HDRC255P-110J-490 [HITRON]
310W 3U X 8HP CPCI Package;型号: | HDRC255P-110J-490 |
厂家: | HITRON ELECTRONICS CORPORTION |
描述: | 310W 3U X 8HP CPCI Package PC |
文件: | 总2页 (文件大小:249K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
H HiTRON
16.6-160VDC Input Range DC-DC Converter Hot-Swap CompactPCI
Quad Output 310 Watts Railway Switching Power Supplies
HDRC255P-110J-490(E) Series
Features
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
310W 3U X 8HP CPCI Package
16.6-160VDC 10:1 Wide Input Range
Meet EN50155 Class S2 & C2 compliance
Suitable for CPCI Express Application
Wide Operating Temp. -40°C t +85°C
N+1 Redundancy/Hot-Swappable
Using 125°C Long Life Solid Capacitors
CE Marking Level 3 Compliance
Specification
Input
General
Input Voltage
16.6-160VDC, nominal 110VDC
Efficiency
(120W) Typical 85% at 24VDC
(310W)
Input Current (F-L/120W) 6A at 24VDC 1.3A at 110VDC
88% at 48VDC & 89% at 110VDC
120KHz at nominal I/P 110VDC
I/P-O/P: 3000VAC I/P-GND:1500VAC
O/P-GND:1000VAC
(F-L/310W)
7.5A at 48VDC, 3.3A at 110VDC
Switching Frequency
Dielectric Withstand
(No-Load)
0.35A at 24VDC, 0.45A at 110VDC
Soft Star
Installed
Inrush Current
Input Connector
Peak 27A at nominal 110VDC
Positronic 47-pin PCIH47M400A1 Transient Response
Circuit Topology
Resonant Forward circuit
Peak transient < 300mV & recovers
within 3mS for 25% load-change
Output
Output Connector
Line Regulation
Load Regulation
Positronic 47-pin PCIH47M400A1 Remote ON/OFF
Available at [INH#] & [EN#] pins
Available at [FAL#] pin
Typical 0.2%
V1/V2 typical ±1%,
Power Fail Signal
Power OK Signal
Status LED
Available for all outputs
<Green> means valid input voltage
<Red> means a critical fault
Internal OR-ing diodes
Available
V3 typical ±2% V4 typical ±5%
Typical 1% Peak-Peak
Available at V1,V2 & V3
Available at V1, V2 & V3
Available at V1, V2 & V3
Noise & Ripple
Remote Sense
Adjustability
N+1 Redundancy
Hot-Swappable
Power Density
Current Sharing
2.2-5.5 Watts/Cubic Inch
Output Trim
Available at V1/2[ADJ #]
Environmental
Operating Temperature
-40 °C to +85 °C with de-rating
Protection
Over Voltage
Over Current
Over Load
Built-in at all outputs
Installed in each rail.
Typical 120% max. load
Storage Temperature
Cooling
-45°C to +90°C
150-310W:400-600LFM moving air
90-120W:Convection air (Fanless)
fully protected against output
Safety/EMC
Emissions (conducted)
Safety Standard
CE Standard
overload or short circuit
Installed NTC for thermal sensor
at [DEG#] pin
CISPR EN55032 Class A
IEC60950-1 Class I
Over Temperature
Meet Level 3 Criteria A
Six degree-of-freedom random
10Hz-150Hz, 10G
Input-Under &
Over-Voltage
Installed
Vibration
Input Reverse Voltage Installed
Radiated Susceptibility
Surge
EN61000-4-3 Level X (20V/m)
Conformal Coating
Available
EN61000-4-5 Level 3, L-L 2KV,L-G 2KV
Conducted Disturbance
EN61000-4-6 Level X (20V/m)
Notes:
(1) All measurement are at nominal input, full load and +25°C unless otherwise specifications.
(2) Due to requests in market and advances in technology, specifications subject to change without notification.
(3) A warm-up time 10 minutes is required after cold start at temperature from -40°C to +0°C.
(4) Tantalum capacitors connected to system is suggested for bettering Ripple & Noise against operating temperature from -40°C to +0°C.
(5) 125°C OS-CON Long-life Solid capacitors are installed in secondary circuits.
Version
C
-1-
Output voltage & current rating chart
Quad Output
Typ.
(Convection-
cooled)
Typ.
(Forced-
cooled)
Max.
(Convection-
cooled)
Max.
(Forced-
cooled)
Min.
Min.
Model No.
Volt.
Volt.
Peak
(Redundant) (Single Unit)
V1
+5VDC
0.5A
0A
0A
0A
0A
0A
10A
5A
20A
20A
11A
1A
10A
10A
10A
2A
33A
33A
20A
2A
35A
35A
23A
3A
V2 +3.3VDC
V3 +12VDC
HDRC255P-110J-490(E)
0A
4A
V4
-12VDC
0A
0.5A
Notes: (1) Maximum o/p power: 90-120W for convection cooling, 150-310W for 400 or 600LFM Forced air cooling.
(2) Maximum load is the continuous operating load of each rail. But the maximum load of each rail can't be drawn from all outputs at the same time.
(3) Total combined current of V1 & V2 should be 50A.
(4) Minimum load is only required when PSUs do run in parallel.
Mechanical Dimensions (All dimensions are in mm[inch])
Derating Chart
Immunity to environmental conditions
Standard
Condition
EN5015512.2.1 &
12.2.6
EN5015512.2.4
I/P: 24-110VDC
O/P: 90-120W
(Fanless)
Pass Class TX & Column 1
Pass Class TX & Column 2
Pass Class TX & Column 3
Pass Class S2
& Class C2
I/P: 24-110VDC
O/P: 310W
Pass Class S2
Pass Class S2
Pass Class S2
V2
Pass Class TX & Column 1
I/P: 24-110VDC
O/P: 150 -310W
Pass Class TX & Column 1
Pass Class TX & Column 2
I/P: 24-110VDC
O/P: 120-310W
Pass Class TX & Column 3
Pass Class TX & Column 4
Pin assignment
Assignment
-Vin
+Vin
GND
V1
V1 S+
30
V1 Adj.
V1 C.S.
V2 S+
V2 Adj.
Pin #
47
46
45
1,2,3,4
29
35
13,14,15,16,17,18
33
32
V3
C.S.
Assignment
Pin #
V2 C.S.
V1/V2 S-
V3
V3 S+
V4
DC COM
EN#
DEG#
INH#
FAL#
5,6,7,8,9,10,11
12,19,22,24
41
34
20
36
44
21
27
38
39
42
Version
C
-2-
相关型号: