59052-X-V-01-C

更新时间:2024-09-18 08:07:08
品牌:HAMLIN
描述:Firecracker Features and Benefits

59052-X-V-01-C 概述

Firecracker Features and Benefits 鞭炮特点和优点

59052-X-V-01-C 数据手册

通过下载59052-X-V-01-C数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
www.hamlin.com  
File E61760(N)  
Actuator  
59025 Firecracker Features and Benefits  
Features  
Benefits  
Applications  
2 part magnetically operated  
proximity sensor  
UL recognised  
Choice of normally open, normally  
closed or change over contacts  
Customer defined sensitivity  
Choice of cable length and  
connector  
Quick and easy to install  
No standby power requirement  
Operates through non-ferrous  
materials such as wood, plastic or  
aluminium  
Hermetically sealed, magnetically  
operated contacts continue to  
operate long after optical and other  
technologies fail due to  
Position and limit sensing  
Security  
Level sensing  
Linear actuators  
Sensor  
contamination  
DIMENSIONS (in) mm  
B
Max  
C
NOM.  
A
Max  
57025  
59025  
(.245) 6,22  
(.245) 6,22  
(1.000) 25,40  
(1.000) 25,40  
-
Table 3 ± (.393) 10,00  
CUSTOMER OPTIONS - Switching Specifications  
TABLE 1  
ContactType  
Form A  
Normally  
Open  
Normally Open  
HighVoltage  
Change  
Over  
Normally  
Closed  
Switch Type  
1
2
3
4
Power  
Watt - max.  
Vdc - max.  
Vdc - min.  
A - max.  
A - max.  
- max.  
- min.  
pF - typ.  
°C  
10  
10  
5
5
Voltage  
Switching  
Breakdown  
Switching  
Carry  
200  
300  
175  
175  
250  
450  
200  
200  
Current  
0.5  
0.5  
0.25  
0.25  
1.2  
1.5  
1.5  
1.5  
Resistance  
Contact, Initial  
Insulation  
Contact  
0.2  
1010  
0.2  
1010  
0.2  
109  
0.2  
109  
Capacitance  
Temperature  
0.3  
-40 to +105  
-65 to +105  
1.0  
0.2  
-20 to +105  
-65 to +105  
1.0  
0.3  
0.3  
Operating  
Storage  
-40 to +105  
-40 to +105  
°C  
-65 to +105  
-65 to +105  
Time  
Operate  
ms - max.  
ms - max.  
G - max.  
3.0  
3.0  
50  
3.0  
3.0  
50  
Release  
1.0  
1.0  
Shock  
11ms 1⁄2 sine  
50-2000 Hz  
100  
100  
Vibration  
G
- max.  
30  
30  
30  
30  
CUSTOMER OPTIONS - Sensitivity, Cable Length andTermination Specification  
TABLE 2  
TABLE 3  
TABLE 4  
Termination Options:-  
Sensitivity Options:-  
CableType:-  
Activate Distances are approximate  
using Hamlin 57025 actuator  
as illustrated  
24 AWG 7/32 PVC 105oC  
UL1430/UL1569  
SELECT  
OPTION  
DESCRIPTION  
(2 WIRE VERSIONS ILLUSTRATED)  
Standard Lengths  
SELECT  
OPTION  
Switch AT before modification  
A or F Tinned or untinned leads  
CABLE  
LENGTH  
(in) mm  
C
D
E
6.35mm fastons  
Select Option  
S
T
U
V
Switch  
Activate  
Distance  
d
Activate  
Distance  
d
Activate  
Activate  
Distance  
d
01  
02  
03  
04  
05  
(3,94) 100  
(11,81) 300  
(19,69) 500  
(29,53) 750  
(39,37) 1000  
Pull In  
AT  
Pull In  
AT  
Pull In  
AT  
Pull In  
AT  
Type  
Distance  
d
Range  
Range  
Range  
Range  
(in) mm  
(in) mm  
(in) mm  
(in) mm  
1
2
3
4
Normally Open  
High Voltage  
12-18  
(.315)  
8.0  
(.236)  
6.0  
(.197)  
5.0  
(.157)  
4.0  
AMP MTE 2.54mm pitch  
JST XHP 2.5mm pitch  
17-23  
20-25  
22-28  
25-30  
27-33  
Change Over  
Normally Closed  
(.276)  
7.0  
(.216)  
5.5  
(.177)  
4.5  
15-20  
ORDERING INFORMATION  
N.B. 57025 actuator sold separately  
59025
X
X
XX  
X
Series 59025  
SwitchType  
Sensitivity  
Table 1  
Table 2  
Table 3  
Cable Length  
Termination  
Table 4  
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR  
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED  
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.  
Product performance may be affected by the application to which the  
product is put. Upon request, HAMLIN will assist purchasers by  
providing information specific to any particular application. HAMLIN  
disclaims any and all liability whatsoever for any purchasers reliance  
upon the information contained on this data sheet without further  
consultation with authorised representatives of HAMLIN.  
Hamlin USA  
Hamlin UK  
Tel: +1 920 648 3000 Fax: +1 920 648 3001 Email: sales.us@hamlin.com  
Tel: +44 (0)1379 649700 Fax: +44 (0)1379 649702 Email: sales.uk@hamlin.com  
Hamlin Germany Tel: +49 (0) 6181 953660 Fax: +49 (0) 6181 9536666 Email: sales.de@hamlin.com  
Hamectrol France Tel: +33 (0) 1 4687 0202 Fax: +33 (0) 1 4686 6786 Email: sales.fr@hamlin.com  
ISSUE No: 4 DATE: 1/5/3  
22  

59052-X-V-01-C 相关器件

型号 制造商 描述 价格 文档
59052-X-V-01-D HAMLIN Firecracker Features and Benefits 获取价格
59052-X-V-01-E HAMLIN Firecracker Features and Benefits 获取价格
59052-X-V-02-A HAMLIN Firecracker Features and Benefits 获取价格
59052-X-V-02-C HAMLIN Firecracker Features and Benefits 获取价格
59052-X-V-02-D HAMLIN Firecracker Features and Benefits 获取价格
59052-X-V-02-E HAMLIN Firecracker Features and Benefits 获取价格
59052-X-V-03-A HAMLIN Firecracker Features and Benefits 获取价格
59052-X-V-03-C HAMLIN Firecracker Features and Benefits 获取价格
59052-X-V-03-D HAMLIN Firecracker Features and Benefits 获取价格
59052-X-V-03-E HAMLIN Firecracker Features and Benefits 获取价格

59052-X-V-01-C 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    6
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    9
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6