390SS010M32 [GLENAIR]
Submersible EMI/RFI Cable Sealing Backshell with Strain Relief; 潜水EMI / RFI电缆密封后壳与应变救灾型号: | 390SS010M32 |
厂家: | Glenair |
描述: | Submersible EMI/RFI Cable Sealing Backshell with Strain Relief |
文件: | 总2页 (文件大小:60K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
390-010
Submersible EMI/RFI Cable Sealing Backshell
withStrain Relief
Type C - Direct Coupling - Low Profile
390 F S 010 M 16 10 E 6
CONNECTOR
DESIGNATORS
Product Series
Length: S only
(1/2 inch increments:
e.g. 6 = 3 inches)
A-B*-C-D-E-F
G-H-J-K-L-S
Connector
Designator
Strain Relief Style (C, E)
Cable Entry (Tables X, XI)
Shell Size (Table I)
Angle and Profile
A = 90
* Conn. Desig. B See Note 6
B = 45
S = Straight
DIRECT COUPLING
Basic Part No.
Finish (Table II)
TYPE C OVERALL
SHIELD TERMINATION
Length ± .060 (1.52)
Min. Order Length 2.0 Inch
(See Note 4)
Length *
O-Rings
.937 (23.8)Approx
A Thread
(Table I)
* Length
± .060 (1.52)
Min. Order
Length 1.5 Inch
(See Note 4)
B
(Table I)
STYLE 2
(STRAIGHT
See Note 1)
J
G
J
E
(Table
IV)
(Table (Table
III) IV)
(Table III)
B
B
F (Table IV)
(Table I)
(Table I)
H
(Table IV)
STYLE C
STYLE E
Medium Duty
(Table X)
Medium Duty
(Table XI)
Clamping
Bars
T
X (See
Note 5)
Y
Cable
Range
Cable
Range
W
Z
© 2005 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com
Series 39 - Page 36
390-010
Submersible EMI/RFI Cable Sealing Backshell
withStrain Relief
Type C - Direct Coupling - Low Profile
See inside back cover fold-out or pages 13 and 14 for Tables I and II.
TABLE III: FRONTADAPTER
J Max - Conn. Designator
A-E-F
TABLE IV: ELBOW DIMENSIONS
Elbow
Size
E
F
G
H
Max
Shell
Size
Max
Max
Max
J-H-L-S
D-B-G-K
C
04 .630 (16.0) 2.715 (69.0) .636 (16.2) 2.725 (69.2)
06 .630 (16.0) 2.775 (70.5) .710 (18.0) 2.845 (72.3)
08 .692 (17.6) 2.835 (72.0) .731 (18.6) 2.865 (72.8)
10 .755 (19.2) 3.554 (90.3) .825 (21.0) 3.564 (90.5)
12 .848 (21.5) 3.664 (93.1) .988 (25.1) 3.654 (92.8)
16 1.036 (26.3) 3.854 (97.9) 1.087 (27.6) 3.824 (97.1)
20 1.130 (28.7) 4.192 (106.5) 1.325 (33.7) 4.122 (104.7)
24 1.255 (31.9) 4.225 (107.3) 1.337 (34.0) 4.275 (108.6)
28 1.317 (33.5) 4.325 (109.9) 1.827 (46.4) 4.525 (114.9)
32 1.348 (34.2) 4.465 (113.4) 2.027 (51.5) 4.575 (116.2)
08/09 1.180 (30.0) 1.250 (31.8)
10/11 1.180 (30.0) 1.250 (31.8)
12/13 1.180 (30.0) 1.250 (31.8) 1.735 (44.1)
14/15 1.180 (30.0) 1.250 (31.8) 1.915 (48.6)
16/17 1.380 (35.0) 1.560 (39.6) 1.915 (48.6)
18/19 1.380 (35.0) 1.560 (39.6) 1.915 (48.6)
20/21 1.380 (35.0) 1.560 (39.6) 1.915 (48.6)
22/23 1.380 (35.0) 1.560 (39.6) 1.915 (48.6)
24/25 1.380 (35.0) 1.560 (39.6) 1.915 (48.6)
28/29 1.610 (40.9) 1.560 (39.6) 1.915 (48.6)
32/33 1.610 (40.9) 1.750 (44.5) 1.915 (48.6)
36 1.610 (40.9) 1.750 (44.5) 1.915 (48.6)
40 1.610 (40.9) 2.190 (55.6) 1.915 (48.6)
TABLE X: CABLE ENTRY
T
Max
Cable Range
Dash
No.
03
04
06
08
10
12
16
20
24
28
32
W
Max
X
Ref
Min
Max
1.219 (31.0)
1.219 (31.0)
1.219 (31.0)
1.219 (31.0)
1.281 (32.5)
1.281 (32.5)
1.406 (35.7)
1.656 (42.1)
1.906 (48.4)
1.906 (48.4)
2.000 (50.8)
.812 (20.6)
.937 (23.8)
1.062 (27.0)
1.188 (30.2)
1.312 (33.3)
1.562 (39.7)
1.750 (44.5)
2.250 (57.2)
2.375 (60.3)
2.625 (66.7)
2.812 (71.4)
.135 (3.4)
.203 (5.2)
.285 (7.2)
.350 (8.9)
.390 (9.9)
.460 (11.7)
.510 (13.0)
.695 (17.7)
.715 (18.2)
.915 (23.2)
1.070 (27.2)
.156 (4.0)
.188 (4.8)
.281 (7.1)
.312 (7.9)
.375 (9.5)
.500 (12.7)
.625 (15.9)
.938 (23.8)
1.000 (25.4)
1.250 (31.8)
1.500 (38.1)
.219 (5.6)
.312 (7.9)
.438 (11.1)
.531 (13.5)
.625 (15.9)
.750 (19.1)
.938 (23.8)
1.250 (31.8)
1.375 (34.9)
1.625 (41.3)
1.875 (47.6)
1. When maximum cable entry
(page 22) is exceeded, Style 2
will be supplied. (Function S
only).
2. Metric dimensions (mm) are
indicated in parentheses.
3. Cable range is defined as the
accommodations range for the
wire bundle or cable. Dimen-
sions shown are not intended
for inspection criteria.
4. Consult factory for shorter
lengths on straight backshells.
5. Saddles are bottomed on
Clamp Ears.
6. When using Connector Desig-
nator B refer to pages 18 and 19
for part number development.
TABLE XI: CABLE ENTRY
Z
Cable Range
Y
Max
Dash
No.
03
04
06
08
10
12
16
20
24
28
32
Max
Min
Max
.739 (18.8)
.739 (18.8)
.739 (18.8)
.739 (18.8)
.791 (20.1)
.880 (22.4)
.901 (22.9)
1.031 (26.2)
1.250 (31.8)
1.250 (31.8)
1.312 (33.3)
.812 (20.6)
.937 (23.8)
1.062 (27.0)
1.188 (30.2)
1.312 (33.3)
1.562 (39.7)
1.750 (44.5)
2.250 (57.2)
2.375 (60.3)
2.625 (66.7)
2.812 (71.4)
.156 (4.0)
.188 (4.8)
.281 (7.1)
.312 (7.9)
.375 (9.5)
.500 (12.7)
.625 (15.9)
.938 (23.8)
1.000 (25.4)
1.250 (31.8)
1.500 (38.1)
.219 (5.6)
.312 (7.9)
.438 (11.1)
.531 (13.5)
.625 (15.9)
.750 (19.1)
.938 (23.8)
1.250 (31.8)
1.375 (34.9)
1.625 (41.3)
1.875 (47.6)
© 2005 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com
Series 39 - Page 37