0 63.0
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
24 AWG CONDUCTORS
3
24
7/32
0.006
0.15 0.014 0.36 0.133 3.38 25.0 45.0
C8115
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
*A – Capacitance between conductors
Compliances:
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
•ꢀꢀNECꢀArticleꢀ800
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Color Code Chart
NO. OF
Features:
COND.
COLOR
Black
White
Red
ꢀ
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
1
2
3
4
5
6
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Green
Orange
Blue
39
Electronics
Communication & Control Cable, Multi-Conductor
Multi-Conductor, Rubber, Braid Shield
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀrubber
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
Shield:
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
ꢀ
•ꢀꢀ80%ꢀtinnedꢀcopperꢀbraid
NUMBER COND. SIZE STRAND INCHES
mm
INCHES
mm
INCHES
mm
Jacket:
•ꢀꢀRubber,ꢀblack
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+60°C
2
3
4
5
6
7
8
20
20
20
20
20
20
20
26/34
26/34
26/34
26/34
26/34
26/34
26/34
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.035
0.035
0.035
0.035
0.035
0.035
0.035
0.89
0.89
0.89
0.89
0.89
0.89
0.89
0.270
0.285
0.300
0.330
0.340
0.355
0.385
6.86
7.24
7.62
8.38
8.64
9.02
9.78
C1302
C1304
C1305
C1308
C1310
C1312
C1313
ꢀ
ꢀ
Applications:
•ꢀꢀControlꢀcircuits
•ꢀꢀBroadcastꢀandꢀstudioꢀapplications
•ꢀꢀAudioꢀinterconnects
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
Features:
•ꢀꢀImpact-ꢀandꢀabrasion-resistant
ꢀ
ꢀ
•ꢀꢀStrandedꢀconductorsꢀforꢀsuperiorꢀ
flexibility
Color Code Chart
Compliances:
NO. OF
COND.
NO. OF
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
COLOR
COND.
COLOR
Packaging:
Black
White
Red
Blue
1
2
3
4
5
6
7
8
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Brown
Yellow
Orange
Green
40
Communication & Control Cable, Multi-Conductor
Electronics
Multi-Conductor, Carolprene®, Braid Shield
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀthruꢀ14ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀrubber
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
Shield:
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
ꢀ
•ꢀꢀ80%ꢀtinnedꢀcopperꢀbraid
NUMBER COND. SIZE STRAND INCHES
mm
INCHES
mm
INCHES
mm
Jacket:
2
3
18
18
18
18
18
18
18
16
16
16
16
16
14
14
41/34
41/34
41/34
41/34
41/34
41/34
41/34
65/34
65/34
65/34
65/34
65/34
41/30
41/30
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.025
0.025
0.025
0.025
0.025
0.030
0.030
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.64
0.64
0.64
0.64
0.64
0.76
0.76
0.035
0.035
0.035
0.035
0.035
0.035
0.065
0.035
0.035
0.035
0.040
0.040
0.040
0.040
0.89
0.89
0.89
0.89
0.89
0.89
1.65
0.89
0.89
0.89
1.02
1.02
1.02
1.02
0.295
0.305
0.330
0.370
0.420
0.425
0.555
0.335
0.355
0.385
0.445
0.510
0.395
0.455
7.49
7.75
C1202
C1203
C1204
C1206
C1208
C1210
C1212
C1602
C1603
C1604
C1606
C1608
C1612
C1614
ꢀ
ꢀ
•ꢀꢀCarolprene®, black
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+60°C
Applications:
•ꢀꢀControlꢀcircuits
•ꢀꢀBroadcastꢀandꢀstudioꢀapplications
•ꢀꢀAudioꢀinterconnects
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
4
8.38
ꢀ
ꢀ
ꢀ
ꢀ
6
9.39
8
10.67
10.80
14.10
8.51
10
12
2
Features:
•ꢀꢀImpact-ꢀandꢀabrasion-resistant
•ꢀꢀStrandedꢀconductorsꢀforꢀsuperiorꢀ
flexibility
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀVW-1ꢀVerticalꢀWireꢀ
Flame Test
ꢀ
ꢀ
3
9.02
ꢀ
4
9.78
6
11.30
12.95
10.03
11.56
Compliance:
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
ꢀ
8
Packaging:
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
2
ꢀ
4
packaging and color options
Color Code Chart
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
Black
White
Red
Yellow
Orange
Gray
1
2
3
4
5
6
7
8
9
10
11
12
Green
Blue
Violet
White/Black
White/Red
Brown
41
Electronics
Communication & Control Cable, Multi-Paired
3
Index
Page
Multi-Paired,
Unshielded
43-45
Multi-Paired,
Foil Shield
46-52
53-54
55
Multi-Paired,
Foil Shield (CSA)
Multi-Paired,
Foil Shield, Mid-Cap
Multi-Paired,
Foil Shield, Lo-Cap®
56
Multi-Paired, Overall Foil & TC
Braid Shield, Lo-Cap®
57
In many electronic applications, Circuit separation is further
two wires are required to
complete circuits; these are
often referred to as “balanced
arrays” or “twisted pair”
constructions.
enhanced in those designs
employing individual circuit
shields in concert with an
overall shield. These shielding
systems are available from
General Cable in myriad
Multi-Paired,
Individually Shielded
58
Multi-Paired,
Individually Shielded (CSA)
59
Paired cable designs find
frequent application in
combinations to suit the unique
needs of the circuit designer.
Multi-Paired, Individually
Shielded, Overall Shield
60
circuits requiring circuit-to-
circuit isolation from noise,
minimization of capacitance
imbalances and a reduction of
EMI interference currents.
As with the multi-conductor
designs, a wide array of
insulating and jacketing
materials are available to meet
specific electronic applications.
Multi-Paired,
Individually Foil Shielded
61-64
65
Power-Limited Tray Cable,
Individually Shielded
General Cable’s Carol® Brand
communication cable products
are manufactured to meet
Power-Limited Tray Cable,
Foil Shield or Foil/Braid Shield
66
the latest UL, CSA and NEC
requirements and approvals.
42
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Unshielded
UL 2464, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀsolidꢀorꢀstrandedꢀ
tinned copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
NOM.
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL O.D.
C-C
CAP.*
pF/ft
Applications:
CATALOG NO. OF AWG
COND.
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
NUMBER PAIRS SIZE STRAND INCHES
mm
INCHES
mm
INCHES
mm
1
2
22
22
22
22
22
22
22
22
22
22
22
22
Solid
Solid
Solid
Solid
Solid
7/30
7/30
7/30
7/30
7/30
7/30
7/30
0.010
0.010
0.010
0.010
0.012
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.30
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.156
0.218
0.229
0.249
0.293
0.228
0.240
0.262
0.300
0.366
3.94 24.5
5.54 24.5
5.82 24.5
6.32 24.5
7.44 24.5
5.79 24.5
6.10 24.5
6.65 24.5
7.62 24.5
9.30 24.5
C4008A
C4010A
C4014A
C4015A
C4017A
C6010A
C6014A
C6015A
C6017A
C6019A
C6023A
C6026A
3
4
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
6
2
3
4
6
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
9
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
12
15
0.410 10.40 24.5
0.456 11.58 24.5
* Capacitance between conductors
Color Code Chart
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
BlackꢀpairedꢀwithꢀYellow
Black paired with Brown
Black paired with Orange
RedꢀpairedꢀwithꢀWhite
RedꢀpairedꢀwithꢀGreen
RedꢀpairedꢀwithꢀBlue
RedꢀpairedꢀwithꢀYellow
RedꢀpairedꢀwithꢀBrown
RedꢀpairedꢀwithꢀOrange
GreenꢀpairedꢀwithꢀWhite
Green paired with Blue
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
43
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Unshielded
UL 2464, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
NOM.
C-C
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL O.D.
Applications:
CATALOG NO. OF AWG
COND.
CAP.*
pF/ft
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputers
NUMBER PAIRS SIZE STRAND INCHES
mm
INCHES
mm
INCHES
mm
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
1
2
18
18
18
18
18
18
18
18
18
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
0.013
0.013
0.013
0.013
0.013
0.013
0.013
0.013
0.013
0.33
0.33
0.33
0.33
0.33
0.33
0.33
0.33
0.33
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.206
0.320
0.338
0.372
5.23 26.3
8.13 26.3
8.59 26.3
9.45 26.3
C6101A
C6118A
C6103A
C6119A
C6120A
C6106A
C6121A
C6109A
C6111A
3
4
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
5
0.408 10.36 26.3
0.445 11.30 26.3
0.484 12.29 26.3
0.522 13.26 26.3
0.659 16.74 26.3
6
8
9
15
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
* Capacitance between conductors
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
BlackꢀpairedꢀwithꢀYellow
Black paired with Brown
Black paired with Orange
RedꢀpairedꢀwithꢀWhite
RedꢀpairedꢀwithꢀGreen
RedꢀpairedꢀwithꢀBlue
RedꢀpairedꢀwithꢀYellow
RedꢀpairedꢀwithꢀBrown
RedꢀpairedꢀwithꢀOrange
GreenꢀpairedꢀwithꢀWhite
Green paired with Blue
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
44
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Unshielded
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFEP
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. C-C
CAP.*
pF/ft
NOMINAL O.D.
Jacket:
C8116
•ꢀꢀFEP,ꢀredꢀorꢀasꢀrequested
CATALOG NO. OF AWG COND.
NUMBER PAIRS SIZE STRAND INCHES
mm INCHES mm INCHES mm
ꢀ
ꢀ
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+200°C
1
1
18
18
19/30
19/30
0.007
0.007
0.18 0.009 0.23 0.142 3.61
0.18 0.015 0.38 0.154 3.91
20.0
20.0
C8116
C8122
C8122
ꢀ
ꢀ
•ꢀFꢀ lexguard®ꢀPVC,ꢀnatural
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
*Capacitance between conductors
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀAudioꢀsystems
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Color Code Chart
NO. OF
PAIRS
COLOR
BlackꢀandꢀRed
1
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Features:
ꢀ
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
45
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Foil Shield
NEC Type CM (UL) c(UL), CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀsolidꢀorꢀstrandedꢀ
tinned copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
NOM. INSULATION NOM. JACKET
NOMINAL CAP.*
pF/ft
THICKNESS
THICKNESS
NOMINAL O.D.
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
CATALOG NO. OF AWG COND.
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
A
B
Jacket:
C7104A†
C1670A
C1676A
C1671A
C1672A
C1673A
1
2
22 7/.0096 0.013 0.33 0.035 0.89 0.185 4.70 35.0 62.0
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
22
22
22
22
22
Solid 0.010 0.25 0.032 0.81 0.218 5.54 32.0 57.0
Solid 0.010 0.25 0.032 0.81 0.249 6.32 28.0 50.0
Solid 0.010 0.25 0.032 0.81 0.292 7.42 25.0 45.0
Solid 0.010 0.25 0.032 0.81 0.338 8.59 25.0 45.0
Solid 0.010 0.25 0.032 0.81 0.419 10.64 25.0 45.0
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
4
Applications:
•ꢀꢀAudioꢀsystems
•ꢀꢀCommunicationꢀcircuits
•ꢀꢀInstrumentationꢀandꢀcontrolꢀuse
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
6
9
15
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Compliances:
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ
(UL:ꢀ75°C,ꢀ300V)
†
ꢀ
ꢀAlsoꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
ꢀ
ꢀ
ꢀ
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Color Code Chart
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
ꢀ
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
BlackꢀpairedꢀwithꢀYellow
Black paired with Brown
Black paired with Orange
RedꢀpairedꢀwithꢀWhite
RedꢀpairedꢀwithꢀGreen
RedꢀpairedꢀwithꢀBlue
RedꢀpairedꢀwithꢀYellow
RedꢀpairedꢀwithꢀBrown
RedꢀpairedꢀwithꢀOrange
GreenꢀpairedꢀwithꢀWhite
Green paired with Blue
1
2
3
4
5
6
7
8
9
Packaging:
ꢀ
10
11
12
13
14
15
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
46
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Foil Shield
UL 2095, NEC Type CM (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀsolidꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Shield:
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
NOMINAL CAP.*
ꢀ
ꢀ
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG COND.
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
A
B
Jacket:
51
22
Solid
0.010 0.25 0.050 1.27 0.715 18.16 25.0 45.0
C6451A
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
Applications:
ꢀ
ꢀ
ꢀ
•ꢀꢀIntercomꢀsystems
•ꢀꢀSoundꢀsystems
•ꢀꢀElectronicꢀinstrumentationꢀcontrolꢀ
systems
Color Code Chart
NO. OF
PAIRS
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
COLOR
BlueꢀpairedꢀwithꢀWhite
OrangeꢀpairedꢀwithꢀWhite
GreenꢀpairedꢀwithꢀWhite
BrownꢀpairedꢀwithꢀWhite
GrayꢀpairedꢀwithꢀWhite
1
2
3
4
5
Brown/Whiteꢀstriped
pairedꢀwithꢀWhite
Green/Whiteꢀstriped
pairedꢀwithꢀRed
ꢀ
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
18
19
20
35
36
37
38
39
40
Compliances:
ꢀ
Brown/Gray striped
pairedꢀwithꢀWhite
Green/Brown striped
pairedꢀwithꢀRed
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ
(UL:ꢀ75°C,ꢀ300V)
•ꢀꢀULꢀStyleꢀ2095ꢀ(UL:ꢀ80˚C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Gray/Whiteꢀstriped
pairedꢀwithꢀWhite
Green/Gray striped
pairedꢀwithꢀRed
ꢀ
ꢀ
ꢀ
Blue/Whiteꢀstriped
pairedꢀwithꢀWhite
6
7
BlueꢀpairedꢀwithꢀRed
OrangeꢀpairedꢀwithꢀRed
GreenꢀpairedꢀwithꢀRed
BrownꢀpairedꢀwithꢀRed
GrayꢀpairedꢀwithꢀRed
21
22
23
24
25
Brown/Whiteꢀstriped
pairedꢀwithꢀRed
Blue/Orange striped
pairedꢀwithꢀWhite
Brown/Gray striped
pairedꢀwithꢀRed
Packaging:
ꢀ
Blue/Green striped
pairedꢀwithꢀWhite
8
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Gray/Whiteꢀstriped
pairedꢀwithꢀRed
Blue/Brown striped
pairedꢀwithꢀWhite
Blue/Whiteꢀstriped
pairedꢀwithꢀRed
9
26
27
28
29
30
31
32
33
34
Blue paired with Black
Orange paired with Black
Green paired with Black
Brown paired with Black
Gray paired with Black
41
42
43
44
45
Blue/Gray striped
pairedꢀwithꢀWhite
Blue/Orange striped
pairedꢀwithꢀRed
10
11
12
13
14
15
16
17
Orange/Whiteꢀstriped
pairedꢀwithꢀWhite
Blue/Green striped
pairedꢀwithꢀRed
Orange/Green striped
pairedꢀwithꢀWhite
Blue/Brown striped
pairedꢀwithꢀRed
Blue/Whiteꢀstriped
paired with Black
46
47
48
49
50
51
Orange/Brown striped
pairedꢀwithꢀWhite
Blue/Gray striped
pairedꢀwithꢀRed
Blue/Orange striped
paired with Black
Orange/Gray striped
pairedꢀwithꢀWhite
Orange/Whiteꢀstriped
pairedꢀwithꢀRed
Blue/Green striped
paired with Black
Green/Whiteꢀstriped
pairedꢀwithꢀWhite
Orange/Green striped
pairedꢀwithꢀRed
Blue/Brown striped
paired with Black
Green/Brown striped
pairedꢀwithꢀWhite
Orange/Brown striped
pairedꢀwithꢀRed
Blue/Gray striped
paired with Black
Green/Gray striped
pairedꢀwithꢀWhite
Orange/Gray striped
pairedꢀwithꢀRed
Orange/Whiteꢀstriped
paired with Black
47
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Foil Shield
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀandꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
fluoropolymer
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
NOM. CAP.*
pF/ft
THICKNESS
NUMBER PAIRS SIZE STRAND INCHES mm
THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
INCHES mm INCHES mm
A
B
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
22 AWG CONDUCTORS
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
1
2
3
4
6
22
22
22
22
22
7/30
7/30
7/30
7/30
7/30
0.006
0.006
0.006
0.006
0.006
0.15
0.15
0.15
0.15
0.15
0.010 0.25 0.117 2.97 31.0 55.8
0.010 0.25 0.151 3.84 25.0 45.0
0.010 0.25 0.177 4.50 25.0 36.0
0.010 0.25 0.200 5.08 20.0 45.0
0.010 0.25 0.237 6.02 18.0 32.4
C3204
C3205
C3206
C3207
C3208
Jacket:
•ꢀꢀFluoropolymer,ꢀnatural
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+150°C
•ꢀꢀSequentialꢀfootageꢀmarkedꢀtoꢀfacilitateꢀ
installation
•ꢀꢀIncludesꢀripcord
ꢀ
ꢀ
ꢀ
24 AWG CONDUCTORS
ꢀ
2
3
4
6
24
24
24
24
7/32
7/32
7/32
7/32
7/32
0.006
0.006
0.006
0.006
0.006
0.15
0.15
0.15
0.15
0.15
0.010 0.25 0.130 3.30 22.0 39.6
0.010 0.25 0.152 3.86 18.0 32.4
0.010 0.25 0.170 4.32 17.0 30.6
0.010 0.25 0.200 5.08 17.0 30.6
0.012 0.30 0.290 7.04 17.0 30.6
C3150
C3153
C3151
C3165
C3152
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀEIAꢀRS-232ꢀcircuits
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
12.5 24
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀ(UL:ꢀ150°C,ꢀ300V)
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Color Code Chart
NO. OF
Features:
PAIRS
COLOR
Blackꢀ&ꢀYellow
ꢀ
•ꢀꢀWater-resistantꢀjacket
1
Packaging:
Redꢀ&ꢀViolet
2
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
DarkꢀBlueꢀ&ꢀBrown
3
Orangeꢀ&ꢀDarkꢀGreen
Pink & Gray
4
5
Tanꢀ&ꢀWhite
6
Light Blue & Light Green
Red/Whiteꢀ&ꢀWhite/Red
Orange/Whiteꢀ&ꢀWhite/Orange
Yellow/Whiteꢀ&ꢀWhite/Yellow
Gray/Whiteꢀ&ꢀWhite/Gray
Blue/Whiteꢀ&ꢀWhite/Blue
DarkꢀGreen/Yellow
7
8
9
10
11
12
1C
48
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Foil Shield
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀandꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFEP
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
NOM. CAP.*
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG
COND.
Separator:
•ꢀꢀPolyesterꢀtapeꢀwithꢀ25%ꢀoverlap
A
B
ꢀ
1
1
1
1
18
18
22
22
19/30
19/30
7/30
0.007 0.18 0.016 0.41 0.165 4.19 51.0 95.0
0.007 0.18 0.016 0.41 0.165 4.19 51.0 95.0
0.006 0.15 0.014 0.36 0.120 3.05 35.0 65.0
0.006 0.15 0.016 0.41 0.122 3.10 35.0 65.0
C8101**
C8104
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
C8103
7/30
C8109**
Jacket:
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
** FEP jacket
ꢀ
ꢀ
•ꢀꢀFEP,ꢀredꢀorꢀasꢀrequested
•ꢀꢀPVDF,ꢀredꢀorꢀasꢀrequested
C8101, C8109
Color Code Chart
ꢀ
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+200°C
C8104, C8103
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+150°C
NO. OF
PAIRS
COLOR
ꢀ
BlackꢀandꢀRed
1
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputerꢀsystems
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Features:
ꢀ
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
ꢀ
•ꢀꢀ1000'ꢀ(305m)ꢀreels
49
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Foil Shield
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀfoamꢀFEP
NOM. INSULATION NOM. JACKET
NOM. CAP.*
pF/ft
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
THICKNESS
THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
Separator:
•ꢀꢀPolyesterꢀtapeꢀwithꢀ25%ꢀoverlap
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
A
B
ꢀ
2
24
7/32
0.014 0.15 0.015 0.38 0.203 5.16 12.0 22.0
C8118
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
Jacket:
Color Code Chart
ꢀ
ꢀ
•ꢀꢀPVDF,ꢀgrayꢀorꢀasꢀrequested
NO. OF
PAIRS
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+150°C
COLOR
White/BlueꢀpairedꢀwithꢀBlue/White
White/OrangeꢀpairedꢀwithꢀOrange/White
Applications:
1
2
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputerꢀsystems
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀSuitableꢀforꢀRS232,ꢀRS422,ꢀRS485
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Features:
ꢀ
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
50
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Foil Shield
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24,ꢀ22ꢀandꢀ18ꢀAWGꢀfullyꢀannealedꢀ
stranded tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFEP
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
NOM. CAP.*
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG
COND.
Separator:
•ꢀꢀPolyesterꢀtapeꢀwithꢀ25%ꢀoverlap
A
B
ꢀ
1
3
1
1
24
24
22
18
7/32
7/32
0.006 0.15 0.014 0.36 0.108 2.69 30.0 60.0
0.006 0.15 0.014 0.36 0.161 4.09 25.0 45.0
0.006 0.15 0.014 0.36 0.120 3.05 35.0 65.0
0.007 0.18 0.014 0.36 0.160 4.06 51.0 90.0
C8127
C8113
C8126
C8123
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
7/30
19/30
Jacket:
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
•ꢀꢀFlexguard®ꢀPVC,ꢀnaturalꢀorꢀasꢀrequested
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
1
22
7/30
0.007 0.18 0.017 0.43 0.128 3.25 32.0 62.0
C8124**
Applications:
*A – Capacitance between conductors
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputerꢀsystems
*B – Capacitance between one conductor and other conductors connected to shield
**This item does not have a separator and has a shield fusible to the jacket to facilitate
removal along with the jacket while stripping.
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Compliances:
Color Code Chart
ꢀ
•ꢀꢀNECꢀArticleꢀ800
NO. OF
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
PAIRS
COLOR
BlackꢀandꢀRed
1
Features:
C8113
NO. OF PAIRS
COLOR
ꢀ
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
BlackꢀpairedꢀwithꢀWhite
BlackꢀpairedꢀwithꢀRed
Black paired with Green
1
2
3
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
51
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Foil Shield
NEC Type CMP (UL) c(UL) and/or CL2P
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀandꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33 or
stranded bare copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
PVC
NOM. INSULATION NOM. JACKET
NOM. CAP.*
NOMINAL O.D. pF/ft
THICKNESS
THICKNESS
CATALOG NO. OF AWG
NUMBER PAIRS SIZE
COND.
STRAND
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
INCHES mm INCHES mm INCHES mm
A
B
22 AWG, CL2P, c(UL) 150 VOLTS
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
2
3
4
6
22
22
22
22
7/30 TC
7/30 TC
7/30 TC
7/30 TC
0.007 0.180 0.010 0.25 0.157 3.99 37.0 66.0
0.007 0.180 0.010 0.25 0.194 4.42 30.0 53.0
0.007 0.180 0.010 0.25 0.207 4.75 30.0 53.0
0.007 0.180 0.010 0.25 0.246 5.74 27.0 48.0
C3352
C3353
C3354
C3356
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
Jacket:
•ꢀꢀFluoropolymer,ꢀnatural
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
•ꢀꢀSequentialꢀfootageꢀmarkedꢀtoꢀfacilitateꢀ
ꢀ
ꢀ
ꢀ
18 AWG, CL2P/CMP, c(UL) 150 VOLTS
2
4
18
18
7/26 BC
0.008 0.020 0.010 0.25 0.205 5.21 44.0 79.0
C3362
C3364
installation
ꢀ
•ꢀꢀIncludesꢀripcord
7/26 BC
0.008 0.020 0.010 0.25 0.277 7.04 33.0 59.0
Applications:
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀEIAꢀRS-232ꢀcircuits
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ150ꢀvolts
Color Code Chart
NO. OF
PAIRS
COLOR
Blackꢀ&ꢀYellow
Redꢀ&ꢀViolet
Compliances:
1
2
3
4
5
6
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀ(UL:ꢀ75°C,ꢀ300V)
•ꢀꢀNECꢀArticleꢀ725ꢀ(UL:ꢀ75°C,ꢀ150V)
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
DarkꢀBlueꢀ&ꢀBrown
Orangeꢀ&ꢀDarkꢀGreen
Pink & Gray
Features:
Tanꢀ&ꢀWhite
ꢀ
•ꢀꢀAbrasion-,ꢀchemical-ꢀandꢀwater-resistant
jacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
52
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Foil Shield
AWMꢀStyleꢀ2464,ꢀCSAꢀTypeꢀAWMꢀI/IIꢀA/B,ꢀNEC/CECꢀTypeꢀCMGꢀ(CSAꢀC/US)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
NOM.
NOM.
NOMINAL
DCR
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
INSULATION JACKET
NOM. CAP.*
NO.
THICKNESS THICKNESS NOMINAL O.D.
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD. CODE
Ω/KFT
pF/ft
CATALOG OF AWG COND.
COLOR
A
B
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
1
1
1
2
3
4
5
6
7
8
9
24 7/32 0.010 0.25 0.032 0.81 0.157 3.99 26.0 18.0
1
36.4 65.5
C4170A
C4209A
C4191A
C4171A
C4172A
C4173A
C4174A
C4175A
C4176A
C4177A
C4178A
C4179A
C4180A
C4181A
C4182A
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+105°C
24 7/32 0.010 0.25 0.032 0.81 0.157 3.99 26.0 18.0 Wht/Blk 36.4 65.5
24 7/32 0.009 0.23 0.030 0.76 0.148 3.78 26.0 16.5 Blk/Red 43.0 78.0
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputers
24 7/32 0.010 0.25 0.032 0.81 0.214 5.44 26.0 18.0
24 7/32 0.010 0.25 0.032 0.81 0.225 5.72 26.0 16.5
24 7/32 0.010 0.25 0.032 0.81 0.245 6.22 26.0 16.5
24 7/32 0.010 0.25 0.032 0.81 0.265 6.73 26.0 16.5
24 7/32 0.010 0.25 0.032 0.81 0.287 7.29 26.0 15.2
24 7/32 0.010 0.25 0.032 0.81 0.287 7.29 26.0 15.2
24 7/32 0.010 0.25 0.032 0.81 0.309 7.85 26.0 15.0
24 7/32 0.010 0.25 0.032 0.81 0.331 8.41 26.0 15.0
1
1
1
1
1
1
1
1
1
1
1
1
31.9 57.3
28.6 51.4
28.6 51.4
28.6 51.4
26.3 47.5
26.3 47.5
26.3 47.5
26.3 47.5
26.3 47.5
26.3 47.5
26.3 47.5
26.3 47.5
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀorꢀ600ꢀ
volts
Features:
ꢀ
ꢀ
ꢀ
•ꢀꢀExcellentꢀelectricalꢀproperties
•ꢀꢀSuperiorꢀshieldingꢀeffectivenessꢀ
•ꢀꢀ25%ꢀshieldꢀoverlapꢀprovidesꢀexcellentꢀ
shielding efficiency
10 24 7/32 0.010 0.25 0.032 0.81 0.359 9.12 26.0 14.0
15 24 7/32 0.010 0.25 0.032 0.81 0.410 10.41 26.0 13.8
19 24 7/32 0.010 0.25 0.032 0.81 0.432 10.97 26.0 13.5
25 24 7/32 0.010 0.25 0.032 0.81 0.505 12.83 26.0 12.7
ꢀ
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCCꢀDocketꢀ20780ꢀdemands
*A - Capacitance between conductors
*B - Capacitance between one conductor and other conductors connected to shield
ꢀ
•ꢀꢀGoodꢀflexibility
Compliances:
ꢀ
ꢀ
ꢀ
•ꢀꢀAWMꢀStyleꢀ2464ꢀ(CSA:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀTypeꢀAWMꢀ(105˚C,ꢀ600V)
•ꢀꢀCSAꢀCertifiedꢀCMGꢀtoꢀharmonizedꢀ
standard UL444 and CSA 22.2 No. 214
•ꢀꢀNEC/CECꢀTypeꢀCMGꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀCSAꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Color Code Chart
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
BlackꢀwithꢀRed
BlackꢀwithꢀWhite
Black with Green
Black with Blue
BlackꢀwithꢀYellow
Black with Brown
Black with Orange
RedꢀwithꢀWhite
RedꢀwithꢀGreen
RedꢀwithꢀBlue
GreenꢀwithꢀWhite
Green with Blue
GreenꢀwithꢀYellow
Green with Brown
Green with Orange
WhiteꢀwithꢀBlue
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPassesꢀCSAꢀFT4ꢀVerticalꢀFlameꢀTest
Packaging:
ꢀ
WhiteꢀwithꢀYellow
WhiteꢀwithꢀBrown
WhiteꢀwithꢀOrange
BlueꢀwithꢀYellow
Blue with Brown
Blue with Orange
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
RedꢀwithꢀYellow
RedꢀwithꢀBrown
RedꢀwithꢀOrange
53
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Foil Shield
AWMꢀStyleꢀ2464,ꢀCSAꢀTypeꢀAWMꢀI/IIꢀA/B,ꢀNEC/CECꢀTypeꢀCMGꢀ(CSAꢀC/US)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
NOMINAL
INSULATION
THICKNESS
NOMINAL
JACKET
NOMINAL
DCR
NOMINAL
CAP.*
NOMINAL
O.D.
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
NO.
THICKNESS
Ω/kft
pF/ft
CATALOG
OF AWG COND.
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
A
B
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+105°C
1
2
22 7/30 0.010 0.25 0.032 0.81 0.169 4.29 15.0 18.0 44.8 80.7
22 7/30 0.010 0.25 0.032 0.81 0.234 5.94 15.0 16.5 35.9 64.6
22 7/30 0.010 0.25 0.032 0.81 0.246 6.25 15.0 16.5 30.9 55.7
24 7/30 0.010 0.25 0.032 0.81 0.269 6.83 15.0 16.5 30.9 55.7
22 7/30 0.010 0.25 0.032 0.81 0.294 7.47 15.0 16.5 30.9 55.7
22 7/30 0.010 0.25 0.032 0.81 0.320 8.13 15.0 16.5 28.4 51.0
22 7/30 0.010 0.25 0.032 0.81 0.367 9.32 15.0 16.5 28.4 51.0
22 7/30 0.010 0.25 0.032 0.81 0.457 11.61 15.0 16.5 28.4 51.0
C4183A
C4184A
C4185A
C4186A
C4187A
C4188A
C4189A
C4190A
ꢀ
ꢀ
Applications:
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀratings:ꢀ300ꢀorꢀ600ꢀ
volts
3
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
4
5
6
9
15
Features:
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
ꢀ
•ꢀꢀExcellentꢀelectricalꢀproperties
•ꢀꢀSuperiorꢀshieldingꢀeffectivenessꢀ
•ꢀꢀ25%ꢀshieldꢀoverlapꢀprovidesꢀexcellentꢀ
shielding efficiency
Color Code Chart
ꢀ
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCCꢀDocketꢀ20780ꢀdemands
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
ꢀ
•ꢀGoodꢀflexibility
BlackꢀwithꢀRed
BlackꢀwithꢀWhite
Black with Green
Black with Blue
BlackꢀwithꢀYellow
Black with Brown
Black with Orange
RedꢀwithꢀWhite
RedꢀwithꢀGreen
RedꢀwithꢀBlue
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Compliances:
RedꢀwithꢀYellow
RedꢀwithꢀBrown
RedꢀwithꢀOrange
GreenꢀwithꢀWhite
Green with Blue
ꢀ
ꢀ
ꢀ
•ꢀꢀAWMꢀStyleꢀ2464ꢀ(CSA:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀTypeꢀAWMꢀ(105˚C,ꢀ600V)
•ꢀꢀCSAꢀCertifiedꢀCMGꢀtoꢀharmonizedꢀ
standard UL444 and CSA 22.2 No. 214
•ꢀꢀNEC/CECꢀTypeꢀCMGꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀCSAꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPassesꢀCSAꢀFT4ꢀVerticalꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
54
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Foil Shield, Mid-Cap
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
fluoropolymer
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
INCHES mm INCHES mm INCHES mm
NOM. CAP.*
Shield:
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG
NUMBER PAIRS SIZE
COND.
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
STRAND
A
B
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
2
3
24
24
24
24
24
7/32
7/32
7/32
7/32
7/32
0.010 0.25 0.010 0.25 0.150 3.81 17.0 30.0
0.010 0.25 0.010 0.25 0.177 4.50 15.0 27.0
0.010 0.25 0.010 0.25 0.201 5.11 15.0 27.0
0.010 0.25 0.010 0.25 0.214 5.18 15.0 27.0
0.010 0.25 0.010 0.25 0.239 6.07 14.0 25.0
C3214
C3215
C3216
C3217
C3218
Jacket:
•ꢀꢀFluoropolymer,ꢀnatural
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+150°C
•ꢀꢀSequentialꢀfootageꢀmarkedꢀtoꢀfacilitateꢀ
installation
•ꢀIncludesꢀripcord
ꢀ
ꢀ
ꢀ
4
4.5
6
ꢀ
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀEIAꢀRS-232ꢀandꢀRS-422ꢀcircuits
•ꢀꢀRemoteꢀcontrolꢀcircuits
Color Code Chart
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
NO. OF
PAIRS
COLOR
BlackꢀpairedꢀwithꢀYellow
RedꢀpairedꢀwithꢀViolet
DarkꢀBlueꢀpairedꢀwithꢀBrown
OrangeꢀpairedꢀwithꢀDarkꢀGreen
Pink paired with Gray
1
2
3
4
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀ(UL:ꢀ150°C,ꢀ300V)
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
5
Features:
TanꢀpairedꢀwithꢀWhite
6
1C
ꢀ
•ꢀꢀAbrasion-,ꢀchemical-ꢀandꢀwater-resistantꢀ
GreenꢀwithꢀYellowꢀStripe
jacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
55
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Foil Shield, Lo-Cap®
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
fluoropolymer
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. JACKET
THICKNESS
STRAND INCHES mm INCHES mm
NOM. CAP.*
pF/ft
IMPED.
Ω
NOM
Shield:
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
NUMBER
PAIRS SIZE
A
B
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
2
3
4
6
24
24
24
24
7/32
7/32
7/32
7/32
0.010 0.25 0.159 4.04 15.0 27.00
94.0
C3028
C3029
C3030
C3031
Jacket:
•ꢀꢀFluoropolymer,ꢀnatural
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+150°C
•ꢀꢀSequentialꢀfootageꢀmarkedꢀtoꢀfacilitateꢀ
0.010 0.25 0.183 4.65 14.0 25.00 107.0
0.010 0.25 0.246 6.25 14.0 25.00 107.0
0.012 0.30 0.285 7.24 13.0 23.00 115.0
ꢀ
ꢀ
ꢀ
installation
•ꢀꢀIncludesꢀripcord
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀEIAꢀRS-232ꢀandꢀRS-422ꢀcircuits
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀLowꢀcapacitanceꢀrequirements
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Color Code Chart
NO. OF
PAIRS
COLOR
BlackꢀpairedꢀwithꢀYellow
RedꢀpairedꢀwithꢀViolet
DarkꢀBlueꢀpairedꢀwithꢀBrown
OrangeꢀpairedꢀwithꢀDarkꢀGreen
Pink paired with Gray
1
2
3
4
5
6
Compliances:
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀ(UL:ꢀ150°C,ꢀ300V)
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
TanꢀpairedꢀwithꢀWhite
Features:
ꢀ
•ꢀꢀAbrasion-,ꢀchemical-ꢀandꢀwater-resistant
jacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
56
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Overall Foil & TC Braid Shield, Lo-Cap®
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀfoamꢀFEP
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
mm INCHES mm INCHES mm
NOM. CAP.*
pF/ft
Shield:
NOMINAL O.D.
CATALOG NO. OF AWG COND.
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
NUMBER PAIRS SIZE STRAND INCHES
A
B
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀTinnedꢀcopperꢀbraid,ꢀ90%ꢀcoverage
1
2
24
24
7/32
7/32
0.026
0.019
0.66 0.014 0.36 0.208 5.28 12.0 22.0
0.48 0.017 0.43 0.280 6.93 12.0 22.0
C8117
C8129
Jacket:
C8117
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
•ꢀꢀFEP,ꢀredꢀorꢀasꢀrequested
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+200°C
C8129
Color Code Chart
C8117
NO. OF PAIRS
ꢀ
ꢀ
•ꢀFꢀ lexguard®ꢀPVC,ꢀnatural
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
COLOR
Applications:
•ꢀꢀComputerꢀsystems
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
White/BlueꢀpairedꢀwithꢀBlue/White
1
ꢀ
ꢀ
ꢀ
ꢀ
C8129
NO. OF PAIRS
COLOR
White/BlueꢀpairedꢀwithꢀBlue/White
White/OrangeꢀpairedꢀwithꢀOrange/White
1
2
Compliances:
•ꢀꢀNECꢀArticleꢀ800
ꢀ
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Features:
ꢀ
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
57
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Individually Shielded
ULꢀ2717,ꢀULꢀ2835,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL)ꢀCMHꢀorꢀCMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
NOMINAL CAP.*
pF/ft
polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
CATALOG NO. OF AWG COND.
A
B
Shield:
POLYPROPYLENE INSULATION — NEC TYPE CM(UL) c(UL) CMH
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairs
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
2
22
7/30
0.007 0.18 0.020 0.51 0.160 4.06 30.0 45.0
C1352A
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
POLYPROPYLENE INSULATION — UL STYLE 2717, UL STYLE 2835, CM(UL) c(UL) CMH
ꢀ
2
22
SR-PVC INSULATION — UL STYLE 2464, CM(UL) c(UL) CMG
20 7/28 0.010 0.25 0.041 1.04 0.305 7.75 46.0 82.0
7/30
0.010 0.25 0.028 0.71 0.208 5.028 25.0 53.5
C1353A**
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
ꢀ
ꢀ
2
C7106A
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
**Individually shielded with overall shield
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀWhereꢀtotalꢀisolationꢀofꢀsignalꢀisꢀrequired
•ꢀꢀComputers
•ꢀꢀControlꢀcircuits
•ꢀꢀIndustrialꢀequipment
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Color Code Chart
NO. OF
PAIRS
COLOR
Black/Red
Features:
1
2
ꢀ
•ꢀꢀExcellentꢀhighꢀfrequencyꢀproperties
Green/White
ꢀ
•ꢀꢀMechanicalꢀdurability
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75˚C,ꢀ
300V)
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀStyleꢀ2717ꢀ(UL:ꢀ80˚C)
•ꢀꢀULꢀStyleꢀ2835ꢀ(UL:ꢀ60˚C,ꢀ30V)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀCMHꢀ(CSA:ꢀ60˚C)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀCSAꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
ꢀ
•ꢀꢀPassesꢀCSAꢀCMHꢀorꢀCMGꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
58
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Individually Shielded
CSAꢀTypeꢀAWMꢀI/IIꢀA/B,ꢀNEC/CECꢀTypeꢀCMGꢀ(CSAꢀC/US)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVCꢀ
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL
INSULATION
THICKNESS
NOMINAL
JACKET
NOMINAL
NOMINAL
CAP.*
Shield:
NOMINAL
O.D.
DCR
NO.
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairs
THICKNESS
Ω/kft
pF/ft
CATALOG
OF AWG COND.
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
A
B
2
22 7/30 0.007 0.18 0.020 0.51 0.160 4.06 16.6 7.2 67.0 121.0
C4203A
ꢀ
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Jacket:
•ꢀꢀPVC,ꢀgray
ꢀ
ꢀ
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+105˚C
Applications:
Color Code Chart
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀWhereꢀtotalꢀisolationꢀofꢀsignalꢀisꢀrequired
NO. OF
PAIRS
COLOR
•ꢀꢀComputers
•ꢀꢀControlꢀcircuits
•ꢀꢀIndustrialꢀequipmentꢀ
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀorꢀ600ꢀ
BlackꢀwithꢀRed
GreenꢀwithꢀWhite
1
2
volts
Features:
ꢀ
•ꢀꢀExcellentꢀhigh-frequencyꢀproperties
ꢀ
•ꢀꢀMechanicalꢀdurability
Compliances:
ꢀ
•ꢀꢀCSAꢀTypeꢀAWMꢀ(105˚C,ꢀ600V)
ꢀ
•ꢀꢀCSAꢀCertifiedꢀCMGꢀtoꢀharmonizedꢀ
standard UL444 and CSA (22.2 No. 2)
ꢀ
ꢀ
ꢀ
•ꢀꢀNEC/CECꢀTypeꢀCMGꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀCSAꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
ꢀ
•ꢀꢀPassesꢀCSAꢀFT4ꢀVerticalꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
59
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Individually Shielded, Overall Shield
ULꢀ2464,ꢀULꢀ2576,ꢀNECꢀTypeꢀCMRꢀ(UL)ꢀc(UL),ꢀCSAꢀCMG
Product Construction:
Conductor:
ꢀ
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVCꢀ
per UL 1061
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
NOMINAL CAP.*
pF/ft
NOMINAL O.D.
Shield:
CATALOG NO. OF AWG COND.
A
B
ꢀ
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀplusꢀanꢀoverallꢀ
foil shield and drain wire
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
25%ꢀoverlap,ꢀfoilꢀfacingꢀin
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
2
22 7/30 0.010 0.25 0.035 0.889 0.175 4.45 40
71.5
C1350A
x
x
0.280 7.11
*A – Capacitance between conductors
Jacket:
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
•ꢀꢀPVC,ꢀbeige
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
Color Code Chart
Applications:
NO. OF
PAIRS
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputerꢀinterconnections
COLOR
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀIndustrialꢀequipmentꢀcontrol
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Black/White
Black/Yellow
1
2
Features:
ꢀ
•ꢀꢀExcellentꢀhighꢀfrequencyꢀproperties
ꢀ
•ꢀꢀMechanicalꢀdurability
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80˚C,ꢀ300V)
•ꢀꢀULꢀStyleꢀ2576
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
60
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Individually Foil Shielded
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
fluoropolymer
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
INCHES mm INCHES mm INCHES mm
NOM. CAP.**
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG
NUMBER PAIRS SIZE
COND.
STRAND
A
B
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil,
2
3
22
22
7/30
7/30
0.006 0.15 0.010 0.25 0.147 3.73 35.0 63.0
0.006 0.15 0.010 0.25 0.184 4.67 35.0 63.0
C3156*
eachꢀwithꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
†
C3157
*ꢀCabledꢀonꢀcommonꢀaxisꢀtoꢀreduceꢀdiameter,ꢀfoilꢀout,ꢀcommonꢀdrainꢀwire
**A – Capacitance between conductors
**B – Capacitance between one conductor and other conductors connected to shield
†3 individually shielded pairs with separate drain wires
Jacket:
ꢀ
ꢀ
ꢀ
•ꢀꢀFluoropolymer,ꢀred
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+150°C
•ꢀꢀSequentialꢀfootageꢀmarkedꢀtoꢀfacilitateꢀ
installation
Color Code Chart
ꢀ
•ꢀꢀIncludesꢀripcord
C3156
Applications:
NO. OF PAIRS
COLOR
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPointꢀofꢀsaleꢀsystems
BlackꢀpairedꢀwithꢀRed
WhiteꢀpairedꢀwithꢀGreen
1
2
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
C3157
NO. OF PAIRS
COLOR
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
1
2
3
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀ(UL:ꢀ150°C,ꢀ300V)
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Features:
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀforꢀexcellentꢀ
signal isolation
ꢀ
•ꢀꢀAbrasion-,ꢀchemical-ꢀandꢀwater-resistantꢀ
jacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
61
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Individually Foil Shielded
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀthruꢀ22ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFEPꢀorꢀ
foamed FEP
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
INCHES mm INCHES mm INCHES mm
NOM. CAP.*
pF/ft
NOMINAL O.D.
CATALOG NO. OF AWG
NUMBER PAIRS SIZE
COND.
STRAND
A
B
Pair Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil,
2
2
3
6
24
22
22
22
7/32
7/30
7/30
7/30
0.019 0.48 0.015 0.38 0.255 7.48 35.0 76.0
0.006 0.15 0.014 0.36 0.186 4.72 43.0 75.0
0.010 0.25 0.018 0.46 0.237 6.02 35.0 76.0
0.010 0.25 0.018 0.45 0.314 7.98 35.0 76.0
C8134
C8105
C8131
C8133
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀwithꢀstrandedꢀ
tinned copper drain wire
Jacket:
ꢀ
ꢀ
•ꢀFꢀ lexguard®ꢀPVC,ꢀnatural
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputerꢀsystems
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Color Code Chart
C8105
NO. OF PAIRS
COLOR
BlackꢀpairedꢀwithꢀRed
WhiteꢀpairedꢀwithꢀGreen
1
2
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800
C8131
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
NO. OF PAIRS
COLOR
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
1
2
3
Features:
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀforꢀexcellentꢀ
signal isolation
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
C8133
NO. OF PAIRS
ꢀ
COLOR
Packaging:
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
BlackꢀpairedꢀwithꢀYellow
Black paired with Brown
1
2
3
4
5
6
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
C8134
NO. OF PAIRS
COLOR
White/BlueꢀpairedꢀwithꢀBlue/White
1
2
White/OrangeꢀpairedꢀwithꢀOrange/White
62
Communication & Control Cable, Multi-Paired
Electronics
Multi-Paired, Individually Foil Shielded
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFEP
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
INCHES mm INCHES mm INCHES mm
NOM. CAP.*
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG
NUMBER PAIRS SIZE
COND.
Pair Shield:
STRAND
A
B
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil,
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀwithꢀstrandedꢀ
tinned copper drain wire
2
6
22
22
7/30
7/30
0.006 0.15 0.014 0.36 0.186 4.72 35.0 65.0
0.010 0.25 0.015 0.38 0.309 7.85 30.0 65.0
C8112
C8132
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Jacket:
•ꢀꢀFEP,ꢀredꢀorꢀasꢀrequested
ꢀ
ꢀ
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+200°C
Color Code Chart
C8112
NO. OF PAIRS
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputerꢀsystems
COLOR
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
BlackꢀpairedꢀwithꢀRed
WhiteꢀpairedꢀwithꢀGreen
1
2
Compliances:
C8132
NO. OF PAIRS
COLOR
ꢀ
•ꢀꢀNECꢀArticleꢀ800
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
BlackꢀpairedꢀwithꢀYellow
Black paired with Brown
1
2
3
4
5
6
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Features:
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀforꢀexcellentꢀ
signal isolation
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
ꢀ
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
63
Electronics
Communication & Control Cable, Multi-Paired
Multi-Paired, Individually Foil Shielded
NEC Type CMP (UL) c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀfoamꢀFEP
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
INCHES mm INCHES mm INCHES mm
NOM. CAP.*
pF/ft
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
CATALOG NO. OF AWG
NUMBER PAIRS SIZE
COND.
Pair Shield:
STRAND
A
B
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀwithꢀstrandedꢀ
tinned copper drain wire
2
24
7/32
0.019 0.48 0.018 0.46 0.261 6.63 12.5 22.0
C8128
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Jacket:
ꢀ
ꢀ
•ꢀꢀPVDF,ꢀgrayꢀorꢀasꢀrequested
Color Code Chart
•ꢀꢀTemperatureꢀrange:ꢀ-40°Cꢀtoꢀ+150°C
Applications:
NO. OF PAIRS
COLOR
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputerꢀsystems
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀProcessꢀcontrolꢀandꢀinstrumentation
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
White/BlueꢀpairedꢀwithꢀBlue/White
1
2
White/OrangeꢀpairedꢀwithꢀOrange/White
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Features:
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀforꢀexcellentꢀ
signal isolation
ꢀ
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
64
Communication & Control Cable, Multi-Paired
Electronics
Power-Limited Tray Cable, Individually Shielded
ULꢀ2464,ꢀNECꢀTypeꢀPLTCꢀANDꢀCSAꢀCMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀorꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVCꢀ
•ꢀꢀColorꢀcode:ꢀEachꢀpairꢀblackꢀandꢀred,ꢀ
numbered at one-inch intervals
Shield:
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
NOMINAL CAP.*
ꢀ
ꢀ
•ꢀꢀPairsꢀareꢀ100%ꢀindividuallyꢀshieldedꢀwithꢀ
Flexfoil® aluminum/polyester, foil facing in
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwireꢀeachꢀ
NOMINAL O.D.
pF/ft
CATALOG NO. OF AWG COND.
A
B
pair
2
3
22
22
22
22
22
22
18
18
18
18
18
18
18
7/30
7/30
7/30
7/30
7/30
7/30
0.016 0.41 0.042 1.07 0.327 8.31 38.5 69.5
0.015 0.41 0.042 1.07 0.345 8.76 38.5 69.5
0.015 0.41 0.042 1.07 0.378 9.60 38.5 69.5
0.015 0.41 0.053 1.35 0.469 11.91 38.5 69.5
0.015 0.41 0.053 1.35 0.542 13.77 38.5 69.5
0.015 0.41 0.053 1.35 0.589 14.96 38.5 69.5
C0570A
C0571A
C0572A
C0573A
C0574A
C0575A
C0584A
C0585A
C0586A
C0587A
C0588A
C0589A
C0590A
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+105°C
ꢀ
ꢀ
4
6
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPower-limitedꢀcircuitsꢀ
•ꢀꢀIntercomꢀsystemsꢀ
•ꢀꢀBusinessꢀmachinesꢀ
•ꢀꢀCashꢀregistersꢀ
•ꢀꢀComputerꢀinterconnectsꢀ
•ꢀꢀSuitablyꢀmarkedꢀforꢀappropriateꢀtrayꢀ
cable installations
•ꢀꢀBurglarꢀalarms
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
9
11
2
16/30 0.016 0.41 0.042 1.07 0.380 9.65 50.5 91.0
16/30 0.016 0.41 0.053 1.35 0.437 11.10 50.5 91.0
16/30 0.016 0.41 0.053 1.35 0.478 12.14 50.5 91.0
16/30 0.016 0.41 0.053 1.35 0.566 14.38 50.5 91.0
16/30 0.016 0.41 0.063 1.60 0.679 17.25 50.5 91.0
16/30 0.016 0.41 0.063 1.60 0.738 18.75 50.5 91.0
16/30 0.015 0.38 0.063 1.60 0.845 21.46 50.5 91.0
3
4
ꢀ
ꢀ
6
9
Features:
•ꢀꢀSuperiorꢀtemperatureꢀcharacteristicsꢀ
•ꢀꢀRobust,ꢀhighlyꢀdurableꢀ
•ꢀꢀSunlight-resistantꢀjacket
11
15
ꢀ
ꢀ
ꢀ
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Compliances:
•ꢀꢀNECꢀArticleꢀ725ꢀPower-LimitedꢀTrayꢀ
Cableꢀ(UL:ꢀ105°C,ꢀ300V)ꢀ
ꢀ
Color Code Chart
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
NO. OF
PAIRS
COLOR
Black
Rꢀed
1 thru 15
Each pair marked and numbered
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
65
Electronics
Communication & Control Cable, Multi-Paired
Power-Limited Tray Cable, Foil Shield or Foil/Braid Shield
UL 2464, NEC Type PLTC/CM, CSA CMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀorꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVCꢀorꢀ
FMPE
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
NOMINAL CAP.*
pF/ft
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
CATALOG NO. OF AWG COND.
Shield:
A
B
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
PVC INSULATION — UL STYLE 2464, NEC TYPE PLT/CM, CSA CMG, 105°C
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
•ꢀꢀ65%ꢀtinnedꢀcopperꢀbraidꢀ(C7101A,ꢀ
C7103A and C7107A only)
2
3
4
6
22 7/.0096 0.015 0.38 0.042 1.07 0.294 7.47 32.0 57.0
22 7/.0096 0.015 0.38 0.042 1.07 0.309 7.85 29.0 52.2
22 7/.0096 0.015 0.38 0.042 1.07 0.337 8.56 29.0 52.2
22 7/.0096 0.015 0.38 0.042 1.35 0.418 10.62 26.5 47.7
22 7/.0096 0.015 0.38 0.042 1.35 0.480 12.19 26.5 47.7
C0550A
C0551A
C0552A
C0553A
C0554A
C0555A
C0556A
C0560A
C0561A
C0562A
C0563A
C0564A
C0566A
ꢀ
ꢀ
Jacket:
•ꢀꢀPVC,ꢀgrayꢀorꢀblack
•ꢀꢀTemperatureꢀrange:ꢀ
-20°Cꢀtoꢀ+60°Cꢀorꢀ+105°C
9
ꢀ
ꢀ
11
15
2
3
4
6
9
15
22
22
7/30
7/30
0.015 0.38 0.053 1.35 0.520 13.21 27.0 48.5
0.015 0.38 0.053 1.35 0.592 15.04 27.0 48.5
18 16/30 0.016 0.41 0.042 1.07 0.314 7.98 40.0 72.0
18 16/30 0.016 0.41 0.042 1.35 0.403 10.24 33.5 60.3
18 16/30 0.016 0.41 0.042 1.35 0.440 11.18 33.5 60.3
18 16/30 0.016 0.41 0.042 1.35 0.519 13.18 30.5 54.9
18 16/30 0.016 0.41 0.042 1.60 0.622 15.80 30.5 54.9
18 16/30 0.016 0.41 0.042 1.60 0.622 15.80 30.5 54.9
Applications:
•ꢀꢀPower-limitedꢀcircuits
•ꢀꢀIntercomꢀsystems
•ꢀꢀBusinessꢀmachines
•ꢀꢀComputerꢀinterconnects
•ꢀꢀSuitablyꢀmarkedꢀforꢀappropriateꢀtrayꢀ
cable installations
•ꢀꢀPetrochemicalꢀcontrolꢀsystems
•ꢀꢀBurglarꢀalarms
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
*A – Capacitance between conductors
*B – Capacitance between one conductor
and other conductors connected to shield
Color Code Chart
NO. OF
PAIRS
ꢀ
ꢀ
ꢀ
COLOR
Black/Red
1 thru 9
Each pair marked and numbered
Features:
ꢀ
ꢀ
ꢀ
•ꢀꢀSuperiorꢀtemperatureꢀcharacteristics
•ꢀꢀRobust,ꢀhighlyꢀdurable
•ꢀꢀSunlight-resistantꢀjacket
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀPower-LimitedꢀTrayꢀ
Cableꢀ(UL:ꢀ105°Cꢀorꢀ60°C,ꢀ300V)
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀCommunicationsꢀCableꢀ
(UL:ꢀ105°Cꢀorꢀ60°C,ꢀ300V)
LO-CAP® DATACOM COLOR CODE WITH 65% TINNED COPPER BRAID
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀ†ꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)ꢀorꢀCMꢀc(UL)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
NOMINAL CAP.*
pF/ft
A
NOMINAL O.D.
CATALOG NO. OF AWG COND.
B
FOAMED POLYETHYLENE INSULATION —
NEC TYPE PLTC/CM, CEC CM c(UL), 60°C
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Packaging:
1
2
3
22 7/.0096 0.024 0.61 0.037 0.94 0.261 6.63 11.5 20.5
22 7/.0096 0.017 0.43 0.042 1.07 0.343 8.71 11.0 19.6
22 7/.0096 0.015 0.38 0.042 1.07 0.344 8.74 11.0 19.6
C7112A
C7114A
C7116A
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
† ULꢀStyleꢀ2464ꢀonlyꢀavailableꢀonꢀPVCꢀinsulationꢀ
constructions
*A – Capacitance between conductors
*B – Capacitance between one conductor
and other conductors connected to shield
Color Code Chart
NO. OF
PAIRS
COLOR
White/BlueꢀStripeꢀandꢀBlue/WhiteꢀStripe
White/OrangeꢀStripeꢀandꢀOrange/WhiteꢀStripe
White/GreenꢀStripeꢀandꢀGreen/WhiteꢀStripe
1
2
3
66
Electronics
Computer Cable
4
Index
Page
Multi-Conductor,
Foil Shield
68-69
Multi-Conductor,
Foil/Braid Shield
70-71
Multi-Conductor,
Foil/Braid Shield, Lo-Cap®
72
73
Multi-Paired,
Foil Shield
Multi-Paired,
Foil Shield, Lo-Cap®
74
Multi-Paired,
Foil/Braid Shield
75
General Cable manufactures
a comprehensive line of
computer cables.
General Cable also offers a
variety of put-ups for computer
cables to meet your individual
requirements.
Multi-Paired, Foil/Braid
Shield, Lo-Cap®
76-79
80-82
83
Multi-Paired, Individually
Foil Shielded
This complete line of paired and
unpaired, shielded computer
cables—which are UL and
CSA listed—are used primarily
for the internal or external
interconnection of electronic
equipment and computers.
Applications include data
transmission, CAD/CAM,
telemetering, data displays,
computer print-out, credit
verification systems and similar
applications.
Our products are manufactured
to meet the latest UL, CSA
and NEC requirements and
approvals.
Multi-Paired, Individually
Foil Shielded, Lo-Cap®
Multi-Paired, Individually
Foil/Braid Shielded,
Lo-Cap®
84
67
Electronics
Computer Cable
Multi-Conductor, Foil Shield
ULꢀ2464,ꢀNECꢀTypeꢀCMRꢀ(UL)ꢀc(UL),ꢀCSAꢀCMG
Product Construction:
Conductor:
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
ꢀ
copper per ASTM B-33
Insulation:
NOMINAL
NOMINAL
JACKET
NOMINAL DCR NOMINAL
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVCꢀ
INSULATION
NOMINAL
O.D.
Ω/kft
CAP.*
pF/ft
NO.
per UL 1061
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
THICKNESS THICKNESS
@20˚C
CATALOG OF AWG COND.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
A
B
Shield:
2
3
4
5
6
7
8
9
24 7/32 0.010 0.25 0.032 0.81 0.157 3.99 26.0 7.2 36.0 64.0
24 7/32 0.010 0.25 0.032 0.81 0.164 4.17 26.0 7.2 33.0 59.0
24 7/32 0.010 0.25 0.032 0.81 0.175 4.45 26.0 7.2 33.0 59.0
24 7/32 0.010 0.25 0.032 0.81 0.188 4.78 26.0 7.2 33.0 59.0
24 7/32 0.010 0.25 0.032 0.81 0.201 5.11 26.0 7.2 30.0 55.0
24 7/32 0.010 0.25 0.032 0.81 0.201 5.11 26.0 7.2 30.0 55.0
24 7/32 0.010 0.25 0.032 0.81 0.215 5.46 26.0 7.2 30.0 55.0
24 7/32 0.010 0.25 0.032 0.81 0.228 5.79 26.0 7.2 30.0 55.0
C0740A
C0741A
C0742A
C0753A
C0743A
C0754A
C0744A
C0755A
C0745A
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester
withꢀ25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
ꢀ
ꢀ
Applications:
•ꢀꢀComputerꢀinterconnections
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀIndustrialꢀequipmentꢀcontrol
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
10 24 7/32 0.010 0.25 0.032 0.81 0.245 6.22 26.0 7.2 30.0 55.0
*A – Capacitance between conductors
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
*B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart 1 - For cables up to and including 10 conductors
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
Light Blue
Orange
Yellow
Violet
Gray
Black
White
Red
Light Green
Light Brown
1
2
3
4
5
6
7
8
9
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
10
NOMINAL
INSULATION
THICKNESS THICKNESS
NOMINAL
NOMINAL DCR NOMINAL
JACKET
NOMINAL
O.D.
Ω/kft
CAP.*
pF/ft
NO.
CATALOG OF AWG COND.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
@20˚C
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
A
B
Packaging:
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
15 24 7/32 0.010 0.25 0.032 0.81 0.276 7.01 26.0 7.2 30.0 55.0
20 24 7/32 0.010 0.25 0.032 0.81 0.303 7.70 26.0 7.2 30.0 55.0
25 24 7/32 0.010 0.25 0.032 0.81 0.333 8.46 26.0 7.2 30.0 55.0
30 24 7/32 0.010 0.25 0.032 0.81 0.351 8.92 26.0 7.2 30.0 55.0
40 24 7/32 0.010 0.25 0.032 0.81 0.391 9.93 26.0 7.2 30.0 55.0
50 24 7/32 0.010 0.25 0.032 0.81 0.439 11.15 26.0 7.2 30.0 55.0
C0746A
C0747A
C0748A
C0749A
C0750A
C0751A
ꢀ
packaging and color options
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart 2 Per ICEA - For cables of 15 thru 50 conductors
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
COLOR
COLOR
Black
White
Red
Light Green
Orange
Light Blue
White/Black
Red/Black
Light Green/Black
Orange/Black
Light Blue/Black
Black/White
Red/White
LightꢀGreen/White
LightꢀBlue/White
Black/Red
White/Red
Orange/Red
LightꢀBlue/Red
Red/Green
Orange/Green
Black/White/Red
White/Black/Red
Red/Black/White
LightꢀGreen/Black/White
Orange/Black/White
LightꢀBlue/Black/White
Black/Red/Green
White/Red/Green
White/Black/Green
Red/White/Green
LightꢀGreen/White/Blue
Orange/Red/Green
LightꢀBlue/Red/Green
Black/White/Blue
White/Black/Blue
Red/White/Blue
LightꢀGreen/Orange/Red
Orange/Red/Blue
LightꢀBlue/Red/Orange
Black/Orange/Red
1
2
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
3
Red/Black/Green
4
Light Green/Black/Orange
Orange/Black/Green
LightꢀBlue/White/Orange
Black/White/Orange
White/Red/Orange
Orange/White/Blue
White/Red/Blue
5
6
7
8
9
10
11
12
13
Black/White/Green
68
Computer Cable
Electronics
Multi-Conductor, Foil Shield
ULꢀ2464,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL)ꢀorꢀCMRꢀ(UL)ꢀc(UL),ꢀCSAꢀCMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀorꢀ20ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVCꢀ
orꢀPVC
NOMINAL
INSULATION
THICKNESS
NOMINAL
JACKET
NOMINAL DCR NOMINAL
ꢀ
ꢀ
NOMINAL
O.D.
Ω/kft
CAP.*
pF/ft
THICKNESS
@20˚C
CATALOG NO. OF AWG COND.
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
A
B
Shield:
S-R PVC – CMR (UL) c(UL)
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
2
3
4
6
8
22 7/30 0.010 0.25 0.032 0.81 0.169 4.29 16.5 6.3 36.0 65.0
22 7/30 0.010 0.25 0.032 0.81 0.177 4.50 16.5 6.3 36.0 65.0
22 7/30 0.010 0.25 0.032 0.81 0.190 4.83 16.5 6.3 36.0 65.0
22 7/30 0.010 0.25 0.032 0.81 0.219 5.56 16.5 6.3 34.0 61.0
22 7/30 0.010 0.25 0.032 0.81 0.235 5.97 16.5 6.3 34.0 61.0
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
C0760A
C0761A
C0762A
C0763A
C0764A
C0765A
C0766A
C0767A
C0768A
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
ꢀ
ꢀ
Applications:
•ꢀꢀComputerꢀinterconnections
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀIndustrialꢀequipmentꢀcontrol
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
10 22 7/30 0.010 0.25 0.032 0.81 0.269 6.83 16.5 6.3 34.0 61.0
15 22 7/30 0.010 0.25 0.032 0.81 0.304 7.72 16.5 6.3 34.0 61.0
20 22 7/30 0.010 0.25 0.032 0.81 0.335 8.51 16.5 6.3 34.0 61.0
25 22 7/30 0.010 0.25 0.032 0.81 0.369 9.37 16.5 6.3 34.0 61.0
PVC – CM (UL) c(UL)
Compliances:
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ-ꢀ20ꢀorꢀ22ꢀ
AWGꢀ(UL:ꢀ75˚C)
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ-ꢀ20ꢀorꢀ22ꢀ
AWGꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
2
3
4
6
8
20 7/28 0.016 0.41 0.032 0.81 0.207 5.26 11.0 6.3 39.0 70.0
20 7/28 0.016 0.41 0.032 0.81 0.217 5.51 11.0 6.3 39.0 70.0
20 7/28 0.016 0.41 0.032 0.81 0.236 5.99 11.0 6.3 39.0 70.0
20 7/28 0.016 0.41 0.032 0.81 0.276 7.01 11.0 6.3 37.0 66.0
20 7/28 0.016 0.41 0.032 0.81 0.297 7.54 11.0 6.3 37.0 66.0
C0780A
C0781A
C0782A
C0783A
C0784A
C0785A
C0786A
C0787A
C0788A
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
10 20 7/28 0.016 0.41 0.032 0.81 0.345 8.76 11.0 6.3 37.0 66.0
15 20 7/28 0.016 0.41 0.032 0.81 0.393 9.98 11.0 6.3 37.0 66.0
20 20 7/28 0.016 0.41 0.032 0.81 0.435 11.05 11.0 6.3 37.0 66.0
25 20 7/28 0.016 0.41 0.032 0.81 0.483 12.27 11.0 6.3 40.0 72.0
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Packaging:
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
ꢀ
*A – Capacitance between conductors
packaging and color options
*B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
Orange/Black
Blue/Black
Black/White
Red/White
COLOR
Blue/Red
Black
White
Red
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Red/Green
Orange/Green
Green
Black/White/Red
White/Black/Red
Red/Black/White
Green/Black/White
Orange
Green/White
Blue/White
Black/Red
Blue
White/Black
Red/Black
Green/Black
White/Red
Orange/Red
69
Electronics
Computer Cable
Multi-Conductor, Foil/Braid Shield
ULꢀ2464,ꢀNECꢀTypeꢀCL2ꢀ(UL)ꢀorꢀCMꢀ(UL)ꢀc(UL),ꢀCSAꢀCMG
Product Construction:
Conductor:
•ꢀꢀ28ꢀandꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
ꢀ
tinned copper per ASTM B-33
Insulation:
NOMINAL
INSULATION
THICKNESS
NOMINAL
JACKET
NOMINAL DCR NOMINAL
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVCꢀ
NOMINAL
O.D.
Ω
/kft
CAP.**
pF/ft
per UL 1061
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
THICKNESS
@20˚C
CATALOG NO. OF AWG COND.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
A
B
Shield:
CL2, CMG, UL 2464
ꢀ
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
3
4
5
6
7
8
9
28 7/36 0.010 0.25 0.032 0.81 0.166 4.22 67.5 5.0 26.0 47.0
28 7/36 0.010 0.25 0.032 0.81 0.176 4.47 67.5 5.0 26.0 47.0
28 7/36 0.010 0.25 0.032 0.81 0.186 4.72 67.5 5.0 26.0 47.0
28 7/36 0.010 0.25 0.032 0.81 0.196 4.98 67.5 5.0 25.0 44.0
28 7/36 0.010 0.25 0.032 0.81 0.196 4.98 67.5 5.0 25.0 44.0
28 7/36 0.010 0.25 0.032 0.81 0.207 5.26 67.5 5.0 25.0 44.0
28 7/36 0.010 0.25 0.032 0.81 0.217 5.51 67.5 5.0 20.0 36.0
C0939A*
C0940A*
C0941A*
C0942A*
C0943A*
C0944A*
C0945A*
C0946A*
C0947A
C0948A
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwireꢀ
(28ꢀAWGꢀonly)
•ꢀꢀ65%ꢀtinnedꢀcopperꢀbraid
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
ꢀ
ꢀ
10 28 7/36 0.010 0.25 0.032 0.81 0.231 5.87 67.5 5.0 20.0 36.0
15 28 7/36 0.010 0.25 0.032 0.81 0.256 6.50 67.5 5.0 20.0 36.0
25 28 7/36 0.010 0.25 0.032 0.81 0.301 7.65 67.5 5.0 20.0 36.0
Applications:
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
CM, CMG, UL 2464
3
4
5
6
7
8
9
24 7/32 0.010 0.25 0.032 0.81 0.186 4.72 25.7 5.3 33.0 59.0
24 7/32 0.010 0.25 0.032 0.81 0.197 5.00 25.7 5.5 33.0 59.0
24 7/32 0.010 0.25 0.032 0.81 0.210 5.33 25.7 4.4 33.0 59.0
24 7/32 0.010 0.25 0.032 0.81 0.223 5.66 25.7 4.6 30.0 55.0
24 7/32 0.010 0.25 0.032 0.81 0.223 5.66 25.7 4.6 30.0 55.0
24 7/32 0.010 0.25 0.032 0.81 0.237 6.02 25.7 3.8 30.0 55.0
24 7/32 0.010 0.25 0.032 0.81 0.250 6.35 25.7 3.9 30.0 55.0
C0951A
C0952A
C0953A
C0954A
C0955A
C0956A
C0957A
C0958A
C0959A
C0960A
C0961A
Features:
•ꢀꢀBraidꢀshieldꢀprovidesꢀgoodꢀflexibility
•ꢀꢀSuperiorꢀshieldingꢀwhereꢀnoiseꢀrejectionꢀ
is critical
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCC Docket 20780 demands
ꢀ
ꢀ
10 24 7/32 0.010 0.25 0.032 0.81 0.267 6.78 25.7 4.2 30.0 55.0
15 24 7/32 0.010 0.25 0.032 0.81 0.298 7.57 25.7 3.6 30.0 55.0
20 24 7/32 0.010 0.25 0.032 0.81 0.325 8.26 25.7 4.5 30.0 55.0
25 24 7/32 0.010 0.25 0.032 0.81 0.355 9.02 25.7 3.5 30.0 55.0
ꢀ
Compliances:
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL2ꢀ-ꢀ28ꢀAWGꢀ
(UL:ꢀ75˚C)
*ColorꢀCodeꢀChartꢀ1.ꢀRemainingꢀitemsꢀColorꢀCodeꢀChartꢀ2
**A – Capacitance between conductors
ꢀ
**B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart 1
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ-ꢀ24ꢀAWGꢀ
(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
NO. OF
COND.
NO. OF
COND.
ꢀ
ꢀ
ꢀ
ꢀ
COLOR
COLOR
Light Blue
Orange
Yellow
Violet
Gray
Black
White
Red
Light Green
Light Brown
1
2
3
4
5
6
7
8
9
10
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Packaging:
Color Code Chart 2 Per ICEA
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
NO. OF
COND.
NO. OF
NO. OF
COND.
packaging and color options
COLOR
COND.
10
11
12
13
14
15
16
17
18
COLOR
COLOR
LightꢀBlue/Red
Red/Green
Black
White
Red
Light Green
Orange
Light Blue
White/Black
Red/Black
Orange/Black
Light Blue/Black
Black/White
1
2
3
4
5
6
7
8
9
19
20
21
22
23
24
25
Orange/Green
Red/White
Black/White/Red
White/Black/Red
Red/Black/White
LightꢀGreen/Black/White
LightꢀGreen/White
LightꢀBlue/White
Black/Red
White/Red
Orange/Red
Light Green/Black
70
Computer Cable
Electronics
Multi-Conductor, Foil/Braid Shield
ULꢀ2464,ꢀNECꢀTypeꢀCMRꢀ(UL)ꢀc(UL),ꢀCSAꢀCMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVCꢀ
NOMINAL
INSULATION
THICKNESS
NOMINAL
JACKET
NOMINAL DCR
NOMINAL
CAP.*
per UL 1061
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL
O.D.
Ω/kft
THICKNESS
@20˚C
pF/ft
CATALOG NO. OF AWG COND.
NUMBER
COND. SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
A
B
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
3
4
5
6
7
8
9
22 7/30 0.010 0.25 0.032 0.81 0.199 5.05 16.6 5.6 36.0 66.0
C0971A
C0972A
C0973A
C0974A
C0975A
C0976A
C0977A
C0978A
C0979A
C0980A
C0981A
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀout
•ꢀꢀ65%ꢀtinnedꢀcopperꢀbraid
22 7/30 0.010 0.25 0.032 0.81 0.212 5.38 16.6 4.4 36.0 66.0
22 7/30 0.010 0.25 0.032 0.81 0.226 5.74 16.6 4.7 36.0 66.0
22 7/30 0.010 0.25 0.032 0.81 0.241 6.12 16.6 3.8 34.0 60.0
22 7/30 0.010 0.25 0.032 0.81 0.241 6.12 16.6 6.2 34.0 60.0
22 7/30 0.010 0.25 0.032 0.81 0.257 6.53 16.6 4.0 34.0 60.0
22 7/30 0.010 0.25 0.032 0.81 0.272 6.91 16.6 3.4 34.0 60.0
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80˚C
Applications:
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
10 22 7/30 0.010 0.25 0.032 0.81 0.291 7.39 16.6 3.6 34.0 60.0
15 22 7/30 0.010 0.25 0.032 0.81 0.326 8.28 16.6 3.6 34.0 60.0
20 22 7/30 0.010 0.25 0.032 0.81 0.357 9.07 16.6 3.9 34.0 60.0
25 22 7/30 0.010 0.25 0.032 0.81 0.391 9.93 16.6 2.7 34.0 60.0
Features:
•ꢀꢀBraidꢀshieldꢀprovidesꢀgoodꢀflexibility
•ꢀꢀSuperiorꢀshieldingꢀwhereꢀnoiseꢀrejectionꢀ
ꢀ
ꢀ
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
is critical
ꢀ
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCC Docket 20780 demands
Color Code Chart Per ICEA
NO. OF
COND.
NO. OF
COND.
NO. OF
COND.
Compliances:
COLOR
COLOR
Orange/Black
Light Blue/Black
Black/White
COLOR
LightꢀBlue/Red
Red/Green
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Black
White
Red
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Orange/Green
Light Green
Orange
Red/White
Black/White/Red
White/Black/Red
Red/Black/White
LightꢀGreen/Black/White
LightꢀGreen/White
LightꢀBlue/White
Black/Red
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Light Blue
Packaging:
White/Black
Red/Black
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
White/Red
Light Green/Black
Orange/Red
71
Electronics
Computer Cable
Multi-Conductor, Foil/Braid Shield, Lo-Cap®
ULꢀ2919,ꢀNECꢀTypeꢀCL2ꢀorꢀCMꢀ(UL)ꢀc(UL)ꢀCMH,ꢀCSAꢀCMH
Product Construction:
Conductor:
•ꢀꢀ28ꢀandꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
ꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀPꢀ remiumꢀgradeꢀfoamedꢀLo-Cap® color
NOM. INSULATION NOM. JACKET
NOMINAL
O.D.
NOMINAL DCR NOMINAL CAP.*
Ω/kft pF/ft
NO.
coded polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
THICKNESS
THICKNESS
CATALOG OF
NUMBER COND. INCHES mm INCHES mm INCHES mm COND. SHLD.
A
B
Shield:
28 AWG (7/36): CL2, CSA CMH
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
3
4
0.016 0.41 0.032 0.81 0.192 4.88 64.9
0.016 0.41 0.032 0.81 0.205 5.21 64.9
0.016 0.41 0.032 0.81 0.218 5.54 64.9
0.016 0.41 0.032 0.81 0.232 5.89 64.9
0.016 0.41 0.032 0.81 0.232 5.89 64.9
0.016 0.41 0.032 0.81 0.247 6.27 64.9
0.016 0.41 0.032 0.81 0.261 6.63 64.9
0.016 0.41 0.032 0.81 0.279 7.09 64.9
0.016 0.41 0.032 0.81 0.312 7.92 64.9
7.8
5.9
5.9
6.2
6.2
4.8
4.9
5.2
4.2
9.5
9.5
9.5
9.0
9.0
9.0
9.0
9.0
9.0
17.0
17.0
17.0
16.0
16.0
16.0
16.0
16.0
16.0
C0530A
C0531A
C0532A
C0533A
C0534A
C0535A
C0536A
C0537A
C0538A
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
•ꢀꢀ70%ꢀtinnedꢀcopperꢀbraid
ꢀ
ꢀ
5
6
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
7
ꢀ
ꢀ
8
9
Applications:
10
15
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀHighꢀspeedꢀcomputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀControlꢀcircuits
•ꢀꢀDesignedꢀforꢀlowꢀcapacitanceꢀ
applications
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀandꢀRS-423ꢀ
CAD/CAM applications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ30ꢀvolts
24 AWG (7/32): CM (UL) c(UL) CMH, AWM Style 2919
3
4
0.016 0.41 0.032 0.81 0.211 5.36 25.7
0.016 0.41 0.032 0.81 0.227 5.77 25.7
0.016 0.41 0.032 0.81 0.242 6.15 25.7
0.016 0.41 0.032 0.81 0.259 6.58 25.7
0.016 0.41 0.032 0.81 0.259 6.58 25.7
0.016 0.41 0.032 0.81 0.276 7.01 25.7
0.016 0.41 0.032 0.81 0.293 7.44 25.7
0.016 0.41 0.032 0.81 0.315 8.00 25.7
0.016 0.41 0.032 0.81 0.354 8.99 25.7
3.8
3.8
3.8
3.2
3.2
3.2
3.6
3.6
3.6
11.9 21.5
11.9 21.5
11.9 21.5
11.2 20.2
11.2 20.2
11.2 20.2
11.2 20.2
11.2 20.2
11.2 20.2
C0680A
C0681A
C0682A
C0683A
C0684A
C0685A
C0686A
C0687A
C0688A
ꢀ
5
6
ꢀ
7
Features:
•ꢀꢀBraidꢀshieldꢀprovidesꢀgoodꢀflexibility
•ꢀꢀSuperiorꢀshieldingꢀwhereꢀnoiseꢀrejectionꢀ
is critical
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCC Docket 20780 demands
8
ꢀ
ꢀ
9
10
15
ꢀ
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Vpꢀ=ꢀ78%
Impedance:ꢀ≈100 Ω
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2919ꢀ(UL:ꢀ80˚C,ꢀ30V)
•ꢀꢀCSAꢀCMHꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Color Code Chart 1 - For cables up to and including 10 conductors
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
Light Blue
Orange
Yellow
Violet
Gray
Black
White
Red
Light Green
Brown
1
2
3
4
5
6
7
8
9
10
ꢀ
•ꢀꢀPassesꢀCSAꢀCMHꢀFlameꢀTest
Packaging:
ꢀ
ꢀ
ꢀ
•ꢀꢀ1000'ꢀ(305ꢀm)ꢀspoolsꢀorꢀreels
•ꢀꢀ500'ꢀ(152ꢀm)ꢀspoolsꢀorꢀreels
•ꢀꢀOtherꢀput-upsꢀavailable—consultꢀ
Customer Service
Color Code Chart 2 Per ICEA - For cables up to 15 conductors
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
Black
White
Red
Light Green
Orange
Light Blue
White/Black
Red/Black
Orange/Black
Light Blue/Black
Black/White
Red/White
LightꢀGreen/White
LightꢀBlue/White
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Light Green/Black
72
Computer Cable
Electronics
Multi-Paired, Foil Shield
ULꢀ2464,ꢀNECꢀTypeꢀCMRꢀ(UL)ꢀc(UL),ꢀCSAꢀCMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVCꢀ
per UL 1061
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL
NOMINAL
JACKET
NOMINAL
CAP.*
pF/ft
INSULATION
NOMINAL NOMINAL DCR
O.D. Ω/kft
NO.
Shield:
THICKNESS THICKNESS
CATALOG
OF AWG COND.
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester
withꢀ25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀ
out
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
A
B
1
2
3
4
5
6
7
8
9
24 7/32 0.010 0.25 0.032 0.81 0.157 3.99 25.7 7.2 19.7 21.5
24 7/32 0.010 0.25 0.032 0.81 0.214 5.44 25.7 7.2 28.7 21.5
24 7/32 0.010 0.25 0.032 0.81 0.225 5.72 25.7 7.2 25.7 21.5
24 7/32 0.010 0.25 0.032 0.81 0.245 6.23 25.7 7.2 25.7 20.2
24 7/32 0.010 0.25 0.032 0.81 0.265 6.73 25.7 7.2 25.7 20.2
24 7/32 0.010 0.25 0.032 0.81 0.287 7.29 25.7 7.2 23.7 42.7
24 7/32 0.010 0.25 0.032 0.81 0.287 7.29 25.7 7.2 23.7 42.7
24 7/32 0.010 0.25 0.032 0.81 0.309 7.85 25.7 7.2 23.7 42.7
24 7/32 0.010 0.25 0.032 0.81 0.331 8.41 25.7 7.2 23.7 42.7
C0600A
C0601A
C0602A
C0603A
C0604A
C0605A
C0606A
C0607A
C0608A
C0609A
C0610A
C0611A
C0612A
C0720A
C0721A
C0722A
C0723A
C0724A
C0725A
C0726A
C0728A
C0729A
C0730A
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
ꢀ
ꢀ
Applications:
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
10 24 7/32 0.010 0.25 0.032 0.81 0.359 9.12 25.7 7.2 23.7 42.7
15 24 7/32 0.010 0.25 0.032 0.81 0.410 10.41 25.7 7.2 23.7 42.7
19 24 7/32 0.010 0.25 0.032 0.81 0.432 10.97 25.7 7.2 23.7 42.7
25 24 7/32 0.010 0.25 0.032 0.81 0.505 12.84 25.7 7.2 23.7 42.7
Features:
•ꢀꢀSuperiorꢀshieldingꢀwhereꢀnoiseꢀrejectionꢀ
1
2
3
4
5
6
9
22 7/30 0.010 0.25 0.032 0.81 0.169 4.29 16.6 6.2 40.4 72.6
22 7/30 0.010 0.25 0.032 0.81 0.234 5.94 16.6 6.2 32.3 58.1
22 7/30 0.010 0.25 0.032 0.81 0.246 6.25 16.6 6.2 27.8 50.1
22 7/30 0.010 0.25 0.032 0.81 0.269 6.83 16.6 6.2 27.8 50.1
22 7/30 0.010 0.25 0.032 0.81 0.292 7.42 16.6 6.2 27.8 50.1
22 7/30 0.010 0.25 0.032 0.81 0.317 8.05 16.6 6.2 25.5 45.9
22 7/30 0.010 0.25 0.032 0.81 0.367 9.32 16.6 6.2 25.5 45.9
ꢀ
is critical
ꢀ
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCC Docket 20780 demands
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA,ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
15 22 7/30 0.010 0.25 0.032 0.81 0.457 11.62 16.6 6.2 25.5 45.9
19 22 7/30 0.010 0.25 0.032 0.81 0.482 12.24 16.6 6.2 25.5 45.9
27 22 7/30 0.010 0.25 0.032 0.81 0.576 14.36 16.6 6.2 26.0 46.0
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Color Code Chart
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
NO. OF
PAIRS
NO. OF
PAIRS
packaging and color options
COLOR
COLOR
BlackꢀwithꢀRed
BlackꢀwithꢀWhite
Black with Green
Black with Blue
Black with Yellow
Black with Brown
Black with Orange
RedꢀwithꢀWhite
RedꢀwithꢀGreen
RedꢀwithꢀBlue
GreenꢀwithꢀWhite
Green with Blue
Green with Yellow
Green with Brown
Green with Orange
WhiteꢀwithꢀBlue
WhiteꢀwithꢀYellow
WhiteꢀwithꢀBrown
WhiteꢀwithꢀOrange
Blue with Yellow
Blue with Brown
Blue with Orange
Brown with Yellow
Brown with Orange
1
2
14
15
16
17
18
19
20
21
22
23
24
25
26
27
3
4
5
6
7
8
9
10
11
12
13
RedꢀwithꢀYellow
RedꢀwithꢀBrown
RedꢀwithꢀOrange
73
Electronics
Computer Cable
Multi-Paired, Foil Shield, Lo-Cap®
ULꢀ2448,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL),ꢀCMH
Product Construction:
Conductor:
ꢀ
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polyethylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
NOM.
NOMINAL
DCR
NOMINAL
CAP.*
Shield:
VEL.
INSULATION JACKET
THICKNESS THICKNESS
NOMINAL
O.D.
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester
withꢀ25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀ
out
NO.
OF NOM.
PROP., IMP.,
Ω/kft
pF/ft
CATALOG OF AWG COND.
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
%
Ω
A
B
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
2
3
4
5
6
9
24
24
24
24
24
24
7/32
7/32
7/32
7/32
7/32
7/32
7/32
0.015 0.38 0.032 0.81 0.247 6.27 25.7 7.20
0.015 0.38 0.032 0.81 0.261 6.63 25.7 7.20
0.015 0.38 0.032 0.81 0.277 7.04 25.7 7.20
0.015 0.38 0.032 0.81 0.310 7.87 25.7 7.20
0.015 0.38 0.032 0.81 0.336 8.53 25.7 7.20
0.015 0.38 0.032 0.81 0.391 9.93 25.7 7.20
0.015 0.38 0.032 0.97 0.459 11.66 25.7 7.20
66
66
66
66
66
66
66
100 14.4 26.0
100 13.9 25.1
100 13.9 25.1
100 13.9 25.1
100 13.0 23.4
100 13.0 23.4
100 13.0 23.4
C0890A
C0901A
C0893A
C0894A
C0899A
C0896A
C0897A
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+75°C
Applications:
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀSuitableꢀforꢀlowꢀcapacitanceꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ30ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
12.5 24
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2448ꢀ(UL:ꢀ60˚C,ꢀ30V)
•ꢀꢀCSAꢀCMHꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Color Code Chart
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
BlackꢀpairedꢀwithꢀWhite
RedꢀpairedꢀwithꢀGreen
Brown paired with Blue
Orange paired with Yellow
VioletꢀpairedꢀwithꢀGray
Tan paired with Pink
White/BlueꢀpairedꢀwithꢀBlue/White
White/BrownꢀpairedꢀwithꢀBrown/White
White/OrangeꢀpairedꢀwithꢀOrange/White
White/GreenꢀpairedꢀwithꢀGreen/White
White/RedꢀpairedꢀwithꢀRed/White
White/BlackꢀpairedꢀwithꢀBlack/White
1
2
3
4
5
6
7
8
9
10
11
12
ꢀ
•ꢀꢀPassesꢀCSAꢀCMHꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
SingleꢀConductor:ꢀGreenꢀWithꢀYellowꢀStripe
74
Computer Cable
Electronics
Multi-Paired, Foil/Braid Shield
ULꢀ2464,ꢀNECꢀTypeꢀCMRꢀ(UL)ꢀc(UL),ꢀCSAꢀCMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀandꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVCꢀ
per UL 1061
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL
INSULATION
THICKNESS
NOMINAL
JACKET
NOMINAL
NOMINAL
CAP.*
Shield:
NOMINAL
O.D.
DCR
NO.
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester
withꢀ25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀ
out
THICKNESS
Ω/kft
pF/ft
CATALOG
OF AWG COND.
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
A
B
•ꢀꢀ65%ꢀtinnedꢀcopperꢀbraid
2
3
4
5
6
7
8
24 7/32 0.010 0.25 0.032 0.81 0.235 5.97 25.7 5.4 29.5 53.0
C0620A
C0621A
C0622A
C0623A
C0624A
C0625A
C0626A
C0628A
C0630A
C0650A
C0651A
C0652A
C0653A
C0654A
C0655A
C0656A
C0658A
C0660A
C0663A
24 7/32 0.010 0.25 0.032 0.81 0.231 5.87 25.7 5.0 26.4 47.6
24 7/32 0.010 0.25 0.032 0.81 0.253 6.43 25.7 4.5 26.4 47.6
24 7/32 0.010 0.25 0.032 0.81 0.278 7.06 25.7 4.6 26.4 47.6
24 7/32 0.010 0.25 0.032 0.81 0.296 7.52 25.7 2.9 24.4 43.9
24 7/32 0.010 0.25 0.032 0.81 0.313 7.95 25.7 3.1 24.4 43.9
24 7/32 0.010 0.25 0.032 0.81 0.336 8.53 25.7 4.1 24.4 43.9
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
ꢀ
ꢀ
Applications:
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
10 24 7/32 0.010 0.25 0.032 0.81 0.357 9.07 25.7 2.6 24.4 43.9
12.5 24 7/32 0.010 0.25 0.032 0.81 0.386 9.80 25.7 3.6 24.4 43.9
2
3
4
5
6
7
8
22 7/30 0.010 0.25 0.032 0.81 0.229 5.82 16.6 3.8 33.2 59.7
22 7/30 0.010 0.25 0.032 0.81 0.296 7.52 16.6 4.1 28.6 51.5
22 7/30 0.010 0.25 0.032 0.81 0.320 8.13 16.6 3.5 28.6 51.5
22 7/30 0.010 0.25 0.032 0.81 0.331 8.41 16.6 3.9 28.6 51.5
22 7/30 0.010 0.25 0.032 0.81 0.348 8.84 16.6 4.4 26.2 47.2
22 7/30 0.010 0.25 0.032 0.81 0.348 8.84 16.6 5.0 26.2 47.2
22 7/30 0.010 0.25 0.032 0.81 0.368 9.35 16.6 3.8 26.2 47.2
Features:
•ꢀꢀBraidꢀshieldꢀprovidesꢀgoodꢀflexibility
•ꢀꢀSuperiorꢀshieldingꢀwhereꢀnoiseꢀrejectionꢀ
is critical
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCC Docket 20789 demands
ꢀ
ꢀ
ꢀ
10 22 7/30 0.010 0.25 0.032 0.81 0.388 9.86 16.6 4.1 26.2 47.2
12.5 22 7/30 0.010 0.25 0.032 0.81 0.429 10.90 16.6 4.7 26.2 47.2
25 22 7/30 0.010 0.25 0.058 0.81 0.620 15.75 16.6 2.1 26.2 46.0
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
Black paired with Yellow
Black paired with Brown
Black paired with Orange
RedꢀpairedꢀwithꢀWhite
RedꢀpairedꢀwithꢀGreen
RedꢀpairedꢀwithꢀBlue
RedꢀpairedꢀwithꢀYellow
RedꢀpairedꢀwithꢀBrown
RedꢀpairedꢀwithꢀOrange
WhiteꢀpairedꢀwithꢀGreen
Blue paired with Green
Yellow paired with Green
Brown paired with Green
Orange paired with Green
WhiteꢀpairedꢀwithꢀBlue
WhiteꢀpairedꢀwithꢀYellow
WhiteꢀpairedꢀwithꢀBrown
WhiteꢀpairedꢀwithꢀOrange
Yellow paired with Blue
Blue paired with Brown
Orange paired with Blue
1
2
3
4
5
6
7
8
9
13
14
15
16
17
18
19
20
21
22
23
24
25
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
10
11
12
SingleꢀConductor:ꢀGreenꢀwithꢀYellowꢀStripe
75
Electronics
Computer Cable
Multi-Paired, Foil/Braid Shield, Lo-Cap®
ULꢀ2919,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL)ꢀCMH
Product Construction:
Conductor:
ꢀ
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polyethylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
NOM.
NOM.
NOMINAL
DCR
NOMINAL
CAP.*
Shield:
VEL.
INSULATION JACKET
THICKNESS THICKNESS
NOMINAL
O.D.
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
NO.
OF NOM.
PROP., IMP.,
ꢀ
Ω/kft
pF/ft
CATALOG OF AWG COND.
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
•ꢀꢀ90%ꢀtinnedꢀcopperꢀbraid
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
%
Ω
A
B
ꢀ
ꢀ
1
2
3
4
24
24
24
24
7/32 0.024 0.61 0.032 0.81 0.235 5.97 25.7 2.9
7/32 0.024 0.61 0.032 0.81 0.304 7.72 25.7 2.3
7/32 0.024 0.61 0.032 0.81 0.360 9.14 25.7 2.3
7/32 0.024 0.61 0.032 0.81 0.390 9.91 25.7 2.1
66 120 14.6 26.2
66 120 11.7 21.0
66 120 11.9 21.4
66 120 11.9 21.4
C0841A
C0842A
C0843A
C0844A
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
ꢀ
ꢀ
Applications:
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
*A – Capacitance between conductors
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
*B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart 1
•ꢀꢀControlꢀcircuits
NO. OF
PAIRS
•ꢀꢀLowꢀcapacitanceꢀrequirements
•ꢀꢀSuitableꢀforꢀEIAꢀRS-485ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ30ꢀvolts
COLOR
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
1
2
3
4
Features:
•ꢀꢀBraidꢀshieldꢀprovidesꢀgoodꢀflexibility
•ꢀꢀSuperiorꢀshieldingꢀwhereꢀnoiseꢀrejectionꢀ
ꢀ
ꢀ
is critical
ꢀ
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCC Docket 20789 demands
NOM.
NOM.
NOMINAL
DCR
NOMINAL
VEL.
Compliances:
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCM/CMHꢀ
(UL:ꢀ75°C)
INSULATION JACKET
THICKNESS THICKNESS
NOMINAL
O.D.
CAP.*
NO.
CATALOG OF AWG COND.
OF NOM.
ꢀ
Ω/kft
pF/ft
PROP., IMP.,
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
%
Ω
A
B
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀStyleꢀ2919ꢀ(UL:ꢀ80˚C,ꢀ30V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
1
2
3
4
24
24
24
24
7/32 0.024 0.61 0.032 0.81 0.235 5.97 25.7 2.9
7/32 0.024 0.61 0.032 0.81 0.304 7.72 25.7 2.3
7/32 0.024 0.61 0.032 0.81 0.360 9.14 25.7 2.3
7/32 0.024 0.61 0.032 0.81 0.390 9.91 25.7 2.1
66 120 14.6 26.2
66 120 11.7 21.0
66 120 11.9 21.4
66 120 11.9 21.4
C4841A
C4842A
C4843A
C4844A
ꢀ
•ꢀꢀPassesꢀCSAꢀCMHꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart 2
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
White–BlueꢀStripe
Blue–WhiteꢀStripe
White–OrangeꢀStripe
Orange–WhiteꢀStripe
White–GreenꢀStripe
Green–WhiteꢀStripe
White–BrownꢀStripe
Brown–WhiteꢀStripe
1
2
3
4
76
Computer Cable
Electronics
Multi-Paired, Foil/Braid Shield, Lo-Cap®
ULꢀ2919,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL)ꢀCMH
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polyethylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
NOM.
NOMINAL
DCR
NOMINAL
Shield:
VEL.
INSULATION JACKET
THICKNESS THICKNESS
NOMINAL
O.D.
CAP.*
pF/ft
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester
withꢀ25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀ
out
NO.
OF NOM.
ꢀ
Ω
/kft
CATALOG OF AWG COND.
PROP., IMP.,
%
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
Ω
A
B
ꢀ
ꢀ
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
•ꢀꢀ90%ꢀtinnedꢀcopperꢀbraid
2
3
24
24
24
24
24
24
24
24
7/32 0.015 0.38 0.032 0.81 0.257 6.53 25.7 2.7
7/32 0.015 0.38 0.032 0.81 0.289 7.34 25.7 2.6
7/32 0.015 0.38 0.032 0.81 0.313 7.95 25.7 3.2
7/32 0.015 0.38 0.032 0.81 0.338 8.59 25.7 1.9
7/32 0.015 0.38 0.032 0.81 0.364 9.24 25.7 2.4
7/32 0.015 0.38 0.032 0.81 0.364 9.24 25.7 2.0
7/32 0.015 0.38 0.038 0.97 0.462 11.73 25.7 1.7
7/32 0.015 0.38 0.038 0.97 0.479 12.17 25.7 1.8
66 100 14.8 26.7
66 100 14.2 25.5
66 100 14.2 25.5
66 100 14.2 25.5
66 100 13.2 23.8
66 100 13.2 23.8
66 100 13.2 23.8
66 100 13.2 23.8
C0829A
C0830A
C0831A
C0832A
C0839A
C0833A
C0835A
C0836A
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
4
ꢀ
ꢀ
5
Applications:
6
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
•ꢀꢀControlꢀcircuits
•ꢀꢀLowꢀcapacitanceꢀrequirements
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuitableꢀforꢀEIAꢀRS-422ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ30ꢀvolts
7
10
12
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart
Features:
ꢀ
•ꢀꢀBraidꢀshieldꢀprovidesꢀgoodꢀflexibility
NO. OF
COND.
NO. OF
COND.
COLOR
COLOR
ꢀ
•ꢀꢀSuperiorꢀshieldingꢀwhereꢀnoiseꢀrejectionꢀ
is critical
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
Black paired with Yellow
Black paired with Brown
Black paired with Orange
RedꢀpairedꢀwithꢀWhite
RedꢀpairedꢀwithꢀGreen
RedꢀpairedꢀwithꢀBlue
RedꢀpairedꢀwithꢀYellow
RedꢀpairedꢀwithꢀBrown
1
2
3
4
5
6
7
8
9
10
11
12
ꢀ
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCC Docket 20789 demands
Compliances:
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCM/CMHꢀ
(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2919ꢀ(UL:ꢀ80˚C,ꢀ30V)
•ꢀꢀCSAꢀCMHꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
ꢀ
•ꢀꢀPassesꢀCSAꢀCMHꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
77
Electronics
Computer Cable
Multi-Paired, Foil/Braid Shield, Lo-Cap®
ULꢀ2919,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL)ꢀCMH
Product Construction:
Conductor:
ꢀ
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀLo-Cap®
foamed polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
NOM.
NOMINAL
DCR
NOMINAL
CAP.*
Shield:
VEL.
INSULATION JACKET
THICKNESS THICKNESS
NOMINAL
O.D.
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
NO.
OF NOM.
PROP., IMP.,
ꢀ
Ω/kft
pF/ft
CATALOG OF AWG COND.
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
•ꢀꢀ65%ꢀtinnedꢀcopperꢀbraid
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
%
Ω
A
B
ꢀ
ꢀ
2
3
24
24
24
24
24
24
24
24
7/32 0.016 0.41 0.032 0.81 0.276 7.01 25.7 3.0
7/32 0.016 0.41 0.032 0.81 0.290 7.37 25.7 3.2
7/32 0.016 0.41 0.032 0.81 0.315 8.00 25.7 3.3
7/32 0.016 0.41 0.032 0.81 0.340 8.64 25.7 4.2
7/32 0.016 0.41 0.032 0.81 0.368 9.35 25.7 3.6
7/32 0.016 0.41 0.032 0.81 0.370 9.40 25.7 3.5
7/32 0.016 0.41 0.032 0.81 0.397 10.08 25.7 2.7
7/32 0.016 0.41 0.038 0.97 0.473 12.01 25.7 2.4
7/32 0.016 0.41 0.038 0.97 0.486 12.34 25.7 2.4
7/32 0.016 0.41 0.048 1.22 0.555 14.10 25.7 2.6
7/32 0.016 0.41 0.048 1.22 0.585 14.86 25.7 2.1
7/32 0.016 0.41 0.048 1.22 0.677 17.20 25.7 2.0
78
78
78
78
78
78
78
78
78
78
78
78
132 10.2 18.4
132 9.9 17.8
132 9.9 17.8
132 9.9 17.8
141 9.2 16.6
141 9.2 16.6
141 9.2 16.6
141 9.2 16.6
141 9.2 16.6
141 9.2 16.6
141 9.2 16.6
141 9.2 16.6
C0515A
C0516A
C0517A
C0518A
C0519A
C0520A
C0521A
C0522A
C0523A
C0524A
C0525A
C0526A
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
ꢀ
ꢀ
4
5
Applications:
•ꢀꢀHigh-speedꢀcomputerꢀinterconnects
•ꢀꢀCAD/CAMꢀsystems
•ꢀꢀEIAꢀRS-232ꢀandꢀRS-423ꢀsystems
•ꢀꢀControlꢀcircuits
•ꢀꢀIndustrialꢀequipment
•ꢀꢀLowꢀsignalꢀdistortionꢀdataꢀrequirements
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ30ꢀvolts
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
6
7
8
10
12.5 24
15
18
25
24
24
24
Features:
•ꢀꢀBraidꢀshieldꢀprovidesꢀgoodꢀflexibility
•ꢀꢀSuperiorꢀshieldingꢀwhereꢀnoiseꢀrejectionꢀ
is critical
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCC Docket 20789 demands
ꢀ
ꢀ
*A – Capacitance between conductors
ꢀ
*B – Capacitance between one conductor and other conductors connected to shield
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCM/CMHꢀ
(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2919ꢀ(UL:ꢀ80°C,ꢀ30V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Color Code Chart
NO. OF
PAIRS
NO. OF
PAIRS
NO. OF
PAIRS
ꢀ
ꢀ
ꢀ
COLOR
COLOR
Red–GrayꢀStripe
Gray–RedꢀStripe
COLOR
Yellow–Green Stripe
Green–Yellow Stripe
Yellow–Brown Stripe
Brown–Yellow Stripe
Yellow–Gray Stripe
Gray–Yellow Stripe
Violet–BlueꢀStripe
Blue–VioletꢀStripe
Violet–OrangeꢀStripe
Orange–VioletꢀStripe
Violet–GreenꢀStripe
Green–VioletꢀStripe
Violet–BrownꢀStripe
Brown–VioletꢀStripe
Violet–GrayꢀStripe
Gray–VioletꢀStripe
White–BlueꢀStripe
Blue–WhiteꢀStripe
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
White–OrangeꢀStripe
Orange–WhiteꢀStripe
Black–Blue Stripe
Blue–Black Stripe
Packaging:
ꢀ
White–GreenꢀStripe
Green–WhiteꢀStripe
Black–Orange Stripe
Orange–Black Stripe
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
White–BrownꢀStripe
Brown–WhiteꢀStripe
Black–Green Stripe
Green–Black Stripe
White–GrayꢀStripe
Gray–WhiteꢀStripe
Black–Brown Stripe
Brown–Black Stripe
Red–BlueꢀStripe
Blue–RedꢀStripe
Black–Gray Stripe
Gray–Black Stripe
Red–OrangeꢀStripe
Orange–RedꢀStripe
Yellow–Blue Stripe
Blue–Yellow Stripe
Red–GreenꢀStripe
Green–RedꢀStripe
Yellow–Orange Stripe
Orange–Yellow Stripe
Red–BrownꢀStripe
Brown–RedꢀStripe
SingleꢀConductor:ꢀGreenꢀwithꢀYellowꢀStripe
78
Computer Cable
Electronics
Multi-Paired, Foil/Braid Shield, Lo-Cap®
UL 2960, NEC Type CL2
Product Construction:
Conductor:
ꢀ
•ꢀꢀ28ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
NOM.
NOMINAL
DCR
NOMINAL
Shield:
VEL.
INSULATION JACKET
THICKNESS THICKNESS
NOMINAL
O.D.
CAP.*
pF/ft
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
NO.
OF NOM.
ꢀ
Ω
/kft
CATALOG OF AWG COND.
PROP., IMP.,
%
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀout
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
•ꢀꢀ90%ꢀtinnedꢀcopperꢀbraid
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
Ω
A
B
ꢀ
ꢀ
2
3
28
28
28
28
28
28
28
28
7/36 0.009 0.23 0.032 0.81 0.194 4.93 67.5 4.0
7/36 0.009 0.23 0.032 0.81 0.194 4.93 67.5 4.2
7/36 0.009 0.23 0.032 0.81 0.211 5.36 67.5 3.3
7/36 0.009 0.23 0.032 0.81 0.226 5.74 67.5 3.5
7/36 0.009 0.23 0.032 0.81 0.253 6.43 67.5 2.9
7/36 0.009 0.23 0.032 0.81 0.286 7.26 67.5 2.9
7/36 0.009 0.23 0.032 0.81 0.285 7.24 67.5 2.9
7/36 0.009 0.23 0.032 0.81 0.294 7.47 67.5 3.3
66 100 14.8 26.6
66 100 14.0 25.3
66 100 14.0 25.3
66 100 14.0 25.3
66 100 13.1 23.5
66 100 13.1 23.5
66 100 13.1 23.5
66 100 13.1 23.5
C0804A
C0805A
C0806A
C0807A
C0808A
C0809A
C0810A
C0812A
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
ꢀ
ꢀ
4
5
Applications:
•ꢀꢀComputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀDataꢀtransmission
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
7
9
10
12
•ꢀꢀControlꢀcircuits
•ꢀꢀLowꢀcapacitanceꢀrequirements
•ꢀꢀSuitableꢀforꢀEIAꢀRS-232ꢀapplications
•ꢀꢀSuitableꢀforꢀEIAꢀRS-422ꢀapplications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ30ꢀvolts
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Features:
Color Code Chart
ꢀ
•ꢀꢀBraidꢀshieldꢀprovidesꢀgoodꢀflexibility
NO. OF
COND.
NO. OF
COND.
ꢀ
•ꢀꢀSuperiorꢀshieldingꢀwhereꢀnoiseꢀrejectionꢀ
is critical
COLOR
COLOR
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Gren
Black paired with Blue
Black paired with Yellow
Black paired with Brown
Black paired with Orange
RedꢀpairedꢀwithꢀWhite
RedꢀpairedꢀwithꢀGreen
RedꢀpairedꢀwithꢀBlue
RedꢀpairedꢀwithꢀYellow
RedꢀpairedꢀwithꢀBrown
1
2
3
4
5
6
7
8
9
10
11
12
ꢀ
•ꢀꢀAssistsꢀsystemꢀdesignersꢀinꢀmeetingꢀ
FCC Docket 20789 demands
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL2ꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2960ꢀ(UL:ꢀ60°C,ꢀ30V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
79
Electronics
Computer Cable
Multi-Paired, Individually Foil Shielded
NECꢀTypeꢀCL2ꢀandꢀCMꢀ(UL)ꢀc(UL)
Product Construction:
Conductor:
ꢀ
ꢀ
•ꢀꢀ20ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcolor-codedꢀ
polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Shield:
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
pF/ft
NOMINAL O.D.
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairs
CATALOG NO. OF AWG COND.
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀinꢀ
A
B
4
20
7/28
0.015 0.38 0.032 0.81 0.364 9.25 23.0 41.5
C1368A
ꢀ
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwireꢀeachꢀ
pair
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+75°C
Color Code Chart
Applications:
NO. OF
PAIRS
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀApplicationsꢀforꢀtotalꢀisolationꢀofꢀsignalꢀ
•ꢀꢀComputers
•ꢀꢀControlꢀcircuits
•ꢀꢀIndustrialꢀequipment
COLOR
RedꢀpairedꢀwithꢀWhite/Red
BlackꢀpairedꢀwithꢀWhite/Black
GreenꢀpairedꢀwithꢀWhite/Green
WhiteꢀpairedꢀwithꢀWhite/Yellow
1
2
3
4
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Features:
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀforꢀexcellentꢀ
signal isolation
ꢀ
ꢀ
•ꢀꢀExcellentꢀhighꢀfrequencyꢀproperties
•ꢀꢀMechanicalꢀdurability
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL2ꢀ(UL:ꢀ75°C,ꢀ
150V)
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C,ꢀ
300V)
ꢀ
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
80
Computer Cable
Electronics
Multi-Paired, Individually Foil Shielded
ULꢀ2464,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL),ꢀCSAꢀCMG
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀsolidꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Shield:
NOM.
NOM.
NOMINAL
DCR
NOMINAL
CAP.*
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairs
INSULATION JACKET
THICKNESS THICKNESS
NOMINAL
O.D.
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀin
•ꢀꢀSolidꢀtinnedꢀcopperꢀdrainꢀwireꢀeachꢀpair
NOMINAL
Ω/kft
pF/ft
CATALOG NO. OF AWG COND.
IMPEDANCE
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
Ω
A
B
ꢀ
3
6
22 Solid 0.015 0.38 0.032 0.81 0.304 7.72 16.5 11.3
22 Solid 0.015 0.38 0.032 0.81 0.397 10.08 16.5 11.3
50
50
38.6 69.4
38.6 69.4
C6035A
C6036A
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀApplicationsꢀforꢀtotalꢀisolationꢀofꢀsignal
•ꢀꢀComputers
•ꢀꢀControlꢀcircuits
•ꢀꢀIndustrialꢀequipment
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Color Code Chart
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
Black paired with Yellow
Black paired with Brown
1
2
3
4
5
6
Features:
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀforꢀexcellentꢀ
signal isolation
ꢀ
ꢀ
•ꢀꢀExcellentꢀhigh-frequencyꢀproperties
•ꢀꢀMechanicalꢀdurability
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75˚C)
•ꢀꢀULꢀStyleꢀ2464ꢀ(UL:ꢀ80˚C,ꢀ300V)
•ꢀꢀCSAꢀCMGꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
ꢀ
•ꢀꢀPassesꢀCSAꢀCMGꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
81
Electronics
Computer Cable
Multi-Paired, Individually Foil Shielded
ULꢀ2919,ꢀNECꢀTypeꢀCM,ꢀCSAꢀCMH
Product Construction:
Conductor:
ꢀ
ꢀ
•ꢀꢀ24ꢀthruꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
•ꢀꢀTwistedꢀpairsꢀ
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcolor-codedꢀ
polyethylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelowꢀ
Shield:
NOM.
NOM.
NOMINAL
DCR
NOMINAL
CAP.**
pF/ft
VEL.
INSULATION JACKET
THICKNESS THICKNESS
NOMINAL
O.D.
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairs
OF NOM.
PROP., IMP.,
Ω/kft
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀinꢀ
CATALOG NO. OF AWG COND.
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
%
Ω
A
B
ꢀ
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwireꢀeachꢀ
pair
3
6
24
24
24
22
22
22
22
22
22
22
22
22
20
20
20
20
20
7/32 0.011 0.28 0.032 0.81 0.269 6.83 26.0 18.0 66
71 21.7 39.0
71 21.7 39.0
71 21.7 39.0
63 24.4 43.9
63 24.4 43.9
63 24.4 43.9
63 24.4 43.9
63 24.4 43.9
63 24.4 43.9
63 24.4 43.9
63 24.4 43.9
63 24.4 43.9
61 25.3 45.6
61 25.3 45.6
61 25.3 45.6
61 25.3 45.6
61 25.3 45.6
60 25.7 46.2
60 25.7 46.2
60 25.7 46.2
60 25.7 46.2
60 25.7 46.2
C6065A
C6066A
C6067A
C6040A
C6041A
C6042A
C6043A
C6059A
C6044A
C6060A
C6045A
C6046A*
C6052A
C6053A
C6054A
C6056A
C6058A
C6047A
C6048A
C6049A
C6050A
C6051A
7/32 0.011 0.28 0.032 0.81 0.349 8.86 26.0 18.0 66
7/32 0.011 0.28 0.032 0.81 0.406 10.31 26.0 18.0 66
7/30 0.011 0.28 0.032 0.81 0.292 7.42 16.5 11.3 66
7/30 0.011 0.28 0.032 0.81 0.381 9.68 16.5 11.3 66
7/30 0.011 0.28 0.032 0.81 0.445 11.30 16.5 11.3 66
7/30 0.011 0.28 0.032 0.81 0.486 12.34 16.5 11.3 66
7/30 0.011 0.28 0.048 1.22 0.533 13.54 16.5 11.3 66
7/30 0.011 0.28 0.048 1.22 0.591 15.01 16.5 11.3 66
7/30 0.011 0.28 0.048 1.22 0.622 15.80 16.5 11.3 66
7/30 0.011 0.28 0.048 1.22 0.622 15.80 16.5 11.3 66
7/30 0.011 0.28 0.048 1.22 0.696 17.68 16.5 11.3 66
7/28 0.013 0.33 0.032 0.81 0.339 8.61 10.5 10.2 66
7/28 0.013 0.33 0.032 0.81 0.446 11.33 10.5 10.2 66
7/28 0.013 0.33 0.048 1.22 0.555 14.10 10.5 10.2 66
7/28 0.013 0.33 0.048 1.22 0.623 15.82 10.5 10.2 66
7/28 0.013 0.33 0.048 1.22 0.692 17.58 10.5 10.2 66
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+80˚C
9
ꢀ
ꢀ
3
6
Applications:
9
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀApplicationsꢀforꢀtotalꢀisolationꢀofꢀsignal
•ꢀꢀComputers
•ꢀꢀControlꢀcircuits
•ꢀꢀIndustrialꢀequipment
11
12
15
17
19
27
3
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ30ꢀvolts
Features:
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀforꢀexcellentꢀ
signal isolation
•ꢀꢀExcellentꢀhighꢀfrequencyꢀproperties
•ꢀꢀMechanicalꢀdurability
6
ꢀ
ꢀ
9
12
15
3
Compliances:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ(UL:ꢀ75°C)
•ꢀꢀULꢀStyleꢀ2919ꢀ(UL:ꢀ80˚C,ꢀ30V)
•ꢀꢀCSAꢀCMHꢀ(CSA:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
18 16/30 0.016 0.41 0.032 0.81 0.395 10.03 7.2
18 16/30 0.016 0.41 0.048 1.22 0.556 14.12 7.2
18 16/30 0.016 0.41 0.048 1.22 0.649 16.48 7.2
18 16/30 0.016 0.41 0.048 1.22 0.731 18.57 7.2
18 16/30 0.016 0.41 0.048 1.22 0.776 19.71 7.2
8.3
8.3
8.3
8.3
8.3
66
66
66
66
66
6
9
12
15
ꢀ
•ꢀꢀPassesꢀCSAꢀCMHꢀFlameꢀTest
*ULꢀ2919,ꢀCSAꢀCMHꢀOnly
**A – Capacitance between conductors
**B – Capacitance between one conductor and other conductors connected to shield
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart
NO. OF
PAIRS
NO. OF
PAIRS
NO. OF
PAIRS
COLOR
COLOR
COLOR
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
Black paired with Yellow
Black paired with Brown
Black paired with Orange
RedꢀpairedꢀwithꢀWhite
RedꢀpairedꢀwithꢀGreen
RedꢀpairedꢀwithꢀBlue
RedꢀpairedꢀwithꢀYellow
RedꢀpairedꢀwithꢀBrown
RedꢀpairedꢀwithꢀOrange
GreenꢀpairedꢀwithꢀWhite
Green paired with Blue
Green paired with Yellow
Green paired with Brown
Green paired with Orange
WhiteꢀpairedꢀwithꢀBlue
WhiteꢀpairedꢀwithꢀYellow
WhiteꢀpairedꢀwithꢀBrown
WhiteꢀpairedꢀwithꢀOrange
Blue paired with Yellow
Blue paired with Brown
Blue paired with Orange
Brown paired with Yellow
Brown paired with Orange
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
82
Computer Cable
Electronics
Multi-Paired, Individually Foil Shielded, Lo-Cap®
ULꢀ2493,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL)ꢀCMH
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀfoamedꢀ
Lo-Cap® polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
NOM.
NOMINAL
DCR
NOMINAL
Shield:
VEL.
INSULATION JACKET
THICKNESS THICKNESS
NOMINAL
O.D.
CAP.*
pF/ft
NO.
OF NOM.
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairs
Ω/kft
CATALOG OF AWG COND.
PROP., IMP.,
%
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀinꢀ
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm COND. SHLD.
Ω
A
B
ꢀ
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwireꢀeachꢀ
pair
2
3
4
6
9
24
24
24
24
24
7/32 0.022 0.56 0.047 1.19 0.283 7.19 26.0 18.0 78 100 14.8 26.7
7/32 0.022 0.56 0.048 1.22 0.381 9.68 26.0 18.0 78 100 14.8 26.7
7/32 0.022 0.56 0.048 1.22 0.416 10.57 26.0 18.0 78 100 14.8 26.7
7/32 0.022 0.56 0.048 1.22 0.492 12.50 26.0 18.0 78 100 14.8 26.7
7/32 0.022 0.56 0.063 1.60 0.601 15.27 26.0 18.0 78 100 14.8 26.7
7/32 0.022 0.56 0.063 1.60 0.652 16.56 26.0 18.0 78 100 14.8 26.7
7/32 0.022 0.56 0.063 1.60 0.672 17.08 26.0 18.0 78 100 14.8 26.7
7/32 0.022 0.56 0.063 1.60 0.743 18.87 26.0 18.0 78 100 14.8 26.7
C0910A
C0911A
C0912A
C0913A
C0914A
C0915A
C0916A
C0917A
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+75˚C
ꢀ
ꢀ
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀHigh-speedꢀcomputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀControlꢀcircuits
•ꢀꢀSuitableꢀforꢀlowꢀcapacitanceꢀapplications
•ꢀꢀSuitableꢀforꢀEIAꢀRS-422ꢀCAD/CAMꢀ
applications
11 24
12 24
15 24
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Features:
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀforꢀexcellentꢀ
Color Code Chart
signal isolation
NO. OF
PAIRS
NO. OF
PAIRS
ꢀ
ꢀ
•ꢀꢀExcellentꢀhigh-frequencyꢀproperties
•ꢀꢀMechanicalꢀdurability
COLOR
COLOR
BlackꢀpairedꢀwithꢀRed
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
Black paired with Yellow
Black paired with Brown
Black paired with Orange
RedꢀpairedꢀwithꢀWhite
RedꢀpairedꢀwithꢀGreen
RedꢀpairedꢀwithꢀBlue
RedꢀpairedꢀwithꢀYellow
RedꢀpairedꢀwithꢀBrown
RedꢀpairedꢀwithꢀOrange
GreenꢀpairedꢀwithꢀWhite
Green paired with Blue
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCM/CMHꢀ
(UL:ꢀ75˚C,ꢀ300V)
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀStyleꢀ2493ꢀ(UL:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
83
Electronics
Computer Cable
Multi-Paired, Individually Foil/Braid Shielded, Lo-Cap®
ULꢀ2493,ꢀNECꢀTypeꢀCMꢀ(UL)ꢀc(UL)ꢀCMH
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀfoamedꢀ
Lo-Cap® polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
NOM.
NOMINAL
DCR**
NOMINAL
CAP.*
Shield:
VEL.
INSULATION JACKET
THICKNESS THICKNESS
NOMINAL
O.D.
NO.
OF NOM.
PROP., IMP.,
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairs
Ω/kft
pF/ft
CATALOG OF AWG COND.
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀinꢀ
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
C
D
E
%
Ω
A
B
ꢀ
ꢀ
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire,ꢀeachꢀ
pair
•ꢀꢀ70%ꢀtinnedꢀcopperꢀbraid,ꢀeachꢀpair
2
3
4
24 7/32 0.022 0.56 0.048 1.22 0.392 9.96 26.0 18.0 4.3 78 100 14.8 26.7
24 7/32 0.022 0.56 0.048 1.22 0.410 10.41 26.0 18.0 4.4 78 100 14.8 26.7
24 7/32 0.022 0.56 0.048 1.22 0.445 11.30 26.0 18.0 3.2 78 100 14.8 26.7
C0924A
C0925A
C0926A
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+75˚C
ꢀ
ꢀ
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
**C – Conductor resistance
**D – Individual shield resistance
**E – Overall shield resistance
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀHigh-speedꢀcomputers
•ꢀꢀIndustrialꢀequipment
•ꢀꢀControlꢀcircuits
•ꢀꢀDesignedꢀforꢀlowꢀcapacitanceꢀ
applications
Color Code Chart
NO. OF
PAIRS
COLOR
ꢀ
•ꢀꢀSuitableꢀforꢀRS-422ꢀCAD/CAMꢀ
BlackꢀpairedꢀwithꢀWhite
Black paired with Green
Black paired with Blue
applications
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
2
3
4
ꢀ
Features:
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀforꢀexcellentꢀ
ꢀ
signal isolation
ꢀ
ꢀ
•ꢀꢀExcellentꢀhigh-frequencyꢀproperties
•ꢀꢀMechanicalꢀdurability
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCM/CMHꢀ
(UL:ꢀ75˚C,ꢀ300V)
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀStyleꢀ2493ꢀ(UL:ꢀ60˚C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
VerticalꢀTrayꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
84
Electronics
Coaxial Cable
5
Index
Page
Coaxial Solutions Guide
86-87
RG 6/U Type
88-93
94-95
96-99
100
RG 8/U Type
RG 11/U Type
RG 58/U Type
RG 59/U Type
RG 62/U Type
RG 174/U Type
RG 213/U Type
Twinaxial Cables
To meet the needs of today’s
General Cable recommends,
sophisticated, high-speed, wide in order to avoid installing an
bandwidth electronics over long unacceptable coaxial cable for
101-108
109
distances, with minimum signal
loss or degradation, General
the CATV application in your
area, the local CATV company
Cable Carol® Brand offers a wide should be consulted.
range of coaxial and twinaxial
110
General Cable’s Carol® Brand
designs in both unbalanced
arrays and precision-balanced
pairs. This offers the system
designer a wide choice of cost-
effective products that reflect
the most recent changes in the
standards set by UL, CSA and/
or the FCC.
111
product mix encompasses
standard RG/U-type coaxial
constructions in the more
popular 50, 75 and 93 ohm
designs and miniature coaxial
products for smaller high-speed
applications.
112
The twinaxial products meet or
exceed the stringent demands
of today’s precision- balanced
pair systems. The minimization
of capacitance unbalance is a
necessary requirement for long
distance data transmission.
Included in this section are
recommended Carol® Brand
coaxial products for the
CATV market. However, these
constructions may differ in
certain parts of the country.
Unlike other products in the
electronic market, coaxial cable
does not have one accepted
standard construction.
85
Coaxial Cable
Solutions Guide
General Cable offers a complete line of Carol® Brand Coaxial Cables for
today’s sophisticated high-speed, wide-bandwidth electronics products
that run over long distances with minimal signal loss or degradation.
General Cable has the right coaxial cable to serve every application,
including:
• CATV/MATV/DBS
• HDTV/SDI
• CCTV
The General Cable Coaxial Cable Solutions Guide is a quick-reference
tool to make it easier to specify and sell the right cable for the required
application–residential, commercial, entertainment and security.
Whatever the application calls for, we have a coaxial cable that delivers
the performance your customers need.
Broadband signal, 5MHz–3GHz, VHF/UHF, is traditionally transmitted as an analog signal received directly off air (MATV) or delivered as a community
access television (CATV) service and uses a 75 Ohm system.
CATV/MATV/DBS
Recommended Coaxial Cable Construction: Copper clad steel (CCS) conductor with a foam polyethylene or Teflon* core, an aluminum/Mylar*
foil, a minimum of 60% braid, which is typically aluminum (AL) for this application, and a PVC jacket.
For home use, a CM rated coax should be used. A commercial application may require a National Electrical Code (NEC 800 or 725) Riser (CMR) or
Plenum (CMP) rated cable. Economical cable solutions use low smoke PVC (75˚C) jackets. Teflon* (FEP) and other fluoropolymer materials (150˚C)
may be used to provide a more durable and higher-temperature cable alternative.
It is a common misconception that RG 6 coax is “better” than RG 59. While RG 6 has become the industry standard and is an excellent value, it is
a larger cable than RG 59. RG 6 allows the same signal level to be delivered a greater distance. This is expressed as a decibel value at particular
frequencies. For example, at 100 MHz, General Cable’s Carol® Brand part number C5775 RG 6 coax cable has an attenuation value of 2.05 db/100'.
A similar construction Carol® Brand part number C5782 RG 59 coax cable exhibits an attenuation value (loss) at 100 MHz frequency of 2.70db/100'.
This may or may not be significant, depending on the input signal level and distance of the cable run.
For a longer cable run, or if the coax cable is planned for use as the backbone in a system, Carol® Brand part number C5039 RG 11 coax cable should
be used, because its attenuation at 100 MHz frequency is 1.30 db/100'.
CATV/MATV/DBS RG 59, RG 6 and RG 11 Ratings
Coax Solution
Carol
Belden
Genesis
West Penn
Commscope
RG 6 CCS/Foil/60% AL Braid CATV/CM
C5775
9116/1829A
5303
841
5726
RG 6 CCS/Foil/60% AL Braid CATVR/CMR
C5886
C5785
C5889
C3524
C3525
C5039
C3528
9116R
1189A
1884A
9116P
—
5307
—
—
Q841
—
—
5740
—
RG 6 CCS/Quad/Foil/60%/40% AL Braid CATV/CM
RG 6 CCS/Quad/Foil/60%/40% AL Braid CATVR/CMR
RG 6 CCS/Foil/60% AL Braid CMP - Plenum
—
25841
25Q841
—
2275K
—
RG 6 CCS/Quad/Foil/60%/40% AL Braid CMP - Plenum
RG 11 CCS/Foil/60% AL Braid CATV/CM
1189AP
1525A
1523AP
—
—
5913
RG 11 CCS/Foil/60% AL Braid CL2P/CMP - Plenum
—
—
2285K
*Note: DuPont™ trademark
86
A DTV signal is a television signal provided in a digital form. Data bits, like in a computer, provide a dramatically better picture and better sound
quality called High Definition TV (HDTV). HDTV is the highest quality of DTV and is only one of the available formats. In addition to enhanced picture
quality, the DTV signal allows several program streams (multicasting) on one channel, providing more program potential, as well as interactive
services.
HDTV/SDI
Serial Digital Interface (SDI) is the standard for digital video transmission over coaxial cable. The SMPTE 295M standard provides maximum distances
(300 meters; 140 meters for High Definition), typically at 270 Mbps with 540 Mbps possible over a coaxial cable.
Recommended Coax Cable Construction: Cable providing signal to and within the home/building will continue to be CCS construction (C5775,
C5785). Cables with SBC conductors (395011, 495025) are recommended for the interconnect between the decoder box and other electronic devices
(TV, DVD, DVR, CD, Bluray).
HDTV/SDI—Interconnect Cables RG 59, RG 6 and RG 11 Ratings
Coax Solution
Carol
Belden
Genesis
West Penn
Commscope
RG 59 SBC/Foil/95% TC Braid CMR
395025
1505A
5361
819
5553
RG 59 SBC/Foil/95% TC Braid CMP - Plenum
RG 6 SBC/Foil/95% TC Braid CMR
495023
395011
495025
395029
495027
1506A
1694A
1695A
7731A
7732A
—
—
—
—
—
—
—
—
—
—
—
5765
—
RG 6 SBC/Foil/95% TC Braid CMP - Plenum
RG 11 SBC/Foil/95% TC Braid CMR
—
RG 11 SBC/Foil/95% TC Braid CMP - Plenum
2286K
CCTV
Closed Circuit TV (CCTV) signals are typically lower-frequency analog signals. Attenuation increases as frequency increases, therefore lower
baseband signals are able to travel longer distances on an RG 59 type coaxial cable than a higher-frequency television signal. This is why RG 59 is
the most common coax for CCTV. It is becoming more common for Unshielded Twisted Pair (UTP) products, like Category 5e and 6 cables, to be used
for Closed Circuit over Twisted Pair (CCTP) or Web-enabled cameras implemented over a Power over Ethernet network architecture; however, these
solutions require the use of specialized equipment.
Recommended Coax Cable Construction: Solid bare copper (SBC) conductor and a bare copper (BC) braid shield with coverage of 90-95% to
minimize signal loss of both the horizontal and vertical sync signals. Stranded conductors are recommended for pan, zoom, tilt (PZT) cameras.
CCTV RG 59 and RG 11 Ratings
Coax Solution
Carol
Belden
Genesis
West Penn
Commscope
RG 59 SBC/95% BC Braid CM
C1142
543945
5001
—
—
RG 59 Stranded (7/30) BC/95% BC Braid CM
C1103
C8025
9259
9265
—
—
—
—
—
—
RG 59 Stranded (7/30) BC/95% BC Braid + 22 AWG (7/30)
Shielded Pair CM
RG 59 SBC/95% BC Braid + 18 AWG (7/26)
Unshielded Pair CM
C8028
C8030
549945
649948
—
—
—
—
—
—
RG 59 SBC/95% BC Braid + 18 AWG (7/26)
Unshielded Pair CMP - Plenum
RG 59 SBC/95% BC Braid CMP - Plenum
RG 11 SBC/95% BC Braid CM
495028
395058
495015
495035
643948
513945
613948
—
5351
—
25815
811
—
2037V
5905
RG 11 SBC/95% BC Braid CMP - Plenum
RG 6 BC/95% BC Braid CMP - Plenum
—
2286K
2277V
—
—
*Abbreviation Key
AL - aluminum
SBC - solid bare copper
CCS- copper clad steel
BC - bare copper
TC - tinned copper
87
Electronics
Coaxial Cable
RG 6/U Type
Product Construction:
Conductors:
Jacket:
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
ꢀ
•ꢀꢀPremiumꢀPVCꢀcompound
•ꢀꢀMATV
•ꢀꢀCATV
•ꢀꢀCCTV†
•ꢀꢀHDTV
ꢀ
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
Packaging:
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀfor
packaging and color options
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
•ꢀꢀDigitalꢀvideo
•ꢀꢀDropꢀcable
•ꢀꢀFMꢀbroadcast
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
ꢀ
Shield:
ꢀ
ꢀ
•ꢀꢀBareꢀcopperꢀorꢀaluminumꢀbraid
•ꢀFꢀ lexfoil® shield
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
18 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
30 Ga. CCS
Spiral Served
Shield
16.20 53.15
82
75
1
10
0.26
0.81
1.46
2.05
2.83
4.53
6.59
C5760
Foam PE
Black PVC
RG 6/U Type
50
100
200
500
1000
0.180
4.57
4.57
0.240
6.10
6.98
28.9 Ω/Mft.
30.0 Ω/Mft.
18 Ga.
Solid Bare
Copper
100% Flexfoil®
+95%
Bare Copper
Braid
16.20 53.15
83
83
75
75
1
10
50
100
200
500
1000
0.26
0.81
1.46
2.05
2.83
4.53
6.59
C5761†
Foam PE
Black PVC
RG 6/U Type
UL CL2, CATV, CM
c(UL) CM
0.180
0.275
6.5 Ω/Mft.
2.6 Ω/Mft.
18 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
+60%
Aluminum Braid
9.0 Ω/Mft.
16.20 53.15
1
10
50
100
200
500
1000
1450
1800
0.26
0.81
1.46
2.05
2.83
4.53
6.59
8.10
8.80
C5775
Foam PE
Black PVC
RG 6/U Type
UL CL2, CATV, CM
c(UL) CM
0.180
4.57
0.275
6.98
28.9 Ω/Mft.
2200 10.10
3000 11.79
18 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
+60%
Aluminum Braid
9.0 Ω/Mft.
16.20 53.15
83
75
1
10
0.26
0.81
1.46
2.05
2.83
4.53
6.59
8.10
8.80
C5886
Foam PE
0.180 4.57
Black PVC
0.275 6.98
RG 6/U Type
Riser
50
100
200
500
1000
1450
1800
UL CL2R, CATVR, CMR
c(UL) CMR
28.9 Ω/Mft.
2200 10.10
3000 11.79
18 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
+95%
Aluminum Braid
10.5 Ω/Mft.
16.20 53.15
83
75
1
10
0.26
0.81
1.46
2.05
2.83
4.53
6.59
8.10
8.80
C5776
Foam PE
0.180 4.57
Black PVC
0.275 6.98
RG 6/U Type
UL CL2, CATV, CM
c(UL) CM
50
100
200
500
1000
1450
1800
28.9 Ω/Mft.
2200 10.10
3000 11.79
88
Coaxial Cable
Electronics
RG 6/U Type
Product Construction:
Conductors:
Jacket:
Applications:
ꢀ
•ꢀꢀPremiumꢀPVCꢀcompoundꢀor
PEꢀcompound
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀCATV
•ꢀꢀMATV
•ꢀꢀHDTV
•ꢀꢀDigitalꢀvideo
•ꢀꢀDirectꢀburial
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
ꢀ
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
Packaging:
Insulation/Core:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
ꢀ
•ꢀꢀSolidꢀandꢀfoamꢀpolyethyleneꢀ(PE)ꢀ
packaging and color options
designs
Shield:
ꢀ
ꢀ
•ꢀꢀTinned,ꢀbareꢀcopperꢀorꢀaluminumꢀbraid
•ꢀFꢀ lexfoil® shield
INSULATION
MATERIAL
INCHES mm
NOMINAL
SHIELD
NOMINAL
CAPACITANCE
pF/ft pF/m
NOMINAL
ATTENUATION
MHz dB/100'
AWG
SIZE
NOM. DCR
VELOCITY OF NOMINAL
O.D.
CATALOG
NUMBER
COVERAGE
PROPAGATION, IMPEDANCE,
INCHES mm
NOM SHLD DCR
%
Ω
1
10
0.26
0.81
1.46
2.05
2.83
4.53
6.59
8.10
8.80
18 Ga.
Solid
Copper-Clad
Steel
(2) 100% Flexfoil®
1st Bonded
(1) 60%
(2) 40%
Aluminum Braids
3.7 Ω/Mft.
16.20 53.15
16.20 53.15
16.20 53.15
83
75
C5785
Foam PE
Black PVC
RG 6/U Type
Quad-Shield
UL CL2, CATV, CM
c(UL) CM
50
100
200
500
1000
1450
1800
0.180
4.57
0.292
7.42
28.9 Ω/Mft.
2200 10.10
3000 11.79
1
10
0.26
0.81
1.46
2.05
2.83
4.53
6.59
8.10
8.80
18 Ga.
Solid
Copper-Clad
Steel
(2) 100% Flexfoil®
1st Bonded
(1) 60%
(2) 40%
Aluminum Braids
3.7 Ω/Mft.
83
75
C5889
RG 6/U Type
Riser
Quad-Shield
UL CL2R, CATVR, CMR
c(UL) CM
Foam PE
0.180 4.57
Black PVC
0.292 7.42
50
100
200
500
1000
1450
1800
28.9 Ω/Mft.
2200 10.10
3000 11.79
1
10
0.26
0.81
1.46
2.05
2.83
4.53
6.59
8.10
8.80
18 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
+61%
Tinned Copper
Braid
83
75
C5777
Foam PE
0.180 4.57
Black PVC
RG 6/U Type
UL CL2, CATV, CM
c(UL) CM
50
100
200
500
1000
1450
1800
0.275
6.98
28.9 Ω/Mft.
6.5 Ω/Mft.
2200 10.10
3000 11.79
1
10
0.26
0.81
1.46
2.05
2.83
4.53
6.59
18 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
+60%
Aluminum Braid
9.0 Ω/Mft.
16.20 53.15
16.20 53.15
83
83
75
75
C5802
Foam PE
Black PVC
RG 6/U Type
Messengered,
Self-Supporting
50
100
200
500
1000
0.180
4.57
0.270
x
0.428
6.86
x
10.87
28.9 Ω/Mft.
1
10
0.26
0.81
1.46
2.05
2.83
4.53
6.59
18 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
C5804
RG 6/U Type
MoistureGuard™
Direct Burial, Flooded
Foam PE
Black PE
50
+60%
100
200
500
1000
0.180
4.57
0.275
6.98
Aluminum Braid
w/water block
9.0 Ω/Mft.
28.9 Ω/Mft.
FlexFill®
89
Electronics
Coaxial Cable
RG 6/U Type
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀTinnedꢀcopperꢀorꢀaluminumꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀLANꢀcable
•ꢀꢀHDTV
ꢀ
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
•ꢀꢀCCTV†
•ꢀꢀDigitalꢀvideo
•ꢀꢀDirectꢀbroadcastꢀsatellite
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Jacket:
•ꢀꢀPremiumꢀPVCꢀcompound
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
ꢀ
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
Packaging:
ꢀ
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
SHIELD
NOMINAL
CAPACITANCE
pF/ft pF/m
NOMINAL
ATTENUATION
MHz dB/100'
AWG
VELOCITY OF NOMINAL
O.D.
CATALOG
NUMBER
SIZE
COVERAGE
PROPAGATION, IMPEDANCE,
INCHES mm
NOM. DCR
NOM SHLD DCR
%
Ω
1
10
0.20
0.72
1.48
2.01
2.79
4.46
6.53
7.86
8.76
9.69
18 Ga.
Solid Bare
Copper
100% Flexfoil®
+95%
Tinned Copper
Braid
16.20 53.15
83
75
C5814†
Foam PE
Black PVC
RG 6/U Type
50
Digital Video/HDTV
UL CL2, CATV, CM
c(UL) CM
100
0.180
4.57
0.275
6.98
6.5 Ω/Mft.
200
500
2.7 Ω/Mft.
1000
1450
1800
2200
3000 11.31
1
10
0.26
0.81
1.46
2.05
2.83
4.53
6.59
8.10
8.80
18 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
+60%
Aluminum Braid
9.0 Ω/Mft.
16.20 53.15
83
75
C5822
Foam PE
Black PVC
RG 6/U Dual-Type
DBS
50
100
200
500
1000
1450
1800
0.180
4.57
0.267
x
6.86
x
15.11
UL CL2, CATV, CM
c(UL) CM
28.9 Ω/Mft.
0.595
2200 10.10
3000 11.79
90
Coaxial Cable
Electronics
RG 6/U Type
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀTinnedꢀcopperꢀorꢀaluminumꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀCATV
•ꢀꢀCCTV†
•ꢀꢀDBS
•ꢀꢀDropꢀcable
•ꢀꢀFMꢀbroadcast
•ꢀꢀHDTV
•ꢀꢀDigitalꢀvideo
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
orꢀcopper-cladꢀsteelꢀperꢀASTMꢀB-869
•ꢀꢀTwistedꢀpairꢀcolorꢀcode:ꢀblackꢀandꢀred
Jacket:
•ꢀꢀPremium-gradeꢀPVCꢀcompound
ꢀ
ꢀ
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
•ꢀꢀFoamꢀfluoropolymerꢀ(FEP)ꢀdesign
Packaging:
ꢀ
ꢀ
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
INSULATION
MATERIAL
INCHES mm
NOMINAL
SHIELD
NOMINAL
CAPACITANCE
pF/ft pF/m
NOMINAL
ATTENUATION
MHz dB/100'
AWG
SIZE
NOM. DCR
VELOCITY OF NOMINAL
O.D.
CATALOG
NUMBER
COVERAGE
PROPAGATION, IMPEDANCE,
INCHES mm
NOM SHLD DCR
%
Ω
1
10
0.26
0.81
1.46
2.05
2.83
4.53
6.59
8.10
8.80
18 Ga.
Solid Bare
Copper
100% Flexfoil®
Bonded
+61%
Tinned Copper
Braid
16.20 53.15
83
75
C5778
Foam PE
Black PVC
RG 6/U Type
UL CL2, CATV, CM
c(UL) CM
50
0.180
4.57
0.275
6.98
100
200
500
1000
1450
1800
6.5
Ω/Mft.
6.5 Ω/Mft.
2200 10.10
3000 11.79
Flexguard® PVC
Natural
1
10
0.30
0.66
1.50
2.10
3.10
5.00
7.30
18 Ga.
Solid Bare
Copper
100% Flexfoil®
+80%
Tinned Copper
Braid
16.40 52.50
16.00 52.50
16.00 52.50
83
83
83
75
75
75
C3523
Fluoropolymer
0.170 4.32
RG 6/U Type
Plenum
50
0.232
5.89
100
200
500
1000
6.5 Ω/Mft.
UL CL2P, CMP
c(UL) CMP
2.3 Ω/Mft.
Flexguard® PVC
Natural
1
10
50
100
200
500
1000
0.30
0.66
1.50
2.10
3.10
5.00
7.30
18 Ga.
Solid Bare
Copper
Flexfoil® Bonded
+95%
Tinned Copper
Braid
C3521
Fluoropolymer
0.170 4.32
RG 6/U Type
Plenum
0.232
5.89
6.5 Ω/Mft.
UL CL2P, CMP
c(UL) CMP
2.3 Ω/Mft.
Flexguard® PVC
Natural
1
10
50
100
200
500
1000
0.30
0.66
1.50
2.10
3.10
5.00
7.30
18 Ga.
Solid
Copper-Clad
Steel
Flexfoil® Bonded
+80%
Aluminum Braid
C3524
Fluoropolymer
0.170 4.32
RG 6/U Type
Plenum
0.232
5.89
9.0 Ω/Mft.
UL CL2P, CMP
c(UL) CMP
28.6 Ω/Mft.
2300 12.20
3000 14.28
Flexguard® PVC
Natural
1
10
0.30
0.66
1.50
2.10
3.10
5.00
7.30
18 Ga.
Solid
Copper-Clad
Steel
(2) 100%
Flexfoil®
(1) 60%
16.00 52.50
83
75
C3525
Fluoropolymer
RG 6/U Type
Quad Shield
Plenum
50
0.170
4.32
0.306
7.77
100
200
500
1000
2300 12.20
3000 14.28
(2) 40%
Aluminum Braids
5.3 Ω/Mft.
28.6
Ω/Mft.
UL CL2P, CMP
c(UL) CMP
1
10
0.20
0.72
1.48
2.01
2.70
4.46
6.53
18 Ga.
Solid Bare
Copper Coax
100% Flexfoil®
95% Bare
Copper Braid
16.20 53.15
83
83
75
75
C8029†
Foam PE
Black PVC
RG 6/U Type
+18 AWG
50
0.180
4.57
0.270
x
0.493
6.86
x
12.52
100
200
500
1000
1.9 Ω/Mft.
Unshielded Pair
UL CL2, CATV, CM
c(UL) CM
18 AWG
(7/26)
Unshielded
Pair
18 AWG
Solid Bare
Copper Coax
Premium PVC
0.010 0.25
Unshielded Pair
1
10
50
100
200
500
1000
0.30
0.66
1.50
2.10
3.10
5.00
7.30
95% Bare
Copper
Braid
16.30 53.48
C8031†
Fluoropolymer
Natural PVC
RG 6/U Type
+18 AWG
0.170
0.432
0.15
0.232
x
0.416
5.89
x
10.57
3.5 Ω/Mft.
Unshielded Pair
UL CMP
18 AWG
(7/26)
Unshielded
Pair
Halar
c(UL) CMP
Unshielded Pair
0.006
91
Electronics
Coaxial Cable
RG 6/U Type
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀTinnedꢀcopperꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀBroadlastꢀgradeꢀheadend
•ꢀꢀSerialꢀDigitalꢀInterfaceꢀ(SDI)
•ꢀꢀCATV
•ꢀꢀDBS
•ꢀꢀDropꢀcable
•ꢀꢀHDTV
•ꢀꢀCCTV†
•ꢀꢀDigitalꢀvideo
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
Jacket:
•ꢀꢀPremium-gradeꢀPVCꢀcompound
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
ꢀ
ꢀ
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
18 Ga.
Solid Bare
Copper
Dual Foil
+ 95% Tinned
Copper Braid
Shield
16.20 53.10
83
75
1
3.6
0.24
0.45
2.10
2.97
4.25
7.33
9.14
395011
Flame-Retardant
PVC
Foam PE
UL CMR
135
c(UL) CMG
270
0.180
4.57
0.275
6.91
5.89
6.5 Ω/Mft.
540
1500
2250
2.8 Ω/Mft.
3000 10.67
18 Ga.
Solid Bare
Copper
95% Bare
Copper Braid
16.20 52.50
16.10 53.00
16.10 53.00
83
83
83
75
75
75
1
10
0.21
0.65
1.46
2.04
2.98
5.18
7.05
8.64
495035†
UL CMP
c(UL) CMP
75°C
Fluoropolymer
0.170 4.32
Plenum PVC
50
2.0
Ω/Mft.
0.232
100
200
540
1000
1500
6.7 Ω/Mft.
2250 10.58
3000 12.21
18 Ga.
Solid Bare
Copper
95% Bare
Copper Braid
1
10
0.21
0.65
1.46
2.04
2.98
5.18
7.05
8.64
495036†
UL CMP
c(UL) CMP
105°C
Fluoropolymer
0.170 4.32
PVDF
50
2.0
Ω/Mft.
0.232
5.89
100
200
540
1000
1500
6.7 Ω/Mft.
2250 10.58
3000 12.21
18 Ga.
Solid Bare
Copper
Dual Foil
+ 95% Tinned
Copper Braid
Shield
1
3.6
0.24
0.45
2.40
2.75
4.00
6.36
495025
UL CMP
c(UL) CMP
Fluoropolymer
0.170 4.32
Plenum PVC
135
270
540
1500
0.232
5.89
6.5 Ω/Mft.
2.8 Ω/Mft.
2250 11.60
3000 13.70
92
Coaxial Cable
Electronics
RG 6/U Multi-Channel Digital/Precision, Riser Rated
75ꢀOhmꢀHigh-EndꢀCoaxialꢀCablesꢀforꢀExactingꢀVideo,ꢀAnalog,ꢀDigitalꢀ&ꢀMonitorꢀApplications
Product Construction:
Conductors:
Jacket:
Applications:
ꢀ
ꢀ
•ꢀꢀOuterꢀjacket:ꢀblackꢀmatteꢀfinishꢀ
thermoplasticꢀelastomerꢀ(TPE)
•ꢀꢀInnerꢀjacket:ꢀflame-retardantꢀPVC;ꢀ
see color codes below
ꢀ
•ꢀꢀAnalog/DigitalꢀVideoꢀBroadcast-Gradeꢀ
Monitor
•ꢀꢀHDTV
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
ꢀ
•ꢀSꢀ eeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
ꢀ
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
Shield:
packaging and color options
ꢀ
ꢀ
•ꢀDꢀ ualꢀFlexfoil® shield
•ꢀꢀTinnedꢀcopperꢀbraid
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
18 Ga.
3/Cond.
Solid Bare
Copper
Bi-Metal Foil
+ 95% Tinned
Copper Braid
Shield
16.20 53.20
83
75
1
3.6
0.24
0.45
1.60
2.97
4.25
7.33
395011-3
Inner:
Flame-Retardant
PVC
Outer:
TPE matte
Foam PE
UL CMR
71.5
270
c(UL) CMG
0.180
4.57
540
1500
6.5
Ω/Mft.
(2.8 Ohm)
0.685
17.40
18 Ga.
4/Cond.
Solid Bare
Copper
Bi-Metal Foil
+ 95% Tinned
Copper Braid
Shield
16.20 53.20
83
83
75
75
1
3.6
0.24
0.45
1.60
2.97
4.25
7.33
395011-4
UL CMR
Inner:
Flame-Retardant
PVC
Outer:
TPE matte
Foam PE
71.5
270
c(UL) CMG
0.180
4.57
540
1500
6.5
Ω/Mft.
(2.8 Ohm)
0.755
19.18
18 Ga.
5/Cond.
Solid Bare
Copper
Bi-Metal Foil
+ 95% Tinned
Copper Braid
Shield
16.20 53.20
1
3.6
0.24
0.45
1.60
2.97
4.25
7.33
395011-5
UL CMR
c(UL) CMG
Inner:
Flame-Retardant
PVC
Outer:
TPE matte
Foam PE
71.5
270
0.180
4.57
540
6.5
Ω/Mft.
(2.8 Ohm)
1500
0.860
21.85
Inner Jacket
Color Code Chart
Ordering
Suffix
COLOR
Red
1
2
3
4
5
Green
Blue
White
Yellow
Note:ꢀ395011-3ꢀwillꢀhaveꢀtheꢀfirstꢀthreeꢀcolors,ꢀ
ꢀ
ꢀ
395011-4ꢀwillꢀhaveꢀtheꢀfirstꢀfourꢀcolorsꢀ
andꢀ395011-5ꢀwillꢀhaveꢀallꢀfiveꢀcolors.
93
Electronics
Coaxial Cable
RG 8/U Type
Product Construction:
Conductors:
Shield:
Packaging:
ꢀ
ꢀ
•ꢀꢀTinnedꢀorꢀbareꢀcopperꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
Applications:
Jacket:
•ꢀꢀPremiumꢀPVCꢀcompound
Insulation/Core:
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀBroadcast
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
ꢀ
ꢀ
•ꢀꢀSolidꢀandꢀcellularꢀpolyethyleneꢀdesigns
INSULATION
MATERIAL
INCHES mm
NOMINAL
NOMINAL
NOMINAL
AWG
SIZE
NOM. DCR
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
O.D.
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
COVERAGE
INCHES mm
pF/ft pF/m
MHz dB/100'
NOM SHLD DCR
%
Ω
16 Ga.
(19/28)
Bare
Copper
4.2 Ω/Mft.
95% Bare
Copper Braid
3.3 Ω/Mft.
25.30 83.01
80
50
1
10
0.26
0.98
2.30
3.30
4.90
8.50
C1108A
Foam PE
Black PVC
RG 8/U Mini Type
UL CL2, CM
CSA CMG
50
100
200
500
0.155
3.94
7.24
0.242
6.15
1354
1000 14.30
13 Ga.
(7/21)
Bare
95% Bare
Copper Braid
1.2 Ω/Mft.
29.50 96.79
66
52
1
10
50
100
200
500
1000
0.16
0.56
1.30
1.90
2.80
4.70
7.40
C1154
Solid PE
Black PVC
RG 8/U Type
JAN-C-17A TYPE
1354
0.285
0.405
10.29
Copper
1.9
Ω/Mft.
11 Ga.
(19/24)
Bare
95% Bare
Copper Braid
1.1 Ω/Mft.
26.00 85.31
24.60 80.71
78
84
50
50
1
10
0.17
0.57
1.20
1.80
2.70
4.70
7.10
C1198
Foam PE
Black PVC
RG 8/U Type
1354
50
100
200
500
1000
0.285
7.24
0.405
10.29
Copper
1.9
Ω/Mft.
9½ Ga.
Solid Bare
Copper
100% Flexfoil®
Bonded
+88%
Tinned Copper
Braid
1
10
50
100
200
500
1000
0.13
0.40
0.90
1.30
1.80
3.00
4.50
C1180
RG 8/U Type
Semi-Solid PE
0.285 7.24
Black PVC
0.405
10.29
0.90
Ω/Mft.
1.8 Ω/Mft.
94
Coaxial Cable
Electronics
RG 8/U Type Thicknet/Trunk Cable
50ꢀOhmꢀIEEEꢀ802.3ꢀandꢀISO/IECꢀ8802.3ꢀ10ꢀBaseꢀ5ꢀLANꢀandꢀComputerꢀCables
Product Construction:
Conductors:
Jacket:
Applications:
ꢀ
ꢀ
•ꢀꢀPremiumꢀPVCꢀcompound
•ꢀꢀPremiumꢀfluoropolymerꢀcompoundꢀ
ꢀ
ꢀ
•ꢀLꢀ ANꢀ&ꢀdataꢀtransmissionꢀcomputerꢀcables
•ꢀꢀThicknet/trunkꢀcableꢀ–ꢀIEEEꢀ802.3ꢀ
andꢀISO/IECꢀ8802.3ꢀ10ꢀbaseꢀ5ꢀLANꢀ
computer cables
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
Packaging:
Insulation/Core:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
ꢀ
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
ꢀ
ꢀ
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
•ꢀꢀFoamꢀfluoropolymerꢀ(FEP)ꢀdesign
packaging and color options
pages 192-199
Shield:
•ꢀꢀTinnedꢀcopperꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
12 Ga.
Solid Bare
Copper
1
5
0.17
0.37
0.53
1.20
1.73
2.50
3.64
4.97
5.74
6.10
Quad Shield
Dual Flexfoil®
94% Tinned
Copper Braid
+ Dual Flexfoil®
94% Tinned
Yellow
Flame-Retardant
PVC
26.00 85.30
78
50
397001
Foam PE
RG 8/U Type
THICKNET
10
50
1.42 Ω/Mft.
DEC 17-000451-00
UL CM c(UL)
100
200
400
700
900
1000
0.245
6.22
0.405
10.29
Copper Braid
1.52 Ω/Mft.
1
5
0.16
0.35
0.51
1.19
1.75
2.61
3.97
5.65
6.67
7.14
12 Ga.
Solid Bare
Copper
Quad Shield
Dual Flexfoil®
94% Tinned
Copper Braid
+ Dual Flexfoil®
94% Tinned
Orange
PVDF
25.00 82.00
84
50
497001
Fluoropolymer
0.245 6.22
RG 8/U Type
THICKNET
10
50
0.375
9.53
1.42
Ω/Mft.
DEC 17-000324-00
UL CMP c(UL)
100
200
400
700
900
1000
Copper Braid
1.52 Ω/Mft.
95
Electronics
Coaxial Cable
RG 11/U Type
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀTinned,ꢀbareꢀcopperꢀorꢀaluminumꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmissionꢀ
•ꢀꢀBroadcastꢀdigitalꢀvideo
•ꢀꢀMATV
•ꢀꢀCATV†
•ꢀꢀDropꢀcable
•ꢀꢀHDTV
•ꢀꢀCCTV
ꢀ
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
Jacket:
•ꢀꢀPremiumꢀPVCꢀcompoundꢀor
PEꢀcompound
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
ꢀ
Insulation/Core:
ꢀ
•ꢀꢀSolidꢀandꢀfoamꢀpolyethyleneꢀ(PE)ꢀ
Packaging:
designs
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
18 Ga.
(7/26)
Tinned
Copper
95% Bare
Copper Braid
1.2 Ω/Mft.
1
10
0.20
0.70
1.30
2.00
2.90
4.70
7.10
C1160
20.50 67.26
66
75
Solid PE
Black PVC
RG 11/U Type
50
JAN-C-17A Type
0.285
6.55
7.11
0.400
10.16
10.03
100
200
500
1000
6.1 Ω/Mft.
14 Ga.
Solid
Bare
100% Flexfoil®
+95%
Bare Copper
Braid
1
10
0.13
0.40
0.90
1.30
1.90
3.00
4.40
5.30
5.90
6.53
7.62
C5011†
16.20 53.15
85
75
Foam PE
Black PVC
RG 11/U Type
UL CL2, CATV, CM
c(UL) CM
50
0.280
0.395
100
Copper
200
2.5
Ω/Mft.
1.2 Ω/Mft.
500
1000
1450
1800
2200
3000
14 Ga.
Solid
Copper-Clad
Steel
97% Bare
Copper Braid
1.2 Ω/Mft.
1
10
0.30
0.70
1.00
1.50
2.20
3.70
5.30
6.38
7.11
7.86
9.18
C5025
RG 11/U Type
16.20 53.15
83
75
Foam PE
0.285 7.24
Black PE
0.405 10.29
50
100
200
11.4 Ω/Mft.
500
1000
1450
1800
2200
3000
14 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
+61%
Tinned Copper
Braid
16.20 53.15
85
75
1
10
0.30
0.70
0.90
1.30
1.90
3.00
4.40
5.30
5.90
6.53
7.62
C5029
Foam PE
0.280 7.11
Black PVC
0.395 10.03
RG 11/U Type
UL CL2, CM
c(UL) CM
50
100
200
500
11.4 Ω/Mft.
1000
1450
1800
2200
3000
3.0 Ω/Mft.
14 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
+40%
Aluminum Braid
1
10
0.30
0.70
0.90
1.30
1.90
3.00
4.40
C5034
RG 11/U Type
1354
16.20 53.15
85
75
Foam PE
0.280 7.11
Black PVC
0.395 10.03
50
100
200
500
1000
11.4
Ω/Mft.
5.3 Ω/Mft.
96
Coaxial Cable
Electronics
RG 11/U Type
Product Construction:
Conductor:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀTinned,ꢀbareꢀcopperꢀorꢀaluminumꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmissionꢀ
•ꢀꢀBroadcastꢀdigitalꢀvideo
•ꢀꢀMATV
•ꢀꢀCATV
•ꢀꢀDropꢀcable
•ꢀꢀHDTV
•ꢀꢀDirectꢀburial
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
ꢀ
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
Jacket:
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-3
ꢀ
•ꢀꢀPremiumꢀPVCꢀcompound,ꢀFlexguard® or
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
•ꢀꢀFoamꢀfluoropolymerꢀ(FEP)ꢀdesign
PEꢀcompound
ꢀ
ꢀ
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
14 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
+60%
Aluminum Braid
1
10
0.30
0.70
0.90
1.30
1.90
3.00
4.40
5.30
5.90
6.53
7.62
C5039
16.20 53.15
85
75
Foam PE
Black PVC
RG 11/U Type
UL CL2, CATV, CM
CSA CMG
50
0.280
7.11
0.395
10.03
100
200
11.4
Ω/Mft.
4.6 Ω/Mft.
1354
500
1000
1450
1800
2200
3000
14 Ga.
Solid
Copper-Clad
Steel
(2) 100% Flexfoil®
1st Bonded
(1) 61%
(2) 40%
Aluminum Braids
3.4 Ω/Mft.
1
10
0.30
0.70
0.90
1.30
1.90
3.00
4.40
5.30
5.90
6.53
7.62
C5044
16.20 53.15
85
75
Foam PE
0.280 7.11
Black PVC
0.405 10.29
RG 11/U Type
Quad-Shield
UL CL2, CATV, CM
CSA CMG
50
100
200
11.4
Ω/Mft.
500
1354
1000
1450
1800
2200
3000
14 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
+60%
Aluminum Braids
4.6 Ω/Mft.
16.00 52.50
82
75
1
10
0.15
0.47
1.09
1.49
2.35
3.94
6.19
7.45
8.30
9.18
C3528
Fluoropolymer
0.280 7.11
PVDF Jacket
0.351 8.92
RG 11/U Type
Plenum
50
100
200
500
1000
1450
1800
2200
UL CL2P, CMP
c(UL) CMP
CATVP
11.4 Ω/Mft.
97
Electronics
Coaxial Cable
RG 11/U Type
Product Construction:
Conductor:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀBareꢀcopperꢀorꢀaluminumꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmissionꢀ
•ꢀꢀBroadcast/digitalꢀvideo
•ꢀꢀMATV
•ꢀꢀCATV
•ꢀꢀDropꢀcable
•ꢀꢀHDTV
•ꢀꢀDirectꢀburial
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
ꢀ
ꢀ
•ꢀꢀStrandedꢀorꢀsolidꢀcopperꢀperꢀASTMꢀB-3
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
Jacket:
ꢀ
•ꢀꢀPremiumꢀfluoropolymerꢀcompoundꢀorꢀ
premiumꢀpolythyleneꢀ(PE)ꢀcompound
Insulation/Core:
ꢀ
ꢀ
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
•ꢀꢀFoamꢀfluoropolymerꢀ(FEP)ꢀdesign
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
INSULATION
MATERIAL
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SIZE
NOM. DCR
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
COVERAGE
INCHES
mm
pF/ft pF/m
MHz dB/100'
NOM SHLD DCR
%
Ω
14 Ga.
Solid
Copper-Clad
Steel
(2) 100% Flexfoil®
(1) 60%
(2) 40%
Aluminum Braids
3.4 Ω/Mft.
16.00 52.50
82
75
1
10
0.15
0.47
1.09
1.49
2.35
3.94
6.19
7.45
8.30
9.18
C3529
Fluoropolymer
PVDF Jacket
RG 11/U Type
Quad-Shield
Plenum
50
100
200
0.280
7.11
0.372
9.45
500
11.4 Ω/Mft.
UL CL2P, CMP
c(UL) CMP
CATVP
1000
1450
1800
2200
14 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded
16.20 53.15
85
75
1
10
0.30
0.70
0.90
1.30
1.90
3.00
4.40
C5043
Foam PE
0.280 7.11
Black PE
RG 11/U Type
MoistureGuard™
Direct Burial, Flooded
50
+60%
100
200
500
1000
0.395
10.03
Aluminum Braid
w/water block
5.3 Ω/Mft.
11.4 Ω/Mft.
FlexFill®
98
Coaxial Cable
Electronics
RG 11/U Type Serial Digital Interface (SDI) Precision Cable
Extended-Distance,ꢀ75ꢀOhmꢀHigh-EndꢀCoaxialꢀCablesꢀforꢀExactingꢀVideo,ꢀAnalogꢀ&ꢀDigitalꢀApplications
Product Construction:
Conductor:
Jacket:
Applications:
ꢀ
•ꢀꢀPremiumꢀPVCꢀcompoundꢀorꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmissionꢀ
•ꢀꢀBroadcast-gradeꢀSerialꢀDigitalꢀ
Interfaceꢀ(SDI)
fluoropolymer
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
Packaging:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀAnalog/digitalꢀvideo
•ꢀꢀMATV
•ꢀꢀCATV
•ꢀꢀCCTV†
•ꢀꢀDropꢀcable
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
•ꢀꢀFoamꢀfluoropolymerꢀ(FEP)ꢀdesign
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
ꢀ
ꢀ
packaging and color options
Shield:
•ꢀꢀBareꢀcopperꢀorꢀtinnedꢀcopper
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
•ꢀꢀHDTV
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
14 Ga.
Solid Bare
Copper
95% Bare
Copper Braid
1.2 Ω/Mft.
1
10
0.17
0.35
0.90
1.30
1.90
2.90
3.37
4.59
6.88
7.94
395058†
16.20 52.50
84
75
Flame-Retardant
PVC
Foam PE
RG 11/U Type
UL CM
50
100
200
400
540
1000
2250
3000
0.285
7.24
0.405
10.29
2.6 Ω/Mft.
c(UL) CMG
14 Ga.
Solid Bare
Copper
Dual Flexfoil®
+ 95% Tinned
Copper Braid
1
3.6
0.15
0.28
1.62
2.31
3.29
5.60
6.94
8.10
395029
16.20 53.10
83
84
75
75
Flame-Retardant
PVC
Foam PE
RG 11/U Type
UL CMR
135
270
0.280
7.11
0.405
10.29
2.6
Ω/Mft.
1.5 Ω/Mft.
c(UL) CMG
540
1500
2250
3000
14 Ga.
Solid Bare
Copper
95% Bare
Copper Braid
1.2 Ω/Mft.
1
10
50
100
200
400
540
1000
2250
3000
0.17
0.35
0.90
1.30
1.90
2.90
3.37
4.59
6.88
7.94
495015†
16.20 52.50
Fluoropolymer
0.280 7.11
PVDF
0.351
RG 11/U Type
UL CMP
8.92
2.6 Ω/Mft.
c(UL) CMP
14 Ga.
Solid Bare
Copper
Dual Flexfoil®
+ 60% AL Braid
3.0 Ω/Mft.
1
10
0.15
0.40
1.00
1.50
2.20
3.30
3.83
5.22
7.83
9.04
495016†
16.20 53.10
84
75
Fluoropolymer
0.280 7.11
PVDF
0.351
RG 11/U Type
UL CMP
50
100
200
400
540
1000
2250
3000
8.92
2.6 Ω/Mft.
c(UL) CMP
14 Ga.
Solid Bare
Copper
Dual Flexfoil®
+ 95% Tinned
Copper Braid
Shield
1
3.6
0.12
0.24
1.63
2.49
3.89
7.88
495027
16.20 53.10
84
75
Fluoropolymer
0.280 7.11
PVDF
0.348
RG 11/U Type
UL CMP
135
270
540
1500
8.84
2.6 Ω/Mft.
c(UL) CMP
1.5 Ω/Mft.
2250 10.61
3000 12.35
99
Electronics
Coaxial Cable
RG 58/U Type
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀTinnedꢀcopperꢀbraid
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀBroadcast
•ꢀ ANꢀ&ꢀdataꢀtransmission
Jacket:
•ꢀꢀPremiumꢀPVCꢀcompound
ꢀ
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
L
•ꢀꢀTinnedꢀcopperꢀperꢀASTMꢀB-33
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Insulation/Core:
Packaging:
ꢀ
ꢀ
•ꢀꢀSolidꢀandꢀfoamꢀpolyethyleneꢀ(PE)ꢀ
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
designs
packaging and color options
•ꢀꢀSolidꢀandꢀfoamꢀfluoropolymerꢀ(FEP)ꢀ
design
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SIZE
NOM. DCR
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
COVERAGE
pF/ft
pF/m
MHz dB/100'
NOM SHLD DCR
%
Ω
20 Ga.
Solid Bare
Copper
70% Tinned
Copper Braid
6.0 Ω/Mft.
28.50 93.51
30.80 101.05
30.00 98.43
66
53
1
10
0.40
1.20
2.90
4.20
6.00
C1117
Solid PE
Black PVC
RG 58/U Type
50
0.116
2.95
0.195
4.95
100
200
500 10.17
1000 16.50
10.1 Ω/Mft.
20 Ga.
(19/.0071)
Tinned
Copper
10.8 Ω/Mft.
95% Tinned
Copper Braid
4.3 Ω/Mft.
66
66
50
50
1
10
50
0.42
1.50
3.70
5.40
8.10
Non-Contaminating
Black PVC
C1155
RG 58 C/U Type
MIL-C-17G Type
Solid PE
0.116
2.95
100
200
500 13.86
1000 22.80
0.195
4.95
20 Ga.
Solid Bare
Copper
95% Tinned
Copper Braid
4.3 Ω/Mft.
1
10
50
0.40
1.20
2.90
4.20
6.00
C1166
Solid PE
Black PVC
RG 58/U Type
JAN-C-17A Type
1354
0.116
2.95
0.195
0.195
4.95
100
200
500 10.17
1000 16.50
10.1 Ω/Mft.
20 Ga.
(19/.0071)
Tinned
Copper
10.8 Ω/Mft.
95% Tinned
Copper Braid
4.3 Ω/Mft.
31.80 104.34
66
78
50
50
1
10
50
0.42
1.50
3.70
5.40
8.10
C1178
Solid PE
Black PVC
RG 58A/U Type
JAN-C-17A Type
1354
0.116
2.95
4.95
100
200
500 13.96
1000 22.80
20 Ga.
(19/32)
Tinned
Copper
9.5 Ω/Mft.
95% Tinned
Copper Braid
4.3 Ω/Mft.
26.00 85.31
1
10
50
0.45
1.42
3.20
4.50
6.40
C1188
Foam PE
Black PVC
RG 58 A/U Type
UL CL2, CM
CSA CMG
1354
100
200
500 10.06
1000 14.50
0.114
2.90
0.195
4.95
Flexguard® PVC
Natural
19 Ga.
Solid Bare
Copper
95% Tinned
Copper Braid
2.9 Ω/Mft.
25.00 82.00
82
50
1
10
0.40
1.30
2.80
3.90
6.00
9.50
C3519
Fluoropolymer
0.102 2.59
RG 58/U Type
Plenum
50
100
200
500
0.161
4.09
8.1 Ω/Mft.
UL CL2P, CMP
c(UL) CMP
1000 13.50
100
Coaxial Cable
Electronics
RG 59/U Type
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
ꢀ
ꢀ
•ꢀꢀBareꢀcopperꢀbraid
•ꢀꢀCATV
•ꢀꢀMATV
•ꢀꢀCCTV†
•ꢀꢀLocalꢀAreaꢀNetwork
•ꢀꢀDigitalꢀvideo
•ꢀꢀMonitor/VDTꢀdisplay
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Jacket:
ꢀ
ꢀ
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
•ꢀꢀTwistedꢀpairꢀcolorꢀcode:ꢀblackꢀandꢀred
•ꢀꢀPremiumꢀPVCꢀcompoundꢀorꢀ
PEꢀcompound
Packaging:
Insulation/Core:
•ꢀꢀSolidꢀandꢀcellularꢀpolyethyleneꢀ(PE)ꢀ
designsꢀorꢀfoamꢀfluoropolymerꢀ(FEP)ꢀ
design
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
ꢀ
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
1
10
0.26
0.82
20 Ga. Solid
Copper-Clad
Steel
95% Bare
Copper Braid
3.5 Ω/Mft.
17.30 56.76
82
75
C1102
RG 59/U Type
Foam PE
Black PE
50
1.80
100
2.60
45.9 Ω/Mft.
200
3.70
0.146
3.71
0.242
6.15
500
6.00
1000
1450
1800
2200
3000
8.80
10.60
11.81
13.05
15.24
1
0.41
22 Ga. Solid
Copper-Clad
Steel
95% Bare
Copper Braid
2.6 Ω/Mft.
20.50 67.26
16.30 53.48
17.00 55.78
16.20 53.15
21.00 68.90
16.30 53.48
66
78
78
78
66
83
73
80
76
71
73
75
C1104
10
0.99
Solid PE
Black PVC
RG 59/U Type
1354
50
2.38
100
3.49
73.4 Ω/Mft.
200
5.09
0.242
0.242
6.15
0.146
3.71
500
8.43
1000
1450
1800
2200
3000
13.03
15.69
17.48
19.33
22.57
1
0.42
22 Ga. Solid
Copper-Clad
Steel
95% Bare
Copper Braid
2.6 Ω/Mft.
C1135
10
0.92
Foam PE
Black PVC
RG 59/U Type
UL CL2, CATV, CM
CSA CMG
1354
50
2.10
100
2.90
73.4 Ω/Mft.
200
4.10
6.15
0.146
3.71
500
6.60
1000
1450
1800
2200
3000
9.30
11.20
12.48
13.79
16.11
1
0.26
22 Ga.
(7/30)
Bare Copper
14.8 Ω/Mft.
95% Bare
Copper Braid
2.6 Ω/Mft.
C1103
†
10
0.91
Black PVC
Foam PE
RG 59/U Type
UL CL2, CATV, CM
CSA CMG
50
2.09
100
3.00
200
4.33
0.242
6.15
0.146
3.71
500
7.03
1354
1000
1450
1800
2200
3000
10.64
12.81
14.28
15.78
18.43
1
0.25
20 Ga. Solid
Bare Copper
10.1 Ω/Mft.
95% Bare
Copper Braid
2.6 Ω/Mft.
C1142
†
10
0.78
Foam PE
Black PVC
RG 59/U Type
UL CL2, CATV, CM CSA
CMG
50
1.97
100
2.79
200
3.97
0.234
5.94
0.146
3.71
500
6.35
1354
1000
1450
1800
2200
3000
9.15
11.02
12.28
13.57
15.85
1
0.44
23 Ga. Solid
Copper-Clad
Steel
95% Bare
Copper Braid
2.6 Ω/Mft.
C1106
Non-Contaminating
Black PVC
10
1.02
Solid PE
RG 59B/U Type
MIL-C-17D Type
1354
50
2.44
100
3.55
68.5 Ω/Mft.
200
5.18
0.242
6.15
0.146
3.71
500
8.59
1000
1450
1800
2200
3000
13.56
16.33
18.19
20.11
23.49
1
0.78
1.90
1.98
2.80
4.10
6.82
9.64
20 AWG Solid
BC Coax
18 AWG (7/26)
Unshielded
Pair
95% Bare
Copper Braid
C8030
†
Fluoropolymer
Natural PVC
10
RG 59/U Type
50
0.200
X
0.383
5.08
X
9.73
+18 AWG Unshielded Pair
UL CMP c(UL) CMP
100
200
500
1000
0.135
3.43
Unshielded
Pair
PVC
0.006
0.15
101
Electronics
Coaxial Cable
RG 59/U Type
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀTinned,ꢀbareꢀcopperꢀorꢀaluminumꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀMATV
•ꢀꢀCATV
•ꢀꢀCCTV†
•ꢀꢀLocalꢀAreaꢀNetwork
•ꢀꢀMonitor/VDTꢀdisplay
•ꢀꢀAnalogꢀvideo
•ꢀꢀDigitalꢀvideo
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
ꢀ
ꢀ
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
•ꢀꢀTwistedꢀpairꢀcolorꢀcode:ꢀblackꢀandꢀred
Jacket:
•ꢀꢀPremiumꢀPVCꢀcompound
ꢀ
Insulation/Core:
Packaging:
ꢀ
•ꢀꢀSolidꢀandꢀfoamꢀpolyethyleneꢀ(PE)ꢀ
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
designs
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
22 Ga. Solid
Copper-Clad
Steel
70% Bare
Copper Braid
4.5 Ω/Mft.
22.00 72.18
66
73
0.41
0.99
2.38
3.49
5.09
8.43
C1110
RG 59/U Type
1354
1
10
Solid PE
Black PVC
50
100
200
500
0.146
3.71
0.242
6.15
73.4 Ω/Mft.
1000 13.03
1450 15.69
1800 17.48
2200 19.33
3000 22.57
22 Ga. Solid
Copper-Clad
Steel
70% Bare
Copper Braid
4.5 Ω/Mft.
16.30 53.48
78
80
0.42
0.92
2.10
2.90
4.10
6.60
9.30
C1112
RG 59/U Type
1
10
Foam PE
0.146 3.71
Black PVC
50
100
200
500
1000
1450 11.20
1800 12.48
2200 13.79
3000 16.11
73.4 Ω/Mft.
0.242
6.15
22 AWG
(7/30) Bare
Copper Coax
95% Bare
Copper Braid
17.00 57.78
78
76
1
10
0.26
0.91
2.90
3.00
4.33
7.03
C8025
†
Foam PE
0.144 3.66
Premium PVC
0.013 0.33
Black PVC
RG 59/U Type
50
+22 AWG Shielded Pair
UL CL2, CATV, CM
c(UL) CM
100
200
500
0.242
X
6.147
X
11.30
22 AWG (7/30)
Shielded Pair
0.445
100% Flexfoil®
AI/PP Shielded
1000 10.64
102
Coaxial Cable
Electronics
RG 59/U Type
Product Construction:
Conductors:
Jacket:
Applications:
ꢀ
•ꢀꢀPremiumꢀPVCꢀcompound
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀCATV
•ꢀꢀMATV
•ꢀꢀDropꢀcable
•ꢀꢀLocalꢀAreaꢀNetwork
•ꢀꢀMonitor/VDTꢀdisplay
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Packaging:
ꢀ
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
packaging and color options
ꢀ
Shield:
•ꢀꢀAluminumꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
22 Ga. Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded + 40%
Aluminum
Braid
11.0 Ω/Mft.
16.00 52.50
78
80
1
10
0.50
1.00
2.30
3.30
4.10
6.50
9.40
C5770
Foam PE
Black PVC
RG 59/U Type
UL CL2, CATV, CM
CSA CMG
50
100
200
500
1000
1450 11.32
1800 12.61
2200 13.94
3000 16.28
73.4
Ω/Mft.
0.144
3.66
0.231
5.87
1354
20 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded + 40%
Aluminum
Braid
11.0 Ω/Mft.
16.20 53.15
16.20 53.15
16.20 53.15
85
85
85
75
75
75
1
10
0.60
1.20
1.95
2.70
3.70
5.70
8.12
9.78
C5780
Foam PE
0.144 3.66
Black PVC
0.234 5.94
RG 59/U Type
MATV
50
100
200
500
1000
1450
1800 10.89
2200 12.04
3000 14.06
UL CL2, CATV, CM
CSA CMG
1354
45.9
Ω/Mft.
20 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
Bonded + 95%
Aluminum
1
10
50
100
200
500
1000
1450
0.60
1.20
1.95
2.70
3.70
5.70
8.12
9.78
C5830
Foam PE
0.144 3.66
Black PVC
0.242 6.15
RG 59/U Type
Tri-Shield
Braid +
UL CL2, CATV, CM
c(UL) CM
45.9 Ω/Mft.
100% Flexfoil®
3.0 Ω/Mft.
1800 10.89
2200 12.04
3000 14.06
20 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
1st Bonded
(1) 67%
(2) 46%
Aluminum
Braids
1
10
50
100
200
500
1000
1450
0.60
1.20
1.95
2.70
3.70
5.70
8.12
9.78
C5784
Foam PE
0.144 3.66
Black PVC
0.270 6.86
RG 59/U Type
Quad-Shield
UL CL2, CATV, CM
CSA CMG
45.9
Ω/Mft.
1354
4.1 Ω/Mft.
1800 10.89
2200 12.04
3000 14.06
103
Electronics
Coaxial Cable
RG 59/U Type
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀBareꢀcopperꢀorꢀaluminumꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀMATV
•ꢀꢀCATV
•ꢀꢀCCTV†
ꢀ
ꢀ
ꢀ
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
•ꢀꢀCopperꢀperꢀASTMꢀB-3
Jacket:
•ꢀꢀPremiumꢀPVCꢀcompound
•ꢀꢀTwistedꢀpairꢀcolorꢀcode:ꢀblackꢀandꢀred
ꢀ
•ꢀꢀLocalꢀAreaꢀNetwork
•ꢀꢀMonitor/VDTꢀdisplay
•ꢀꢀDirectꢀburial
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
Packaging:
ꢀ
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SIZE
NOM. DCR
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM SHLD DCR
%
Ω
20 Ga.
Solid
Copper-Clad
Steel
100% Flexfoil®
+65%
Aluminum Braid
10.7 Ω/Mft.
16.00 52.50
84
75
1
10
0.34
1.07
1.77
2.50
3.53
5.98
8.45
Flexguard®
Natural
C3526
Fluoropolymer
RG 59/U Type
Plenum
50
100
200
500
1000
UL CL2P, CMP
c(UL) CMP
0.135
3.429
0.202
5.13
45.9 Ω/Mft.
2300 14.10
20 Ga.
Solid
Copper-Clad
Steel
(2) 100% Flexfoil®
(1) 60%
(2) 40%
Aluminum Braid
6.3 Ω/Mft.
16.00 52.50
16.50 54.14
17.00 55.78
84
83
78
75
75
76
1
10
0.34
1.07
1.77
2.50
3.53
5.98
8.45
Flexguard®
Natural
C3527
Fluoropolymer
0.135 3.429
RG 59/U Type
Quad-Shield Plenum
UL CL2P, CMP
c(UL) CMP
50
100
200
500
1000
0.235 5.97
45.9 Ω/Mft.
2300 14.10
Flexguard® PVC
Natural
20 Ga.
Solid
Copper-Clad
Steel
95% Bare
Copper Braid
1.9 Ω/Mft.
1
10
50
100
200
500
1000
0.78
1.90
1.98
2.80
4.10
6.82
9.64
C3500
Fluoropolymer
RG 59/U Type
Plenum
UL CL2P, CMP
c(UL) CMP
0.145
3.68
0.201
5.11
45.9 Ω/Mft.
22 AWG
(7/30) Bare
Copper Coax
18 AWG
(16/30)
Shielded Pair
95% Bare
Copper Braid
1
10
50
100
200
500
0.26
0.91
2.09
3.00
4.33
7.03
C8027†
Foam PE
Black PVC
RG 59/U Type
+18 AWG
0.242
X
0.480
6.15
X
12.19
Shielded Pair
UL CL2, CATV, CM
c(UL) CM
0.144
3.66
125% Flexfoil®
AI/PP Shielded
Premium PVC
1000 10.64
0.016
0.41
20 AWG
Solid Bare
Copper Coax
18 AWG
(7/26)
Unshielded
Pair
95% Bare
Copper Braid
16.20 53.15
78
71
1
10
0.25
0.78
1.97
2.70
3.97
6.35
9.15
C8028†
Foam PE
Black PVC
RG 59/U Type
+18 AWG
50
100
200
500
1000
0.238
X
6.05
X
11.18
Unshielded Pair
UL CL2, CATV, CM
c(UL) CM
0.144
3.66
Unshielded Pair
0.440
Premium PVC
0.010 0.25
104
Coaxial Cable
Electronics
RG 59/U Precision & Miniature Cable
75ꢀOhmꢀHigh-EndꢀCoaxialꢀCablesꢀforꢀVideo,ꢀAnalogꢀandꢀDigitalꢀApplications
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀBareꢀorꢀtinnedꢀcopper,ꢀaluminumꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀBroadcast-grade
•ꢀꢀMATV
•ꢀꢀCATV
•ꢀꢀCCTV†
•ꢀꢀPrecisionꢀvideo–analog/digital
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
ꢀ
ꢀ
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
•ꢀꢀCopperꢀperꢀASTMꢀB-3
Jacket:
•ꢀꢀPremiumꢀPVCꢀcompound
ꢀ
Insulation/Core:
Packaging:
ꢀ
ꢀ
•ꢀꢀSolidꢀpolyethyleneꢀ(PE)ꢀdesigns
•ꢀꢀFoamꢀfluoropolymerꢀ(FEP)ꢀdesign
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
27 Ga.
(7/35)
93% Tinned
Copper Braid
6.5 Ω/Mft.
20.50 67.26
66
75
1
10
1.20
2.40
4.20
5.70
8.30
C1158
Solid PE
Black PVC
RG 59/U Type
Miniature Type
1354
Stranded
50
Copper-Clad 0.100
Steel
2.54
0.150
3.81
5.00
100
200
500 13.53
1000 20.00
120.0
Ω/Mft.
20 Ga.
Solid Bare
Copper
95% Bare
Copper Braid
Shield
16.00 52.50
84
75
1
0.24
495028†
Fluoropolymer
Plenum PVC
10 1.41
50 1.83
100 2.64
200 3.84
400 5.64
RG 59/U Type
UL CMP
10.5
Ω/Mft. 0.139
3.43
0.197
2.7 Ω/Mft.
c(UL) CMP
105
Electronics
Coaxial Cable
RG 59 Serial Digital Interface Cable
75ꢀOhmꢀHigh-EndꢀCoaxialꢀCablesꢀforꢀVideo,ꢀAnalogꢀ&ꢀDigitalꢀApplications
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀTinnedꢀcopperꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀBroadcast-grade
•ꢀꢀMATV
•ꢀꢀCATV
•ꢀꢀPrecisionꢀvideo–analog/digital
•ꢀꢀSerialꢀdigitalꢀinterfaceꢀcableꢀ(SDI)
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
Jacket:
•ꢀꢀPremiumꢀPVCꢀcompound
Insulation/Core:
ꢀ
ꢀ
ꢀ
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesigns
•ꢀꢀFoamꢀfluoropolymerꢀ(FEP)ꢀdesign
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft
pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
20 Ga.
Solid Bare
Copper
Bi-Metal Foil
+95% Tinned
Copper Braid
Shield
16.30 53.40
83
75
1
135
0.29
2.70
3.80
5.47
9.30
395025
Flame-Retardant
PVC
Foam PE
RG 59/U Type
UL CMR
270
540
1500
2250 11.51
3000 13.31
c(UL) CMG
10.5 Ω/Mft.
0.146
3.71
0.242
6.15
5.05
3.5 Ω/Mft.
20 Ga.
Solid Bare
Copper
Bi-Metal Foil
+95% Tinned
Copper Braid
Shield
16.10 53.00
84
75
1
10
50
0.29
1.03
1.88
2.50
3.85
5.53
6.40
8.56
495023
Fluoropolymer
0.135 3.43
Plenum PVC
RG 59/U Type
UL CMP
100
200
400
540
1000
2250 17.50
3000 21.90
c(UL) CMP
0.199
10.5 Ω/Mft.
3.2 Ω/Mft.
106
Coaxial Cable
Electronics
RG 59/U (RGB) Multi-Channel Digital/Precision Cable
75ꢀOhmꢀHigh-EndꢀCoaxialꢀCablesꢀforꢀVideo,ꢀAnalogꢀ&ꢀMonitorꢀApplications
Product Construction:
Conductors:
Jacket:
Applications:
ꢀ
ꢀ
•ꢀꢀOuterꢀjacket:ꢀmatteꢀfinishꢀthermoplasticꢀ
elastomerꢀ(TPE)
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀBroadcast
ꢀ
•ꢀꢀSolidꢀbareꢀcopperꢀperꢀASTMꢀB-3
•ꢀꢀInnerꢀjacket:ꢀflame-retardantꢀPVC
•ꢀꢀHDTV
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
•ꢀꢀVideo–analog/digital
•ꢀꢀMonitorꢀapplications
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Packaging:
ꢀ
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Shield:
•ꢀꢀTinnedꢀcopperꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
RG 59/U SERIAL DIGITAL INTERFACE (SDI), PRECISION COAX, RISER RATED
20 Ga.
3/Cond.
Solid Bare
Copper
Bi-Metal Foil
+95% Tinned
Copper Braid
Shield
16.30 52.40
16.30 52.40
16.30 52.40
16.30 52.40
83
83
83
83
75
1
71.5
135
0.29
2.10
2.70
3.80
5.47
9.30
395025-3
Inner:
Flame-Retardant
PVC
Outer:
TPE Matte
Foam PE
0.146 3.71
RG 59/U Type
UL CMR
270
c(UL) CMG
540
1500
2250 11.51
3000 13.31
10.5
Ω/Mft.
3.5 Ω/Mft.
0.610
15.49
20 Ga.
4/Cond.
Solid Bare
Copper
Bi-Metal Foil
+95% Tinned
Copper Braid
Shield
75
75
75
1
71.5
135
0.29
2.10
2.70
3.80
5.47
9.30
395025-4
RG 59/U Type
UL CMR
Inner:
Flame-Retardant
PVC
Outer:
TPE Matte
Foam PE
0.146 3.71
270
c(UL) CMG
540
10.5
Ω/Mft.
3.5 Ω/Mft.
1500
2250 11.51
3000 13.31
0.670
17.04
20 Ga.
5/Cond.
Solid Bare
Copper
Bi-Metal Foil
+95% Tinned
Copper Braid
Shield
1
71.5
135
0.29
2.10
2.70
3.80
5.47
9.30
395025-5
RG 59/U Type
UL CMR
Inner:
Flame-Retardant
PVC
Outer:
TPE Matte
Foam PE
0.146 3.71
270
c(UL) CMG
540
10.5
Ω/Mft.
3.5 Ω/Mft.
1500
2250 11.51
3000 13.31
0.745
18.87
20 Ga.
10/Cond.
Solid Bare
Copper
Bi-Metal Foil
+95% Tinned
Copper Braid
Shield
1
71.5
135
0.29
2.10
2.70
3.80
5.47
9.30
395025-10
RG 59/U Type
UL CMR
Inner:
Flame-Retardant
PVC
Outer:
TPE Matte
Foam PE
0.146 3.71
270
c(UL) CMG
540
10.5
Ω/Mft.
3.5 Ω/Mft.
1500
2250 11.51
3000 13.31
1.110
28.19
RG 59/U MINI SERIAL DIGITAL INTERFACE (SDI), PRECISION COAX, RISER RATED
23 Ga.
3/Cond.
Solid Bare
Copper
Bi-Metal Foil
+95% Tinned
Copper Braid
Shield
16.50 54.10
83
75
75
1
71.5
135
270
540
1500 13.00
2250 16.00
3000 18.50
0.39
3.06
3.81
5.40
7.70
395031-3
RG 59/U Type
UL CMR
Inner:
Flame-Retardant
PVC
Outer:
TPE Matte
Foam PE
0.102 2.59
c(UL) CMG
20.1
Ω/Mft.
7.6 Ω/Mft.
0.415
10.58
23 Ga.
5/Cond.
Solid Bare
Copper
Bi-Metal Foil
+95% Tinned
Copper Braid
Shield
16.50 54.10
83
1
71.5
135
270
540
1500 13.00
2250 16.00
3000 18.50
0.39
3.06
3.81
5.40
7.70
395031-5
RG 59/U Type
UL CMR
Inner:
Flame-Retardant
PVC
Outer:
TPE Matte
Foam PE
0.102 2.59
c(UL) CMG
20.1
Ω/Mft.
7.6 Ω/Mft.
0.510
12.95
107
Electronics
Coaxial Cable
RG 59/U (RGB) Miniature Multi-Channel Precision Cable
75ꢀOhmꢀHigh-EndꢀCoaxialꢀCablesꢀforꢀVideo,ꢀAnalogꢀ&ꢀMonitorꢀApplications
Product Construction:
Conductors:
Jacket:
Applications:
ꢀ
ꢀ
•ꢀꢀOuterꢀjacket:ꢀmatteꢀfinishꢀthermoplasticꢀ
elastomerꢀ(TPE)
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀBroadcast
ꢀ
•ꢀꢀSolidꢀbareꢀcopperꢀperꢀASTMꢀB-3
•ꢀꢀInnerꢀjacket:ꢀflame-retardantꢀPVC
•ꢀꢀHDTV
Insulation/Core:
•ꢀꢀFoamꢀpolyethyleneꢀ(PE)ꢀdesign
•ꢀꢀVideo–analog/digital
•ꢀꢀMonitorꢀapplications
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Packaging:
ꢀ
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Shield:
•ꢀꢀTinnedꢀcopperꢀbraid
•ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
NOMINAL
AWG
SHIELD
VELOCITY OF NOMINAL
PROPAGATION, IMPEDANCE,
CAPACITANCE
ATTENUATION
CATALOG
NUMBER
SIZE
COVERAGE
pF/ft pF/m
MHz dB/100'
NOM. DCR
NOM SHLD DCR
%
Ω
RG 59/U (RGB) RISER RATED
26 Ga.
3/Cond.
Stranded
(7/34)
Bare Copper
39.7 Ω/Mft.
Bi-Metal Foil
+95% Tinned
Copper Braid
17.30 56.74
78
75
1
10
0.56
1.48
3.20
5.18
6.95
9.36
395035-3
Inner:
Foam PE
RG 59/U Type
UL CMR
Flame-Retardant
50
PVC
100
200
400
540 10.88
1000 15.79
2250 23.69
3000 27.35
c(UL) CMG
0.089
2.26
Shield
Outer:
8.6 Ω/Mft.
TPE Matte
0.435 11.05
26 Ga.
4/Cond.
Stranded
(7/34)
Bare Copper
39.7 Ω/Mft.
Bi-Metal Foil
+95% Tinned
Copper Braid
Shield
17.30 56.74
78
75
1
10
0.56
1.48
3.20
5.18
6.95
9.36
395035-4
RG 59/U Type
UL CMR
Inner:
Flame-Retardant
PVC
Outer:
TPE Matte
Foam PE
0.089 2.26
50
100
200
400
540 10.88
1000 15.79
2250 23.69
3000 27.35
c(UL) CMG
8.6 Ω/Mft.
0.460
11.70
26 Ga.
5/Cond.
Stranded
(7/34)
Bare Copper
39.7 Ω/Mft.
Bi-Metal Foil
+95% Tinned
Copper Braid
Shield
17.30 56.74
78
75
1
10
0.56
1.48
3.20
5.18
6.95
9.36
395035-5
RG 59/U Type
UL CMR
Inner:
Flame-Retardant
PVC
Outer:
TPE Matte
Foam PE
0.089 2.26
50
100
200
400
540 10.88
1000 15.79
2250 23.69
3000 27.35
c(UL) CMG
8.6 Ω/Mft.
0.480
12.19
108
Coaxial Cable
Electronics
RG 62/U Type
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀBareꢀcopperꢀbraid
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀComputer/networks
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Jacket:
•ꢀꢀPremiumꢀPVCꢀcompound
ꢀ
•ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
Insulation/Core:
Packaging:
ꢀ
ꢀ
•ꢀꢀSemi-solidꢀpolyethyleneꢀ(PE)ꢀdesign
•ꢀꢀFoamꢀfluoropolymerꢀ(FEP)ꢀdesign
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
SHIELD
NOMINAL
CAPACITANCE
pF/ft pF/m
NOMINAL
ATTENUATION
MHz dB/100'
AWG
VELOCITY OF NOMINAL
O.D.
CATALOG
NUMBER
SIZE
COVERAGE
PROPAGATION, IMPEDANCE,
INCHES mm
NOM. DCR
NOM SHLD DCR
%
Ω
22 Ga.
Solid
Copper-Clad
Steel
95% Bare
Copper Braid
2.6 Ω/Mft.
13.60 44.62
84
93
1
10
50
100
200
500
1000
0.38
0.85
1.90
2.70
3.80
5.90
8.70
C1162
Non-Contaminating
Black PVC
Semi-Solid PE
RG 62A/U Type
MIL-C-17G Type
1354
0.146
3.71
0.242
6.15
6.15
73.4 Ω/Mft.
22 Ga.
Solid
Copper-Clad
Steel
95% Bare
Copper Braid
2.6 Ω/Mft.
13.60 44.62
84
93
1
10
50
100
200
500
1000
0.38
0.85
1.90
2.70
3.80
5.90
8.70
C1164
Semi-Solid PE
0.146 3.66
Black PVC
RG 62/U Type
Computer Cable
JAN-C-17A Type
UL CL2, CM
CSA CMG
0.242
73.4 Ω/Mft.
1354
22 Ga.
Solid
Copper-Clad
Steel
95% Bare
Copper Braid
1.9 Ω/Mft.
13.00 42.65
84
93
1
10
50
100
200
500
1000
0.30
0.90
1.90
2.70
3.80
5.90
8.34
C3520
Flexguard® PVC
Natural
Fluoropolymer
0.145 3.56
RG 62/U Type
Plenum
0.201
5.11
UL CL2P, CMP
c(UL) CMP
54.7 Ω/Mft.
109
Electronics
Coaxial Cable
RG 174/U Type
Product Construction:
Conductors:
Shield:
Applications:
ꢀ
ꢀ
•ꢀꢀTinnedꢀorꢀbareꢀcopperꢀbraid
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Jacket:
•ꢀꢀPremiumꢀPVCꢀcompound
ꢀ
ꢀ •ꢀꢀCopper-cladꢀsteelꢀperꢀASTMꢀB-869
Insulation/Core:
Packaging:
ꢀ
•ꢀꢀSolidꢀpolyethyleneꢀ(PE)ꢀdesign
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
SHIELD
NOMINAL
CAPACITANCE
pF/ft pF/m
NOMINAL
ATTENUATION
MHz dB/100'
AWG
SIZE
NOM. DCR
VELOCITY OF NOMINAL
O.D.
CATALOG
NUMBER
COVERAGE
PROPAGATION, IMPEDANCE,
INCHES mm
NOM SHLD DCR
%
Ω
26 Ga.
(7/34)
Copper-Clad
Steel
88% Tinned
Copper Braid
30.80 101.05
66
50
1
10
50
1.90
3.30
5.80
8.40
C1156
RG 174/U Type
1354
Solid PE
Black PVC
10.3
Ω
/Mft.
0.103
2.62
0.060
1.52
100
97.0
Ω
/Mft.
200 12.50
500 21.21
1000 34.00
26 Ga.
(7/34)
Copper-Clad
Steel
88% Tinned
Copper Braid
Shield
30.80 101.05
66
50
1
10
50
1.90
3.30
5.80
8.40
395027
RG 174/U
1354
Solid PE
Black PVC
0.059
0.139
10.7
Ω/Mft.
0.110
2.82
100
93.0
Ω/Mft.
200 12.50
500 21.21
1000 34.00
110
Coaxial Cable
Electronics
RG 213/U Type
Product Construction:
Conductors:
Jacket:
Applications:
ꢀ
•ꢀꢀPremiumꢀnon-contaminatingꢀblackꢀPVC
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀRFꢀsignalꢀtransmission
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Packaging:
ꢀ
ꢀ
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
Insulation/Core:
packaging and color options
•ꢀꢀSolidꢀpolyethyleneꢀ(PE)ꢀdesign
Shield:
•ꢀꢀBareꢀcopperꢀbraid
INSULATION
NOMINAL
SHIELD
NOMINAL
CAPACITANCE
pF/ft pF/m
NOMINAL
ATTENUATION
MHz dB/100'
AWG
VELOCITY OF NOMINAL
MATERIAL
O.D.
CATALOG
NUMBER
SIZE
COVERAGE
PROPAGATION, IMPEDANCE,
INCHES mm
INCHES
mm
NOM. DCR
NOM SHLD DCR
%
Ω
13 Ga.
(7/21)
Bare Copper
95% Bare
Copper Braid
30.80 101.05
66
50
1
10
50
100
200
500
1000
0.18
0.62
1.50
2.10
3.00
5.03
8.20
C1176A
Solid PE
Black PVC
0.405 10.29
RG 213/U Type
MIL-C-17G Type
1354
1.2
Ω
/Mft.
1.7
Ω/Mft.
0.285
7.24
111
Electronics
Coaxial Cable
Twinaxial Cables
Product Construction:
Conductors:
Shield:
Applications:
ꢀ •ꢀꢀTinnedꢀcopperꢀbraid
ꢀ •ꢀFꢀ lexfoil® shield
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀProgrammableꢀLogicꢀControllersꢀ(PLC)
•ꢀꢀDataꢀtransmission
ꢀ
ꢀ
•ꢀꢀCopperꢀperꢀASTMꢀB-3
•ꢀꢀBroadcast
•ꢀꢀComputer
•ꢀꢀSeeꢀCoaxꢀConnectorꢀCrossꢀReference,ꢀ
pages 192-199
Jacket:
ꢀ •ꢀꢀPremiumꢀPVCꢀcompound
•ꢀꢀTinnedꢀcopperꢀperꢀASTMꢀB-33
Insulation/Core:
Packaging:
ꢀ
ꢀ
•ꢀꢀSolidꢀandꢀfoamꢀpolyethyleneꢀ(PE)ꢀ
designs
ꢀ •ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
•ꢀLꢀ o-Cap®ꢀpolypropyleneꢀ(PPE)ꢀdesign
packaging and color options
INSULATION
MATERIAL
INCHES mm
NOMINAL
O.D.
INCHES mm
NOMINAL
CAPACITANCE
pF/ft pF/m
NOMINAL
ATTENUATION
MHz dB/100'
AWG
SHIELD
VELOCITY OF NOMINAL
CATALOG
NUMBER
SIZE
COVERAGE
PROPAGATION, IMPEDANCE,
NOM. DCR
NOM SHLD DCR
%
Ω
20 Ga.
(7/28)
(1) Tinned
Copper,
(1) Bare
Copper
Solid PE
Coded:
Natural, Natural
100% Flexfoil®
+90%
Tinned Copper
Braid
15.50 50.86
66
100
1
10
50
100
200
400
0.40
1.10
2.50
4.10
6.40
10.20
C8000
Black PVC
UL CL2
2498
80°C, 300V
0.330
8.38
0.022
0.56
2.5 Ω/Mft.
9.5 Ω/Mft.
20 Ga.
(7/28)
Tinned
Copper
9.5 Ω/Mft.
Solid PE
Coded:
Natural, Blue
100% Flexfoil®
+57%
Tinned Copper
Braid
19.17 62.90
66
78
78
1
10
50
100
200
400
0.60
2.10
5.00
7.50
11.00
16.00
C8001
Blue PVC
0.242 6.15
UL CL2, CM
C(UL) CM
2464
0.020
0.51
4.1 Ω/Mft.
2582
60°C, 300V
22 Ga.
(19/34)
Tinned
Copper
15.0 Ω/Mft.
100% Flexfoil®
+22 AWG
Tinned Copper
Drain Wire
8.80 28.87
150
1
10
50
100
200
400
0.40
1.20
2.65
4.30
6.20
8.80
C8014
Lo-Cap® PPE
Coded:
Black, Yellow
2668
Black PVC
60°C, 30V
6.3 Ω/Mft.
0.051
1.30
0.360
9.14
112
Electronics
Fire Alarm/Life Safety Cable
6
Index
Page
Alarm and Security
Solutions Guide
114-116
Multi-Conductor, Unshielded,
Non-Plenum
117
118
Fire alarm systems have
Aside from the quality materials
Multi-Conductor, Unshielded,
Non-Plenum (CSA)
expanded from a rather simple
and unsophisticated business
configured upon large, electro-
mechanical devices to one
relying upon the most modern
used in these designs,
specifiers and end users of
Carol® Brand wire and cable
products have come to expect
that these cables are registered
Multi-Conductor, Shielded,
Non-Plenum
119
technologies of microprocessor and certified with the leading
Multi-Conductor, Shielded,
Non-Plenum (CSA)
and chip technology.
regulatory agencies such as
Underwriters Laboratories …
and we haven’t let you down!
120
More and more end users—
industrial, commercial as well
Multi-Conductor,
Unshielded, Plenum
121-122
123-124
125
Multi-Conductor,
Shielded, Plenum
Mid-Capacitance,
Unshielded, Non-Plenum
Mid-Capacitance,
Shielded, Non-Plenum
126
Mid-Capacitance,
Unshielded, Plenum
127
Mid-Capacitance,
Shielded, Plenum
128
assurance that the end user not products are conveniently
Multi-Paired, Unshielded,
Non-Plenum (CSA)
packaged in 1000' or 500'
129
only needs, but requires.
Iengths to assist the installer.
113
Carol® Brand Alarm & Security Solutions
General Cable’s Carol® Brand is the right solution for alarm and security
Our alarm and security cables offer solutions in all these major security
wire and cable. Carol offers as broad an offering as anyone in the industry. Our
Alarm and Security Solutions Guide makes it easier to specify and sell the right
cables for every application in this ever-growing market.
applications markets, including:
• Commercial Buildings
Many cables
also available in
• Residential Housing
There are five basic areas where alarm and security cables are used. General
Cable has the right product to serve every application, including:
ARMORED
• Business and Office Campus Environments
• Public Stadiums and Arenas
CONSTRUCTIONS
for easy plenum
installations
• Access Control
• Airport, Train, Bus and Other Transportation Hubs
• Schools, Colleges and Universities
• Video Surveillance/CCTV
• Fire Alarm and Life Safety
• Home Theater and Burglar Alarms
• Data Communications
The General Cable Alarm and Security Solutions Guide provides a quick and easy
reference tool to identify every Carol® Brand cable for the appropriate alarm and
security application. Whatever the security application need calls for, we have a
cable that delivers the performance you need.
Access Control
Applications:
Door Controllers
Prox Sensors
Key Pads
Surge
Rex/Spare
Card Readers
Gate Access
Door Contact
Power
Supply
Access
Cable
Control
Panel
Card Reader
Solution Description
4EPL4S* 4 Shielded Elements Overall Jacket Access Control Plenum
4EPL1S* 4 Elements 1 Shielded Overall Jacket Access Control Plenum
Lock Power
4ERS4S** 4 Shielded Elements Overall Jacket Access Control Riser
4ERS1S** 4 Elements 1 Shielded Overall Jacket Access Control Riser
PC
E2002S
E2004S
E2006S
E2008S
E2010S
E2012S
E2102S
E2104S
E2106S
E2108S
E2032S
E2034S
E2036S
E2038S
22/2 Conductor Shielded Riser
22/4 Conductor Shielded Riser
22/6 Conductor Shielded Riser
22/8 Conductor Shielded Riser
22/10 Conductor Shielded Riser
22/12 Conductor Shielded Riser
22/2 Conductor Shielded Plenum
22/4 Conductor Shielded Plenum
22/6 Conductor Shielded Plenum
22/8 Conductor Shielded Plenum
18/2 Conductor Shielded Riser
18/4 Conductor Shielded Riser
18/6 Conductor Shielded Riser
18/8 Conductor Shielded Riser
Cable
Solution Description
E2202S
E2204S
E2206S
E2208S
18/2 Conductor Shielded Plenum
18/4 Conductor Shielded Plenum
18/6 Conductor Shielded Plenum
18/8 Conductor Shielded Plenum
Carol® Brand Composite Access Control Cable – Plenum*
(3) Multi-Conductors • (1) Multi-Pair • Overall Jacket
60˚C 300 Volt (UL) & C(UL) Type CMP
Carol® Brand Composite Access Control Cable – Riser**
(3) Multi-Conductors • (1) Multi-Pair • Overall Jacket
60˚C 300 Volt (UL) & C(UL) Type CMR
Overall
Nominal OD
Inch (mm)
Component
Nominal OD
Inch (mm)
Insulation
Thickness
Inch (mm)
Overall
Nominal OD
Inch (mm)
Component
Nominal OD
Inch (mm)
Insulation
Thickness
Inch (mm)
Catalog
Number
Component
No.
Catalog
Number
Component
No.
Component Descriptions
Conductors Color Code
Component Descriptions
Conductors Color Code
4 Cond, 18 AWG,
Shielded
3 Pair, 22 AWG,
Shielded
2 Cond, 22 AWG,
Shielded
4 Cond, 22 AWG,
Shielded
4 Cond, 18 AWG,
Unshielded
3 Pair, 22 AWG,
Shielded
2 Cond, 22 AWG,
Unshielded
4 Cond, 22 AWG,
Unshielded
4 Cond, 18 AWG,
Shielded
3 Pair, 22 AWG,
Shielded
2 Cond, 22 AWG,
Shielded
4 Cond, 22 AWG,
Shielded
4 Cond, 18 AWG,
Unshielded
3 Pair, 22 AWG,
Shielded
2 Cond, 22 AWG,
Unshielded
4 Cond, 22 AWG,
Unshielded
1
2
3
4
1
2
3
4
White, Black, Red, Green 0.180 (4.572) 0.008 (0.2032)
1
2
3
4
1
2
3
4
White, Black, Red, Green 0.180 (4.572) 0.008 (0.2032)
White & Green, Orange &
0.195 (4.593) 0.008 (0.2032)
Brown, Red & Black
White & Green, Orange &
0.195 (4.593) 0.008 (0.2032)
Brown, Red & Black
4EPL4S
4EPL1S
0.430
0.420
4ERS4S
4ERS1S
0.430
0.420
Red, Black
0.125 (3.175) 0.008 (0.2032)
Red, Black
0.125 (3.175) 0.008 (0.2032)
White, Black, Red, Green 0.145 (3.683) 0.008 (0.2032)
White, Black, Red, Green 0.180 (4.572) 0.008 (0.2032)
White, Black, Red, Green 0.145 (3.683) 0.008 (0.2032)
White, Black, Red, Green 0.180 (4.572) 0.008 (0.2032)
White & Green, Orange &
0.195 (4.593) 0.008 (0.2032)
Brown, Red & Black
White & Green, Orange &
0.195 (4.593) 0.008 (0.2032)
Brown, Red & Black
Red, Black
0.125 (3.175) 0.008 (0.2032)
Red, Black
0.125 (3.175) 0.008 (0.2032)
White, Black, Red, Green 0.145 (3.683) 0.008 (0.2032)
White, Black, Red, Green 0.145 (3.683) 0.008 (0.2032)
114
Video Surveillance/CCTV
Applications:
CCTV
Satellites
BNC
Video
Patch Panel
Camera
Digital Video
Analog Video
Switchers/Multiplexers
Digital Recorders
Power
Supply
CDU
CATV/MATV/DBS RG 59, RG 6 and RG 11 Ratings
Cable
Solution Description
C3521
C3523
C3524
C3525
C5761
C5775
C5785
C5886
C5889
C3528
C5039
C5043
C5044
C1135
C3500
C3526
RG 6/U 18/1 FL + 95% TC CL2P
RG 6 SBC/Foil/61% TC Braid Plenum
RG 6 CCS/Foil/60% AL Braid Plenum
RG 6 CCS/Quad 60/40% AL Braid Plenum
RG 6 SBC Foil/95% BC Braid CATV/CM
RG 6 CCS/Foil/60% AL Braid CATV/CM
RG 6 CCS/Quad 60/40% AL Braid CATV/CM
RG 6 CCS/Foil/60% AL Braid CATVR/CMR
RG 6 CCS/Quad 60/40% AL Braid CATVR/CMR
RG 11 CCS/Foil/60%/AL Braid CATV/CMP Plenum
RG 11 CCS/Foil/60%/AL Braid CATV/CM
RG 11/U CCS Burial FL 60% AL
BNC Patch Panel
Monitor
Remote Keypad
Multiplexer
Recorder
RG 11/U CCS Quad Shield CL2/CM
RG 59/U CCS 95% BC Braid CM
RG 59 CCS/95% BC Braid Plenum
RG 59/U CCS AMA/80% AL Braid CLP2/CMP
HDTV/SDI—Interconnect Cables RG 59, RG 6 and RG 11 Ratings
CCTV RG 59 and RG 11 Ratings
Cable
Cable
Solution Description
Solution Description
395011
395014
495025
395025
395031
495023
RG 6 SBC/Foil/95% TC Braid CMR
C8029
C8031
495035
395058
495015
C1103
RG 6 + 18/2 Unshielded CATV/CM
RG 6/U 18/1 SBC Quad Shield 60%/40% CMR
RG 6/U 18 AWG SBC 95% Dual Foil TC Braid CMP Plenum
RG 59 SBC/Foil/95% TC Braid CMR
RG 59 Single/Miniature/Foil/95% TC Braid CMR
RG 59/U SBC/Foil/95% TC Braid CMP Plenum
RG 6/U SBC/95% + 18/2 Unshielded Pair CMP Plenum
RG 6/U 18 AWG SBC 95% BC CMP Plenum
RG 11 SBC/95% BC Braid CM
RG 11 SBC/95% BC Braid CMP Plenum
RG 59 BC/95% BC Braid CATV/CM
RG 59 SBC/95% BC Braid CATV/CM
RG 59/U STR (7/30) BC/95% + 22/2 SH Pair CCTV/CM
RG 59 + 18/2 Shielded CATV/CM
C1142
Low Skew - 4 Pair UTP Cables for RGB Video
C8025
C8027
C8028
C8030
495028
Cable
Solution Description
RG 59 + 18/2 Unshielded CATV/CM
RG 59/U SBC/95% + 18/2 Unshielded Pair CCTV Plenum
RG 59 SBC/95% BC Braid CMP Plenum
E3842S
E1842S
E3843S
E1843S
Low Skew 24/4 UTP CMP for RGB Video
Low Skew 24/4 UTP CMR for RGB Video
Low Skew 23/4 UTP CMP for RGB Video
Low Skew 23/4 UTP CMR for RGB Video
Fire Alarm and Life Safety
Surge
Applications:
Smoke Detectors
Strobes/Sirens
Pull Stations
Microprocessor/
Addressable
Strobe
Power
Supply
Controlled Systems
Siren/Horn
Cable
Solution Description
Smoke Detector
E1502S
E1504S
E1522S
E1524S
E2502S
E2504S
E2532S
E2534S
E3502S
E3504S
E3522S
E3524S
18/2 Conductor Riser FPLR
18/4 Conductor Riser FPLR
14/2 Conductor Riser FPLR
14/4 Conductor Riser FPLR
18/2 Conductor Shielded Riser FPLR
18/4 Conductor Shielded Riser FPLR
14/2 Conductor Shielded Riser FPLR
14/4 Conductor Shielded Riser FPLR
18/2 Conductor Plenum FPLP
Fire
Control
Panel
FIRE FIRE
Pull Station
PUSH
PULL
Cable
Solution Description
E3602S
E3604S
E3622S
E3624S
18/2 Conductor Shielded Plenum FPLP
18/4 Conductor Plenum FPLP
14/2 Conductor Plenum FPLP
14/4 Conductor Plenum FPLP
18/4 Conductor Shielded Plenum FPLP
14/2 Conductor Shielded Plenum FPLP
14/4 Conductor Shielded Plenum FPLP
115
Home Theater and Burglar Alarms
Cable
Applications:
Solution Description
Command® Series Twisted Pair Speaker, 22/2,
7x30 Stranding, 500' Reels
Command Series Twisted Pair Speaker, 20/2,
7x28 Stranding, 500' Reels
Command Series Twisted Pair Speaker, 18/2,
7x26 Stranding, 500' Reels
Command Series Twisted Pair Speaker, 16/2,
19x29 Stranding, 500' Reels
Command Series Twisted Pair Speaker, 14/2,
42x30 Stranding, 500' Reels
Command Series Twisted Pair Speaker, 12/2,
65x30 Stranding, 500' Reels
Intercoms
PA Systems
Sound Systems
Emergency Phones
Speakers
Burglar Alarms
Home Theater
C1000
C1001
C1002
C1003
C1004
C1005
Cable
Solution Description
C1362
C1357
C1458
C1461
C1463
C1702
C1703
C1704
C1705
C1800
22/2 Conductor Zip (not for inwall use)
18/2 Conductor Zip (not for inwall use)
16/2 Conductor Zip CL2
14/2 Conductor Zip CL2
12/2 Conductor Zip CL2
E1002S
E1004S
22/2 Conductor Riser
22/4 Conductor Riser
C4408
C4408ST
C4412
C4412ST
C4408.86.XX
22/2 Solid Conductor CMR/CMX
22/2 Stranded Conductor CMR/CMX
22/4 Solid Conductor Solid CMR/CMX
22/4 Stranded Conductor CMR/CMX
22/2 Solid Conductor CM/CMX*
14/2 Command Series Home Grade Speaker
14/4 Command Series Home Grade Speaker
16/2 Command Series Home Grade Speaker
16/4 Command Series Home Grade Speaker
Command Series “High Def” Speaker
Type NEC, 12/2, 105x32 Stranding, 500' Reels
Command Series “High Def” Speaker
Type NEC, 12/4, 105x32 Stranding, 500' Reels
Command Series “High Def” Speaker
Type NEC, 14/2, 105x34 Stranding, 500' Boxes
Command Series “High Def” Speaker
Type NEC, 14/4, 105x34 Stranding, 500' Reels
Command Series “High Def” Speaker
Type NEC, 16/2, 65x34 Stranding, 500' Boxes
Command Series “High Def” Speaker
Type NEC, 16/4, 65x34 Stranding, 500' Boxes
C4408ST.86.XX 22/2 Stranded Conductor CM/CMX*
C4412.86.XX 22/4 Solid Conductor CM/CMX*
C4412ST.86.XX 22/4 Stranded Conductor CM/CMX*
C1801
C1802
C1803
C1804
C1805
E1006S
E1008S
E1032S
E1034S
E1042S
E1044S
E1052S
E1054S
E1062S
E1064S
22/6 Conductor Riser
22/8 Conductor Riser
18/2 Conductor Riser
18/4 Conductor Riser
16/2 Conductor Riser
16/4 Conductor Riser
14/2 Conductor Riser
14/4 Conductor Riser
12/2 Conductor Riser
12/4 Conductor Riser
395031X3 23/3 Command Series RGB Cables, Solid BC, Foam PE,
Dual Foil + 95% TC Braid
395031X5 23/5 Command Series RGB Cables, Solid BC, Foam PE,
Dual Foil + 95% TC Braid
*Available Colors for Burglar Alarm Coil Packs
XX= White Gray Green Beige Yellow Dark Blue
Carol® Brand Helix/Hi-Temp® Data Communications
Applications:
Telephones
Cat 5e and 6
Connections
Networking
Cat 5e Pull-Pac® II
Cat 6 Pull-Pac® II
®
Standard packaging: 1000' Pull-Pac II
®
Standard packaging: 1000' Pull-Pac II
Pull-Pac® II
Pull-Pac® II
CMR (Non-
Plenum)
CMP
CMR (Non-
Plenum)
CMP
Jacket Color
(Plenum)
Jacket Color
(Plenum)
Workstations
Video Conferencing
Telco Closets
Home Automation
IP Cameras
Blue
CR5.30.07 CP5.30.07
Blue
CR6.30.07 CP6.30.07
White CR5.30.02 CP5.30.02
Gray CR5.30.10 CP5.30.10
White CR6.30.02 CP6.30.02
Gray CR6.30.10 CP6.30.10
Green CR5.30.06 CP5.30.06
Yellow CR5.30.05 CP5.30.05
Green CR6.30.06 CP6.30.06
Yellow CR6.30.05 CP6.30.05
Red
CR5.30.03 CP5.30.03
Red
CR6.30.03 CP6.30.03
Cat 5e Spool-Pac®
Cat 6 Spool-Pac®
®
®
Standard packaging: 1000' Spool-Pac
Standard packaging: 1000' Spool-Pac
Spool-Pac®
Spool-Pac®
CMR (Non-
Plenum)
CMP
CMR (Non-
Plenum)
CMP
Jacket Color
(Plenum)
Jacket Color
(Plenum)
Blue
CR5.A3.07 CP5.A3.07
Blue
CR6.A3.07 CP6.A3.07
White CR5.A3.02 CP5.A3.02
Gray CR5.A3.10 CP5.A3.10
White CR6.A3.02 CP6.A3.02
Gray CR6.A3.10 CP6.A3.10
Green CR5.A3.06 CP5.A3.06
Yellow CR5.A3.05 CP5.A3.05
Green CR6.A3.06 CP6.A3.06
Yellow CR6.A3.05 CP6.A3.05
Red
CR5.A3.03 CP5.A3.03
Red
CR6.A3.03 CP6.A3.03
116
Fire Alarm/Life Safety Cable
Electronics
Multi-Conductor, Unshielded, Non-Plenum
NEC Type FPLR
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVC
NOM. INSULATION
THICKNESS
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
INCHES mm
CATALOG NO. OF AWG
COND.
Jacket:
NUMBER
COND.
SIZE
STRAND
INCHES
mm
ꢀ
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀredꢀPVC
DUPLEX PARALLEL, RIBBED FOR POLARITY
•ꢀꢀSuitableꢀforꢀuseꢀfromꢀ-20°Cꢀtoꢀ+75°C
2
2
2
18
16
14
Solid
Solid
Solid
0.032
0.032
0.032
0.81
0.81
0.81
0.105 x 0.210 2.67 x 5.33
0.115 x 0.230 2.92 x 5.84
0.126 x 0.260 3.20 x 6.60
E2402S
E2404S
E2406S
•ꢀꢀRoundꢀconstructionsꢀhaveꢀsequentialꢀ
footage markings to facilitate installation
•ꢀꢀIncludesꢀripcordꢀonꢀroundꢀconstructions
ꢀ
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀWiringꢀofꢀfireꢀalarms
•ꢀꢀSmokeꢀdetectors
•ꢀꢀVoiceꢀcommunications
•ꢀꢀBurglarꢀalarms
•ꢀꢀFireꢀprotectiveꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLRꢀ
(UL:ꢀ75°C,ꢀ300V)
NOM. INSULATION
THICKNESS
NOM. JACKET
WALL
INCHES
ꢀ
ꢀ
ꢀ
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ1666ꢀFlameꢀTest
NOMINAL O.D.
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
STRAND
INCHES
mm
mm
INCHES
mm
22 AWG CONDUCTORS
Packaging:
ꢀ
2
4
6
22
22
22
Solid
Solid
Solid
0.010
0.010
0.010
0.25
0.25
0.25
0.015
0.38
0.38
0.38
0.121
0.140
0.168
3.07
3.56
4.27
E1482S
E1484S
E1486S
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
0.015
0.015
18 AWG CONDUCTORS
Color Code Chart
2
3
4
5
6
8
18
18
18
18
18
18
Solid
Solid
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.150
0.160
0.175
0.193
0.210
0.230
3.81
4.06
4.45
4.90
5.33
5.84
E1502S
E1503S
E1504S
E1505S
E1506S
E1508S
NO. OF
COND.
COLOR
Black
Red
1
2
3
4
5
6
7
8
Brown
Blue
Orange
Yellow
Violet
Gray
16 AWG CONDUCTORS
2
4
16
16
Solid
0.010
0.25
0.015
0.38
0.38
0.172
0.202
4.37
5.13
E1512S
E1514S
Solid
0.010
0.25
0.015
14 AWG CONDUCTORS
2
4
14
14
Solid
Solid
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.210
0.248
5.33
6.30
E1522S
E1524S
12 AWG CONDUCTORS
2
4
12
12
Solid
Solid
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.244
0.288
6.20
7.32
E1532S
E1534S
117
Electronics
Fire Alarm/Life Safety Cable
Multi-Conductor, Unshielded, Non-Plenum
CSA FAS 105, FPL (UL), NEC Type PLTC
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-gradeꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀpageꢀ229ꢀforꢀtheꢀCSAꢀ
NOM. INSULATION
THICKNESS
NOM. JACKET
WALL
Fire Alarm Color Code Chart
NOMINAL O.D.
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
STRAND
Jacket:
INCHES
mm
INCHES
mm
INCHES
mm
ꢀ
•ꢀꢀPremium-grade,ꢀredꢀPVC;ꢀbrownꢀasꢀanꢀ
option
6
15
20
2
22
22
22
18
18
18
18
18
18
18
18
18
18
18
18
18
18
16
16
16
16
14
14
14
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.012
0.012
0.012
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.020
0.30
0.30
0.30
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.51
0.042
0.042
0.042
0.042
0.042
0.042
0.042
0.042
0.042
0.042
0.042
0.042
0.042
0.053
0.053
0.053
0.053
0.042
0.042
0.042
0.042
0.042
0.042
0.042
0.042
1.07
1.07
1.07
1.07
1.07
1.07
1.07
1.07
1.07
1.07
1.07
1.07
1.07
1.35
1.35
1.35
1.35
1.07
1.07
1.07
1.07
1.07
1.07
1.07
1.07
0.232
0.316
0.346
0.225
0.236
0.255
0.274
0.296
0.296
0.317
0.339
0.366
0.366
0.437
0.480
0.480
0.558
0.246
0.258
0.280
0.302
0.272
0.286
0.311
0.326
5.89
8.03
8.79
5.71
5.99
6.47
6.96
7.52
7.52
8.05
8.61
9.30
9.30
11.10
12.19
12.19
14.17
6.25
6.55
7.11
7.67
6.91
7.26
7.90
8.28
C4300A
C4301A
C4302A
C4304A
C4305A
C4306A
C4307A
C4308A
C4309A
C4310A
C4312A
C4313A
C4314A
C4315A
C4316A
C4317A
C4318A
C4321A
C4322A
C4323A
C4349A
C4324A
C4325A
C4326A
C4327A
ꢀ
ꢀ
•ꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+105°C
•ꢀTꢀ RU-Mark® print legend contains
footage markings from 1000' to 0'
Applications:
•ꢀWiringꢀofꢀfireꢀalarms
•ꢀSmokeꢀalarms
•ꢀVoiceꢀcommunications
•ꢀBurglarꢀalarms
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
3
4
5
•ꢀFireꢀprotectiveꢀcircuits
•ꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
6
7
Compliances:
•ꢀNECꢀArticleꢀ725ꢀPLTCꢀ(UL:ꢀ105˚C,ꢀ300V)
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLꢀ
(UL:ꢀ105˚C,ꢀ300V)
•ꢀCSAꢀFASꢀ105ꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀC22.2ꢀNo.ꢀ208-03ꢀ(R2008)
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTU
Vertical Tray Flame Test
•ꢀPassesꢀCSAꢀFT-4ꢀVerticalꢀFlameꢀTest
ꢀ
ꢀ
8
9
10
11
15
20
21
30
2
ꢀ
ꢀ
ꢀ
ꢀ
Packaging:
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
ꢀ
packaging and color options
3
4
5
2
3
4
2
118
Fire Alarm/Life Safety Cable
Electronics
Multi-Conductor, Shielded, Non-Plenum
NEC Type FPLR
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION
THICKNESS
NOM. JACKET
WALL
NOMINAL O.D.
Shield:
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
ꢀ
ꢀ
•ꢀOꢀ verallꢀFlexfoil® polyester supported
STRAND
INCHES
mm
INCHES
mm
INCHES
mm
aluminum foil
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
22 AWG CONDUCTORS
2
4
22
22
Solid
0.010
0.25
0.015
0.38
0.38
0.126
0.145
3.20
3.68
E2482S
E2484S
Jacket:
•ꢀꢀPremium-grade,ꢀredꢀPVC
•ꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
•ꢀꢀSequentialꢀfootageꢀmarkingsꢀtoꢀfacilitateꢀ
installation
•ꢀꢀIncludesꢀripcord
Solid
0.010
0.25
0.015
ꢀ
ꢀ
ꢀ
18 AWG CONDUCTORS
2
3
4
6
8
18
18
18
18
18
Solid
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.158
0.165
0.183
0.216
0.235
4.01
4.19
4.65
5.49
5.97
E2502S
E2503S
E2504S
E2506S
E2508S
ꢀ
Applications:
•ꢀꢀWiringꢀofꢀfireꢀalarms
•ꢀꢀSmokeꢀalarms
•ꢀꢀVoiceꢀcommunications
•ꢀꢀBurglarꢀalarms
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
16 AWG CONDUCTORS
•ꢀꢀFireꢀprotectiveꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
2
4
16
16
Solid
0.010
0.25
0.015
0.38
0.38
0.180
0.210
4.57
5.33
E2522S
E2524S
Solid
0.010
0.25
0.015
Compliances:
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLRꢀ
(UL:ꢀ75°C,ꢀ300V)
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ1666ꢀFlameꢀTest
14 AWG CONDUCTORS
ꢀ
2
4
14
14
Solid
0.013
0.33
0.015
0.38
0.38
0.218
0.253
5.54
6.43
E2532S
E2534S
ꢀ
ꢀ
ꢀ
Solid
0.013
0.33
0.015
12 AWG CONDUCTORS
2
4
12
12
Solid
0.013
0.33
0.015
0.38
0.38
0.252
0.293
6.40
7.44
E2542S
E2544S
Packaging:
Solid
0.013
0.33
0.015
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart
NO. OF
COND.
COLOR
Black
Red
Brown
Blue
Orange
Yellow
Violet
Gray
1
2
3
4
5
6
7
8
119
Electronics
Fire Alarm/Life Safety Cable
Multi-Conductor, Shielded, Non-Plenum
CSA FAS 105, FPL (UL), NEC Type PLTC
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18-12ꢀAWGꢀfullyꢀannealed,ꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀpageꢀ229ꢀforꢀtheꢀCSAꢀ
NOM. INSULATION NOM. JACKET
Fire Alarm Color Code Chart
DRAIN
WIRE
AWG
NOMINAL O.D.
THICKNESS
THICKNESS
CATALOG NO. OF AWG
COND.
Shield:
NUMBER
COND. SIZE STRAND
INCHES mm INCHES mm
INCHES
mm
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
25%ꢀoverlap,ꢀfoilꢀfacingꢀout
•ꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
2
3
18
18
18
18
18
18
18
18
18
18
16
16
16
16
14
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
22
22
22
22
22
22
22
22
22
22
22
22
22
22
16
16
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.053 1.35
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.015 0.38 0.042 1.07
0.020 0.51 0.042 1.07
0.230
0.241
0.260
0.279
0.301
0.301
0.322
0.344
0.371
5.84
6.12
6.60
7.09
7.65
7.65
8.18
8.74
9.42
C4334A
C4335A
C4336A
C4337A
C4338A
C4339A
C4340A
C4341A
C4342A
C4343A
C4344A
C4345A
C4346A
C4350A
C4347A
C4348A
Jacket:
4
ꢀ
•ꢀꢀPremium-grade,ꢀredꢀPVC;ꢀbrownꢀasꢀanꢀ
option
•ꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+105°C
•ꢀTꢀ RU-Mark® print legend contains
5
ꢀ
ꢀ
6
footage markings from 1000' to 0'
7
Applications:
•ꢀWiringꢀofꢀfireꢀalarms
•ꢀSmokeꢀalarms
•ꢀVoiceꢀcommunications
•ꢀBurglarꢀalarms
8
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
9
10
30
2
0.563 14.30
•ꢀFireꢀprotectiveꢀcircuits
•ꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
0.251
0.263
0.285
0.307
0.277
0.331
6.37
6.68
7.24
7.80
7.04
8.41
3
Compliances:
•ꢀNECꢀArticleꢀ725ꢀPLTCꢀ(UL:ꢀ105˚C,ꢀ300V)
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLꢀ
(UL:ꢀ105˚C,ꢀ300V)
•ꢀCSAꢀFASꢀ105ꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀC22.2ꢀNo.ꢀ208-03ꢀ(R2008)
ꢀ
ꢀ
4
5
ꢀ
ꢀ
ꢀ
2
2
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTU
Vertical Tray Flame Test
ꢀ
•ꢀPassesꢀCSAꢀFT-4ꢀVerticalꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
120
Fire Alarm/Life Safety Cable
Electronics
Multi-Conductor, Unshielded, Plenum
NEC Type FPLP
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
PVC
NOM. INSULATION
THICKNESS
NOM. JACKET
WALL
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOMINAL O.D.
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
Jacket:
STRAND
INCHES
mm
INCHES
mm
INCHES
mm
ꢀ
ꢀ
ꢀ
•ꢀPꢀ remium-grade,ꢀredꢀFlexguard® PVC
•ꢀTemperatureꢀrange:ꢀ0°Cꢀtoꢀ+75°C
22 AWG CONDUCTORS
2
4
22
22
Solid
0.010
0.25
0.015
0.38
0.38
0.121
0.137
3.07
3.47
E3482S
E3484S
•ꢀꢀSequentialꢀfootageꢀmarkingsꢀtoꢀfacilitateꢀ
installation
•ꢀꢀIncludesꢀripcord
Solid
0.010
0.25
0.015
ꢀ
18 AWG CONDUCTORS
Applications:
•ꢀꢀWiringꢀofꢀfireꢀalarms
•ꢀꢀSmokeꢀdetectors
•ꢀꢀVoiceꢀcommunications
•ꢀꢀBurglarꢀalarms
2
3
4
6
18
18
18
18
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.155
0.160
0.175
0.211
3.81
4.06
4.45
5.36
E3502S
E3503S
E3504S
E3506S
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀFireꢀprotectiveꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
16 AWG CONDUCTORS
2
4
16
16
Solid
0.010
0.25
0.015
0.38
0.38
0.172
0.202
4.37
5.13
E3512S
E3514S
Compliances:
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLPꢀ
(UL:ꢀ75°C,ꢀ300V)
ꢀ
Solid
0.010
0.25
0.015
14 AWG CONDUCTORS
ꢀ
ꢀ
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
2
4
14
14
Solid
0.012
0.30
0.015
0.38
0.38
0.205
0.243
5.21
6.17
E3522S
E3524S
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Solid
0.012
0.30
0.015
12 AWG CONDUCTORS
Packaging:
2
4
12
12
Solid
0.012
0.30
0.015
0.38
0.38
0.244
0.284
6.20
7.21
E3532S
E3534S
ꢀ
ꢀ •ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Solid
0.012
0.30
0.015
Color Code Chart
NO. OF
COND.
COLOR
Black
Red
1
2
3
4
5
6
Brown
Blue
Orange
Yellow
121
Electronics
Fire Alarm/Life Safety Cable
Multi-Conductor, Unshielded, Plenum
NECꢀTypeꢀFPLP,ꢀPVDFꢀJacketed
Product Construction
Conductor:
ꢀ
•ꢀꢀ18ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper to ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
PVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.*
C-C
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
Jacket:
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
CAP.
ꢀ
ꢀ
ꢀ
•ꢀꢀFluoropolymer,ꢀred
•ꢀꢀTemperatureꢀrange:ꢀ-10°Cꢀtoꢀ+75°C
•ꢀꢀIncludesꢀripcord
NUMBER COND SIZE STRAND
IN
mm
IN
mm
IN
mm
pF/ft
2
4
2
4
2
4
2
4
18
18
16
16
14
14
12
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.013
0.013
0.013
0.013
0.23
0.23
0.23
0.23
0.31
0.31
0.31
0.31
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25 0.140
0.25 0.156
0.25 0.133
0.25 0.186
0.25 0.170
0.25 0.224
0.25 0.194
0.25 0.261
3.56
3.96
3.38
4.72
4.32
5.69
4.93
6.63
29.0
29.0
31.0
31.0
31.0
31.0
35.0
35.0
C3200
C3201
C3210
C3211
C3220
C3223
C3224
C3225
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀFireꢀalarmꢀsystems
•ꢀꢀVoiceꢀcommunications
•ꢀꢀSmokeꢀdetectors
•ꢀꢀPullꢀboxes
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Compliances:
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLPꢀ
(UL:ꢀ75°C,ꢀ300V)
ꢀ
ꢀ
ꢀ
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
*Capacitance between conductors
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Color Code Chart
Features:
NO. OF
ꢀ
•ꢀꢀAbrasion-,ꢀchemical-ꢀandꢀwater-resistantꢀ
COND.
COLOR
Black
Red
jacket
1
2
3
4
ꢀ
•ꢀꢀSequentiallyꢀfootageꢀmarked
Packaging:
Brown
Blue
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
122
Fire Alarm/Life Safety Cable
Electronics
Multi-Conductor, Shielded, Plenum
NEC Type FPLP
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
PVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION
THICKNESS
NOM. JACKET
WALL
NOMINAL O.D.
Shield:
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
ꢀ
ꢀ
•ꢀOꢀ verallꢀFlexfoil® polyester supported
STRAND
INCHES
mm
INCHES
mm
INCHES
mm
aluminum foil
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
22 AWG CONDUCTORS
2
22
Solid
0.010
0.25
0.015
0.38
0.126
3.20
E3542S
Jacket:
18 AWG CONDUCTORS
ꢀ
ꢀ
ꢀ
•ꢀPꢀ remium-grade,ꢀredꢀFlexguard® PVC
•ꢀꢀSuitableꢀforꢀuseꢀfromꢀ0°Cꢀtoꢀ+75°C
2
3
4
6
18
18
18
18
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.158
0.165
0.183
0.216
4.01
4.19
4.65
5.49
E3602S
E3603S
E3604S
E3606S
•ꢀꢀSequentialꢀfootageꢀmarkingsꢀtoꢀfacilitateꢀ
installation
•ꢀꢀIncludesꢀripcord
ꢀ
Applications:
•ꢀꢀWiringꢀofꢀfireꢀalarms
•ꢀꢀSmokeꢀdetectors
•ꢀꢀVoiceꢀcommunications
•ꢀꢀBurglarꢀalarms
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
16 AWG CONDUCTORS
2
4
16
16
Solid
0.010
0.25
0.015
0.38
0.38
0.180
0.210
4.57
5.33
E3612S
E3614S
Solid
0.010
0.25
0.015
•ꢀꢀFireꢀprotectiveꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
14 AWG CONDUCTORS
2
4
14
14
Solid
0.012
0.30
0.015
0.38
0.38
0.210
0.248
5.33
6.30
E3622S
E3624S
Compliances:
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLPꢀ
(UL:ꢀ75°C,ꢀ300V)
Solid
0.012
0.30
0.015
ꢀ
12 AWG CONDUCTORS
ꢀ
ꢀ
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
2
4
12
12
Solid
0.012
0.30
0.015
0.38
0.38
0.252
0.300
6.40
7.62
E3632S
E3634S
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Solid
0.012
0.30
0.015
Packaging:
Color Code Chart
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
NO. OF
COND.
COLOR
Black
Red
1
2
3
4
5
6
Brown
Blue
Orange
Yellow
123
Electronics
Fire Alarm/Life Safety Cable
Multi-Conductor, Shielded, Plenum
NECꢀTypeꢀFPLP,ꢀPVDFꢀJacketed
Product Construction
Conductor:
ꢀ
•ꢀꢀ18ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
PVC
NOM.
INSULATION
THICKNESS
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. JACKET
THICKNESS
NOMINAL CAP. *
pF/ft
NOMINAL O.D.
CATALOG NO. OF AWG COND.
Shield:
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
A
B
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil,
25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
2
4
2
4
2
4
2
4
18
18
16
16
14
14
12
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.010 0.25 0.010 0.25 0.149 3.78 50.5
90.8
80.0
C3260
C3261
C3270
C3271
C3280
C3284
C3282
C3283
0.010 0.25 0.010 0.25 0.168 4.27 44.5
0.010 0.25 0.010 0.25 0.169 4.29 58.0
0.010 0.25 0.010 0.25 0.194 4.93 50.0
0.013 0.33 0.010 0.25 0.214 5.44 55.5
0.013 0.33 0.010 0.25 0.245 6.22 48.0
0.013 0.33 0.010 0.25 0.234 5.94 65.0
0.013 0.33 0.010 0.25 0.284 7.21 55.0
Jacket:
104.0
90.0
ꢀ
ꢀ
ꢀ
•ꢀꢀFluoropolymer,ꢀred
•ꢀꢀTemperatureꢀrange:ꢀ-10°Cꢀtoꢀ+75°C
•ꢀꢀIncludesꢀripcord
100.0
87.0
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀFireꢀalarmꢀsystems
•ꢀꢀVoiceꢀcommunications
•ꢀꢀSmokeꢀdetectors
•ꢀꢀPullꢀboxes
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
116.0
99.0
*A - Capacitance between conductors
*B - Capacitance between one conductor and other conductors connected to shield
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLPꢀ
(UL:ꢀ75°C,ꢀ300V)
Color Code Chart
ꢀ
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
NO. OF
COND.
COLOR
Black
Red
Features:
ꢀ
ꢀ
1
2
3
4
•ꢀꢀAbrasion-,ꢀchemical-resistantꢀjacket
•ꢀꢀSequentiallyꢀfootageꢀmarked
Brown
Blue
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
124
Fire Alarm/Life Safety Cable
Electronics
Mid-Capacitance, Unshielded, Non-Plenum
NEC Type FPL for Microprocessor-Controlled Systems
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.*
C-C
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
Jacket:
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
CAP.
ꢀ
ꢀ
•ꢀꢀPVC,ꢀred
NUMBER COND SIZE STRAND
IN
mm
IN
mm
IN
mm
pF/ft
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+60°C
Applications:
2
4
2
4
2
2
18
18
16
16
14
12
Solid
Solid
Solid
Solid
Solid
Solid
0.014
0.014
0.016
0.016
0.018
0.020
0.36
0.36
0.41
0.41
0.46
0.51
0.020
0.020
0.020
0.020
0.020
0.020
0.51 0.177
0.51 0.205
0.51 0.206
0.51 0.240
0.51 0.240
0.51 0.282
4.50
5.21
5.23
6.10
6.10
7.16
16.5
16.5
17.5
17.5
18.0
19.0
C0471
C0485
C0473
C0486
C0491
C0492
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀAddressableꢀfireꢀalarmꢀsystems
•ꢀꢀFireꢀalarmꢀsystems
•ꢀꢀVoiceꢀcommunications
•ꢀꢀSmokeꢀdetectors
•ꢀꢀPullꢀboxes
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Compliances:
*Capacitance between conductors
ꢀ
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPL
(UL:ꢀ60°C,ꢀ300V)
ꢀ
ꢀ
ꢀ
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀPassesꢀULꢀ70,000ꢀBTUꢀVerticalꢀTrayꢀ
Color Code Chart
NO. OF
COND.
COLOR
Black
Red
Flame Test
1
2
3
4
Features:
ꢀ
•ꢀꢀRedꢀPVCꢀjacketꢀforꢀeasyꢀcriticalꢀcircuitꢀ
identification
Brown
Blue
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
125
Electronics
Fire Alarm/Life Safety Cable
Mid-Capacitance, Shielded, Non-Plenum
NEC Type FPL for Microprocessor-Controlled Systems
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
ꢀ
polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
ꢀ
INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL CAP. *
pF/ft
NOMINAL O.D.
CATALOG NO. OF AWG COND.
Shield:
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
A
B
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
2
4
2
4
2
4
2
4
18
18
16
16
14
14
12
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.014 0.36 0.020 0.51 0.182 4.88 27.0
49.0
44.0
52.0
46.5
55.5
49.5
60.0
52.5
C0472
C0494
C0474
C0495
C0475
C0496
C0476
C0497
0.014 0.36 0.020 0.51 0.210 5.33 24.5
0.016 0.41 0.020 0.51 0.214 5.44 29.0
0.016 0.41 0.020 0.51 0.246 6.25 26.0
0.018 0.46 0.020 0.51 0.245 6.22 31.0
0.018 0.46 0.020 0.51 0.287 7.29 27.5
0.020 0.51 0.020 0.51 0.287 7.29 33.0
0.020 0.51 0.020 0.51 0.337 8.56 29.0
Jacket:
•ꢀꢀPVC,ꢀred
•ꢀꢀTemperatureꢀrange:ꢀ0°Cꢀtoꢀ+60°C
ꢀ
ꢀ
Applications:
•ꢀꢀAddressableꢀfireꢀalarmꢀsystems
•ꢀꢀFireꢀalarmꢀsystems
•ꢀꢀVoiceꢀcommunications
•ꢀꢀSmokeꢀdetectors
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPullꢀboxes
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
*A - Capacitance between conductors
*B - Capacitance between one conductor and other conductors connected to shield
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPL
(UL:ꢀ60°C,ꢀ300V)
Color Code Chart
ꢀ
ꢀ
ꢀ
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀPassesꢀULꢀ70,000ꢀBTUꢀVerticalꢀTrayꢀ
NO. OF
COND.
COLOR
Black
Red
1
2
3
4
Flame Test
Brown
Blue
Features:
ꢀ
•ꢀꢀRedꢀPVCꢀjacketꢀforꢀeasyꢀcriticalꢀcircuitꢀ
identification
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
126
Fire Alarm/Life Safety Cable
Electronics
Mid-Capacitance, Unshielded, Plenum
NEC Type FPLP for Microprocessor-Controlled Systems
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
fluoropolymer
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.*
C-C
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
CAP.
Jacket:
NUMBER COND SIZE STRAND
IN
mm
IN
mm
IN
mm
pF/ft
ꢀ
ꢀ
ꢀ
•ꢀPꢀ remium-grade,ꢀredꢀFlexguard® PVC
•ꢀꢀTemperatureꢀrange:ꢀ0°Cꢀtoꢀ+75°C
•ꢀꢀIncludesꢀripcord
2
4
2
4
2
4
2
4
18
18
16
16
14
14
12
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.014
0.014
0.016
0.016
0.018
0.018
0.020
0.020
0.36
0.36
0.41
0.41
0.46
0.46
0.51
0.51
0.015
0.015
0.015
0.015
0.020
0.020
0.020
0.020
0.38 0.172
0.38 0.195
0.38 0.196
0.38 0.231
0.51 0.242
0.51 0.286
0.51 0.282
0.51 0.333
4.37
4.95
4.98
5.87
6.15
7.26
7.16
8.45
19.0
19.0
20.0
20.0
20.0
20.0
22.0
22.0
C3240
C3242
C3241
C3243
C3244
C3245
C3246
C3247
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀAddressableꢀfireꢀalarmꢀsystems
•ꢀꢀFireꢀalarmꢀsystems
•ꢀꢀVoiceꢀcommunications
•ꢀꢀSmokeꢀdetectors
•ꢀꢀPullꢀboxes
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Compliances:
*Capacitance between conductors
ꢀ
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLPꢀ
(UL:ꢀ75°C,ꢀ300V)
ꢀ
ꢀ
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
Color Code Chart
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
NO. OF
COND.
COLOR
Black
Red
Features:
ꢀ
1
2
3
4
•ꢀꢀRedꢀPVCꢀjacketꢀforꢀeasyꢀcriticalꢀcircuitꢀ
identification
Brown
Blue
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
127
Electronics
Fire Alarm/Life Safety Cable
Mid-Capacitance, Shielded, Plenum
NEC Type FPLP for Microprocessor-Controlled Systems
Product Construction
Conductor:
ꢀ
•ꢀꢀ18ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
fluoropolymer
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM.
INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL CAP. *
pF/ft
NOMINAL O.D.
CATALOG NO. OF AWG COND.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
Shield:
A
B
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil,
25%ꢀoverlap,ꢀminimumꢀ
ꢀꢀ •ꢀSꢀ trandedꢀtinnedꢀcopperꢀdrainꢀwire
2
4
2
4
2
4
2
4
18
18
16
16
14
14
12
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.014 0.36 0.015 0.38 0.172 4.37 31.0
56.0
50.0
59.0
53.0
63.0
56.0
68.0
60.0
C3167
C3170
C3168
C3171
C3172
C3173
C3174
C3175
0.014 0.36 0.015 0.38 0.202 5.13 28.0
0.016 0.41 0.015 0.38 0.203 5.16 33.0
0.016 0.41 0.015 0.38 0.238 6.05 29.0
0.018 0.46 0.020 0.51 0.247 6.27 35.0
0.018 0.46 0.020 0.51 0.289 7.34 30.0
0.020 0.51 0.020 0.51 0.289 7.34 38.0
0.020 0.51 0.020 0.51 0.340 8.64 33.0
Jacket:
ꢀ
ꢀ
ꢀ
•ꢀPꢀ remium-grade,ꢀredꢀFlexguard® PVC
•ꢀꢀTemperatureꢀrange:ꢀ0°Cꢀtoꢀ+75°C
•ꢀꢀIncludesꢀripcord
Applications:
•ꢀꢀAddressableꢀfireꢀalarmꢀsystems
•ꢀꢀFireꢀalarmꢀsystems
•ꢀꢀVoiceꢀcommunications
•ꢀꢀSmokeꢀdetectors
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
*A - Capacitance between conductors
*B - Capacitance between one conductor and other conductors connected to shield
•ꢀꢀPullꢀboxes
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Compliances:
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLPꢀ
(UL:ꢀ75°C,ꢀ300V)
Color Code Chart
ꢀ
NO. OF
COND.
COLOR
Black
Red
ꢀ
ꢀ
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
1
2
3
4
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6 Steiner Tunnel Fire Tests for Plenum
Applications
Brown
Blue
Features:
ꢀ
•ꢀꢀRedꢀPVCꢀjacketꢀforꢀeasyꢀcriticalꢀcircuitꢀ
identification
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
128
Fire Alarm/Life Safety Cable
Electronics
Multi-Paired, Unshielded, Non-Plenum
CSA FAS 105, FPL (UL), NEC Type PLTC
Product Construction
Conductor:
ꢀ
•ꢀꢀ22ꢀandꢀ18ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcolor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀpageꢀ229ꢀforꢀtheꢀCSAꢀ
Fire Alarm Color Code Chart
Jacket:
ꢀ
•ꢀꢀPremium-grade,ꢀredꢀPVC;ꢀbrownꢀasꢀanꢀ
option
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL O.D.
ꢀ
ꢀ
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+105°C
•ꢀTꢀ RU-Mark® print legend contains
footage markings from 1000' to 0'
CATALOG NO. OF AWG
COND.
NUMBER
PAIRS SIZE STRAND
INCHES
mm
INCHES
mm
INCHES
mm
3
6
22
22
22
22
22
18
Solid
Solid
Solid
Solid
Solid
Solid
0.012
0.012
0.012
0.012
0.012
0.015
0.30
0.30
0.30
0.30
0.30
0.38
0.042
0.042
0.053
0.053
0.063
0.053
1.07
1.07
1.35
1.35
1.60
1.35
0.279
0.350
0.474
0.523
0.672
0.487
7.09
8.89
C4328A
C4329A
C4330A
C4331A
C4332A
C4333A
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀWiringꢀofꢀfireꢀalarms
•ꢀꢀSmokeꢀalarms
•ꢀꢀVoiceꢀcommunications
•ꢀꢀBurglarꢀalarms
•ꢀꢀFireꢀprotectionꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
12
15
27
6
12.04
13.28
17.07
12.37
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀPLTCꢀ(UL:ꢀ105˚C,ꢀ300V)
ꢀ
•ꢀꢀNECꢀArticleꢀ760ꢀTypeꢀFPLꢀ
(UL:ꢀ105˚C,ꢀ300V)
ꢀ
ꢀ
ꢀ
•ꢀꢀCSAꢀFASꢀ105ꢀ(CSA:ꢀ105˚C,ꢀ300V)
•ꢀC22.2ꢀNo.ꢀ208-03ꢀ(R2008)
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
Vertical Tray Flame Test
ꢀ
•ꢀꢀPassesꢀCSAꢀFT-4ꢀVerticalꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
129
Electronics
Sound, Alarm & Security Cable
7
Index
Page
131
132
133
134
Composite Access
Control Cable
Composite Access
Control Cable, Plenum
The sound and security
environments, including
Composite Access
Control Cable, Riser
industry in the United States
has grown from a simple and
unsophisticated business,
begun some 45 years ago,
to one which has developed
technology to the degree that
specialized wires and cables are
now much in demand.
telephone systems, intercoms,
burglar alarms, business
machines and thermostats.
Multi-Conductor,
Unshielded, Riser
Aside from the quality materials
used in these designs,
Multi-Conductor,
Shielded, Riser
135
136
137
specifiers and users of Carol®
Brand wire and cable products
have come to expect that
these cables are registered
and certified with the leading
regulatory agencies such as
Underwriters Laboratories …
Multi-Conductor,
Unshielded, Plenum
No longer are the security and
sound industries characterized
by large electromechanical
relays and large contactors;
Multi-Conductor,
Shielded, Plenum
today these circuits incorporate and we haven’t let you down!
the latest in microprocessors
Telephone Station/Intercom
& Speaker/Burglar Alarm
138
139
140
141
142
Carol® Brand designs have
and solid state devices to not
proven themselves in the area
only improve functionality but
Antenna Rotor
of sound and security over
also to guarantee performance.
time; most are fabricated with
solid or stranded, bare copper
conductors with insulations
and jackets of premium grades
of PVC. We offer both parallel
and cabled designs both with
and without shields. Sequential
Low-Voltage Sprinkler Wire
Thermostat Wire Type LVT
Thermostat Wire Type CL2
As a major wire producer, our
role is to ensure that the wires
and cables that go into these
systems are as reliable as
the other components … the
net result is a fully integrated
Thermostat Wire,
Unjacketed
143
144
145
system which will provide peace footage markings on the jackets
of mind to the system user.
are offered on all products.
Carol® Helix/Hi-Temp®
Category 6 Cable
Also in this section are General General Cable Carol® Brand
Cable’s Carol® Brand wire and
cable designs suitable for a
variety of applications, both
in industrial and commercial
products are conveniently
packaged in 1000' or 500'
Iengths to assist the installer.
Carol® Helix/Hi-Temp®
Category 5e Cable
130
E L E C T R O N I C S P R O D U C T B U L L E T I N
®
Carol Brand Composite
Access Control Cable
General Cable’s Carol® Brand Composite
Access Control Cable is manufactured for
use in Building Access & Control. The cable is
designed to allow for a single cable run that
incorporates the four components required
for card readers, door contacts, locking power
and retinal scanners in commercial buildings,
distribution centers, manufacturing facilities
and government buildings.
The cables are installer friendly, as they save
time and money on installation. With multiple
cables under one jacket, time is saved in
preparation and setup, pulling and termination.
The convenience of these cables at installation
makes them a popular choice for multiple
Access Control applications.
When your job requires Access Control cable,
think of Carol® Brand cables first. Remember, you
can always Demand Better...Expect More™
with General Cable Carol® Brand Electronic
Cables. We manufacture over 1,300 standard
electronic cables that we can ship direct from
stock, and we have the technical staff and design
expertise to meet any custom cable requirement.
Special Application Cable
Hook-Up Wire
Plenum Cable
Coaxial Cable
Microphone Cable
Computer Cable
General Purpose Cable
Multi-Conductor Communication
& Control Cable
Multi-Paired Communication
& Control Cable
Fire Alarm Cable
For more information, contact your local General Cable representative.
Sound & Security Cable
131
Electronics
Sound, Alarm and Security Cable
Composite Access Control Cable, Plenum
NEC Type CMP, UL, c(UL)
Product Construction:
Conductor:
•ꢀꢀStrandedꢀbareꢀcopper
ꢀ
Jacket:
ꢀ
ꢀ
ꢀ
•ꢀFꢀ lexguard® PVC
•ꢀTemperatureꢀrange:ꢀ0˚Cꢀtoꢀ+60˚C
•ꢀꢀIndividualꢀelementsꢀmarkedꢀforꢀ
application (see diagram below)
ꢀ
ꢀ
•ꢀꢀYellowꢀoverallꢀjacket
Shields:
ꢂVERAꢁꢁ
CꢂMPꢂNENꢀ
NꢂMINAꢁ ꢂ.D.
INCH (MM)
INSUꢁAꢀIꢂN
ꢀHICkNESS
INCH (MM)
•ꢀꢀChoiceꢀbetweenꢀallꢀ4ꢀelementsꢀshieldedꢀ
or just the 3-pair element shielded
CAꢀAꢁꢂg NꢂMINAꢁ ꢂ.D. CꢂMPꢂNENꢀ
CꢂMPꢂNENꢀ
DESCRIPꢀIꢂNS
CꢂNDUCꢀꢂRS
CꢂꢁꢂR CꢂDE
NUMBER
INCH (MM)
Nꢂ.
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSecurityꢀsystems
•ꢀꢀAccessꢀcontrol
•ꢀꢀCardꢀreaderꢀ
•ꢀꢀDoorꢀcontrol
4 Cond, 18 AWG,
Shielded
White, Black,
Red, Green
1
0.180 (4.572)
0.195 (4.593)
0.125 (3.175)
0.145 (3.683)
0.180 (4.572)
0.195 (4.593)
0.125 (3.175)
0.145 (3.683)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
White & Green,
Orange & Brown,
Red & Black
3 Pair, 22 AWG,
Shielded
2
3
4
1
2
3
4
•ꢀꢀREX
0.430
4EPL4S
•ꢀꢀPower-limitedꢀcontrols
2 Cond, 22 AWG,
Shielded
Red, Black
Compliances:
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMPꢀ(UL),ꢀc(UL)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
4 Cond, 22 AWG,
Shielded
White, Black,
Red, Green
Packaging:
ꢀ
4 Cond, 18 AWG,
Unshielded
White, Black,
Red, Green
•ꢀꢀ500'ꢀandꢀ1000'ꢀreels
White & Green,
Orange & Brown,
Red & Black
3 Pair, 22 AWG,
Shielded
0.420
4EPL1S
2 Cond, 22 AWG,
Unshielded
Red, Black
4 Cond, 22 AWG,
Unshielded
White, Black,
Red, Green
Rex/Spare
Jacket Color Coding & Component Application
Door Contact
Jacket Color Component
CableType
Application
Gray
1
2
3
4
4 Conductor, 18 AWG
3 Pair, 22 AWG
Lock Power
Card Reader
Door Contact
Rex/Spare
Orange
White
Blue
2 Conductor, 22 AWG
4 Conductor, 22 AWG
Card Reader
ꢁocꢃ Power
132
Sound, Alarm and Security Cable
Electronics
Composite Access Control Cable, Riser
NEC Type CMR, UL, c(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀStrandedꢀbareꢀcopper
Jacket:
ꢀ
ꢀ
ꢀ
•ꢀꢀPVC
•ꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+60˚C
•ꢀꢀIndividualꢀelementsꢀmarkedꢀforꢀ
application (see diagram below)
ꢀ
ꢀ
•ꢀꢀBlueꢀoverallꢀjacket
Shields:
ꢂVERAꢁꢁ
CꢂMPꢂNENꢀ
NꢂMINAꢁ ꢂ.D.
INCH (MM)
INSUꢁAꢀIꢂN
ꢀHICkNESS
INCH (MM)
•ꢀꢀChoiceꢀbetweenꢀallꢀ4ꢀelementsꢀshieldedꢀ
or just the 3-pair shielded
CAꢀAꢁꢂg NꢂMINAꢁ ꢂ.D. CꢂMPꢂNENꢀ
CꢂMPꢂNENꢀ
DESCRIPꢀIꢂNS
CꢂNDUCꢀꢂRS
CꢂꢁꢂR CꢂDE
NUMBER
INCH (MM)
Nꢂ.
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSecurityꢀsystems
•ꢀꢀAccessꢀcontrol
•ꢀꢀCardꢀreaderꢀ
•ꢀꢀDoorꢀcontrol
4 Cond, 18 AWG,
Shielded
White, Black,
Red, Green
1
0.180 (4.572)
0.195 (4.593)
0.125 (3.175)
0.145 (3.683)
0.180 (4.572)
0.195 (4.593)
0.125 (3.175)
0.145 (3.683)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
0.008 (0.2032)
White & Green,
Orange & Brown,
Red & Black
3 Pair, 22 AWG,
Shielded
2
3
4
1
2
3
4
•ꢀꢀREX
0.430
4ERS4S
•ꢀꢀPower-limitedꢀcontrols
2 Cond, 22 AWG,
Shielded
Red, Black
Compliances:
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ(UL),ꢀc(UL)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
4 Cond, 22 AWG,
Shielded
White, Black,
Red, Green
Packaging:
ꢀ
4 Cond, 18 AWG,
Unshielded
White, Black,
Red, Green
•ꢀꢀ500'ꢀandꢀ1000'ꢀreels
White & Green,
Orange & Brown,
Red & Black
3 Pair, 22 AWG,
Shielded
0.420
4ERS1S
2 Cond, 22 AWG,
Unshielded
Red, Black
4 Cond, 22 AWG,
Unshielded
White, Black,
Red, Green
Rex/Spare
Jacket Color Coding & Component Application
Door Contact
Jacket Color Component
CableType
4 Conductor, 18 AWG
3 Pair, 22 AWG
Application
Lock Power
Card Reader
Door Contact
Rex/Spare
Gray
1
2
3
4
Orange
White
Blue
2 Conductor, 22 AWG
4 Conductor, 22 AWG
Card Reader
ꢁocꢃ Power
133
Electronics
Sound, Alarm and Security Cable
Multi-Conductor, Unshielded, Riser
NEC Type CMR and/or CL3R
Product Construction:
Conductor:
ꢀ
•ꢀꢀStrandedꢀorꢀsolidꢀbareꢀcopperꢀperꢀ
ASTM B-3, B-8 and B-286
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Jacket:
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
NꢂM. JACkEꢀ
WAꢁꢁ
NꢂMINAꢁ ꢂ.D.
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀgrayꢀPVC
CAꢀAꢁꢂg Nꢂ. ꢂF AWg
CꢂND.
NUMBER CꢂND. SIZE SꢀRAND INCHES
mm
INCHES
mm
INCHES
mm
•ꢀꢀSequentialꢀfootageꢀmarkingsꢀtoꢀfacilitateꢀ
installation
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
•ꢀꢀIncludesꢀripcord
22 AWG CONDUCTORS
ꢀ
ꢀ
2
4
22
22
22
22
22
22
22
22
22
Solid
Solid
7/30
7/30
7/30
7/30
7/30
7/30
7/30
0.007
0.007
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.118
0.126
0.122
0.141
0.141
0.164
0.180
0.212
0.219
3.00
3.20
3.10
3.58
3.66
4.17
4.57
5.38
5.56
E1000S
E1001S
E1002S
E1003S
E1004S
E1006S
E1008S
E1010S
E1012S
Applications:
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀWiringꢀofꢀtheꢀfollowingꢀsystems:
2
ꢀ
ꢀ
3
Intercom
Security
Audio
Background music
4
6
8
ꢀ
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
10
12
Compliances:
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL3Rꢀ
(UL:ꢀ75°C,ꢀ150V)
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ
(UL:ꢀ75°C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
ꢀ
20 AWG CONDUCTORS
ꢀ
2
3
4
20
20
20
7/28
7/28
7/28
0.007
0.008
0.008
0.18
0.20
0.20
0.015
0.015
0.015
0.38
0.38
0.38
0.134
0.134
0.142
3.40
3.40
3.60
E1022S
E1023S
E1024S
ꢀ
ꢀ
18 AWG CONDUCTORS
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
2
2
18
18
18
18
18
18
18
18
Solid
7/26
7/26
7/26
7/26
7/26
7/26
7/26
0.008
0.009
0.009
0.009
0.008
0.008
0.008
0.009
0.20
0.23
0.23
0.23
0.20
0.20
0.20
0.23
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.144
0.156
0.166
0.187
0.225
0.245
0.282
0.291
3.66
3.96
4.22
4.75
5.72
6.22
7.16
7.39
E1030S
E1032S
E1033S
E1034S
E1036S
E1038S
E1040S
E1041S
packaging and color options
3
Color Code Chart
4
Nꢂ. ꢂF
Nꢂ. ꢂF
CꢂND.
6
CꢂND.
CꢂꢁꢂR
Black
Red
CꢂꢁꢂR
Orange
Yellow
Violet
Gray
8
1
2
3
4
5
6
7
8
9
10
11
12
10
12
White
Green
Brown
Blue
16 AWG CONDUCTORS
Pink
2
3
4
16 19/.0117 0.009
16 19/.0117 0.009
16 19/.0117 0.009
0.25
0.25
0.25
0.015
0.015
0.015
0.38
0.38
0.38
0.178
0.193
0.210
4.52
4.90
5.33
E1042S
E1043S
E1044S
Tan
14 AWG CONDUCTORS
2
4
14 19/.0147 0.013
14 19/.0147 0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.224
0.264
5.69
6.71
E1052S*
E1054S*
12 AWG CONDUCTORS
2
4
12 19/.0185 0.013
12 19/.0185 0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.260
0.312
6.60
7.92
E1062S*
E1064S*
* NEC CL3R only
134
Sound, Alarm and Security Cable
Electronics
Multi-Conductor, Shielded, Riser
NEC Type CMR and/or CL3R
Product Construction:
Conductor:
ꢀ
•ꢀꢀStrandedꢀorꢀsolidꢀbareꢀcopperꢀperꢀ
ASTM B-3, B-8 and B-286
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
NꢂM. JACkEꢀ
WAꢁꢁ
NꢂMINAꢁ ꢂ.D.
CAꢀAꢁꢂg Nꢂ. ꢂF AWg
CꢂND.
Shield:
NUMBER CꢂND. SIZE SꢀRAND INCHES
mm
INCHES
mm
INCHES
mm
ꢀ
ꢀ
•ꢀOꢀ verallꢀFlexfoil® polyester supported
22 AWG CONDUCTORS
aluminum foil
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwireꢀ
2
2
22
22
22
22
22
22
22
22
Solid
7/30
7/30
7/30
7/30
7/30
7/30
7/30
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.010
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.25
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.117
0.132
0.135
0.147
0.173
0.195
0.218
0.238
2.97
3.35
3.43
3.73
4.39
4.95
5.54
6.05
E2000S
E2002S
E2003S
E2004S
E2006S
E2008S
E2010S
E2012S
Jacket:
•ꢀꢀPremium-grade,ꢀgrayꢀPVC
•ꢀꢀSequentialꢀfootageꢀmarkingsꢀtoꢀfacilitateꢀ
installation
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
•ꢀꢀIncludesꢀripcord
ꢀ
ꢀ
3
4
6
ꢀ
ꢀ
8
Applications:
ꢀ
ꢀ
10
12
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀWiringꢀofꢀtheꢀfollowingꢀsystems:
20 AWG CONDUCTORS
Intercom
Security
Audio
Background music
2
3
4
20
20
20
7/28
7/28
7/28
0.007
0.008
0.007
0.18
0.20
0.18
0.015
0.015
0.015
0.38
0.38
0.38
0.142
0.151
0.171
3.61
3.84
4.34
E2022S
E2023S
E2024S
ꢀ
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Compliances:
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL3Rꢀ
(UL:ꢀ75°C,150V)
18 AWG CONDUCTORS
ꢀ
2
2
18
18
18
18
18
18
18
18
Solid
7/26
7/26
7/26
7/26
7/26
7/26
7/26
0.009
0.009
0.009
0.009
0.008
0.008
0.008
0.008
0.20
0.23
0.23
0.23
0.20
0.20
0.20
0.20
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.147
0.164
0.172
0.187
0.230
0.250
0.287
0.296
3.73
4.17
4.37
4.75
5.54
6.35
7.29
7.52
E2030S
E2032S
E2033S
E2034S
E2036S
E2038S
E2040S
E2041S
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ
(UL:ꢀ75°C,ꢀ300V)
3
ꢀ
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
4
6
Packaging:
8
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
10
12
16 AWG CONDUCTORS
Color Code Chart
2
3
4
16 19/.0117 0.009
16 19/.0117 0.009
16 19/.0117 0.009
0.23
0.23
0.23
0.015
0.015
0.015
0.38
0.38
0.38
0.189
0.198
0.219
4.80
5.03
5.56
E2042S
E2043S
E2044S
Nꢂ. ꢂF
Nꢂ. ꢂF
CꢂND.
