5-1  
Motor Control Device  
Motor protection circuit breaker  
E3VU series circuit breakers  
Application  
E3VU seriescircuitbreakersareapplicableforthecircuitofAC50/60Hz,ratedinsulationvoltage750V,ratedoperatingvoltageup  
to660V,ratedoperationcurrentfrom0.1Ato63A.Theyareusedforprotectingmotorsagainstoverload,short-circuitandphase-failure.They  
canalsobeusedforstartingandstoppingstartersformotors,andforthecircuitprotectioninthecircuitof0.1A-63A.  
Technical parameter  
Standard power ratings of Setting range of  
3-phase motors 50/60Hz thermal trips (A) current (A)  
in category AC-3 (kW)  
Magnetic tripping Thermal  
Reference  
Weight  
(kg)  
current Ie  
in (A)  
0.1-0.16  
0.16-0.24  
0.24-0.4  
0.4-0.6  
0.6-1  
1-1.6  
1.6-2.4  
2-3.2  
2.4-4  
3.2-5  
4-6  
1.9  
2.9  
4.8  
7.2  
12  
0.16  
0.24  
0.4  
0.6  
1
E3VU13-XB00  
E3VU13-XC00  
E3VU13-XD00  
E3VU13-XE00  
E3VU13-XF00  
E3VU13-XG00  
E3VU13-XH00  
E3VU13-NH00  
E3VU13-XJ00  
E3VU13-NJ00  
E3VU13-XK00  
E3VU13-NK00  
E3VU13-XL00  
E3VU13-NL00  
E3VU13-XM00  
E3VU13-XN00  
E3VU13-XP00  
E3VU16-XG00  
E3VU16-XH00  
E3VU16-XJ00  
E3VU16-XK00  
E3VU16-XL00  
E3VU16-XM00  
E3VU16-XN00  
E3VU16-XP00  
E3VU16-XQ00  
E3VU16-XR00  
E3VU16-KS00  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.29  
0.76  
0.76  
0.76  
0.76  
0.76  
0.76  
0.76  
0.76  
0.76  
0.76  
0.76  
0.06  
0.09/0.12  
0.12/0.18  
0.25  
E3VU13  
5
0.37/0.55  
0.75  
19  
1.6  
2.4  
3.2  
4
29  
1.1  
38  
1.1/1.5  
1.5/2.2  
2.2  
48  
60  
5
72  
6
3
5-8  
96  
8
6-10  
120  
156  
190  
240  
300  
19  
10  
13  
16  
20  
25  
1.6  
2.4  
4
4/5.5  
7.5  
8-13  
10-16  
14-20  
18-25  
1-1.6  
1.6-2.4  
2.4-4  
4-6  
7.5  
E3VU16  
11  
0.37/0.55  
0.75  
1.1/1.5  
2.2  
29  
48  
72  
6
3/4  
6-10  
120  
190  
300  
380  
480  
600  
600  
10  
16  
25  
32  
40  
52  
63  
5.5/7.5  
11  
10-16  
16-25  
22-32  
28-40  
36-52  
45-63  
15  
18.5  
22  
No auxiliary contacts: 0  
WithauxiliarycontactsIntegratedinthecircuit-breaker:1NO+1NC 1, 2NO 2,2NC  
3
Greegoo Electric 11.2007  
5-2  
Motor Control Device  
Motor protection circuit breaker  
E3VE series circuit breakers  
Application  
E3VE seriescircuitbreakersaresuitableinthecircuitofAC50/60Hz,ratedoperatingvoltageupto660V,ratedoperatingcurrent  
from0.1Ato63A.Theyareusedforpreventingmotorsfromoverloadandshortcircuit.Theyalsocanbeusedasdirectstarterstostartmotors  
andswitchestochangeoverthecircuitunderthenormalconditions.  
