D5015SS [GMI]
I.S. SIL2 2/4-Wire HART® Transmitter Power Supply;型号: | D5015SS |
厂家: | G.M. International |
描述: | I.S. SIL2 2/4-Wire HART® Transmitter Power Supply |
文件: | 总1页 (文件大小:276K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
www.gminternational.com
Intrinsically Safe Isolators > Analog Input
D5015
I.S. SIL2 2/4-Wire HART® Transmitter Power Supply
The Repeater Power Supply D5015 module is a high integrity analog input interface suitable for applications requiring SIL 2 level in safety
related systems for high risk industries. It provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA, active or passive,
transmitters located in Hazardous Area, and repeats the current in floating circuit to drive a Safe Area load. The circuit allows bi-directional
communication signals, for HART® devices.
FEATURES
TECHNICAL DATA
•
•
•
•
•
•
•
•
SIL 2 / SC 3 (pending)
Supply
Input from Zone 0 (pending)
Installation in Zone 2 (pending)
4-20 mAActive-Passive Input, Source-Sink Output
HART® compatible
Input and Output short circuit proof
High Accuracy
24 Vdc nom (18 to 30 Vdc), reverse polarity protected.
Current consumption: 50 mA (D5015SS), 40 mA (D5015SK), @ 24 Vdc
with 20 mA output, typical.
Power dissipation: 0.8 W (D5015SS), 1.0 W (D5015SK), @ 24 Vdc with
20 mA output, typical.
Input
Three port isolation, Input/Output/Supply
4 to 20 mA (separately powered input, voltage drop ≤ 0.5 V) or 4 to 20 mA
(2 wires Tx current limited ≈ 25 mA), reading range 0 to 24 mA.
Transmitter line voltage: 16.5 V minimum @ 20 mA.
Output
4 to 20 mA, on max. 600 Ω load in source mode; V min. 2 V @ 0 Ω load V
max. 30 V in sink mode (max. load resistance 600 Ω), current limited @ ≈
25 mA.
Response time: 5 ms.
Performance
FUNCTION DIAGRAM
Additional installation diagrams may be found in Instruction Manual.
Ref. Conditions: 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature.
Calibration accuracy: ≤ ± 20 µA.
Linearity accuracy: ≤ ± 10 µA.
Temp. influence: ≤ ± 2 µA/°C.
Isolation
Hazardous Area
Safe Area/Zone 2
I.S. In/Out 2.5 kV; I.S. In/Supply 2.5 kV; Out/Supply 500 V.
Environmental conditions
MODEL D5015SS
Operating temperature: temperature limits –40 to +70 °C.
Storage temperature: temperature limits –45 to +80 °C.
In
5 +
6 -
=
=
Supply 24 Vdc
HHT
Safety description
HHT
2 Wire Tx
External
Powered Tx
7
8
=
+
-
?
Associated apparatus and non-sparking electrical equipment.
Uo = 26.8 V, Io = 92 mA, Po = 614 mW at terminals 7-8.
Uo = 1.1 V, Io = 56 mA, Po = 16 mW at terminals 8-11.
Ui = 30 V, Ii = 128 mA, Ci = 0 nF, Li = 0 nH at terminals 8-11.
Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.
Source I
1
2
+
+
I
=
Out (SIL 2)
mA RL
11
=
-
-
Mounting
-
+
Termination
board
DIN-Rail 35 mm, with or without Power Bus or on custom Term. Board.
Weight: about 130 g.
Power Bus
connector
Connection: by polarized plug-in disconnect screw terminal blocks to
accommodate terminations up to 2.5 mm² (13 AWG).
Dimensions: Width 12.5 mm, Depth 123 mm, Height 120 mm.
MODEL D5015SK
In
5 +
6 -
=
=
Supply 24 Vdc
HHT
2 Wire Tx
?
External
Powered Tx
7
8
=
+
-
HHT
+
Sink I
1
2
+
RL
I
=
+
Out (SIL 2)
mA
11
=
-
-
-
+
Termination
board
connector
Power Bus
ORDERING INFORMATION
D5015SS: 1 channel source output
D5015SK: 1 channel sink output
Accessories
Bus Connector JDFT049, Bus Mounting Kit OPT5096.
Functional Safety Management Certification:
GM International is certified to conform to IEC61508:2010 part 1 clauses 5-6 for safety related systems up to and included SIL3. In addition, GM International products have been granted I.S. certificates from the most credited Notified Bodies in the world.
FSM
SIL 3
Data specified in this document are merely descriptive of the products and should be integrated with relevant technical specifications. Our products are in constant development and the information presented herein refers to the time of document issue.
No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. Terms & Conditions can be
found at our website. For more information refer to istruction manual.
DTS0629-5
© G.M. International s.r.l.
相关型号:
D501J11B202DQF
Rocker Switch, SPDT, Latched, Solder Terminal, Rocker Actuator, Through Hole-straight, ROHS COMPLIANT
ITT
D501J11B202HQA
Rocker Switch, SPDT, Latched, Solder Terminal, Rocker Actuator, Through Hole-straight, ROHS COMPLIANT
ITT
D501J11B202HQF
Rocker Switch, SPDT, Latched, Solder Terminal, Rocker Actuator, Through Hole-straight, ROHS COMPLIANT
ITT
D501J11B202NQA
Rocker Switch, SPDT, Latched, Solder Terminal, Rocker Actuator, Through Hole-straight, ROHS COMPLIANT
ITT
D501J11B202PQA
Rocker Switch, SPDT, Latched, Solder Terminal, Rocker Actuator, Through Hole-straight, ROHS COMPLIANT
ITT
D501J11B202QF
Rocker Switch, SPDT, Latched, Solder Terminal, Rocker Actuator, Through Hole-straight, ROHS COMPLIANT
ITT
D501J11B202RQF
Rocker Switch, SPDT, Latched, Solder Terminal, Rocker Actuator, Through Hole-straight, ROHS COMPLIANT
ITT