CꢂND.
CꢂꢁꢂR
Black
Red
CꢂꢁꢂR
Orange
Yellow
Violet
Gray
1
2
3
4
5
6
7
8
9
10
11
12
14 AWG CONDUCTORS
White
Green
Brown
Blue
2
4
14 19/.0147 0.013
14 19/.0147 0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.245
0.269
6.22
6.83
E2052S*
E2054S*
Pink
Tan
12 AWG CONDUCTORS
2
4
12 19/.0185 0.013
12 19/.0185 0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.281
0.312
7.14
7.92
E2062S*
E2064S*
* NEC CL3R only
135
Electronics
Sound, Alarm and Security Cable
Multi-Conductor, Unshielded, Plenum
NEC Type CMP and/or CL3P
Product Construction:
Conductor:
ꢀ
•ꢀꢀStrandedꢀorꢀsolidꢀbareꢀcopperꢀperꢀ
ASTM B-3, B-8 and B-286
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
PVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
NꢂM. JACkEꢀ
WAꢁꢁ
NꢂMINAꢁ ꢂ.D.
CAꢀAꢁꢂg Nꢂ. ꢂF AWg
CꢂND.
Jacket:
NUMBER CꢂND. SIZE SꢀRAND INCHES
mm
INCHES
mm
INCHES
mm
ꢀ
ꢀ
•ꢀPꢀ remium-gradeꢀnaturalꢀFlexguard® PVC
22 AWG CONDUCTORS
•ꢀꢀSequentialꢀfootageꢀmarkingsꢀtoꢀfacilitateꢀ
installation
•ꢀꢀTemperatureꢀrange:ꢀ0°Cꢀtoꢀ+75°C
•ꢀꢀRipcordꢀavailable—consultꢀCustomerꢀ
2
4
22
22
22
22
22
22
22
22
22
Solid
Solid
7/30
7/30
7/30
7/30
7/30
7/30
7/30
0.007
0.007
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.18
0.18
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.108
0.124
0.120
0.127
0.139
0.164
0.178
0.194
0.211
2.74
3.15
3.05
3.23
3.53
4.17
4.52
4.92
5.36
E3000S
E3001S
E3002S
E3003S
E3004S
E3006S
E3008S
E3010S
E3012S
ꢀ
ꢀ
Service for details
2
3
Applications:
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
•ꢀꢀWiringꢀofꢀtheꢀfollowingꢀsystems:
ꢀ
ꢀ
4
6
Intercom
Security
Audio
Background music
8
10
12
ꢀ
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Compliances:
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL3Pꢀ
(UL:ꢀ75°C,ꢀ150V)
20 AWG CONDUCTORS
ꢀ
2
3
4
20
20
20
7/28
7/28
7/28
0.009
0.009
0.009
0.23
0.23
0.23
0.015
0.015
0.015
0.38
0.38
0.38
0.138
0.146
0.161
3.51
3.71
4.09
E3022S
E3023S
E3024S
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMPꢀ
(UL:ꢀ75°C,ꢀ300V)
ꢀ
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀFlameꢀTest
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
18 AWG CONDUCTORS
2
2
3
4
6
8
18
18
18
18
18
18
Solid
7/26
7/26
7/26
7/26
7/26
0.008
0.008
0.008
0.008
0.008
0.008
0.20
0.20
0.20
0.20
0.20
0.20
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.142
0.156
0.166
0.187
0.216
0.235
3.61
3.96
4.22
4.75
5.49
5.97
E3030S
E3032S
E3033S
E3034S
E3036S
E3038S
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart
Nꢂ. ꢂF
Nꢂ. ꢂF
CꢂND.
CꢂND.
CꢂꢁꢂR
Black
Red
CꢂꢁꢂR
Orange
Yellow
Violet
Gray
16 AWG CONDUCTORS
1
2
3
4
5
6
7
8
9
10
11
12
2
3
4
16 19/.0117 0.008
16 19/.0117 0.008
16 19/.0117 0.009
0.20
0.20
0.23
0.015
0.015
0.015
0.38
0.38
0.38
0.174
0.185
0.205
4.42
4.70
5.21
E3042S
E3043S
E3044S
White
Green
Brown
Blue
14 AWG CONDUCTORS
Pink
2
4
14 19/.0147 0.011
14 19/.0147 0.011
0.28
0.28
0.015
0.015
0.38
0.38
0.216
0.255
5.49
6.48
E3052S*
E3054S*
Tan
12 AWG CONDUCTORS
2
4
12 19/.0185 0.011
12 19/.0185 0.011
0.28
0.28
0.015
0.015
0.38
0.38
0.252
0.298
6.40
7.57
E3062S*
E3064S*
* NEC CL3P only
136
Sound, Alarm and Security Cable
Electronics
Multi-Conductor, Shielded, Plenum
NEC Type CMP and/or CL3P
Product Construction:
Conductor:
ꢀ
•ꢀꢀStrandedꢀorꢀsolidꢀbareꢀcopperꢀper
ASTM B-3, B-8 and B-286
Insulation:
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀFlexguard®
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
NꢂM. JACkEꢀ
WAꢁꢁ
PVC
NꢂMINAꢁ ꢂ.D.
CAꢀAꢁꢂg Nꢂ. ꢂF AWg
CꢂND.
NUMBER CꢂND. SIZE SꢀRAND INCHES
mm
INCHES
mm
INCHES
mm
Shield:
ꢀ
ꢀ
•ꢀOꢀ verallꢀFlexfoil® polyester supported
22 AWG CONDUCTORS
aluminum foil
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwireꢀ
2
2
3
4
6
8
22
22
22
22
22
22
Solid
7/30
7/30
7/30
7/30
7/30
0.007
0.008
0.008
0.008
0.008
0.010
0.18
0.20
0.20
0.20
0.20
0.25
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.116
0.128
0.131
0.147
0.176
0.184
2.95
3.25
3.33
3.73
4.47
4.67
E2100S
E2102S
E2103S
E2104S
E2106S
E2108S
Jacket:
ꢀ
ꢀ
•ꢀPꢀ remium-gradeꢀnaturalꢀFlexguard® PVC
•ꢀꢀSequentialꢀfootageꢀmarkingsꢀtoꢀfacilitateꢀ
installation
•ꢀꢀTemperatureꢀrange:ꢀ0°Cꢀtoꢀ+75°C
•ꢀꢀRipcordꢀavailable—consultꢀCustomerꢀ
ꢀ
ꢀ
Service for details
20 AWG CONDUCTORS
2
3
4
20
20
20
7/28
7/28
7/28
0.009
0.009
0.009
0.23
0.23
0.23
0.015
0.015
0.015
0.38
0.38
0.38
0.143
0.151
0.166
3.63
3.84
4.22
Applications:
E2122S
E2123S
E2124S
ꢀ
•ꢀꢀPower-limitedꢀcontrolꢀcircuits
ꢀ
•ꢀꢀWiringꢀofꢀtheꢀfollowingꢀsystems:
Intercom
Security
Audio
18 AWG CONDUCTORS
2
2
3
4
6
8
18
18
18
18
18
18
Solid
7/26
7/26
7/26
7/26
7/26
0.008
0.008
0.008
0.008
0.010
0.010
0.20
0.20
0.20
0.20
0.25
0.25
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.148
0.164
0.169
0.185
0.230
0.252
3.76
4.17
4.29
4.70
5.84
6.40
E2200S
E2202S
E2203S
E2204S
E2206S
E2208S
Background music
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
ꢀ
Compliances:
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL3Pꢀ
(UL:ꢀ75°C,ꢀ150V)
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMPꢀ
(UL:ꢀ75°C,ꢀ300V)
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀFlameꢀTest
•ꢀꢀCaliforniaꢀStateꢀFireꢀMarshallꢀApproved
16 AWG CONDUCTORS
2
3
4
16 19/.0117 0.008
16 19/.0117 0.008
16 19/.0117 0.008
0.20
0.20
0.20
0.015
0.015
0.015
0.38
0.38
0.38
0.179
0.190
0.209
4.55
4.83
5.31
E2242S
E2243S
E2244S
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
14 AWG CONDUCTORS
2
4
14 19/.0147 0.008
14 19/.0147 0.008
0.20
0.20
0.015
0.015
0.38
0.38
0.207
0.260
5.26
6.60
E2252S*
E2254S*
Color Code Chart
Nꢂ. ꢂF
CꢂND.
CꢂꢁꢂR
Black
Red
12 AWG CONDUCTORS
1
2
3
4
5
6
7
8
2
4
12 19/.0185 0.008
12 19/.0185 0.008
0.20
0.20
0.015
0.015
0.38
0.38
0.244
0.288
6.20
7.32
E2262S*
E2264S*
* NEC CL3P only
White
Green
Brown
Blue
Orange
Yellow
137
Electronics
Sound, Alarm and Security Cable
ꢀelephone Station/Intercom & Speaꢃer/
Burꢄlar Alarm NECꢀTypesꢀCMRꢀorꢀCM/CL2ꢀandꢀCMX-Outdoorꢀ
Product
Construction:
Conductor:
ꢀ
•ꢀSꢀ olidꢀorꢀstrandedꢀbareꢀcopperꢀperꢀ
ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀSꢀ emi-rigid,ꢀflame-retardantꢀPVC
•ꢀCꢀ olorꢀcode:ꢀSeeꢀchartꢀbelow
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
NꢂM. JACkEꢀ
ꢀHICkNESS
NꢂMINAꢁ ꢂ.D.
CAꢀAꢁꢂg
NUMBER
Nꢂ. ꢂF AWg
CꢂND.
Core:
CꢂND. SIZE SꢀRAND INCHES
mm
INCHES
mm
INCHES
mm
ꢀ
•ꢀCꢀ onductorsꢀinꢀaꢀquadꢀconfigurationꢀ(C4412)
INTERCOM, SPEAKER AND BURGLAR ALARM
Jacket:
2
2
3
4
4
22
Solid
0.007
0.18
0.18
0.18
0.18
0.18
0.020
0.020
0.016
0.015
0.015
0.51
0.51
0.41
0.38
0.38
0.115
0.125
0.118
0.125
0.135
2.92
3.18
3.00
3.18
3.43
C4408*
C4408ST*
C4410
C4412*
C4412ST*
ꢀ
ꢀ
ꢀ
•ꢀLꢀ ow-temperature,ꢀflame-retardantꢀbeigeꢀ
PVCꢀ(-20°Cꢀtoꢀ+60°C)
22 7/.0096 0.007
22
22
•ꢀSꢀ equentialꢀfootageꢀmarkingsꢀtoꢀfacilitateꢀ
installation
•ꢀCꢀ ablesꢀareꢀsuitableꢀforꢀinstallationꢀwithꢀ
T-18 staples
Solid
Solid
0.007
0.007
22 7/.0096 0.007
Color Code Chart
Applications:
ꢀ
•ꢀIꢀntercomꢀsystemsꢀandꢀspeakerꢀextensionꢀ
service
Nꢂ. ꢂF
PAIRS
Nꢂ. ꢂF
PAIRS
3
4
CꢂꢁꢂR
CꢂꢁꢂR
Yellow
Black
ꢀ
ꢀ
•ꢀSꢀ uggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
•ꢀCꢀ 4413 only: Product is in conformance
with TIA 568C, TIA 570B standards and
theꢀFCCꢀPartꢀ68ꢀrulingꢀwhichꢀrequiresꢀ
telephone system cables for voice and
data services into homes to be at minimum
category 3, 2 pr. 22 AWG solid.
Red
Green
1
2
TELEPHONE STATION
CATEGORY 3
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
NꢂM. JACkEꢀ
ꢀHICkNESS
NꢂMINAꢁ ꢂ.D.
Compliances:
CAꢀAꢁꢂg Nꢂ. ꢂF AWg
NUMBER PAIRS SIZE SꢀRAND INCHES
CꢂND.
ꢀ
ꢀ
ꢀ
•ꢀNꢀ ECꢀArticleꢀ800ꢀTypeꢀCMR/CMX-Indoor/
Outdoor;ꢀULꢀListedꢀ(60°C,ꢀ300V)
•ꢀCꢀ oilꢀPacksꢀ(500')ꢀ–ꢀNECꢀArticleꢀ800ꢀType
CM/CMX-Indoor/Outdoor;ꢀETLꢀListed
•ꢀCꢀ oilꢀPacksꢀ(500')ꢀ–ꢀNECꢀArticleꢀ725ꢀType
CL2; ETL Listed
mm
INCHES
mm
INCHES
mm
0.145 x
0.095
3.68 x
2.41
2
24
Solid
0.007
0.18
0.015
0.38
C4413
Note: Outdoor rating allows cable
to be exposed for short distances
from the network interface device
on the outside of the house to the
point where the cable enters the
house. This type of cable is not to
be buried or direct buried.
Color Code Chart (Bandmarked)
Nꢂ. ꢂF
PAIRS
ꢀ
ꢀ
•ꢀCꢀ 4413ꢀonly,ꢀCategoryꢀ3
Nꢂ. ꢂF
PAIRS
•ꢀRꢀ oHSꢀCompliantꢀDirectiveꢀ2002/95/EC
CꢂꢁꢂR
CꢂꢁꢂR
Packaging:
White-Blue Band
Blue
White-Orange Band
Orange
1
2
ꢀ
•ꢀPꢀ leaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Product Construction:
Conductor:
ꢀ
•ꢀ2ꢀ 2ꢀthruꢀ18ꢀAWGꢀoneꢀtinned/oneꢀbareꢀfullyꢀ
annealed stranded copper
•ꢀSꢀ trandedꢀbareꢀcopperꢀperꢀASTMꢀB-3ꢀorꢀ
stranded tinned copper per ASTM B-33
ꢀ
Insulation:
ꢀ
ꢀ
ꢀ
•ꢀPꢀ remium-grade,ꢀcolor-codedꢀPVC
•ꢀTꢀ emperatureꢀrange:ꢀ-20°Cꢀtoꢀ+60°C
•ꢀCꢀ olorꢀcode:ꢀSeeꢀchartꢀbelow
BURGLAR ALARM
NꢂM.*
C-C
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
Applications:
NꢂMINAꢁ ꢂ.D.
CAꢀAꢁꢂg Nꢂ. ꢂF AWg
CꢂND.
CAP.
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀBꢀ urglarꢀalarms
NUMBER CꢂND. SIZE SꢀRAND
INCHES
mm
INCHES
mm
pF/ft
•ꢀIꢀntercomꢀsystems
•ꢀRꢀ emoteꢀcontrolꢀcircuits
•ꢀSꢀ uggestedꢀvoltageꢀrating:ꢀ150ꢀvolts
2
2
2
3
22
20
18
18
7/30
7/28
7/0.015
7/0.015
0.024
0.024
0.024
0.024
0.61
0.61
0.61
0.61
0.156
0.172
0.192
0.202
3.96
4.37
4.88
5.13
20.0
22.5
24.5
28.5
C6310
C6311
C6312
C6313
Features:
ꢀ
•ꢀPꢀ olarityꢀridgeꢀforꢀeasyꢀidentification
Compliances:
*Capacitance between conductors
ꢀ
ꢀ
ꢀ
•ꢀNꢀ ECꢀArticleꢀ725ꢀTypeꢀCL2ꢀ(UL:ꢀ60°C,ꢀ150V)
•ꢀRꢀ oHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀDꢀ esignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀVerticalꢀ
TrayꢀFlameꢀTest
Color Code Chart
ꢂRDERINg
SUFFIX
ꢂRDERINg
SꢀꢂCk CꢂꢁꢂRS
SꢀꢂCk CꢂꢁꢂRS
SUFFIX
Packaging:
1. White-White
2. Brown-Brown
02
08
3. Black-White
96
ꢀ
•ꢀPꢀ leaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
138
Sound, Alarm and Security Cable
Electronics
Antenna Rotor
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
bare copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
NꢂM. JACkEꢀ
ꢀHICkNESS
NꢂMINAꢁ ꢂ.D.
•ꢀꢀColorꢀcode:ꢀSeeꢀchartsꢀbelow
CAꢀAꢁꢂg
NUMBER
Nꢂ. ꢂF AWg
CꢂND.
CꢂND.
SIZE SꢀRAND INCHES
mm
INCHES
mm
INCHES
mm
Jacket:
•ꢀPꢀ ermaline® polyethylene, black
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+60°C
C5076
C5086
C5096
C5078
C5460†
C5084
4
5
8
4
2
4
22
22
22
20
18
18
7/30
7/30
0.010
0.010
0.010
0.009
0.016
0.016
0.25
0.25
0.25
0.23
0.25
0.40
0.022
0.022
0.020
0.023
0.020
0.030
0.56
0.56
0.51
0.58
0.51
0.76
0.165
0.175
0.205
0.180
0.208
0.245
4.19
4.45
5.21
4.57
5.28
6.22
ꢀ
ꢀ
7/30
Applications:
10/30
16/30
16/30
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀRotorꢀantennaꢀcontrols
•ꢀꢀOutdoorꢀinstallations
•ꢀꢀDirectꢀburial
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ200ꢀvolts
†Color Code Black/Red
Features:
ꢀ
ꢀ
ꢀ
•ꢀPꢀ ermaline® jackets resist deterioration
•ꢀꢀSunlight-resistant
•ꢀꢀMoisture-ꢀandꢀsalt-resistant
Compliances:
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀthruꢀ16ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
bare copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcolor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
NꢂM. JACkEꢀ
ꢀHICkNESS
NꢂMINAꢁ ꢂ.D.
CAꢀAꢁꢂg
NUMBER
Nꢂ. ꢂF AWg
CꢂND.
Jacket:
•ꢀꢀPVC,ꢀchromeꢀgrayꢀorꢀblackꢀ
CꢂND.
SIZE SꢀRAND INCHES
mm
INCHES
mm
INCHES
mm
ꢀ
ꢀ
(C4080, C4090)
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
4
5
8
4
5
4
22
22
22
20
20
18
7/30
7/30
0.010
0.010
0.010
0.010
0.010
0.016
0.25
0.25
0.25
0.25
0.25
0.40
0.020
0.020
0.020
0.020
0.020
0.030
0.51
0.51
0.51
0.51
0.51
0.76
0.161
0.175
0.205
0.180
0.197
0.255
4.09
4.45
5.21
4.57
5.00
6.48
C1118
C1124
C1130
C1119
C1126
C1123
7/30
Applications:
ꢀ
•ꢀꢀCompatibleꢀwithꢀAllianceꢀHam/CBꢀandꢀ
TV rotors
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ200ꢀvolts
10/30
10/30
16/30
ꢀ
Compliances:
ꢀ
COMBINATION ROTOR CABLE
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
6-22
2-18
6-20
2-16
7/30
16/30
10/30
26/30
0.012
0.016
0.010
0.016
0.30
0.41
0.25
0.41
8
8
0.030
0.030
0.76
0.76
0.260
0.280
6.60
7.11
C4080
C4090
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Antenna Rotor Cable
Color Code Chart
Combination Rotor Cable
Color Code Chart
Nꢂ. ꢂF
Nꢂ. ꢂF
CꢂND.
CꢂꢁꢂR
Black
White
Red
Green
Yellow
Blue
CꢂND.
CꢂꢁꢂR
1
2
3
4
5
6
7
8
16/18 ga.
Black
Red
1
2
20/22 ga.
White
Green
Yellow
Blue
Brown
Orange
1
2
3
4
5
6
Brown
Orange
139
Electronics
Sound, Alarm and Security Cable
ꢁow-Voltaꢄe Sprinꢃler Wire
60ºC 30 Volts UL
APPRꢂX.
WEIgHꢀ
PER
ꢁENgꢀH
Pkg
CARꢀꢂN
DIMENSIꢂNS
(H x W x D)
PꢂWER RAꢀINg(1)
VꢂꢁꢀS AMPS WAꢀꢀS
CAꢀAꢁꢂg
NUMBER
Nꢂ. ꢂF AWg ꢂF CꢂRD PACkAgE
PER CꢀN (ꢁBS)
(S)
CꢂND. SIZE
(FEEꢀ)
ꢀYPE
CꢀN.
UPC NUMBER
LOW VOLTAGE SPRINKLER WIRE - 30 VOLTS - UL
4
4
18
18
18
18
18
18
18
18
18
100
500
50
Cuff
Spool
Cuff
30
30
30
30
30
30
30
30
30
15
15
15
15
15
15
15
15
15
450
450
450
450
450
450
450
450
450
6
1
6
6
1
6
6
1
1
22
18
13
27
22
18
36
31
44
8.5 x 12.25 x 14
079407238248
23824-60-01
23804-18-01
23815-60-01
23825-60-01
23805-18-01
23817-60-01
23827-60-01
23807-18-01
23810-18-01
10.625 x 10.625 x 6.313 079407908047
5
8.5 x 12.25 x 14
9.5 x 14 x 17
079407238156
079407238255
5
100
500
50
Cuff
5
Spool
Cuff
10.625 x 10.625 x 6.313 079407908054
7
8.5 x 12.25 x 14
9.5 x 14 x 17
079407238170
079407238279
7
100
500
500
Cuff
7
Spool
Reel
10.625 x 10.625 x 6.313 079407908078
10
—
079407908108
(1)ꢀAmpsꢀandꢀwattsꢀareꢀofferedꢀONLYꢀasꢀaꢀguideꢀtoꢀtheꢀendꢀuser.
(s) Actual shipping weight may vary.
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀAWGꢀfullyꢀannealedꢀsolidꢀbareꢀcopperꢀ
Color Code Chart
per ASTM B-3
Nꢂ. ꢂF
Insulation:
CꢂNDUCꢀꢂRS
CꢂꢁꢂR
Black
White
Red
Green
Orange
Yellow
Blue
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcolor-codedꢀPVC
•ꢀꢀPremium-gradeꢀPEꢀjacket,ꢀblack
•ꢀꢀNylonꢀripꢀcordꢀtoꢀfacilitateꢀjacketꢀremoval
•ꢀꢀTemperatureꢀrange:ꢀ-20ºCꢀtoꢀ+60ºC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀatꢀright
1
2
3
4
5
6
7
8
9
Jacket Marking:
•ꢀꢀCAROLꢀ(SIZE)ꢀ30VꢀSPRINKLERꢀ
SYSTEMSꢀWIREꢀ-ꢀDIRECTꢀBURIALꢀ
E54567 (UL)
ꢀ
Brown
Gray
Purple
Applications:
•ꢀꢀLow-voltageꢀgolfꢀcourseꢀsatellite
sprinkler control
ꢀ
10
ꢀ
•ꢀꢀResidentialꢀsprinklerꢀsolenoidꢀcontrol
Compliances:
ꢀ
•ꢀꢀULꢀListedꢀunderꢀaꢀULꢀMiscellaneousꢀ
Wire file
ꢀ
ꢀ
•ꢀꢀULꢀListedꢀforꢀoutdoorsꢀapplications
•ꢀꢀULꢀListedꢀforꢀdirectꢀburialꢀapplications
Packaging:
ꢀ
ꢀ
•ꢀꢀSeeꢀtabularꢀdataꢀabove
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
140
Sound, Alarm and Security Cable
Electronics
ꢀhermostat Wire
60ºC 30 Volt CSA Type LVT
Product Construction:
Conductors:
ꢀ
•ꢀꢀ8ꢀAWGꢀannealedꢀsolidꢀbareꢀcopperꢀperꢀ
ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcolor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
APPRꢂX.
Jacket:
NꢂMINAꢁ ꢂ.D.
INCHES mm
NEꢀ WEIgHꢀ
CAꢀAꢁꢂg Nꢂ. ꢂF AWg
NUMBER CꢂND. SIZE
CꢂND.
SꢀD.
CꢀN.
ꢁBS/m (S)
ꢀ
ꢀ
•ꢀꢀPolyvinylchlorideꢀ(PVC),ꢀbrown
SꢀRAND INCHES
mm
•ꢀꢀTemperatureꢀrange:ꢀ-20ºCꢀtoꢀ+60ºC
18 AWG THERMOSTAT WIRE – 30 VOLT – CSA TYPE LVT
Jacket Marking:
2
3
18
18
18
18
18
18
18
18
18
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.017
0.017
0.017
0.017
0.017
0.017
0.017
0.017
0.017
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.210
0.222
0.242
0.262
0.280
0.285
0.304
0.328
0.360
5.33
5.64
6.15
6.65
7.11
7.24
7.75
8.33
9.14
25
33
41
50
60
65
74
83
92
2000'
500'
05092
05093*
05094
05095
05096*
05097*
05098*
05099*
05091*
ꢀ
•ꢀꢀCAROLꢀ(SIZE)ꢀCSAꢀLL#ꢀTYPEꢀLVTꢀFT-4
Applications:
•ꢀꢀThermostatꢀcontrol
•ꢀꢀHeatingꢀandꢀairꢀconditioningꢀinstallations
•ꢀꢀTouch-plateꢀsystems
•ꢀꢀBurglarꢀalarms
•ꢀꢀIntercomꢀsystems
•ꢀꢀDoorꢀbells
•ꢀꢀAnnunciatorꢀandꢀbellꢀsystems
•ꢀꢀRemoteꢀcontrolꢀunits
•ꢀꢀSignalꢀsystems
4
1000'
1000'
1000'
1000'
1000'
1000'
250'
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
5
6
7
8
9
10
•ꢀꢀOtherꢀlow-voltageꢀinstallations
*Non-stock item; minimum quantity purchase required.
(S) Actual shippng weight may vary.
Compliances:
•ꢀꢀCSAꢀTypeꢀLVT
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
ꢀ
ꢀ
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Color Code Chart
APPRꢂXIMAꢀE VꢂꢁꢀAgE DRꢂP/AMP Aꢀ 68ºF
Nꢂ. ꢂF
CꢂNDUCꢀꢂRS
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
.5
CꢂꢁꢂRS
White, Red
White, Red, Green
2
3
White, Red, Green, Blue
4
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown,ꢀOrange
5
6
7
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown,ꢀOrange,ꢀBlack
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown,ꢀOrange,ꢀBlack,ꢀPurple
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown,ꢀOrange,ꢀBlack,ꢀPurple,ꢀGray
8
9
10
LENGTH OF RUN (FEET)
0
0
50
100 150 200 250 300 350 400 450 500
VOLTAGE DROP PER (1) AMP
BASED ON 115 VOLTS
141
Electronics
Sound, Alarm and Security Cable
ꢀhermostat Wire
105ºC 150 Volt UL Type CL2
Product Construction:
Conductors:
ꢀ
•ꢀꢀ20ꢀandꢀ18ꢀAWGꢀannealedꢀsolidꢀbareꢀ
copper per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
SꢀRAND INCHES mm
APPRꢂX.
NEꢀ WEIgHꢀ
ꢁBS/m(S)
Jacket:
NꢂMINAꢁ ꢂ.D.
INCHES mm
CAꢀAꢁꢂg Nꢂ. ꢂF AWg
NUMBER CꢂND. SIZE
CꢂND.
SꢀD.
CꢀN.
ꢀ
ꢀ
•ꢀꢀPolyvinylchlorideꢀ(PVC),ꢀwhite
•ꢀꢀTemperatureꢀrange:ꢀ-20ºCꢀtoꢀ+105ºC
20 AWG THERMOSTAT WIRE – 150 VOLT – UL TYPE CL2
Jacket Marking:
•ꢀꢀCAROLꢀAWGꢀTYPEꢀCL2ꢀE#ꢀ(UL)ꢀ
105ºCꢀSUNLIGHTꢀRESISTANTꢀ-ꢀMADEꢀ
IN USA
05482
05483
05484
05485
05486
05487
05488
05489
05481
2
3
20
20
20
20
20
20
20
20
20
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.008 0.203 0.128
0.008 0.203 0.135
0.008 0.203 0.144
0.008 0.203 0.158
0.008 0.203 0.177
0.008 0.203 0.175
0.008 0.203 0.186
0.008 0.203 0.210
0.008 0.203 0.235
3.25
3.43
3.66
4.01
4.46
4.45
4.72
5.33
5.97
11
16
19
24
27
31
35
40
45
1000'
1000'
500'
500'
500'
500'
500'
500'
250'
ꢀ
4
Applications:
•ꢀꢀThermostatꢀcontrol
•ꢀꢀHeatingꢀandꢀairꢀconditioningꢀ
installations
•ꢀꢀTouch-plateꢀsystems
•ꢀꢀBurglarꢀalarms
•ꢀꢀIntercomꢀsystems
5
ꢀ
ꢀ
6
7
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
8
9
•ꢀꢀDoorꢀbells
10
•ꢀꢀAnnunciatorꢀandꢀbellꢀsystems
•ꢀꢀRemoteꢀcontrolꢀunits
•ꢀꢀSignalꢀsystems
18 AWG THERMOSTAT WIRE – 150 VOLT – UL TYPE CL2
05582
05583
05584
05585
05586
05587
05588
05589
05581
2
3
18
18
18
18
18
18
18
18
18
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.009 0.203 0.155
0.009 0.203 0.164
0.009 0.203 0.180
0.009 0.203 0.200
0.009 0.203 0.215
0.009 0.203 0.215
0.009 0.203 0.235
0.008 0.203 0.245
0.008 0.203 0.300
3.94
4.17
4.57
5.08
5.46
5.46
5.97
6.22
7.62
16
22
28
36
42
48
54
61
69
1000'
1000'
500'
500'
500'
500'
500'
500'
250'
•ꢀꢀOtherꢀlow-voltageꢀinstallations
Industry Approvals:
•ꢀꢀULꢀListedꢀTypeꢀCL2
4
ꢀ
5
Compliances:
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
6
ꢀ
Packaging:
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
7
ꢀ
8
packaging and color options
9
10
(S) Actual shipping weight may vary.
Color Code Chart
APPRꢂXIMAꢀE VꢂꢁꢀAgE DRꢂP/AMP Aꢀ 68ºF
Nꢂ. ꢂF
CꢂNDUCꢀꢂRS
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
.5
CꢂꢁꢂR
White, Red
2
3
White, Red, Green
White, Red, Green, Blue
4
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow
5
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown
6
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown,ꢀOrange
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown,ꢀOrange,ꢀBlack
7
8
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown,ꢀOrange,ꢀBlack,ꢀPurple
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown,ꢀOrange,ꢀBlack,ꢀPurple,ꢀGray
9
10
LENGTH OF RUN (FEET)
0
0
50
100 150 200 250 300 350 400 450 500
VOLTAGE DROP PER (1) AMP
BASED ON 115 VOLTS
142
Sound, Alarm and Security Cable
Electronics
ꢀhermostat Wire, Unjacꢃeted
60ºC Low Voltage and Intercom Cable
Product Construction:
Conductors:
ꢀ
•ꢀꢀ20ꢀAWGꢀannealedꢀsolidꢀbareꢀcopperꢀperꢀ
ASTM B-3
Insulation:
ꢀ
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀTemperatureꢀrange:ꢀ-20ºCꢀtoꢀ+60ºC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NꢂM. INSUꢁAꢀIꢂN
ꢀHICkNESS
APPRꢂX.
NꢂMINAꢁ ꢂ.D.
INCHES mm
CAꢀAꢁꢂg Nꢂ. ꢂF AWg
NUMBER CꢂND. SIZE
CꢂND.
NEꢀ WEIgHꢀ
SꢀD.
CꢀN.
Jacket:
•ꢀꢀThisꢀproductꢀisꢀunjacketed
SꢀRAND INCHES
mm
ꢁBS/m(S)
ꢀ
20 AWG – TWISTED CONDUCTORS – NO JACKET
Applications:
05782
05783
05784*
05785*
05786*
05788*
2
3
4
5
6
8
20
20
20
20
20
20
Solid
Solid
Solid
Solid
Solid
Solid
0.008 0.203 0.098
0.008 0.203 0.106
0.008 0.203 0.119
0.008 0.203 0.133
0.008 0.203 0.147
0.008 0.203 0.162
2.49
2.69
3.01
3.38
3.73
4.11
7.5
11.0
15.0
18.5
22.0
30.0
4000'
2000'
2000'
1000'
1000'
1000'
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀThermostatꢀcontrol
•ꢀꢀHeatingꢀandꢀairꢀconditioningꢀinstallations
•ꢀꢀTouch-plateꢀsystems
•ꢀꢀBurglarꢀalarms
•ꢀꢀIntercomꢀsystems
•ꢀꢀDoorꢀbells
•ꢀꢀAnnunciatorꢀandꢀbellꢀsystems
•ꢀꢀRemoteꢀcontrolꢀunits
•ꢀꢀSignalꢀsystems
*Non-stock item; minimum quantity purchase required.
(S) Actual shippng weight may vary.
•ꢀꢀOtherꢀlow-voltageꢀinstallations
Packaging:
Color Code Chart
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
Nꢂ. ꢂF
CꢂNDUCꢀꢂRS
packaging and color options
CꢂꢁꢂR
White, Red
2
3
4
5
6
8
White, Red, Green
White, Red, Green, Blue
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown
White,ꢀRed,ꢀGreen,ꢀBlue,ꢀYellow,ꢀBrown,ꢀOrange,ꢀBlack
143
Electronics
Sound, Alarm and Security Cable
Carol® Helix/Hi-ꢀemp® Cateꢄory 6 Cable
Standard-Compliant Solution
Product Construction:
Conductors:
ꢀ
•ꢀꢀ23 AWG solid bare annealed copper
Separator
ꢀ •ꢀTꢀ ape
Insulation
ꢀ •ꢀNꢀ on-Plenum:ꢀPolyolefin
ꢀ •ꢀPꢀ lenum:ꢀFluoropolymer
PART NUMBERS
PUꢁꢁ-PAC® II
SPꢂꢂꢁ-PAC®
CMR
(NꢂN-PꢁENUM)
CMP
(PꢁENUM)
CMR
(NꢂN-PꢁENUM)
CMP
(PꢁENUM)
Rip Cord
ꢀ •ꢀAꢀ pplied longitudinally under jacket
JACkEꢀ CꢂꢁꢂR
Blue
White
Gray
Green
Yellow
Red
CR6.30.07
CR6.30.02
CR6.30.10
CR6.30.06
CR6.30.05
CR6.30.03
CP6.30.07
CP6.30.02
CP6.30.10
CP6.30.06
CP6.30.05
CP6.30.03
CR6.A3.07
CR6.A3.02
CR6.A3.10
CR6.A3.06
CR6.A3.05
CR6.A3.03
CP6.A3.07
CP6.A3.02
CP6.A3.10
CP6.A3.06
CP6.A3.05
CP6.A3.03
Jacket
ꢀ •ꢀNꢀ on-Plenum:ꢀflame-retardantꢀPVC
ꢀ •ꢀPꢀ lenum:ꢀlow-smoke,ꢀflame-retardantꢀ
PVC
ꢀ •ꢀꢀTRU-Mark® print legend contains
footage markings from 1000' to 0'
Applications:
ELECTRICAL PERFORMANCE
ꢀ •ꢀIꢀEEEꢀ802.3:ꢀ1000ꢀBASE-Tꢀ(Gigabitꢀ
Ethernet),ꢀ100ꢀBASE-TX,ꢀ10ꢀBASE-T
ꢀ •ꢀAꢀ NSI/TIA/EIAꢀ854:ꢀ1000ꢀBASE-TX
ꢀ •ꢀ1ꢀ 55 Mp/s, 1.2 Gb/s ATM
ꢀ •ꢀAꢀ NSIꢀX3.263:ꢀ100ꢀMb/s
ꢀ •ꢀIꢀEEEꢀ802.3afꢀDTEꢀPowerꢀ(PoE)
ꢀ •ꢀDꢀ igitalꢀvideo
FREQUENCY PSACR ACR AꢀꢀENUAꢀIꢂN PSNEXꢀ NEXꢀ PSEꢁFEXꢀ EꢁFEXꢀ REꢀURN ꢁꢂSS ꢁCꢁ EꢁꢀCꢀꢁ
MHZ
(MIN) (MIN)
70.3 72.3
59.3 61.5
51.3 53.3
46.7 48.7
44.3 46.3
39.2 41.2
29.9 32.0
22.5 24.5
14.9 16.9
8.8 10.8
(MAX)
2.0
3.8
6.0
7.6
(MIN)
(MIN)
(MIN)
64.8
52.8
44.8
40.7
38.8
34.9
28.9
24.8
21.3
18.8
16.8
13.9
12.8
10.8
(MIN)
67.8
55.7
47.8
43.7
41.7
37.9
31.8
27.8
24.3
21.8
19.8
16.9
15.8
13.8
(MIN)
20.0
23.0
25.0
25.0
25.0
23.6
21.5
20.1
18.9
18.0
17.3
16.3
15.9
15.2
(MIN) (MIN)
40.0 35.0
40.0 23.0
40.0 15.0
38.0 10.9
72.3 74.3
63.3 65.3
57.3 59.3
54.2 56.2
52.8 54.8
49.9 51.9
45.4 47.4
42.3 44.3
39.7 41.7
37.8 39.8
36.3 38.3
34.1 36.1
33.3 35.3
31.8 33.8
1
4
10
16
Compliances:
8.5
37.0
35.1
32.0
30.0
28.2
27.0
26.0
—
9.0
5.1
5.0
5.0
5.0
5.0
5.0
—
20
ꢀ •ꢀAꢀ NSI/TIA/EIAꢀ568ꢀB.2-1ꢀ(Categoryꢀ6)
ꢀ •ꢀAꢀ NSI/TIA/EIAꢀ862ꢀ(Buildingꢀ
Automation)
10.7
15.4
19.8
24.7
29.0
32.8
39.8
43.0
48.9
31.25
62.5
100
150
200
250
350
400
500
ꢀ •ꢀIꢀSO/IECꢀ11801ꢀEd.ꢀ2.0ꢀ(ClassꢀE)
ꢀ •ꢀIꢀCEAꢀS-102-700ꢀ(Categoryꢀ6)
ꢀ •ꢀUꢀ Lꢀ&ꢀc(UL)ꢀTypeꢀCMPꢀ(NFPAꢀ262ꢀandꢀ
CSAꢀFT-6ꢀSteinerꢀTunnelꢀFireꢀTestsꢀforꢀ
Plenum Applications)
3.5
—
—
5.5
—
—
ꢀ •ꢀUꢀ Lꢀ444ꢀ
ꢀ •ꢀRꢀ oHSꢀCompliantꢀDirectiveꢀ2002/95/EC
ꢀ •ꢀTꢀ hird-partyꢀverifiedꢀforꢀguaranteedꢀ
performance
—
—
—
—
—
—
Notes:ꢀValuesꢀareꢀexpressedꢀinꢀdBꢀperꢀ100mꢀ(328ꢀft.)ꢀlength.ꢀValuesꢀaboveꢀ250ꢀMHzꢀareꢀforꢀinformationalꢀpurposesꢀonly.
Packaging:
PHYSICAL DATA
ꢀ
ꢀ
•ꢀ1ꢀ 000' Pull-Pac® Il
•ꢀꢀ1000' Spool-Pac®
CMR (NꢂN-PꢁENUM)
CMP (PꢁENUM)
NominalꢀCableꢀDiameterꢀ(in)ꢀ
Nominal Cable Weight (lbs/1000ft)
Minimum Bend Radius (in)
MaximumꢀPullingꢀForceꢀ(lbs)
TemperatureꢀRatingꢀ(˚C)
ꢀ Installation:
0.205
28
1.0
0.200
28
1.0
32
CATEGORY 6 CROSS-SECTION
JACKET
32
TAPE
INSULATION
CONDUCTOR
RIP CORD
0ꢀtoꢀ+60
-20ꢀtoꢀ+75
0ꢀtoꢀ+60
-20ꢀtoꢀ+75
ꢀ Operation:
ELECTRICAL CHARACTERISTICS
DC Resistanceꢀ(max)ꢀOhms/100mꢀ(328ft)ꢀ@ꢀ20˚C
DC Resistance Unbalance (max) Individual Pair %
Delay Skew (max) ns/100m
9.38
4.0
45
Nom. Velocity of Propagation
% Speed of Light
Characteristic Impedance
Frequencyꢀ(f):ꢀ
Input Impedance
Frequencyꢀ(f):ꢀ
CMP:ꢀ70
CMR:ꢀ68
Ohms
100 15
Ohms
1-250ꢀMHz
1-100ꢀMHz
100-250 MHz
100 15
100 22
Dataꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
144
Sound, Alarm and Security Cable
Electronics
Carol® Helix/Hi-ꢀemp® Cateꢄory 5e Cable
Enhanced Transmission Throughput
Product Construction:
Conductors:
ꢀ
•ꢀꢀ24 AWG solid bare annealed copper
Insulation
ꢀ •ꢀꢀNon-Plenum:ꢀPolyolefin
ꢀ •ꢀꢀPlenum:ꢀFluoropolymer
PART NUMBERS
PUꢁꢁ-PAC® II
Rip Cord
ꢀ •ꢀꢀApplied longitudinally under jacket
SPꢂꢂꢁ-PAC®
Jacket
CMR
CMP
CMR
CMP
JACkEꢀ CꢂꢁꢂR
(NꢂN-PꢁENUM)
(PꢁENUM)
(NꢂN-PꢁENUM)
(PꢁENUM)
ꢀ •ꢀꢀNon-Plenum:ꢀflame-retardantꢀPVC
ꢀ •ꢀꢀPlenum:ꢀlow-smoke,ꢀflame-retardantꢀ
PVC
Blue
White
Gray
Green
Yellow
Red
CR5.30.07
CR5.30.02
CR5.30.10
CR5.30.06
CR5.30.05
CR5.30.03
CP5.30.07
CP5.30.02
CP5.30.10
CP5.30.06
CP5.30.05
CP5.30.03
CR5.A3.07
CR5.A3.02
CR5.A3.10
CR5.A3.06
CR5.A3.05
CR5.A3.03
CP5.A3.07
CP5.A3.02
CP5.A3.10
CP5.A3.06
CP5.A3.05
CP5.A3.03
ꢀ •ꢀꢀTRU-Mark® print legend contains
footage markings from 1000' to 0'
Applications:
ꢀ •ꢀꢀIEEEꢀ802.3:ꢀ1000ꢀBASE-Tꢀ(Gigabitꢀ
Ethernet),ꢀ100ꢀBASE-TX,ꢀ10ꢀBASE-T
ꢀ •ꢀꢀ52/155 Mp/s ATM
ꢀ •ꢀꢀANSIꢀX3.263:ꢀ100ꢀMb/s
ꢀ •ꢀꢀ4/16 Mp/s token ring
ELECTRICAL PERFORMANCE
FREQUENCY PSACR
ACR AꢀꢀENUAꢀIꢂN
PSNEXꢀ
(MIN)
NEXꢀ
(MIN)
PSEꢁFEXꢀ
(MIN)
EꢁFEXꢀ
REꢀURN ꢁꢂSS
(MIN)
MHZ
(MIN)
(MIN)
(MAX)
2.0
4.1
6.5
8.2
(MIN)
63.8
51.7
43.8
39.7
37.7
35.8
33.9
27.8
23.8
19.9
17.7
15.8
12.9
Compliances:
60.3 63.3
49.2 52.2
40.8 43.8
36.0 39.0
33.5 36.5
30.9 33.9
28.2 31.2
18.4 21.4
10.3 13.3
62.3
53.3
47.3
44.2
42.8
41.3
39.9
35.4
32.3
29.4
27.8
26.3
24.1
65.3
56.3
50.3
47.2
45.8
44.3
42.9
38.4
35.3
32.4
30.8
29.3
27.1
60.8
48.7
40.8
36.7
34.7
32.8
30.9
24.8
20.8
16.9
14.7
12.8
9.9
20.0
23.0
25.0
25.0
25.0
24.3
23.6
21.5
20.1
—
1
4
10
16
20
25
31.25
62.5
100
155
200
250
350
ꢀ •ꢀꢀANSI/TIA/EIAꢀ568ꢀB.2ꢀ(Categoryꢀ5e)
ꢀ •ꢀꢀICEAꢀS-90-661ꢀ(Categoryꢀ5e)
ꢀ •ꢀꢀULꢀ&ꢀc(UL)ꢀTypeꢀCMRꢀ(ULꢀ1666)ꢀforꢀ
Non-Plenum
ꢀ •ꢀꢀULꢀ&ꢀc(UL)ꢀTypeꢀCMPꢀ(NFPAꢀ262ꢀandꢀ
CSAꢀFT-6ꢀSteinerꢀTunnelꢀFireꢀTestsꢀforꢀ
Plenum Applications)
9.3
10.4
11.7
17.0
22.0
28.1
32.4
36.9
44.9
ꢀ •ꢀꢀULꢀ444ꢀ
ꢀ •ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
ꢀ •ꢀꢀThird-partyꢀverifiedꢀforꢀguaranteedꢀ
performance
1.4
—
—
4.4
—
—
Packaging:
—
—
—
ꢀ
ꢀ
•ꢀ1ꢀ 000' Pull-Pac® Il
•ꢀꢀ1000' Spool-Pac®
—
—
Notes:ꢀValuesꢀareꢀexpressedꢀinꢀdBꢀperꢀ100mꢀ(328ꢀft.)ꢀlength.ꢀValuesꢀaboveꢀ250ꢀMHzꢀareꢀforꢀinformationalꢀpurposesꢀonly.
PHYSICAL DATA
CMR (NꢂN-PꢁENUM)
CMP (PꢁENUM)
NominalꢀCableꢀDiameterꢀ(in)ꢀ
Nominal Cable Weight (lbs/1000ft)
Minimum Bend Radius (in)
MaximumꢀPullingꢀForceꢀ(lbs)
TemperatureꢀRatingꢀ(˚C)
ꢀ Installation:
0.200
21
0.180
19
CATEGORY 5e CROSS-SECTION
1.0
25
1.0
25
JACKET
0ꢀtoꢀ+60
0ꢀtoꢀ+60
INSULATION
CONDUCTOR
RIP CORD
ꢀ Operation:
-10ꢀtoꢀ+60
-10ꢀtoꢀ+60
ELECTRICAL CHARACTERISTICS
DC Resistanceꢀ(max)ꢀOhms/100mꢀ(328ft)ꢀ@ꢀ20˚C
DC Resistance Unbalance (max) Individual Pair %
Mutual Capacitanceꢀ(nom)ꢀpF/ftꢀ@ꢀ1ꢀKHz
Delay Skew (max) ns/100m
8.9
3.0
14
45
Nom. Velocity of Propagation
% Speed of Light
CMP:ꢀ72
CMR:ꢀ70
Characteristic Impedance
Frequencyꢀ(f):ꢀ
Ohms
100 15
1-100ꢀMHz
Dataꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
145
Electronics
Audio/Video & Home Entertainment Cable
8
Index
Page
Command® Series
Home Entertainment
Cables Guide
147-148
149-150
Command® Series
Cruise Ship Cables Guide
General Cable offers a variety
of Carol® Brand wire and cable
for audio/video and direct
burial applications. From field
production cable to microphone, where they are unavoidable. In
These technically sophisticated
cables are required to contain
sources of interference and
to protect against difficulties
Command® Series
Speaker Cable
151-155
156
Speaker Wire
snake, guitar and speaker
cable, General Cable supports
the increasingly demanding
entertainment industry.
addition to providing the needed
electrical characteristics, the
cables are properly designed to
handle demanding conditions,
such as microphone hum,
handling noise, crosstalk,
electrostatic hum, SCR noise
and common ground noise—
either on stage, in a studio or at
a remote venue.
Superflex® Speaker Wire
Pro Audio Speaker Wire
157
158
Special Audio, Communication
& Instrumentation
159-161
For extreme hard service,
General Cable’s rubber
Low Skew 4-Pair UTP
SmartWrap™ Bundled Cable
162
163
microphone cables offer the
ultimate in performance and
service life. The rubber designs
are highly flexible and designed
to lie flat on studio floors, as
Direct Burial, Audio
& Communication
164-165
166
For more information on these
Digital Audio Snake Cable
well as provide high impact and cables or for other special
abrasion resistance.
applications, please contact
your General Cable sales
representative.
Analog Audio Snake Cable 167-168
Guitar/Instrument Cable
169
For outdoor and cold weather
applications, microphone cable
jacketed with Carolprene®
provides the ultimate protection
against ozone, oil and ultraviolet
radiation.
Ultra Flexible, Low Impedance
2-Conductor Microphone Cable 170
Multi-Conductor, Flexfoil® Shield 171
Multi-Conductor, Rubber,
Braid Shield Microphone Cable 172
Multi-Conductor, Spiral Shield
Multi-Conductor, Braid Shield
173
174
Microphone Cable, Multi-Conductor,
Carolprene®, Braid Shield
175
SMPTE-311 Hybrid Fiber Optic/
Copper Camera Cable
176
177
Electronic News Gathering/Field
Production Camera Cable
146
ELECTRONICS PRODUCT BULLETIN
®
Command Series
Home Entertainment Cables
Carol® Brand Command® Series Speaker Cables offer
•ꢀ ChooseꢀtheꢀproperꢀAWGꢀsizeꢀforꢀyourꢀsystemꢀdesignꢀ(Speakerꢀ
outstanding performance at an affordable price. The
cables are highly flexible and available in a wide variety
of options for in-wall use for home theaters as well as
high definition applications. Whether your choice of speaker
cable is constructed with Oxygen-Free Copper (OFC) or the more
universally accepted Tough Pitch Copper (ETP), your speaker
system will perform as designed and to your expectations.
ꢀ
Impedance,ꢀ4ꢀorꢀ8ꢀohm)ꢀandꢀacceptableꢀlossꢀforꢀtheꢀrequiredꢀ
cable distance.
•ꢀ Chooseꢀanꢀacceptableꢀstrandingꢀthatꢀwillꢀprovideꢀbothꢀeaseꢀofꢀ
installation and flexibility.
•ꢀ Chooseꢀaꢀcableꢀthatꢀisꢀappropriateꢀtoꢀtheꢀinstallationꢀrelativeꢀto
any building standards or codes.
ꢀ
ꢀ
1.ꢀUL/CSA
•ꢀ OFCꢀcopperꢀisꢀdefinedꢀasꢀ99.95%ꢀpure.ꢀTheꢀrefiningꢀprocess
provides reduced oxygen content and other impurities.
2. NEC Riser, Plenum
•ꢀ Selectꢀindividualꢀjacketꢀcolorsꢀasꢀnecessaryꢀtoꢀcontributeꢀtoꢀ
roomꢀorꢀcircuitꢀidentification.ꢀ
•ꢀ Mostꢀimportantly,ꢀchooseꢀtheꢀcableꢀthatꢀyouꢀfeelꢀcomfortableꢀ
•ꢀ HighꢀConductiveꢀElectrolyticꢀToughꢀPitchꢀCopperꢀisꢀtheꢀmostꢀ
ꢀ
ꢀ
ꢀ
widelyꢀusedꢀrefinedꢀcopperꢀwithinꢀtheꢀelectronicꢀcableꢀindustry.ꢀ
Itꢀisꢀdefinedꢀasꢀ99.9%-99.94%ꢀoxygen-freeꢀandꢀprovidesꢀtheꢀꢀ
same level of conductivity as OFC.
ꢀ
with.ꢀIfꢀyouꢀareꢀconvincedꢀthatꢀOFCꢀprovidesꢀaꢀbenefitꢀthatꢀyouꢀ
can hear, select our OFC product. If you choose our speaker
cablesꢀthatꢀutilizeꢀourꢀhigh-conductiveꢀETP,ꢀyouꢀwillꢀhaveꢀ
selectedꢀaꢀcableꢀwithꢀtheꢀsameꢀresistanceꢀforꢀequalꢀcableꢀrunꢀ
distances. The cable resistance is the primary selection criteria.
ꢀ
ꢀ
There are a number of considerations to be made when
choosing the proper speaker cable:
Command® Series PREMIUM-Grade Speaker Cable NEC Type CL2
Applications:
Catalog No.
C1458.55.90
C1458.56.90
C1458.57.90
C1458.15.90
C1461.55.90
C1461.56.90
C1461.57.90
C1461.15.90
C1463.55.90
C1463.56.90
C1463.15.90
Conductors
AWG (Stranding)
16 (105 x 36)
16 (105 x 36)
16 (105 x 36)
16 (105 x 36)
14 (105 x 34)
14 (105 x 34)
14 (105 x 34)
14 (105 x 34)
12 (259 x 36)
12 (259 x 36)
12 (259 x 36)
Length
Digital audio with
high strand, rope
lay construction for
superior flexibility
2
2
2
2
2
2
2
2
2
2
2
25' Coil
50' Coil
100' Coil
250' Spool
25' Coil
50' Coil
100' Coil
250' Spool
25' Coil
50' Coil
250' Spool
Command® Series Home Entertainment Speaker Cable NEC Type CL3, CM, AWM 1/11 A/B
Applications:
Catalog No.
C1700
Conductors
AWG (Stranding)
12 (65 x 30)
12 (65 x 30)
14 (41 x 30)
14 (41 x 30)
16 (26 x 30)
16 (26 x 30)
Length
In-wall speakers
and home theater
systems
2
4
2
4
2
4
500' Boxes
500' Boxes
500' Boxes
500' Boxes
500' Boxes
500' Boxes
C1701
C1702
C1703
C1704
C1705
Command® Series “HIGH DEF” Home Entertainment Speaker Cable NEC Type CL3, CM, AWM 1/11 A/B
Applications:
Catalog No.
C1800
Conductors
AWG (Stranding)
12 (105 x 32)
12 (105 x 32)
14 (105 x 34)
14 (105 x 34)
16 (65 x 34)
Length
2
4
2
4
2
4
500' Reels
500' Reels
500' Boxes
500' Reels
500' Boxes
500' Boxes
Highꢀdefinition,ꢀflexibleꢀ
in-wall speakers and
home theater systems
C1801
C1802
Features:
Oxygen-Free Cu
Conductors
C1803
C1804
C1805
16 (65 x 34)
Semi-extrudedꢀjacketꢀ
provides a uniform round
cable construction
147
Command® Series Home Entertainment Cables
Command® Series Speaker Wire UL Listed (Wires, Misc)
Applications:
Digital audio, stereo
systems
Catalog No.
C1356
Conductors
AWG (Stranding)
24 (7 x 32)
Length
2
2
2
2
2
2
2
500' Reels
500' Reels
500' Reels
500' Reels
500' Reels
500' Reels
500' Reels
C1362
22 (7 x 30)
C1360
20 (10 x 30)
18 (16 x 30)
16 (26 x 30)
14 (41 x 30)
12 (65 x 30)
C1357
C1358
C1361
C1363
Command® Series Twisted Pair Speaker Cable NEC Type CMR
Applications:
Catalog No.
C1000A
C1001A
Conductors
AWG (Stranding)
22 (7 x 30)
Length
Homeꢀtheaters,ꢀ
home audio
systems
2
2
2
2
2
2
500' Reels
500' Reels
500' Reels
500' Reels
500' Reels
500' Reels
20 (7 x 28)
C1002A
C1003A
C1004A
C1005A
18 (7 x 26)
16 (19 x 29)
14 (42 x 30)
12 (65 x 30)
Commercial-Grade Speaker Cables NEC Type CMR
Applications:
Catalog No.
E1042S
Conductors
AWG (Stranding)
16 (19/.0117)
16 (19/.0117)
14 (19/.0147)
14 (19/.0147)
12 (19/.0185)
12 (19/.0185)
Length
2
4
2
4
2
4
500' Reels
500' Reels
500' Reels
500' Reels
500' Reels
500' Reels
Movieꢀtheaters,ꢀ
commercial sound
installations
E1044S
E1052S
E1054S
E1062S
E1064S
Rubber Jacketed Microphone Cable—High- and Low-Impedance
Applications:
Catalog No.
C1300
Conductors
AWG
1
2
2
#20 (26 x 34)
#18 (41 x 34)
#20 (26 x 34)
Low- and high-impedence microphones, broadcast and
studio use, communication and audio systems, shielded
power supplies, control circuits, video and audio
C1301
C1302
interconnecting cables, suggested voltage rating of 300
148
ELECTRONICS PRODUCT BULLETIN
®
Command Series
Cruise Ship Cables
General Cable’s Carol® Brand
Command Series Cruise Ship Cables
are manufactured for use on cruise ships
and yachts. These cables, which contain
low smoke, zero halogen jackets, are
designed to deliver premier audio, video
and data communications capabilities
aboard marine vessels.
The Carol Brand Command Series
Cruise Ship Cables are RoHS
compliant and approved by the
American Bureau of Shipping (ABS)
for use in marine applications.
ABS is the leading international
organization committed to promoting
the security of life, property and the
natural environment primarily through
the development and verification of
standards for the design, construction
and operational maintenance of marine-
related facilities.Their stamp on Carol
Brand Command Series Cruise Ship
Cables means that our cables have been
certified for product compliance and will
perform reliably in marine and off-shore
environments. For more information on
ABS, please visit: www.eagle.org
When your cruise ship or yacht
project requires high-quality
Special Application Cable
Hook-Up Wire
Plenum Cable
performance, think of Carol Brand
Command Series Cruise Ship Cables.
You can always Demand Better…Expect
More™ with General Cable Carol Brand
Electronic cables. We manufacture over
1,300 standard electronic cables that we
can ship direct from stock, and we have
the technical staff and design expertise to
meet any customer cable requirement.
Coaxial Cable
Microphone Cable
Computer Cable
General Purpose Cable
Multi-Conductor Communication
& Control Cable
Multi-Paired Communication
& Control Cable
Fire Alarm Cable
Sound & Security Cable
149
Command® Series Cruise Ship Cables
ABS Listed
Carol® Brand Command® Series Audio Control & Instrumentation Cable–Multi-Pair, Foil Shield
INSULATION
THICKNESS
NOMINAL O.D.
NOM. CAP.* pF/FT
PART
NUMBER
NO. OF
PAIRS
AWG
SIZE
JACKET COLOR/
TEMPERATURE
CONDUCTOR
COLOR CODE
COND. STRAND.
JACKET TYPE
INCHES
mm
INSULATION TYPE
INCHES
mm
A
B
1 Pair
2 Pair
3 Pair
22
22
22
7/30 Tinned
Copper
Flame Retardant
Low Smoke
Halogen Free
Polyolefin PVC
Flame Retardant
Low Smoke
Halogen Free
Polyolefin PVC
Flame Retardant
Low Smoke
Halogen Free
Polyolefin PVC
Black/-30°C
+75°C
0.162
4.11
-40°C to +105°C
Polypropylene
0.008
0.008
0.010
0.20
Black - Red
35
67
C2520ACS
C1352ACS
C6040ACS
7/30 Tinned
Copper
Black/-30°C
+75°C
0.196
0.270
4.98
6.86
-40°C to +105°C
Polypropylene
0.20 P1: Black - Red, P2:
Green - White
35
30
62
55
7/30 Tinned
Copper
Black/-30°C
+75°C
-40°C to +105°C
Polypropylene
0.25 P1: Black - Red, P2:
Black - White, P3:
Black - Green
APPROVALS - (UL) c(UL) Listed Communication CableType CMG-LS 75°C, ABS Listed, & RoHS Compliant
*A - Capacitance between conductors
*B - Capacitance between one conductor and other conductors connected to the shield
Carol® Brand Command® Series RG-6 Coaxial Cable
INSULATION
THICKNESS
NOMINAL O.D.
NOMINAL ATTENUATION
dB/
NOM. NOMINAL NOM.
PART
NUMBER
JACKET COLOR/
TEMPERATURE INCHES mm
INSULATION
TYPE
IMP.
VEL. OF
PROP.
CAP.**
pF/FT
dB/
100 FT
DESCRIPTION
JACKET TYPE
INCHES mm
(Ω)
MHz
100 FT
MHz
5.00
55.00
211.00
270.00
300.00
350.00
400.00
450.00
1.00
0.67
1.60
2.87
3.24
3.43
3.72
4.00
4.26
0.24
0.45
0.54
0.63
0.72
1.57
1.60
1.75
1.84
2.10
2.16
2.42
0.20
0.45
0.64
1.46
2.10
550
750
4.71
5.59
6.00
6.54
8.30
9.30
10.60
11.90
2.97
3.43
4.25
4.95
5.00
5.89
7.33
8.57
9.14
10.67
13.29
—
18 AWG Solid
Copper-Clad Steel,
Dual Shielded,
CATV Coaxial
Cable
Flame Retardant Black/-30°C 0.274 6.96 Gas Injected 0.0700 1.78 75 3
83%
16.2
C5775ACS
Low Smoke
Halogen Free
Polyolefin PVC
+75°C
Foam
870
Polyethylene
1000
1450
1800
2250
3000
270
18 AWG Solid
Bare Copper, Dual
Shielded, Video
Coaxial Cable
Flame Retardant Black/-30°C 0.274 6.96 Gas Injected 0.0700 1.78
75
82%
16.2
C5814ACS
3.58
360
Low Smoke
Halogen Free
Polyolefin PVC
+75°C
Foam
5.00
7.00
540
Polyethylene
720
10.00
67.50
71.50
88.50
100.00
135.00
143.00
180.00
1.00
750
1000
1500
2000
2250
3000
4500
—
200
3.00
4.30
5.80
6.70
7.10
Element 1 - 18
AWG Solid Bare
Copper, Video
Coaxial Cable
Flame Retardant Black/-30°C 0.275 6.99 Gas Injected 0.0700 1.78
75
83%
—
16.3
C8029ACS
5.00
400
Low Smoke
Halogen Free
Polyolefin PVC
+75°C
Foam
10.00
50.00
100.00
700
Polyethylene
900
1000
Element 2 - 2 Cond.
18 AWG 7/.0152”
Stranded Bare
Flame Retardant Black/-30°C 0.186 4.72
-40°C to
+105°C
Polypropylene
0.0065 0.17
—
24**
—
—
Low Smoke
Halogen Free
Polyolefin PVC
+75°C
Copper, Power Pair
APPROVALS - (UL) c(UL) Listed Communication CableType CMG-LS 75°C, ABS Listed, & RoHS Compliant
** Capacitance between conductors
Carol® Brand Command® Series Category 5e Cable
INSULATION
THICKNESS
PSCAR
ACR
ATTENUATION PSNEXT
NEXT
PSELFEXT
ELFEXT
RL
INPUT
IMP.
(Ω)
NOMINAL O.D.
JACKET COLOR/
TEMPERATURE INCHES mm
FRE-
QUENCY
VALUES ARE EXPRESSED IN dB PER 100m (328 FT) LENGTH
PART
NUMBER
JACKET
TYPE
INSULATION
TYPE
CONDUCTOR
COLOR CODE
DESCRIPTION
INCHES mm
MIN. MIN.
MAX.
MIN. MIN.
MIN.
MIN. MIN.
4 Pair 24 AWG
Solid Bare
Flame
Black/-20°C
+75°C
0.260 6.60
Polyolefin
0.010 0.25 P1: White/Blue - Blue
P2: White/Orange -
100 15
0.772 62.2 65.2
1.000 60.3 63.3
4.000 49.2 52.2
8.000 43.0 46.0
10.000 40.8 43.8
16.000 36.1 39.1
20.000 33.5 36.5
25.000 30.9 33.9
31.250 28.2 31.2
62.500 18.4 21.4
100.000 10.3 13.3
1.8
2.0
64.0 67.0 63.0 66.0
—
CR5ACS
62.3 65.3 60.8 63.8 20.0
53.3 56.3 48.7 51.7 23.0
48.8 51.8 42.7 45.7 24.5
47.3 50.3 40.8 43.8 25.0
44.3 47.3 36.7 39.7 25.0
42.8 45.8 34.7 37.7 25.0
41.3 44.3 32.8 35.8 24.3
39.9 42.9 30.9 33.9 23.6
35.4 38.4 24.8 27.8 21.5
32.3 35.3 20.8 23.8 20.1
Retardant
4.1
Copper ScTP Low Smoke
Orange
5.8
Category 5e
Cable
Halogen
Free
Polyolefin
PVC
P3: White/Green - Green
P4: White/Brown - Brown
6.5
8.2
9.3
10.4
11.7
17.0
22.0
APPROVALS - (UL) c(UL) Listed Communication CableType CMG-LS 75°C, ABS Listed, & RoHS Compliant
150
Audio/Video & Home Entertainment Cable
Electronics
Command® Series Premium Grade Speaker Cable
NEC Type CL2
®
Product Description:
Product Construction:
Conductor:
•ꢀꢀ16ꢀthroughꢀ12ꢀAWGꢀfullyꢀannealedꢀ
stranded bare copper conductor per
ASTM B-3
Features:
Command® Series Premium Grade Speaker
Cable was designed to offer outstanding
performance at an affordable price. The
cables are highly flexible and can be used
for in-wall installations, making them ideal
for use in home theater systems.
ꢀ
•ꢀꢀHigh-strand,ꢀrope-layꢀconductorsꢀgiveꢀ
the cable extra flexibility
ꢀ
ꢀ
•ꢀꢀConvenientꢀfootageꢀandꢀpolarityꢀmarkers,ꢀ
at one-foot intervals to make installation
easy
Insulation:
ꢀ
•ꢀꢀPaintableꢀtoꢀmatchꢀanyꢀdécor
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀclearꢀPVC
The Premium Grade Speaker Cable is
available in 250' spools for custom-cut
lengths, and in 25-, 50- and 100-foot clam-
shells. The packaged cables are ideal for
display on pegboard, gondolas or H-frame
shelves.
Compliances:
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+60°C
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL2
Applications:
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀDigitalꢀaudio
•ꢀꢀStereoꢀsystems
•ꢀꢀIn-wallꢀspeakers
•ꢀꢀHomeꢀtheater
COLOR
OF
JACKET
PKG
PER
CARTON
WEIGHT
CARTON
DIMENSIONS
(H x W x D)
CATALOG
NUMBER
NO. OF
COND.
AWG
SIZE
COND.
STRAND LENGTH
PACKAGE
TYPE
CARTON
CUBE
CARTON (LBS)
UPC NUMBER
16 AWG CONDUCTORS
2
2
2
2
16
16
16
16
66/34
66/34
66/34
66/34
25'
50'
Clear
Clear
Clear
Clear
Coil
6
6
6
1
6.4 12.5 x 8.1 x 10.0 0.586
10.4 12.5 x 8.1 x 10.0 0.586
18.6 15.5 x 8.1 x 10.0 0.727
0 79407 76307 8
0 79407 76308 5
0 79407 76309 2
0 79407 76273 6
C1458.55.90
C1458.56.90
C1458.57.90
C1458.15.90
Coil
100'
250'
Coil
Spool
8.5
6.6 x 6.6 x 6.3
0.159
14 AWG CONDUCTORS
2
2
2
2
14
14
14
14
105/34
105/34
105/34
105/34
25'
50'
Clear
Clear
Clear
Clear
Coil
6
6
6
1
8.5 12.5 x 8.1 x 10.0 0.586
14.5 12.5 x 8.1 x 10.0 0.586
27.0 15.5 x 8.1 x 10.0 0.727
0 79407 76310 8
0 79407 76311 5
0 79407 76312 2
0 79407 76274 3
C1461.55.90
C1461.56.90
C1461.57.90
C1461.15.90
Coil
100'
250'
Coil
Spool
11.5
6.6 x 6.6 x 6.3
0.159
12 AWG CONDUCTORS
2
2
2
12
12
12
259/36
259/36
259/36
25'
50'
Clear
Clear
Clear
Coil
6
6
1
11.8 12.5 x 8.1 x 10.0 0.586
21.4 15.5 x 8.1 x 10.0 0.727
0 79407 76313 9
0 79407 76314 6
0 79407 76275 0
C1463.55.90
C1463.56.90
C1463.15.90
Coil
250'
Spool
17.5 13.0 x 6.5 x 9.5
0.464
151
Electronics
Audio/Video & Home Entertainment Cable
Command® Series Home Entertainment Speaker Cable
NEC Type CL3, CSA, CMG, AWM I/II A/B
®
NOM. INSULATION
WALL
NOM. JACKET
THICKNESS
NOMINAL O.D.
CATALOG
NUMBER
NO. OF
COND.
AWG
SIZE
COND.
STRAND
Product Construction:
Conductor:
INCHES
mm
INCHES
mm
INCHES
mm
†
2
4
2
4
2
4
12
12
14
14
16
16
65/30
65/30
41/30
41/30
26/30
26/30
0.009
0.009
0.009
0.009
0.009
0.009
0.15
0.15
0.15
0.15
0.15
0.15
0.021
0.021
0.021
0.021
0.021
0.021
0.53
0.53
0.53
0.53
0.53
0.53
0.254
0.299
0.220
0.257
0.191
0.222
6.45
7.59
5.59
6.53
4.85
5.64
C1700
C1701
C1702
C1703
C1704
C1705
ꢀ
•ꢀꢀ12,ꢀ14,ꢀ16,ꢀorꢀ18ꢀAWGꢀfullyꢀannealed,ꢀ
†
†
†
stranded bare copper per ASTM B-8
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀcommandꢀblue
†CL3, CSA AWM I/II A/B only
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+60˚C
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀDigitalꢀaudio
Color Code Chart
•ꢀꢀStereoꢀsystems
•ꢀꢀIn-wallꢀspeakers
•ꢀHomeꢀtheater
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀSecurityꢀsystems
•ꢀꢀBi-ampꢀspeakers
NO. OF
COND.
COLOR
Black
Red
1
2
3
4
White
Green
Features:
ꢀ
•ꢀꢀFlexible
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL3ꢀ
(UL:ꢀ60°C)
ꢀ
ꢀ
ꢀ
•ꢀCSA,ꢀCMG,ꢀAWMꢀI/IIꢀA/B
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
Vertical Tray Flame Test
ꢀ
•ꢀꢀPassesꢀCSAꢀFT-4ꢀVerticalꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Canadian
Standard
Association
152
Audio/Video & Home Entertainment Cable
Electronics
Command® Series OFHC Home Entertainment Speaker Cable
CL3ꢀ(UL),ꢀCMꢀ(UL)ꢀc(UL),ꢀCSA,ꢀCMG,ꢀCSAꢀTYPEꢀAWM
NOM.
®
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL O.D.
C-C
CAP.*
pF/ft
CATALOG NO. OF AWG
COND.
NUMBER COND. SIZE STRAND INCHES
mm
INCHES
mm
INCHES
mm
Product Construction:
Conductor:
•ꢀꢀ16-12ꢀAWGꢀfullyꢀannealed,ꢀstrandedꢀ
oxygen-free high conductivity bare
copper per ASTM B-170
2
4
2
4
2
4
12
12
14
14
16
16
105/32 0.009
105/32 0.009
105/34 0.009
105/34 0.009
0.23
0.23
0.23
0.23
0.23
0.23
0.021
0.021
0.021
0.021
0.021
0.021
0.53
0.53
0.53
0.53
0.53
0.53
0.264
0.311
0.226
0.265
0.196
0.228
6.71
7.90
5.74
6.73
4.98
5.79
25.5
25.5
23.8
23.8
22.1
22.1
C1800**
C1801**
C1802**
C1803**
C1804
ꢀ
Insulation:
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polypropylene
ꢀ
64/34
65/34
0.009
0.009
Jacket:
C1805
ꢀ
ꢀ
•ꢀꢀPVC,ꢀcommandꢀblue
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+60˚C
*Capacitance between conductors
**NEC Type CL3 and CSA Type AWM Only
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀDigitalꢀaudio
Color Code Chart
•ꢀꢀStereoꢀsystems
•ꢀꢀIn-wallꢀspeakersꢀ
•ꢀHomeꢀtheater
•ꢀꢀRemoteꢀcontrolꢀcircuits
•ꢀꢀSecurityꢀsystems
•ꢀꢀBi-ampꢀspeakers
NO. OF
COND.
COLOR
Black
Red
1
2
3
4
White
Green
Features:
ꢀ
•ꢀꢀFlexible
ꢀ
•ꢀꢀHighꢀconductivity,ꢀoxygen-free
Compliances:
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL3ꢀ
(UL:ꢀ60°C)
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMꢀ
(UL:ꢀ60°C)
ꢀ
ꢀ
ꢀ
•ꢀꢀCSA,ꢀCMG,ꢀ(CSA:ꢀ80°C,ꢀ600V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
Vertical Tray Flame Test
ꢀ
•ꢀꢀPassesꢀCSAꢀFT-4ꢀVerticalꢀFlameꢀTest
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Canadian
Standard
Association
153
Electronics
Audio/Video & Home Entertainment Cable
Command® Series Twisted Pair Speaker Cable
CMRꢀ(UL)ꢀc(UL)ꢀorꢀCL3ꢀ(UL),ꢀAWMꢀStyleꢀ2587
®
NOM.
C-C
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
CAP.*
pF/ft
Product Construction:
Conductor:
NUMBER COND. SIZE STRAND INCHES
mm
INCHES
mm
INCHES
mm
NEC Type CMR
ꢀ
•ꢀꢀ22-12ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
2
2
2
2
22
20
18
7/30
7/28
7/26
0.015
0.38
0.33
0.56
0.58
0.025
0.64
0.64
0.71
0.81
0.170
0.178
0.235
0.274
4.32
4.52
5.97
6.96
20.6
24.5
21.3
23.5
C1000A
C1001A
C1002A
C1003A
tinned copper per ASTM B-33
0.013
0.022
0.025
0.028
0.032
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀS-RꢀPVC
16 19/.0117 0.023
Jacket:
NEC Type CL3, UL Style 2587 (600V)
ꢀ
ꢀ
•ꢀꢀPVC,ꢀwhite
2
2
14
12
41/30
65/30
0.031
0.032
0.79
0.81
0.032
0.035
0.81
0.89
0.340
0.386
8.64
9.80
30.3
32.6
C1004A*
C1005A*
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀDigitalꢀaudio
•ꢀꢀStereoꢀsystems
•ꢀꢀIn-wallꢀspeakers
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
*Capacitance between conductors.
Color Code Chart
C1000A-C1001A
Compliances:
NO. OF
ꢀ
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ
(UL,ꢀc(UL):ꢀ75°C)
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL3ꢀ
(UL,ꢀc(UL):ꢀ105°C)
•ꢀꢀUL,ꢀc(UL)ꢀAWMꢀStyleꢀ2587ꢀ
(UL,ꢀc(UL):ꢀ90°C)
COND.
COLORS
Black
Red
1
2
C1002A-C1005A
ꢀ
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
Vertical Tray Flame Test
NO. OF
COND.
COLORS
Black
White
1
2
Packaging and Jacket Colors:
ꢀ
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
packaging and color options
154
Audio/Video & Home Entertainment Cable
Electronics
Command® Series Studio Grade Speaker Cable
NEC Type CL2
®
Product Description:
Product Construction:
Conductor:
•ꢀꢀ16ꢀthroughꢀ12ꢀAWGꢀfullyꢀannealedꢀ
stranded silver-plated conductor per
ASTM B-3
Features:
ꢀ
ꢀ
ꢀ
•ꢀꢀSilver-platedꢀconductorꢀlowersꢀelectricalꢀ
Command® Series Studio Grade Speaker
Cable brings sounds to life. It is engineered
to deliver the true fidelity of a music signal
from the source to the speaker—maintaining
the highest signal integrity for ultimate clarity.
It is the perfect speaker cable for the dis-
criminating audiophile.
resistance for superior signal rendition
•ꢀꢀHigh-strand,ꢀrope-layꢀconductorsꢀgiveꢀ
the cable extra flexibility
•ꢀꢀConvenientꢀfootageꢀandꢀpolarityꢀmarkers,ꢀ
at one-foot intervals to make installation
easy
ꢀ
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀclearꢀblueꢀPVC
ꢀ
•ꢀꢀPaintableꢀtoꢀmatchꢀanyꢀdécor
•ꢀꢀTemperatureꢀrange:ꢀ0°Cꢀtoꢀ+60°C
Compliances:
Applications:
ꢀ
•ꢀꢀNECꢀArticleꢀ725ꢀTypeꢀCL2
ꢀ
ꢀ
ꢀ
•ꢀꢀDigitalꢀaudio
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀStereoꢀsystems
•ꢀꢀIn-wallꢀspeakersꢀ
PKG
PER
CARTON
WEIGHT
CARTON
DIMENSIONS
(H x W x D)
CATALOG
NUMBER
NO. OF
COND.
AWG
SIZE
COND.
COLOR
PACKAGE
TYPE
CARTON
CUBE
STRAND LENGTH OF JACKET
CARTON (LBS)
UPC NUMBER
16 AWG CONDUCTORS
2
2
2
16
14
12
105/36
168/36
259/36
250’
250’
250’
Clear Blue
Spool
1
8.5
6.6 x 6.6 x 6.3
6.6 x 6.6 x 6.3
0.159
0.159
0.464
0 79407 76276 7
C1558.15.92
C1561.15.92
C1563.15.92
14 AWG CONDUCTORS
Clear Blue
Spool
1
11.5
0 79407 76280 4
0 79407 76280 4
12 AWG CONDUCTORS
Clear Blue
Spool
1
17.5 13.0 x 6.5 x 9.5
155
Electronics
Audio/Video & Home Entertainment Cable
Speaker Wire
ULꢀListedꢀorꢀAWMꢀStyleꢀ1007
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀthruꢀ12ꢀAWGꢀfullyꢀannealedꢀoneꢀ
bare, one tin stranded copper per
ASTMꢀB-174
Insulation/Jacket:
•ꢀꢀPremium-gradeꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
ꢀ
ꢀ
NOM. INSULATION
THICKNESS
NUMBER
NOMINAL O.D.
INCHES mm
CATALOG
NUMBER
OF
AWG
SIZE
COND.
COND.
STRAND
INCHES
mm
Applications:
•ꢀꢀDigitalꢀaudio
•ꢀꢀHi-fiꢀandꢀstereoꢀspeakerꢀwire
•ꢀꢀJukeboxes
•ꢀꢀNotꢀforꢀin-wallꢀuse
•ꢀꢀHomeꢀtheater
UL LISTED (60°C)
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
2
2
2
2
2
2
2
24
22
20
18
16
14
12
7/32
7/30
0.016
0.020
0.020
0.020
0.020
0.025
0.025
0.41
0.51
0.51
0.51
0.51
0.64
0.64
0.058x0.117 1.47x2.79
0.070x0.145 1.77x3.68
0.085x0.160 2.16x4.06
0.083x0.181 2.11x4.60
0.105x0.210 2.67x5.33
0.125x0.235 3.18x5.69
0.154x0.323 3.91x8.20
C1356
C1362
C1360
C1357
C1358
C1361
C1363
10/30
16/30
26/30
41/30
65/30
Compliances:
•ꢀꢀULꢀWiresꢀMisc.
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
ꢀ
ꢀ
Packaging:
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀ
forpackagingꢀandꢀcolorꢀoptions
ꢀ
Color Code Chart
ORDERING
SUFFIX
COLORS
Black
White
Brown
Gray
01
02
08
10
Clear
90
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀAWGꢀtinnedꢀannealedꢀstrandedꢀ
copper
ꢀ
•ꢀꢀStrandedꢀtinnedꢀcopperꢀperꢀASTMꢀB-33
Insulation:
ꢀ
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcolor-codedꢀPVC
•ꢀꢀTemperatureꢀrange:ꢀ-30˚Cꢀtoꢀ+80˚C
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION
THICKNESS
NOMINAL O.D.
CATALOG
NUMBER
NO. OF
COND.
AWG
SIZE
COND.
STRAND
INCHES
mm
INCHES
mm
AWM STYLE 1007 (80°C, 300 V)
Applications:
ꢀ
•ꢀꢀAudioꢀsystems
2
18
7/.0152
0.020
0.51
0.172
4.37
C7102A
ꢀ
•ꢀꢀNotꢀforꢀin-wallꢀuse
Color Code Chart
Compliances:
ꢀ
ORDERING
SUFFIX
STOCK
COLOR
•ꢀꢀULꢀStyleꢀ1007ꢀ(UL:ꢀ80°C,ꢀ300ꢀV)
Black-White
99
Packaging:
ꢀ
•ꢀꢀ1000'ꢀ(305ꢀm)ꢀreels
156
Audio/Video & Home Entertainment Cable
Electronics
Superflex® Speaker Wire
UL Listed
Product Construction:
Conductor:
ꢀ
•ꢀꢀ12ꢀAWGꢀfullyꢀannealedꢀstrandedꢀbareꢀ
copper conductor per ASTM B-3
Insulation/Jacket:
ꢀ
ꢀ
ꢀ
•ꢀPꢀ remium-grade,ꢀclearꢀSuperflex® PVC
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+60°C
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION
THICKNESS
NOMINAL O.D.
CATALOG
NUMBER
NUMBER OF
COND.
AWG
SIZE
COND.
STRAND
INCHES
mm
INCHES
mm
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀDigitalꢀaudio
•ꢀꢀHi-fiꢀandꢀstereoꢀspeakerꢀwire
•ꢀꢀJukeboxes
2
12
7x37/36
0.060
1.52
0.220x0.456 5.59x11.58
C1364
•ꢀꢀNotꢀforꢀin-wallꢀuse
Color Code Chart
Compliances:
ꢀ
ORDERING
SUFFIX
STOCK
COLOR
•ꢀꢀULꢀMisc.ꢀ(UL:ꢀ120V)
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Clear
90
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀAWG,ꢀ1ꢀtinnedꢀandꢀ1ꢀbareꢀcopperꢀ
conductor per ASTM B-174
Insulation:
•ꢀꢀPremium-grade,ꢀclearꢀPVC
ꢀ
NOM. INSULATION
THICKNESS
NOM. JACKET
THICKNESS
Jacket:
NOMINAL O.D.
CATALOG NO. OF AWG
COND.
ꢀ
ꢀ
•ꢀꢀPVC,ꢀclear
NUMBER COND. SIZE STRAND INCHES
mm
INCHES
mm
INCHES
mm
•ꢀꢀTemperatureꢀrange:ꢀ-20˚Cꢀtoꢀ+60˚C
2
18
16/30
0.016
0.41
0.025
0.64
0.210
5.33
C6367
Applications:
ꢀ
ꢀ
ꢀ
•ꢀꢀDigitalꢀaudio
•ꢀꢀHi-fiꢀandꢀstereoꢀspeakerꢀwire
•ꢀꢀJukeboxes
Color Code Chart
Compliances:
ORDERING
SUFFIX
STOCK
COLOR
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Clear
90
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
157
Electronics
Audio/Video & Home Entertainment Cable
Pro Audio Speaker Wire
Product Construction:
Conductor:
ꢀ
•ꢀꢀ12-18ꢀAWGꢀstrandedꢀbareꢀcopper
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
•ꢀꢀPVC
ꢀ
CATALOG
JACKET
& O.D.
WEIGHT
LBS/Mft
NUMBER
740002
740102
740202
740302
CONDUCTOR & O.D.
INSULATION & O.D.
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀmatteꢀblack
2/C 12 AWG Stranded
65/30 Bare Copper
PVC
0.136" Nom.
PVC
0.365" Nom.
100
75
•ꢀꢀHighꢀflexibility
Applications:
2/C 14 AWG Stranded
41/30 Bare Copper
PVC
0.118" Nom.
PVC
0.295" Nom.
ꢀ
ꢀ
ꢀ
•ꢀꢀRecordingꢀstudios
•ꢀꢀCommercialꢀbroadcastꢀfacilities
•ꢀꢀNotꢀforꢀin-wallꢀuse
2/C 16 AWG Stranded
26/30 Bare Copper
PVC
0.102" Nom.
PVC
0.295" Nom.
60
2/C 18 AWG Stranded
41/34 Bare Copper
PVC
0.079" Nom.
PVC
0.235" Nom.
Features:
38
ꢀ
•ꢀꢀHighꢀdurabilityꢀandꢀlong-lastingꢀservice
Packaging and Jacket Colors:
ꢀ
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
packaging, color options and agency
approvals
CATALOG
NUMBER
JACKET
& O.D.
WEIGHT
LBS/Mft
CONDUCTOR & O.D.
INSULATION & O.D.
4/C 12 AWG Stranded
PVC
0.136" Nom.
PVC
0.463" Nom.
165
107
75
740004
740104
740204
740304
65/30 Bare Copper
4/C 14 AWG Stranded
41/30 Bare Copper
PVC
0.118" Nom.
PVC
0.397" Nom.
4/C 16 AWG Stranded
26/30 Bare Copper
PVC
0.102" Nom.
PVC
0.338" Nom.
4/C 18 AWG Stranded
41/34 Bare Copper
PVC
0.079" Nom.
PVC
0.283" Nom.
53
NOTE:ꢀCabledꢀwithꢀjuteꢀfillersꢀandꢀpaperꢀtapeꢀunderꢀjacket.
Color Code Chart
NO. OF
COND.
COLOR
Black
White
Red
1
2
3
4
Green
158
Audio/Video & Home Entertainment Cable
Electronics
Special Audio, Communication & Instrumentation
UL 2095, 2093
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀthruꢀ20ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polyethyleneꢀ(C1333A)ꢀorꢀPVCꢀ(C1345A)
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
NOMINAL O.D.
pF/ft
CATALOG NO. OF
NUMBER COND.
AWG
SIZE
COND.
Shield:
STRAND INCHES mm INCHES mm INCHES mm
A
B
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
withꢀ25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀ
out
UL Style 2093, 300 VOLT
10/30 0.015 0.38 0.028 0.71 0.206 5.23 26.0 47.0
2-20
Shielded
1-20
C1333A
3
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
7/28 0.016 0.41
Unshielded
Jacket:
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
*A – Capacitance between conductors
ꢀ
ꢀ
*B – Capacitance between one conductor and other conductors connected to shield
Applications:
Color Code Chart
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀAudio
NO. OF
COND.
•ꢀꢀCommunications
•ꢀꢀEMIꢀisolatedꢀcircuitsꢀforꢀinstrumentation
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
COLOR
Shielded
Black
Red
1
2
Compliances:
Unshielded
1
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀStyleꢀ2093ꢀ(UL:ꢀ60°C,ꢀ300V)
•ꢀꢀULꢀStyleꢀ2095ꢀ(UL:ꢀ80°C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Natural
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
pF/ft
NOMINAL O.D.
CATALOG NO. OF
NUMBER COND.
AWG
SIZE
COND.
STRAND INCHES mm INCHES mm INCHES mm
A
B
UL Style 2095, 300 VOLT
4-24
Shielded
2-22
7/32 0.015 0.38 0.025 0.64 0.230 5.84 32.0 57.0
C1345A
6
7/30
Unshielded
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart
NO. OF
COND.
