805-009-BB6M8-4PA [GLENAIR]
Cordsets For Harsh Environments; 接插件适用于恶劣环境型号: | 805-009-BB6M8-4PA |
厂家: | Glenair |
描述: | Cordsets For Harsh Environments |
文件: | 总2页 (文件大小:120K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series 805 “Mighty Mouse”
Triple-Start
805 Series Cordsets For Harsh Environments
A
B
C
D
E
F
Glenair’s ASAP “Mighty Mouse”
overmolded cordsets offer
Two Jacket Types Extruded
Estane polyurethane jacket resists
abrasion, provides excellent flexibility.
Withstands continuous exposure to
weather and solvents. Or, choose
low smoke/ zero halogen jacket for
installation where combustion toxicity
is a concern. Both jackets are UL 94
V-0.
watertight sealing and excellent cold
temperature flexibility. These cables
are 100% tested and ready to use.
Standard overmolded cables feature
polyurethane jackets or rubber
jackets with flexible strain reliefs.
Simplified Ordering, No Minimums
ASAP cordsets are made-to-order
from stocked connectors and cable.
Choose #22 or #24 AWG cable with
standard Estane jacket for best
availability.
Shielded 90% braid coverage and
BAND-IT® shield termination meet
EMI requirements.
Series 805 Overmolded
Cordset
HOW TO ORDER
Sample Part Number
805-008
-A
C
4
NF
18-55
P
A
-72
End A
End B
Wire Shell Material /
Protective Shell
Series
Connector Connector Size
Finish
Insert Arr.
Cover
Key Pos. Length
805-008
Overmolded
Cordset,
-A
A
2
C
8-4
8-7
4 #23
7 #23
P
A
Overall
Length In
Inches
G
H
J
#22 AWG
(Std.)
Plug, with
Male Pin
Contacts
Plug, with
Male Pin
Contacts
Aluminum / Black
Anodize
Metal
Position A
(Normal)
Protective
Covers
Included
9-10 10 #23
10-13 13 #23
11-19 19 #23
12-26 26 #23
15-37 37 #23
18-55 55 #23
19-85 85 #23
Shielded, with
Polyurethane
Cable Jacket
4
M
B
12 Inch
Min.
#24 AWG
(Std.)
Aluminum /
Electroless
Nickel
Position B
-B
B
Plug, with
Female
Socket
Plug, with
Female
Socket
C
Position C
805-009
Overmolded
Cordset,
6
N
#26 AWG
No Covers
Supplied
NF
D
Contacts
Contacts
Aluminum /
Cadmium with
Olive Drab
Chromate
Position D
8
Shielded,
with Low
#28 AWG
-C
C
Receptacle, Receptacle,
Smoke/ Zero
Halogen
with Male
with Male
Pin Contacts Pin Contacts
Jacket
ZN
Aluminum / Zinc-
Nickel with Olive
Drab Chromate
K
L
-D
D
Receptacle, Receptacle,
with Female with Female
Socket
Contacts
Socket
Contacts
ZNU
Aluminum / Zinc-
Nickel with Black
Chromate
N
No
Connector
(Single-
Ended)
Z1
Stainless Steel /
Passivated
M
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com
H-14
Rev. 05-APR-2007
Series 805 “Mighty Mouse”
Triple-Start
805 Series Cordsets For Harsh Environments
A
B
C`
D
E
LENGTH
+ 2.0/-0.0 (+50.8/ -0.0)
12 IN. (300 mm.) MIN.
A MAX.
SERIES 805 RECEPTACLE
SHIELDED JACKETED
CABLE
B MAX.
POLYAMIDE
OVERMOLDED STRAIN
RELIEF
OPTIONAL
PROTECTIVE COVER
WITH POLYURETHANE
WIRE ROPE
SERIES 805 PLUG
RIGHT ANGLE CORDSETS
DIMENSIONS
A Max. B Max. C Max. D Max. E Max.
Size In. mm. In. mm. In. mm. In. mm. In. mm.
Shell
LENGTH + 2.0/-0.0 (+50.8/ -0.0)
MASTER
12 IN. (300 mm.) MIN.
KEY
LOCATED 180°
C MAX.
2.500 63.50 .560 14.22 1.500 38.10 .560 14.22 1.650 41.91
2.500 63.50 .680 17.27 1.700 43.18 .680 17.27 1.700 43.18
2.500 63.50 .740 18.80 1.750 44.45 .740 18.80 1.750 44.45
2.500 63.50 .810 20.57 1.750 44.45 .810 20.57 1.750 44.45
2.750 69.85 .870 22.10 1.750 44.45 .870 22.10 1.750 44.45
3.000 76.20 .930 23.62 1.750 44.45 .930 23.62 1.750 44.45
3.500 88.90 1.120 28.45 1.750 44.45 1.120 28.45 1.750 44.45
3.750 95.25 1.180 29.97 2.000 50.80 1.180 29.97 2.000 50.80
8
9
FROM CABLE EXIT
10
11
12
15
18
19
E
MAX.
D
MAX.
How To Order Right Angle Cordsets
F
Insert the letter “R” after the End A or End B
Connector letter designator.
Example
Straight cable 805-008-AC4NF18-55PA-72
G
H
Right Angle
805-008-ARCR4NF18-55PA-72
SERIES 805 HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
Thermoplastic Polyurethane, Black, UL 94 V-0 Rated
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
BAND-IT® Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Stainless Steel
Up to 5 AMP Continuous Duty With #22 AWG Wire
500 VAC RMS sea level, 100 VAC RMS 70,000 feet
200 megohms minimum
Operating Temperature
Immersion
-30° C. to +105° C.
1 meter water immersion for 1 Hour per MIL-STD-810 Method 512 (IP68)
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
(8 Milliohms Mated Contacts) + (Wire Resistance)
50 dB minimum from 100MHz to 1000MHz.
K
L
Solvent Resistance, Polyamide Overmold
Electrical Resistance
Shielding Effectiveness
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
UL 94 V-0
Jacket Flammability and Toxicity
M
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com