Technical parameter  
Rated breaking capacity of short circuit Rated  
Rated  
Mechanic  
life  
Electric  
life  
Reference  
voltage (V) current (A)  
220V  
380V  
660V  
4x104  
4x104  
2x104  
1.5  
10  
1.5  
10  
1
660  
660  
660  
20  
32  
63  
5000  
5000  
1500  
E3VE1  
E3VE3  
E3VE4  
3
22  
22  
7.5  
Setting range of  
thermal trips (A)  
Thermal current  
Ie in (A)  
Reference  
Type  
E3VE1  
0.1-0.16  
0.16-0.25  
0.25-0.4  
0.16  
0.25  
0.4  
E3VE1-1B00  
E3VE1-1C00  
E3VE1-1D00  
5
0.4-0.63  
0.63-1  
1-1.6  
0.63  
1
E3VE1-1E00  
E3VE1-1F00  
E3VE1-1G00  
E3VE1-1H00  
E3VE1-1S00  
E3VE1-1J00  
E3VE1-1T00  
E3VE1-1K00  
E3VE1-1Z00  
E3VE1-1L00  
1.6  
2.5  
3.2  
4
1.6-2.5  
2-3.2  
E3VE1  
2.5-4  
3.2-4.5  
4-6.3  
4.5  
6.3  
8
5-8  
6.3-10  
10  
8-12.5  
10-16  
14-20  
1-1.6  
12.5  
16  
E3VE1-1X00  
E3VE1-1M00  
E3VE1-1N00  
E3VE3-1G00  
E3VE3-1H00  
20  
0.16  
0.25  
1.6-2.5  
2.5-4  
0.4  
0.63  
10  
E3VE3-1J00  
E3VE3-1K00  
E3VE3-1L00  
E3VE3-1X00  
E3VE3-1M00  
E3VE3-1Y00  
4-6.3  
E3VE3  
6.3-10  
8-12.5  
10-16  
12.5-20  
12.5  
16  
20  
16-25  
22-32  
25  
32  
E3VE3-1N00  
E3VE3-1P00  
E3VE3  
6.3-10  
10-16  
16-25  
22-32  
28-40  
36-50  
45-63  
6.3-10  
10-16  
10  
16  
25  
32  
40  
50  
63  
10  
16  
E3VE3-1L00  
E3VE3-1M00  
E3VE3-1N00  
E3VE3-1P00  
E3VE3-1S00  
E3VE3-1R00  
E3VE3-1T00  
E3VE4-1L00  
E3VE4-1M00  
16-25  
22-32  
28-40  
36-50  
45-63  
25  
32  
40  
50  
63  
E3VE4-1N00  
E3VE4-1P00  
E3VE4-1S00  
E3VE4-1R00  
E3VE4-1T00  
E3VE4  
E3VE4  
Greegoo Electric 11.2007  
5-3  
Motor Control Device  
Motor protection circuit breaker  
EGV2-M series circuit breakers  
Application  
EGV2-M series circuit breakers are mainly used for the overload and short-circuit protection for motors in the  
circuit of AC 50/60Hz, rated operating voltage up to 660V, rated operating current from 0.1A to 80A, as the full-  
voltage starters to start and cut off motors under the AC3 load, and for the circuit protection in the circuit of  
0.1A-80A.  
Technical parameter  
Standard power ratings of 3-phase motors 50/60Hz in Setting range Magnetic  
Thermal Reference Weight  
category AC-3  
of thermal  
trips (A)  
tripping  
current  
Ie in  
(kg)  
current (A)  
220V  
2 3 0 V  
(kW)  
400V  
4 1 5 V  
(kW)  
440V  
(kW)  
550V  
(kW)  
690V  
(kW)  
(A)  
-
-
-
-
-
0.1-0.16  
0.16-0.25  
0.25-0.40  
0.40-0.63  
0.63-1  
1-1.6  
1.5  
2.4  
5
0.16  
0.25  
0.40  
0.63  
1
EGV2-M01  
EGV2-M02  
EGV2-M03  
EGV2-M04  
EGV2-M05  
EGV2-M06  
EGV2-M07  
EGV2-M08  
EGV2-M10  
EGV2-M14  
EGV2-M16  
EGV2-M20  
EGV2-M21  
EGV2-M22  
EGV2-M32  
0.260  
0.260  
0.260  
0.260  
0.260  
0.260  
0.260  
0.260  
0.260  
0.260  
0.260  
0.260  
0.260  
0.260  
0.260  
-
0.06  
0.09  
0.12  
0.25  
0.37  
0.75  
1.1  
0.06  
0.09  
0.18  
0.25  
0.37  
0.75  
1.5  
2.2  
4
-
-
0.06  
-
-
-
-
0.37  
0.55  
0.75  
1.5  
2.2  
4
8
5
0.09  
0.18  
0.37  
0.55  
1.1  
1.5  
2.2  
4
0.37  
0.37  
1.1  
1.5  
3
13  
EGV2-M  
22.5  
33.5  
51  
1.6  
2.5  
4
1.6-2.5  
2.5-4  
2.2  
4-6.3  
78  
6.3  
9
3
4
5.5  
9
6-10  
138  
170  
223  
327  
327  
416  
5.5  
7.5  
9
5.5  
7.5  
11  
7.5  
9
9-14  
13  
15  
13-18  
17  
5.5  
5.5  
7.5  
11  
15  
18.5  
18.5  
22  
17-23  
21  
11  
11  
20-25  
23  
15  
15  
22  
24-32  
30  
Thermal-magneticmotorcircuit-breakersEGV2-Mwithbuilt-inauxiliarycontactblock  
D i m e n s i o n  
Greegoo Electric 11.2007  
5-4  
Motor Control Device  
Motor protection circuit breaker  
EGV2-ME series circuit breakers  
Application  
EGV2-ME series circuit breakers are mainly used for the overload and short-circuit protection for motors in the  
circuit of AC 50/60Hz, rated operating voltage up to 660V, rated operating current from 0.1A to 80A, as the  
full-voltage starters to start and cut off motors under the AC3 load, and for the circuit protection in the circuit  
of 0.1A-80A.  
Technical parameter  
Standard power ratings of 3-phase motors 50/60Hz in Setting range Magnetic  
Thermal Reference Weight  
category AC-3  
of thermal  
trips (A)  
tripping  
current  
Ie in  
(kg)  
current (A)  
220V  
230V  
(kW)  
400V  
415V  
(kW)  
440V  
(kW)  
550V  
(kW)  
690V  
(kW)  
(A)  
-
-
-
-
-
0.1-0.16  
0.16-0.25  
0.25-0.40  
0.40-0.63  
0.63-1  
1-1.6  
1.5  
2.4  
5
0.16  
0.25  
0.40  
0.63  
1
EGV2-ME01 0.260  
EGV2-ME02 0.260  
EGV2-ME03 0.260  
EGV2-ME04 0.260  
EGV2-ME05 0.260  
EGV2-ME06 0.260  
EGV2-ME07 0.260  
EGV2-ME08 0.260  
EGV2-ME10 0.260  
EGV2-ME14 0.260  
EGV2-ME16 0.260  
EGV2-ME20 0.260  
EGV2-ME21 0.260  
EGV2-ME22 0.260  
EGV2-ME32 0.260  
-
0.06  
0.09  
0.12  
0.25  
0.37  
0.75  
1.1  
2.2  
0.06  
0.09  
0.18  
0.25  
0.37  
0.75  
1.5  
2.2  
4
-
-
0.06  
-
-
-
5
-
0.37  
0.55  
0.75  
1.5  
2.2  
4
8
0.09  
0.18  
0.37  
0.55  
1.1  
1.5  
2.2  
4
0.37  
0.37  
1.1  
1.5  
3
13  
EGV2-ME  
22.5  
33.5  
51  
1.6  
2.5  
4
1.6-2.5  
2.5-4  