COLOR
Shielded
Black
Red
1
2
Green
Yellow
3
4
Unshielded
Blue
White
1
2
159
Electronics
Audio/Video & Home Entertainment Cable
Special Audio, Communication & Instrumentation
UL 2095, UL 2835, UL 2094, NEC Type CL2
Product Construction:
Conductor:
•ꢀꢀ22ꢀthruꢀ18ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
ꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀC1331Aꢀ-ꢀPremium-grade,ꢀcoIor-codedꢀ
PVC
•ꢀꢀC1340Aꢀ-ꢀPremium-grade,ꢀcoIor-codedꢀ
polypropylene
•ꢀꢀC1343Aꢀ-ꢀPremium-grade,ꢀcoIor-codedꢀ
polyethylene
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
pF/ft
NOMINAL O.D.
CATALOG NO. OF
NUMBER COND.
AWG
SIZE
COND.
STRAND INCHES mm INCHES mm INCHES mm
A
B
UL Style 2095, NEC Type CL2
7/28 0.016 0.41 0.032 0.81 0.230 5.84 41.0 74.0
•ꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
4
4
4
2-20
Shielded
2-20
C1331A
C1340A
C1343A
Shield:
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester over
twoꢀconductors,ꢀ25%ꢀoverlap,ꢀminimum,ꢀ
foil facing out
Unshielded
UL Style 2835
7/30 0.008 0.20 0.017 0.43 0.161 4.09 29.0 52.0
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
2-22
Shielded
2-22
Jacket:
•ꢀPVC,ꢀgray
•ꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
Unshielded
ꢀ
ꢀ
UL Style 2094
7/28 0.018 0.46 0.032 0.81 0.259 6.58 27.0 49.0
2-20
Shielded
2-18
Applications:
•ꢀAudio
•ꢀCommunications
•ꢀEMIꢀisolatedꢀcircuitsꢀforꢀinstrumentation
16/30
ꢀ
ꢀ
ꢀ
Unshielded
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Compliances:
ꢀ
•ꢀꢀNecꢀArticleꢀ725ꢀTypeꢀCL2
(UL:ꢀ75°C,ꢀ150V)
Color Code Chart
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀC1331Aꢀ-ꢀULꢀStyleꢀ2095ꢀ(UL:ꢀ80°C)
•ꢀC1340Aꢀ-ꢀULꢀStyleꢀ2835ꢀ(UL:ꢀ60°C)
•ꢀC1343Aꢀ-ꢀULꢀStyleꢀ2094ꢀ(UL:ꢀ60°C)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀ70,000ꢀBTUꢀ
Vertical Tray Flame Test
NO. OF
COND.
COLOR
Shielded
Black
Red
1
2
Unshielded
Packaging:
ꢀ
Green
White
1
2
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
160
Audio/Video & Home Entertainment Cable
Electronics
Special Audio, Communication & Instrumentation
UL 2094
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polyethylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
NOMINAL O.D.
pF/ft
CATALOG NO. OF
NUMBER PAIRS
AWG
SIZE
COND.
STRAND INCHES mm INCHES mm INCHES mm
A
B
Shield:
ꢀ
•ꢀꢀ64%ꢀtinnedꢀcopperꢀbraidꢀoverꢀoneꢀpair
2
1-22
Shielded
1-22
7/30 0.015 0.38 0.030 0.76 0.295 7.49 24.0 43.0
C1338A
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
Unshielded
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+60°C
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Applications:
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀSpecialꢀaudio
•ꢀꢀCommunicationꢀandꢀcontrol
•ꢀꢀInstrumentation
•ꢀꢀApplicationsꢀwhereꢀtotalꢀisolationꢀofꢀ
Color Code Chart
NO. OF
PAIRS
COLOR
signal is required
ꢀ
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Black/Natural
Black/Natural
1
2
Compliances:
ꢀ
ꢀ
ꢀ
•ꢀꢀULꢀStyleꢀ2094ꢀ(UL:ꢀ60°C,ꢀ300V)
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
•ꢀꢀDesignedꢀtoꢀmeetꢀULꢀVW-1ꢀVerticalꢀWireꢀ
Flame Test
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
161
Electronics
Audio/Video & Home Entertainment Cable
Low Skew 4-Pair UTP
NECꢀTypeꢀCMR/CMPꢀ(UL),ꢀc(UL)ꢀ
Product Construction:
Conductor:
Applications:
Color Code Chart
ꢀ
•ꢀꢀSuitableꢀforꢀRGBꢀvideoꢀapplications
NO. OF
PAIRS
COLOR
ꢀ
•ꢀꢀDigitalꢀCCTVꢀcameras
ꢀ
•ꢀꢀ23ꢀorꢀ24ꢀAWGꢀsolidꢀbareꢀcopper
White/Blue Stripe and Blue
White/Orange Stripe and Orange
White/Green Stripe and Green
White/Brown Stripe and Brown
1
2
3
4
Compliances:
Insulation:
ꢀ
•ꢀNECꢀArticleꢀ800ꢀTypeꢀCMRꢀ(UL),ꢀc(UL)
ꢀ
ꢀ
•ꢀFluorinatedꢀethyleneꢀpropyleneꢀ(FEP)
ꢀ
•ꢀNECꢀArticleꢀ800ꢀTypeꢀCMPꢀ(UL),ꢀc(UL)
•ꢀHighꢀdensityꢀpropyleneꢀ(HDPE)
Packaging:
Jacket:
ꢀ
•ꢀꢀ1000'ꢀPull-Pacs®
ꢀ
ꢀ
•ꢀPꢀ lenumꢀ-ꢀFlexguard® green
•ꢀꢀRiserꢀ-ꢀPVCꢀmaroon
ꢀ
•ꢀꢀContactꢀCustomerꢀServiceꢀforꢀadditionalꢀ
packaging options
INSULATION
NOMINAL
NOMINAL
O.D.
(INCHES)
NOMINAL
MATERIAL
ATTENUATION
CATALOG
NUMBER
AWG
SIZE
NOMINAL
DCR
IMPEDANCE PROPAGATION
BELDEN
INCHES
mm
OHMS
DELAY SKEW
MHz
dB/328 ft. PART NO.
24 AWG
Solid Bare Ω/Mft
Copper
27.4
0.185 Fluorinated Ethylene
100
2.2 ns/328 ft.
1
4
2.0
4.1
7987P
7987R
7989P
7989R
E3842S
CMP
Propyleneꢀ(FEP)
8
5.8
10
6.5
16
8.2
20
9.3
0.035
0.9
25
10.4
11.7
17.0
22.0
28.1
32.0
36.4
41.0
44.8
31.25
62.50
100
155
200
250*
300*
350*
24 AWG
Solid Bare Ω/Mft
Copper
27.4
0.185
High Density
Propyleneꢀ(HDPE)
100
100
100
2.2 ns/328 ft.
2.2 ns/328 ft.
2.2 ns/328 ft.
1
4
2.0
4.1
E1842S
CMR
8
5.8
10
6.5
16
8.2
20
9.3
0.035
0.9
25
10.4
11.7
17.0
22.0
28.1
32.0
36.4
41.0
44.8
31.25
62.50
100
155
200
250*
300*
350*
23 AWG
Solid Bare Ω/Mft
Copper
22.0
0.200 Fluorinated Ethylene
1
4
2.0
3.8
E3843S
CMP
Propyleneꢀ(FEP)
8
5.3
10
6.0
16
7.6
20
8.5
0.040
1.0
25
9.5
31.25
62.50
100
155
200
250
300*
350*
10.7
15.4
19.8
25.2
29.0
32.8
35.2
39.8
23 AWG
Solid Bare Ω/Mft
Copper
22.0
0.213
High Density
Propyleneꢀ(HDPE)
1
4
2.0
3.8
E1843S
CMR
8
5.3
10
6.0
16
7.6
20
8.5
0.040
1.0
25
9.5
31.25
62.50
100
155
200
250*
300*
350*
10.7
15.4
19.8
25.2
29.0
32.8
35.2
39.8
*For information only.
162
Audio/Video & Home Entertainment Cable
Electronics
SmartWrap™ Bundled Cable
MultipleꢀCableꢀTypesꢀDependingꢀOnꢀApplicationꢀUpꢀtoꢀ6ꢀCablesꢀ/ꢀJacketedꢀandꢀUnjacketed
Product Construction:
Fiber:
ꢀ
•ꢀꢀMultimodeꢀorꢀsinglemodeꢀfibersꢀwithꢀ
easily strippable 900µm tight buffering
colored per TIA/EIA 598
ꢀ
•ꢀꢀCabledꢀwithꢀaramidꢀyarnꢀstrengthꢀ
member and jacketed to meet
appropriate standards
CATALOG
NUMBER
SAFETY RATING
BINDING OR
JACKET
CONSTRUCTION
4 Carol® Brand Cat 5e UTP
Coax:
ꢀ
•ꢀꢀQuadꢀshieldꢀRG6ꢀcoaxꢀwithꢀcopper-cladꢀ
steel center conductor, either foamed
PEꢀ(riser)ꢀorꢀFEPꢀ(plenum)ꢀdielectricꢀandꢀ
overall PVC jacket
Riser
Plenum
Riser
Binding
Binding
Binding
Binding
Binding
Binding
Binding
Binding
710021
810021
710022
810022
710023
810023
710024
810024
4 Carol® Brand Cat 5e UTP
6 Carol® Brand Cat 5e UTP
6 Carol® Brand Cat 5e UTP
4 Carol® Brand Cat 5e ScTP
4 Carol® Brand Cat 5e ScTP
6 Carol® Brand Cat 5e ScTP
6 Carol® Brand Cat 5e ScTP
Twisted Pair:
•ꢀUꢀ nshielded or shielded twisted pair that
ꢀ
ꢀ
meets or exceeds all TIA/EIA 568 B-2
Plenum
Riser
standards for Carol® Brand Cat 5e
Binder:
•ꢀꢀHelicallyꢀwoundꢀpolyesterꢀbinder
Plenum
Riser
Overall Jacket (Optional):
•ꢀꢀRiser-ratedꢀversionsꢀuseꢀaꢀflame-
ꢀ
Plenum
retardant PVC
2 Carol® Brand Cat 5e UTP and 2 RG6 Quad
Smart Home coax
Applications:
Riser
Riser
Riser
Riser
Jacket
Jacket
Binding
Binding
710010
710011
710017
710018
ꢀ
•ꢀSꢀ martWrap™ cables are several different
2 Carol® Brand Cat 5e UTP, 2 RG6 Quad Smart
Home coax and 2 simplex multimode fiber cables
cables available with either helical binding
or overall jacketing to allow simultaneous
pulling of multiple cables. Configurations
include combinations of Cat 5e UTP or
ScTP, RG6 video/data quad shield coax
and optical fiber cables. Plenum and riser
versions available
2 Carol® Brand Cat 5e UTP and 2 RG6 Quad
Smart Home coax
2 Carol® Brand Cat 5e UTP, 2 RG6 Quad Smart
Home coax and 2 simplex multimode fiber cables
Features:
Theꢀaboveꢀlistingsꢀareꢀforꢀstockꢀcables.ꢀCustomꢀconfigurationsꢀareꢀavailable.ꢀInformationꢀisꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
ConsultꢀCustomerꢀServiceꢀforꢀaꢀvarietyꢀofꢀalternateꢀconstructionsꢀforꢀspecificꢀapplications.
ꢀ
•ꢀꢀManyꢀcablesꢀcanꢀbeꢀpulledꢀatꢀonce—
faster installation
ꢀ
ꢀ
ꢀ
•ꢀꢀTIA/EIAꢀ568ꢀB-2ꢀCrosstalk-compliant
•ꢀꢀSimplifiesꢀcableꢀmanagement
•ꢀꢀExcellentꢀforꢀresidentialꢀapplicationsꢀ
Compliances:
ꢀ
ꢀ
•ꢀꢀNECꢀArticleꢀ800ꢀCMR,ꢀCSAꢀFT-4ꢀriser
•ꢀꢀNECꢀArticleꢀ800ꢀCMP,ꢀCSAꢀFT-6ꢀplenum
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
DATA TRANSMISSION PERFORMANCE FOR CAT 5E CABLES
INSERTION LOSS
NEXT
PSNEXT
ACR
PSACR
ELFEXT
PSNEXT
RETURN
LOSS MIN
(dB)
FREQUENCY
(MHZ)
TYPICAL • MAX* TYPICAL • MIN* TYPICAL • MIN* TYPICAL • MIN* TYPICAL • MIN* TYPICAL • MIN* TYPICAL • MIN*
(dB/100m)
(dB)
(dB)
(dB/100m)
(dB/100m)
(dB/100m)
(dB/100m)
1
19.3ꢀ•ꢀ22.0
51.9ꢀ•ꢀ35.3
43.8ꢀ•ꢀ32.3
32.6ꢀ•ꢀ13.3
24.5ꢀ•ꢀ10.3
43.7ꢀ•ꢀ23.8
38.8ꢀ•ꢀ20.8
20.1
*Max/min measurements match TIA/EIA 568 B-2 standards
ELECTRICAL CHARACTERISTICS FOR CAT 5E CABLES
DC Resistance
Input Impedance
100ꢀOhmsꢀ±ꢀ15%ꢀ@ꢀ1ꢀ-ꢀ100ꢀMHz
≤9.38ꢀOhms/100ꢀMetersꢀ•ꢀ28.6ꢀOhms/1000ꢀFeet
DCR Unbalanced
Mutual Capacitance
PropagationꢀDelayꢀ(Skew) 45 nanoseconds/100 meters max
Velocity of Propagation 72%ꢀplenum/69%ꢀriser
≤5%
≤55.8ꢀpF/mꢀ•ꢀ17ꢀpF/ft
ELECTRICAL CHARACTERISTICS FOR RG6 CABLES
≤
Capacitance
Characteristic Impedance
53.2ꢀpF/mꢀ•ꢀ16.2ꢀpF/ft
75 Ohms
Attenuationꢀ(dB/100ꢀft)
Velocity of Propagation
0.21@ꢀ1ꢀMHzꢀ•ꢀ6.04ꢀdBꢀ@ꢀ1000MHz
83%ꢀriser
163
Electronics
Audio/Video & Home Entertainment Cable
Direct Burial, Audio & Communication
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20ꢀAWGꢀfullyꢀannealedꢀsolidꢀtinnedꢀ
copper per ASTM B-33
Insulation:
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
ꢀ
polypropylene
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
pF/ft
NOMINAL O.D.
NUMBER COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
Shield:
CATALOG NO. OF AWG COND.
A
B
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀout
•ꢀꢀSolidꢀtinnedꢀcopperꢀdrainꢀwire
2
3
20
20
20
Solid
Solid
Solid
0.013 0.33 0.037 0.94 0.190 4.83 25.0 44.0
C2509A
C2510A
C2511A
0.013 0.33 0.039 0.99 0.205 5.21 22.0 40.0
0.013 0.33 0.039 0.99 0.310 7.87 20.5 37.0
Jacket:
ꢀ
ꢀ
•ꢀPꢀ ermaline® high-density polyethylene,
10
black
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
Applications:
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀdirectꢀburial
•ꢀOutdoorꢀuses
•ꢀꢀ100%ꢀshieldedꢀcableꢀwhereꢀRFꢀshieldingꢀ
is required
ꢀ
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ350ꢀvolts
Features:
ꢀ
ꢀ
ꢀ
•ꢀPꢀ ermaline® jackets resist deterioration
•ꢀꢀSunlight-resistant
•ꢀꢀHighlyꢀdurableꢀjacket
Compliances:
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
164
Audio/Video & Home Entertainment Cable
Electronics
Direct Burial, Audio & Communication
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
ꢀ
•ꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polypropylene
•ꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
Shield:
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester with
NOMINAL O.D.
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
pF/ft
ꢀ
ꢀ
ꢀ
CATALOG NO. OF AWG COND.
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀin
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwireꢀ
each pair
•ꢀꢀIndividuallyꢀshieldedꢀpairs
A
B
3
6
20
20
10/30 0.013 0.33 0.047 1.19 0.340
8.64 22.0 39.0
C6061A
C6062A
10/30 0.013 0.33 0.047 1.19 0.442 11.23 22.0 39.0
Jacket:
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
•ꢀPꢀ ermaline® high-density polyethylene,
black
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+80°C
Color Code Chart
Applications:
NO. OF
PAIRS
ꢀ
ꢀ
ꢀ
•ꢀꢀSuitableꢀforꢀdirectꢀburial
COLOR
•ꢀOutdoorꢀuses
•ꢀꢀApplicationsꢀwhereꢀtotalꢀisolationꢀofꢀ
signal is required
Black paired with Red
Black paired with White
Black paired with Green
Black paired with Blue
BlackꢀpairedꢀwithꢀYellow
Black paired with Brown
1
2
3
4
5
6
ꢀ
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ350ꢀvolts
Features:
ꢀ
•ꢀPꢀ ermaline® jackets resist deterioration
ꢀ
•ꢀꢀSunlight-resistant
Compliances:
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
165
Electronics
Audio/Video & Home Entertainment Cable
Digital Audio Snake Cable
AES/EBUꢀ110ꢀOhmꢀMulti-PairꢀIndividuallyꢀShieldedꢀ&ꢀJacketed, NEC Type CM/CL2
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀstrandedꢀtinnedꢀcopper
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
•ꢀꢀHigh-densityꢀfoamedꢀpolyethylene
ꢀ
CATALOG
NUMBER
INSULATION
& O.D.
SHIELD
(COV.)
JACKET
& O.D.
WT. IMPED. CAPAC.
#/m OHMS pF/ft.
Shield:
CONDUCTOR
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀwithꢀ24ꢀAWGꢀ
1/PR 24 AWG
Stranded 7/32 Tinned
Copper
HD-Cellular PE Individual Foil w/ 24 AWG Drain
0.066” Nom.
FR-PVC Matte
drain wire
•ꢀꢀOverallꢀfoilꢀshieldꢀwithꢀ18ꢀAWGꢀdrainꢀ
wire
13.5
100
183
250
370
425
110
110
110
110
110
110
12.5
12.5
12.5
12.5
12.5
12.5
740601
740604
740608
740612
740616
740620
Overall Foil w/ 18 AWG Drain Finish 0.176" Nom.
4/PR 24 AWG
Stranded 7/32 Tinned
Copper
HD-Cellular PE Individual Foil w/ 24 AWG Drain
0.066” Nom. Overall Foil w/ 18 AWG Drain Finish 0.525" Nom.
FR-PVC Matte
Jacket:
•ꢀPVC,ꢀmatteꢀblack
•ꢀꢀHigh-flex,ꢀflame-retardant
8/PR 24 AWG
Stranded 7/32 Tinned
Copper
HD-Cellular PE Individual Foil w/ 24 AWG Drain
0.066” Nom. Overall Foil w/ 18 AWG Drain Finish 0.700" Nom.
FR-PVC Matte
ꢀ
ꢀ
12/PR 24 AWG
Stranded 7/32 Tinned
Copper
HD-Cellular PE Individual Foil w/ 24 AWG Drain
0.066” Nom. Overall Foil w/ 18 AWG Drain Finish 0.850" Nom.
FR-PVC Matte
Applications:
•ꢀꢀDigitalꢀaudio
•ꢀꢀInterconnectionꢀandꢀaudioꢀcomponentsꢀ
for console board equipment used in
recording studios, radio and television
stations, and post-production facilities
ꢀ
ꢀ
16/PR 24 AWG
Stranded 7/32 Tinned
Copper
HD-Cellular PE Individual Foil w/ 24 AWG Drain
0.066” Nom. Overall Foil w/ 18 AWG Drain Finish 1.000" Nom.
FR-PVC Matte
20/PR 24 AWG
Stranded 7/32 Tinned
Copper
HD-Cellular PE Individual Foil w/ 24 AWG Drain
0.066” Nom. Overall Foil w/ 18 AWG Drain Finish 1.100" Nom.
FR-PVC Matte
ꢀ
•ꢀꢀSoundꢀsystemꢀinstallations
NOTE:ꢀGeneralꢀCableꢀmanufacturesꢀtheꢀaboveꢀcablesꢀinꢀaꢀwideꢀrangeꢀofꢀalternateꢀAWGꢀsizes,ꢀpairꢀcountsꢀandꢀjacketꢀcolors.
Please consult Customer Service for details.
Features:
ꢀ
•ꢀꢀHighꢀimpedance,ꢀ78%ꢀvelocityꢀandꢀ
low capacitance providing error-free
transmissions over extended distances
ꢀ
ꢀ
•ꢀꢀPVCꢀjacketingꢀcompoundꢀforꢀultimateꢀ
cosmetics, durability and flexibility
•ꢀꢀJacketedꢀpairsꢀcanꢀbeꢀsplitꢀoutꢀofꢀoverallꢀ
jacket for any length without use of heat-
shrink tubing
ꢀ
•ꢀꢀIndividualꢀpairꢀjacketsꢀareꢀcolor-
coded and number-printed for easy
identification
Compliances:
ꢀ
ꢀ
ꢀ
•ꢀNECꢀArticleꢀ725ꢀTypeꢀCL2
•ꢀNECꢀArticleꢀ800ꢀTypeꢀCM
•ꢀꢀMeets/exceedsꢀrequirementsꢀofꢀAudioꢀ
EngineeringꢀSocietyꢀ(AES)ꢀandꢀEuropeanꢀ
BroadcastꢀUnionꢀ(EBU)
Packaging and Jacket Colors:
ꢀ
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
packaging and color options
166
Audio/Video & Home Entertainment Cable
Electronics
Analog Audio Snake Cable
70ꢀOhmꢀLowꢀCapacitanceꢀMulti-PairꢀIndividuallyꢀShieldedꢀ&ꢀJacketed,ꢀNECꢀTypeꢀCM/CL2
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀstrandedꢀtinnedꢀcopper
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
•ꢀPolyolefin
ꢀ
CATALOG
NUMBER
INSULATION
& O.D.
SHIELD
(COV.)
JACKET
& O.D.
WT. IMPED. CAPAC.
#/m OHMS pF/ft
Shield:
CONDUCTOR
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀwithꢀ24ꢀAWGꢀ
drain wire
•ꢀꢀOverallꢀfoilꢀshieldꢀ24ꢀAWGꢀdrainꢀwire
STRANDED CONDUCTORS
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
1/PR 24 AWG Stranded
7/32 Tinned Copper
Polyolefin
0.024” Nom.
FR-PVC Matte
Finish 0.137" Nom.
11
64
65
65
65
65
65
65
65
65
65
24
24
24
24
24
24
24
24
24
740501
740504
740508
740512
740516
740520
740528
740542
740552
Jacket:
•ꢀPVC,ꢀmatteꢀblack
•ꢀꢀHigh-flex,ꢀflame-retardant
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
ꢀ
ꢀ
4/PR 24 AWG Stranded
7/32 Tinned Copper
Polyolefin
0.024” Nom.
FR-PVC Matte
Finish 0.385" Nom.
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
Applications:
•ꢀAnalogꢀaudio
•ꢀꢀLineꢀlevelꢀmicrophone
•ꢀꢀInterconnectionꢀandꢀaudioꢀcomponentsꢀ
for console board equipment used in
recording studios, radio and television
stations, and post-production facilities
8/PR 24 AWG Stranded
7/32 Tinned Copper
Polyolefin
0.024” Nom.
FR-PVC Matte
Finish 0.490" Nom.
107
160
205
248
340
485
595
ꢀ
ꢀ
ꢀ
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
12/PR 24 AWG Stranded
7/32 Tinned Copper
Polyolefin
0.024” Nom.
FR-PVC Matte
Finish 0.610" Nom.
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
16/PR 24 AWG Stranded
7/32 Tinned Copper
Polyolefin
0.024” Nom.
FR-PVC Matte
Finish 0.680" Nom.
ꢀ
•ꢀꢀSoundꢀsystemꢀinstallations
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
20/PR 24 AWG Stranded
7/32 Tinned Copper
Polyolefin
0.024” Nom.
FR-PVC Matte
Finish 0.700" Nom.
Features:
•ꢀꢀPVCꢀjacketingꢀcompoundꢀforꢀsuperiorꢀ
cosmetics, durability and flexibility
•ꢀꢀIndividuallyꢀshieldedꢀandꢀjacketedꢀpairsꢀ
with an overall shield
•ꢀꢀIndividualꢀpairꢀjacketsꢀalpha-numericallyꢀ
numbered for easy identification
ꢀ
ꢀ
ꢀ
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
28/PR 24 AWG Stranded
7/32 Tinned Copper
Polyolefin
0.024” Nom.
FR-PVC Matte
Finish 0.820" Nom.
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
42/PR 24 AWG Stranded
7/32 Tinned Copper
Polyolefin
0.024” Nom.
FR-PVC Matte
Finish 1.050" Nom.
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
52/PR 24 AWG Stranded
7/32 Tinned Copper
Polyolefin
0.024” Nom.
FR-PVC Matte
Finish 1.150" Nom.
Compliances:
•ꢀNECꢀArticleꢀ725ꢀTypeꢀCL2
•ꢀNECꢀArticleꢀ800ꢀTypeꢀCM
ꢀ
ꢀ
NOTE:ꢀGeneralꢀCableꢀmanufacturesꢀtheꢀaboveꢀcablesꢀinꢀaꢀwideꢀrangeꢀofꢀalternateꢀAWGꢀsizes,ꢀpairꢀcountsꢀandꢀjacketꢀcolors.
Please consult Customer Service for details.
Packaging and Jacket Colors:
ꢀ
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
packaging and color options
167
Electronics
Audio/Video & Home Entertainment Cable
Analog Audio Snake Cable
70 Ohm Low Capacitance Multi-Pair Individually Shielded
,
NEC Type CM/CL2
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀstrandedꢀtinnedꢀcopper
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
•ꢀꢀPolyolefin
ꢀ
CATALOG
NUMBER
CONDUCTOR
INSULATION
& O.D.
SHIELD
(COV.)
JACKET
& O.D.
WT. IMPED. CAPAC.
#/m OHMS pF/ft
Shield:
ꢀ
ꢀ
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀwithꢀ24ꢀAWGꢀ
drain wire
•ꢀꢀOverallꢀfoilꢀshieldꢀ24ꢀAWGꢀdrainꢀwire
1/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Polyolefin
FR-PVC Matte
11
39
65
65
65
65
65
65
65
65
65
65
65
24
24
24
24
24
24
24
24
24
24
24
740701
740704
740706
740708
740709
740712
740716
740720
740728
740742
740752
0.044" Nom.
Finish 0.137” Nom.
Overall Foil w/ 18 AWG Drain
4/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
Jacket:
•ꢀꢀPVC,ꢀmatteꢀblack
•ꢀꢀHigh-flex,ꢀflame-retardant
Polyolefin
0.044" Nom.
FR-PVC Matte
Finish 0.280” Nom.
ꢀ
ꢀ
6/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
Polyolefin
0.044" Nom.
FR-PVC Matte
Finish 0.330” Nom.
55
Applications:
ꢀ
ꢀ
8/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
•ꢀꢀLineꢀlevelꢀmicrophone
Polyolefin
0.044" Nom.
FR-PVC Matte
Finish 0.350” Nom.
69
•ꢀꢀInterconnectionꢀandꢀaudioꢀcomponentsꢀ
for console board equipment used in
recording studios, radio and television
stations, and post-production facilities
9/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
Polyolefin
0.044" Nom.
FR-PVC Matte
Finish 0.380” Nom.
76
12/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
ꢀ
•ꢀꢀSoundꢀsystemꢀinstallations
Polyolefin
0.044" Nom.
FR-PVC Matte
Finish 0.425” Nom.
96
Features:
ꢀ
16/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
•ꢀꢀPVCꢀjacketingꢀcompoundꢀforꢀsuperiorꢀ
cosmetics, durability and flexibility
•ꢀꢀIndividuallyꢀshieldedꢀpairsꢀareꢀcolor-
coded for easy identification
Polyolefin
0.044" Nom.
FR-PVC Matte
Finish 0.490” Nom.
130
158
221
327
391
ꢀ
20/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
Polyolefin
0.044" Nom.
FR-PVC Matte
Finish 0.540” Nom.
Compliances:
ꢀ
ꢀ
28/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
Polyolefin
0.044" Nom.
FR-PVC Matte
Finish 0.655” Nom.
•ꢀNECꢀArticleꢀ725ꢀTypeꢀCL2
•ꢀNECꢀArticleꢀ800ꢀTypeꢀCM
42/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
Polyolefin
0.044" Nom.
FR-PVC Matte
Finish 0.775” Nom.
Packaging and Jacket Colors:
ꢀ
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
packaging and color options
52/PR 24 AWG
Stranded 7/32 Tinned
Copper
Overall Foil w/
24 AWG Drain
Overall Foil w/ 18 AWG Drain
Polyolefin
0.044" Nom.
FR-PVC Matte
Finish 0.845” Nom.
NOTE:ꢀGeneralꢀCableꢀmanufacturesꢀtheꢀaboveꢀcablesꢀinꢀaꢀwideꢀrangeꢀofꢀalternateꢀAWGꢀsizes,ꢀpairꢀcountsꢀandꢀjacketꢀcolors.
Please consult Customer Service for details.
168
Audio/Video & Home Entertainment Cable
Electronics
Guitar/Instrument Cable
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20ꢀorꢀ24ꢀAWGꢀstrandedꢀbareꢀcopper
Insulation:
•ꢀꢀDualꢀlayerꢀofꢀsemi-conductiveꢀPVCꢀoverꢀ
ꢀ
polyethylene
Shield:
CATALOG
NUMBER
INSULATION
& O.D.
SHIELD
(COV.)
JACKET
& O.D.
WT. IMPED. CAPAC.
#/m OHMS pF/ft.
ꢀ
•ꢀꢀ36ꢀAWGꢀbareꢀcopperꢀbraidꢀorꢀspiral
CONDUCTOR
Jacket:
0.038" Poly
0.010" Semi
Conductive
Vinyl
1/C 20 AWG
Stranded 41/36
Bare Copper
“HQA” PVC
0.240
36ꢀAWGꢀ95%ꢀNom.
ꢀ
ꢀ
•ꢀꢀHighꢀqualityꢀaudioꢀ(HQA)ꢀPVC,ꢀmatteꢀ
34
34
34
36
30
47
47
47
47
47
33
33
33
33
33
743601
743602
743603
743604
743605
Bare Copper Braid
black
•ꢀꢀSuperiorꢀflexibility
Nom. Black
0.038" Poly
0.010" Semi
Conductive
Vinyl
1/C 20 AWG
Stranded 41/36
Bare Copper
“HQA” PVC
0.240
Nom. Black
Applications:
•ꢀꢀGuitars
•ꢀꢀBasses
•ꢀꢀKeyboardsꢀandꢀotherꢀinstrumentsꢀtoꢀ
amplifiers, mixers and effects pedals
•ꢀꢀAllꢀoutdoorꢀsignalꢀprocessingꢀgear
36ꢀAWGꢀ65%ꢀNom.
Bare Copper Spiral
ꢀ
ꢀ
ꢀ
0.038" Poly
0.010" Semi
Conductive
Vinyl
1/C 20 AWG
Stranded 41/36
Bare Copper
“HQA” PVC
0.240
Nom. Black
36ꢀAWGꢀ95%ꢀNom.
Bare Copper Braid
ꢀ
0.025" Poly
0.010" Semi
Conductive
Vinyl
Features:
•ꢀꢀLowꢀcapacitanceꢀtoꢀprovideꢀexcellentꢀ
structural return loss characteristics
•ꢀꢀSpeciallyꢀformulatedꢀvinylꢀsleevingꢀ
reduces triboelectric charges which
cause microphonic handling noise in
high-gain amplification applications
1/C 20 AWG
Stranded 22/34
Bare Copper
“HQA” PVC
0.235
Nom. Black
36ꢀAWGꢀ65%ꢀNom.
Bare Copper Spiral
ꢀ
ꢀ
0.040" Poly
0.010" Semi
Conductive
Vinyl
1/C 24 AWG
Stranded 7/32
Bare Copper
“HQA” PVC
0.235
Nom. Black
36ꢀAWGꢀ95%ꢀNom.
Bare Copper Spiral
Packaging and Jacket Colors:
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
ꢀ
packaging and color options
169
Electronics
Audio/Video & Home Entertainment Cable
Ultra Flexible, Low Impedance 2-Conductor Microphone Cable
Product Construction:
Conductor:
ꢀ
•ꢀꢀ20-24ꢀAWGꢀstrandedꢀbareꢀcopper
ꢀ
•ꢀꢀTwistedꢀpairs
Insulation:
ꢀ
ꢀ
•ꢀꢀPVCꢀorꢀpolyethylene
Shield:
CATALOG
NUMBER
INSULATION
& O.D.
SHIELD
(COV.)
JACKET
& O.D.
WT. IMPED. CAPAC.
#/m OHMS pF/ft
CONDUCTOR
•ꢀꢀBraidꢀorꢀspiral,ꢀbareꢀorꢀtinnedꢀcopperꢀ
(choiceꢀofꢀshieldingꢀconfigurations)
2/C 24 AWG Stranded
PVC
80%ꢀNom.ꢀBare “HQA” PVC 0.176" 22
Nom. Black
65
80
80
85
80
30
20
20
18
20
743701
743704
743705
743706
743707
Jacket:
105/44 Bare Copper 0.045" Nom. Copper Braid
ꢀ
ꢀ
•ꢀꢀHighꢀqualityꢀaudioꢀ(HQA)ꢀPVC,ꢀmatteꢀ
2/C 24 AWG Stranded Polyethylene 95%ꢀTinned “HQA” PVC 0.194" 23
41/40 Bare Copper
black
•ꢀꢀSuperiorꢀflexibility
0.050" Nom. Copper Braid
Nom. Black
2/C 24 AWG Stranded Polyethylene
16/36 Bare Copper 0.050" Nom. Copper Spiral
95%ꢀBare
“HQA” PVC 0.225" 29
Nom. Black
Applications:
•ꢀꢀGeneral-purposeꢀaudioꢀapplications
•ꢀꢀHomeꢀentertainment
•ꢀꢀMusicalꢀinstruments
ꢀ
ꢀ
ꢀ
2/C 22 AWG Stranded Polyethylene
26/36 Bare Copper 0.062" Nom. Copper Braid
85%ꢀBare
“HQA” PVC 0.232" 34
Nom. Black
2/C 20 AWG Stranded Polyethylene
41/36 Bare Copper 0.074" Nom. Copper Braid
85%ꢀBare
“HQA” PVC 0.262" 40
Nom. Black
Features:
•ꢀꢀTwistedꢀconductorꢀconstructionꢀ
minimizes effects of EMI
•ꢀꢀPreciseꢀapplicationꢀofꢀfillerꢀmaintainsꢀ
mechanical durability to resist annoying
handling noise
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀBraidꢀshieldꢀguardsꢀagainstꢀcrosstalkꢀ
and EMI while minimizing capacitive
reactance, which causes hum and buzz
•ꢀꢀHighꢀstrandꢀconductorꢀplusꢀHQAꢀjacketꢀ
results in ultimate flexibility
Packaging and Jacket Colors:
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
ꢀ
packaging and color options
170
Audio/Video & Home Entertainment Cable
Electronics
Multi-Conductor, Flexfoil® Shield
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
polypropylene
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
NOMINAL O.D.
STRAND INCHES mm INCHES mm INCHES mm
pF/ft
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
A
B
Shield:
ꢀ
ꢀ
•ꢀꢀConductiveꢀtapeꢀappliedꢀoverꢀtheꢀcore
2
24
19/36
0.008 0.20 0.022 0.56 0.135 3.43 27.0 48.5
C1228A
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester,
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
25%ꢀoverlap,ꢀminimum,ꢀfoilꢀfacingꢀin
ꢀ
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀblack
Color Code Chart
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
NO. OF
COND.
COLOR
Black
Red
Applications:
•ꢀꢀElectronicꢀcircuitsꢀwhereꢀRFꢀshieldingꢀisꢀ
1
2
ꢀ
required
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀRadioꢀtransmitters
•ꢀꢀSoundꢀsystems
•ꢀꢀRecordingꢀstudios
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Features:
ꢀ
•ꢀꢀExcellentꢀshieldingꢀtoꢀreduceꢀnoise
Compliances:
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
171
Electronics
Audio/Video & Home Entertainment Cable
Multi-Conductor, Rubber, Braid Shield Microphone Cable
High and Low Impedance
Product Construction:
Conductor:
ꢀ
•ꢀꢀ18ꢀandꢀ20ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀrubberꢀ
insulation
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
STRAND INCHES mm INCHES mm INCHES mm
NOM. CAP.*
pF/ft
Shield:
ꢀ
ꢀ
ꢀ
•ꢀCꢀ learꢀMylar® wrap
•ꢀꢀ80%ꢀtinnedꢀcopperꢀbraid
•ꢀꢀCottonꢀwrap
1
1
2
20
18
20
26/34
41/34
26/34
0.042 1.07 0.035 0.89 0.230 5.84
0.040 1.02 0.035 0.89 0.240 6.10
0.020 0.51 0.035 0.89 0.270 6.86
42.0
46.0
50.0
C1300
C1301
C1302
Jacket:
*Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
•ꢀꢀRubber,ꢀblack
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+60°C
Applications:
C1300, C1301:
Color Code Chart
NO. OF
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀHigh-impedanceꢀmicrophones
COND.
COLOR
White
Black
•ꢀꢀBroadcastꢀandꢀstudioꢀuse
•ꢀꢀCommunicationꢀandꢀaudioꢀsystem
•ꢀꢀShieldedꢀpowerꢀsupplies
1
2
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
C1302:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀLow-impedanceꢀmicrophones
•ꢀꢀStudioꢀuse
•ꢀꢀControlꢀcircuits
•ꢀꢀVideoꢀandꢀaudioꢀinterconnectingꢀcables
•ꢀꢀShieldedꢀpowerꢀsupplies
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Features:
ꢀ
•ꢀꢀPrecisionꢀengineeredꢀtoꢀtransmitꢀclear,ꢀ
noise-free signals
ꢀ
ꢀ
•ꢀꢀMinimizesꢀelectricalꢀ“hum”
•ꢀꢀBraidꢀshieldꢀprovidesꢀextraꢀflexibility
Compliances:
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
172
Audio/Video & Home Entertainment Cable
Electronics
Multi-Conductor, Spiral Shield
Product Construction:
Conductor:
ꢀ
•ꢀꢀ24ꢀAWGꢀannealedꢀstrandedꢀbareꢀcopperꢀ
per ASTM B-3
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀPVC
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOM. CAP.*
NOMINAL O.D.
STRAND INCHES mm INCHES mm INCHES mm
pF/ft
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
Shield:
•ꢀꢀ85%ꢀspiral-tinnedꢀcopper
A
B
ꢀ
Jacket:
2
24
105/44
0.012 0.30 0.030 0.76 0.176 4.47 43.0 77.0
C1226A
ꢀ
ꢀ
•ꢀꢀPVC,ꢀblack
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+90°C
Applications:
ꢀ
•ꢀꢀElectronicꢀcircuitsꢀwhereꢀRFꢀshieldingꢀisꢀ
required
Color Code Chart
NO. OF
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀRadioꢀtransmitters
•ꢀꢀSoundꢀsystems
•ꢀꢀRecordingꢀstudios
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
COND.
COLOR
White
Green
1
2
Features:
ꢀ
•ꢀꢀSpiralꢀshieldꢀprovidesꢀextraꢀflexibility
ꢀ
•ꢀꢀExcellentꢀshieldingꢀtoꢀreduceꢀnoise
Compliances:
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
173
Electronics
Audio/Video & Home Entertainment Cable
Multi-Conductor, Braid Shield
Low Impedance
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀfullyꢀannealedꢀstrandedꢀtinnedꢀ
copper per ASTM B-33
Insulation:
•ꢀꢀPremium-grade,ꢀcoIor-codedꢀ
ꢀ
polyethylene
•ꢀꢀFillersꢀwhereꢀrequired
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS
THICKNESS NOMINAL O.D.
ꢀ
ꢀ
CATALOG
NO. OF AWG COND.
NOM. CAP.*
pF/ft
NUMBER TYPE COND. SIZE STRAND INCHES mm INCHES mm INCHES mm
Shield:
•ꢀꢀ80%ꢀtinnedꢀcopperꢀbraid
Low
Imped.
2
22
16/34 0.025 0.64 0.025 0.64 0.239 6.07
31.0
C1322A
ꢀ
*Capacitance between one conductor and other conductors connected to shield
Jacket:
ꢀ
ꢀ
•ꢀꢀPVC,ꢀgray
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
Color Code Chart
Applications:
ꢀ
ꢀ
NO. OF
•ꢀꢀLow-impedanceꢀmicrophones
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ1000ꢀvolts
COND.
COLOR
White
Black
1
2
Features:
ꢀ
•ꢀFꢀ lexlife® jacket provides extreme
flexibility
ꢀ
ꢀ
•ꢀꢀHighꢀabrasionꢀresistance
•ꢀꢀOutstandingꢀappearance
Compliances:
ꢀ
•ꢀꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
174
Audio/Video & Home Entertainment Cable
Electronics
Microphone Cable, Multi-Conductor, Carolprene®,
Braid Shield High and Low Impedance
Product Construction:
Conductor:
•ꢀꢀ18ꢀandꢀ16ꢀAWGꢀfullyꢀannealedꢀstrandedꢀ
ꢀ
tinned copper per ASTM B-33
Insulation:
ꢀ
ꢀ
•ꢀꢀPremium-grade,ꢀcolor-codedꢀrubber
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
NOM. INSULATION NOM. JACKET
THICKNESS THICKNESS
NOMINAL O.D.
CATALOG NO. OF AWG
NUMBER COND. SIZE
COND.
STRAND INCHES mm INCHES mm INCHES mm
NOM. CAP.*
pF/ft
Shield:
ꢀ
ꢀ
ꢀ
•ꢀCꢀ learꢀMylar® wrap
•ꢀꢀ80%ꢀbraidꢀtinnedꢀcopper
•ꢀꢀCottonꢀwrap
1
2
2
18
18
16
41/34
41/34
65/34
0.040 1.02 0.035 0.89 0.240 6.10
0.020 0.51 0.035 0.89 0.295 7.49
0.025 0.64 0.035 0.89 0.335 8.51
46.0
61.0
55.0
C1201
C1202
C1602
Jacket:
ꢀ
ꢀ
•ꢀꢀCarolprene®, black
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+60°C
*Capacitance between one conductor and other conductors connected to shield
Applications:
C1201:
Color Code Chart
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀHigh-impedanceꢀmicrophones
NO. OF
•ꢀꢀBroadcastꢀandꢀstudioꢀuse
•ꢀꢀCommunicationꢀandꢀaudioꢀsystems
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
COND.
COLOR
White
Black
1
2
C1202, C1602:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀꢀLow-impedanceꢀmicrophones
•ꢀꢀStudioꢀuse
•ꢀꢀControlꢀcircuits
•ꢀꢀVideoꢀandꢀinterconnectingꢀcables
•ꢀꢀShieldedꢀpowerꢀsupplies
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
Features:
ꢀ
•ꢀꢀPrecisionꢀengineeredꢀtoꢀtransmitꢀclear,ꢀ
noise-free signals
ꢀ
ꢀ
•ꢀꢀMinimizesꢀelectricalꢀ“hum”
•ꢀꢀResistantꢀtoꢀoil,ꢀacid,ꢀsunlight,ꢀabrasionꢀ
and aging
ꢀ
•ꢀꢀExcellentꢀnoiseꢀrejection
Compliances:
ꢀ
•ꢀRoHSꢀCompliantꢀDirectiveꢀ2002/95/EC
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
175
Electronics
Audio/Video & Home Entertainment Cable
SMPTE-311 Hybrid Fiber Optic/Copper Camera Cable
Product Construction:
Conductor:
ꢀ
ꢀ
ꢀ
•ꢀElementꢀ#1:ꢀ 4 auxiliary conductors
(usedꢀasꢀtwo)
ꢀ Size:ꢀ
20 AWG; stranded tinned
annealed copper
High-density polyethylene
O.D.:ꢀ0.060"ꢀnom.ꢀ
(1.53mm)
ꢀ Insulation:ꢀ
CATALOG
NUMBER
AUXILIARY
CONDUCTOR
OPTICAL
FIBER
STRENGTH
MEMBER
SIGNAL COND.
SHIELD
JACKET
ꢀ
ꢀ
•ꢀElementꢀ#2:ꢀ 2 single conductors
(4)ꢀ20ꢀAWGꢀ26/34 (2)ꢀ25ꢀAWGꢀ7/33ꢀ (2)ꢀ9.5ꢀMicron 14 AWG 19/27 95%ꢀBraid Flexible PVC
742608
ꢀ Size:ꢀ
24 AWG; stranded tinned
annealed copper
Strand Tinned Cu Strand Tinned Cu Single-Mode
Strand
Tinned CU
(HQA)
High-density
Polyethylene
High-density
Polyethylene
Galvanized Steel
Black 0.362"
O.D. 9.20 mm
ꢀ
ꢀ Insulation:ꢀ
High-densityꢀpolyethylene:ꢀ
0.045"ꢀnom.ꢀ(1.12mm)
Insul. O.D. 0.060" Insul. O.D. 0.045"
(4)ꢀ20ꢀAWGꢀ26/34 (2)ꢀ25ꢀAWGꢀ7/33ꢀ (2)ꢀ9.5ꢀMicron 14 AWG 19/27 95%ꢀBraid Ruggedized
574608
ꢀ
•ꢀElementꢀ#3:ꢀ Singlemodeꢀfiberꢀoptic
Strand Tinned Cu Strand Tinned Cu Single-Mode
Strand
Tinned CU Outdoor TPR
Black 0.362"
High-density
Polyethylene
High-density
Polyethylene
Galvanized Steel
ꢀ
ꢀ
•ꢀElementꢀ#4:ꢀ Strength member in core
O.D. 9.20 mm
ꢀ Size:ꢀ
16 AWG; stranded
insulated galvanized steel
cable
Insul. O.D. 0.060" Insul. O.D. 0.045"
NOTE:ꢀGeneralꢀCableꢀmanufacturesꢀtheꢀaboveꢀcablesꢀinꢀaꢀwideꢀrangeꢀofꢀalternateꢀAWGꢀsizes,ꢀpairꢀcountsꢀandꢀjacketꢀcolors.
Please consult Customer Service for details.
ꢀ
ꢀ
ꢀ Color:ꢀ
ꢀ O.D.:ꢀ
White
0.083"ꢀnom.ꢀ(2.1mm)
Fillers:
Cable Characteristics
ꢀ
•ꢀꢀFibrillatedꢀpolypropyleneꢀasꢀneededꢀforꢀ
roundness
ELEMENT NUMBER (1) AUXILIARY CONDUCTORS (2) SIGNAL CONDUCTORS
(3) SINGLEMODE FIBER OPTIC
Mode Field Data 9.5+/-1ꢀMicron
Cladding Data 125+/-1ꢀMicron
Buffer Material Thermoplastic
Binder:
ꢀ
ꢀ
•ꢀꢀPaperꢀtapeꢀwithꢀ25%ꢀoverlap
CONDUCTOR
35.29Ω/Kmꢀmaxꢀ@20˚C
43Ω/Kmꢀmaxꢀ@20˚C
97.5ΩKmꢀmaxꢀ@20˚C
184ΩKmꢀmaxꢀ@20˚C
DCR
Braid Shield:
•ꢀꢀFlexiblyꢀdesignedꢀbraidꢀshieldꢀwithꢀ85%
nom. coverage
DC LOOP
RESISTANCE
INSULATION
RESISTANCE
10,000Ω/Kmꢀmaxꢀ@20˚C 10,000ΩKmꢀmaxꢀ@20˚C
Jacket:
•ꢀꢀFlexibleꢀPVCꢀ(HQA)
•ꢀꢀTemperatureꢀrange:ꢀ-40˚Cꢀtoꢀ+75˚C
•ꢀꢀHumidityꢀ0ꢀtoꢀ95%
•ꢀꢀTPRꢀruggedizedꢀoutdoorꢀversion
DIELECTRIC
STRENGTH
1750VꢀRMS@20˚C,
60Hz for 1 min
1750VꢀRMS@20˚C,
60Hz for 1 min
ꢀ
ꢀ
ꢀ
ꢀ
VOLTAGE
RATING
300V Max
300V Max
C1, C3-Black
C2, C4-White
C1-Red
C2-Gray
C1-Blue
C2-Yellow
COLOR
Jacket Marking:
ꢀ
•ꢀꢀHELIX/HITEMPꢀP/NꢀXXXXXX*ꢀSINGLE-
MODE FIBER OPTIC/ELECTRICAL HD
CAMERAꢀCABLEꢀ(RU)ꢀAWMꢀSTYLEꢀ
21059 80C 300V VW-1
TYPICAL CROSS SECTION
Jacket
Cable Weight:
ꢀ
•ꢀꢀ87.6ꢀlbs/Mftꢀnom.ꢀ(130.8Kg/KM)
Shield
Performance:
4/Auxiliary Cond
ꢀ
•ꢀꢀMeets/exceedsꢀSMPTE-311ꢀM-1998
Connector:
•ꢀꢀLEMOꢀconnectorꢀ(callꢀLEMOꢀforꢀmoreꢀ
informationꢀatꢀ800.444.5366)
2/Optical Fibers
ꢀ
Strength Member
ꢀ
•ꢀꢀSMPTEꢀstandardꢀ304ꢀvideoꢀconnector
Compliances:
ꢀ
ꢀ
•ꢀꢀULꢀSubjectꢀ758
•ꢀꢀAWMꢀStyleꢀ21059
2/Signal Cond
Packaging:
ꢀ
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
packaging and color options
*XXXXXXꢀ-ꢀindicatesꢀpartꢀnumber
176
Audio/Video & Home Entertainment Cable
Electronics
Electronic News Gathering/Field Production Camera Cable
Product Construction:
Applications:
ꢀ
•ꢀꢀIdealꢀforꢀTVꢀbroadcastꢀandꢀCCTVꢀ
applications
ꢀ
•ꢀꢀSuitedꢀforꢀcontrolling,ꢀpoweringꢀandꢀ
transmitting audio and video signals for
TV cameras
CATALOG
NUMBER
COAXIAL
COMPONENT
ꢀ
•ꢀꢀAdditionalꢀusesꢀincludeꢀremoteꢀcontrol,ꢀ
monitor and cue line systems
SIGNAL PAIR
POWER PAIR
JACKET
Features:
1/C 25 AWG Stranded 7/33
Bare Copper
1/PR 24 AWG
1/PR 22 AWG
Matte Black
742605
Stranded 19/36 Bare Stranded 26/36 Bare "HQA" PVC
ꢀ
ꢀ
•ꢀꢀProvidesꢀexcellentꢀcircuitꢀisolation
High-density Polyethylene Insulation
90%ꢀBareꢀCopperꢀBraid
PVCꢀJacket
Copper
Polyethylene
Insulationꢀ+ꢀFoil
24 AWG Drain
O.D. 0.140" Nom.
Copper
PVC Insulation
O.D. 0.100" Nom.
O.D. .495"
Nom.
•ꢀꢀSuperiorꢀdurabilityꢀcharacteristicsꢀinꢀaꢀ
variety of environmental conditions
O.D. 0.175" Nom.
Packaging and Jacket Colors:
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
ꢀ
NOTE:ꢀGeneralꢀCableꢀmanufacturesꢀtheꢀaboveꢀcablesꢀinꢀaꢀwideꢀrangeꢀofꢀalternateꢀAWGꢀsizes,ꢀpairꢀcountsꢀandꢀjacketꢀcolors.
Please consult Customer Service for details.
177
Electronics
Specialty Cable
9
Index
Page
Armored Electronics
Products Guide
179-180
181
Wind Energy
Fluorobus Cable
Fire Wire
General Cable has a variety
of wire and cable available
for special applications. This
section includes an array of
For more information on these
cables or for other special
applications, please contact
your General Cable sales
182
183
products from our Fluorobus flat representative.
bus ground/power distribution
cable to high-speed serial
Computer Cable
184
interface cable, known as Fire
Wire, and computer cables.
Composite Data and
Control Cable
185
178
E L E C T R O N I C S P R O D U C T B U L L E T I N
Armored
Electronics Products
General Cable now offers the
capability to armor virtually any
Carol® Brand Electronics cable.
This rugged exterior and protection
allows for the installation of almost
any Electronics cable in markets
with the toughest and most rigorous
building code requirements. Cables
placed in armor are not only acceptable
for use in Riser applications, but
according to NEC Article 300.22(B),
these cables are acceptable in Plenum
applications as well.
The process to convert a standard
Carol Brand Electronics cable to
an armored cable is simple and
is explained on the back of this
bulletin. All you really need to know is:
1) which cable you want to armor,
2) whether you want steel or aluminum
interlock armor, and 3) what put-up
lengths you would like to receive
product on.
General Cable continues to expand
its Carol Brand Electronics product
offering to allow our customers
to participate in more diversified
markets. You can always Demand
Better...Expect More™ with General
Cable Carol Brand Electronics cables.
We manufacture over 1,300 standard
electronic cables that we ship direct
from stock, and we have the technical
staff and design expertise to meet any
customer cable requirement.
Special Application Cable
Hook-Up Wire
Plenum Cable
Coaxial Cable
Microphone Cable
Computer Cable
General Purpose Cable
Multi-Conductor Communication
& Control Cable
Multi-Paired Communication
& Control Cable
Fire Alarm Cable
Sound & Security Cable
179
Armored Electronics Products
HOWTO ARMORYOUR ELECTRONICS
Step 1 - Find a Carol Brand part # in the catalog that you want to armor.
Step 2 - Build your Carol Brand Armored part #
Carol® Brand Communication & Control Cable,
Multi-Conductor, Unshielded
❶ Pick the root part # you want to armor.
❷ Pick the put-up length that you want.
❸ Pick the color of jacket for the wire.
❹ Pick the type of armor you want.
ꢀ
ꢀ
ꢀ
NOM. INSULATION
THICKNESS
NOMINAL JACKET
THICKNESS
NOMINAL O.D.
CATALOG
NUMBER
NO. OF
COND.
COND.
STRAND.
NOM. C-C
CAP. pF/FT
AWG SIZE
INCHES
mm
INCHES
mm
INCHES
mm
2
14
19/.0147
0.030
0.81
0.032
0.81
0.260
6.81
30.5
C2409A
❶
❷
❸
❹
C2409A
41
02
Cable
Jacket Color
A
Root #
Put-Up
Armor
Indicator
Armored Part # looks like: C2409A.41.02A
Description is now: 14 AWG / 2 Conductor, Unshielded, White Jacket Communication Cable in Aluminum Armor on a 1000' Reel.
Armor Codes & Charts
Armor Sizing Chart
Wire Jacket Color
Armor Codes
CABLE DIAMETER
ARMOR STRIP WIDTH
CLEARANCE (IN)
ARMOR O.D. (IN)
ARMOR WEIGHT (LBS/mFT)
CODE
COLOR
TYPE
CODE
0.190
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
0.060
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.350
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
29.000
38.600
43.400
48.300
53.100
57.900
01
02
03
04
05
06
07
08
09
10
11
BLACK
WHITE
Aluminum
Steel
A
S
RED
ORANGE
YELLOW
GREEN
Put-Up Codes
SIZE
CODE
62.700
67.600
DARK BLUE
BROWN
MAROON
GRAY
250
'
35
38
41
500
'
72.400
77.200
1000'
NOTE 1: Consult factory for
additional put-up lengths
NOTE 2: Product provided on reels
109.400
115.800
122.300
ANTIQUE GOLD
IVORY
12
13
PINK
NOTE: Additional colors available
Products in the Electronics Catalog that can be armored:
Section 2 - Communication & Control Cable, Multi-Conductor
Section 3 - Communication & Control Cable, Multi-Paired
Section 4 - Computer Cable
Section 6 - Fire Alarm / Life Safety Cable
Section 7 - Sound, Alarm, & Security
Section 8 - Audio / Home Entertainment Cable
Section 5 - Coaxial Cable
180
Delivering the renewable power of
Wind Energy
Wind knows no boundaries,
and neither does General Cable.
Answering the Call
Wind. It’s plentiful, renewable, and clean. That’s why wind
power has increased more than fivefold since the beginning
of the 21st century, taking center stage as the fastest growing
alternative energy source in the global arena. With increased
energy demand and mounting political pressure, alternative
energy mandates are cropping up all over the world,
with many countries calling for significant growth in wind
generation capacity over the next decade. General Cable
has the experience, the innovation, and the global presence
to answer that call.
Since the first modern wind turbine was developed in the
1980s, General Cable has been committed to delivering the
renewable power of wind energy through ground-breaking
One Company approach means we have a keen ability
to unite and leverage our broad knowledge and shared
resources to bring innovative solutions to the entire world.
wire and cable technologies. General Cable has developed
cables that are flexible yet tough enough to withstand the
continuous motion of today’s wind turbines. Our commitment
to providing the highest quality and reliable products lowers
cost and extends turbine operating life by reducing failures
and maintaining continuous power.
Setting the Benchmark
Whether it is terrestrial wind farms requiring direct buried
cables or offshore wind farms requiring high-performance
submarine cables, General Cable has one of the most diverse
and expansive ranges of products to meet virtually every
application in the wind power industry. From fiber optic and
bare overhead conductors to underground URD and low-
voltage power, control, and electronic cables, General Cable
offers the full array of cables needed for wind turbines to
generate, distribute, and transmit energy.
Knowing No Boundaries
Wind knows no boundaries, and neither does General Cable.
From Brazil, Mexico, and the U.S. to Germany, Spain, China,
India, and Australia, initiatives are in place to increase
wind power, with targets to support a significantly higher
percentage of energy needs.
With a solid presence in North America, South America,
Europe, Asia, Africa, the Middle East, and Oceania, General
Cable has the geographical presence to focus on region-
specific wind power needs and to meet domestic and
global specifications. At the same time, General Cable’s
As the benchmark in the wire and cable industry, renowned
for our engineering and material development capabilities,
General Cable is positioned to rapidly respond to the needs
of the evolving wind farm market with next-generation
cabling systems.
Call us today at 888.593.3355 for additional information.
181
Electronics
Specialty Cable
Fluorobus Cable
Flat Bus Ground / Power Distribution Cable
Applications:
ꢀ
CATALOG
NUMBER
CONDUCTOR INSULATION
FINISHED
DIMENSIONS
DCR
POWER RATING
•ꢀꢀIdeallyꢀsuitedꢀforꢀlow-voltageꢀprimaryꢀ
and secondary power distribution
in electronic and data processing
equipment. High-speed, solid-state
circuits require relatively high currents
with low voltage. For this reason, it is
essential that DC power distribution lines
have low inductance, low resistance
and high capacitance. More important,
tightly bundled or laminated flat cable
source-and-return circuits deliver lower
impedance and higher capacitance
by one to two orders of magnitude,
compared to round wire circuits with
equal resistance.
Flat Solid BC
Tetzel®
0.010" x 0.987" (ETFE)
0.82 Ohms per 32 Amps Nom.
1000 ft. @ 25˚C 100 Amps Max.
0.028 x 1.022
0.037 x 1.022
SP00C0011010
SP00C0012010
Flat Solid BC
Tetzel®
0.020" x 0.987" (ETFE)
0.41 Ohms per 64ꢀAmpsꢀNom.
1000 ft. @ 25˚C 100 Amps Max.
Informationꢀisꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
ꢀ
ꢀ
•ꢀꢀThisꢀsystemꢀcanꢀserveꢀasꢀaꢀlow-costꢀ
flexible alternative to laminated bus
bars. The Fluorobus low-profile routing
capability is a useful packaging feature,
and its large surface area (relative
to round wire conductor of equal
resistance) provides improved heat
dissipation, minimizes voltage drop and
results in a higher current rating.
•ꢀꢀThisꢀflatꢀconductorꢀcircuitꢀdeliversꢀ
superiorꢀEMI/RFIꢀperformance,ꢀbothꢀ
as a source and as a receiver.
Features
Low Profile:
Flexible:
Benefits
Conserves space
Ease of routing
Large Surface Improvedꢀheatꢀdissipationꢀ
Area:
minimizes voltage drop
High current rating
Temperature Rating:
ꢀ
•ꢀꢀ-50°Cꢀtoꢀ+150°C
Voltage Rating:
ꢀ
•ꢀꢀ300ꢀvoltsꢀandꢀ600ꢀvoltsꢀ(AWM)ꢀavailableꢀꢀ
(consult Customer Service)
Dielectric Constant:
ꢀ
•ꢀꢀ2.6
Dielectric Strength:
ꢀ
•ꢀꢀ900ꢀVRMS
Packaging and Color:
ꢀ
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
packaging and color options
182
Specialty Cable
Electronics
Fire Wire*
IEEEꢀ1394ꢀHigh-SpeedꢀSerialꢀInterface
Applications:
ꢀ
•ꢀꢀTransportꢀdigitalꢀdataꢀforꢀcomputersꢀandꢀ
for professional and consumer electronic
products
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀPersonalꢀcomputers
•ꢀꢀAudio/image/videoꢀproducts
•ꢀꢀPrinters/scanners
•ꢀꢀDiscꢀarrays
•ꢀꢀDigitalꢀvideoꢀcameras/displays/recorders
CATALOG NUMBER
Z028C0061110
SIGNAL SIGNAL
PR. PR.
JACKET IMPED. CAPAC. MHz
ATTENUATION
NOM.
SIGNAL PAIRS
POWER
OVERALL
OVERALL
Compliances:
CONDUCTOR SHIELDING
DB 100'
ꢀ
ꢀ
ꢀ
•ꢀꢀUL:ꢀAWMꢀ20276
•ꢀꢀ80˚Cꢀ30VꢀVW-1
•ꢀCSA:ꢀPCCꢀFT1
2/C #22
7/36ꢀTC
2/C #22
7/36ꢀTC
Aluminum/ Flexible
110
12.5 1000.0 37
55
Mylar®
(Foil Out)
PVC
Ohms pF/ft
Packaging and Jacket Colors:
ꢀ
Foam Poly
Insulation
Individualꢀ
Foil & Braid
Polyolefin +ꢀ95%ꢀBraid
Insulation
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
packaging and color options
Black, White
No.ꢀ1:ꢀRed,ꢀGreen
No. 2: Blue, Orange
* Apple Computer trademark
183
Electronics
Specialty Cable
Computer Cable
Mainframes, Data Transfer, Tape Drives, File Servers, Disc Drives, Workstations,
Disc Arrays, Personal Computers, etc.
Applications:
PART NUMBER
APPLICATION
DESCRIPTION
ꢀ
•ꢀꢀGeneralꢀCableꢀmanufacturesꢀaꢀdiverseꢀ
array of multiconductor cables for
computers and the interconnection
of their peripherals. Today’s need for
speed and signal capacity demands
the most in cable materials and
construction. Our state-of-the-art
manufacturing allows us to control
impedance, minimize signal skew
and provide the proper shielding for
applicationsꢀfromꢀUSBꢀandꢀFireꢀWireꢀ
right up through the latest Fiber Channel
protocols. Whether your applications
require parallel or serial signal
HIPPI
50 Pair, 28 AWG, 105 Ohm
EO28P0501510
EO24C0045510
EO26C0045510
EO28C0045510
EO30C0045510
EO28P0181510
Fiber Channel
Fiber Channel
Fiber Channel
Fiber Channel
IEEE-1284
2 Pair “Quad”, 24 AWG, 150 Ohm
2ꢀPairꢀ“Quad”,ꢀ26ꢀAWG,ꢀ150ꢀOhm
2 Pair “Quad”, 28 AWG, 150 Ohm
2 Pair “Quad”, 30 AWG, 150 Ohm
18ꢀPair,ꢀ28ꢀAWG,ꢀO/AꢀFoilꢀ+ꢀBraid
Testꢀ&ꢀMeasurement,ꢀDataꢀTransfer,ꢀElectronicꢀPublishing,ꢀVideoꢀConferencing,ꢀSoundꢀSynthesizers,ꢀPCꢀ
Workstations,ꢀMulti-Media,ꢀConsumerꢀElectronics,ꢀCableꢀTV,ꢀDigitalꢀCameras/Camcorders,ꢀetc.
PART NUMBER
APPLICATION
DESCRIPTION
IEEE-1394ꢀ(FireꢀWire)
2 Pair, 28 AWG, 2/C 22 AWG
Z028C0066110
transmission, General Cable has the
technology to fill your needs.
ISDN,ꢀCD-ROMꢀDrives,ꢀModems,ꢀScanners,ꢀPrinters,ꢀAudioꢀI/OꢀDevices,ꢀKeyboards,ꢀTelephoneꢀISDN,ꢀetc.
Packaging and Jacket Colors:
ꢀ
•ꢀꢀPleaseꢀconsultꢀCustomerꢀServiceꢀforꢀ
packaging and color options
PART NUMBER
APPLICATION
DESCRIPTION
UniversalꢀSerialꢀBus
UniversalꢀSerialꢀBus
UniversalꢀSerialꢀBus
UniversalꢀSerialꢀBus
UniversalꢀSerialꢀBus
1 Pair, 28 AWG, 2/C 20 AWG
1 Pair, 28 AWG, 2/C 22 AWG
1 Pair, 28 AWG, 2/C 24 AWG
1ꢀPair,ꢀ28ꢀAWG,ꢀ2/Cꢀ26ꢀAWG
1 Pair, 28 AWG, 2/C 28 AWG
ZO28C0042010
ZO28C0042210
ZO28C0042410
ZO28C0042610
ZO28C0042810
VideoꢀMonitors,ꢀCRTs,ꢀWorkstations
PART NUMBER
APPLICATION
Monitor 10/C
DESCRIPTION
ZO28C0101120
3/Coax 28 AWG, 7/C 28 AWG
184
Specialty Cable
Electronics
Composite Data and Control Cable
NECꢀTypeꢀCMPꢀ(UL)ꢀc(UL)
Product Construction:
Conductor:
ꢀ
•ꢀꢀ22ꢀAWGꢀandꢀ18ꢀAWGꢀfullyꢀannealedꢀ
stranded tinned copper per ASTM B-33
Insulation:
•ꢀꢀ22ꢀAWGꢀ-ꢀfoamꢀFEP
18ꢀAWGꢀ-ꢀplenumꢀPVC
ꢀ
ꢀ
NOM.
INSULATION
THICKNESS
NOM. JACKET
THICKNESS
NOMINAL CAP. *
pF/ft
NOMINAL O.D.
•ꢀꢀColorꢀcode:ꢀSeeꢀchartꢀbelow
CATALOG NO. OF AWG COND.
NUMBER PAIRS SIZE STRAND INCHES mm INCHES mm INCHES mm
22 AWG SHIELDED PAIR AND 18 AWG UNSHIELDED PAIR WITH OVERALL JACKET
1 each (22 7/30 TC 0.020 0.51) 0.015 0.381 0.195 4.95 13 (22) 35.0
A
B
Pair Shield (22 AWG):
ꢀ
ꢀ
•ꢀ1ꢀ 00%ꢀFlexfoil® aluminum/polyester foil
withꢀ25%ꢀoverlap,ꢀminimum
•ꢀꢀStrandedꢀtinnedꢀcopperꢀdrainꢀwire
C8125
(18 16/30ꢀTC 0.009 0.23)
30 (18)
Jacket:
*A - Capacitance between conductors
*B - Capacitance between one conductor and other conductors connected to shield
ꢀ
ꢀ
•ꢀꢀPlenumꢀPVC,ꢀnaturalꢀorꢀasꢀrequested
•ꢀꢀTemperatureꢀrange:ꢀ-20°Cꢀtoꢀ+75°C
Applications:
Color Code Chart
ꢀ
ꢀ
ꢀ
•ꢀꢀMultimediaꢀsystems
•ꢀꢀDataꢀandꢀcontrolꢀcircuits
•ꢀꢀSuggestedꢀvoltageꢀrating:ꢀ300ꢀvolts
AWG
22
COLOR
Blue & White
Blackꢀ&ꢀRed
Compliances:
18
ꢀ
•ꢀꢀNECꢀArticleꢀ800
ꢀ
•ꢀꢀDesignedꢀtoꢀmeetꢀNFPAꢀ262ꢀandꢀCSAꢀ
FT-6ꢀSteinerꢀTunnelꢀFireꢀTestsꢀforꢀPlenumꢀ
Applications
Features:
ꢀ
•ꢀꢀFire-retardant,ꢀlow-smokeꢀjacket
Packaging:
ꢀ
•ꢀꢀPleaseꢀcontactꢀCustomerꢀServiceꢀforꢀ
packaging and color options
185
Electronics
Technical Information
10
Index
Page
As technology becomes more
complex, specifying wire
and cable products to meet
system performance demands
becomes more time-consuming of hardware and transmission
and complex.
This technical section is
presented to aid in the selection
of materials and designs which
will best suit the combination
Insulation & Jacket
Properties
187
Decimal Conversion
Factors
188
189
media.
Unit Conversion Factors
Today’s system designer must
be aware not only of the general regarding specific transmission
transmission line types, but
also of the myriad of materials
available to meet specific
environmental or electrical
performance criteria.
For technical questions
Temperature Conversion
Chart
190
191
designs or applications, please
contact General Cable’s
Engineering Department.
Conduit Capacity
Chart
Coax Connector
Cross Reference
192-199
200
AWG Conductor Chart
Cable Design Equations—
Braid Shield
201
202
Coaxial Cable
Balanced Pair
Engineering Prefixes
Glossary
203
204
205-215
Abbreviations &
Acronyms
216-218
219
Product Finders—
Hook-Up Wire
Multi-Conductor
Cable
220-222
223-225
Multi-Paired Cable
NEC/CEC Substitution
Chart
226-227
228
Agency Symbols
Agency Approval Index
Put-Ups and Color Codes
Applications Index
229
230
231-233
Belden-to-General
Cable Carol® Brand
Cross Reference Index
234-239
240-246
247
Part Number Index
Notes
186
Technical Information
Electronics
Insulation & Jacket Properties
TYPICAL PROPERTIES OF COMMON INSULATING MATERIALS
BUTYL
SILICONE
PARAMETER
Specific Gravity
PVC
PE
PP
XLPE
NYLON
FEP
TFE
RUBBER
RUBBER
TPR
1.37
0.92
0.89
0.93-1.18
1.09
2.16
2.17
1.40
1.24
1.16-1.20
Dielectric Constant
(a) 60 Hz
(b) 1000 Hz
6.0
5.0
2.26
2.26
2.6
3.0
3.0
4.6
4.5
2.15
2.15
2.1
2.1
4.1
4.0
3.3
3.1
2.8
2.8
Dielectric Strength, v/mil
(a) 0.010” wall
(b) 0.040” wall
1800
800
2100
1050
850
450
-
1000
470
2000
950
2000
950
700
500
600
400
625
700
Tensil Strength, PSI x 1000
Service Temp, Range, °C
Elongation, %
1.5-3.8
-55/+105
200-375
<0.75
1.4-2.4
-90/+90
350-550
<0.02
2.9-4.5
-40/+105
700
1.8-2.5
-80/+75
250-400
<0.01
8.8-11.9
-55/+105
150-380
2.5
2.3-3.1
2.0-6.0
0.5-1.5
-40/+90
200-400
<1.0
0.6-1.2
-80/+200
125-400
<1.0
2.3
-55/+90
500
-90/+200 -90/+260
200-330
<0.01
200-500
<0.01
Water Absorption, % in 24 hr
<0.02
<0.6
Slow
Self
Extinguishing
Supports Supports
Slow
Flame
Self
Non-
Non-
Slow
Flame Resistance
(Non-Cond. Flammable
Ash)
Flame
Flame
Extinguishing Flammable Flammable Burning
Ozone Resistance
Flexibility
Excellent
Good
Good
Good
Good
Excellent
Good
Fair
Good
Good
Excellent
Good
Excellent
Good
Excellent
Excellent
Poor
Excellent
Excellent
Poor
Excellent
Excellent
Good-Fair
Excellent
Excellent
Poor
Good-Fair Good-Fair
Abrasion Resistance
Acid Resistance
Good
Excellent
Excellent
Excellent
Excellent
Excellent
Poor
Excellent
Excellent
Excellent
Excellent
Excellent
Excellent
Good-Fair
Fair-Poor
Excellent Excellent Excellent
Excellent Excellent Excellent
Excellent
Good
Good
Base Resistance
Excellent
Excellent
Excellent
Good
Hydraulic Fluid Resistance
Organic Solvent Resistance
Fair-Poor
Poor
Fair
Fair
Good-Fair Good-Fair
Fair Good-Fair
Poor
Fair-Poor
Poor
Excellent Good-Fair
Poor
NOTE: The above is representative of performance. For specific compound performance, consult Customer Service.
TYPICAL PROPERTIES OF COMMON JACKETING MATERIALS
SILICONE
POLY-
PARAMETER
Specific Gravity
PVC
PE
NYLON
FEP
TFE
RUBBER
NEOPRENE
URETHANE
TPR
1.37
0.92
1.09
2.16
2.17
1.24
1.52
1.3
1.16-1.20
2.3
Tensil Strength, PSI x 1000
Elongation, %
1.5-3.8
1.4-2.4
350-550
-80/+75
Good
8.8-11.9
150-380
-55/+105
Good
2.3-3.1
2.0-6.0
0.6-1.2
2.5-4.0
>3.5
200-375
-55/+105
Excellent
200-330
-90/+200
Excellent
200-500
-90/+200
Excellent
125-400
-80/+200
Excellent
300-500
-65/+90
Excellent
540-700
-65/+75
Good
500
Service Temp, Range, °C
Ozone Resistance
-55/+90
Excellent
Excellent-
Good
Weatherability
Good-Fair
Fair-Poor
Excellent
Excellent
Excellent
Good
Good
Excellent
Slow-Burn
(Non-Cond.
Ash)
Self
Extinguishing
Supports
Flame
Non-
Non-
Self
Flame Resistance
Flammable Flammable Flammable
Extinguishing Slow Burn Flammable
Flexibility
Good
Good
Good
Good
Good-Fair
Excellent
Poor
Good
Good
Excellent
Poor
Excellent
Excellent
Good
Excellent
Excellent
Fair
Excellent
Good-Fair
Excellent
Excellent
Good
Abrasion Resistance
Acid Resistance
Excellent
Excellent
Excellent
Excellent
Excellent
Good
Excellent
Excellent
Excellent
Excellent
Excellent
Good
Excellent
Excellent
Good-Fair
Fair-Poor
Good
Excellent
Excellent
Fair-Poor
Poor
Poor
Base Resistance
Excellent
Good-Fair
Good-Fair
Excellent
Good
Fair-Poor
Poor
Good
Fair
Hydraulic Fluid Resistance
Organic Solvent Resistance
Resistance to Tearing
Good
Poor
Good
Poor
Poor
Good
Fair
Good
Excellent
Good-Fair
NOTE: The above is representative of performance. For specific compound performance, consult Customer Service.
187
Electronics
Technical Information
Decimal Conversion Factors
FRACTIONS, DECIMALS AND MILLIMETER CONVERSION CHART
FRACTIONS OF AN INCH
EQUIVALENTS
FRACTIONS OF AN INCH
EQUIVALENTS
64
32
16
8
4
2
DECIMALS
mm
64
32
16
8
4
2
DECIMALS
mm
1
2
3
4
5
0.016
0.031
0.047
0.063
0.078
0.40
0.79
1.19
1.59
1.98
33
34
35
36
37
0.516
0.531
0.547
0.563
0.578
13.10
13.49
13.89
14.29
14.68
1
2
17
18
1
9
6
7
3
4
5
0.094
0.109
0.125
0.141
0.156
2.38
2.78
3.18
3.57
3.97
38
39
40
41
42
19
20
21
0.594
0.609
0.625
0.641
0.656
15.08
15.48
15.88
16.27
16.67
8
2
1
10
11
5
9
10
11
12
13
14
15
0.172
0.188
0.203
0.219
0.234
4.37
4.76
5.16
5.56
5.95
43
44
45
46
47
0.672
0.688
0.703
0.719
0.734
17.07
17.46
17.86
18.26
18.65
6
7
3
22
23
16
17
18
19
20
8
9
4
5
2
3
1
0.250
0.266
0.281
0.297
0.313
6.35
6.75
7.14
7.54
7.94
48
49
50
51
52
24
25
26
12
13
6
7
3
0.750
0.766
0.781
0.797
0.813
19.05
19.45
19.84
20.24
20.64
10
21
22
23
24
25
0.328
0.344
0.359
0.375
0.391
8.33
8.73
9.13
9.53
9.92
53
54
55
56
57
0.828
0.844
0.859
0.875
0.891
21.03
21.43
21.83
22.23
22.62
11
12
27
28
6
7
8
14
15
16
26
27
28
29
30
13
14
15
0.406
0.422
0.438
0.453
0.469
10.32
10.72
11.11
11.51
11.91
58
59
60
61
62
29
30
31
0.906
0.922
0.938
0.953
0.969
23.02
23.42
23.81
24.21
24.61
31
32
0.484
0.500
12.30
12.70
63
64
0.984
1.000
25.00
25.40
16
4
2
1
32
8
4
2
188
Technical Information
Electronics
Unit Conversion Factors
CONVERSION FACTORS
UNIT
X
CONSTANT
=
UNIT
UNIT
X
CONSTANT
=
UNIT
British Thermal Unit (BTU)
British Thermal Unit (BTU)
British Thermal Unit (BTU)
centimeters (cm)
centimeters (cm)
centimeters (cm)
centimeters (cm)
centimeters (cm)
circular mils (cmil)
circular mils (cmil)
circular mils (cmil)
circular mils (cmil)
cubic centimeter (cm3)
cubic centimeter (cm3)
cubic centimeter (cm3)
cubic centimeter (cm3)
cubic foot (ft3)
778.0
1054.35
0.293
0.032808
0.3937
0.00001
foot-pound (ft-lb)
joules (j)
watt-hours (w-hr)
feet (ft)
inches (in)
kilometers (km)
meters (m)
gallons (gal)
gallons (gal)
gallons (gal)
gallons (gal)
grams (g)
3.785411
0.13368
231.0
3785.411
15.432
0.0361275
33013.26
550.0
liters (l)
cubic foot (ft3)
cubic inch (in3)
cubic centimeter (cm3)
grains
gram/centimeter3 (gm/cm3)
horsepower (hp)
horsepower (hp)
horsepower (hp)
inch (in)
pounds/in3 (lb/in3)
ft-lb/min
0.010
10.0
millimeters (mm)
circular millimeters
inches2 (in2)
ft-lb/sec
watts (w)
yards (yd)
feet (ft)
kilometer (km)
meter (m)
centimeter (cm)
millimeter (mm)
mils
0.00064516
0.0000007854
0.00050671
0.7854
0.000035314
0.061023
0.000001
0.00026417
1728.0
28317.847
0.00057870
0.000016387
16.387064
1000000.0
35.314666
264.17
745.7
0.027178
0.083333
0.00002540
0.025400
2.54000514
25.4000514
1000.0
0.000948
107
61.02374
1.093611
3.2808333
39.37
100.0
1760.0
5280.0
1.6093
0.0032808
0.03937
0.001
0.01
39.3701
1000.0
square millimeters (mm2)
mils2
inch (in)
inch (in)
inch (in)
inch (in)
inch (in)
inch (in)
joules (j)
joules (j)
liters (l)
meters (m)
meters (m)
meters (m)
meters (m)
miles (mi)
miles (mi)
miles (mi)
cubic foot (ft3)
cubic inch (in3)
cubic meter (m3)
gallons (gal)
cubic in (in3)
British Thermal Unit (BTU)
ergs
cubic foot (ft3)
cubic centimeter (cm3)
cubic feet (ft3)
cubic meter (m3)
cubic centimeter (cm3)
centimeter (cm)
cubic foot (ft3)
gallons (gal)
cubic inch (in3)
cubic inch (in3)
cubic inch (in3)
cubic meter (m3)
cubic meter (m3)
cubic meter (m3)
feet (ft)
cubic inch (in3)
yard (yd)
feet (ft)
inch (in)
centimeter (cm)
yards (yd)
feet (ft)
kilometer (km)
feet (ft)
0.00018939
0.33333
miles (mi)
yards (yd)
inches (in)
kilometer (km)
meters (m)
feet (ft)
feet (ft)
feet (ft)
feet (ft)
feet (ft)
feet (ft)
12
millimeters (mm)
millimeters (mm)
millimeters (mm)
millimeters (mm)
millimeters (mm)
millimeters (mm)
watts (w)
watts (w)
watts (w)
watt-hours (w-hr)
0.00030480
0.30480
30.480
inch (in)
meters (m)
centimeters (cm)
mils
microns (µ)
ft-lb/minute
ft-lb/sec
centimeters (cm)
millimeters (mm)
meters/grams (m/g)
British Thermal Unit (BTU)
joules (j)
304.80
feet/pound (ft/lb)
foot-pound (ft-lb)
foot-pound (ft-lb)
foot-pound (ft-lb)
0.00067197
0.001285
1.356
44.25
0.737562
0.001341
3.414462
0.1383
kilogram/meter (kg/m)
horsepower
British Thermal Unit (BTU)
189
Electronics
Technical Information
Temperature Conversion Chart
To use this chart, find your known temperature (°F) in the shaded column.
˚C
˚F
˚C
˚F
˚C
˚F
˚C
˚F
˚C
˚F
101.0
102.0
103.0
104.0
105.0
106.0
107.0
108.0
109.0
110.0
38.3
38.9
39.4
40.0
40.6
41.1
41.7
42.2
42.8
43.3
51.0
52.0
53.0
54.0
55.0
56.0
57.0
58.0
59.0
60.0
10.6
11.1
11.7
12.2
12.8
13.3
13.9
14.4
15.0
15.6
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
-17.2
-16.7
-16.1
-15.6
-15.0
-14.4
-13.9
-13.3
-12.8
-12.2
151.0
152.0
153.0
154.0
155.0
156.0
157.0
158.0
159.0
160.0
-49.0
-48.0
-47.0
-46.0
-45.0
-44.0
-43.0
-42.0
-41.0
-40.0
66.1
66.7
67.2
67.8
68.3
68.9
69.4
70.0
70.6
71.1
-45.0
-44.4
-43.9
-43.3
-42.8
-42.2
-41.7
-41.1
-40.6
-40.0
111.0
112.0
113.0
114.0
115.0
116.0
117.0
118.0
119.0
120.0
43.9
44.4
45.0
45.6
46.1
46.7
47.2
47.8
48.3
48.9
61.0
62.0
63.0
64.0
65.0
66.0
67.0
68.0
69.0
70.0
16.1
16.7
17.2
17.8
18.3
18.9
19.4
20.0
20.6
21.1
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
-11.7
-11.1
-10.6
-10.0
-9.4
-8.9
-8.3
-7.8
-7.2
161.0
162.0
163.0
164.0
165.0
166.0
167.0
168.0
169.0
170.0
-39.0
-38.0
-37.0
-36.0
-35.0
-34.0
-33.0
-32.0
-31.0
-30.0
71.7
72.2
72.8
73.3
73.9
74.4
75.0
75.6
76.1
76.7
-39.4
-38.9
-38.3
-37.8
-37.2
-36.7
-36.1
-35.6
-35.0
-34.4
-6.7
121.0
122.0
123.0
124.0
125.0
126.0
127.0
128.0
129.0
130.0
49.4
50.0
50.6
51.1
51.7
52.2
52.8
53.3
53.9
54.4
71.0
72.0
73.0
74.0
75.0
76.0
77.0
78.0
79.0
80.0
21.7
22.2
22.8
23.3
23.9
24.4
25.0
25.6
26.1
26.7
21.0
22.0
23.0
24.0
25.0
26.0
27.0
28.0
29.0
30.0
-6.1
-5.6
-5.0
-4.4
-3.9
-3.3
-2.8
-2.2
-1.7
-1.1
171.0
172.0
173.0
174.0
175.0
176.0
177.0
178.0
179.0
180.0
-29.0
-28.0
-27.0
-26.0
-25.0
-24.0
-23.0
-22.0
-21.0
-20.0
77.2
77.8
78.3
78.9
79.4
80.0
80.6
81.1
81.7
82.2
-33.9
-33.3
-32.8
-32.2
-31.7
-31.1
-30.6
-30.0
-29.4
-28.9
131.0
132.0
133.0
134.0
135.0
136.0
137.0
138.0
139.0
140.0
55.0
55.6
56.1
56.7
57.2
57.8
58.3
58.9
59.4
60.0
81.0
82.0
83.0
84.0
85.0
86.0
87.0
88.0
89.0
90.0
27.2
27.8
28.3
28.9
29.4
30.0
30.6
31.1
31.7
32.2
31.0
32.0
33.0
34.0
35.0
36.0
37.0
38.0
39.0
40.0
-0.6
0.0
0.6
1.1
1.7
2.2
2.8
3.3
3.9
4.4
181.0
182.0
183.0
184.0
185.0
186.0
187.0
188.0
189.0
190.0
-19.0
-18.0
-17.0
-16.0
-15.0
-14.0
-13.0
-12.0
-11.0
-10.0
82.8
83.3
83.9
84.4
85.0
85.6
86.1
86.7
87.2
87.8
-28.3
-27.8
-27.2
-26.7
-26.1
-25.6
-25.0
-24.4
-23.9
-23.3
60.6
61.1
61.7
62.2
62.8
63.3
63.9
64.4
65.0
65.6
91.0
92.0
93.0
94.0
95.0
96.0
97.0
98.0
99.0
100.0
32.8
33.3
33.9
34.4
35.0
35.6
36.1
36.7
37.2
37.8
41.0
42.0
43.0
44.0
45.0
46.0
47.0
48.0
49.0
50.0
5.0
5.6
6.1
6.7
7.2
7.8
8.3
8.9
9.4
10.0
191.0
192.0
193.0
194.0
195.0
196.0
197.0
198.0
199.0
200.0
-9.0
-8.0
-7.0
-6.0
-5.0
-4.0
-3.0
-2.0
-1.0
0.0
88.3
88.9
89.4
90.0
90.6
91.1
91.7
92.2
92.8
93.3
-22.8
-22.2
-21.7
-21.1
-20.6
-20.0
-19.4
-18.9
-18.3
-17.8
141.0
142.0
143.0
144.0
145.0
146.0
147.0
148.0
149.0
150.0
TEMPERATURE CONVERSION FORMULA
9
5
°F = °C +32
5
°C = (°F-32)
9
190
Technical Information
Electronics
Conduit Capacity Chart
Conduit Trade Size
I.D. Inches
1/2
3/4
1
1 1/4
1.380
1.496
0.793
0.464
0.598
1 1/2
1.610
2.036
1.079
0.631
0.814
2
2 1/2
2.731
5.858
3.105
1.816
2.343
3
3 1/2
4
0.622
0.304
0.161
0.094
0.122
0.824
0.533
0.283
0.165
0.213
1.049
0.864
0.458
0.268
0.346
2.067
3.356
1.778
1.040
1.342
3.356
8.846
4.688
2.742
3.538
3.834
11.545
6.119
3.579
4.618
4.334
14.753
7.819
4.573
5.901
Internal Area, In2
1 Conductor (53% fill)
2 Conductors (31% fill)
Conductors (40% fill)
Cable OD
Inches
Cable
Numbers listed below are based on the 2008 NEC (40% fill ) for 3 or more non-lead covered cables.