4-6.3  
78  
6.3  
9
3
4
5.5  
9
6-10  
138  
170  
223  
327  
327  
416  
5.5  
7.5  
9
5.5  
7.5  
11  
7.5  
9
9-14  
13  
15  
13-18  
17  
5.5  
5.5  
7.5  
11  
15  
18.5  
18.5  
22  
17-23  
21  
11  
11  
20-25  
23  
15  
15  
22  
24-32  
30  
Thermal-magneticmotorcircuit-breakers EGV2-MEwithbuilt-inauxiliarycontactblock  
Dimension  
Greegoo Electric 11.2007  
5-5  
Motor Control Device  
Motor protection circuit breaker  
EGV2-RS series circuit breakers  
Application  
EGV2-RSseriescircuitbreakersaremainlyusedfortheoverloadandshort-circuitprotectionformotorsinthecircuitofAC50/60Hz,rated  
operatingvoltageupto660V,ratedoperatingcurrentfrom0.1Ato80A,asthefull-voltagestarterstostartandcutoffmotorsundertheAC3  
load,andforthecircuitprotectioninthecircuitof0.1A-80A.  
Technical parameter  
Standard power ratings of 3-phase motors 50/60Hz Setting range Magnetic  
Thermal Reference Weight  
in category AC-3  
of thermal  
trips (A)  
tripping  
current  
Ie in  
(kg)  
current (A)  
220V  
230V  
(kW)  
400V  
415V  
(kW)  
440V  
(kW)  
550V  
(kW)  
690V  
(kW)  
(A)  
-
-
-
-
-
0.1-0.16  
0.16-0.25  
0.25-0.40  
0.40-0.63  
0.63-1  
1-1.6  
1.5  
2.4  
5
0.16  
0.25  
0.40  
0.63  
1
EGV2-RS01 0.260  
EGV2-RS02 0.260  
EGV2-RS03 0.260  
EGV2-RS04 0.260  
EGV2-RS05 0.260  
EGV2-RS06 0.260  
EGV2-RS07 0.260  
EGV2-RS08 0.260  
EGV2-RS10 0.260  
EGV2-RS14 0.260  
EGV2-RS16 0.260  
EGV2-RS20 0.260  
EGV2-RS21 0.260  
EGV2-RS22 0.260  
EGV2-RS32 0.260  
-
0.06  
0.09  
0.12  
0.25  
0.37  
0.75  
1.1  
2.2  
0.06  
0.09  
0.18  
0.25  
0.37  
0.75  
1.5  
2.2  
4
-
-
0.06  
-
-
-
5
-
0.37  
0.55  
0.75  
1.5  
2.2  
4
8
EGV2-RS  
0.09  
0.18  
0.37  
0.55  
1.1  
1.5  
2.2  
4
0.37  
0.37  
1.1  
1.5  
3
13  
22.5  
33.5  
51  
1.6  
2.5  
4
1.6-2.5  
2.5-4  
4-6.3  
78  
6.3  
9
3
4
5.5  
9
6-10  
138  
170  
223  
327  
327  
416  
5.5  
7.5  
9
5.5  
7.5  
11  
7.5  
9
9-14  
13  
15  
13-18  
17  
5.5  
5.5  
7.5  
11  
15  
18.5  
18.5  
22  
17-23  
21  
11  
11  
20-25  
23  
15  
15  
22  
24-32  
30  
Thermal-magneticmotorcircuit-breakers EGV2-RSwithbuilt-inauxiliarycontactblock  
Dimension  
Greegoo Electric 11.2007  
5-6  
Motor Control Device  
Motor protection circuit breaker  
EGV3-M series circuit breakers  
Technical parameter  
Standard power ratings of Setting range of Magnetic tripping Thermal  
Reference  
3-phase motors 50/60Hz thermal trips (A)  
in category AC-3 (kW)  
current (A)  
current Ie  
in (A)  
0.37  
0.75  
1.1/1.5  
2.2  
1-1.6  
1.6-2.5  
2.5-4  
4-6  
19  
1.6  
2.5  
4
EGV3-M06  
EGV3-M07  
EGV3-M08  
EGV3-M10  
EGV3-M14  
EGV3-M20  
EGV3-M25  
EGV3-M40  
EGV3-M63  
EGV3-M80  
30  
48  
72  
6
3/4  
6-10  
120  
190  
300  
480  
720  
960  
10  
16  
25  
40  
63  
80  
5.5/7.5  
11  
10-16  
16-25  
25-40  
40-63  
56-80  
18.5  
30  
5
EGV3-M  
40  
EGV3-ME series circuit breakers  
Technical parameter  
Standard power ratings of Setting range of Magnetic tripping Thermal  
Reference  
3-phase motors 50/60Hz thermal trips (A)  
in category AC-3 (kW)  
current (A)  
current Ie  
in (A)  
0.37  
0.75  
1.1/1.5  
2.2  
1-1.6  
1.6-2.5  
2.5-4  
4-6  
19  
1.6  
2.5  
4
EGV3-ME06  
EGV3-ME07  
EGV3-ME08  
EGV3-ME10  
EGV3-ME14  
EGV3-ME20  
EGV3-ME25  
EGV3-ME40  
EGV3-ME63  
EGV3-ME80  
30  
48  
72  
6
3/4  
6-10  
120  
190  
300  
480  
720  
960  
10  
16  
25  
40  
63  
80  
5.5/7.5  
11  
10-16  
16-25  
25-40  
40-63  
56-80  
18.5  
30  
EGV3-ME  
40  
D i m e n s i o n  
Greegoo Electric 11.2007  
5-7  
Motor Control Device  
Motor protection circuit breaker  
EGV4-M series circuit breakers box  
Technical parameter  
Standard power ratings of 3-phase motors 50/60Hz Setting range Magnetic  
Thermal Reference Weight  
in category AC-3  
of thermal  
trips (A)  
tripping  
current  
Ie in  
(kg)  
current (A)  
220V  
230V  
(kW)  
400V  
415V  
(kW)  
440V  
(kW)  
550V  
(kW)  
690V  
(kW)  
(A)  
-
-
-
-
-
0.1-0.16  
0.16-0.25  
0.25-0.40  
0.40-0.63  
0.63-1  
1-1.6  
1.5  
2.4  
5
0.16  
0.25  
0.40  
0.63  
1
EGV4-M01 0.260  
EGV4-M02 0.260  
EGV4-M03 0.260  
EGV4-M04 0.260  
EGV4-M05 0.260  
EGV4-M06 0.260  
EGV4-M07 0.260  
EGV4-M08 0.260  
EGV4-M10 0.260  
EGV4-M14 0.260  
EGV4-M16 0.260  
EGV4-M20 0.260  
EGV4-M21 0.260  
EGV4-M22 0.260  
EGV4-M32 0.260  
-
0.06  
0.09  
0.12  
0.25  
0.37  
0.75  
1.1  
2.2  
0.06  
0.09  
0.18  
0.25  
0.37  
0.75  
1.5  
2.2  
4
-
-
0.06  
-
-
-
-
0.37  
0.55  
0.75  
1.5  
2.2  
4
8
0.09  
0.18  
0.37  
0.55  
1.1  
1.5  
2.2  
4
0.37  
0.37  
1.1  
1.5  
3
13  
22.5  
33.5  
51  
1.6  
2.5  
4
1.6-2.5  
2.5-4  
5
EGV4-M  
4-6.3  
78  
6.3  
9
3
4
5.5  
9
6-10  
138  
170  
223  
327  
327  
416  
5.5  
7.5  
9
5.5  
7.5  
11  
7.5  
9
9-14  
13  
15  
13-18  
17  
5.5  
5.5  
7.5  
11  
15  
18.5  
18.5  
22  
17-23  
21  
11  
11  
20-25  
23  
15  
15  
22  
24-32  
30  
Thermal-magnetic motor circuit-breakers EGV4-M with built-in auxiliary contact block  