Area In2
0.100
0.125
0.150
0.175
0.200
0.225
0.250
0.275
0.300
0.325
0.350
0.375
0.400
0.425
0.450
0.475
0.500
0.525
0.550
0.575
0.600
0.625
0.650
0.675
0.700
0.725
0.750
0.775
0.800
0.825
0.850
0.875
0.900
0.925
0.950
0.975
1.000
1.025
1.050
1.075
0.008
0.012
0.018
0.024
0.031
0.040
0.049
0.059
0.071
0.083
0.096
0.110
0.126
0.142
0.159
0.177
0.196
0.216
0.238
0.260
0.283
0.307
0.332
0.358
0.385
0.413
0.442
0.472
0.503
0.535
0.567
0.601
0.636
0.672
0.709
0.747
0.785
0.825
0.866
0.908
15
9
6
5
3
3
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
26
17
11
8
6
5
4
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
43
27
19
14
10
8
6
5
4
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
76
48
33
24
19
15
12
10
8
7
6
5
4
4
3
3
3
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
104
66
46
34
26
20
16
13
11
9
8
7
6
5
5
4
4
3
3
3
2
2
1
1
1
1
1
1
1
1
1
1
1
1
170
109
75
55
42
33
27
22
18
16
13
12
10
9
8
7
6
6
5
5
4
4
4
3
3
3
3
2
2
1
1
1
1
1
1
1
1
1
244
156
108
79
81
48
39
32
27
23
19
17
15
13
12
10
9
8
8
7
6
6
5
5
5
4
4
4
3
3
3
3
3
2
2
1
1
1
1
1
375
240
166
122
93
74
60
49
41
35
30
26
23
20
18
17
15
13
12
11
10
9
8
8
7
7
6
6
5
5
5
4
4
4
4
3
3
3
504
322
224
164
126
99
80
66
56
47
41
35
31
27
24
22
20
18
16
15
14
12
11
11
10
9
8
8
7
7
6
6
6
5
5
5
5
4
4
4
648
414
288
211
162
128
103
85
72
61
52
46
40
35
32
28
25
23
21
19
18
16
15
14
13
12
11
10
10
9
8
8
8
7
7
6
6
6
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
1
1
3
3
5
5
Notice: 1. The reader is cautioned to consult the 2008 NEC for specific informatioon regarding conduit fill.
2. This Conduit Capacity Chart should only be used as a guide when attempting to estimate conduit fill.
3. For additional information, the reader should refer to the 2008 National Electrical Code, Chapter 9.
191
Electronics
Technical Information
Coax Connector Cross Reference
BNC TYPE CONNECTORS
CAMBRIDGE
GEM
LRC
RF INDUSTRIES
TROMPETER
CATALOG NUMBER
BNC CRIMP PLUG
BNC COMPRESSION PLUG
SNAP-N-SEAL
BNC CRIMP PLUG
BNC CRIMP PLUG
RG 6/U
CPMC-68-36
CPMC-68-36
—
—
—
RFB-1707-Q1
—
105-1516-9
105-1516-9
105-1516-9
105-1516-9
105-1516-9
UPL20-34
105-1153-9
105-1153-9
105-1153-9
105-1153-9
UPL20-41
UPL20-41
UPL20-41
UPL20-41
UPL20-41
105-1153-9
UPL20-41
UPL20-41
105-1516-9
C3521
C3523
C3524
C3525
C5760
C5761
C5775
C5776
C5777
C5778
C5785
C5802
C5804
C5814
C5822
C5886
C5889
C8029
C8031
302-510CS
CPMC-68-36
302-510CS
—
—
CPMC-68-36
—
—
—
CPMC-68-45
—
—
RFB-1707-Q1
—
CPMC-68-45
302-5CSQS
SNS6BNC
SNS6BNC
SNS6BNC
SNS6BNC
SNS6BNC
SNS6QSBNC
SNS6BNC
SNS6BNC
SNS6BNC
SNS6BNC
SNS6BNC
SNS6QSBNC
SNS6BNC
—
CPMC-68-45
302-5CSQS
—
CPMC-68-45
—
—
CPMC-68-45
—
RFB-1707-Q
RFB-1707-Q
—
CPMC-68-45
—
302-5CSQS
—
CPFI-UG88-3 (TWIST ON)
CPMC-68-45
RFB-1707-Q
RFB-1707-Q
RFB-1707-Q
RFB-1707-Q
RFB-1707-Q
—
CPMC-68-45
—
CPMC-68-45
302-5CSQS
302-5CSQS
—
CPMC-68-45
CPMC-68-45
CPFI-UG88-3 (TWIST ON)
CPMC-68-45
302-5CSQS
302-5CS
—
RFB-1707-Q
RFB-1707-Q1
CPMC-68-36
TROMPETER
CATALOG NUMBER
RG 7/U
C5851
BNC CRIMP PLUG
PL20-48
105-1677-1
PL20-48
C5853
C5856
PL20-48
C5857
AMP
CAMBRIDGE
GEM
KINGS ELECTRONICS
BNC CRIMP PLUG
RF INDUSTRIES
TROMPETER
CATALOG NUMBER
RG 8/U
C1108
BNC PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
BNC PLUG
BNC CRIMP PLUG
—
CPMC-88-17
305-17
—
—
RFB-1107-1X
RFB-1101-1EN
RFB-1101-1EN
RFB-1101-1SI
RFB-1101-1SI
PL20-52
PL20-6A
N/A
2-225295-1
—
—
—
—
KC-59-577 MO6
KC-59-642 MO6
C1154
C1180
C1197
C1198
—
—
—
—
—
PL20-6A
PL20-6A
—
CAMBRIDGE
GEM
RF INDUSTRIES
TROMPETER
CATALOG NUMBER
BNC CRIMP PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
RG 11/U
CPMC-88-26
CPMC-88-27
CPMC-88-28
CPMC-88-29
CPMC-88-30
CPMC-88-30
CPMC-88-32
CPMC-88-33
CPMC-88-35
CPMC-88-36
305-26
—
RFB-1707-R1
—
UPL20-6A
UPL20-6A
UPL20-6A
UPL20-6A
UPL20-6A
UPL20-6A
UPL20-6A
UPL20-6A
UPL20-6A
UPL20-6A
C1160
C3528
C3529
C5011
C5025
C5029
C5034
C5039
C5043
C5044
—
—
—
RFB-1707-R
RFB-1707-R
RFB-1707-R
RFB-1707-R
RFB-1707-R
RFB-1707-R
RFB-1707-R
—
—
—
—
—
—
AMP
www.tycoelectronics.com
www.cambridgeconnectors.com
www.gemelec.com
Cambridge
GEM
Ideal
www.idealindustries.com
www.kingselectronics.com
www.rfindustries.com
Kings Electronics
RF Industries
Trompeter
www.trompeter.com
192
Technical Information
Electronics
Coax Connector Cross Reference
BNC TYPE CONNECTORS
AMP
CAMBRIDGE
GEM
IDEAL
KINGS ELECTRONICS
BNC CRIMP PLUG
RF INDUSTRIES
TROMPETER
CATALOG NUMBER
RG 58/U
C1117
BNC PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
BNC PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
22709-5
22709-5
CPMC-88-1
CPMC-88-1
CPMC-88-1
CPMC-88-1
CPMC-88-1
CPMC-88-11
CPMC-88-11
CPMC-88-1
305-1
305-1
305-1
305-1
305-1
305-11
305-11
305-1
IA-3620
IA-3620
IA-3620
IA-3620
IA-3620
–
755-115-5
RFB-1106-2
RFB-1106-2
RFB-1106-2
RFB-1106-2
RFB-1106-2
RFB-1707-7
RFB-1707-7
–
PL20-1
PL20-1
755-115-5
C1155
C1166
C1178
C1188
C3519
C3579
C5779
22709-5
755-115-5
PL20-1
22709-5
755-115-5
PL20-1
22709-5
–
–
–
–
PL20-1
6-22709-8
6-22709-8
6-22709-8
PL20-4
IA-3623
–
PL20-4
105-1598-1
AMP
CAMBRIDGE
GEM
KINGS ELECTRONICS
LRC
RF INDUSTRIES
TROMPETER
BNC COMPRESSION
PLUG BNC CRIMP PLUG SNAP-N-SEAL BNC BNC CRIMP PLUG BNC CRIMP PLUG
CATALOG NUMBER
RG 59/U
C1102
C1103
C1104
C1106
C1110
C1112
C1135
C1142
C1158
C3500
C3526
C3527
C5770
C5780
C5784
C5830
C8025
C8027
C8028
C8030
BNC PLUG
BNC CRIMP PLUG
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
CPMC-78-2
CPMC-78-2
CPMC-78-2
CPMC-78-2
CPMC-78-2
CPMC-78-2
CPMC-78-2
CPMC-68-35
CPMC-78-18
CPMC-68-35
CPMC-68-50
CPMC-68-35
CPMC-68-35
CPMC-68-35
CP-88-4 (TWIST ON)
CPMC-78-2
CPMC-78-2
CPMC-78-2
CPMC-78-2
CPMC-68-10
307-2 (Crimp)
307-2CS
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
SNS59BNC
RFB-1707-D1
RFB-1707-D1
RFB-1707-D
RFB-1707-D
RFB-1707-D
RFB-1707-D
RFB-1707-D
RFB-1707-W
–
UPL20-2
UPL20-2
–
307-2 (Crimp)
307-2 (Crimp)
307-2 (Crimp)
307-2 (Crimp)
307-2 (Crimp)
307-2CS
SNS59BNC
UPL20-2
SNS59BNC
UPL20-2
SNS59BNC
UPL20-2
SNS59BNC
UPL20-2
SNS59BNC
UPL20-2
SNS59BNC
UPL20-2A
UPL20-22
105-1287-9
105-1184-9
UPL20-53
UPL20-2A
UPL20-2A
105-1558-9
UPL20-2
307-18 (Crimp)
302-10CS
–
–
–
–
–
–
–
–
–
302-2CS
–
RFB-1707-W
RFB-1707-W
–
302-2CS
SNS59BNC
–
–
307-2 (Crimp)
302-10CS
302-10CS
307-2 (Crimp)
–
SNS59BNC
RFB-1707-D1
RFB-1707-D
–
–
UPL20-2
–
UPL20-2
SNS59BNC
–
–
UPL20-2
RFB-1707-D3
105-1287-9
AMP
CAMBRIDGE
GEM
KINGS ELECTRONICS
TROMPETER
CATALOG NUMBER
RG 62/U
C1162
BNC PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
22709-7
22709-7
CPMC-78-2
CPMC-78-2
CPMC-68-2
307-2
307-2
–
755-155-5
755-155-5
–
UPL20-2
UPL20-2
C1164
C3520
4-22709-9
105-1287-1
AMP
CAMBRIDGE
GEM
KINGS ELECTRONICS
BNC CRIMP PLUG
RF INDUSTRIES
TROMPETER
CATALOG NUMBER
RG 174/U
C1156
BNC PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
1-22709-6
CPMC-88-19
305-19
KC-59-557 M06
RFB-1106-5
PL20-5
AMP
CAMBRIDGE
GEM
RF INDUSTRIES
TROMPETER
CATALOG NUMBER
RG 213 /U
BNC PLUG
BNC CRIMP PLUG
BNC CRIMP PLUG
BNC CLAMP PLUG
BNC CLAMP PLUG
2-225395-1
CPMC-88-26
305-26
RFB-1101-1SI
PL20-6A
C1176A
AMP
www.tycoelectronics.com
Cambridge
GEM
www.cambridgeconnectors.com
www.gemelec.com
Ideal
www.idealindustries.com
www.kingselectronics.com
www.rfindustries.com
Kings Electronics
RF Industries
Trompeter
www.trompeter.com
193
Electronics
Technical Information
Coax Connector Cross Reference
F-TYPE CONNECTORS
CAMBRIDGE
GEM
GILBERT
F-TYPE COMPRESSION
IDEAL INDUSTRIES
CATALOG NUMBER
RG 6/U
F-TYPE CRIMP
F-TYPE COMPRESSION
F-TYPE CRIMP
F-TYPE
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALMWP
CPF-56-ALM
CPF-56-ALM
CPF-56-ALM
CPF-56-ALS
CPF-56-ALM
CPF-56-ALM
0406-4 (Crimp)
0406-610CS
0406-610CS
0406-4 (Crimp)
0406-4 (Crimp)
0406-6CSQS
0406-6CSQS
0406-4 (Crimp)
0406-4 (Crimp)
0406-4 (Crimp)
0406-6CSQS
0406-4 (Crimp)
–
GF-6-AHS/USA
NS-8101-15
Contact Gilbert
Contact Gilbert
Contact Gilbert
Contact Gilbert
GF-UR-6
–
C3521
C3523
C3524
C3525
C5760
C5761
C5775
C5776
C5777
C5778
C5785
C5802
C5804
C5814
C5822
C5886
C5889
C8029
C8031
–
Contact Gilbert
Contact Gilbert
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
GF-6-AHS/USA
Contact Gilbert
Contact Gilbert
–
–
–
GF-UR-6
85-037
85-037
85-037
85-037
–
GF-UR-6
GF-UR-6
GF-UR-6
GF-UR-6
GF-UR-6
85-057
85-037
85-037
85-037
85-037
85-037
85-057
–
GF-UR-6
GF-UR-6
0406-6CSQS
0406-6CSQS
0406-4 (Crimp)
0406-6CSQS
0406-6CS
GF-UR-6
GF-UR-6
GF-UR-6
GF-UR-6
Contact Gilbert
Contact Gilbert
0406-4 (Crimp)
–
LRC
PPC
TROMPETER
U SERIES
UV SERIES
UV-INDOOR
SUV INDOOR/OUTDOOR
EX
CATALOG NUMBER
F-TYPE CRIMP
SNAP-N-SEAL
U-INDOOR
F-TYPE CRIMP
INDOOR/OUTDOOR
SU-OUTDOOR
RG 6/U (cont.)
C3521
C3523
C3524
C3525
C5760
C5761
C5774
C5775
C5776
C5777
C5778
C5785
C5802
C5804
C5810
C5812
C5814
C5822
C5824
C5826
C5886
C5888
C5889
C5890
C8029
C8031
–
–
–
CFS 6 PL
CFS 6 PL
CFS 6 PL
–
–
EX6P or EX6XLP
EX6P or EX6XLP
EX6P or EX6XLP
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
–
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
–
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
–
–
AMF6
AMF6
AMF6
AMF6
AMF6
AMF6
AMF6
AMF6
AMF6
–
SNS6
SNS6
SNS6
SNS6
SNS6
SNS6
SNS6QS
SNS6
SNS6
–
PL130SC-020
PL130SC-020
–
PL130SC-020
PL130SC-020
PL130SC-020
–
PL130SC-020
PL130SC-020
PL130SC-017
–
–
–
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
CFS 6 U (SU)
–
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
CFS 6 UV (SUV)
–
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
EX6 or EX6XLP
–
AMF6
AMF6
AMF6
AMF6
AMF6
AMF6
AMF6
AMF6
AMF6
–
SNS6
SNS6
SNS6
SNS6
SNS6
SNS6
SNS6QS
SNS6
SNS6
–
PL130SC-020
PL130SC-020
PL130SC-020
PL130SC-020
–
PL130SC-020
–
–
–
–
PL130SC-020
PL130SC-020
–
–
–
–
–
–
–
AMP
www.tycoelectronics.com
Cambridge
GEM
www.cambridgeconnectors.com
www.gemelec.com
Ideal
www.idealindustries.com
www.kingselectronics.com
www.rfindustries.com
Kings Electronics
RF Industries
Trompeter
www.trompeter.com
194
Technical Information
Electronics
Coax Connector Cross Reference
F-TYPE CONNECTORS
GILBERT
LRC
PPC
PNU SERIES
PNU-INDOOR
PNSU INDOOR/
OUTDOOR
U SERIES
U-INDOOR
SU-OUTDOOR
F-TYPE
COMPRESSION
EX
CATALOG NUMBER
F-TYPE CRIMP
F-TYPE CRIMP
SNAP-N-SEAL
INDOOR/OUTDOOR
RG 7/U
C5851
C5853
C5856
C5857
GAF-236/051-AHS/368
GAF-236/051-AHS/368
GAF-236/051-AHS/368
GAF-236/051-AHS/398
GAF-UST-7
GAF-UST-7
GAF-UST-7
GAF-UST-7Q
AMF7
SNS7B
CFS 7 U (SU)
CFS 7 U (SU)
CFS 7 U (SU)
CFS 7 U (SU)
CFS 7 PNU (PNSU)
CFS 7 PNU (PNSU)
CFS 7 PNU (PNSU)
CFS 7 PNU (PNSU)
EX 7
EX 7
EX 7
–
–
–
–
–
–
–
CAMBRIDGE
GILBERT
LRC
PPC
UV SERIES
UV-INDOOR
SUB INDOOR/
OUTDOOR
U SERIES
U-INDOOR
SU-OUTDOOR
EX
INDOOR/
OUTDOOR
CATALOG
NUMBER
F-TYPE
CRIMP
F-TYPE
CRIMP
F-TYPE
COMPRESSION
F-TYPE
CRIMP
SNAP-N-SEAL
RG 11/U
C1160
C3528
C3529
C5011
C5025
C5029
C5034
C5039
C5043
C5044
CPF-11-ALM Contact Gilbert Contact Gilbert
CPF-11-ALM Contact Gilbert Contact Gilbert
CPF-11-ALM Contact Gilbert Contact Gilbert
CPF-11-ALM GF-11-AHS/460 GAF-UST-11
CPF-11-ALM Contact Gilbert Contact Gilbert
CPF-11-ALM GF-11-AHS/460 GAF-UST-11
CPF-11-ALM GF-11-AHS/460 GAF-UST-11
CPF-11-ALM GF-11-AHS/460 GAF-UST-11
CPF-11-ALM GF-11-AHS/460 GAF-UST-11
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
AMF11
–
SNS11AS
–
CFS 11 U (SU) CFS 11 PNU (PNSU)
CFS 11 U (SU) CFS 11 PNU (PNSU)
CFS 11 U (SU) CFS 11 PNU (PNSU)
CFS 11 U (SU) CFS 11 PNU (PNSU)
CFS 11 U (SU) CFS 11 PNU (PNSU)
CFS 11 U (SU) CFS 11 PNU (PNSU)
CFS 11 U (SU) CFS 11 PNU (PNSU)
EX 11
EX 11
EX 11
EX 11
EX 11
EX 11
EX 11
AMF11
AMF11
AMF11
AMF11
AMF11
SNS11AS
SNS11AS
SNS11AS
SNS11AS
SNS11AS
–
GF-11-AHS/480 GAF-UST-11Q
CAMBRIDGE
GEM
GILBERT
IDEAL INDUSTRIES
LRC
CATALOG NUMBER
RG 59/U
C1102
C1103
C1104
C1106
C1110
C1112
C1135
C1142
C1158
C3500
C3526
C3527
C5770
C5780
C5784
C5830
C8025
C8027
C8028
C8030
F-TYPE CRIMP
F-TYPE COMPRESSION
F-TYPE CRIMP
F-TYPE COMPRESSION
F-TYPE
F-TYPE CRIMP
SNAP-N-SEAL
CPF-59-ALM
CPF-59-ALM
CPF-59-ALM
CPF-59-ALM
CPF-59-ALM
CPF-59-ALM
CPF-59-ALM
CPF-59-ALM
–
0459-2M (Crimp)
0459-2CS
GF-59-AHS/USA
GF-59-AHS/USA
GF-59-AHS/USA
GF-59-AHS/USA
GF-59-AHS/USA
GF-59-AHS/USA
GF-59-AHS/USA
GF-59-AHS/USA
GF-1097-17
GF-UR-59
GF-UR-59
85-036
85-036
85-036
85-036
85-036
85-036
85-036
85-036
–
AMF59
SNS59
–
–
0459-2M (Crimp)
0459-2M (Crimp)
0459-2M (Crimp)
0459-2M (Crimp)
0459-2M (Crimp)
0459-2CS
GF-UR-59
AMF59
SNS59
GF-UR-59
AMF59
SNS59
GF-UR-59
AMF59
SNS59
GF-UR-59
AMF59
SNS59
GF-UR-59
AMF59
SNS59
GF-UR-59
AMF59
SNS59
–
Contact Gilbert
Contact Gilbert
Contact Gilbert
Contact Gilbert
Contact Gilbert
GF-UR-59
–
–
–
0459-10CS
Contact Gilbert
Contact Gilbert
Contact Gilbert
Contact Gilbert
GF-59-AHS/USA
GF-59-AHS/357
GF-59-AHS/USA
Contact Gilbert
Contact Gilbert
Contact Gilbert
Contact Gilbert
–
–
–
–
–
–
–
–
CPF-59-ALM
CPF-59-ALM
CPF-59-ALM
–
0459-2M (Crimp)
0459-2CS
–
–
–
85-036
85-036
85-059
85-036
–
–
–
SNS59
SNS59QS
SNS59
–
0459-2M (Crimp)
–
AMF59
Contact Gilbert
GF-UR-59
–
CPF-59-ALM
CPF-59-ALM
CPF-59-ALM
CPF-59-ALM
CPF-59-ALM
0459-2M (Crimp)
0459-10CS
AMF59
Contact Gilbert
Contact Gilbert
Contact Gilbert
Contact Gilbert
–
0459-10CS
–
–
AMF59
–
–
0459-2M (Crimp)
0459-2M (Crimp)
–
SNS59
–
–
AMP
www.tycoelectronics.com
Cambridge
GEM
www.cambridgeconnectors.com
www.gemelec.com
Ideal
www.idealindustries.com
www.kingselectronics.com
www.rfindustries.com
Kings Electronics
RF Industries
Trompeter
www.trompeter.com
195
Electronics
Technical Information
Coax Connector Cross Reference
F-TYPE CONNECTORS
PPC
TROMPETER
TROMPETER
UV SERIES
CATALOG NUMBER
F-TYPE CRIMP
U SERIES
UV-INDOOR
SUV INDOOR/
OUTDOOR
EX
CATALOG NUMBER
U-INDOOR
F-TYPE CRIMP
RG 62/U
C1162
INDOOR/OUTDDOR
SU-OUTDOOR
PL130SC-013
PL130SC-013
–
RG 59/U (cont.)
C1102
C1103
C1104
C1106
C1110
C1112
C1135
C1142
C1158
C3500
C3526
C3527
C5770
C5780
C5784
C5830
C8025
C8027
C8028
C8030
C1164
C3520
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
PL130SC-014
PL130SC-013
PL130SC-013
PL130SC-013
PL130SC-013
PL130SC-013
PL130SC-013
PL130SC-023
PL130SC-008
–
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
TROMPETER
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
CATALOG NUMBER
RG 174/U
C1156
F-TYPE CRIMP
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
PL130SC-004
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
–
–
–
–
–
–
–
–
–
–
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
PL130SC-023
PL130SC-022
PL130SC-023
–
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
CFS 59 U (SU)
CFS 59 UV (SUV)
EX59 or EX59XL
PL130SC-013A
PL130SC-013
PL130SC-013
PL130SC-013A
–
–
–
–
–
–
–
–
–
–
–
–
–
AMP
www.tycoelectronics.com
www.cambridgeconnectors.com
www.gemelec.com
Cambridge
GEM
Ideal
www.idealindustries.com
www.kingselectronics.com
www.rfindustries.com
Kings Electronics
RF Industries
Trompeter
www.trompeter.com
196
Technical Information
Electronics
Coax Connector Cross Reference
N-TYPE CONNECTORS
TROMPETER
TROMPETER
CATALOG NUMBER
N-TYPE CRIMP PLUG
CATALOG NUMBER
N-TYPE CRIMP PLUG
RG 6/U
RG 7/U
—
PL95-48
N/A
C3521
C3523
C3524
C3525
C5760
C5761
C5775
C5776
C5777
C5778
C5785
C5802
C5804
C5814
C5822
C5886
C5889
C8029
C8031
C5851
C5853
C5856
C5857
—
—
PL95-48
PL95-48
—
—
UPL95-34
—
—
—
—
—
—
—
—
UPL95-41
—
UPL95-41
UPL95-41
—
AMP
CAMBRIDGE
KINGS ELECTRONICS
N-TYPE CRIMP PLUG
LRC
RF INDUSTRIES
TROMPETER
N-TYPE PLUG
CATALOG NUMBER
RG 8/U
N-TYPE PLUG
N-TYPE CRIMP PLUG
N-TYPE PLUG
N-TYPE CRIMP PLUG
—
225661-2 (Mil)
415232-6
—
—
—
—
—
RFN-1007-2SX
RFN-1006-3E
RFN-1006-3E
RFN-1006-3I
—
C1108
CPN-68-8
CPN-8/110
CPN-68-8
KN-59-176
1205-4-9
1205-4-9
PL95-6A
—
C1154
C1180
C1198
NM8HB10
—
1-225661-6 (Mil)
414160-4
RFN-1006-3I
PL95-6A
CAMBRIDGE
TROMPETER
CATALOG NUMBER
RG 11/U
C1160
N-TYPE CRIMP PLUG
N-TYPE CRIMP PLUG
CPN-8
CPN-8
UPL95-6A
UPL95-6A
UPL95-6A
UPL95-6A
UPL95-6A
UPL95-6A
UPL95-6A
UPL95-6A
UPL95-6A
UPL95-6A
C3528
C3529
C5011
C5025
C5029
C5034
C5039
C5043
CPN-8
CPN-8
CPN-68-8
CPN-8
CPN-8
CPN-8
CPN-8
CPN-68-8
C5044
AMP
www.tycoelectronics.com
Cambridge
GEM
www.cambridgeconnectors.com
www.gemelec.com
Ideal
www.idealindustries.com
www.kingselectronics.com
www.rfindustries.com
Kings Electronics
RF Industries
Trompeter
www.trompeter.com
197
Electronics
Technical Information
Coax Connector Cross Reference
N-TYPE CONNECTORS
AMP
CAMBRIDGE
KINGS ELECTRONICS
N-TYPE CRIMP PLUG
RF INDUSTRIES
TROMPETER
CATALOG NUMBER
N-TYPE PLUG
N-TYPE CRIMP PLUG
N-TYPE CRIMP PLUG
N-TYPE CRIMP PLUG
RG 58/U
1-225661-2 (Mil)
415232-2
CPN-68-1
CPN-68-1
CPN-68-1
CPN-68-1
CPN-68-1
1205-19-5
1205-19-5
1205-19-5
1205-19-5
—
RFN-1005-3C
RFN-1005-3C
RFN-1005-3C
RFN-1005-3C
RFN-1005-3C
PL95-1
PL95-1
PL95-1
PL95-1
PL95-1
C1117
C1155
C1166
C1178
C1188
1-225661-2 (Mil)
415232-2
1-225661-2 (Mil)
415232-2
1-225661-2 (Mil)
415232-2
1-225661-2 (Mil)
415232-2
—
CPN-1
CPN-1
CPN-1
—
—
—
—
—
—
PL95-4
PL95-4
—
C3519
C3579
C5779
—
—
AMP
CAMBRIDGE
GEM
RF INDUSTRIES
TROMPETER
CATALOG NUMBER
N-TYPE PLUG
N-TYPE CRIMP PLUG
N-TYPE CRIMP PLUG
N-TYPE CRIMP PLUG
N-TYPE CRIMP PLUG
RG 59/U
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
CPN-2
CPN-2
CPN-2
CPN-2
CPN-2
CPN-2
—
—
400-2
400-2
400-2
400-2
400-2
400-2
—
RFN-1907-2S
UPL95-2
UPL95-2
UPL95-2
UPL95-2
UPL95-2
UPL95-2
UPL95-2
UPL95-2A
UPL95-22
—
C1102
C1103
C1104
C1106
C1110
C1112
C1135
C1142
C1158
C3500
C3526
C3527
C5770
C5780
C5784
C5830
C8025
C8027
C8028
C8030
RFN-1907-2S
RFN-1907-2S
RFN-1907-2S
RFN-1907-2S
RFN-1907-2S
RFN-1907-2S
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
UPL95-2A
UPL95-2A
—
—
—
—
—
—
—
—
—
RFN-1907-2S
UPL95-2
UPL95-2
UPL95-2
UPL95-2
—
CPN-2
CPN-2
—
400-2
400-2
—
—
—
—
—
—
—
AMP
www.tycoelectronics.com
Cambridge
GEM
www.cambridgeconnectors.com
www.gemelec.com
Ideal
www.idealindustries.com
www.kingselectronics.com
www.rfindustries.com
Kings Electronics
RF Industries
Trompeter
www.trompeter.com
198
Technical Information
Electronics
Coax Connector Cross Reference
N-TYPE CONNECTORS
AMP
CAMBRIDGE
GEM
TROMPETER
N-TYPE PLUG
CATALOG NUMBER
N-TYPE PLUG
N-TYPE CRIMP PLUG
N-TYPE CRIMP PLUG
RG 62/U
—
—
—
CPN-2
CPN-2
—
400-2
400-2
—
UPL95-2
UPL95-2
—
C1162
C1164
C3520
AMP
RF INDUSTRIES
N-TYPE PLUG
TROMPETER
N-TYPE PLUG
CATALOG NUMBER
N-TYPE PLUG
RG 174/U
—
RFN-1005-B-03
PL95-5
C1156
AMP
CAMBRIDGE
KINGS ELECTRONICS
N-TYPE CRIMP PLUG
RF INDUSTRIES
TROMPETER
N-TYPE PLUG
CATALOG NUMBER
N-TYPE PLUG
N-TYPE CRIMP PLUG
N-TYPE PLUG
RG 213/U
C1176A
1-227086-0 (MIL)
415232-6
CPN-68-8
KN-59-202
RFN-1006-3I
PL95-6A
ONE-PIECE CONNECTORS
WHITE SANDS ENGINEERING
ONE-PIECE CONNECTOR
GENERAL CABLE
RG 6/U
395025
395011
SLC59
SLCUHEC2
SLC6/SLC6O
SLC6Q/SLC6QO
BNCFP59
395025
395025
BNCFPSLC59
BNCFPSLCHEC
395011
395011
BNCFP6
BNCFPSLC6/BNCFPSLC6G
BNCFPSLC6Q/BNCFPSLC6QG
RCAFP59
395025
395025
395011
RCAFPSLC59/RCAFPSLC59G
RCAFPSLC6/RCAFPSLC6G
RCAFPSLC6QG
AMP
www.tycoelectronics.com
www.cambridgeconnectors.com
www.gemelec.com
Cambridge
GEM
Ideal
www.idealindustries.com
www.kingselectronics.com
www.rfindustries.com
Kings Electronics
RF Industries
Trompeter
White Sands
www.trompeter.com
www.whitesandsengineering.com
199
Electronics
Technical Information
AWG Conductor Chart
COPPER CONDUCTOR DATA
The conductors used by General Cable meet the applicable requirements of ASTM specifications B-3, B-33, B-172, B-173, B-174 and B-286 and
Federal Specification QQ-W-343.
The following data covers the more commonly used conductor constructions in the electrical and electronics industry. Special constructions, not
shown, are available or can be designed to meet specific requirements. It is suggested that the General Cable Product Engineering Department be
contacted before a specification is finalized.
D.C. RESISTANCE 20°C(2)
DIAMETER(4)
AREA
circ. mils
WEIGHT
TIN COATING(3)
BARE OF SILVER COATING
TYPE
BREAK STR.
LBS
AWG STRANDING STRANDING(1)
in
mm
sq. mm
lbs/Mft
kg/km
Ω/Mft
Ω/km
Ω/Mft
Ω/km
7/40
Solid
7/38
Co or Bu
–
Bu
.0096
.010
.012
.254
.254
.305
100
100
112
.051
.051
.057
.21
.30
.35
.31
.45
.52
176.00
113.00
106.00
577.00
371.00
348.00
164.00
104.00
92.60
538.00
340.00
303.00
1.986
3.157
32
30
Solid
7/36
Solid
7/35
Solid
7/34
10/36
19/38
–
.01264
.015
.0142
.017
.016
.019
.0193
.021
.321
.381
.361
.432
.404
.483
.490
.533
159
175
202
220
253
278
250
304
.081
.089
.102
.111
.128
.141
.127
.154
.48
.55
.61
.69
.77
.87
.78
.97
.72
.82
.91
1.04
1.14
1.29
1.15
1.44
70.80
67.50
55.60
53.80
44.50
42.50
47.30
38.90
232.00
221.00
182.00
176.00
146.00
139.00
155.00
128.00
65.30
59.30
51.40
–
41.00
37.30
40.40
34.10
214.00
194.00
169.00
–
135.00
122.00
133.00
112.00
5.020
6.331
7.983
28
27
Co
–
Co or Bu
–
Co or Bu
Bu
26
Bu or Co
Solid
7/32
–
.0201
.024
.024
.025
.025
.030
.0315
.032
.038
.037
.040
.039
.511
.610
.610
.635
.643
.762
.800
404
448
400
475
643
700
754
.205
.227
.201
.241
.324
.355
.382
.519
.562
.507
.616
.523
1.22
1.38
1.25
1.48
1.94
2.19
2.35
3.10
3.49
3.14
3.84
3.28
1.82
2.05
1.64
2.20
2.89
3.26
3.50
4.61
5.19
4.67
5.71
4.88
27.20
25.70
29.50
24.90
16.70
16.60
15.50
10.50
10.30
11.40
9.48
11.30
–
89.20
84.20
96.80
81.70
54.80
54.40
50.80
34.40
33.80
37.40
31.10
37.10
25.70
23.10
27.50
21.80
16.20
14.80
13.80
10.10
9.33
10.40
8.53
–
84.20
75.90
90.20
71.60
53.20
48.60
45.10
33.20
30.60
34.00
28.00
–
12.690
Co or Bu
Bu
24
22
16/36
19/36
Co or Bu
Solid
7/30
19/34
Solid
7/28
10/30
19/32
26/34
Solid
Solid
7/26
16/30
19/30
41/34
–
19.430
30.890
Co or Bu
Bu or Eq
–
.813
.965
.940
1,020
Co or Bu
Bu
1,111
1,000
1,216
20
19
18
Co, Bu or Eq
Bu
1.02
.940
.912
–
–
.0359
1,032
.653
3.90
5.80
–
8.05
26.40
38.950
49.120
.0403
.048
1.024
1.22
1,290
1,620
1,770
1,600
1,900
.823
.897
.810
.963
.824
4.92
5.55
5.01
5.95
5.09
7.32
8.26
7.45
8.85
7.08
6.77
6.45
7.15
6.10
7.08
22.20
21.20
23.40
20.00
23.20
6.39
5.55
6.48
5.46
6.60
21.00
19.20
21.30
17.90
21.60
Co or Bu
Bu
.0475
.050
1.207
1.27
Co, Bu or Eq
Bu
.049
1.244
Solid
–
.0508
.057
1.29
1.45
1.50
1.54
1.52
1.63
1.85
1.80
1.88
1.96
1,627
2,580
2,426
2,601
2,600
2,581
4,110
4,100
3,831
4,106
4,100
6,530
6,512
6,088
6,503
6,500
10,380
10,376
10,404
9,361
1.31
1.23
1.32
1.32
1.31
2.08
2.08
1.94
2.08
2.08
3.31
3.30
3.08
3.30
3.29
5.26
5.25
5.27
4.74
5.32
7.81
7.52
8.02
8.15
8.20
11.60
11.20
11.90
12.10
11.90
18.50
18.90
18.00
18.90
19.20
29.50
30.10
28.90
30.10
31.10
46.80
47.60
47.60
43.40
49.20
4.47
4.82
4.39
4.39
4.47
2.68
–
3.05
2.73
2.81
14.70
15.80
14.40
14.40
14.70
4.16
4.27
4.13
3.99
4.16
2.52
2.61
2.71
2.61
2.53
1.59
1.64
1.70
1.64
1.64
13.60
14.00
13.50
13.10
13.60
8.28
8.56
8.88
8.56
8.30
5.21
5.38
5.59
5.25
5.25
3.28
3.28
3.21
4.10
3.24
78.100
124.200
197.500
314.500
19/294
Bu or Eq
19/.0117 Bu
26/30
65/34
.0585
.0606
.060
16
14
12
10
Bu
Bu
–
Solid
.0641
.073
.071
.074
.077
.0808
.092
.0905
.0925
.094
.1019
.116
.117
.112
.126
12.4
8.79
–
7/.0242 Co
12.7
12.1
12.7
12.9
19/274
Co, Eq or Un
10.00
–
19/.0147 Bu
41/30
Solid
Bu
–
9.22
2.05
19.8
20.2
19.4
20.2
20.8
31.4
32.0
32.0
29.2
33.8
1.69
–
5.54
–
7/.0305 Bu
2.34
19/254
Co, Eq or Un
2.299
2.35
1.87
–
6.13
–
19/.0185 Cu
65/30
Solid
Bu
–
2.388
1.82
5.97
2.588
2.95
2.97
2.84
3.20
–
–
–
1.00
1.00
.98
1.25
.99
7/.0385 Co
19/.0234 Bu
37/.0169 Co
–
–
–
–
–
105/30
Bu
1.10
3.61
7/.0486 Bu
.146
.144
.169
.174
3.71
3.66
4.293
4.42
10,500
16,534
16,535
16,983
8.38
8.38
8.61
8.51
50.1
50.0
54.0
53.4
74.50
74.40
80.40
79.00
–
–
.65
.65
–
2.13
2.13
–
19/.0295 Bu or Eq
–
–
8
6
133/29
168/30
Ro 19 x 7/29
Ro 7 x 24/30
.71
.70
2.33
2.30
–
–
19/.0374 Bu
.188
.213
.222
4.775
5.41
5.64
16,800
26,576
26,818
13.33
13.60
13.49
81.1
84.1
83.2
121.00
125.00
124.00
–
.43
.44
–
1.41
1.44
.40
–
–
1.30
–
–
133/27
266/30
Ro 19 x 7/27
Ro 7 x 38/30
133/25
420/30
665/30
Ro 19 x 7/25
Ro 7 x 60/30
Ro 19 x 35/30 .338
.257
.270
6.53
26,600
42,615
42,000
21.61
21.29
33.72
135.0
140.0
213.0
201.00
208.00
317.00
.29
.28
.18
.95
.92
.59
–
–
–
–
–
–
4
2
6.850
8.59
(1) Bu - Bunched; Co - Concentric; Eq - Equilay; Ro - Rope; Un - Unilay
(2) Typical DC resistance values for uninsulated wires. Multiply by 1.04 for typical values after insulation
(3) Values are for tinned, heavy tinned, prefused, overcoated or topcoated conductors
(4) Does not meet UL conductor stranding requirements
200
Technical Information
Electronics
Cable Design Equations—Braid Shield
P
D
d
U
e
BRAID ANGLE:
BRAID PICKS PER INCH:
(D-+-2e) P
2
C
(C) (tan U)
2 (M)
U= tan-1
, DEGREES
P =
, PICKS/INCH
BRAID SHIELD DC RESISTANCE:
BRAID SHIELD WEIGHT:
rdc
Rdc = cos
, /kft
(n) (C) (I)
(n) (C) (cos U)
W =
, LBS/M FT
cos U
% Coverage: %C = (2F - F2) x-100
where:
% Coverage Factor
D
d
C
e
P
= diameter under shield, inches
for Common Coverage:
= diameter of center conductor, inches
= number of carriers
F
% Coverage
0.368
0.409
0.453
0.500
0.553
0.617
60
65
70
75
80
85
= diameter of end
= pick (measured in picks per linear inch)
= braid angle, degrees
U
W
n
= weight of shield, lbs/M ft
= number of ends in one carrier
= weight of one end in lbs/M ft
= D + build-up of braid on one shield wall, inches
= dc resistance of the braid shield, /M ft
= dc resistance of one strand (end) of shield, /M ft
l
M
Rdc
rdc
% C = percent braid coverage
= % coverage factor
F
201
Electronics
Technical Information
Cable Design Equations—Coaxial Cable
COAXIAL CABLE CAPACITANCE:
COAXIAL CABLE VELOCITY OF PROPAGATION:
7.36ε
100
=
,
V =
p
, %
C
pF/ft
ε1/2
LOG D
( )
fd
COAXIAL CABLE INDUCTANCE:
COAXIAL CABLE TIME DELAY:
t = 1.016 ε1/2, nsec/ft
D
L = 0.140 LOG
, µH/ft
d
( fd )
COAXIAL CABLE IMPEDANCE:
COAXIAL CABLE CUTOFF FREQUENCY:
7.50
138
D
f
=
, GHz
Z =
o
LOG
co
( fd ),
ε1/2
ε
1/2 (D + fd)
where:
C = capacitance, pF/ft
Z
V
= characteristic impedance,
= velocity of propagation, %
= time delay, nsec/ft
o
p
ε = insulation dielectric constant (see table below)
D = diameter under the shield, inches
d = diameter of the center conductor, inches
L = inductance, µH/ft
t
f
d
co
= cutoff frequency, GHz
f = strand factor (see Table II, page 194)
ε
MATERIAL
POWER FACTOR, PF
FEP Teflon® (Cellular)
FEP Teflon® (Solid)
PE (Cellular)
PE (Solid)
PE (Semi-Solid)
0.0002
0.0003
0.0003
0.0003
0.0003
1.40
2.10
1.56
2.26
1.29
202
Technical Information
Electronics
Cable Design Equations—Balanced Pair
CAPACITANCE (UNSHIELDED TWISTED PAIR):
IMPEDANCE (UNSHIELDED TWISTED PAIR):
2.2 ε
1016 1/2
C =
, pF/ft
Z =
o
,
( )
C
1.3 D
LOG
(f) (d)
CAPACITANCE (SHIELDED TWISTED PAIR):
IMPEDANCE (SHIELDED TWISTED PAIR):
3.7 ε
276
1.2 (D)
(f) (d)
C =
, pF/ft
Z =
o
LOG
,
ε1/2
( )
1.2 D
LOG
(f) (d)
IMPEDANCE (OVERALL SHIELDED & CABLED):
CAPACITANCE (OVERALL SHIELDED & CABLED):
347
1.5 (D)
(f) (d)
2.9 ε
Z =
o
LOG
,
C =
, pF/ft
ε1/2
( )
1.5 D
LOG
(f) (d)
where:
C = mutual capacitance, pF/ft
ε
f
= insulation dielectric constant (see Table I)
= stranding factor (see Table II)
d
= diameter of the conductor, inches
D = diameter over the insulation, inches
= characteristic impedance
Z
o
TABLE I
TABLE II
ƒ
NO. OF STRANDS
1
DIELECTRIC CONSTANTS & Vp OF INSULATIONS
1.000
0.939
0.970
0.980
0.985
0.988
Vp, %
ε
MATERIAL
™
ECTFE (Halar
FEP
)
7
2.60
2.15
2.15
5.00
3.60
7.70
2.29
2.25
6.50
4.0
63
68
68
45
53
36
66
67
39
50
45
50
57
69
45
69
62
19
37
61
91
PFA Teflon®
PVC
PVC (Semi-rigid)
™
™
PVDF (Kynar , SOLEF
)
Polyethylene
Polypropylene
Polyurethane
Rubber, butyl
Rubber, natural
Rubber, SBR
Rubber, silicone
TFE Teflon®
TPE
5.0
4.0
3.1
2.1
5.0
2.10
2.6
Teflon®
Tefzel®
203
Electronics
Technical Information
Engineering Prefixes
MULTIPLYING FACTOR
PREFIX
tera
SYMBOL
SCIENTIFIC
CONVENTIONAL
1,000,000,000,000
T
G
M
k
1012
giga
109
1,000,000,000
mega
kilo
106
1,000,000
103
1,000
hecto
deca
deci
h
102
100
da
d
101
10
10-1
10-2
10-3
10-6
10-9
10-12
10-15
10-18
0.1
centi
milli
c
0.01
m
µ
0.001
micro
nano
pico
0.000001
n
0.000000001
0.000000000001
0.000000000000001
0.000000000000000001
p
femto
atto
f
a
204
Technical Information
Electronics
Glossary
Abrasion Resistance: Resistance to surface
wear.
Ampere: The unit of current. One ampere is the
current flowing through one ohm of resistance at
one volt potential.
Analog: A signaling format that uses continuous
physical variables such as voltage amplitude or
frequency variations to transmit information.
Anneal: Relief of mechanical stress through heat
and gradual cooling. Annealing copper renders
it less brittle.
Annular Conductor: A number of wires stranded
in three reversed concentric layers around a
core.
Annunciator: A signaling device, usually electri-
cally operated, that gives an audible or visual
signal (or both) when energized.
Anti-Oxidant: A substance which prevents or
slows down oxidation of material exposed to air.
Appliance Wire and Cable: A classification
covering insulated wire and cable for internal
wiring of appliances and equipment.
Belted-Type Cable: Multiple conductor cable
having a layer of insulation over the assembled
insulated conductors.
AC Alternating Current (a.c.): Current in which
the charge-flow periodically reverses and is
Bend Loss: A form of increased attenuation
caused by (1) having an optical fiber curved
around a restrictive radius of curvature or (2)
microbends caused by minute distortions in the
fiber imposed by externally induced forces.
Bend Radius: Radius of curvature that a fiber
optic or metallic cable can bend without any
adverse effects.
represented by: I = l cos (2-f +-f) where, I is the
8
current, l is the amplitude, f the frequency, f the
8
phase angle.
Accelerated Aging: A test that attempts to
duplicate long-time environmental aging in
comparatively short time spans.
Accelerator: A chemical additive which hastens a
chemical reaction under specific conditions.
Accordion: (1) A retractile cable with a series of
equally-spaced transverse folds. (2) A connec-
tor contact with a “Z” shaped flat spring to
permit high deflection without overstress.
Adapter: A device that enables any or all of
the following 1) different sizes or types of
plugs to mate with one another or to fit into a
telecommunications outlet/connector; 2) the
rearrangement of leads; 3) large cables with
numerous wires to fan out into smaller groups of
wires, 4) interconnection between cables.
Adhesive Bonded: Cables bonded by adding
an adhesive coating to the surface of the
cable components, then joining and curing the
adhesive to form a cable. See Bonded Cable.
Administration: The method for labeling,
Bifilar: A winding made non-inductive by winding
together (as one wire) two wires carrying current
in opposite directions.
Billion Conductor Feet (BCF): A quantity derived
by multiplying the number of conductors in a
cable by the amount of cable. Usually used to
indicate plant capacity or an annual requirement.
Bimetallic Wire: A wire formed of two different
metals joined together (not alloyed). It can
include wire with a steel core clad wire, or plated
or coated wire.
Arc Resistance: The time required for an arc to
establish a conductive path in a material.
Armored Cable: A cable provided with a wrap-
ping of metal for mechanical protection.
Attenuation: The decrease in magnitude of the
power of a signal in transmission between
points. Attenuation is usually measured in
Binder: A spirally served tape or thread used for
holding assembled cable components in place
awaiting subsequent manufacturing operations.
Binding Post: A device for clamping or holding
electrical conductors in a rigid position.
decibels per unit length at a specific frequency. Bit: One binary (0 or 1) digit.
identification, documentation and usage needed Attenuation to Crosstalk Ratio (ACR): The
Blown Jacket: Outer cable covering applied by
controlled inflation of the cured jacket tube then
pulling the cable through it.
to implement moves, additions and changes of
the telecommunications infrastructure.
Admittance: The measure of the ease with which
an alternating current flows in a circuit. The
reciprocal of impedance.
difference between attenuation and crosstalk,
measured in dB, at a given frequency. Important
characteristic in networking transmission to
assure that signal sent down a twisted pair
is stronger at the receiving end, after being
attenuated, than are any interference signals
imposed on that same pair by crosstalk from
other pairs, represented by NEXT.
Bond Strength: Amount of adhesion between
bonded surfaces, e.g. in cemented ribbon cable.
Bondable Wire: An insulated wire treated to
facilitate adherence to materials such as potting
compounds. Also, magnet wires used in making
coils when bonding the turns together is desired.
Bonded Cable: Cable consisting of pre-insulated
conductors or multiconductor components
laid-in parallel and bonded into a flat cable.
See Solvent-Bonded; Adhesive-Bonded; Film-
Bonded.
Aerial Cable: A cable suspended in the air on
poles or other overhead structure.
Aging: The change in properties of a material with
time under specific conditions.
Audio Frequency: The range of frequencies
audible to the human ear. Usually 20-20,000 Hz.
Backbone: A facility (e.g. pathway, cable or
conductors) between telecommunications
closets or floor distribution terminals, the
entrance facilities and the equipment rooms
within or between buildings.
Air Core Cable: A cable in which the interstices
in the cable core are not filled with a moisture
barrier.
Air-Handling Plenum: A designated area, closed
or open, used for environmental air.
Bonded Construction: An insulation construction
in which the glass braid and nylon jacket are
bonded together.
Air Spaced Coaxial Cable: One in which air is
essentially the dielectric material. A spirally
wound synthetic filament, beads or braided
Backbone Cable or Wire: Cable or wire found in
the backbone; see Backbone.
Bonding: The permanent joining of metallic parts
to form an electrically conductive path that will
assure electrical continuity and the capacity to
conduct safely any current likely to be imposed
on it.
filaments may be used to center the conductor. Balanced Line: A cable having two identical
All-Rubber Cable: A cable in which all interstices
between conductors are filled with rubber
compound.
conductors which carry voltages opposite in
polarity and equal in magnitude with respect to
ground.
Balun: A device for matching an unbalanced
coaxial transmission line to a balanced two-wire
system.
Alligator Clip: A mechanical device shaped like
alligator jaws used as a temporary connection
on the end of interconnections wire.
Booster: A device inserted into a line (or cable) to
increase the voltage.
Boot: (1) Protective covering over a cable, wire
or connector in addition to the normal jacketing
or insulation. (2) A form placed around wire
termination of a multiple-contact connector to
contain the liquid potting compound before it
hardens.
Alloy: A metal formed by combining two or more Band Marking: A continuous circumferential band
different metals to obtain desirable properties.
Aluminum Conductor: An aluminum wire or
group of wires not suitably insulated to carry
electrical current.
applied to a conductor at regular intervals for
identification.
Banded Cable: Two or more cables banded
together by stainless steel strapping.
Bandwidth: A continuous range of frequencies
extending between two limiting frequencies.
Also referred to as a frequency band.
Barrel-Packed: Method of coiling into a fiber
drum for shipment.
Aluminum-Steel Conductor: A composite
conductor made up of a combination of
aluminum and steel wires.
Braid: A fibrous or metallic group of filaments
interwoven in cylindrical form to form a covering
over one or more wires.
Braid Angle: The smaller of the two angles
formed by the shielding strand and in the axis of
the cable being shielded.
Braid Carrier: A spool or bobbin on a braid
which holds one group of strands or filaments
consisting of a specific number of ends. The
carrier revolves during braiding operations.
Ambient Temperature: The temperature of a
medium (gas or liquid) surrounding an object.
American Wire Gauge (AWG): The standard
system used for designating wire diameter. The
lower the AWG number, the larger the diameter.
Also called the Brown and Sharpe (B&S) wire
gauges.
Baseband: In data transmission, the use of a
dedicated end-to-end connection to carry a
single channel only.
Beaded Coax: Coaxial cable with a dielectric
consisting of beads made of various materials.
Belt: Number of layers of insulation on a conduc-
tor, or number of layers of jacket on a cable.
Ampacity: See Current Carrying Capacity.
205
Electronics
Technical Information
Glossary
Braid Ends: The number of strands used to make Cable: A stranded conductor with or without
Carrier: The woven element of a braid consisting
of one or more ends (strands) which creates the
interlaced effect. Also, a spindle, spool, tube, or
bobbin (on a braiding machine) containing yarn
or wire, employed as a braid.
Cellular Plastics: Expanded or “foam,” consists
of individual closed cells of inert gas suspended
in a plastic medium, resulting in a desirable
reduction of the dielectric constant.
up one carrier. The strands are wound side by
side on the carrier bobbin and lie parallel in the
finished braid.
insulation and other coverings (single-conductor
cable), or a combination of conductors (multiple-
conductor cable). In fiber optics, a jacketed
fiber or jacketed bundle in a form which can be
terminated.
Braiding Machine: Machine used to apply braids
to wire and cable and to produce braided
sleeving and braids for tying or lacing purposes. Cable Assembly: Typically, the cable and
Braiding machines are identified by the number
of carriers.
associated connectors; ready to install.
Cable Clamp: A device used to give mechanical
Breakdown (Puncture): A disruptive discharge
through the insulation.
support to the wire bundle or cable at the rear of Central Office: The place where communications
a plug or receptacle.
common carriers terminate customer lines and
locate switching equipment that interconnects
those lines.
Certificate of Compliance (C of C): A written
statement; normally generated by a quality
control department, which states that the
product being shipped meets customer’s
specifications.
Certified Test Report (CTR): A report reflecting
actual test data on the cable shipped. Tests
are normally conducted by the quality control
department, and show that the product being
shipped meets the required test specifications.
Characteristic Impedance: The impedance that,
when connected to the output terminals of a
transmission line of any length, makes the line
appear indefinitely long.
Breakdown Voltage: The voltage at which the
insulation between two conductors breaks
down.
Cable Clamp Adapter: A mechanical adapter that
attaches to the rear of a plug or receptacle to
allow the attachment of a cable clamp.
Cable Core: The portion of an insulated cable
lying under a protective covering.
Breakout: The point at which a conductor
or group of conductors breaks out from a
multiconductor cable to complete circuits at
various points along the main cable.
Bridge: A device used to expand a local area
Cable Core Binder: A wrapping of tapes or cords
around the conductors of a multiple-conductor
cable used to hold them together.
network by forwarding frames between data link Cable Filler: The material used in multiple-
layers.
conductor cables to occupy the interslices
formed by the assembly of the insulated
conductors, thus forming a cable core.
Cable Rack: The vertical or horizontal open
support (usually made of aluminum or steel) that
is attached to a ceiling or wall.
Bridged Tap: The multiple appearances of the
same cable pair at several distribution points.
British Standard Wire Gauge: A modification
of the Birmingham Wire Gauge and the legal
standard of Great Britain for all wires. Also
known as Standard Wire Gauge (SWG), New
British Standard (NBS), English Legal Standard
and Imperial Wire Guide.
Cable Sheath: The overall protective covering
applied to cables.
Chlorosulfonated Polyethylene (CSPE):
A
Cable Tray: A ladder, trough, solid-bottom or
channel raceway system intended for, but not
limited to, the support of telecommunications
media (e.g., cable).
rubbery polymer used for insulations and
jackets. Manufactured by E.l. DuPont under the
trade name of Hypalon®.
Broadband: In data transmission, the use of a
carrier signal, rather than direct modulation, to
carry several simultaneous channels.
Buffer: (fiber optic) A soft material which
mechanically isolates individual fibers in a fiber
optic cable or bundle from small geometrical
irregularities, distortions or roughness of
adjacent surfaces.
Cigarette Wrap: Tape insulation wrapped
longitudinally instead of spirally over a
conductor.
Cable Vulcanizer: Compression molding machine
used to repair cable jacketing that has had a
part removed for splicing, for adding connectors Circuit: A complete path over which electrons
or other devices or for replacing damaged
sections.
can flow from the negative terminals of a voltage
source through parts and wires to the positive
terminals of the same voltage source.
Circuit Sizes: A popular term for building wire
sizes 14 through 10 AWG.
Circular Mil: The area of a circle one mil (.001") in
diameter; 7.854 x 10-7 sq. in. Used in expressing
wire cross sectional area.
Cladding: Method of applying a layer of metal
over another metal whereby the junction of
the two metals is continuously welded. In fiber
optics, a sheathing intimately in contact with
the core of a higher refractive index material
which serves to provide optical insulation and
protection to the reflection interface.
Closed End Splice: An insulated splice in which
two or more wires overlap and enter the splice
from the same end of the barrel.
Closet, Telecommunications: An enclosed space
for housing telecommunications equipment,
cable terminations and cross-connect cabling.
The closet is the recognized location of the
cross-connect between the backbone and
horizontal facilities.
Coaxial Cable: A cable consisting of two
cylindrical conductors with a common axis,
separated by a dielectric.
Coaxial Connector: A connector that has a
coaxial construction and is used with coaxial
cable.
Buffing Stripper: A motorized device for
removing flat cable insulation by means of
buffing wheels that melt the insulation and
brush it away from the conductors. Also called
Abrasion Stripper.
Cabling: (1) A combination of all cables, wire,
cords and connecting hardware. (2) Twisting
together two or more insulated conductors
by machine to form a cable. In fiber optics, a
method by which a group or bundle of fibers is
mechanically assembled.
Cabling Factor: Used in the formula for
calculating the diameter of an unshielded,
unjacketed cable. D = Kd, where D is the cable
diameter, K is the factor and d is the diameter of
one insulated conductor.
Campus: The building and grounds of a complex
(e.g. a university, college, industrial park or
military establishment).
Building Entrance Area: See Entrance Room or
Space, Telecommunications.
Building Wire: Wire used for light and power, 600
volts or less, usually not exposed to outdoor
environment.
Bunched Stranding: A group of strands
twisted together in a random manner and the
same direction without regard to geometric
arrangement of specific strands.
Buncher: A machine that twists wires together in Canadian Standards Association (CSA): A non-
random arrangement.
profit independent organization which operates
a listing service for electrical and electronic
materials and equipment. The Canadian
counterpart of the Underwriter’s Laboratories.
Bundle: (fiber optic) A number of fibers grouped
together, usually carrying a common signal.
Buried Cable: A cable installed directly in the
earth without use of underground conduit. Also Capacitance: The ratio of the electrostatic charge
called “direct burial cable.”
on a conductor to the potential difference
between the conductors required to maintain
that charge.
Capacitance, Direct: The capacitance measured
from one conductor to another conductor
through a single insulating layer.
Bus: Wire used to connect two terminals inside of
an electrical unit.
Bushing: A mechanical device used as a lining
for an opening to prevent abrasion to wire and
cable.
Butt: Joining of two conductors end-to-end, with Capacitance, Mutual: The capacitance between
no overlap and with the axes in line.
two conductors (typically of a pair) with all other
conductors, including shield, short circuited to
ground.
Butt Splice: A splice wherein two wires from
opposite ends butt against each other, or
against a stop, in the center of a splice.
Butt Wrap: Tape wrapped around an object or
conductor in an edge-to-edge condition.
Byte: Typically a group of eight binary digits.
Coherent Source: (fiber optic) A light source
which emits a very narrow, unidirectional beam
of light of one wavelength (monochromatic).
Coil Effect: The inductive effect exhibited by a
spiral-wrapped shield, especially above audio
frequencies.
Carolprene®: Proprietary rubber compound.
206
Technical Information
Electronics
Glossary
Cold Flow: Permanent deformation of the
insulation due to mechanical force of pressure
(not due to heat softening).
Continuity Check: A test to determine whether
electrical current flows continuously throughout
the length of a single wire or individual wires in
a cable.
Creepage Path: The path across the surface of a
dielectric between two conductors.
Creepage Surface: An insulating surface which
provides physical separation as a form of
insulation between two electrical conductors of
different potential.
Color Code: A color system for wire or circuit
identification by use of solid colors, tracers,
braids, surface printing, etc.
Continuous Vulcanization: Simultaneous
extrusion and vulcanization of rubber-like wire
coating materials.
Commercial Building: A building or portion
thereof, that is intended for office use.
Common Axis Cabling: In multiple cable
constructions, a twisting of all conductors
about a “common axis” to result in smaller
diameter constructions. Tends to result in
greater susceptance to electromagnetic and
electrostatic interference.
Compact Conductor: Stranded conductor rolled
to deform the round wires to fill the normal
interstices between the wires in a strand.
Composite (Clad) Wire: A wire having a core of
one metal with a fused outer shell of different
metals.
Composite Conductor: Two or more strands of
different metals assembled and operated in
parallel.
Compound: An insulating or jacketing material
made by mixing two or more ingredients.
Compression Cable: A pipe type cable in which
the pressure medium is separated from the
insulation by a membrane or sheath.
Concentric: A central core surrounded by one or Cord, Telecommunications: A cable using
more layers of helically wound strands in a fixed
round geometric arrangement.
Crimp: Act of compressing a connector barrel
around a cable in order to make an electrical
connection.
Contrahelical: Cable spiralling in an opposite
direction than the preceding layer within a wire
or cable.
Control Cable: A multi-conductor cable made for
operation in control of signal circuits.
Controlled Impedance Cable: Package of two or
more insulated conductors where impedance
measurements between respective conductors
are kept essentially constant throughout the
entire length.
Crimp Termination: Connection in which a
metal sleeve is secured to a conductor by
mechanically crimping the sleeve with pliers,
presses or automated crimping machines.
Cross-Connect: A facility enabling the termination
of cable elements and their interconnection,
and/or cross-connection, primarily by means of
a patch cord or jumper.
Copolymer: A compound resulting from the
polymerization of two different monomers.
Copper-Clad: Steel with a coating of copper
welded to it before drawing as opposed to
copper-plated. Synonymous with Copperweld.
Copperweld: The trade name of Flexo Wire
Division (Copperweld Steel Corp.) for their
copper-clad steel conductors.
Cross-Linked: Inter-molecular bonds between
long-chain thermoplastic polymers by chemical
or electron bombardment means. The properties
of the resulting thermosetting material are
usually improved.
Crosstalk: Undesired electrical currents in
conductors caused by electromagnetic or
electrostatic coupling from other conductors or
from external sources. Also, leakage of optical
power from one optical conductor to another.
CSA: Canadian Standards Association.
C-SJ: Same as SJ except extra-flexible conductor.
C-SJO: Same as SJO except extra-flexible
conductor.
Cord: A small, flexible insulated cable.
Cord Set: Portable cords fitted with a wiring
device at one or both ends.
stranded conductors for flexibility, as in
distribution cords or line cords. Line cords can
also use tinsel conductors.
Concentric-Lay Cable: A concentric-lay
conductor, or a multiple-conductor cable
composed of a central core surrounded by
one or more layers of helically laid insulated
conductors.
Cure: To change the physical properties of a
material by chemical reaction.
Curing Cycle: The time, temperature and pressure
required for curing.
Core: In cables, a component or assembly of
components over which other materials are
applied, such as additional components, shield,
sheath or armor. In fiber optics, the transparent Curl: The degree to which a wire tends to form a
Concentric Strand: A strand that consists of a
central wire or core surrounded by one or more
layers of spirally laid wires.
glass or plastic section with a high refractive
index through which the light travels by internal
reflections.
circle after removal from a spool. An indication
of the ability of the wire to be wrapped around
posts in long runs.
Concentricity: The measurement of the location
of the center of the conductor with respect to
the geometric center of the circular insulation.
Corona: A discharge due to ionization of air
around a conductor due to a potential gradient
exceeding a certain critical value.
Current: The rate of transfer of electricity.
Practical unit is the ampere which represents the
transfer of one coulomb per second. In a simple
circuit, current (I) produced by a cell or
electromotive force (E) when there is an external
resistance (R) and internal resistance (r)
Conductance: The ability of a conductor to carry Corona Resistance: The time that the insulation
an electric charge. The ratio of the current flow
to the potential difference causing the flow. The
reciprocal of resistance.
will withstand a specified level of field-intensified
ionization that does not result in the immediate
complete breakdown of the insulation.
E
R + r
is:
I =
Conductivity: The capacity of a material to
carry electrical current—usually expressed as
a percentage of copper conductivity (copper
being 100%).
Corrosion: The destruction of the surface of a
metal by chemical reaction.
Current Carrying Capacity: The maximum
current an insulated conductor can safely carry
without exceeding its insulation and jacket
temperature limitations.
Coupling Loss: (fiber optic) Signal losses due to
small differences in numerical aperture, core
diameter, core concentricity and tolerances in
Conductor: A wire (or combination of wires not
insulated from one another) suitable for carrying
electric current.
splicing connectors when two fibers are aligned. Customer Premises: Building(s) with grounds and
Also known as Splicing Loss and Transfer Loss.
appurtenances (belongings) under the control of
the customer.
Conduit: A rigid or flexible metallic or nonmetallic Coupling Ring: A device used on cylindrical
raceway of circular cross-section through which
cables can be pulled or housed.
connectors to lock plug and receptacle together. Cut-Through Resistance: The ability of a material
Coverage: The calculated percentage which
defines the completeness with which a metal
braid covers the underlying surface. The
higher percentage of coverage, the greater the
protection against external interference.
Covering: Textile braid or jacket of rubber,
plastics or other materials applied over wire and
cables to provide mechanical protection and
identification.
to withstand mechanical pressure, usually a
sharp edge or small radius, without separation.
Cycle: The complete sequence including reversal
of the flow of an alternating electric current.
Decibel (dB): A unit to express differences of
power level. Used to express power gain in
amplifiers or power loss in passive circuits or
cables.
Delay Line: A cable made to provide very low
velocity of propagation with long electrical delay
for transmitted signals.
Demarcation Point: A point where the operational
control or ownership changes.
Connecting Hardware: A device providing
mechanical cable terminations.
Connector: A device used to provide rapid
connect/disconnect service for electrical cable
and wire terminations.
Contact: The part of a connector which actually
carries the electrical current, and are touched
together or separated to control the flow.
Contact Inspection Hole: A hole in the cylindrical Crazing: The minute cracks on the surface of
rear portion of contact used to check the depth
to which a wire has been inserted.
plastic materials.
Creep: The dimensional change with time of a
material under load.
Contact Size: The largest size wire which can
be used with the specific contact. Also, the
diameter of the engagement end of the pin.
Creepage: The conduction of electricity across
the surface of a dielectric.
207
Electronics
Technical Information
Glossary
Depth of Crimp: Thickness of the crimped portion Dissipation Factor: The tangent of the loss angle Electromagnetic Induction: The production of a
of a connector measured between two opposite
points on the crimped surface.
of the insulating material. (Also referred to as
loss tangent, tan d, and approximate power
factor.)
voltage in a coil due to a change in the number
of magnetic lines of forces (flux linkages)
passing through the coil.
Electromagnetic Interference (EMI): The
interference in signal transmission or reception
resulting from the radiation of electrical and
magnetic fields. Synonym: Radio Frequency
Interference.
Derating Factor: A factor used to reduce the
current carrying capacity of a wire when used in Distribution Cable: In telecommunications and
environments other than that for which the value
was established.
CATV systems, the transmission cable between
the distribution amplifier and the drop wire.
Detector: (fiber optic) A device that picks up light Distribution Frame: A structure with terminations
from fiber and converts the information into an
electrical signal.
for connecting the permanent cabling of a
facility in such a manner that interconnection or Electromotive Force (e.m.f.): Pressure or
Device, As Related to a Work Station: An item
such as a telephone, personal computer or
graphic or video terminal.
cross-connections may be readily made.
Disturbed Conductor: A conductor that receives
energy generated by the field of another
conductor or an external source such as a
transformer.
Drain Wire: In a cable, the uninsulated wire laid
over the component or components and used
as a ground connection.
voltage. The forces which cause current to flow
in a circuit.
Electronic Wire and Cable: A length of
conductive or semiconductive material used in
an electronic application.
Device, As Related to Protection: A protector, a
protector mount, a protector unit or a protector
module.
Electrostatic: Pertaining to static electricity,
or electricity at rest. An electric charge, for
example.
Dielectric: An insulating medium which
intervenes between two conductors and permits
electrostatic attraction and repulsion to take
place across it.
Draw Feed Stock: Rod or wire that is
subsequently drawn to a smaller size.
Drawing: In wire manufacture, pulling the
metal through a die or series of dies to reduce
diameter to a specified size.
Elongation: The fractional increase in the length
of a material stressed in tension.
Dielectric Breakdown: The voltage required to
cause an electrical failure or breakthrough of the
insulation.
Embossing: A marker identification by means of
thermal indentation leaving raised lettering on
the sheath material of cable.
Dielectric Constant (K): The ratio of the
capacitance of a condenser with dielectric
between the electrodes to the capacitance
when air is between the electrodes. Also called
Permittivity and Specific Inductive Capacity.
Dielectric Loss: Power dissipated in an insulating
medium as the result of the friction caused by
molecular motion when an AC electric field is
applied.
Drop Ceiling: See False Ceiling.
Emergency Overload: Load which occurs when
larger than normal currents are carried through a
cable or wire over a certain period of time.
Enameled Wire: A conductor with a baked-
on enamel film insulation. In addition to
magnet wire, enameled insulation is used on
thermocouple type wires and other wires.
Ends: In braiding, the number of essentially
parallel wires of threads on a carrier.
Energize: To apply rated voltage to a circuit or
device in order to activate it.
Drop Wire: In telecommunications and CATV
systems, the transmission cable from the
distribution cable to a dwelling.
Dual Coaxial Cable: Two individually insulated
conductors laid parallel or twisted and placed
within an overall shield and sheath.
Duct: 1) A single enclosed raceway for wires or
cables. See also Conduit, Raceway; 2) a single
enclosed raceway for wires or cables usually
used in soil or concrete, 3) an enclosure in which
Dielectric Strength: The voltage which an
insulation can withstand before breakdown
occurs. Usually expressed as a voltage gradient
(such as volts per mil).
air is moved. Generally part of the HVAC system Entrance Facility, Telecommunications: An
of a building.
entrance to a building for both public and private
network service cables (including antennae)
including the entrance point at the building wall
and continuing to the entrance room or space.
Entrance Point, Telecommunications: The
point of emergence of telecommunications
conductors through an exterior wall, a concrete
floor slab or from a rigid metal conduit or
intermediate metal conduit.
Entrance Room or Space, Telecommunications:
A space in which the joining of inter- or intra-
building telecommunications backbone facilities
takes place. An entrance room may also serve
as an equipment room.
Dielectric Test: A test in which a voltage higher
than the rated voltage is applied for a specified
Duplex: Two way data transmission on a four-wire
transmission line or two fiber.
time to determine the adequacy of the insulation Duplex Cable: (1) A cable composed of two
under normal conditions.
insulated single-conductor cables twisted
together. (2) A cable composed of two fibers,
typically 62.5/125 mm multimode, placed in
parallel under a thermoplastic sheath.
Digital: Transmission data representative by
discrete characters.
Dip Coating: An insulating coating applied to the
conductor by passing the conductor through an Duplex Parallel: Typically used in the
applicator containing liquid insulating medium.
Direct Burial Cable: A cable installed directly in
the earth.
thermocouple industry to denote two parallel
conductors of dissimilar metals insulated in
parallel without twist and jacketed. Commonly
applied to thermocouple grades and extension
wires.
Eccetricity: Like concentricity, a measure of the
center of a conductor’s location with respect
to the circular cross section of the insulation.
Expressed as a percentage of displacement of
one circle within the other.
Eddy Current: Circulating currents induced in
conducting materials by varying magnetic fields.
Elastomer: A rubber or rubber-like material
which will stretch repeatedly to 200 percent or
more and return rapidly and with force to its
approximate original shape.
Direct Capacitance: The capacitance measured
directly from conductor to conductor through a
single insulating layer.
Equilay: More than one layer of helically laid wires
with the direction of lay reversed for successive
layers, but with the length of lay the same for
each layer.
Direct Current (d.c.): An electric current which
flows in only one direction.
Direct Current Resistance (DCR): The resistance
offered by any circuit to the flow of direct
current.
Equipment Room, Telecommunications:
A
centralized space for telecommunications
equipment that serves the occupants of the
building. An equipment room is considered
distinct from a telecommunications closet
because of the nature of complexity or the
equipment.
Direction of Lay: The lateral direction in which
the strands of a conductor run over the top of
the cable conductor as they recede from an
observer looking along the axis of the conductor
or cable. Also applies to twisted cable.
Discrete Wiring: Wire or wires having distinct
identity and purpose.
Electro-Tinned: Electrolytic process of tinning
wire using pure tin.
Electrode: A conductor through which a current
enters or leaves a nonmetallic conductor.
Etched Wire: A process applied to fluoroplastic
wire in which the wire is passed through a
sodium bath to create a rough surface to allow
epoxy resin to bond the fluoroplastic.
Exit Angle: The angle between the output
radiation vectors and the axis of the fiber or fiber
bundle.
External Interference: The effects of electrical
waves or fields which cause sounds other than
the desired signal. Static.
Dispersion: (fiber optic) The variation of the
refractive index of a material with wavelength,
causing light of different wavelengths to travel at Electromagnetic Coupling: Energy transfer by
different velocities in the material.
means of a varying magnetic field.
Electromagnetic Field: A rapidly moving electric
field and its associated moving magnetic field.
Disruptive Discharge: A sudden, large increase
in current through an insulation medium due to
the complete failure of the medium under the
electrostatic stress.
208
Technical Information
Electronics
Glossary
External Wiring: Electronic wiring which
interconnects subsystems within the system.
Extruded Cable: Cable with conductors which
are uniformly insulated and formed by applying
a homogeneous insulation material in a
continuous extrusion process.
Extrusion: Method of continuously forcing plastic,
rubber, or elastomer material through an orifice
to apply insulation or jacketing over a conductor
or cable core.
Filled Cable: A telephone cable construction in
which the cable core is filled with a material that
will prevent moisture from entering or passing
through the cable.
Fused Spiral Tape: A PTFE insulated hookup
wire. The spiral wrapped conductor is passed
through a sintering oven where overlaps are
fused together.
Filler: (1) A material used in multiconductor
cables to occupy large interstices formed by the
assembled conductors. (2) An inert substance
Gain: The increase of voltage, current or power
over a standard or previous reading. Usually
expressed in decibels.
added to a compound to improve properties or Galvanometer: An instrument for detecting or
decrease cost.
measuring small electrical current.
Film: A thin plastic sheet.
Gas-Filled Cable: A self-contained pressure cable
in which the pressure medium is an inert gas
having access to the insulation.
False Ceiling: A ceiling that creates an area or
space between the ceiling material and the
structure above the material. Synonym: Drop
Ceiling, Suspended Ceiling.
Fine Stranded Wire: Stranded wire with
component strands of 36 AWG or smaller.
Firestop: A material, device or assembly of parts Gauge: A term used to denote the physical size
installed in a cable system in a fire-rated wall
or floor to prevent passage of flame, smoke or
gasses through the rated barrier.
Flame Resistance: The ability of a material not
to propagate flame once the heat source is
removed.
of a wire.
Farad: A unit of electrical capacity.
Giga: A numerical prefix denoting one billion (109).
Gigahertz (GHz): A unit of frequency equal to one
billion hertz.
Fatigue Resistance: Resistance to metal
crystallization which leads to conductors or
wires breaking from flexing.
Gimmick: A short length of wire soldered onto
a circuit component and used as a small
adjustable capacitor.
Graded-lndex: A type of optical fiber in which
the refractive index of the core is in the form
of a parabolic curve, decreasing toward the
cladding. This type of fiber provides high
bandwidth capabilities.
Feed-Through Insulators: Insulators that carry
a metal conductor through the chassis while
preventing the “hot” lead from shorting to the
ground chassis.
Flammability: The measure of the material’s
ability to support combustion.
Flashover: A disruptive discharge around or over
the surface of a solid or liquid insulator.
Flat Braid: A woven braid of tinned copper
strands rolled flat at time of manufacture to a
specified width.
Feedback: Energy that is extracted from a high-
level point in a circuit and applied to a lower
level. Positive feedback reduces the stability of
a device and is used to increase the sensitivity
or produce oscillation in a system. Negative
feedback, also called inverse feedback,
increases the stability of a system as the
feedback improves stability and fidelity.
Feeder Cable: In telecommunication or CATV
systems, the transmission cable from the head
end (signal pickup) to the trunk amplifier. Also
called a trunk cable.
Feedthrough: (1) A conductor that connects
patterns on opposite sides of a PCB. Also
called Interfacial connection. (2) A connector
or terminal block, usually having double-ended
terminals which permit simple distribution and
bussing of electrical circuits.
Ground: A conducting connection, whether
intentional or accidental, between an electrical
circuit (e.g. telecommunications) or equipment
and the earth, or to some conducting body that
serves in place of the earth.
Ground Conductor: A conductor in a transmission
cable or line that is grounded.
Flat Cable: A cable with two smooth or
corrugated but essentially flat surfaces.
Flat Conductor: A wire having a rectangular
cross-section as opposed to a round or square
conductor.
Flat Conductor Cable: A cable with a plurality of
flat conductors.
Ground Insulation: The insulation used between
a winding and the magnetic core or other
structural parts, usually at ground potential.
Ground Loop: The generation of undesirable
current flow within a ground conductor, owing
to the circulation currents which originate from a
second source of voltage.
Flexfoil®: Proprietary aluminum laminated
shielding tapes.
Flex Life: The measurement of the ability of
a conductor or cable to withstand repeated
bending.
Flexibility: The ease with which a cable may
be bent.
Ground Plane: Expanded copper mesh which is
laminated into some flat cable constructions as
a shield.
Ferrous: Composed of and/or containing iron. A
ferrous metal exhibits magnetic characteristics.
Ferrule: A short tube used to make solderless
connections to shielded or coaxial cable.
Fiber: A thread or threadlike structure. Also, a
Flexible: That quality of a cable or cable
component which allows for bending under
the influence of outside force, as opposed to
limpness which is bending due to the cable’s
own weight.
Ground Potential: Zero potential with respect to
the ground or earth.
Hard Drawn Copper Wire: Copper wire that has
not been annealed after drawing.
single discrete element used to transmit optical Floating: Referring to a circuit which has no
(light wave) information.
connection to ground.
Harness: An arrangement of wires and cables
usually with many breakouts, which have been
tied together or pulled into a rubber or plastic
sheath, used to interconnect an electric circuit.
Hash Mark Stripe: A non-continuous helical
stripe applied to a conductor for identification.
Heat Distortion: Distortion of flow of a material or
configuration due to the application of heat.
Heat Seal: Method of sealing a tape wrap jacket
by means of thermal fusion.
Fiber Dispersion: (fiber optic) Pulse spreading
in a fiber caused by differing transit times of
various modes.
Flux: (1) The lines of force which make up an
electrostatic field. (2) The rate of flow of energy
across or through a surface. (3) A substance
used to promote or facilitate fusion.
FNC: Federal Networking Council (formerly
FRICC).
Fiber Optics: A lightwave or optical
communications system in which electrical
information is converted to light energy,
transmitted to another location through optical
Foamed Plastics: See Cellular Plastic.
fibers, and is there converted back into electrical Foil: A thin, continuous sheet of metal.
information.
Free Connector: A connector for attachment to
the free end of a wire or cable.
Fiber Tubing: A loose, crush-resistant cylinder
applied over individual fibers to provide
mechanical protection.
Heater Cord: Flexible stranded copper conductor,
cotton wrapped, with rubber insulation and
asbestos roving.
Frequency: The number of times a periodic
action occurs in a unit of time. The number of
Field: An area of influence around a magnet or
electric charge.
cycles that an electric current completes in one Helical Stripe: A continuous, colored, spiral stripe
second.
applied to a conductor for circuit identification.
Helix: Spiral winding.
Field Coil: A suitable insulated winding to be
mounted on a field pole to magnetize it.
Figure 8 Cable: An aerial cable configuration in
Frequency Response: The characteristic of a
device denoting the range of frequencies over
which it may be used effectively.
Henry: The unit of inductance.
Hertz (Hz): A term replacing cycles-per-second as
an indication of frequency.
which the conductors and the steel strand which Funnel Entry: Flared or widened entrance to a
supports the cable are integrally jacketed. A
terminal or connector wire barrel.
Heterogeneous Insulation: A cable insulating
system composed of two or more layers of
different insulating materials.
cross-section of the finished cable approximates Fuse Wire: Wire made from an alloy that melts at
the figure “eight.”
a relatively low temperature.
Filament: Fiber characterized by extreme length. Fused Coating: A metallic coating which
has been melted and solidified, forming a
metallurgical bond to the base material.
Fused Conductors: Individual strands of heavy
tinned copper wire stranded together and then
bonded together by induction heating.
209
Electronics
Technical Information
Glossary
High-Temperature Wire and Cable: Electrical
wire and cables having thermal operating
characteristics of 150°C and higher.
Infrastructure, Telecommunications:
A
Ionization Voltage (Corona Level): The minimum
value of falling rms voltage which sustains
electrical discharge within the vacuous or
gas-filled spaces in the cable construction or
insulation.
Irradiation: In insulations, the exposure of
the material to high energy emissions for the
purpose of favorably altering the molecular
structure.
Jack: A plug-in type terminal widely used in an
electronic apparatus for temporary connections.
Jacket: An outer protective sheath over primary
insulation, braids, shields, cable components or
over the cable itself. In fiber optics, a covering,
over a fiber, bundle of fibers or cable which
protects against the environment.
JAN Specification: Joint Army-Navy specification
(replaced by current Military Specifications).
Jumper: An assembly of twisted pairs without
connectors, used to join telecommunications
circuits/links at the cross connect.
Junction: A point in a circuit where two or more
wires are connected.
collection of those telecommunications
components, excluding equipment, that
together provide the basic support for the
distribution of all information within a building or
campus.
High Voltage: Generally, a wire or cable with an
operating voltage of over 600 volts.
Holding Strength: Ability of a connector to remain
assembled to a cable when under tension.
Homogeneous Insulation: A complete cable
insulation structure whose components cannot
be identified as layers of different materials.
Hook-up Wire: A wire used for low-current, low-
voltage (under 1000 volts) applications within
enclosed electronic equipment.
Horizontal Cabling: The wiring/cabling between
the telecommunications outlet/connector and
the horizontal cross-connect.
Horizontal Cross-Connect: A cross-connect
of horizontal cabling to other cabling, e.g.
horizontal, backbone or equipment.
Insertion Loss: As measure of the attenuation of
a device by determining the output of a system
before and after the device is inserted into the
system.
Insertion Tool: A small, hand-held tool used to
insert contacts into a connector.
Insulated Wire: A conductor of electricity covered
with a non-conducting material.
Insulating Joint: A device which mechanically
couples and electrically insulates the sheath and
armor of contiguous lengths of cable.
Insulation: A material having high resistance
to the flow of electric current. Often called a
dielectric in radio frequency cable.
Insulation Adhesion: The degree of tightness
of the insulation over the base conductor,
measured in terms of force required to remove a
specified length of insulation from the wire.
Insulation Crimp: The area of a terminal, splice
or contact that has been formed around the
insulation of the wire.
Hot Stamping: Method of alpha numerical
coding. Identification markings are made by
pressing heated type and marking foil into
softened insulation surfaces. See Surface
Printing.
Keying: The mechanical feature of a connector
system that guarantees correct orientation of
a connection, or prevents the connection to a
jack, or to an optical fiber adapter of the same
type intended for another purpose.
Kynar®: Pennwalt trade name for polyvinylidene
fluoride. Typically used as insulation for wire
wrap wire.
Hot Tin Dip: A process of passing bare wire
through a bath of molten tin to provide a
coating.
Hybrid Cable: An assembly of two or more cables Insulation Grip: Extended cylinders at the rear
(of the same or different types or categories)
covered by one overall sheath.
of crimp-type contacts designed to accept the
bared wire and a small length of its insulation.
Insulation Piercing: A method of crimping
whereby lances cut the insulation of the wires
and enter into the strands to make electrical
contact.
Insulation Resistance: The ratio of the applied
voltage to the total current between two
electrodes in contact with a specific insulation,
usually expressed in megΩ-M feet.
Insulation System: All of the insulation materials
used to insulate a particular electrical or
electronic product.
Hygroscopic: Capable of absorbing moisture
from the air.
Lacing and Harnessing: A method of grouping
wires by securing them in bundles of designated
patterns.
Hypalon®: DuPont’s trade name for their
chlorosulfonated polyethylene, an ozone-
resistant synthetic rubber.
Lacquer: A liquid resin or compound applied
to textile braid to prevent fraying, moisture
absorption, etc.
Impact Tool: Device used to punch new
conductor onto IDs. This tool is typically
equipped with a cutting blade for either 66 or
110 blocks.
Laminated Tape: A tape consisting of two or
more layers of different materials bonded
together.
Impedance: The total opposition that a circuit
offers to the flow of alternating current or any
Laser Diode: (fiber optic) A semiconductor diode
that, when pulsed, a laser diode emits coherent
light.
other varying current at a particular frequency. It Integral Belt: A layer of insulation or
is a combination of resistance R and reactance
semiconductive material applied by extrusion
over two or more insulated, twisted or parallel
conductors, to form a round, smooth diameter.
Interconnect: A connection scheme that provides
X, measured in Ω.
Impedance-Matching Transformer:
Launch Angle: (fiber optic) The angle between the
radiation vector and the axis of the fiber or fiber
bundle.
A
transformer designed to match the impedance
of one circuit to that of another (BALUN).
Impulse: A surge of unidirectional polarity.
Impulse Strength: The voltage breakdown of
insulation under voltage surges on the order of
microseconds in duration.
for the direct connection of individual cables to Lay: The length measured along the axis of a wire
another cable or to an equipment cable without
a patch cord.
or cable required for a single strand (in stranded
wire) or conductor (in cable) to make one
complete turn about the axis of the conductor
or cable.
Layer: Consecutive turns of a coil lying in a single
plane.
Interconnecting Cable: The wiring between
modules, between units or the larger portions of
a system.
Impulse Test: An insulation test in which the
voltage applied is an impulse voltage of
specified wave shape.
Incoherent Source: (fiber optic) A light source
which emits wide, diffuse beams of light of many
wave lengths.
Index-Matching Fluid: (fiber optic) Fluid with
refractive index same as fiber core; used to fill
air gap between fiber ends at connectors.
Index of Refraction: The ratio of light velocity in
a vacuum to its velocity in a given transmitting
medium.
Inductance: The property of a circuit or circuit
element that opposes a change in current flow,
thus causing current changes to lag behind
voltage changes. It is measured in henrys.
Inductive Coupling: Crosstalk resulting from
the action of the electromagnetic field of one
conductor on the other.
Interconnecting Wire: The physical wiring
between components (outside a module),
between modules, between units or between
larger portions of a system or systems.
Interconnection: Mechanically joining devices
together to complete an electrical circuit.
Interface: The two surfaces on the contact side
of both halves of a multiple-contact connector
which face each other when the connector is
assembled.
Leaching and Non-Leaching: In a leaching
wire, the plasticizer will migrate when exposed
to heat. A non-leaching wire will retain its
plasticizer under extreme temperature
conditions and remain flexible after baking.
Lead: A wire, with or without terminals, that
connects two points in a circuit.
Lead-Cured: A cable that is cured or vulcanized in
a metallic lead mold.
Intermediate Cross-Connect: A cross-connect
between 1st level and 2nd level backbone
cabling.
Lead Dress: The placement or routing of wire and
component leads in an electrical circuit.
Lead-in: The conductor or conductors that
connect the antenna proper to electronic
equipment.
Internal Wiring: Electronic wiring which
interconnects components, usually within a
sealed subsystem.