EGV4-ME series circuit breakers box  
Technical parameter  
Standard power ratings of 3-phase motors 50/60Hz Setting range Magnetic  
Thermal Reference Weight  
in category AC-3  
of thermal  
trips(A)  
tripping  
current  
Ie in  
(kg)  
current (A)  
220V  
230V  
(kW)  
400V  
415V  
(kW)  
440V  
(kW)  
550V  
(kW)  
690V  
(kW)  
(A)  
-
-
-
-
-
0.1-0.16  
0.16-0.25  
0.25-0.40  
0.40-0.63  
0.63-1  
1-1.6  
1.5  
2.4  
0.16  
0.25  
0.40  
0.63  
1
EGV4-ME01 0.260  
EGV4-ME02 0.260  
EGV4-ME03 0.260  
EGV4-ME04 0.260  
EGV4-ME05 0.260  
EGV4-ME06 0.260  
EGV4-ME07 0.260  
EGV4-ME08 0.260  
EGV4-ME10 0.260  
EGV4-ME14 0.260  
EGV4-ME16 0.260  
EGV4-ME20 0.260  
EGV4-ME21 0.260  
EGV4-ME22 0.260  
EGV4-ME32 0.260  
-
0.06  
0.09  
0.12  
0.25  
0.37  
0.75  
1.1  
2.2  
0.06  
0.09  
0.18  
0.25  
0.37  
0.75  
1.5  
2.2  
4
-
-
0.06  
-
-
-
5
-
0.37  
0.55  
0.75  
1.5  
2.2  
4
8
0.09  
0.18  
0.37  
0.55  
1.1  
1.5  
2.2  
4
0.37  
0.37  
1.1  
1.5  
3
13  
EGV4-ME  
22.5  
33.5  
51  
1.6  
2.5  
4
1.6-2.5  
2.5-4  
4-6.3  
78  
6.3  
9
3
4
5.5  
9
6-10  
138  
170  
223  
327  
327  
416  
5.5  
7.5  
9
5.5  
7.5  
11  
7.5  
9
9-14  
13  
15  
13-18  
17  
5.5  
5.5  
7.5  
11  
15  
18.5  
18.5  
22  
17-23  
21  
11  
11  
20-25  
23  
15  
15  
22  
24-32  
30  
Thermal-magnetic motor circuit-breakers EGV4-ME with built-in auxiliary contact block  
Greegoo Electric 11.2007  
5-8  
Motor Control Device  
Motor protection circuit breaker  
EDZMO motor protective circuit breaker  
Application  
EDZMO Motor Protective Circuit Breaker is applicable for the circuit of Ac 50/60Hz, rated insulation voltage  
750V, rated operating voltage up to 660V, rated operating current from 0.1A to 25A. It is used for protecting  
the motor against overload, short-circuit and phase-failure, It can be also used for starting and breaking the  
starter of motor and for the circuit protection in the circuit of 25A.  
Switching capacity 150/50KA/415V  
Short-circuit release, fixed setting to 14X Iu  
Single-phasing sensitive  
With screws or spring loaded terminals  
Comply with IEC/EN60947  
Technical parameter  
Standard power ratings of Setting range of  
3-phase motors 50/60Hz in thermal trips (A)  
category AC-3 (kW)  
Norminal breaking  
capacity (A)  
Thermal current Reference  
Ie in (A)  
-
0.1-0.16  
0.16-0.25  
0.25-0.4  
0.4-0.63  
0.63-1  
1-1.6  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