Leakage Current: The undesirable flow of current
through or over the surface of an insulation.
Interstices: Voids or valleys between individual
strands in a conductor or between insulated
conductors in a multiconductor cable.
210
Technical Information
Electronics
Glossary
Life Cycle: A test to determine the length of time Low-Noise Cable: Cable configuration specially
Modem: Device which places and receives data
signals over a common carrier’s communication
facility.
before failure in a controlled, usually accelerated,
environment.
constructed to eliminate spurious electrical
disturbances caused by capacitance changes or
Light Commercial Building: A building or portion
thereof that is intended for use with one to four
self-generated noise induced by either physical Modular Jack: This term is outmoded; see
abuse or adjacent circuitry.
Outlet/Connector, Telecommunications.
(1-4) non-residential exchange access lines per Low Tension: Low voltage, as applied to ignition Modular Plug: A telecommunications connector
tenant.
cable.
for wire or cords per the Part 68 Rules. A
modular plug can have 6 or 8 contact positions,
but not all the positions need be equipped with
contacts.
Light-Intensity Ratio: (fiber optic) Ratio of input
light intensity to the output light intensity.
Light Source: (fiber optic) An object capable of
emitting light. In fiber optics, the light source is
normally an LED or a laser.
Lug: Termination, usually crimped or soldered to
the conductor, with provision for screwing on to
the terminal.
m: Meter.
Modulation: A process whereby certain
characteristics of a wave, often called the
carrier, are varied or selected in accordance with
a modulating function.
Magnet Wire: Insulated wire intended for use in
windings on motor, transformer and other coils
for electromagnetic devices.
Lightguide: (fiber optic) A flexible bundle of fibers
used to transmit light.
Lightwave Communications: (fiber optic)
Communications using light to carry the
information.
Limits of Error: The maximum deviation
(in degrees of percent) of a thermocouple or
thermocouple extension wire from standard
emf-temperature to be measured.
Limpness: The ability of a cable to lay flat or
conform to a surface.
Line Balance: The degree to which the
conductors of a cable are alike in their electrical
characteristics with respect to each other, to
other conductors and to ground.
Line Drop: A voltage loss occurring between any
two points in a transmission line, due to the
resonance, reactance or leakage of the line.
Magnetic Field: The region within which a body
or current experiences magnetic force.
Magnetic Flux: The rate of flow of magnetic
energy across or through a surface (real or
imaginary).
Modulus of Elasticity: The ratio of stress to strain
in an elastic material.
Moisture Absorption: The amount of moisture,
in percentage, that a material will absorb under
specified conditions.
Magnetic Noise: Caused by change in current
level, e.g. ac powerline (creates magnetic field
around the cable) this magnetic field causes the
magnetic noise.
Main Cross-Connect: A cross-connect for 1st
level backbone cables, entrance cables and
equipment cables.
Marker Tape: A tape laid parallel to the
conductors under the sheath in a cable,
imprinted with the manufacturer’s name and the
specification to which the cable is made.
Moisture Resistance: The ability of a material to
resist absorbing moisture from the air or when
immersed in water.
Molded Plug: A connector molded on either end
of a cord or cable.
Monomer: The basic chemical unit used in
building a polymer.
Motor Lead Wire: Wire which connects to the
fragile magnet wire found in coils, transformers
and stator or field windings.
Multiconductor: More than one conductor within
a single cable complex.
Line Loss: The total of the various energy losses Master Antenna Television (MATV):
A
occurring in a transmission line.
combination of components providing multiple
Multimode Optical Fiber: An optical fiber that
will allow many bound modes to propagate. The
fiber may be either a graded-index or step-index
fiber. See also: Optical Fiber Cable.
Line Voltage: Voltage existing in a cable or circuit.
Link: An assembly of telecommunications
facilities between two points, not including
terminal equipment.
television receiver operations from one antenna
or group of antennas normally on a single
building.
Material Scattering Loss: (fiber optics) Loss
due to fluctuations in the refractive index and
to inhomogeneities in material composition and
temperature.
Multiple Conductor Cable: A combination of
two or more conductors cabled together and
insulated from one another and from sheath or
armor where used.
Listed: Equipment included in a list published
by an organization, acceptable to the authority
having jurisdiction, that maintains periodic
inspection of production of listed equipment,
and whose listing states either that the
equipment or material meets appropriate
Media, Telecommunications: Wire, cable or
conductors used for telecommunications.
Megarad: A unit for measuring radiation dosage.
Multiple Conductor Concentric Cable: An
insulated central conductor with one or more
tubular stranded conductors laid over it
concentrically and insulated from one another.
Multiplexing: Simultaneous transmission of two
or more messages over the same cable pair.
Mutual Capacitance: Capacitance between
two conductors when all other conductors are
connected together to shield and ground.
Mylar®: DuPont trademark for polyester film.
Nanometer (nm): One billionth of a meter
(10 –9 meter).
standards or has been tested and found suitable Messenger: Supporting member, usually a high-
for use in a specified manner.
strength steel wire, used to suspend aerial
cable. The messenger may be an integral part of
the cable, or exterior to it (lashed messenger).
Microbending Loss: (fiber optic) Loss due to
small geometrical irregularities along the core-
clad interface of the fiber.
Local Area Network (LAN): A geographically
limited communications network intended for
the local transport of data, video and voice.
Longitudinal Shield: A tape shield, flat or
corrugated, applied longitudinally with the axis
of the core being shielded.
Microfarad: One-millionth of a farad, commonly
abbreviated m-F.
Longitudinal Wrap: Tape applied longitudinally
with the axis of the core being covered.
Loop Resistance: The total resistance of two
conductors measured round-trip from one end.
Commonly used term in the thermocouple
industry.
Looping-in: Wiring method which avoids tee
joints by carrying the conductor or cable to and
from the point to be supplied.
Loss: Energy dissipated without accomplishing
useful work.
Loss Factor: The product of the dissipation and
dielectric constant of an insulating material.
Lossy Line: A cable having large attenuation per
unit of length.
Low-Loss Dielectric: An insulating material
that has a relatively low dielectric loss, such as
polyethylene or Teflon®.
Micromicrofarad: One-millionth of a microfarad. Nanosecond: One billionth of a second
(uuf, uufd, mmf, mmfd m‑m F are common
abbreviations.)
(10 -9 seconds).
National Electric Code (NEC): A set of
regulations governing construction and
installation of electrical wiring and apparatus in
the United States, established by the American
National Board of Fire Underwriters.
Microwave: A short (usually less than 30 cm.)
electrical wave.
Mil: A unit used in measuring diameter of a wire
or thickness of insulation over a conductor. One-
one thousandth of an inch (.001").
Mineral-Insulated: Cable and thermocouple
wire consisting of one or more conductors
surrounded by magnesium oxide insulation
and enclosed in a liquid- and gas-tight metallic
sheathing.
Neoprene: A synthetic rubber with good
resistance to oil, chemical and flame. Also called
polychloroprene.
Noise: In a cable or circuit, any extraneous signal
which tends to interfere with the signal normally
present in or passing through the system.
Nomex®: DuPont trademark for a temperature-
resistant, flame-retardant nylon.
Non-Contaminating: Type of PVC jacket material
whose plasticizer will not migrate into the
dielectric of a coaxial cable and thus avoids
contaminating and destroying the dielectric.
Miniature Wire: Insulated conductors of
approximately 20-34 AWG.
Mis-Match: A termination having a different
impedance than that for which a circuit or cable
is designed.
Mode: One of the components of a general
configuration of a propagating wave front.
211
Electronics
Technical Information
Glossary
Nylon: Thermoplastic with good chemical and
abrasion resistance.
Parallel Stripe: A stripe applied longitudinally
on a wire or cable parallel to the axis of the
conductor.
Plug: The part of the two mating halves of a
connector which is moveable when not fastened
to the other mating half.
Ply: The number of individual strands or filaments
twisted together to form a single thread.
Point-to-Point: A type of connection established
between two specific locations, as between two
buildings.
Point-to-Point Wiring: An interconnecting
technique wherein the connections between
components are made by wires routed between
connecting points.
NVP: Nominal Velocity of Propagation.
Off Center: Conductor displaced within the cross- Patch Cord: A length of cable with
section of its insulation.
connectors on one or both ends used to join
Offgassing: Percentage of a specified gas
released during the combustion of insulation or
jacketing material.
telecommunications links/circuits at the cross-
connect.
Patch Cord Cable: Bulk cable used in the
manufacture of patch cords.
Ohm: A unit of electrical resistance.
Oil Aging: Cable aged in an accelerated manner
by placement in an oil bath and heated to a pre-
set temperature for a stated time.
Patch Panel: A cross-connect system of mateable
connectors that facilitates administration.
Pathway: A facility for the placement of
Oil-Filled Cable: A self-contained pressure cable
telecommunications cable. Synonym: Raceway. Polarization: The orientation of a flat cable or a
in which the pressure medium is low viscosity oil Pay-Off: The process of feeding a cable or wire
rectangular connector.
having access to the insulation.
Opaque: (fiber optic) Not permitting the passage
of light.
from a bobbin, reel or other package.
Percent Plating: Quantity of plating on a
conductor expressed as a percentage by
weight.
Percentage Conductivity: Conductivity of a
material expressed as a percentage of that of
copper.
Polishing: (fiber optic) Act of smoothing ends of
fibers to an ‘optically smooth’ finish, generally
using abrasive.
Open Cell: Foamed or cellular material with cells
which are generally interconnected.
Optical Communication Cable: (fiber optic) Fiber
with a protective jacket around it.
Polyester: Polyethylene terephthalate, used
extensively as a moisture-resistant cable core
wrap.
Polyethylene: A thermoplastic material having
excellent electrical properties.
Optical Conductors: (fiber optic) Materials which Periodicity: The uniformly spaced variations in
offer a low optical attenuation to transmission of
light energy.
the insulation diameter of a transmission cable
that result in reflections of a signal, when its
wavelength or a multiple thereof is equal to the
distance between two diameter variations.
Permittivity: See Dielectric Constant.
Polyhalocarbon: A general name for polymers
containing halogen atoms. The halogens are
fluorine, chlorine, bromine and iodine.
Polymer: A material of high molecular weight
formed by the chemical union of monomers.
Polyolefin: Any of the polymers and copolymers
of the ethylene family of hydrocarbons.
Polypropylene: A thermoplastic similar to
polyethylene but stiffer and having higher
softening point (temperature); excellent electrical
properties.
Optical Fiber Cable: An assembly consisting of
one or more optical fibers.
Optical Fiber Duplex Adapter: A mechanical
media termination device designed to align and Phase: An angular relationship between waves.
join two duplex connectors.
Phase Shift: A change in the phase relationship
between two alternating quantities.
Photodetector (Receiver): Converts light energy
to electrical energy.
Optical Fiber Duplex Connector: A mechanical
media termination device designed to transfer
optical power between two pairs of optical
fibers.
Pick: Distance between two adjacent crossover
points of braid filaments. The measurement in
picks per inch indicates the degree of coverage.
Picofarad: One-millionth of one-millionth of
a farad. A micromicrofarad or picofarad
(abbreviation pf). (See mm F).
Optical Waveguide: (fiber optic) A fiber used
for optical communications. Analogous
to a waveguide used for microwave
communications.
Oscillatory Surge: A surge which includes both
positive and negative polarity values.
Outgassing: The dissipation of gas from a
dielectric evidencing decomposition.
Outlet Box, Telecommunications: A metallic or
nonmetallic box mounted within a wall, floor or
ceiling and used to hold telecommunications
outlet/connectors or transition devices.
Polyurethane: Class of polymers known for good
abrasion and solvent resistance (may be applied
in solid or cellular form).
Porosity: Multiple voids in an insulation cross-
section.
Pigtail Wire: Fine-stranded, extra-flexible, rope-
lay lead wire attached to a shield for terminating
purposes.
Potting: The sealing of a cable termination or
other component with a liquid which thermosets
into an elastomer.
Pitch: In flat cable, the nominal distance between Power Cables: Cables of various sizes,
the index edges of two adjacent conductors.
Pitch Diameter: Diameter of a circle passing
through the center of the conductors in any layer
of a multiconductor cable.
construction and insulation, single or multi-
conductor designed to distribute primary power
to various types of equipment.
Outlet/Connector, Telecommunications:
A
Power Factor: The ratio of resistance to
impedance. The ratio of the actual power
of an alternating current to apparent power.
Mathematically, the cosine of the angle between
the voltage applied and the current resulting.
Pre-Bond: Stranded wire which has been fused,
topcoat-tinned or overcoat-tinned.
connecting device in the work area on which
horizontal cable terminates.
Plain Conductor: A conductor consisting of only
one metal.
Overall Diameter: Finished diameter over wire or Plain Weave: A weave used on woven cables.
cable.
Threads between the wires act as binders
and give the cable lateral stiffness and linear
flexibility. Also called Standard and Square
Weave.
Planetary Cabler: A cabler capable of laying
down any number of shielded, overbraided or
jacketed singles, pairs, called groups, or any
combination of them in sequence.
Planetary Twister: A twisting machine whose
payoff spools are mounted in rotating cradles
that hold the axis of the spool in a fixed direction
as the spools are revolved so no twist is built up
in each wire.
Plastic Deformation: Change in dimensions
under load that is not recovered when the load
is removed.
Overcoat Conductor: A stranded conductor
made from individual strands of tin-coated wire
stranded together, and then given an overall tin
coat.
Overlap: The amount the trailing edge laps over
the leading edge of a spiral tape wrap.
Oxygen Index: Percentage of oxygen necessary
to support combustion in a gas mixture.
Ozone: Reactive form of oxygen, typically found
around electrical discharges and present in the
atmosphere in small quantities.
Prewiring: Wiring installed
•
Before walls are enclosed or finished.
•
In anticipation of future use or need.
Primary: The transformer winding which receives
the energy from a supply circuit.
Primary Insulation: The first layer of non-
conductive material applied over a conductor,
whose prime function is to act as electrical
insulation.
Primary Protection: The minimum protection
required on all exposed facilities to comply with
NEC requirements.
Primary Wiring: A printed circuit intended to
provide point-to-point electrical connections.
Programming: Ability to select various circuit
patterns by interconnecting appropriate
contacts on one side of a connector plug or
panel.
Packing Fraction: (fiber optic) The ratio of active
cross-sectional area of fiber core, or cores, to
the total end surface of the fiber, or fiber bundle.
Pair: Two insulated wires of a single circuit
associated together, also known as a “balance” Plasticizer: A chemical agent added to plastics to
transmission line.
make them softer and more pliable.
Plenum: The air return path of a central air
handling system, either ductwork or open space
over a suspended ceiling.
Plenum Cable: Cable approved by a recognized Propagation Delay: Time delay between input
agency such as UL for installation in plenums
without the need for conduit.
Parallel Pair: A duplex construction of two
insulated conductors laid parallel and then
covered overall with a braid or jacket.
and output of signal.
212
Technical Information
Electronics
Glossary
Propagation Time: Time required for a wave to
travel between two points on a transmission line.
Protocol: A set of rules for communicating.
Proximity Effect: Nonuniform current distribution
over the cross-section of a conductor caused
by the variation of the current in a neighboring
conductor.
Reinforced Sheath: The outermost covering of
a cable that has cable sheath constructed in
layers with the addition of a reinforcing material,
usually a braided fiber, molded in place between
layers.
Segmental Conductor: A stranded conductor
consisting of three or more stranded conducting
elements, each element having approximately
the shape of the sector of a circle, assembled to
give a substantially circular cross-section.
Remanence: The magnetic induction that remains Selenium Cure: Process used to cure neoprene
in a magnetic circuit after the removal of an
applied magnetomotive force.
Repeater: A device which consists of a
transmitter and a receiver or transmitter, used
to regenerate a signal to increase the system
transmission length.
and rubber jacketed wires and cables.
Self-Extinguishing: Characteristic of a material
whose flame is extinguished after the igniting
flame source is removed.
Semi-Conducting Jacket: A jacket having a
sufficiently low resistance so that its outer
surface can be kept at substantially ground
potential.
Semi-Rigid: A cable containing a flexible inner
core and a relatively inflexible sheathing.
Semi-Solid: An insulation cross-section having a
partially open space between the conductor and
the insulation perimeter.
Pull Box: A device to access a raceway used to
facilitate placing of wire or cables.
Pull Cord/Pull Wire: Cord or wire placed within a
raceway and used to pull wire and cable through
the raceway.
Pull Strength: See Pull Tension.
Resistance: A measure of the difficulty in moving
electrical current through a medium when
voltage is applied. It is measured in Ω.
Resistive Conductor: A conductor with high
electric resistance.
Pull Tension: The maximum pulling force that can
be safely applied to a cable without damage.
Pulling Eye: A device used to pull cable into or
from a duct.
Pulse: Energy which changes abruptly from an
intensity to another. May be light energy or
electrical energy.
Retractile Cord: A cord having specially treated
insulation or jacket so that it will retract.
Return Wire: A ground wire or the negative wire in Separator: A layer of insulating material which is
Pulse Cable: A type of coaxial cable constructed
a direct-current circuit.
placed between a conductor and its dielectric
between a cable jacket and the components it
covers, or between various components of a
multiple-conductor cable.
Series Circuit: A circuit in which the components
are arranged end to end to form a single path
for current.
to transmit repeated high-voltage pulses without Ribbon Cable: A flat cable of individually insulated
degradation.
conductors lying parallel and held together by
means of adhesive or woven textile yarn.
Ridge Marker: One or more ridges running
laterally along the outer surface of a plastic-
insulated wire for purposes of identification.
Polyvinyl Chloride (PVC): A general-purpose
thermoplastic widely used for wire and cable
insulations and jackets.
Quad: A series of four separately insulated
conductors, generally twisted together in pairs. Rigid Bay: Cabling equipment that maintains
Serve: A filament or group of filaments such as
fibers or wires, wound around a central core.
Serving: A wrapping applied over the core of a
cable or over a wire.
Also, a series-parallel combination of transistors
with increased reliability because failure of one
transistor will not disable the entire circuit.
Quadders: Three-bay machines which can twist
four wires together and cable braided and
shielded wires with varying lay lengths.
Raceway: Any channel designed for holding
wires or cables, e.g. conduit, electrical metallic
tubing, sleeves, slots, underfloor raceways,
cellular floors, surface raceways, lighting
fixture raceways, wireways, cable troughs,
busways, auxiliary gutters and ventilated flexible
cableways. Synonym: Pathway.
component sequence, and can produce cables
with distinct layers.
Rigid Coaxial Cable: Nonflexible coaxial cable,
usually a metal tube armored coaxial cable.
Sheath: See Cable Sheath.
Ring Tongue: A solderless terminal that connects Shield: In cables, a metallic layer placed around
wire to a stud.
a conductor or group of conductors to prevent
electrostatic or electromagnetic interference
between the enclosed wires or external fields.
Shield Coverage: Amount of outer cable covered
by the shielding material.
Ringing Out: Locating or identifying specific
conductive paths by passing current through
selected conductors.
Rip-Cord: 1.) Two or more insulated conductors in
a parallel configuration which may be separated Shield Effectiveness: The ability of a shield to
to leave the insulation of each conductor intact.
screen out undesirable signals.
2.) A small filament cord used to rip through the Shielded Line: A transmission line whose
Rack: See: Cable Rack.
outer cable sheath.
elements confine propagated radio waves
to an essentially finite space inside a tabular
conducting surface called the sheath, thus
preventing the line from radiating radio waves.
Shielded-Type Cable: A cable in which the
surface of the insulation is at ground potential.
Radio Frequency: The frequencies in the
electromagnetic spectrum that are used for
radio communications.
RoHS (Restriction on Hazardous Substances):
European Union directive that restricts use of
heavy metal substances.
Random Winding: A winding in rotating
equipment wherein the wires do not lie in an
even pattern.
Rope Concentric: A group of standard
conductors assembled in a concentric manner.
Rope Lay Conductor: A conductor composed of Shunt Wire: A conductor joining two parts of an
Reactance: The opposition offered to the flow of
alternating current by inductance or capacitance
of a compound or circuit.
a central core surrounded by one or more layers
of helically laid groups of wires.
electric circuit to divert part of the current.
Signal: A current used to convey information,
either digital, analog, audio or video.
Silicone: A material made from silicon and
oxygen. Can be in thermosetting elastomer or
liquid form. The thermosetting elastomer form is
noted for high heat resistance.
Rope Unilay: A group of stranded conductors
assembled in a unilay manner.
Red Plaque: A powdery, brown-red growth found
on silvercoated copper conductors and shield
braids.
Round Wire Shields: Shields constructed from
bare, tinned or silver-plated copper wire that
include braided, spiral and reverse spiral.
Redraw: The consecutive drawing of wire through
a series of dies to reach a desired wire size.
Reducing Joint: A joint between two lengths of
cable where the conductors are not the same
size.
Routers: A device that determines how to forward Silicone Treating: A silicone liquid treatment
a packet toward its destination, based on tables
that indicate the costs, congestion status and
other factors associated with possible routes.
Also called a level 3 relay or an intermediate
system.
applied to insulated conductors to allow for easy
jacket stripping.
Sine Wave: A wave that can be expressed as
the sine of a linear function of time, or space or
both.
Reel: A revolvable flanged device made of wood
or metal, used for winding flexible metal wire or
cable.
Rubber (Wire Insulation): Term used to describe Single-ended: Unbalanced, such as grounding
Reflection: (fiber optic) Change in direction of a
light wave or ray.
wire insulations made of thermosetting
elastomers; occurs naturally or may be made
synthetically.
one side of a circuit or transmission line.
Single-Faced Tape: Fabric tape finished on one
side with a rubber or synthetic compound.
Singlemode Fiber: A fiber wave guide in which
only one mode will propagate. The fiber has a
very small core diameter of approximately 8mm.
It permits signal transmission at extremely high
bandwidths and is generally used with laser
diodes.
Reflection Loss: The part of a signal which is lost
due to reflection of power at a line discontinuity. Rulan®: DuPont’s trade name for their flame-
Refraction: (fiber optic) The bending of lightwaves
retardant polyethylene insulating material.
or rays as they go from one material to another Screen: A shield placed over the entire core.
due to the difference in velocities in the
materials.
Secondary Insulation: A nonconductive material
that protects the conductor against abrasion
and provides a second electrical barrier.
213
Electronics
Technical Information
Glossary
Sizing: Applying a material to a surface to fill
pores.
Standing Wave Ratio (SWR): In a transmission
line, waveguide, or analogous system, a figure
of merit used to express the efficiency of the
system in transmitting power.
Telecommunications: The communication of
information over some distance, including
interbuilding and intrabuilding distances.
Telecommunications Closet: See Closet,
Telecommunications.
Skeleton Braid: Widely separated braid of fiber
copper or steel, used to hold core together, for
reinforcing jacket or for shielding.
Star Topology: A topology in which each
Skew Rays: A ray that does not intersect the fiber
axis. Generally, a light ray that enters the fiber
core at a very high angle.
telecommunications outlet/connector is directly Telecommunications Entrance Facility: See
cabled to the distribution device.
Stay Cord: A component of a cable used
to anchor the cable ends at their points
of termination and to keep any pull of the
cable from being transferred to the electrical
connections.
Entrance Facility, Telecommunications.
Telecommunications Entrance Point: See
Entrance Point, Telecommunications.
Telecommunications Entrance Room or
Space: See Entrance Room or Space,
Telecommunications.
Telecommunications Equipment Room: See
Equipment Room, Telecommunications.
Telecommunications Grounding Busbar:
A common point of connection for
telecommunications system and bonding
to ground, which is located in the
telecommunications closet or equipment room.
Telecommunications Infrastructure: See
Infrastructure, Telecommunications.
Skim Tape: Filled tape coated on one or both
sides with a thin film of uncured rubber or
synthetic compound to produce a coating
suitable for vulcanization.
Skin Effect: The tendency of alternating current,
as its frequency increases, to travel only on the
surface of a conductor.
Step Index Fiber: (fiber optic) A multimode
fiber consisting of a core of uniform refractive
index surrounded by cladding of slightly lower
refractive index.
Sleeve: A braided, knitted or woven tube used
over wires or components as insulation tubing.
Also called Sleeving.
Strand: One of the wires of any stranded
conductor.
Solid Conductor: A conductor consisting of a
single wire.
Strand Lay: The distance of advance of one
strand of a spirally stranded conductor, in one
turn, measured axially.
Source Coupling Loss: (fiber optic) Loss of light
intensity as light from source passes into fiber.
Space, Telecommunications: An area used
for housing the installation and termination of
telecommunications equipment and cable, e.g.
telecommunications closets, work areas and
manhole/handholes.
Stranded Conductor: A conductor composed of Telecommunications Outlet/Connector: See
groups of wires twisted together.
Outlet/Connector, Telecommunications.
Telemetry Cable: Cable used for transmission of
information from instruments to the peripheral
recording equipment.
Temperature Rating: The maximum temperature
at which an insulating material may be used in
continuous operation without loss of its basic
properties.
Strap: Square- or rectangular-section bare
conductor manufactured and used in coil form.
Strip: To remove insulation from a cable.
Structural Return Loss: Backward reflected
energies from uneven parts of the cable
structure causing impedance variations are
termed structural return loss.
Span: (1.) In flat conductors, distance between
the reference edge of the first and the last
conductor. (2.) In round conductors, distance
between centers of the first and last conductors. Surface Resistivity: The resistance of a material Tensile Strength: The pull stress required to
(3.) In aerial cable, the distance between poles
or support clamps.
between two opposite sides of a unit square of
its surface. It is usually expressed in Ω.
break a given specimen.
Tension Member: A member included in a fiber
cable to add tensile strength.
Terminal: (1) A point at which information may
enter or leave a communications network;
(2) the input-output associated equipment; or
(3) a device by means of which wires may be
connected to each other.
Spark Test: A test designed to locate pin-holes in Surge: A temporary and relatively large increase
the insulation of a wire or cable by application of
a voltage for a very short period of time while the
in the voltage or current in an electric circuit or
cable. Also called Transient.
wire is being drawn through the electrode field. Suspended Ceiling: See False Ceiling.
Specific Gravity: The ratio of the density (mass
per unit volume) of a material to that of water.
Spectral Bandwidth: The difference between
wavelengths at which the radiant intensity of
illumination is half its peak intensity.
Spectral Response: (fiber optic) The response
of a detector (or a system) over different
wavelengths.
Sweep-test: Pertaining to cable, the frequency
response is verified by generating an rf voltage
whose frequency is swept repeatedly through a Termination Hardware: This term is outmoded.
given frequency range at a rapid constant rate
while the cable response is observed.
Take-Up: The process of accumulating wire or
cable onto a reel, bobbin or some other type of
pack. Also, the device for pulling wire or cable
through a piece of equipment or machine.
Tank Test: A voltage dielectric test in which the
test sample is submerged in water and voltage
is applied between the conductor and water as
ground.
See Connecting Hardware.
Test Lead: A flexible, insulated lead wire used for
making tests, connecting instruments to a circuit
temporarily or for making temporary electrical
connections.
Spectrum: Frequencies that exist in a continuous
range and have a common characteristic.
Speed of Light (c): 2.998 x 108 meters per
second.
Textile Braid: Any braid made from threads of
cotton silk, or synthetic fibers.
Thermal Aging: Exposure to a thermal condition
or programmed series of conditions for
predescribed periods of time.
Thermocouple Lead Wire: An insulated pair of
wires used from the couple to a junction box.
Thermoplastic: A material which softens when
heated and becomes firm on cooling.
Thermoset: A material which hardens or
sets when heat is applied, and which, once
set, cannot be resoftened by heating. The
application of heat is called “curing.”
Three-Phase Current: Current delivered through
three wires, with each wire serving as a return
for the other two.
Spiral Shield: A metallic shield of fine-stranded
wires applied spirally rather than braided.
Spiral Stripe: A color-coding stripe applied
helically to the surface of an insulated wire or
cable.
Tape: A relatively narrow woven or cut strip of
fabric, paper or film material.
Tape Cable: A form of multiple conductor
consisting of parallel metal strips imbedded in
insulating material.
Spiral Wrap: The helical wrap of a tape or thread
over a core.
Tape Wrap: A spirally applied tape over an
insulated or uninsulated wire.
Splice: A joining of conductors, generally from
separate sheaths.
Taped Insulation: Insulation of helically wound
tapes applied over a conductor or over an
assembled group of insulated conductors.
Taping: Process of insulating continuous length,
Splice Closure: A device used to protect a cable
or wire splice.
Spread Spectrum: A modulation technique for
multiple access, or for increasing immunity to
noise and interference.
large diameter wires with tape of non-extrudable Three-Phase Three-Wire System: An alternating
materials.
current supply system comprising three
conductors over which three-phase power is
sent.
Three-Wire System: A d-c or single-phase a-
c system comprising three conductors, one
of which is maintained at a potential midway
between the potential of the other two.
Tin Overcoat (TOC): Tinned copper wire,
stranded, then coated with pure tin.
Standing Wave: The stationary pattern of waves TB: Terminal Block
produced by two waves of the same frequency Tear Strength: The force required to initiate or
traveling in opposite directions on the same
transmission line.
continue a tear in a material under specified
conditions.
Teflon®: DuPont company trade name for
fluorocarbon resins. FEP, PFA and TFE are
typical materials.
Tefzel®: DuPont trade name for a fluorocarbon
material typically used as a wire wrap insulation.
214
Technical Information
Electronics
Glossary
Tinsel Wire: A low-voltage stranded wire, with
each strand a very thin conductor ribbon spirally
wrapped around a textile yarn.
Twin Cable: A pair of insulated conductors
Watt: A unit of electric power.
twisted, sheathed or held together mechanically Wave Form: A graphical representation of a
and not identifiable from each other in a
common covering.
varying quantity. Usually, time is represented on
the horizontal axis, and the current or voltage
value is represented on the vertical axis.
Topcoat: Bare (untinned) copper wire, stranded
then coated with pure tin.
Twin Coaxial: A configuration containing two
Topology: The physical or logical arrangement of
a telecommunications system.
Tracer: A means of identifying polarity.
Transducer: A device for converting mechanical
energy to electrical energy.
separate, complete coaxial cables laid parallel or Wave Length: The distance, measured in the
twisted around each other in one complex.
Twin Line: A transmission line which has a solid
insulating material, in which the two conductors
are placed in parallel to each other.
direction of propagation, of a repetitive electrical
pulse or waveform between two successive
points that are characterized by the same phase
of vibration.
Wicking: The longitudinal flow of a liquid in a wire
or cable due to capillary action.
Wire: A conductor, either bare or insulated.
Transfer Impedance: The ratio of the source
voltage of the wires inside the cable to the shield
current of the cable or connectorized cable
assembly.
Twinner: A device for twisting together two
conductors.
Twisted Pairs: A cable composed of two small
insulated conductors twisted together without a Wire and Cable Marker: Device for identification
Transition Point: A location in the horizontal
cabling where flat undercarpet cable connects
to round cable.
common covering.
marking of wire and cable.
Unbalanced Line: A transmission line in which
voltages on the two conductors are unequal
with respect to ground.
Wire and Cable Tying, Clamping, and
Harnessing Devices: Tying tapes, lacing cords
and flexible sleevings which are used for wire
and cable bundling, harnessing and holding.
Other devices include plastic ties or clamps,
spiral-cut plastic tubing and plastic U-shaped
trays or ducts.
Transmission: Transfer of electric energy from
one location to another through conductors or
by radiation or induction fields.
Unidirectional Concentric Stranding:
A
stranding where each successive layer has a
different lay length, thereby retaining a circular
form without migration of strands from one layer
to another.
Transmission Cable: Two or more transmission
lines. See Transmission Line.
Transmission Line: An arrangement of two
or more conductors or a wave guide used to
transfer signal energy from one location to
another.
Wire and Lead Cutters: Tools for cutting that
range from plier-type cutters to semiautomatic
or fully automatic machines integrated with other
wire processing operations such as stripping,
forming and terminating.
Unidirectional Stranding: A term denoting that in
a stranded conductor, all layers have the same
direction of lay.
Transmission Loss: The decrease or loss in
power during transmission of energy from one
point to another. Usually expressed in decibels.
Transmission Media: The various types of wire
and optical fiber cable used for transmitting
voice or data signals. Typically, wire cable
includes twisted pair, coaxial and twinaxial.
Optical fiber cable includes single, dual, quad,
stranded and ribbon (Al).
Transmitter: The electronic package that injects
an electrical signal or light signal over the
transmission medium.
Transparent: (fiber optic) Transmitting rays of
light so that objects can be seen through the
material.
Transposition: Interchanging the relative positions
of wires to neutralize the effects of induction to
or from other circuits or, to minimize interference
pickup by the lead-in during reception.
Tray Cable: A factory-assembled multiconductor
or multipair control cable approved under the
National Electrical Code for installation in trays.
Triaxial: A three-conductor cable with one
conductor in the center, a second circular
conductor shield concentric with the first, and
third circular conductor shield insulated from
and concentric with the first and second, usually
with insulation, and over a braid or impervious
sheath overall.
Unilay Strand: A conductor constructed with a
central core surrounded by more than one layer Wire Gauge: A system of numerical designation
of helically-laid wires, with all layers having a
common length and direction of lay.
of wire sizes.
Wire Nut: A closed-end splice that is screwed on
instead of crimped.
Wire Wrapped Connection: A solderless
connection made by wrapping bare wire around
a square or rectangular terminal with a power or
hand tool.
Wire Wrapping Tools: Portable electric tools and
automatic stationary machines used to make
solderless wrapped connections of wires to
terminals.
Velocity of Propagation (VP): The speed of
an electrical signal down a length of cable
compared to speed in free space expressed as
a percent. It is the reciprocal of the square root
of the dielectric constant of the cable insulation.
Volt: A unit of electromotive force.
Voltage: The term most often used in place of
electromotive force, potential difference or
voltage drop to designate the electric pressure
that exists between two points and is capable
of producing a current when a closed circuit is
connected between two points.
Voltage Drop: The voltage developed across a
component or conductor by the current in the
resistance or impedance of the component or
conductor.
Voltage Rating: The highest voltage that may be
continuously applied to a wire in conformance
with standards or specifications.
Wiring Closet: See Telecommunications Closet.
Work Area (Work Station): A building
space where the occupants interact with
telecommunications terminal equipment.
Wrapper: An insulating barrier applied as a sheet
or tape wrapped around a coil periphery.
Yield Strength: The minimum stress at which a
material will start to physically deform without
increase in load.
Zytel®: DuPont’s trade name for nylon resins.
Voltage Standing Wave Ratio (VSWR): The
ratio of the maximum effective voltage to the
minimum effective voltage measured along
the length of a mis-matched radio frequency
transmission line.
Sections of this glossary are reprinted with permission
from December, 1985 Issue of ELECTRONICS copyright
1985. Lake Publishing Corporation, 17730 W. Peterson
Rd., Libertyville, IL 60048-0159 USA. Permission to reprint
granted to the General Cable Corporation.
No additional reproduction of this wire and cable glossary
allowed without written permission.
Volume Resistivity (Specific Insulation
Resistance): The electrical resistance between
opposite faces of a 1 cm. cube of insulating
material, commonly expressed in Ω/centimeter.
Vulcanization: A chemical reaction in which the
physical properties of an elastomer are changed
by reacting it with sulfur or other cross-linking
agents.
Triboelectric Noise: Noise generated in a
shielded cable due to variations in capacitance
between shielding and conductor as the cable
is flexed.
Triple Cable: A cable composed of three insulated
single conductors and one bare conductor,
all twisted together. It may or may not have a
common covering of binding.
Wall Thickness: The thickness of the applied
insulation or jacket.
True Concentric: A cable in which each
successive layer has a reversed direction of lay Water Absorption: A test to determine the water
from the preceding layer.
absorbed by a material after a given immersion
period.
Trunk Cable: See Feeder Cable.
Tubing: A tube of extruded non-supported plastic Waterblocked Cable: A cable constructed with
material.
no internal voids in order to allow no longitudinal
water passage under a given pressure.
215
Electronics
Technical Information
Abbreviations & Acronyms
A-D: Analog to digital conversion
ac: Alternating current
AC: Armored Cable, NEC Article 333 Cable
Designation
CEN: European Committee for Standardization
E: Symbol for voltage. Usually used to represent
direct voltage or the effective (root-mean-square)
value of an alternating voltage
EFTS: Electronic funds transfer system
EIA: Electronic Industries Association
EMF: Electromotive Force
EMI: Electromagnetic Interference
EMT: Electric Metallic Tubing
EP: Entrance point
EPDM: Ethylene-propylene-diene monomer rubber
EPOS: Electronic Point-Of-Sale
EPR: Ethylene-propylene rubber
ER: Equipment room
ESS: Electronic Switching System
ESTA: Australian approval agency; Electricity Trust
of South Australia
CENELEC: European Committee for
Electrotechnical Standardization
CFC: Communications Flat Cable
ckt: Circuit
CLT or CLOS: Closet
CL2: Class 2 Circuit Cable, NEC Article 725 Cable
Designation
CL2P: Class 2 Circuit Plenum Cable, NEC Article
725 Cable Designation
CL2R: Class 2 Circuit Riser Cable, NEC Article 725
Cable Designation
CL2X: Class 2 Circuit Limited Use Cable, NEC
Article 725 Cable Designation
CL3: Class 3 Circuit Cable, NEC Article 725 Cable
Designation
CL3P: Class 3 Circuit Plenum Cable, NEC Article
725 Cable Designation
CL3R: Class 3 Circuit Riser Cable, NEC Article 725
Cable Designation
CL3X: Class 3 Circuit Limited Use Cable, NEC
Article 725 Cable Designation
CM: Communications Cable, NEC Article 800 Cable
Designation
CMA: Circular Mil Area
CMP: Communication Cable Plenum, NEC Article
800 Cable Designation
CMR: Communications Cable Riser, NEC Article
800 Cable Designation
CMX: Communications Limited Use Cable, NEC
Article 800 Cable Designation
CO: Central Office
AC0: Analog Central Office
ACR: Attenuation to Crosstalk Ratio
ADO: Auxiliary Disconnect Outlet
AER: Aerial
AF: Audio frequency
AIA: American Institute of Architects
ALPETH: An aerial telephone cable having an alu-
minum shield and polyethylene jacket
ALS: A type of cable consisting of insulated con-
ductors enclosed in a continuous, closely fitting
aluminum tube
ALVYN: An indoor, riser rated telephone cable hav-
ing an aluminum shield and vinyl jacket (PVC)
AM: Amplitude Modulation
ANSI: American National Standards Institute
ARPANET: Advanced Research Projects Agency
Network
ASCII: American Standard Code for Information
Interchange
ASME: American Society of Mechanical Engineers
ASP: A filled, direct burial telephone cable used in
areas subject to rodent attack. It consists of a
filled cable core, corrugated aluminum shield,
corrugated steel tape, flooding compound and
polyethylene jacket.
ASTA: United Kingdom approval agency
ASTM: American Society for Testing and Materials
AWG: American Wire Gauge
AWM: Appliance wiring material
B & S Gauge: See American Wire Gauge (AWG)
B or BUR: Buried
AWM: Appliance wiring material
BCF: Billion Conductor Feet
BEF: Building Entrance Facility
BER: Bit Error Rate
BIC: Building Industry Consultant
BICSI: Building Industry Consulting Service
International
BISDN: Broadband Integrated Services Digital
Network
BTU: British Thermal Unit
CA: Cable
CATV: (1) Community Antenna Television; Cable
Access Television (2) CATV Cable, NEC Article
820 Cable Designation
CATVP: CATV Plenum Cable, NEC Article 820 Cable
Designation
CATVR: CATV Riser Cable, NEC Article 820 Cable
Designation
CATVX: CATV Limited Use Cable, NEC Article 820
Cable Designation
ETPC: Electrolytic Tough Pitch Copper
ETV: Educational Television
E/W: Equipped With
EX or EXT: Extension
EXCH: Exchange
f: Frequency
FAA: Federal Aeronautics Administration
FCC: (1) Federal Communications Commission (2)
Flat Conductor Cable, NEC Article 328 Cable
Designation
FDDI: Fiber Distributed Data Interface
FDM: Frequency-Division Multiplexing
FDR: Feeder
FEP: Fluorinated ethylene propylene
FEXT: Far End Crosstalk
FI: Approval agency of Finland; Electrical
Inspectorate
FIPS PUB: Federal Information Processing
Standard Publication
FM: Frequency modulation
FOCIS: Fiber Optic Connector Intermateability
Standard
FOTP: Fiber Optic Test Procedure
FOTS: Fiber Optics Transmission System
FPL: Power Limited Fire Protective Signaling Circuit
Cable, NEC Article 760 Cable Designation
FPLP: Power Limited Fire Protective Signaling
Circuit Plenum Cable, NEC Article 760 Cable
Designation
FPLR: Power Limited Fire Protective Signaling
Circuit Riser Cable, NEC Article 760 Cable
Designation
FR-1: A flammability rating established by
Underwriter's Laboratories for wires and cables
that pass a specially designed vertical flame test
freq: Frequency
FRICC: Federal Research Internet Coordinating
Committee (now FNC)
FRPE: Flame Retardant Polyethylene
ft: Foot
FTP: Fire Transfer Protocol
ga: Gauge
gHZ: Gigahertz
grd: Ground
codec: Coder decoder
COE: Central Office Equipment
COS: Cooperation for Open Systems
COSINE: Cooperation for Open Systems
Interconnection Network in Europe
COT: Central Office Terminal
CPC: Customer Premises Communication
CPE: (1) Chlorinated Polyethylene (2) Customer
Premises Equipment or Customer Provided
Equipment
CPU: Central Processing Unit
CRT: Cathode Ray Tube
CSMA/CD: Carrier Sense Multiple Access/
Collision Detection
CSPE: Chlorosulfonated Polyethylene
CTR: Certified Test Report
CV: Continuous vulcanization
D-A: Digital to analog conversion
DAF: Dedicated Access Facility
dB: Decibel
DBS: Direct Broadcast Satellite
dc: Direct current
DCE: Data Circuit-Terminating Equipment
DCO: Digital Central Office
DCR: Direct Current Resistance
DD: Distribution Designer or Distribution Device
DEMARC: Demarcation point
DEMKO: Approval agency of Denmark
DGM: Data Grade Medium
CB: Citizens band
C-C: Conductor to conductor capacitance
CCITT: The International Telegraph and Telephone
Consultative Committee
CCTV: Closed-circuit television
CDDI: Copper Distributed Data Interface
CDF: Central Distribution Frame
CDO: Community Dial Office
CEBEC: Belgium approval agency; Commite
Electrotechnique Belge Service de la Marque
CEE: European standards agency; International
Commission on Rules for the Approval of
Electrical Equipment
GTO: Gas tube sign and oil-burner ignition cable.
5,000V-15,000V.
DISA: Defense Information Systems Agency
(formerly DCA)
H: Designation for intensity of magnetic energy
hc: Handset combination (single-line telephone)
HC: Horizontal cross-connect
hck: Handset combination; key (six-button
telephone)
HDPE: High Density Polyethylene
HF: High Frequency
DISI: Directory Information Services Infrastructure
DIST: District
DRT: Plastic range and dryer cord (CSA)
DTE: Data Terminal Equipment
DVD: Digital Versatile Disc
DW: Distribution Wire
216
Technical Information
Electronics
Abbreviations & Acronyms
hh: Handhole
MDPE: Medium Density Polyethylene
PABX: Private Automatic Branch Exchange
Hi-Pot: A test designed to determine the highest
voltage that can be applied to a conductor
without breaking through the insulation.
HPD: Rubber- and asbestos-insulated heater cord.
No braid on individual conductors but with braid
overall. Also made with neoprene insulation and
no asbestos or PVC/NBC.
HPN: Two-conductor, neoprene-insulated heater
cord. Parallel construction. For use in damp
locations.
HSJ: Same as type HS but with #18, #16 and #14
conductors and differing thickness of jacket.
HVAC: Heating, ventilation and air conditioning
Hz: Hertz
i: Symbol used to designate current
IC: Intermediate cross-connect
ICEA: Insulated Cable Engineers Association
IDC: Insulation Displacement Connector
IEC: Internation Electrotechnical Commission
IEEE: Institute of Electrical and Electronics
Engineers
Meg or Mega: A numerical prefix denoting
PAM: Pulse Amplitude Modulation
PAP: A commonly used term for air core (unfilled)
direct burial telephone cable with a corrugated
aluminum shield
PBX: Private Branch Exchange
PC: Personal Computer
1,000,000 (106)
M/G: Motor/Generator Set
MH: Manhole
Mho: The unit of conductivity. The reciprocal of an
ohm.
MHz: Megahertz
MI: Mineral Insulated Cable, NEC Article 330
Cable Designation
Micro: A numerical prefix denoting one-millionth
(106)
MIL STD: Military Standard
MILNET: Military Network
MLT: Multi-Level Threshold
mm: Millimeter
Modem: Modulator demodulator
MTT: Main Telephone Terminal
MTW: Machine Tool Wire
MV: Medium Voltage Cable, NEC Article 326
Cable Designation
MW: Radio hookup wire with polyvinyl insulation
and plain or nylon jacket or braid, or shield,
1000V
PCB: Printed Circuit Board
P-FEP: General Cable proprietary dielectric
material used injunction with FEP.
PCM: Pulse Code Modulation
PCP: A commonly used term for air core (unfilled)
direct burial cable with a corrugated copper
shield
PE: Polyethylene
pf: Picofarad
PFA: Polyfluoroalkoxy
PIC: A general term for any type of plastic
insulated telephone cable
Pico: A numerical prefix denoting one-millionth of
one-millionth (10-12
)
PL: Private Lines
IGS: Integrated Gas Spacer Cable, NEC Article
325 Cable Designation
PLSJ: All-rubber, parallel-jacketed, two-
conductor, light-duty cord for pendant or
portable use in damp locations. 300V.
PLT: (1) Plant (2) Same as PLSJ except thermo-
plastic insulation
PLTC: Power Limited Tray Cable, NEC Article 725
Cable Designation
IMSA: International Municipal Signal Association
in: Inch
IRSG: Internet Research Steering Group
IRTF: Internet Research Task Force
IS: International Standard
ISA: Instrument Society of America
ISDN: Integrated Services Digital Network
ISO: International Organization for Standardization
ISOC: Internet Society
ITCO: Independent Telephone Company
ITU-T: International Telecommunications Union -
Telecommunications Standardization Section
IW (C): Inside Wiring (cable)
N: Newton
NAIC: Network Applications and Information
Center
NASA: National Aeronautics and Space
Administration
NBR: Natural butadiene-acrylonitrile copolymer
rubber
PM: Phase Modulation
POI: Point Of Interface
POSJ: All-rubber, parallel, light duty rip-cord for
use on lamps and small appliances, 300V, 60°C
POT: Thermoplastic, parallel, light duty rip-cord.
300V, 60°C to 105°C.
POTS: Plain Old Telephone Service (colloquial)
PP: Polypropylene
NBS: National Bureau of Standards (now NIST)
NEC: National Electrical Code
NEMA: National Electrical Manufacturers
Association
NEMKO: Approval agency of Norway
NESC: National Electrical Safety Code
NEXT: Near End Crosstalk
nf: Nanofarad
NFPA: National Fire Protection Association
NI: Network Interface
NID: Network Interface Device
NIST: National Institute of Standards and
Technology (formerly NBS)
NIU: Network Interface Unit
nm: Nanometer
NM & NMC: Non Metallic Sheathed Cable, NEC
Article 336 Cable Designation
NPLF: Non Power-Limited Fire Protective
Signaling Circuit Cable, NEC Article 760 Cable
Designation
NPLFP: Non Power-Limited Fire Protective
Signaling Circuit Plenum Cable, NEC Article 760
Cable Designation
NPLFR: Non Power-Limited Fire Protective
Signaling Circuit Plenum Cable, NEC Article 760
Cable Designation
NRZ: Non Return to Zero
NRZI: Non Return to Zero Inverted
OC: Optical Carrier
ODC: Ozone Depleting Chemical
OP: Outside Plant
OPE: Outside Plant Engineer
OSHA: Occupational Safety and Health
Administration
OSI: Open Systems Interconnection
OVE: Approval agency of West Germany;
Oesterreichischer Verband fur Elektrotechnik
PR: Pair
J: Joule
PTFE: Polytetrafluoroethylene
PTSS: Passive Transmission Sub-System
PVC: Polyvinyl Chloride
PVDF: Polyvinylidene Fluoride
R: Symbol for resistance
R-F: Radio-frequency
RCDD: Registered Communication Distribution
Designer
REA: Rural Electrification Administration
REP: Repair
RFQ: Request for Quote
RG/U: General utility grade military coaxial cable
RH: Relative humidity
RJ-45: A specific pin-point assignment for an eight
position modular telecommunications
connector.
kcmil: One thousand circular mils
KEMA KEUR: Approval agency of the Netherlands
kft: An abbreviation for 1000 ft.
kHz: Kilohertz
Kilo: A numerical prefix denoting 1000 (103)
km: Kilometer
KTS: Key Telephone Service
kV: Kilovolt
kVA: Kilovolt Ampere
kW: Kilowatt
LAN: Local Area Network
LASER: Light Amplification by Stimulated
Emission of Radiation
LATA: Local Access Transport Area
lbf: Pound force
LBO: Line Buildout
LDPE: Low Density Polyethylene
LEC: Local Exchange Carrier
LED: Light-Emitting Diode
LLDPE: Linear Low Density Polyethylene
LOCA: Loss of Coolant Accident
locap: Low-capacitance, low-loss paired cable
MAC: Moves, Adds and Changes
MAP: Manufacturing Automation Protocol
MATV: Master Antenna Television
Mbps: Megabits per second
MC: (1) main cross-connect (2) Metal Clad Cable,
NEC Article 334 Cable Designation
MCM: One thousand circular mils
MDF: Main Distribution Frame
RMS: (1) rack mount space (2) Root Mean
Squares
RoHS: Restriction on Hazardous Substances
S: Heavy-duty, rubber-insulated portable cord.
Stranded copper conductors with separator and
individual rubber insulation. Two or more color-
coded conductors cabled with filler, wrapped with
separator and rubber jacketed overall, 600 Volts.
SAE: Society of Automotive Engineers
SANZ: Standards Association of New Zealand
SBR: Styrene Butadiene Rubber
ScTP: Screened Twisted Pair
SDN: Switched Digital Network
217
Electronics
Technical Information
Abbreviations & Acronyms
SE: Service Entrance Cable, NEC Article 338
Cable Designation
SWR: Standing Wave Ratio
SYS: System
SEMKO: Approval agency for Sweden
SFTP: Simple File Transfer Protocol
SI: System Internationale
SJ: Junior hard-service, rubber-insulated pendant or
portable cord. Same construction as type S,
but 300V. Jacket thickness different.
SJO: Same as SJ, but carolprene, oil-resistant com-
pound outer jacket. Can also be made "water-
resistant." 300V, 60°C.
SJT: Junior hard service thermoplastic or rubber-
insulated conductors with overall thermoplastic
jacket, 300V, 60°C to 105°C.
SJTO: Same as SJT but oil-resistant thermo-
plastic outer jacket. 60°C.
SMTP: Simple Mail Transfer Protocol
SNA: Systems Network Architecture
SNM: Shielded Non Metallic Sheathed Cable, NEC
Article 337 Cable Designation
SNMP: Simple Network Management Protocol
SNR: Signal to Noise Ratio
SO: Hard-service cord, same construction as type
S except oil-resistant carolprene jacket, 600V,
60° to 90°C.
SONET: Synchronous Optical Network
SP-1: All rubber, parallel-jacketed, two-conductor
light-duty cord for pendant or portable use in
damp locations. 300V.
SP-2: Same as SP-1, but heavier construction,
with or without third conductor for grounding
purposes. 300V.
SP-3: Same as SP-23, but heavier construction for
refrigerators or room air conditioners. 300V.
SPC: Stored Program Control
TC: (1) Power and Control Tray Cable, NEC Article
340 Cable Designation (2) Telecommunications
Closet
TCP: Transmission Control Protocol
TDM: Time-Division Multiplexing
TEL: Telephone
TELCO: Telephone Company
TERM: Terminal or termination
TEW: Canadian Standard Association type
appliance wires. Solid or stranded single
conductor, plastic-insulated, 600V, 105°C.
TF: Fixture wire, thermoplastic-covered solid or
seven strands. 60°C.
TFE: Tetrafluoroethylene
TFF: Same as TF but flexible stranding. 60°C.
THHN: 90°C, 600V nylon jacketed building wire
THW: Thermoplastic vinyl-insulated building wire.
Flame-retardant, moisture- and heat-resistant.
75°C. Dry and wet locations.
THWN: Same as THW but with nylon jacket
overall. 75°C.
TIA: Telecommunications Industry Association
TOC: Tin Overcoat
TP: Transport Protocol
TP-PMD: Twisted Pair-Physical Medium Dependent
TPDDI: Twisted Pair Distributed Data Interface
TSB: Telecommunications System Bulletin
TT: Telephone Terminal
TTB: Telephone Terminal Board
TTY: Text Telephones
TW: Thermoplastic vinyl-jacketed building wire,
moisture-resistant. 60°C.
UCC: Uniform Code Council
SPG: Single Point Ground
UF: Thermoplastic underground feeder and
branch circuit cable
SPT-1: Same as SP-1, except all-thermoplastic.
300V. With or without third conductor for
grounding.
SPT-2: Same as SP-2, except all-thermoplastic.
300V. With or without third conductor for
grounding.
SPT-3: Same as SP-3, except all-thermoplastic.
300V. With or without third conductor for
grounding.
SRD: Portable range or dryer cable. Three or four
rubber-insulated conductors with rubber or
neoprene jacket, flat or round construction.
300V, 60°C.
SRDT: Same as SRD, except all-thermoplastic
with a maximum temperature of 90°C.
SRL: Structural return loss
ST: Hard-service cord, jacketed, same as type S
except all-plastic construction, 600V, 60°C to
105°C.
UF: Underground Feeder and Branch Circuit
Cable, NEC Article 339 Cable Designation
UG: Underground
UHF: Ultra High Frequency, 300 to 3,000 MHz
UL: Underwriter's Laboratories, Inc.
µm: Micron or micrometer
UPC: Universal Packaging Code
UPS: Uninterruptible Power Supply
USE: Underground Service Entrance Cable, NEC
Article 338 Cable Designation
UTE: Approval agency for France; Union
Technique de l'Electricite
UTP: Unshielded twisted-pair
V: Volt
VDE: West Germany approval agency
VHF: Very High Frequency, 30 to 300 MHz
VP: Velocity of Propagation
STA: Station
VSWR: Volume Standing Wave Radio
VW-1: A flammability rating established by
Underwriters Laboratories for wires and cables
that pass a specially designed vertical flame
test, (formerly designated FR-1)
W: Symbol for watt or wattage
WA: Work area
WP: Waterproof Outlet
X: Cross-connect
XLPE: Crosslinked polyethylene
Z: Symbol for impedance
STO: Same as ST but with oil-resistant thermo-
plastic outer jacket. 600V, 60°C.
STP: Shielded twisted pair
SV: Vacuum cleaner cord, two or three-conductor,
rubber-insulated. Overall rubber jacket. For light-
duty in damp locations. 300V, 60°C.
SVO: Same as SV except carolprene jacket, 300V,
60°C.
SVT: Same as SV except all-plastic construction.
With or without third conductor for grounding
purposes only. 300V, 60°C to 90°C.
SW: Station Wire
SWB: Switchboard
218
Technical Information
Electronics
Hook-Up Wire Product Finder
TEMP. °C
VOLTAGE
UL
UL
CSA
MIL
AWG
P/N
STRAND TYPE
PAGE
60
60
60
60
60
1500*
3000*
5000*
5000*
10000*
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
20
20
18
18
18
C1326
C1319
C1320A
C1321
C1318
STRANDED
STRANDED
STRANDED
STRANDED
STRANDED
7
7
7
7
7
80
80
80
80
80
80
80
1000
1000
1000
1000
1000
1000
1000
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
W-76B
W-76B
W-76B
W-76B
W-76B
W-76B
W-76B
24
22
20
18
16
14
12
C7600A
C7602A
C7604A
C7606A
C7608A
C7610A
C7611A
STRANDED
STRANDED
STRANDED
STRANDED
STRANDED
STRANDED
STRANDED
4
4
4
4
4
4
4
80/105
80/105
80/105
80/105
80/105
80/105
80/105
80/105
80/105
80/105
300
300
300
300
300
300
300
300
300
300
1007
1007
1007
1007
1007
1007
1007
1007
1007
1007
1569
1569
1569
1569
1569
1569
1569
1569
1569
1569
TR-64
TR-64
TR-64
TR-64
TR-64
TR-64
TR-64
TR-64
TR-64
TR-64
—
—
—
—
—
—
—
—
—
—
24
24
22
22
20
20
18
18
16
16
C2003A
C2015A
C2004A
C2016A
C2028A
C2040A
C2052A
C2064A
C2053A
C2065A
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
2
2
2
2
2
2
2
2
2
2
STRANDED
105
105
105
105
105
105
105
105
105
105
105
600
600
600
600
600
600
600
600
600
600
600
1015
1015
1015
1015
1015
1015
1015
1015
1015
1015
1015
—
—
—
—
—
—
—
—
—
—
—
TEW
TEW
TEW
TEW
TEW
TEW
TEW
TEW
TEW
TEW
TEW
—
—
—
—
—
—
—
—
—
—
—
24
22
22
20
20
18
18
16
14
12
10
C2100A
C2101A
C2117A
C2102A
C2118A
C2103A
C2119A
C2104A
C2105A
C2106A
C2107A
STRANDED
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
STRANDED
STRANDED
STRANDED
3
3
3
3
3
3
3
3
3
3
3
* For intermittent duty only
219
Electronics
Technical Information
Multi-Conductor Cable Product Finder
AWG 28
AWG 24
AWG 22
AWG 20
AWG 19
AWG 18
AWG 16
AWG 14
AWG 12
NO. STRAND
COND. TYPE
P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE
1
SOLID
STRANDED
743605 B ............169
743601 B ............169
743602 B ............169
743603 B ............169
743604 B ............169
C1300 B,R...........172
C1201 B,C...........175
C1301 B,R...........172
2
SOLID
C2515A F ..............23 C2509A F ............164 C2754A ...................9 C0471 U..............125 C0473 U..............125 C0475 U..............126 C0476 F ..............126
C2676A B..............34 C4311A C................9
C4008A U..........9, 43
C4167A F ..............29
C4408 U..............138
E1000S U ............134
E1482S U ............117
E2000S F.............135
E2100S F-P.........137
E2482S S ............119
E3000S U-P.........136
E3482S U-P.........121
E3542S F-P.........123
C0472 F ..............126 C0474 F ..............126 C0491 U..............125 C0492 U..............125
C3060 F-P.............28 C3168 F-P...........128 C3172 F-P...........128 C3174 F-P...........128
C3110 U-P.............17 C3210 U-P...........122 C3220 U-P...........122 C3224 U-P...........122
C3167 F-P...........128 C3241 U-P...........127 C3224 U-P...........122 C3246 U-P...........127
C3200 U-P...........122 C3270 F-P...........124 C3244 U-P...........127 C3282 F-P...........124
C3240 U-P...........127 C4321A U............118 C3280 F-P...........124 C4164A F ..............29
C3260 F-P...........124 C4344A F ............120 C4163A F ..............29 C4327A U............118
C4304A U............118 E1512S U ............117 C4324A U............118 C4348A F ............120
C4334A F ............120 E2404S U ............117 C4347A F ............120 E1532S U ............117
E1030S U ............134 E2522S F.............119 E1522S U ............117 E2542S F.............119
E1502S U ............117 E3512S U-P.........121 E2406S U ............117 E3532S U-P.........121
E2030S F.............135 E3612S F-P.........123 E2532S F.............119 E3632S F-P.........123
E2200S F-P.........137
E2402S U ............117
E2502S F.............119
E3030S U-P.........136
E3502S U-P.........121
E3602S F-P.........123
E3522S U-P.........121
E3622S F-P.........123
2
STRANDED C6500A B..............37 743701 B ............170 743706 B ............170 743707B .............170
743704 B ............170 C0431A U..............22 C0433A U..............22
743705 B ............170 C0450A F ..............32 C0452A F ..............32
C0740A F ..............68 C0760A F ..............69 C1302 B,R.....40, 172
C1226A S............173 C1322A B............174 C1360 U..............156
C1228A F ............172 C1362 U..............156 C1642A B..............35
C1356 U..............156 C2514A F ..............23 C2519A F ..............24
C2461A U..............11 C2516A F ..............23 C2524A F ..............23
C2513A F ..............23 C2518A F ..............24 C2540A F ..............23
C4152A F ..............29 C2520A F ..............24 C2681A B..............36
C4216A F ..............31 C2677A B..............34 C2888A S..............33
C2679A B..............36 C3320 F-P.............27
740302 U ............158 740202 U ...........158 740102 U ............158 740002 U ............158
C0435A U..............22 C0437A U..............22 C0439A U..............22 C0441A U..............22
C0454A F ..............32 C0456A F ..............32 C0458A F ..............32 C0460A F ..............32
C1202 B,C.....41, 175 C1358 U..............158 C1361 U..............156 C1363 U..............156
C1357 U..............156 C1602 B,C.....41, 175 C1612 B,C.............41 C1364 U..............157
C2521A F ..............24 C1704 U..............152 C1702 U..............152 C1700 U..............152
C2534A F ..............23 C2405A U..............14 C2409A U..............14 C2410A U..............14
C2686A B..............23 C2536A F ..............17 C2538A F ..............17 C2539A F ..............17
C2830A U..............13 C2895A S..............33 C3126 U-P.............16 C3129 U................17
C2892A S..............33 C3068 F-P.............28 C4146 U-P.............20 C4150A U..............20
C3062 F-P.............28 C3127 U-P.............17 C4201A F ..............30 C4202A F ..............30
C3102 U-P.............16 C3169 F-P.............27 C4215A F ..............30 E1062S U ............134
C3112 U-P.............17 C3193 U-P.............16 E1052S U ............134 E2062S F.............135
C3162 F-P.............27 C4135A U..............20 E2052S F.............135 E2262S F-P.........137
C4114A U..............18 C4162A F ..............29 E2252S F-P.........137 E3062S U-P.........136
C4125A U..............19 C4213A F ..............30 E3052S U-P.........136
C4155A F ..............29 C8111 FB-P...........39
C2882A S..............33 C3602 U-R.............21
C3105 U-P.............16 C4117A U..............19
C3115 U-P.............17 C4154A F ..............29
C3154 F-P.............27 C4166A F ..............30
C3158 F-P.............28 C4211A F ..............30
C4100A U..............18 C6311 UJ ............138
C4197A F ..............30 E1042S U ............134
C4153A F ..............29 C6351A U..............13
C4212A F ..............30 E2042S F.............135
C4168A F ..............29 E1022S U ............134
C5460 U..............139 E2242S F-P.........137
C4192A F ..............30 E2022S F.............135
C6312 UJ ............138 E3042S U-P.........136
C4210A F ..............30 E2122S F-P.........137
C6367 U..............157
C6310 UJ ............138 E3022S U-P.........136
C7102A UJ ..........156
C6348A U..............12
C8116 U-P.............45
E1002S U ............134
C8122 U-P.............45
E2002S F.............135
E1032S U ............134
E2102S F-P.........137
E2032S F.............135
E3002S U-P.........136
E2202S F-P.........137
E3032S U-P.........136
3
SOLID
C4410 U..............138 C2510A F ............164
C1201 B,C...........175 C4322A U............118 C4325A U............118
C1301 B,R...........172 C4345A F ............120
C3114 U-P.............17
C4305A U............118
C4335A F ............120
E1503S U ............117
E2503S S ............119
E3503S U-P.........121
E3603S F-P.........123
STRANDED C0530A FB ............72 C0680A FB ............72 C0432A U..............22 C0434A U..............15
C0939A FB ............70 C0741A F ..............68 C0451A F ..............32 C0781A F ..............69
C6501A B..............37 C0951A FB ............70 C0761A F ..............69 C1304 B,R.............40
C2462A U..............11 C0971A FB ............71 C1332A B..............36
C4217A F ..............31 C1335A S..............33 C1333A F ............159
C8115 FB-P...........39 C2517A F ..............23 C1643A B..............35
C2526A F ..............23 C2525A F ..............23
C0436A U..............22 C0438A U..............22 C0440A U..............22
C0455A F ..............32 C0457A F ..............32 C0459A F ..............32
C1203 B,C.............41 C1603 B,C.............41
C2535A F ..............23 C2406A U..............14
C2768A S..............33 C2537A F ..............23
C2831A U..............13 C3194 U-P.............16
C3064 F-P.............28 C3340 F-P.............27
C3120 U-P.............17 C4136A U..............20
C3164 F-P.............27 C4165A F ..............29
C3190 U-P.............16 C4200A F ..............30
C4126A U..............19 C8119 FB-P...........39
C4159A F ..............29 E1043S U ............134
C4198A F ..............30 E2043S F.............135
C8106 F-P.............26 E2243S F-P.........137
C8107 FB-P...........39 E3043S U-P.........136
E1033S U ............134
C2678A B..............36 C2528A F ..............23
C3310 F-P.............27 C3321 F-P.............28
C4062A U..............12 C3603 U,R.............21
C4101A U..............18 C4118A U..............19
C4156A F ..............29 C4157A F ..............29
C4169A F ..............29 C4158A F ..............29
C4193A F ..............30 C6352A U..............13
E1003S U ............154 E1023S U ............134
E2003S F.............135 E2023S F.............135
E2103S F-P.........137 E2123S F-P.........137
E2033S F.............135
E3003S U-P.........136 E3023S U-P.........136
E2203S F-P.........137
E3033S U-P.........136
* For intermittent duty only
®
®
B - BRAID SHIELD
IFB - INDIVIDUAL FLEXFOIL + FLEXFOIL /BRAID
P - PLENUM
R - RUBBER
S - SPIRAL SHIELD
U - NO SHIELD
UJ - UN-JACKETED
®
C - CAROLPRENE
®
F - FLEXFOIL SHIELD
®
FB - FLEXFOIL /BRAID SHIELD
®
I - INDIVIDUAL FLEXFOIL SHIELD
220
Technical Information
Electronics
Multi-Conductor Cable Product Finder
AWG 28
AWG 24
AWG 22
AWG 20
AWG 19
AWG 18
AWG 16
AWG 14
AWG 12
NO. STRAND
COND. TYPE
P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE
4
SOLID
C4412 U..............138
E1001S U ............134
E1484S U ............117
E2484S F.............119
E3001S U-P.........136
C0485 U..............125 C0486 U..............125 C0496 F ..............126 C0497 F ..............126
C0494 F ..............126 C3171 F-P...........128 C3173 U-P...........128 C3175 F-P...........128
C3061 F-P.............28 C3211 U-P...........122 C3223 U-P...........122 C3225 U-P...........122
C3111 U-P.............17 C3243 U-P...........127 C3245 U-P...........127 C3247 U-P...........127
C3170 F-P...........128 C3271 F-P...........124 C3284 F-P...........124 C3283 F-P...........124
C3201 U-P...........122 C4323A U............118 C4326A U............118 E1534S U ............117
C3242 U-P...........127 C4346A F ............120 E1524S U ............117 E2544S F.............119
C3261 F-P...........124 E1514S U ............117 E2534S F.............119 E3534S U-P.........121
C4306A U............118 E2524S F.............119 E3524S U-P.........121 E3634S F-P...........12
C4336A F ............120 E3514S U-P.........121 E3624S F-P.........123
E1504S U ............117 E3614S F-P.........123
E2504S F.............119
E3504S U-P.........121
E3604S F-P.........123
STRANDED C0531A FB ............72 C0681A FB ............72 C0762A F ..............69 C0782A F ..............69
C0940A FB ............70 C0742A F ..............68 C0972A FB ............71 C1119 U..............139
C6502A B..............37 C0952A FB ............70 C1118 U..............139 C1305 B,R.............40
C2463A U..............11 C1337A S..............33 C1331A F ............160
C4218A F ................3 C1340A F ............160 C1343A F ............160
C2523A F ..............23 C1644A B..............35
740304 U ............158 740204 U ............158 740104 U ............158 740004 U ............158
C0444A U..............22 C1604 B,C.............41 C1614 B,C.............41 C1701 U..............152
C1123 U..............139 C1705 U..............152 C1703 U..............152 C2440A U..............14
C1204 B,C.............41 C2425A U..............14 C2430A U..............14 C4151A U..............20
C2404A U..............13 C3195 U-P.............16 C4147A U..............20 E1064S U ............134
C2543A F ..............25 C3341 F-P.............27 E1054S U ............134 E2064S F.............135
C2688A B..............36 C4137A U..............20 E2054S F.............135 E2264S F-P.........137
C3063 F-P.............28 E1044S U ............134 E2254S F-P.........137 E3064S U-P.........136
C3103 U-P.............16 E2044S F.............135 E3054S U-P.........136
C3113 U................17 E2244S F-P.........137
C2680A B..............36 C2555A F ..............23
C3106 U-P.............16 C2683A B..............36
C3116 U-P.............17 C3322 F-P.............27
C3155 F-P.............27 C3604 U,R.............21
C3159 F-P.............28 C4119A U..............19
C3163 F-P.............27 E3044S U-P.........136
C4063A U..............12 C4161A F ..............29
C4127A U..............19
C4102A U..............18 C4196A F ..............30
C4204A F ..............30
C4160A F ..............29 C5078 U..............139
C5084 U..............139
C4194A F ..............30 C6353A U..............13
C8102 U-P.............15
C5076 U..............139 E1024S U ............134
C8110 FB-P...........39
E1004S U ............134 E2024S F.............135
C8114 F-P.............26
E2004S F.............135 E2124S F-P.........137
E1034S U ............134
E2104S F-P.........137 E3024S U-P.........136
E2034S F.............135
E3004S U-P.........136
E2204S F-P.........137
E3034S U-P.........136
5
SOLID
C3117 U-P.............17 C4349A U............118
C4307A U............118 C4350A F ............120
C4337A F ............120
STRANDED C0532A FB ............72 C0682A FB ............72 C0973A FB ............71 C1126 U..............139
C0941A FB ............70 C0753A F ..............68 C1124 U..............139 C1308 B,R.............40
C0953A FB ............70 C4064A U..............12 C1645A B..............35
C2464A U..............11 C4103A U..............18 C3605 U,R.............21
C4219A F ..............31 C5086 U..............139 C4120A U..............19
C6355A U..............13
C2420A U..............13 C2434A U..............14 C2437A U..............14
C4128A U..............19 C4138A U..............20 C4148A U..............20
6
SOLID
C4300A U............118
C3118 U-P.............17
C4308A U............118
C4338A F ............120
E1506S U ............117
E2506S F.............119
E3506S U-P.........121
E3606S F-P.........123
STRANDED C0533A FB ............72 C0683A FB ............72 C0763A F ..............69 C0783A F ..............69
C0942A FB ............70 C0743A F ..............68 C0974A FB ............71 C1310 B,R.............40
C6503A B..............37 C0954A FB ............70 C1341A S..............33 C1646A B..............35
C1345A F ............159 C3311A F-P...........27 C3606 U,R.............21
C2466A U..............11 C4066 U................12
C1206 B,C.............41 C1606 B,C.............41
C3065 F-P.............28 C8108 FB-P...........39
C3121 U-P.............17
C3166 F-P.............27
C3192 U-P.............16
C4220A F ..............31 C4104A U..............18
C4205A F ..............30
C4207A F ..............30
C4206A U..............19
E1006S U ............134
C8120 FB-P...........39
E2006S F.............135
E1036S U ............134
E2106S F-P.........137
E2036S F.............135
E3006S U-P.........136
E2206S F-P.........137
E3036S U-P.........136
7
8
SOLID
C4309A U............118
C4339A F ............120
STRANDED C0534A FB ............72 C0684A FB ............72 C0975A FB ............71 C1312 B,R.............40
C0943A FB ............70 C0754A F ..............68 C4088A U..............12 C3607 U,R.............21
C0955A FB ............70 C4105A U..............18 C4121A U..............19
C2421A U-P...........13 C2426A U..............14 C2431A U..............14
C4129A U..............19 C4139A U..............20 C4149A U..............20
C2488A U..............11
C4221A F ..............31
C6356A U..............13
SOLID
C3119 F ................17
C4310A U............118
C4340A F ............120
E1508S................117
E2508S................119
STRANDED C0535A FB ............72 C0685A FB ............72 C0764A F ..............69 C0784A F ..............69
C1208 B,C.............41 C1608 B,C.............41
C3122 U-P.............17 C2443A U..............14
C3180 F-P.............27 C4140A U..............20
C3191 U-P.............16
C0944A FB ............70 C0744A F ..............68 C0976A FB ............71 C1313 B,R.............40
C6504A B..............37 C0956A FB ............70 C1130A U............139 C1648A FB ............38
C2465A U..............11 C4065A U..............12 C3608 U,R.............21
C4222A F ..............31 C4080 U..............139 C4090 U..............139
C4106A U..............18
E1038S U ............134
E2038S F.............135
C4208A F ..............30
E2208S F-P.........137
C5096 U..............139
E3038S U-P.........136
E1008S U ............134
E2008S F.............135
E2108S F-P.........137
E3008S U-P.........136
®
®
B - BRAID SHIELD
IFB - INDIVIDUAL FLEXFOIL + FLEXFOIL /BRAID
P - PLENUM
R - RUBBER
S - SPIRAL SHIELD
U - NO SHIELD
UJ - UN-JACKETED
®
C - CAROLPRENE
®
F - FLEXFOIL SHIELD
®
FB - FLEXFOIL /BRAID SHIELD
®
I - INDIVIDUAL FLEXFOIL SHIELD
221
Electronics
Technical Information
Multi-Conductor Cable Product Finder
AWG 28
AWG 24
AWG 22
AWG 20
AWG 19
AWG 18
AWG 16
AWG 14
AWG 12
NO. STRAND
COND. TYPE
P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE
9
SOLID
C4312A U............118
C4341A F ............120
STRANDED C0536A FB ............72 C0686A FB ............72 C0977A FB ............71 C4122A U..............19
C2422A U..............13 C2435A U..............14
C4130A U..............19 C4141A U..............20
C0945A FB ............70 C0755A F ..............68 C4070A U..............12 C6357A U..............13
C0957A FB ............70 C4107A U..............18
C2470A U..............11
C4223A F ..............31
10
SOLID
C2511A F ............164
C4313A U............118
C4342A F ............120
STRANDED C0537A FB ............72 C0687A FB ............72 C0765A F ..............69 C0785A F ..............69
C0946A FB ............70 C0745A F ..............68 C0978A FB ............71 C3610 U,R.............21
C6505A B..............37 C0958A FB ............70 C4071A U..............12 C4123A U..............19
C2471A U..............11 C4108A U..............18
C1210 B,C.............41
C3178 U-P.............16
C3181 F-P.............27
E1040S U ............134
E2040S F.............135
E1010S U ............134
E2010S F.............135
11
12
SOLID
C4314A U............118
STRANDED
SOLID
STRANDED C6506A B..............37 C2467A U..............11 C4067A U..............12 C6360A U..............13
C1212 B,C.............41 C2427A U..............14
C2412A U..............13 C4142A U..............20
C3179 U-P.............16
C4109A U..............18
E1012S U ............134
E2012S F.............135
C3182 F-P.............27
C4131A U..............19
E1041S U ............134
E2041S F.............135
15
SOLID
C4301A U............118
C4315A U............118
STRANDED C0538A FB ............72 C0688A FB ............72 C0766A F ..............69 C6358A U..............13
C0947A FB ............70 C0746A F ..............68 C0979A FB ............71 C0786A F ..............69
C6507A B..............37 C0959A FB ............70 C4073A U..............12 C4124A U..............19
C2473A U..............11 C4110A U..............18
C2423A U..............13 C2428A U..............14
C4132A U..............19 C4143A U..............20
C4225A F ..............31
18
19
SOLID
STRANDED
SOLID
C4111A U..............18
STRANDED
C2424A U..............13 C2429A U..............14
C4133A U..............19 C4144A U..............20
20
SOLID
C4302A U............118
C4316A U............118
STRANDED C6508A B..............37 C0747A F ..............68 C0767A F ..............69 C0787A F ..............69
C0960A FB ............70 C0980A FB ............71
C4226A F ..............31 C4075A U..............12
C4112A U..............18
21
25
SOLID
C4317A U............118
STRANDED
SOLID
STRANDED C0948A FB ............41 C0748A F ..............68 C0768A F ..............69 C0788A F ..............69
C0961A FB ............70 C0981A FB ............71
C2433A U..............13 C2436A U..............14
C4134A U..............19 C4145A U..............20
C4227A F ..............31 C4076A U..............12
C4113A U..............18
30
SOLID
C4318A U............118
C4343A F ............120
STRANDED
C0749A F ..............68 C4077A U..............12
C4228A F ..............31 C4114A U..............18
40
50
SOLID
STRANDED
C0750A F ..............68 C4079A U..............12
C4229A F ..............31 C4116A U..............18
SOLID
STRANDED
C0751A F ..............68 C4079A U..............12
C4230A F ..............31 C4116A U..............18
®
®
B - BRAID SHIELD
IFB - INDIVIDUAL FLEXFOIL + FLEXFOIL /BRAID
P - PLENUM
R - RUBBER
S - SPIRAL SHIELD
U - NO SHIELD
UJ - UN-JACKETED
®
C - CAROLPRENE
®
F - FLEXFOIL SHIELD
®
FB - FLEXFOIL /BRAID SHIELD
®
I - INDIVIDUAL FLEXFOIL SHIELD
222
Technical Information
Electronics
Multi-Paired Cable Product Finder
AWG 28
SHIELD
AWG 24
SHIELD
AWG 23
SHIELD
AWG 22
SHIELD
AWG 20
SHIELD
AWG 18
NO. STRAND
PAIRS TYPE
P/N
PAGE P/N
PAGE P/N
PAGE P/N
PAGE P/N
PAGE P/N
SHIELD
PAGE
1
SOLID
C4008A U...........................9, 43
STRANDED
740601 IF.............................166
740501 IF.............................167
740701 IF.............................168
C0600A F ...............................73
C0841A FB .............................76
C4841A FB .............................76
C4170A F ...............................53
C4209A F ...............................53
C8117 FB-P............................57
C8127 F-P..............................51
C3204 F-P .............................48
C0720A F ...............................73
C4183A F ...............................54
C7104A F ...............................46
C7112A FB .............................66
C8103 F-P..............................49
C8109 F-P..............................49
C8124 F-P..............................51
C8126 F-P..............................51
C6101A U...............................44
C8101 F-P..............................49
C8104 F-P..............................49
C8123 F-P..............................51
2
SOLID
C4413 U...............................138
C1670A F ...............................46
C4010A U...............................43
STRANDED
C0804A FB .............................79 C0515A FB .............................78
C0601A F ...............................73
C0620A FB .............................75
C0829A FB .............................77
C0842A FB .............................76
C0890A F ...............................74
C0910A IF...............................83
C0924A IFB ............................84
C3028 F-P..............................56
C3150 F-P..............................48
C3214 F-P..............................55
C4171A F ...............................53
C4842A F ...............................76
C8118 F-P..............................50
C8128 IF-P.............................64
C8129 FB-P............................57
C8134 IF-P.............................62
C0550A F ...............................66 C7106A IF...............................58 C0560A F ...............................66
C0570A IF...............................65
C0650A FB .............................75
C0721A F ...............................73
C1338A B.............................161
C1350A IF...............................60
C1352A IF...............................58
C1353A IF...............................58
C3156 IF-P.............................61
C3205 F-P..............................48
C3352 F-P..............................52
C4184A F ...............................54
C4203A IF...............................59
C6010A U...............................43
C7114A FB .............................66
C8105 IF-P.............................62
C8112 IF-P.............................63
C0584A IF...............................65
C3362 F-P..............................52
C6118A U...............................44
3
SOLID
C4328A U.............................129
C6035A F ...............................81
STRANDED
C0805A FB .............................79 C0516A FB .............................78
C0602A F ...............................73
C0621A FB .............................75
C0830A FB .............................77
C0843A FB .............................76
C0901A F ...............................74
C0911A IF...............................83
C0925A IFB ............................84
C3029 F-P..............................56
C3153 F-P..............................48
C3215 F-P..............................55
C4172A F ...............................53
C4843A FB .............................76
C6065A IF...............................82
C8113 F-P..............................51
C0551A F ...............................66 C6052A IF...............................82 C0561A F ...............................66
C0571A IF...............................65 C6061A IF.............................165 C0585A IF...............................65
C0651A FB .............................75
C0722A F ...............................73
C3157 IF-P.............................61
C3206 F-P..............................48
C3353 F-P..............................52
C4185A F ...............................54
C6014A U...............................43
C6040A IF...............................82
C7116A FB .............................66
C8131 IF-P.............................62
C8132 IF-P.............................63
C6047A IF...............................82
C6103A U...............................44
4
SOLID
E1842S U .............................162 E1843S U .............................162 C1676A F ...............................46
E3842S UP ...........................162 E3843S UP ...........................162 C4015A U...............................43
STRANDED
C0806A FB .............................79 740604 IF.............................166
740504 IF.............................167
740704 IF.............................168
C0517A FB .............................78
C0603A F ...............................73
C0831A FB .............................77
C0844A FB .............................76
C0893A F ...............................74
C0912A IF...............................83
C0926A IFB ............................84
C3030 F-P..............................56
C3151 F-P..............................48
C3216 F-P..............................55
C4173A F ...............................53
C4844A FB .............................76
C0552A F ...............................66 C1368A IF...............................80 C0562A F ...............................66
C0572A IF...............................65
C0652A FB .............................75
C0723A F ...............................73
C3207 F-P..............................48
C3354 F-P..............................52
C4186A F ...............................54
C0586A IF...............................65
C3364 F-P..............................52
C6119 U.................................44
4.5 SOLID
STRANDED
SOLID
STRANDED
C3217 F-P..............................55
5
C6120A U...............................31
C0807A FB .............................79 C0518A FB .............................78
C0604A F ...............................73
C0653A FB .............................75
C0724A F ...............................73
C4187A F ...............................54
C0623A FB .............................75
C0832A FB .............................77
C4174A F ...............................53
®
®
B - BRAID SHIELD
IFB - INDIVIDUAL FLEXFOIL + FLEXFOIL /BRAID
P - PLENUM
R - RUBBER
S - SPIRAL SHIELD
U - NO SHIELD
UJ - UN-JACKETED
®
C - CAROLPRENE
®
F - FLEXFOIL SHIELD
®
FB - FLEXFOIL /BRAID SHIELD
®
I - INDIVIDUAL FLEXFOIL SHIELD
223
Electronics
Technical Information
Multi-Paired Cable Product Finder
AWG 28
SHIELD
AWG 24
SHIELD
AWG 23
SHIELD
AWG 22
SHIELD
AWG 20
AWG 18
SHIELD PAGE
NO. STRAND
PAIRS TYPE
P/N
PAGE P/N
PAGE P/N
PAGE P/N
PAGE P/N
SHIELD
PAGE P/N
6
SOLID
C1671A F ...............................46
C4329A U.............................129
C6036A IF...............................81
C4333A U.............................129
STRANDED
740706 IF.............................168
C0519A FB .............................78
C0605A F ...............................73
C0624A FB .............................75
C0839A FB .............................77
C0899A F ...............................74
C0913A IF...............................83
C3031 F-P..............................56
C3165 F-P..............................48
C3218 F-P..............................55
C4175A F ...............................53
C6066A IF...............................82
C0553A F ...............................66 C6053A IF...............................82 C0563A F ...............................66
C0573A IF...............................65 C6062A IF.............................165 C0587A IF...............................65
C0654A FB .............................75
C0725A F ...............................73
C3208 F-P..............................48
C3356 F-P..............................52
C4188A F ...............................54
C6017A U...............................43
C6041A IF...............................82
C6048A IF...............................82
C6106A U...............................44
7
8
SOLID
STRANDED
C0808A FB .............................79 C0520A FB .............................78
C0606A F ...............................73
C0655A FB .............................75
C0656A FB .............................75
C0625A FB .............................75
C0833A FB .............................77
C4176A F ...............................53
SOLID
STRANDED
740608 IF.............................166
740508 F..............................167
740708 IF.............................168
C0521A FB .............................78
C0607A F ...............................73
C0626A FB .............................75
C4177A F ...............................53
C6121A U...............................44
9
SOLID
C1672A F ...............................46
STRANDED
740709 IF.............................168
C0608A F ...............................73
C0914A IF...............................83
C4178A F ...............................53
C6067A IF...............................82
C0554A F ...............................66 C6054A IF...............................82 C0564A F ...............................66
C0574A IF...............................65
C0726A F ...............................73
C4189A F ...............................54
C6042A IF...............................82
C0588A IF...............................65
C6049A IF...............................82
C6109A U...............................44
10
SOLID
STRANDED
C0810A FB .............................79 C0522A FB .............................78
C0609A F ...............................73
C0658A FB .............................75
C0628A FB .............................75
C0835A FB .............................77
C4179A F ...............................53
11
12
SOLID
STRANDED
SOLID
C0915A IF...............................83
C6043A IF...............................82
C4330A U.............................129
STRANDED
C0812A FB .............................79 740512 IF.............................167
740612 IF.............................166
C6059A IF...............................82 C6056A IF...............................82 C6050A IF...............................82
740712 IF.............................168
C0836A FB .............................77
C0916A IF...............................83
12.5 SOLID
STRANDED
C0523A FB .............................78
C0630A FB .............................75
C0897A F ...............................74
C3152 F-P..............................48
C0660A FB .............................75
15
SOLID
C1673A F ...............................46
C4331A U.............................129
STRANDED
C0524A FB .............................78
C0610A F ...............................73
C0917A IF...............................83
C4180A F ...............................53
C0728A F ...............................73 C6058A IF...............................82 C6051A IF...............................82
C4190A F ...............................54
C6044A IF...............................82
®
®
B - BRAID SHIELD
IFB - INDIVIDUAL FLEXFOIL + FLEXFOIL /BRAID
P - PLENUM
R - RUBBER
S - SPIRAL SHIELD
U - NO SHIELD
UJ - UN-JACKETED
®
C - CAROLPRENE
®
F - FLEXFOIL SHIELD
®
FB - FLEXFOIL /BRAID SHIELD
®
I - INDIVIDUAL FLEXFOIL SHIELD
224
Technical Information
Electronics
Multi-Paired Cable Product Finder
AWG 28
SHIELD
AWG 24
SHIELD
AWG 23
SHIELD
AWG 22
SHIELD
AWG 20
SHIELD
AWG 18
NO. STRAND
PAIRS TYPE
P/N
PAGE P/N
PAGE P/N
PAGE P/N
PAGE P/N
PAGE P/N
SHIELD
PAGE
16
SOLID
STRANDED
740516 IF.............................167
740616 IF.............................166
740716 IF.............................168
17
18
19
SOLID
STRANDED
SOLID
C6060A IF...............................82
C6045A IF...............................82
STRANDED
SOLID
C0525A FB .............................78
STRANDED
C0611A F ...............................73
C4181A F ...............................53
20
25
SOLID
STRANDED
740520 IF.............................167
740620 IF.............................166
740720 IF.............................168
SOLID
STRANDED
C0526A FB .............................78
C0612A F ...............................73
C4182A F ...............................53
27
28
SOLID
C4332A U.............................129
C6046A IF...............................82
STRANDED
SOLID
STRANDED
740528 IF.............................167
740728 IF.............................168
42
SOLID
STRANDED
740542 IF.............................167
740742 IF.............................168
51
52
SOLID
C6451A F ...............................47
STRANDED
SOLID
STRANDED
740552 IF.............................167
740742 IF.............................168
®
®
B - BRAID SHIELD
IFB - INDIVIDUAL FLEXFOIL + FLEXFOIL /BRAID
P - PLENUM
R - RUBBER
S - SPIRAL SHIELD
U - NO SHIELD
UJ - UN-JACKETED
®
C - CAROLPRENE
®
F - FLEXFOIL SHIELD
®
FB - FLEXFOIL /BRAID SHIELD
®
I - INDIVIDUAL FLEXFOIL SHIELD
225
Electronics
Technical Information
NEC/CEC Substitution Chart
Communication wire and cable for
NEC ARTICLE
FREE RESISTANCE LEVEL
TEST REQUIREMENT
premise installations in accordance
with Article 800, and other applicable
parts of the National Electrical Code
(NEC), latest issue. Communication
wire and cables for Canada are in
accordance with the harmonized
Canadian Standard Association
C22.2 No. 214, Underwriters
800
725
760
820
NFPA 262 (Steiner Tunnel)
CSA-CMP (Steiner Tunnel)
CL3P
CL2P
(Highest) Plenum Cables
CMP
FPLP CATVP
Riser Cables
Multiple Floors
UL-16666 (Vertical Shaft)
CSA-CMG (Vertical Tray)
CL3R
CL2R
FPLR CATVR
FPL CATV
CATVX
General-Purpose Cables UL-1581 (Vertical Tray)
CMG CL3
(Lowest) Residential
Cables Restricted Use
CSA-CMG (Vertical Tray)
UL-1581 VW-1
CL2
CMX
CL3X
Laboratories UL 444, latest issue.
Notes: 1. Cables with a higher fire resistance level may be substituted for those with a lower fire resistance level.
2. Non-fire rated outside plant telephone cables may not run outside of a rigid metal conduit more than 50 feet from
the point of entrance into a building.
Figure 800-53, Cable Substitution Hierarchy
3. Cables rated cmg or cm may be used in runs penetrating one floor. (nec 800-53)
Plenum
CMP
ARTICLE 800
Table 800-53. Cable Uses and Permitted Substitutions
Riser
CMR
CABLE TYPE
CMP (FT-6)
CMR (FT-4)
USE
REFERENCE PERMITTED SUBSTITUTIONS
800-53 (a)
Communications
plenum cable
General Purpose
CMG
CM
Communications
riser cable
*
800-53 (b) CMP
CMG (FT-4)
CM (FT-1)
Communications
general purpose cable
800-53 (c) CMP, CMR, MPG, MP
800-53 (d) CMP, CMR, CMG, CM
Dwellings
CMX
Communications cable,
limited use
CMX (FT-1)
Type CM — Communications cables
Note: See Figure 800-53, Cable Substitution Hierarchy
A
B
→
Cable A shall be permitted to be used in
place of Cable B
*CMG can be substituted CM—CM can be substituted for CMG
ARTICLE 725
Table 725-61. Cable Uses and Permitted Substitutions
CABLE TYPE
USE
REFERENCE
PERMITTED SUBSTITUTIONS
Figure 725-61, Cable Substitution Hierarchy
Class 3 plenum cable
Class 2 plenum cable
Class 3 riser cable
Class 2 riser cable
725-61(a) CMP
CL3P
CL2P
CL3R
CL2R
Plenum
CMP
CL3P
CL2P
725-61(b) CMP, CL3P
725-61(b) CMP, CL3P, CMR
725-6 (b) CMP, CL3P, CL2P, CMR, CL3R
Riser
CMR
CL3R
CL2R
725-61(c)
and (d)
Power-limited tray cable
Class 3 cable
PLTC
CL3
725-61(b), CMP, CL3P, CMR, CL3R, CMG,
(e) and (f) CM, PLTC
General Purpose
PLTC
725-61(b), CMP, CL3P, CL2P, CMR, CL3R,
(c) and (f) CL2R, CMG, CM, PLTC, CL3
Class 2 cable
CL2
CMG
CM
CL3
CL2
725-61(b) CMP, CL3P, CMR, CL3R, CMG,
Dwellings
Class 3 cable, limited use
CL3X
CMX
CL3X
CL2X
and (e)
CM, PLTC, CL3, CMX
CMP, CL3P, CL2P, CMR, CL3R,
CL2R, CMG, CM, PLTC, CL3,
CL2, CMX, CL3X
725-61(b)
and (e)
Class 2 cable, limited use
CL2X
Type CM — Communications wires and cables
Type CL2 and CL3 — Class 2 and Class 3
remote-control, signaling and
Note: See Figure 725-61, Cable Substitution Hierarchy
power-limited cables
Type PLTC — Power-limited tray cable
A
B
→
Cable A shall be permitted to be used in
place of Cable B
Reprinted with permission from NFPA 70-2008 National Electrical Code ®, copyright © 2008, National Fire
Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of
the NFPA on the referenced subject, which is represented only by the standard in its entirety.
National Electrical Code® and the NEC© are registered trademarks of the NFPA.
226
Technical Information
Electronics
NEC/CEC Substitution Chart
Figure 760-154 (D), Cable Substitution Hierarchy Article 760
Table 760-154 (D). Cable Uses and Permitted Substitutions
Multiconductor
Cables
PERMITTED SUBSTITUTIONS
MULTICONDUCTOR
Plenum
Riser
CABLE TYPE
USE
REFERENCES
CMP
FPLP
FPLR
Power-limited fire alarm
plenum cable
760-154 (A)
CMP
FPLP
CMR
Power-limited fire alarm
riser cable
760-154 (B)
760-154 (C)
CMP, FPLP, CMR
FPLR
FPL
Power-limited fire alarm
cable
CMP, FPLP, CMR, FPLR,
CMG, CM
General Purpose
CMG
CM
FPL
Note: See Figure 760-154 (D), Cable Substitution Hierarchy
Type CM — Communications wires and cables
Type FPL — Power-limited fire alarm cables
A
B
→
Cable A shall be permitted to be used in
place of Cable B
No. 26 AWG minimum
Figure 820-154 (E), Cable Substitution Hierarchy Article 820
Table 820-154 (E). Coaxial Cable Uses and Permitted Substitutions
Plenum
CMP
CATVP
BLP
CABLE TYPE
USE
REFERENCES
PERMITTED SUBSTITUTIONS
Coaxial plenum cable
820-154 (A)
CMP, BLP
CATVP
Riser
BMR, BLP,
BLR
CMR
CATVR
Coaxial riser cable
820-154 (B)
820-154 (C)
CATVP, CMP, CMR,
BMR, BLP, BLR
CATVR
CATV
General Purpose
Dwellings
BMR, BM,
BLP, BLR,
BL
CMG
CM
CATV
Coaxial general purpose
cable
CATVP, CMP, CATVR,
CMR, CMG, CM, BMR,
BM, BLP, BLR, BL
BMR, BM,
BLP, BLR,
BL, BLX
CMX
CATVX
Coaxial cable, limited use
820-154 (C)
CATVP, CMP, CATVR,
CMR, CATV, CMG, CM,
BMR, BM, BLP, BLR,
BL, BLX
CATVX
Type BL — Network-powered broadband
communications low-power cables
Type BM — Network-powered broadband
Note: See Figure 820-154 (E), Cable Substitution Hierarchy
communications medium-power cables
Type CATV — Community antenna television cables
Type CM — Communications cables
A
B
→
Coaxial Cable A shall be permitted to be
used in place of Coaxial Cable B
Reprinted with permission from NFPA 70-2002 National Electrical Code ®, copyright © 2008, National Fire
Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of
the NFPA on the referenced subject, which is represented only by the standard in its entirety.
National Electrical Code® and the NEC© are registered trademarks of the NFPA.
227
Electronics
Technical Information
Agency Symbols
UL Listed Mark for the United States
CSA CMP
CSA CMG
CSA CMH
UL Listed Mark for Canada
UL Listed Mark for Canada and
the United States
NFPA 262 and CSA FT-6
Steiner Tunnel Fire Tests
UL Recognized Component Mark for
the United States
TIA/EIA 568A Cat. 3
UL Vertical Tray Flame Test
UL 1666 Riser Flame Test
IMSA
TIA/EIA 568B Cat. 5e & Cat. 6
California State Fire Marshal
RoHS Compliant Directive
2002/95/EC
228
Technical Information
Electronics
Agency Approval Index
AGENCY
PAGE(S)
CSA Type TEW............................................................................ 3, 5
CSA TR-64 ...................................................................................... 2
CSA Type LVT.............................................................................. 141
MIL-W-16878 TYPE B................................................................... 37
MIL-W-76B...................................................................................... 4
UL Type AWM...............................................................................5-6
UL Type CL2................................................................................ 142
UL Type MTW...............................................................................5-6
UL Type TFF.................................................................................... 5
UL Type THW .................................................................................. 6
UL Type 1007 .......................................................................... 2, 156
UL Type 1015 .................................................................................. 3
UL Type 1569 .................................................................................. 2
UL Type 2092 .......................................................................... 23, 35
UL Type 2093 ................................................................. 23, 35, 159
UL Type 2094 ....................................................23, 35, 38, 160-161
UL Type 2095 ....................................................33, 36, 47, 159-160
UL Type 2106 ................................................................................ 23
UL Type 2107 ................................................................................ 23
UL Type 2448 ................................................................................ 74
UL Type 2464 .........................................9-14, 18-20, 23, 25, 30-31,
43-44, 53-54, 58, 60, 65-66,
68-71, 73, 75, 81
UL Type 2493 ...........................................................................83-84
UL Type 2576 .....................................................................11-13, 60
UL Type 2587 ................................................................................ 14
UL Type 2717 ................................................................................ 58
UL Type 2835 ........................................................................ 58, 160
UL Type 2919 ...............................................................72, 76-78, 82
UL Type 2960 ................................................................................ 79
Jacket
Color Code Chart
Put-Ups
CODE
1
2
3
4
COLOR
BLACK
WHITE
CODE
R5/15
R8/18
21
30
35
PACKAGING
250' Spool
500' Spool
1000' Spool
1000' Spooless Pull-Pac® Carton
250' Reel
RED
ORANGE
YELLOW
GREEN
5
6
500' Reel
38
DARK BLUE
BROWN
GREY
1000' Reel
2500' Reel
5000' Reel
250' Coil
Factory Reel
Spool-Pac® 1000'
7
8
41
44
46
85
99
A3
10
13
16
19
77
PINK
LIGHT BLUE
PURPLE
WHT/BLK/BLU
229
Electronics
Technical Information
Put-Ups and Color Codes
PUT-UP CODES
JACKET COLOR CODES
PUT-UP
CODE
PUT-UP
CODE
COLOR
CODE
COLOR
CODE
PACKAGING
PACKAGING
JACKET COLOR
JACKET COLOR
58
59
60
61
62
63
64
65
66
67
68
69
70
73
74
75
76
77
78
79
80
85
86
88
89
90
91
92
93
94
96
99
XX
12 ft Sleeve w/connectors
25 ft Sleeve w/connectors
Cord Hanked, coil w/cuff
Cord Set Box
Cord Set Bag
Cord Set Sleeve
50 ft Sleeve w/connectors
100 ft Sleeve w/connectors
50 ft Cuff
100 ft Cuff
3500 ft Reel
46
47
48
49
50
56
62
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
86
88
90
91
92
93
96
97
98
99
Orange/Black
Yellow/White
Yellow/Black
Blue/White
3 ft Coax w/Connector HD
6 ft Coax w/Connector HD
50 ft Spool
100 ft Spool
Clamshell
250 ft Spool
500 ft Spool
900 ft Spool
1000 ft Spool
2500 ft Spool
500 ft Pull-Pac
5000 ft Spool
500 ft Pull-Pac
1000 ft Pull-Pac
1000 ft Pull-Pac
150 ft Reel
100 ft Reel
200 ft Coil
250 ft Reel
300 ft Reel
Uninsulated
Black
White
Red
Orange
Yellow
Green
Dark Blue
Brown
Maroon
03
06
11
12
13
15
18
20
21
24
25
26
27
30
31
32
33
34
35
36
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
31
33
34
35
36
37
38
39
40
41
42
43
44
45
Blue/Black
Black w/White Trace
Silver Gray (Lt Gray)
Light Green
Lime Green
Birch
Maple
Walnut
Wrought Iron
Copper
White/Black/Red
White/Black/Orange
White/Black/Yellow
White/Black/Green
White/Black/Blue
White/Black/Brown
White/Black/Violet
White/Black/Gray
Black/Red/White
Orange/Green/Black
Natural
Tan
Clear
Clear Brown
Clear Blue
Clear Red
Gray
Antique Gold
Ivory
Retail Spool-Pac
Cord Hanked, coil w/cuff
Cord Set, long length
12' Clamshell w/connectors
25' Clamshell w/connectors
50' Clamshell w/connectors
100' Clamshell w/connectors
15,000 ft Reel
8,000 ft Reel
Blister Pack w/connectors
250 ft Coil
500' Shrinkwrap coil
12' Sleeve w/o connector
25' Sleeve w/o connector
50' Sleeve w/o connector
75' Sleeve w/o connector
100' Sleeve w/o connector
Bulk Reel
Display
Wiring Device, Skin Pack
Factory Reel
Pink
Light Green
Clear Gold
Light Blue
Beige
Light Brown
Purple
500 ft Reel
Clear Silver
Light Purple
Neon Green
Mint Green
Raspberry
Gold
White/Black
White/Red
White/Orange
White/Yellow
White/Green
White/Blue
White/Brown
White/Violet
White/Gray
Red/Green
Green/White
Blue/Red
Blue/White
Orange/Red
500 Meter (1640')
Long Length Reel
1000 ft Reel
1500 ft Reel
2000 ft Reel
2500 ft Reel
4000 ft Reel
5000 ft Reel
7500 ft Reel
10,000 ft Reel
1600 ft Reel
1000 Meter (3280')
4500 ft Reel
3000 ft Reel
25 ft Cuff
12 ft Clamshell
25 ft Clamshell
50 ft Clamshell
100 ft Clamshell
Twisted Cond. No Jkt
1 Stripe
2 Stripes
Various Lengths
Assorted Colors
A1
A2
A3
A4
R5
R8
250 ft Spool-Pac
500 ft Spool-Pac
1000 ft Spool-Pac
2000 ft Spool-Pac
250 ft Spool, Retail
500 ft Spool, Retail
CSA FIRE ALARM COLOR CODE CHART
CONDUCTOR COLOR
CONDUCTOR COLOR
PAIR
COLOR
PAIR
COLOR
Black
Red
Green
Blue
Brown
Orange
Black w/White Stripe
Red w/White Stripe
Green w/White Stripe
Yellow w/White Stripe
Red w/Black Stripe
Green w/Black Stripe
Yellow w/Black Stripe
Green w/Red Stripe
Yellow w/Red Stripe
16th
17th
18th
19th
20th
21st
22nd
23rd
24th
25th
26th
27th
28th
29th
30th
White w/Brown Stripe
1st
2nd
3rd
4th
5th
6th
7th
8th
9th
10th
11th
12th
13th
14th
15th
Black & Red
16th
17th
18th
19th
20th
21st
22nd
23rd
24th
25th
26th
27th
White & Brown
White & Orange
Blue & Yellow
Blue & Brown
Blue & Orange
Brown & Yellow
Brown & Orange
Purple & Red
Purple & White
Purple & Blue
Purple & Brown
Purple & Yellow
1st
2nd
3rd
4th
5th
6th
7th
8th
9th
10th
11th
12th
13th
14th
15th
Green w/Brown Stripe
Yellow w/Brown Stripe
White w/Orange Stripe
Black w/Orange Stripe
Red w/Orange Stripe
Green w/Orange Stripe
Brown w/Orange Stripe
White w/Blue Stripe
Red w/Blue Stripe
Yellow w/Blue Stripe
Brown w/Blue Stripe
Black w/Red Stripe
White w/Red Stripe
Brown w/Red Stripe
Black & White
Black & Grey
Black & Blue
Black & Yellow
Black & Brown
Black & Orange
Black & Purple
Red & White
Red & Blue
Red & Yellow
Red & Brown
Red & Orange
White & Blue
White & Yellow
230
Technical Information
Electronics
Applications Index
Communication circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Communications . . . . . . . . . . . . . . . . . . 66, 114, 116-129, 159-160
Computer and computer interconnections . . . . . . . . 23-24, 26, 29,
31, 60, 68-69, 78
Computer interconnections . . . . . . . . . . . . . . . 24, 31, 60, 68-69, 78
Computer/networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Computers . . . . . . . . . . . . . . . . 29, 39, 43-44, 49-51, 53-54, 57-59,
62-64, 70-77, 79-84, 95, 112, 183-184
A
Access control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114, 131-133
Addressable Fire Alarm Systems . . . . . . . . . . . . . . . . . . . 125-128
Alliance Ham/CB and TV rotors compatibility . . . . . . . . . . . . . .139
Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152, 169
Analog video. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102, 115, 167
Analog/digital video . . . . . . . . . . . . . . . . . . . . . . . . . . . 99, 102, 115
Analog/digital video broadcast-grade monitors . . . . . . . . . . . . . 93
Annunciator systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143
Audio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25, 39, 134-137, 159
Audio components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166-168
Audio interconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-41
Audio systems . . . . . . . . . . . . . . . . . . . . . . 15-17, 25, 27-28, 45-46,
148, 156, 172, 175
Console board equipment . . . . . . . . . . . . . . . . . . . . . . . . . 166-168
Control circuits . . . . 9, 11-21, 24, 26-28, 31, 39-41, 43-45, 48-64,
68-84, 134-138, 152-153, 172, 175, 185
Cue line systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
D
Data and signal transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Data transmission . . . . . . . . . . . . . . . . 31, 43-44, 53-54, 60, 68-71,
73-77, 79, 95, 100, 112, 163
Audio/image/video products . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
Automatic valve control systems. . . . . . . . . . . . . . . . . . . . . . . . . .22
DBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86, 90-92, 115
Digital audio . . . . . . . . . . . . . . . . . . . . . . . . 147-148, 151, 157, 166
Digital audio interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
Digital data transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
Digital video cameras/displays/recorders . . . . . . . . . . . . . . . . . .183
Digital/audio . . . . . . . . . . . . . . . . . . . . . . . . 147-148, 151-157, 166
Direct broadcast satellite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Direct burial . . . . . . . . . . . . . 26, 89, 97-98, 104, 139-140, 164-165
Disc arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183-184
Door bells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143
Door control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132-133
Drop cable . . . . . . . . . . . . . . . . . . . . . . . . . . . 88, 91-92, 96-99, 103
B
Background music . . . . . . . . . . . . . . . . . . . .16-17, 27-28, 134-137
Basses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
Bell systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143
Bi-amp speakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152-153
Broadcast. . . . . . . . . . . . . . . . . . . . . . . . . . . . 94, 100, 107-108, 112
Broadcast and sound systems . . . . . . . . . . . . . . . . . . 23, 25, 29-30
Broadcast and studio. . . . . . . . . . . . . . . . . . . . . . . . . . 35, 38, 40-41
Broadcast and studio requirements. . . . . . . . . . . . . . . . . . . . . . . .21
Broadcast and studio use . . . . . . . . . . . . . . . . . . . . . . . . . .172, 175
Broadcast digital video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96-98
Broadcast grade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105-106
Broadcast-grade headend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Broadcast/HDTV . . . . . . . . . . . . . . . . . . . . . .88-93, 96-99, 107-108
Broadcast/Serial Digital Interface (SDI) . . . . . . . . . . . . . 92, 106-107
Broadcast-grade Serial Digital Interface (SDI) . . . . . . . . . . . . . . . .99
Burglar alarms . . . . . . . . . . . . . . . . . . . . . . .22, 32, 65-66, 116-121,
123, 129, 141-143
E
EIA RS-232 circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . 48, 52, 55-58
EIA RS-232 systems . . . . . . . . . . . . . . 11-14, 18-20, 30-31, 43-44,
54-56, 68-73, 75, 77-79
EIA RS-422 circuits . . . . . . . . . . . . . . . . . . . . . . . . 55-56, 77, 79, 83
EIA RS-423 systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72, 78
Effects pedals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
Electronic instrumentation control systems . . . . . . . . . . . . . . . . .47
EMI isolated circuits for instrumentation . . . . . . . . . . . . . . 159-160
Energy management systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Excellent shielding for noise reduction . . . . . . . . . . . . . . . . . . 34-38
External wiring of machinery . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Business machines . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 32, 65-66
C
Cable tray installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22, 32
CAD/CAM systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Card readers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114
Cash registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22, 32, 65
Cat 5e ScTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
Cat 5e UTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
CATV . . . . . . . . . . . . . . . . . . .86-92, 96-99, 101-106, 110-115, 150
CATV/headend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
CCTV . . . . . . . . . . . . . . . . . . . . . . . . 86-88, 90-92, 96-99, 101-102,
104-105, 110, 114-115, 162, 177
F
Fire alarm control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Fire alarm systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 122, 124-129
Fire protective circuits . . . . . . . . . . . . . . . . . . . . . . . . . 117-121, 123
FM broadcast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88, 91
G
Commercial broadcast facilities . . . . . . . . . . . . . . . . . . . . . . . . .158
Communication and audio system . . . . . . . . . . . . . . .148, 172, 175
Communication and control . . . . . . . . . . . . . . . . . . . . . . . . . . .161
General-purpose audio applications . . . . . . . . . . . . . . . . . . . . . .170
Good flexibility . . . . . . . 23, 29-31, 34, 36-37, 53-54, 70-72, 75-79
Guitars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
231
Electronics
Technical Information
Applications Index
Low signal distortion data requirements . . . . . . . . . . . . . . . . . . . .78
Low-voltage installations . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143
Low-voltage power distribution, electronic
and data processing equipment . . . . . . . . . . . . . . . . . . . . . . .182
Low-impedance microphones . . . . . . . . . . . . . . . . . . 172, 174-175
Low-voltage golf course satellite sprinkler control . . . . . . . . . . .140
H
HDTV . . . . . . . . . . . . . . . . . . . . . . . . . . 86-93, 96-99, 107-108, 115
Heating and air conditioning installations . . . . . . . . . . . . . . 141-143
Helical binding or overall jacketing . . . . . . . . . . . . . . . . . . . . . . .163
Hi-fi and stereo speaker wire . . . . . . . . . . . . . . . . . . . . . . . 156-157
High speed computer interconnects . . . . . . . . . . . . . . . . . . . . . . .78
High speed computers . . . . . . . . . . . . . . . . . . . . . . . . . . . 72, 83-84
High speed solid state circuits for
M
MATV . . . . . . . . . . . . . . . . . . . 86, 88-89, 96-99, 101-106, 110, 115
Mixers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
Monitor applications . . . . . . . . . . . . . . . . . . . . . . . . . . . 93, 107-108
Monitor systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
Monitor/VDT display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101-104
Motor and transformer lead . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Multiple cable pulls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
Musical instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170
low-voltage applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182
High-end microphones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
High-impedance microphones . . . . . . . . . . . . . . . . . . . . . .172, 175
Home entertainment . . . . . . . . . . . . . . . . . . 147-148, 151-156, 170
Home theater . . . . . . . . . . . . . . . 114, 116, 147-148, 151-153, 156
I
Industrial control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Industrial equipment . . . . . . . . . . . . . . .43-44, 53-54, 58-59, 70-84
Industrial equipment control . . . . . . . . . . . . . . 23, 29-31, 60, 68-69
IEEE 802.3 and ISO/IEC 8802.3
N
Noise reduction shielding . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-38
Non QPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4, 37
Not for in-wall use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156-158
10 Base 5 LAN computer cables . . . . . . . . . . . . . . . . . . . . . . . .95
IEEE 802.3 and ISO/IEC 8802.3
O
10 Base 2 computer cables . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
Instrumentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150, 159-161
Instrumentation and control use . . . . . . . . . . . . . . . . . . . . . . . . . .46
Instrumentation systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25, 47
Intercom systems . . . . . . . . . . . . . . . . . . .16-17, 22, 27-28, 32, 47,
65-66, 138, 141-143
Optical fiber cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
Oscillators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Outdoor installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Outdoor rated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138-140, 176
Outdoor signal processing gear . . . . . . . . . . . . . . . . . . . . . . . . .169
Outdoor use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164-165
Intercoms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9, 11-14, 18-20, 116
Interconnection components . . . . . . . . . . . . . . . . . . . . . . . 166-168
Internal telephones . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-14, 18-20
Internal wiring, electrical/electronic equipment,
panels/meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
In-wall speakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147, 151-155
Irrigation systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
P
Parallel or serial transmission . . . . . . . . . . . . . . . . . . . . . . . . . . .184
Personal computers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183-184
Petrochemical control systems . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Petrochemical refineries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Plenum versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
Point-of-sale systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Point-to-point wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Power-limited circuits . . . . . . . . . . . . . . . . . . . . . . . . . 22, 32, 65-66
Power-limited control circuits . . . . . . . . . . . . . . . .16-17, 27-28, 48,
52, 55, 61, 134-137
J
Jukeboxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156-157
K
Keyboards and other instruments to amplifiers,
Precision video – analog/digital . . . . . . . . . . . . . . . . . . . . . 105-106
Primary power distribution, electronic
and data processing equipment . . . . . . . . . . . . . . . . . . . . . . .182
Process control and instrumentation . . . . . . . . . . . . 15, 26, 39, 45,
48-52, 55-57, 61-64
Programmable Logic Controllers (PLC) . . . . . . . . . . . . . . . . . . .112
Public address systems . . . . . . . . . . . . . . . . . . . . . . . . 9-14, 18-20
Pull boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122, 124-128
mixers, and effects pedals . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
L
LAN and data transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
LAN and data transmission computer cables . . . . . . . . . . . . . . .95
LAN cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Line level microphone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167-168
Line level signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167-168
Local area network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101-104
Low capacitance applications . . . . 35, 38, 72, 74, 83-84, 166-169
Low capacitance requirements . . . . . . . . . . . . . . . . . . 56, 76-77, 79
Low cost alternative to laminated bus bars . . . . . . . . . . . . . . . .182
Low inductance DC applications . . . . . . . . . . . . . . . . . . . . . . . .182
R
Radio station components, interconnection and audio . . . 166-168
Radio transmitters . . . . . . . . . . . . . . . . . . . . . . . 33-34, 36, 171, 173
Radios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-34, 36, 171, 173
232
Technical Information
Electronics
Applications Index
Recording studios . . . . . . . . . . . 33-34, 36, 158, 166-168, 171, 173
Recording studios and sound stages . . . . . . . . . . . . . . . . 23, 29-30
Recording studio components,
interconnection and audio . . . . . . . . . . . . . . . . . . . . . . . . 166-168
Remote control circuits . . . . . . . . . . . . .9, 11-15, 18-20, 26, 39, 45,
48-52, 55-57, 61-64, 138, 152-153
Speaker extension service . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138
Special audio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159-161
Stereo systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148, 151-155
Studio use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148, 172, 175
Suggested voltage rating: 1000 volts . . . . . . . . . . . . . . . . . . . .174
Suggested voltage rating: 1000 volts (MIL-W 76B) . . . . . . . . . . . .4
Suggested voltage rating: 150 volts . . . . . . 16-17, 27-28, 52, 138
Suggested voltage rating: 200 volts . . . . . . . . . . . . . . . . . . . . .139
Suggested voltage rating: 30 volts . . . . . . . . . . . 72, 74, 76-79, 82
Suggested voltage rating: 300 or 600 volts . . . . . . . . . . 18-20, 23,
29-31, 53-54, 59
Remote control for studio equipment . . . . . . . . . . . . . . . . . . . . . .37
Remote control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
Remote control units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143
Residential sprinkler solenoid control . . . . . . . . . . . . . . . . . . . . .140
REX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132-133
RF shielding . . . . . . . . . . . . . . . . . . . . . . . 24, 33-38, 164, 171, 173
RF signal transmission . . . . . . . . . . . . . . . . . . . . 88, 91, 94, 96-111
RG6 video/data quad shield coax . . . . . . . . . . . . . . . . . . . . . . .163
RGB video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115, 162
Riser versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
Rotor antenna controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
RS-232 circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48, 52, 55-56
RS-232 systems . . . . . . . . . . . . . . . . . 11-14, 18-20, 30-31, 43-44,
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53-54, 68-73, 75, 77-79
RS-422 circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55-56
RS-423 systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72, 78
Suggested voltage rating: 300 volts . . . 2, 9-15, 22, 24-26, 32-36,
38-41, 43-51, 55-58, 60-66, 68-71, 73,
75, 80-81, 83-84, 117-129, 134-138,
148, 154, 159, 161, 171-173, 175, 185
Suggested voltage rating: 350 volts . . . . . . . . . . . . . . 21, 164-165
Suggested voltage rating: 600 volts . . . . . . . . . . . . . . . . . . . .3, 37
Suitable for EIA RS-232 and RS-423
CAD/CAM applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Suitable for EIA RS-232 applications . . . . . . . 11-14, 18-20, 30-31,
43-44, 53-54, 68-73, 75, 77-79
Suitable for EIA RS-422 applications
77, 79
Suitable for EIA RS-422 CAD/CAM applications . . . . . . . . . . . . .83
Suitable for EIA RS-485 applications . . . . . . . . . . . . . . . . . . . . . .76
S
Satellite actuator control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101
Satellite receivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
Secondary power distribution, electronic
T
Television station components,
and data processing equipment . . . . . . . . . . . . . . . . . . . . . . .182
Security systems . . . . . . . . . . . . . . . . . . . . . . . . . 132-133, 152-153
Serial Digital Interface (SDI) . . . . . . . . . . . . . . . . . . .87, 92, 99, 107
Shielded cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24, 164
Shielded power supplies . . . . . . . . . . . . . . . . . . . . . . .148, 172, 175
Shielding, Fire Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183-184
Shielding, noise reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-38
Shielding, SCSi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
Shielding, USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
Signal isolation, total . . . . . . . . . . . . . . . . . . . . . . . . . . 61-64, 80-84
Signal systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143
Smoke detectors . . . . . . . . . . . . . . . . . . . . . . . . . 115, 117, 121-128
Sound system installations . . . . . . . . . . . . . . . . . . . . . . . . . 166-168
Sound systems . . . . . . . . . . . . . . . . . . . . . . . .23, 25, 29-30, 33-38,
47, 116, 171, 173
interconnection and audio . . . . . . . . . . . . . . . . . . . . . . . 166-168
Test equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Thermostat control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143
Thicknet/trunk cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
Touch-plate systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143
Tray cable installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65-66
TV broadcast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
TV cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
V
Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88-93, 96-98
Video and audio interconnecting cables . . . . . . . . . . . . . . .172, 175
Video interconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38, 38
Video – analog/digital . . . . . . . . . . . . . . . . . . . . . . 99, 102, 105-108
Voice communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117-129
233
Electronics
Technical Information
Belden-to-General Cable Carol® Brand Cross Reference Index
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
1030A
1031A
1032A
1186A
1189A
1189AP
1190A
1242A
1266A
1306SB
1307A
1309A
1426A
1502A
1502P
1503A
1505A
1506A
1508A
1513A
1523A
1523AP
1525A
1530A
1583A
1585A
1617A
1694A
1694SB
1695A
1841A
1855A
1861A
1883A
1884A
1912A
19352
3105A
3107A
3108A
5000FE
5000UE
5002UE
5020FL
5020UL
5100FE
5100UE
5102A
5102UE
5102UP
5120FJ
5120FL
5120LL
5120UL
C0456A
C0457A
C0454A
C5784
C5785
C3525
C5804
E1001S
E2022S
C8029
C1804
C1802
C1142
495023
C8125
C0600A
395025
495023
C2513A
C5776
C5039
C3528
C5039
C5776
CR5
32
32
32
103
89
91
5122FL
5122UL
513945
5200FE
5200UE
5200UP
5201FE
5201UE
5202FE
5202UE
5220FL
5220LL
5220UL
5222FL
5222UL
5300FE
5300UE
5301FE
5301UE
5302FE
5302UE
5304FE
5304UE
5306FE
5306UE
5308UE
5309UE
5300UE
5320FE
5320FL
5320LL
5320UE
5320UL
5321FL
5321UL
5322FL
5322UL
5324UL
5341A
E2534S
E1524S
395058
E2042S
E1042S
C1804
119
117
99
135
134
153
23
89
C2537A
E1043S
E2244S
E1044S
E2522S
E2404S
E1512S
E2524S
E1514S
E2032S
E1032S
E2033S
E1033S
E2034S
E1034S
E2036S
E1036S
E2038S
E1038S
E1040S
E1041S
E1032S
E2030S
E2502S
E2402S
E1030S
E1502S
E2503S
E1503S
E2504S
E1504S
E1506S
C0560A
C6103A
E2022S
C6351A
E2023S
E1023S
E2024S
E1024S
E1022S
C1142
134
135
91
153
153
101
106
185
73
106
106
23
88
97
97
97
88
N/A
N/A
97
92
90
134
137
134
119
135
117
119
117
135
134
135
134
135
134
135
134
135
134
134
134
134
135
119
117
134
117
119
117
119
117
117
66
CP5
C5044
395011
C5814
495025
C5822
395031
C1004A
C0600A
C5889
740512
86013
C7112A
C7114A
C7116A
E2062S
E1062S
E1064S
E2542S
E1532S
E2052S
E1052S
E1054S
E1054S
C1803
C0475
E2532S
E2406S
E1522S
92
90
107
154
73
89
167
N/A
66
66
66
5342UE
5400FE
5400UE
5401FE
5401UE
5402FE
5402UE
540OUE
543945
549945
5500FE
5500UE
5501FE
5501UE
5502FE
44
135
13
135
134
134
119
117
135
134
134
134
153
126
119
117
117
135
134
135
134
134
101
104
135
134
135
134
135
C8028
E2002S
E1002S
E2003S
E1003S
E2004S
This cross reference guide should be used in conjunction with the product information in our
catalog or on our website. It should be used for suggested alternative items which are functionally
equal. Constructional differences are not indicated. General Cable is not responsible for variances
due to competitor and industry constructional changes or agency updates.
234
Technical Information
Electronics
Belden-to-General Cable Carol® Brand Cross Reference Index
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
5502UE
5504FE
5504UE
5506FE
5506UE
5508FE
5508UE
5509FE
5509UE
550OUE
5520FE
5520UE
5522UE
5522UL
5545UE
5562FE
558AFS
558GMS
6000UC
6000UE
6020FL
6020UL
6100FE
6100UE
6100UF
6102UE
6120FL
6120UL
6122FL
6122UL
6200FE
6200UE
6201FE
6201UE
6202FE
6202UE
6220FL
6220UL
6222FL
6222UL
6300FE
6300UE
6301FE
6301UE
6302FE
6302UE
6304FE
6304UE
6306FE
6306UE
6320FE
6320FL
6320UE
6320UL
E1004S
E2006S
E1006S
E2008S
E1008S
E2010S
E1010S
E2012S
E1012S
E1002S
E2000S
E1000S
E1001S
E1484S
C6106A
C0722A
4ERS4S
4ERS1S
C3129
134
135
134
135
134
135
134
135
134
134
135
134
134
117
44
6321FL
6321UL
6322FL
6322UL
6324UL
633948
6400FE
6400UE
6401FE
6401UE
6402FE
6402UE
643948
649948
6500FE
6500UE
6501FE
6501UE
6502FE
6502UE
6504FE
6504UE
6506FE
6506UE
6520FE
6520UE
6522UE
6541FE
6543A
6545FE
658AFS
658GMS
7731A
7732A
7987P
7987R
7989P
7989R
8102
E3603S
E3503S
E3604S
E3504S
E3506S
495035
E2122S
E3022S
E2123S
E3023S
E2124S
E3024S
495028
C8030
E2102S
E3002S
E2103S
E3003S
E2104S
E3004S
E2106S
E3006S
E2108S
E3008S
E2100S
E3000S
E3001S
C3205
123
121
123
121
121
92
137
136
137
136
137
136
105
101
137
136
137
136
137
136
137
136
137
136
137
136
136
48
73
133
133
17
136
123
121
137
136
17
136
128
121
123
121
27
E3062S
E3632S
E3532S
E2252S
E3052S
C3128
E3054S
C3174
E3522S
E3624S
E3524S
E2242S
E3042S
E2243S
E3043S
C3341
E3044S
E3612S
E3512S
E3614S
E3514S
E2202S
E3032S
E2203S
C3120
E2204S
C3113
E2206S
C3121
E2208S
C3122
E2200S
E3602S
E3030S
E3502S
C3151
C3208
48
48
132
132
99
4EPL4S
4EPL1S
395029
495027
E3842S
E1842S
E3843S
E1843S
C0515A
C0516A
C0517A
C0518A
C0519A
C0520A
C0521A
C0522A
C0523A
C0524A
C0525A
C0526A
C0924A
C0925A
C0926A
C6351A
17
137
136
27
99
162
162
162
162
78
78
78
78
78
78
78
78
78
78
78
78
84
136
123
121
123
121
137
136
137
17
137
17
137
17
137
17
137
123
136
121
8103
8104
8105
8106
8107
8108
8110
8112
8115
8118
8125
8162
8163
8164
8205
84
84
13
This cross reference guide should be used in conjunction with the product information in our
catalog or on our website. It should be used for suggested alternative items which are functionally
equal. Constructional differences are not indicated. General Cable is not responsible for variances
due to competitor and industry constructional changes or agency updates.
235
Electronics
Technical Information
Belden-to-General Cable Carol® Brand Cross Reference Index
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
8212
8213
8214
8216
8218
8219
8221
82241
82248
82262
8228
8237
8240
82442
8248
82489
82503
8259
8261
8262
8263
82641
8267
82723
82729
82740
82760
82761
82777
82778
82842
8302
8303
8304
8305
8306
8307
8308
8310
8312
83206
8325
8332
8333
8334
8335
8336
8337
8340
8342
83503
83653
83654
83656
C1102
C5025
C1198
C1156
C1158
C1188
C1135
C3500
C3523
C3520
C5760
C1154
C1166
E3002S
C3521
C8102
C8113
C1178
C1160
C1155
C1106
C8127
C1176A
C8105
C8134
C8122
C8123
C8126
C8131
C8133
C8129
C0650A
C0651A
C0652A
C0653A
C0654A
C0655A
C0656A
C0658A
C0660A
C8101
C0663A
C0620A
C0621A
C0622A
C0623A
C0624A
C0625A
C0628A
C0630A
C8115
C8107
C8110
C8120
101
96
94
110
105
100
101
104
91
109
88
94
100
136
91
83702
83703
83706
8412
8418
8422
8423
8424
8425
8426
8427
8428
8437
8441
8442
8443
8444
8445
8446
8447
8448
8449
8450
8451
8456
8457
8458
8459
8460
8461
8465
8466
8467
8468
8469
8471
8473
8477
8486
8488
8489
8520
8521
8522
8523
8524
8525
8527
8612
8618
8619
8620
8621
8622
C8111
C8119
C8108
C1302
C1313
C1322A
C1304
C1305
C1308
C1310
39
39
39
40, 172
40
174
40
40
40
40
40
41, 175
34
34
12
12
12
12
10
10
10
10
23
23
12
12
12
12
156
13
13
13
13
13
13
14
14
14
9
C1312
C1202
C2676A
C2677A
C6348A
C4062A
C4063A
C4064A
C4081A
C4082A
C4083A
C4084A
C2515A
C2516A
C4071A
C4067A
C4073A
C4076A
C7102A
C2830A
C2420A
C2412A
C2421A
C2423A
C2422A
C2405A
C2409A
C2410A
C2754A
C1130
C2404A
C7610A
C7608A
C7606A
C7604A
C7602A
C7600A
C7611A
C3521
C2537A
C2424A
C2425A
C2426A
C2427A
15
51
100
96
100
101
51
111
62
62
45
51
51
62
62
57
75
75
75
75
75
75
75
75
75
49
75
75
75
75
75
75
75
75
75
39
39
39
139
13
4
4
4
4
4
4
66
91
23
13
14
14
14
39
This cross reference guide should be used in conjunction with the product information in our
catalog or on our website. It should be used for suggested alternative items which are functionally
equal. Constructional differences are not indicated. General Cable is not responsible for variances
due to competitor and industry constructional changes or agency updates.
236
Technical Information
Electronics
Belden-to-General Cable Carol® Brand Cross Reference Index
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
8623
8624
8627
8628
8641
8649
8661
8690
8691
8692
8718
8719
8720
8722
8723
8723SB
8724
8725
8728
8729
8732
8735
8737
8740
8741
8742
8743
8747
8748
8749
8751
8757
8759
8760
8761
8762
8763
8767
8768
8769
8770
8771
8772
8773
8774
8775
8776
87760
87761
8777
8777SB
8778
8780
8782
C2428A
C2429A
C2430A
C2431A
C2513A
C1360
14
14
14
14
23
156
14
44
44
44
23
23
23
160
58
N/A
160
80
8786
8790
8791
8795
88102
88723
88760
88761
88770
8898
8899
8916
8917
8918
8919
8920
89418
88778
89729
89740
89841
9011
9066
9116
9116P
9116R
9116SB
9117
9151
9151SB
9154
9155
9156
9157
9159
9161
9182
9201
9207
9209
9248
9258
9259
9265
9269
9291
9302
9305
9306
9309
9312
9314
9315
9316
C1345A
C2892A
C2768A
C4408
C8118
C8112
C8101
C8109
C8106
C1318
159
33
33
138
50
63
49
49
26
7
7
3
3
3
3
3
26
63
64
45
57
96
89
88
91
88
N/A
89
154
24
135
160
44
44
44
44
112
100
112
107
91
94
101
102
109
103
46
46
46
46
32
32
46
32
C2426A
C6103A
C6106A
C6109A
C2539A
C2536A
C2538A
C1331A
C1352A
C1352ACS
C1340A
C1368A
C1353A
C7110A
C1338A
C2678A
C2882A
C4008A
C4010A
C4014A
C4017A
C6017A
C6019A
C6026A
C6451A
C4015A
C2888A
C2534A
C2514A
C2524A
C1333A
C6035A
C6036A
C6045A
C2535A
C2526A
C2525A
C6046A
C6042A
C6043A
C6044A
C8104
C1321
C2105A
C2104A
C2103A
C2102A
C2101A
C8114
C8132
C8128
C8116
C8117
C5034
C5804
C5775
C3524
C5886
C5775ACS
C5802
C1000A
C2520
E2022S
C1343A
C6118A
C6119A
C6120A
C6121A
C8014
C1117
C8000
395031
C5778
C1108A
C1103
58
N/A
161
36
33
9, 43
43
43
43
43
43
43
47
43
33
23
23
23
159
81
81
82
23
23
23
82
82
82
82
49
49
82
N/A
82
33
C8025
C1164
C5770
C1670A
C1676A
C1671A
C1672A
C0460A
C0458A
C1673A
C0456A
C8103
C6040A
C6040ACS
C6041A
C2895A
C1356
156
This cross reference guide should be used in conjunction with the product information in our
catalog or on our website. It should be used for suggested alternative items which are functionally
equal. Constructional differences are not indicated. General Cable is not responsible for variances
due to competitor and industry constructional changes or agency updates.
237
Electronics
Technical Information
Belden-to-General Cable Carol® Brand Cross Reference Index
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
9318
9320
9322
9328
9329
9330
9331
9332
9333
9363
9364
9365
9366
9367
9368
9369
9388
9389
9390
9391
9392
9397
9402
9406
9407
9408
9409
9410
9411
9412
9414
9418
9421
9423
9430
9431
9432
9433
9434
9438
9439
9444
9445
9451
9451P
9451SB
9452
9455
9457
9458
9460
9461
9462
9464
C0454A
C0452A
C0450A
C0570A
C0571A
C0572A
C0573A
C0574A
C0575A
C0451A
C0453A
C0455A
C0457A
C0459A
C0584A
C0585A
C0586A
C0587A
C0588A
C0589A
C0590A
C1226A
C7106A
C1350A
C0431A
C0433A
C0435A
C0437A
C0439A
C0441A
C6010A
C2543A
C4065A
C4070A
C4088A
C4075A
C4077A
C4078A
C4079A
C7108A
C6356A
C6353A
C6355A
C2520A
C8124
32
32
32
65
65
65
65
65
65
32
32
32
32
32
65
65
65
65
65
65
65
173
58
60
22
22
22
22
22
22
43
25
12
12
12
12
12
12
12
7
9491
9492
9493
9494
9495
9501
9502
9503
9504
9505
9506
9507
9508
9509
9510
9512
9513
9514
9515
9516
9519
9520
9521
9524
9525
9533
9534
9535
9536
9537
9538
9539
9540
9541
9542
9543
9544
9545
9546
9552
9553
9554
9556
9559
9565
9608
9609
9610
9611
9612
9613
9614
9615
9616
C0432A
C0434A
C0436A
C0438A
C0440A
C0600A
C0601A
C0602A
C0603A
C0604A
C0605A
C0606A
C0607A
C0608A
C0609A
C0550A
C0551A
C0552A
C0610A
C0553A
C0611A
C0554A
C0555A
C0556A
C0612A
C0741A
C0742A
C0753A
C0743A
C0754A
C0744A
C0755A
C0745A
C0746A
C0747A
C0748A
C0749A
C0750A
C0751A
C0560A
C0561A
C0562A
C0563A
C0564A
C0566A
C0951A
C0952A
C0953A
C0954A
C0955A
C0956A
C0957A
C0958A
C0959A
22
22
22
22
22
73
73
73
73
73
73
73
73
73
73
66
66
66
73
66
73
66
66
66
73
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
66
66
66
66
70
70
70
70
70
70
70
70
70
13
13
13
24
51
24
171
13
13
13
24
24
46
24
C2520A
C1228A
C6357A
C6360A
C6358A
C2521A
C2518A
C7104A
C2519A
This cross reference guide should be used in conjunction with the product information in our
catalog or on our website. It should be used for suggested alternative items which are functionally
equal. Constructional differences are not indicated. General Cable is not responsible for variances
due to competitor and industry constructional changes or agency updates.
238
Technical Information
Electronics
Belden-to-General Cable Carol® Brand Cross Reference Index
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
BELDEN
PART NUMBER
GENERAL CABLE/
CAROL PART NUMBER
PAGE
NUMBER
9617
9620
9621
9622
9623
9626
9637
9708
9712
9716
9717
9718
9721
9728
9729
9730
9731
9732
9733
9734
9735
9740
9742
9744
9745
9746
9747
9768
9769
9770
9773
9774
9775
9776
9777
9791
9794
9802
9803
9804
9805
9806
9807
9808
9809
9812
9829
9830
9831
9832
9833
9835
9836
9839
C0961A
C2434A
C2435A
C2436A
C2437A
C2433A
C0948A
C1357
C1362
C1358
C1361
C1363
70
14
14
14
14
13
70
156
156
156
156
156
14
83
83
83
83
83
83
83
83
44
44
43
43
43
43
82
82
23
82
82
82
82
82
72
134
164
164
79
79
79
79
79
79
79
77
77
77
77
77
77
77
77
9841
9842
9843
9844
9862
9863
9873
9874
9875
9877
9879
9883
9886
9890
9899
9910
9912
9913
9916
9918
9919
9921
9923
9924
9925
9927
9929
9931
9932
9933
9934
9935
9936
9939
9940
9941
9942
9943
9944
9945
9946
9947
9948
9990
9991
9992
C4841A
C4842A
C4843A
C4844A
C1162
76
76
76
76
109
112
82
82
82
82
82
165
165
164
7
3
3
94
2
2
2
2
2
3
72
72
72
72
72
72
72
72
72
71
71
71
71
71
71
71
71
71
71
82
82
82
C8000
C6052A
C6053A
C6054A
C6056A
C6058A
C6061A
C6062A
C2511A
C1320A
C2107A
C2106A
C1180
C2065A
C2064A
C2040A
C2016A
C2015A
C2100A
C0680A
C0681A
C0682A
C0683A
C0684A
C0685A
C0686A
C0687A
C0688A
C0971A
C0972A
C0973A
C0974A
C0975A
C0976A
C0977A
C0978A
C0979A
C0981A
C6065A
C6066A
C6067A
C2443A
C0912A
C0910A
C0911A
C0913A
C0914A
C0915A
C0916A
C0917A
C6101A
C6111A
C6010A
C6014A
C6015A
C6023A
C6059A
C6060A
C2517A
C6047A
C6048A
C6049A
C6050A
C6051A
C0533A
E1004S
C2509A
C2510A
C0804A
C0805A
C0806A
C0807A
C0808A
C0809A
C0812A
C0829A
C0830A
C0831A
C0832A
C0833A
C0835A
C0836A
C0839A
This cross reference guide should be used in conjunction with the product information in our
catalog or on our website. It should be used for suggested alternative items which are functionally
equal. Constructional differences are not indicated. General Cable is not responsible for variances
due to competitor and industry constructional changes or agency updates.
239
Electronics
Technical Information
Part Number Index
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
page
page
page
page
4EPL1S ................................. 132
4EPL4S ................................. 132
4ERS1S ................................ 133
4ERS4S ................................ 133
05091 ................................... 141
05092 ................................... 141
05093 ................................... 141
05094 ................................... 141
05095 ................................... 141
05096 ................................... 141
05097 ................................... 141
05098 ................................... 141
05099 ................................... 141
05481 ................................... 142
05482 ................................... 142
05483 ................................... 142
05484 ................................... 142
05485 ................................... 142
05486 ................................... 142
05487 ................................... 142
05488 ................................... 142
05489 ................................... 142
05581 ................................... 142
05582 ................................... 142
05583 ................................... 142
05584 ................................... 142
05585 ................................... 142
05586 ................................... 142
05587 ................................... 142
05588 ................................... 142
05589 ................................... 142
05782 ................................... 143
05783 ................................... 143
05784 ................................... 143
05785 ................................... 143
05786 ................................... 143
05788 ................................... 143
23804-18-01 ........................ 140
23805-18-01 ........................ 140
23807-18-01 ........................ 140
23810-18-01 ........................ 140
23815-60-01 ........................ 140
23817-60-01 ........................ 140
23824-60-01 ........................ 140
23825-60-01 ........................ 140
23827-60-01 ........................ 140
76502 ....................................... 5
76512 ....................................... 5
76812 ....................................... 5
76822 ....................................... 5
76832 ....................................... 5
76843 ....................................... 5
76954 ....................................... 6
76994 ....................................... 6
395011 ................................... 92
395011-3 ............................... 93
395011-4 ............................... 93
395011-5 ............................... 93
395025 ................................. 106
395025-3 ............................. 107
395025-4 ............................. 107
395025-5 ............................. 107
395025-10 ........................... 107
395027 ................................. 110
395029 ................................... 99
395031-3 ............................. 107
395031-5 ............................. 107
395035-3 ............................. 108
395035-4 ............................. 108
395035-5 ............................. 108
395058 ................................... 99
397001 ................................... 95
495015 ................................... 99
495016 ................................... 99
495023 ................................. 106
495025 ................................... 92
495027 ................................... 99
495028 ................................. 105
495035 ................................... 92
495036 ................................... 92
497001 ................................... 95
574608 ................................. 176
710010 ................................. 163
710011 ................................. 163
710017 ................................. 163
710018 ................................. 163
710021 ................................. 163
710022 ................................. 163
710023 ................................. 163
710024 ................................. 163
740002 ................................. 158
740004 ................................. 158
740102 ................................. 158
740104 ................................. 158
740202 ................................. 158
740204 ................................. 158
740302 ................................. 158
740304 ................................. 158
C0438A .................................. 22
C0439A .................................. 22
C0440A .................................. 22
C0441A .................................. 22
C0444A .................................. 22
C0450A .................................. 32
C0451A .................................. 32
C0452A .................................. 32
C0453A .................................. 32
C0454A .................................. 32
C0455A .................................. 32
C0456A .................................. 32
C0457A .................................. 32
C0458A .................................. 32
C0459A .................................. 32
C0460A .................................. 32
C0471 .................................. 125
C0472 .................................. 126
C0473 .................................. 125
C0474 .................................. 126
C0475 .................................. 126
C0476 .................................. 126
C0485 .................................. 125
C0486 .................................. 125
C0491 .................................. 125
C0492 .................................. 125
C0494 .................................. 126
C0495 .................................. 126
C0496 .................................. 126
C0497 .................................. 126
C0515A .................................. 78
C0516A .................................. 78
C0517A .................................. 78
C0518A .................................. 78
C0519A .................................. 78
C0520A .................................. 78
C0521A .................................. 78
C0522A .................................. 78
C0523A .................................. 78
C0524A .................................. 78
C0525A .................................. 78
C0526A .................................. 78
C0530A .................................. 72
C0531A .................................. 72
C0532A .................................. 72
C0533A .................................. 72
C0534A .................................. 72
C0535A .................................. 72
C0536A .................................. 72
740501 ................................. 167
740504 ................................. 167
740508 ................................. 167
740512 ................................. 167
740516 ................................. 167
740520 ................................. 167
740528 ................................. 167
740542 ................................. 167
740552 ................................. 167
740601 ................................. 166
740604 ................................. 166
740608 ................................. 166
740612 ................................. 166
740616 ................................. 166
740620 ................................. 166
740701 ................................. 168
740704 ................................. 168
740706 ................................. 168
740708 ................................. 168
740709 ................................. 168
740712 ................................. 168
740716 ................................. 168
740720 ................................. 168
740728 ................................. 168
740742 ................................. 168
740752 ................................. 168
742605 ................................. 177
742608 ................................. 176
743601 ................................. 169
743602 ................................. 169
743603 ................................. 169
743604 ................................. 169
743605 ................................. 169
743701 ................................. 170
743704 ................................. 170
743705 ................................. 170
743706 ................................. 170
743707 ................................. 170
810021 ................................. 163
810022 ................................. 163
810023 ................................. 163
810024 ................................. 163
C0431A .................................. 22
C0432A .................................. 22
C0433A .................................. 22
C0434A .................................. 22
C0435A .................................. 22
C0436A .................................. 22
C0437A .................................. 22
240
Technical Information
Electronics
Part Number Index
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
page
page
page
page
C0537A .................................. 72
C0538A .................................. 72
C0550A .................................. 66
C0551A .................................. 66
C0552A .................................. 66
C0553A .................................. 66
C0554A .................................. 66
C0555A .................................. 66
C0556A .................................. 66
C0560A .................................. 66
C0561A .................................. 66
C0562A .................................. 66
C0563A .................................. 66
C0564A .................................. 66
C0566A .................................. 66
C0570A .................................. 65
C0571A .................................. 65
C0572A .................................. 65
C0573A .................................. 65
C0574A .................................. 65
C0575A .................................. 65
C0584A .................................. 65
C0585A .................................. 65
C0586A .................................. 65
C0587A .................................. 65
C0588A .................................. 65
C0589A .................................. 65
C0590A .................................. 65
C0600A .................................. 73
C0601A .................................. 73
C0602A .................................. 73
C0603A .................................. 73
C0604A .................................. 73
C0605A .................................. 73
C0606A .................................. 73
C0607A .................................. 73
C0608A .................................. 73
C0609A .................................. 73
C0610A .................................. 73
C0611A .................................. 73
C0612A .................................. 73
C0620A .................................. 75
C0621A .................................. 75
C0622A .................................. 75
C0623A .................................. 75
C0624A .................................. 75
C0625A .................................. 75
C0626A .................................. 75
C0628A .................................. 75
C0630A .................................. 75
C0650A .................................. 75
C0651A .................................. 75
C0652A .................................. 75
C0653A .................................. 75
C0654A .................................. 75
C0655A .................................. 75
C0656A .................................. 75
C0658A .................................. 75
C0660A .................................. 75
C0663A .................................. 75
C0680A .................................. 72
C0681A .................................. 72
C0682A .................................. 72
C0683A .................................. 72
C0684A .................................. 72
C0685A .................................. 72
C0686A .................................. 72
C0687A .................................. 72
C0688A .................................. 72
C0720A .................................. 73
C0721A .................................. 73
C0722A .................................. 73
C0723A .................................. 73
C0724A .................................. 73
C0725A .................................. 73
C0726A .................................. 73
C0728A .................................. 73
C0729A .................................. 73
C0730A .................................. 73
C0740A .................................. 68
C0741A .................................. 68
C0742A .................................. 68
C0743A .................................. 68
C0744A .................................. 68
C0745A .................................. 68
C0746A .................................. 68
C0747A .................................. 68
C0748A .................................. 68
C0749A .................................. 68
C0750A .................................. 68
C0751A .................................. 68
C0753A .................................. 68
C0754A .................................. 68
C0755A .................................. 68
C0760A .................................. 69
C0761A .................................. 69
C0762A .................................. 69
C0763A .................................. 69
C0924A .................................. 84
C0925A .................................. 84
C0926A .................................. 84
C0939A .................................. 70
C0940A .................................. 70
C0941A .................................. 70
C0942A .................................. 70
C0943A .................................. 70
C0944A .................................. 70
C0945A .................................. 70
C0946A .................................. 70
C0947A .................................. 70
C0948A .................................. 70
C0951A .................................. 70
C0952A .................................. 70
C0953A .................................. 70
C0954A .................................. 70
C0955A .................................. 70
C0956A .................................. 70
C0957A .................................. 70
C0958A .................................. 70
C0959A .................................. 70
C0960A .................................. 70
C0961A .................................. 70
C0971A .................................. 71
C0972A .................................. 71
C0973A .................................. 71
C0974A .................................. 71
C0975A .................................. 71
C0976A .................................. 71
C0977A .................................. 71
C0978A .................................. 71
C0979A .................................. 71
C0980A .................................. 71
C0981A .................................. 71
C1000A ................................ 154
C1001A ................................ 154
C1002A ................................ 154
C1003A ................................ 154
C1004A ................................ 154
C1005A ................................ 154
C1102 .................................. 101
C1103 .................................. 101
C1104 .................................. 101
C1106 .................................. 101
C1108A .................................. 94
C1110 .................................. 102
C1112 .................................. 102
C1117 .................................. 100
C0764A .................................. 69
C0765A .................................. 69
C0766A .................................. 69
C0767A .................................. 69
C0768A .................................. 69
C0780A .................................. 69
C0781A .................................. 69
C0782A .................................. 69
C0783A .................................. 69
C0784A .................................. 69
C0785A .................................. 69
C0786A .................................. 69
C0787A .................................. 69
C0788A .................................. 69
C0804A .................................. 79
C0805A .................................. 79
C0806A .................................. 79
C0807A .................................. 79
C0808A .................................. 79
C0809A .................................. 79
C0810A .................................. 79
C0812A .................................. 79
C0829A .................................. 77
C0830A .................................. 77
C0831A .................................. 77
C0832A .................................. 77
C0833A .................................. 77
C0835A .................................. 77
C0836A .................................. 77
C0839A .................................. 77
C0841A .................................. 76
C0842A .................................. 76
C0843A .................................. 76
C0844A .................................. 76
C0890A .................................. 74
C0893A .................................. 74
C0894A .................................. 74
C0896A .................................. 74
C0897A .................................. 74
C0899A .................................. 74
C0901A .................................. 74
C0910A .................................. 83
C0911A .................................. 83
C0912A .................................. 83
C0913A .................................. 83
C0914A .................................. 83
C0915A .................................. 83
C0916A .................................. 83
C0917A .................................. 83
241
Electronics
Technical Information
Part Number Index
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
page
page
page
page
C1118 .................................. 139
C1119 .................................. 139
C1123 .................................. 139
C1124 .................................. 139
C1126 .................................. 139
C1130 .................................. 139
C1135 .................................. 101
C1142 .................................. 101
C1154 .................................... 94
C1155 .................................. 100
C1156 .................................. 110
C1158 .................................. 105
C1160 .................................... 96
C1162 .................................. 109
C1164 .................................. 109
C1166 .................................. 100
C1176A ................................ 111
C1178 .................................. 100
C1180 .................................... 94
C1188 .................................. 100
C1198 .................................... 94
C1201 .................................. 175
C1202 ............................ 41, 175
C1203 .................................... 41
C1204 .................................... 41
C1206 .................................... 41
C1208 .................................... 41
C1210 .................................... 41
C1212 .................................... 41
C1226A ................................ 173
C1228A ................................ 171
C1300 .................................. 172
C1301 .................................. 172
C1302 ............................ 40, 172
C1304 .................................... 40
C1305 .................................... 40
C1308 .................................... 40
C1310 .................................... 40
C1312 .................................... 40
C1313 .................................... 40
C1318 ...................................... 7
C1319 ...................................... 7
C1320A .................................... 7
C1321 ...................................... 7
C1322A ................................ 174
C1326 ...................................... 7
C1331A ................................ 160
C1332A .................................. 36
C1333A ................................ 159
C1335A .................................. 33
C1337A .................................. 33
C1338A ................................ 161
C1340A ................................ 160
C1341A .................................. 33
C1343A ................................ 160
C1345A ................................ 159
C1350A .................................. 60
C1352A .................................. 58
C1353A .................................. 58
C1356 .................................. 156
C1357 .................................. 156
C1358 .................................. 156
C1360 .................................. 156
C1361 .................................. 156
C1362 .................................. 156
C1363 .................................. 156
C1364 .................................. 157
C1368A .................................. 80
C1458.15.90 ........................ 151
C1458.55.90 ........................ 151
C1458.56.90 ........................ 151
C1458.57.90 ........................ 151
C1461.15.90 ........................ 151
C1461.55.90 ........................ 151
C1461.56.90 ........................ 151
C1461.57.90 ........................ 151
C1463.15.90 ........................ 151
C1463.55.90 ........................ 151
C1463.56.90 ........................ 151
C1558.15.92 ........................ 155
C1561.15.92 ........................ 155
C1563.15.92 ........................ 155
C1602 ............................ 41, 175
C1603 .................................... 41
C1604 .................................... 41
C1606 .................................... 41
C1608 .................................... 41
C1612 .................................... 41
C1614 .................................... 41
C1642A .................................. 35
C1643A .................................. 35
C1644A .................................. 35
C1645A .................................. 35
C1646A .................................. 35
C1648A .................................. 38
C1670A .................................. 46
C1671A .................................. 46
C1672A .................................. 46
C2428A .................................. 14
C2429A .................................. 14
C2430A .................................. 14
C2431A .................................. 14
C2433A .................................. 13
C2434A .................................. 14
C2435A .................................. 14
C2436A .................................. 14
C2437A .................................. 14
C2440A .................................. 14
C2443A .................................. 14
C2461A .................................. 11
C2462A .................................. 11
C2463A .................................. 11
C2464A .................................. 11
C2465A .................................. 11
C2466A .................................. 11
C2467A .................................. 11
C2470A .................................. 11
C2471A .................................. 11
C2473A .................................. 11
C2488A .................................. 11
C2509A ................................ 164
C2510A ................................ 164
C2511A ................................ 164
C2513A .................................. 23
C2514A .................................. 23
C2515A .................................. 23
C2516A .................................. 23
C2517A .................................. 23
C2518A .................................. 24
C2519A .................................. 24
C2520A .................................. 24
C2521A .................................. 24
C2523A .................................. 23
C2524A .................................. 23
C2525A .................................. 23
C2526A .................................. 23
C2528A .................................. 23
C2534A .................................. 23
C2535A .................................. 23
C2536A .................................. 23
C2537A .................................. 23
C2538A .................................. 23
C2539A .................................. 23
C2540A .................................. 23
C2543A .................................. 25
C2555A .................................. 23
C2676A .................................. 34
C1673A .................................. 46
C1676A .................................. 46
C1700 .................................. 152
C1701 .................................. 152
C1702 .................................. 152
C1703 .................................. 152
C1704 .................................. 152
C1705 .................................. 152
C1800 .................................. 153
C1801 .................................. 153
C1802 .................................. 153
C1803 .................................. 153
C1804 .................................. 153
C1805 .................................. 153
C2003A .................................... 2
C2004A .................................... 2
C2015A .................................... 2
C2016A .................................... 2
C2028A .................................... 2
C2040A .................................... 2
C2052A .................................... 2
C2053A .................................... 2
C2064A .................................... 2
C2065A .................................... 2
C2100A .................................... 3
C2101A .................................... 3
C2102A .................................... 3
C2103A .................................... 3
C2104A .................................... 3
C2105A .................................... 3
C2106A .................................... 3
C2107A .................................... 3
C2117A .................................... 3
C2118A .................................... 3
C2119A .................................... 3
C2404A .................................. 13
C2405A .................................. 14
C2406A .................................. 14
C2409A .................................. 14
C2410A .................................. 14
C2412A .................................. 13
C2420A .................................. 13
C2421A .................................. 13
C2422A .................................. 13
C2423A .................................. 13
C2424A .................................. 13
C2425A .................................. 14
C2426A .................................. 14
C2427A .................................. 14
242
Technical Information
Electronics
Part Number Index
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
page
page
page
page
C2677A .................................. 34
C2678A .................................. 36
C2679A .................................. 36
C2680A .................................. 36
C2681A .................................. 36
C2683A .................................. 36
C2686A .................................. 36
C2687A .................................. 36
C2688A .................................. 36
C2689A .................................. 36
C2754A .................................... 9
C2768A .................................. 33
C2830A .................................. 13
C2831A .................................. 13
C2882A .................................. 33
C2888A .................................. 33
C2892A .................................. 33
C2895A .................................. 33
C3028 .................................... 56
C3029 .................................... 56
C3030 .................................... 56
C3031 .................................... 56
C3060 .................................... 28
C3061 .................................... 28
C3062 .................................... 28
C3063 .................................... 28
C3064 .................................... 28
C3065 .................................... 28
C3068 .................................... 28
C3102 .................................... 16
C3103 .................................... 16
C3105 .................................... 16
C3106 .................................... 16
C3110 .................................... 17
C3111 .................................... 17
C3112 .................................... 17
C3113 .................................... 17
C3114 .................................... 17
C3115 .................................... 17
C3116 .................................... 17
C3117 .................................... 17
C3118 .................................... 17
C3119 .................................... 17
C3120 .................................... 17
C3121 .................................... 17
C3122 .................................... 17
C3123 .................................... 17
C3124 .................................... 17
C3125 .................................... 17
C3126 .................................... 16
C3127 .................................... 17
C3128 .................................... 17
C3129 .................................... 17
C3134 .................................... 16
C3135 .................................... 16
C3150 .................................... 48
C3151 .................................... 48
C3152 .................................... 48
C3153 .................................... 48
C3154 .................................... 27
C3155 .................................... 27
C3156 .................................... 61
C3157 .................................... 61
C3158 .................................... 28
C3159 .................................... 28
C3162 .................................... 27
C3163 .................................... 27
C3164 .................................... 27
C3165 .................................... 48
C3166 .................................... 27
C3167 .................................. 128
C3168 .................................. 128
C3169 .................................... 27
C3170 .................................. 128
C3171 .................................. 128
C3172 .................................. 128
C3173 .................................. 128
C3174 .................................. 128
C3175 .................................. 128
C3178 .................................... 16
C3179 .................................... 16
C3180 .................................... 27
C3181 .................................... 27
C3182 .................................... 27
C3183 .................................... 28
C3184 .................................... 28
C3190 .................................... 16
C3191 .................................... 16
C3192 .................................... 16
C3193 .................................... 16
C3194 .................................... 16
C3195 .................................... 16
C3200 .................................. 122
C3201 .................................. 122
C3204 .................................... 48
C3205 .................................... 48
C3206 .................................... 48
C3207 .................................... 48
C3527 .................................. 104
C3528 .................................... 97
C3529 .................................... 98
C3602 .................................... 21
C3603 .................................... 21
C3604 .................................... 21
C3605 .................................... 21
C3606 .................................... 21
C3607 .................................... 21
C3608 .................................... 21
C3610 .................................... 21
C4008A .............................. 9, 43
C4010A .................................. 43
C4014A .................................. 43
C4015A .................................. 43
C4017A .................................. 43
C4062A .................................. 12
C4063A .................................. 12
C4064A .................................. 12
C4065A .................................. 12
C4066A .................................. 12
C4067A .................................. 12
C4070A .................................. 12
C4071A .................................. 12
C4073A .................................. 12
C4075A .................................. 12
C4076A .................................. 12
C4077A .................................. 12
C4078A .................................. 12
C4079A .................................. 12
C4080 .................................. 139
C4081A .................................. 10
C4082A .................................. 10
C4083A .................................. 10
C4084A .................................. 10
C4088A .................................. 12
C4090 .................................. 139
C4100A .................................. 18
C4101A .................................. 18
C4102A .................................. 18
C4103A .................................. 18
C4104A .................................. 18
C4105A .................................. 18
C4106A .................................. 18
C4107A .................................. 18
C4108A .................................. 18
C4109A .................................. 18
C4110A .................................. 18
C4111A .................................. 18
C3208 .................................... 48
C3210 .................................. 122
.................................. 122
C3211
C3214 .................................... 55
C3215 .................................... 55
C3216 .................................... 55
C3217 .................................... 55
C3218 .................................... 55
C3220 .................................. 122
C3223 .................................. 122
C3224 .................................. 122
C3225 .................................. 122
C3240 .................................. 127
C3241 .................................. 127
C3242 .................................. 127
C3243 .................................. 127
C3244 .................................. 127
C3245 .................................. 127
C3246 .................................. 127
C3247 .................................. 127
C3260 .................................. 124
C3261 .................................. 124
C3270 .................................. 124
C3271 .................................. 124
C3280 .................................. 124
C3282 .................................. 124
C3283 .................................. 124
C3284 .................................. 124
C3310 .................................... 27
C3311 .................................... 27
C3320 .................................... 27
C3321 .................................... 27
C3322 .................................... 27
C3340 .................................... 27
C3341 .................................... 27
C3352 .................................... 52
C3353 .................................... 52
C3354 .................................... 52
C3356 .................................... 52
C3362 .................................... 52
C3364 .................................... 52
C3500 .................................. 104
C3519 .................................. 100
C3520 .................................. 109
C3521 .................................... 91
C3523 .................................... 91
C3524 .................................... 91
C3525 .................................... 91
C3526 .................................. 104
243
Electronics
Technical Information
Part Number Index
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
page
page
page
page
C4112A .................................. 18
C4113A .................................. 18
C4114A .................................. 18
C4115A .................................. 18
C4116A .................................. 18
C4117A .................................. 19
C4118A .................................. 19
C4119A .................................. 19
C4120A .................................. 19
C4121A .................................. 19
C4122A .................................. 19
C4123A .................................. 19
C4124A .................................. 19
C4125A .................................. 19
C4126A .................................. 19
C4127A .................................. 19
C4128A .................................. 19
C4129A .................................. 19
C4130A .................................. 19
C4131A .................................. 19
C4132A .................................. 19
C4133A .................................. 19
C4134A .................................. 19
C4135A .................................. 20
C4136A .................................. 20
C4137A .................................. 20
C4138A .................................. 20
C4139A .................................. 20
C4140A .................................. 20
C4141A .................................. 20
C4142A .................................. 20
C4143A .................................. 20
C4144A .................................. 20
C4145A .................................. 20
C4146A .................................. 20
C4147A .................................. 20
C4148A .................................. 20
C4149A .................................. 20
C4150A .................................. 20
C4151A .................................. 20
C4152A .................................. 29
C4153A .................................. 29
C4154A .................................. 29
C4155A .................................. 29
C4156A .................................. 29
C4157A .................................. 29
C4158A .................................. 29
C4159A .................................. 29
C4160A .................................. 29
C4161A .................................. 29
C4162A .................................. 29
C4163A .................................. 29
C4164A .................................. 29
C4165A .................................. 29
C4166A .................................. 30
C4167A .................................. 29
C4168A .................................. 29
C4169A .................................. 29
C4170A .................................. 53
C4171A .................................. 53
C4172A .................................. 53
C4173A .................................. 53
C4174A .................................. 53
C4175A .................................. 53
C4176A .................................. 53
C4177A .................................. 53
C4178A .................................. 53
C4179A .................................. 53
C4180A .................................. 53
C4181A .................................. 53
C4182A .................................. 53
C4183A .................................. 54
C4184A .................................. 54
C4185A .................................. 54
C4186A .................................. 54
C4187A .................................. 54
C4188A .................................. 54
C4189A .................................. 54
C4190A .................................. 54
C4191A .................................. 53
C4192A .................................. 30
C4193A .................................. 30
C4194A .................................. 30
C4195A .................................. 30
C4196A .................................. 30
C4197A .................................. 30
C4198A .................................. 30
C4199A .................................. 30
C4200A .................................. 30
C4201A .................................. 30
C4202A .................................. 30
C4203A .................................. 59
C4204A .................................. 30
C4205A .................................. 30
C4206A .................................. 19
C4207A .................................. 30
C4208A .................................. 30
C4209A .................................. 53
C4331A ................................ 129
C4332A ................................ 129
C4333A ................................ 129
C4334A ................................ 120
C4335A ................................ 120
C4336A ................................ 120
C4337A ................................ 120
C4338A ................................ 120
C4339A ................................ 120
C4340A ................................ 120
C4341A ................................ 120
C4342A ................................ 120
C4343A ................................ 120
C4344A ................................ 120
C4345A ................................ 120
C4346A ................................ 120
C4347A ................................ 120
C4348A ................................ 120
C4349A ................................ 118
C4350A ................................ 120
C4408 .................................. 138
C4408ST .............................. 138
C4410 .................................. 138
C4412 .................................. 138
C4412ST .............................. 138
C4413 .................................. 138
C4841A .................................. 76
C4842A .................................. 76
C4843A .................................. 76
C4844A .................................. 76
C5011 .................................... 96
C5025 .................................... 96
C5029 .................................... 96
C5034 .................................... 96
C5039 .................................... 97
C5043 .................................... 98
C5044 .................................... 97
C5076 .................................. 139
C5078 .................................. 139
C5084 .................................. 139
C5086 .................................. 139
C5096 .................................. 139
C5460 .................................. 139
C5760 .................................... 88
C5761 .................................... 88
C5770 .................................. 103
C5775 .................................... 88
C5776 .................................... 88
C5777 .................................... 89
C4210A .................................. 30
C4211A .................................. 30
C4212A .................................. 30
C4213A .................................. 30
C4214A .................................. 19
C4215A .................................. 30
C4216A .................................. 31
C4217A .................................. 31
C4218A .................................. 31
C4219A .................................. 31
C4220A .................................. 31
C4221A .................................. 31
C4222A .................................. 31
C4223A .................................. 31
C4224A .................................. 31
C4225A .................................. 31
C4226A .................................. 31
C4227A .................................. 31
C4228A .................................. 31
C4229A .................................. 31
C4230A .................................. 31
C4300A ................................ 118
C4301A ................................ 118
C4302A ................................ 118
C4304A ................................ 118
C4305A ................................ 118
C4306A ................................ 118
C4307A ................................ 118
C4308A ................................ 118
C4309A ................................ 118
C4310A ................................ 118
C4311A .................................... 9
C4312A ................................ 118
C4313A ................................ 118
C4314A ................................ 118
C4315A ................................ 118
C4316A ................................ 118
C4317A ................................ 118
C4318A ................................ 118
C4321A ................................ 118
C4322A ................................ 118
C4323A ................................ 118
C4324A ................................ 118
C4325A ................................ 118
C4326A ................................ 118
C4327A ................................ 118
C4328A ................................ 129
C4329A ................................ 129
C4330A ................................ 129
244
Technical Information
Electronics
Part Number Index
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
page
page
page
page
C5778 .................................... 91
C5780 .................................. 103
C5784 .................................. 103
C5785 .................................... 89
C5802 .................................... 89
C5804 .................................... 89
C5814 .................................... 90
C5822 .................................... 90
C5830 .................................. 103
C5886 .................................... 88
C5889 .................................... 89
C6010A .................................. 43
C6014A .................................. 43
C6015A .................................. 43
C6017A .................................. 43
C6019A .................................. 43
C6023A .................................. 43
C6026A .................................. 43
C6035A .................................. 81
C6036A .................................. 81
C6040A .................................. 82
C6041A .................................. 82
C6042A .................................. 82
C6043A .................................. 82
C6044A .................................. 82
C6045A .................................. 82
C6046A .................................. 82
C6047A .................................. 82
C6048A .................................. 82
C6049A .................................. 82
C6050A .................................. 82
C6051A .................................. 82
C6052A .................................. 82
C6053A .................................. 82
C6054A .................................. 82
C6056A .................................. 82
C6058A .................................. 82
C6059A .................................. 82
C6060A .................................. 82
C6061A ................................ 165
C6062A ................................ 165
C6065A .................................. 82
C6066A .................................. 82
C6067A .................................. 82
C6101A .................................. 44
C6103A .................................. 44
C6106A .................................. 44
C6109A .................................. 44
C6111A .................................. 44
C6118A .................................. 44
C6119A .................................. 44
C6120A .................................. 44
C6121A .................................. 44
C6310 .................................. 138
C6311 .................................. 138
C6312 .................................. 138
C6313 .................................. 138
C6348A .................................. 12
C6351A .................................. 13
C6352A .................................. 13
C6353A .................................. 13
C6355A .................................. 13
C6356A .................................. 13
C6357A .................................. 13
C6358A .................................. 13
C6360A .................................. 13
C6367 .................................. 157
C6451A .................................. 47
C6500A .................................. 37
C6501A .................................. 37
C6502A .................................. 37
C6503A .................................. 37
C6504A .................................. 37
C6505A .................................. 37
C6506A .................................. 37
C6507A .................................. 37
C6508A .................................. 37
C7102A ................................ 156
C7104A .................................. 46
C7106A .................................. 58
C7108A .................................... 7
C7112A .................................. 66
C7114A .................................. 66
C7116A .................................. 66
C7600A .................................... 4
C7602A .................................... 4
C7604A .................................... 4
C7606A .................................... 4
C7608A .................................... 4
C7610A .................................... 4
C7611A .................................... 4
C8000 .................................. 112
C8001 .................................. 112
C8014 .................................. 112
C8025 .................................. 102
C8027 .................................. 104
C8028 .................................. 104
C8029 .................................... 91
CP6.30.06 ............................ 144
CP6.30.07 ............................ 144
CP6.30.10 ............................ 144
CP6.A3.02 ............................ 144
CP6.A3.03 ............................ 144
CP6.A3.05 ............................ 144
CP6.A3.06 ............................ 144
CP6.A3.07 ............................ 144
CP6.A3.10 ............................ 144
CR5.30.02 ............................ 145
CR5.30.03 ............................ 145
CR5.30.05 ............................ 145
CR5.30.06 ............................ 145
CR5.30.07 ............................ 145
CR5.30.10 ............................ 145
CR5.A3.02 ............................ 145
CR5.A3.03 ............................ 145
CR5.A3.05 ............................ 145
CR5.A3.06 ............................ 145
CR5.A3.07 ............................ 145
CR5.A3.10 ............................ 145
CR6.30.02 ............................ 144
CR6.30.03 ............................ 144
CR6.30.05 ............................ 144
CR6.30.06 ............................ 144
CR6.30.07 ............................ 144
CR6.30.10 ............................ 144
CR6.A3.02 ............................ 144
CR6.A3.03 ............................ 144
CR6.A3.05 ............................ 144
CR6.A3.06 ............................ 144
CR6.A3.07 ............................ 144
CR6.A3.10 ............................ 144
E1000S ................................. 134
E1001S ................................. 134
E1002S ................................. 134
E1003S ................................. 134
E1004S ................................. 134
E1006S ................................. 134
E1008S ................................. 134
E1010S ................................. 134
E1012S ................................. 134
E1022S ................................. 134
E1023S ................................. 134
E1024S ................................. 134
E1030S ................................. 134
E1032S ................................. 134
E1033S ................................. 134
E1034S ................................. 134
C8030 .................................. 101
C8031 .................................... 91
C8101 .................................... 49
C8102 .................................... 15
.................................... 49
C8103
C8104 .................................... 49
C8105 .................................... 62
C8106 .................................... 26
C8107 .................................... 39
C8108 .................................... 39
C8109 .................................... 49
C8110 .................................... 39
C8111 .................................... 39
C8112 .................................... 63
C8113 .................................... 51
C8114 .................................... 26
C8115 .................................... 39
C8116 .................................... 45
C8117 .................................... 57
C8118 .................................... 50
C8119 .................................... 39
C8120 .................................... 39
C8122 .................................... 45
C8123 .................................... 51
C8124 .................................... 51
C8125 .................................. 185
C8126 .................................... 51
C8127 .................................... 51
C8128 .................................... 64
C8129 .................................... 57
C8131 .................................... 62
C8132 .................................... 63
C8133 .................................... 62
C8134 .................................... 62
CP5.30.02 ............................ 145
CP5.30.03 ............................ 145
CP5.30.05 ............................ 145
CP5.30.06 ............................ 145
CP5.30.07 ............................ 145
CP5.30.10 ............................ 145
CP5.A3.02 ............................ 145
CP5.A3.03 ............................ 145
CP5.A3.05 ............................ 145
CP5.A3.06 ............................ 145
CP5.A3.07 ............................ 145
CP5.A3.10 ............................ 145
CP6.30.02 ............................ 144
CP6.30.03 ............................ 144
CP6.30.05 ............................ 144
245
Electronics
Technical Information
Part Number Index
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
page
page
page
page
E1036S ................................. 134
E1038S ................................. 134
E1040S ................................. 134
E1041S ................................. 134
E1042S ................................. 134
E1043S ................................. 134
E1044S ................................. 134
E1052S ................................. 134
E1054S ................................. 134
E1062S ................................. 134
E1064S ................................. 134
E1482S ................................. 117
E1484S ................................. 117
E1486S ................................. 117
E1502S ................................. 117
E1503S ................................. 117
E1504S ................................. 117
E1505S ................................. 117
E1506S ................................. 117
E1508S ................................. 117
E1512S ................................. 117
E1514S ................................. 117
E1522S ................................. 117
E1524S ................................. 117
E1532S ................................. 117
E1534S ................................. 117
E1842S ................................. 162
E1843S ................................. 162
E2000S ................................. 135
E2002S ................................. 135
E2003S ................................. 135
E2004S ................................. 135
E2006S ................................. 135
E2008S ................................. 135
E2010S ................................. 135
E2012S ................................. 135
E2022S ................................. 135
E2023S ................................. 135
E2024S ................................. 135
E2030S ................................. 135
E2032S ................................. 135
E2033S ................................. 135
E2034S ................................. 135
E2036S ................................. 135
E2038S ................................. 135
E2040S ................................. 135
E2041S ................................. 135
E2042S ................................. 135
E2043S ................................. 135
E2044S ................................. 135
E2052S ................................. 135
E2054S ................................. 135
E2062S ................................. 135
E2064S ................................. 135
E2100S ................................. 137
E2102S ................................. 137
E2103S ................................. 137
E2104S ................................. 137
E2106S ................................. 137
E2108S ................................. 137
E2122S ................................. 137
E2123S ................................. 137
E2124S ................................. 137
E2200S ................................. 137
E2202S ................................. 137
E2203S ................................. 137
E2204S ................................. 137
E2206S ................................. 137
E2208S ................................. 137
E2242S ................................. 137
E2243S ................................. 137
E2244S ................................. 137
E2252S ................................. 137
E2254S ................................. 137
E2262S ................................. 137
E2264S ................................. 137
E2402S ................................. 117
E2404S ................................. 117
E2406S ................................. 117
E2482S ................................. 119
E3503S ................................. 121
E3504S ................................. 121
E3506S ................................. 121
E3512S ................................. 121
E3514S ................................. 121
E3522S ................................. 121
E3524S ................................. 121
E3532S ................................. 121
E3534S ................................. 121
E3542S ................................. 123
E3602S ................................. 123
E3603S ................................. 123
E3604S ................................. 123
E3606S ................................. 123
E3612S ................................. 123
E3614S ................................. 123
E3622S ................................. 123
E3624S ................................. 123
E3632S ................................. 123
E3634S ................................. 123
E3842S ................................. 162
E3843S ................................. 162
EO24C0045510 .................... 184
EO26C0045510 .................... 184
EO28C0045510 .................... 184
EO28P0181510 .................... 184
EO28P0501510 .................... 184
EO30C0045510 .................... 184
SP00C0011010 .................... 182
SP00C0012010 .................... 182
Z028C0061110 .................... 183
Z028C0066110 .................... 184
ZO28C0042010 .................... 184
ZO28C0042210 .................... 184
ZO28C0042410 .................... 184
ZO28C0042610 .................... 184
ZO28C0042810 .................... 184
ZO28C0101120 .................... 184
E2484S ................................. 119
E2502S ................................. 119
E2503S ................................. 119
E2504S ................................. 119
E2506S ................................. 119
E2508S ................................. 119
E2522S ................................. 119
E2524S ................................. 119
E2532S ................................. 119
E2534S ................................. 119
E2542S ................................. 119
E2544S ................................. 119
E3000S ................................. 136
E3001S ................................. 136
E3002S ................................. 136
E3003S ................................. 136
E3004S ................................. 136
E3006S ................................. 136
E3008S ................................. 136
E3010S ................................. 136
E3012S ................................. 136
E3022S ................................. 136
E3023S ................................. 136
E3024S ................................. 136
E3030S ................................. 136
E3032S ................................. 136
E3033S ................................. 136
E3034S ................................. 136
E3036S ................................. 136
E3038S ................................. 136
E3042S ................................. 136
E3043S ................................. 136
E3044S ................................. 136
E3052S ................................. 136
E3054S ................................. 136
E3062S ................................. 136
E3064S ................................. 136
E3482S ................................. 121
E3484S ................................. 121
E3502S ................................. 121
246
相关型号:
C2016.12.03
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 22, Conductor/Strands: 7/30
GENERAL
C2016.12.06
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 22, Conductor/Strands: 7/30
GENERAL
C2016.21.01
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 22, Conductor/Strands: 7/30
GENERAL
C2016.21.02
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 22, Conductor/Strands: 7/30
GENERAL
C2016.21.03
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 22, Conductor/Strands: 7/30
GENERAL
C2016.21.04
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 22, Conductor/Strands: 7/30
GENERAL
C2016.21.05
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 22, Conductor/Strands: 7/30
GENERAL
C2016.21.06
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 22, Conductor/Strands: 7/30
GENERAL
C2016.21.07
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 22, Conductor/Strands: 7/30
GENERAL
©2020 ICPDF网 联系我们和版权申明