50  
0.16  
0.25  
0.4  
0.63  
1
EDZM0-01  
EDZM0-02  
EDZM0-03  
EDZM0-04  
EDZM0-05  
EDZM0-06  
EDZM0-07  
EDZM0-08  
EDZM0-10  
EDZM0-14  
EDZM0-16  
EDZM0-20  
EDZM0-21  
EDZM0-22  
EDZM0-32  
5
0.06  
0.09  
0.12  
0.25  
0.55  
0.75  
1.5  
2.2  
3
EDZM0  
1.6  
2.5  
4
1.6-2.5  
2.5-4  
4-6.3  
6.3  
6.6  
10  
6.3-10  
6.3-10  
10-16  
4
5.5  
7.5  
9
16  
10-16  
50  
16  
16-20  
50  
20  
12.5  
20-25  
50  
25  
Greegoo Electric 11.2007  
5-9  
Motor Control Device  
Motor protection circuit breaker  
E3RV series circuit breakers  
Application  
E3RV seriescircuitbreakersaremainlyusedfortheoverload,short-circuitandphase-failureprotectionformotorsinthecircuitof  
AC50/60Hz,ratedoperatingvoltageupto660V,ratedoperatingcurrentfrom0.11Ato25A.Theycanbealsousedforcircuitprotection  
in the circuit of 0.11A-25A.  
Standard power ratings of Setting range Magnetic  
Thermal  
current  
current (A) Ie in (A)  
Short circuit breaking Reference  
capacity under the  
3-phase motors 50/60Hz  
in category AC-3 (kW)  
of thermal  
trips (A)  
tripping  
condition of AC 400V  
0.04  
0.06  
0.06  
0.09  
0.09  
0.12  
0.18  
0.18  
0.25  
0.37  
0.55  
0.75  
0.75  
1.1  
0.11-0.16  
0.14-0.2  
0.18-0.25  
0.22-0.32  
0.28-0.4  
0.35-0.5  
0.45-0.63  
0.55-0.8  
0.7-1  
2.1  
2.6  
3.3  
4.2  
5.2  
6.5  
8.2  
10  
0.16  
0.2  
0.25  
0.32  
0.4  
0.5  
0.63  
0.8  
1
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
50  
E3RV10 11-0AA1.  
E3RV10 11-0BA1.  
E3RV10 11-0CA1.  
E3RV10 11-0DA1.  
E3RV10 11-0EA1.  
E3RV10 11-0FA1.  
E3RV10 11-0GA1.  
E3RV10 11-0HA1.  
E3RV10 11-0JA1.  
E3RV10 11-0KA1.  
E3RV10 11-1AA1.  
E3RV10 11-1BA1.  
E3RV10 11-1CA1.  
E3RV10 11-1DA1.  
E3RV10 11-1EA1.  
E3RV10 11-1FA1.  
E3RV10 11-1GA1.  
E3RV10 11-1HA1.  
E3RV10 11-1JA1.  
E3RV10 11-1KA1.  
E3RV10 21-0AA1.  
E3RV10 21-0BA1.  
E3RV10 21-0CA1.  
E3RV10 21-0DA1.  
E3RV10 21-0EA1.  
E3RV10 21-0FA1.  
E3RV10 21-0GA1.  
E3RV10 21-0HA1.  
E3RV10 21-0JA1.  
E3RV10 21-0KA1.  
E3RV10 21-1AA1.  
E3RV10 21-1BA1.  
E3RV10 21-1CA1.  
E3RV10 21-1DA1.  
E3RV10 21-1EA1.  
E3RV10 21-1FA1.  
E3RV10 21-1GA1.  
E3RV10 21-1HA1.  
E3RV10-11  
5
13  
0.9-1.25  
1.1-1.6  
1.4-2  
16  
1.25  
1.6  
2
21  
26  
1.8-2.5  
2.2-3.2  
2.8-4  
33  
2.5  
3.2  
4
42  
1.5  
52  
1.5  
3.5-5  
65  
5
2.2  
4.5-6.3  
5.5-8  
82  
6.3  
8
3
104  
130  
156  
2.1  
2.6  
3.3  
4.2  
5.2  
6.5  
8.2  
10  
E3RV10-21  
4
7-10  
10  
50  
5.5  
9-12  
12  
50  
0.04  
0.06  
0.06  
0.09  
0.09  
0.12  
0.18  
0.18  
0.25  
0.37  
0.55  
0.75  
0.75  
1.1  
0.11-0.16  
0.14-0.2  
0.18-0.25  
0.22-0.32  
0.28-0.4  
0.35-0.5  
0.45-0.63  
0.55-0.8  
0.7-1  
0.16  
0.2  
0.25  
0.32  
0.4  
0.5  
0.63  
0.8  
1
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
13  
0.9-1.25  
1.1-1.6  
1.4-2  
16  
1.25  
1.6  
2
21  
26  
1.8-2.5  
2.2-3.2  
2.8-4  
33  
2.5  
3.2  
4
42  
1.5  
52  
1.5  
3.5-5  
65  
5
2.2  
4.5-6.3  
5.5-8  
82  
6.3  
8
3
104  
Greegoo Electric 11.2007  
5-10  
Motor Control Device  
Motor protection circuit breaker  
Standard power ratings of Setting range of Magnetic tripping Thermal Short circuit beraking  
Reference  
3-phase motors 50/60Hz in thermal trips (A) current (A)  
category AC-3 (kW)  
current Ie capacity under the  
in (A)  
condition of AC 400V  
4
7-10  
130  
163  
208  
260  
286  
325  
10  
100  
100  
50  
E3RV10 21-1JA1  
E3RV10 21-1KA1  
E3RV10 21-4AA1  
E3RV10 21-4BA1  
E3RV10 21-4CA1  
E3RV10 21-4DA1  
5.5  
7.5  
7.5  
11  
11  
9-12.5  
11-16  
14-20  
17-22  
20-25  
12.5  
16  
20  
50  
22  
50  
25  
50  
Therecommendeddataforfour-phasestandardelectromotorundertheconditionofAC50Hz,400V.Whataffectstheproductmostisthe  
factualstartingdataandrateddataoftheprotectedelectomotor.  
D i m e n s i o n  
5
E3RV10-11  
E3RV10-21  
1.2-polesidesupplementaryswitch;  
2.Signalswitchor4-polesidesupplementaryswitch;  
3.Supplementaryreleaser;  
4.Transversesupplementarycontact;  
5. Patching slice for screw installation;  
6.Punchingtemplate;  
7.35mmstandardinstallationguideway;  
8. Lockthelocationofbreakingthediameterofthestapleis3.5mmor4.5mm.  
Greegoo Electric 11.2007  

相关型号:

EGV2-ME

Motor protection circuit breaker
GREEGOO

EGV2-RS

Motor protection circuit breaker
GREEGOO

EGVD250ELL622MM30H

MINIATURE ALUMINUM ELECTROLYTIC CAPACITORS
CHEMI-CON

EGVD250ELL822MMP1H

MINIATURE ALUMINUM ELECTROLYTIC CAPACITORS
CHEMI-CON

EGW-1

Wirewound Resistors, Military/Established Reliability
VISHAY

EGW-10

Wirewound Resistors, Military/Established Reliability
VISHAY

EGW-2

Wirewound Resistors, Military/Established Reliability
VISHAY

EGW-3

Wirewound Resistors, Military/Established Reliability
VISHAY

EGW.5M.114.XLM

CONN RCPT FMALE 114POS CRIMP
ETC

EGW.LM.U2A.XPL

CONN USB A PNL MT THREADED IP68
ETC

EGW.LM.U2A.XPP

CONN USB ADAPTER A/A PNL MT
ETC

EGW0119R10BB1280

Fixed Resistor, Wire Wound, 1W, 19.1ohm, 0.1% +/-Tol, -20,20ppm/Cel,
VISHAY