601LP4E [HITTITE]
75 dB, FAST SETTLING, LOGARITHMIC DETECTOR / CONTROLLER 10 - 4000 MHz; 75分贝,快速建立,对数检波器/控制器10 - 4000兆赫型号: | 601LP4E |
厂家: | HITTITE MICROWAVE CORPORATION |
描述: | 75 dB, FAST SETTLING, LOGARITHMIC DETECTOR / CONTROLLER 10 - 4000 MHz |
文件: | 总8页 (文件大小:331K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
HMC601LP4 / 601LP4E
v01.0509
75 dB, FAST SETTLING, LOGARITHMIC
DETECTOR / CONTROLLER 10 - 4000 MHz
Typical Applications
Features
The HMC601LP4(E) is ideal for IF and RF
applications in:
Wide Dynamic Range: up to 75 dB
Fast Pulse Response: 15/34ns (Rise/Fall Time)
Flexible Supply Voltage: +2.7V to +5.5V
Power-Down Mode
• Cellular/PCS/3G
• WiMAX, WiBro & Fixed Wireless
• Power Monitoring & Control Circuitry
• Receiver Signal Strength Indication (RSSI)
• Automatic Gain & Power Control Circuits
Excellent Stability over Temperature
Compact 4x4mm Leadless SMT Package
Functional Diagram
General Description
12
The HMC601LP4(E) Logarithmic Detector/Controller
converts RF signals at its input, to a proportional DC
voltage at its output. The HMC601LP4(E) employ
a successive compression topology which delivers
extremely high dynamic range and conversion
accuracy over a wide input frequency range. As
the input power is increased, successive amplifiers
move into saturation one by one creating an accurate
approximation of the logarithm function. The output of
a series of square law detectors is summed, converted
into voltage domain and buffered to drive the LOGOUT
output. For detection mode, the LOGOUT pin is
shorted to the VSET input, and will provide a nominal
logarithmic slope of 19mV/dB and an intercept of
-100dBm. The HMC601LP4(E) can also be used in the
controller mode where an external voltage is applied to
the VSET pin, to create an AGC or APC feedback loop.
The HMC601LP4(E) provides a 15/34ns (rise/fall time)
response time enabling RF burst detection to a pulse
rate beyond 20 MHz.
[1]
Electrical Specifications, TA = +25C, PWD = 0V, Vcc1, Vcc2 = +3.3V
Parameter
Typ.
Typ.
100
74
Typ.
500
74
Typ.
900
74
Typ.
1900
70
Typ.
2500
68
Typ.
3500
54
Typ.
4000
52
Units
MHz
dB
Input Frequency
50
3 dB Dynamic Range
3 dB Dynamic Range Center
1 dB Dynamic Range
74
-31
68
-31
68
-31
-31
-31.5
67
-31.5
65
-27
-23
dBm
dB
69
69
47
46
Output Slope
19.5
-99
-4.2
19.4
-99
-3.8
19.2
-100
-3.5
19.1
-100
-2.4
19.0
-98
19.4
-96
20.9
-85
19.6
-79
mV/dB
dBm
mdB/°C
Output Intercept
Temperature Sensitivity @ -10 dBm Input [2]
-0.8
-0.8
-4.4
-3.5
[1] Detector mode measurements; LOGOUT (Pin 17) is shorted to VSET (Pin 16).
[2] Measured from T = -40C to T = +85C
A
A
Parameter
Conditions
Min.
Typ.
10
Max.
Units
dB
RF Input (INP)
Return Loss
F = 10 - 4000 MHz, Zo = 50Ω, See plot
(Simulated)
LOGOUT Interface
Open Loop Impedance
12
kΩ
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
12 - 10
HMC601LP4 / 601LP4E
v01.0509
75 dB, FAST SETTLING, LOGARITHMIC
DETECTOR / CONTROLLER 10 - 4000 MHz
Electrical Specifications, (continued)
Parameter
Conditions
Min.
0
Typ.
0.55
4.8
Max.
Units
mA
mA
V
Current Drive (Source)
Current Drive (Sink)
For 1% change in the output voltage
Output Voltage Range
Vcc -0.13
Small Signal Response Time (10% to 90%)
Large Signal Response Time ( 0.5 dB Settling)
Output Rise Time
Pin = -60 to -57 dBm
Pin = No Signal to 0 dBm
From 0% to 90%
8
ns
50
15
<4
ns
ns
Ripple
Fin = 100 MHz
mVpp
VSET Interface
Input Impedance
30
0.6 to 1.9
75
kΩ
V
Input Voltage Range
12
Low Frequency Gain
VSET to LOGOUT
dB
kHz
Open Loop Corner Frequency
Power Down (PWD) Interface
Voltage Range for Normal Mode
Voltage Range for Shutdown Mode
Threshold Voltage
4.4
0
0.2 x Vcc
Vcc
V
V
0.8 x Vcc
Vcc/2
19.9
2.2
V
Power-up Response Time
Power-Down Response Time
Power Supply (Vcc1, Vcc2)
Operating Voltage Range
Supply Current in Normal Mode
Supply Current in Power Down Mode
50% PWD to 0.5 dB Settling of LOGOUT
50% PWD to 10% Icc
μs
μs
2.7
5.5
36
V
Vcc = +3.3V, PWD = 0V
Vcc = +3.3V, PWD = Vcc
30
1
mA
mA
Test Conditions
Parameter
Vcc1, Vcc2
Input Zo
TA
Condition
+3.3V
50Ω
+25C
Fin
900 MHz
INN Port connected to ground through a 1000pF capacitor
LOGOUT Voltage & Error
LOGOUT Voltage & Error
vs. Input Power, Fin = 10 MHz
vs. Input Power, Fin = 50 MHz
5
5
2
2
IDEAL
LOGOUT +25C
LOGOUT +85C
LOGOUT -40C
IDEAL
LOGOUT +25C
3
3
1.6
1.6
1.2
0.8
0.4
0
LOGOUT +85C
LOGOUT -40C
1
1
1.2
-1
-3
-5
-1
-3
0.8
0.4
ERR +25C
ERR +85C
ERR -40C
ERR +25C
ERR +85C
ERR -40C
-5
5
0
-75
-65
-55
-45
-35
-25
-15
-5
5
-75
-65
-55
-45
-35
-25
-15
-5
INPUT POWER (dBm)
INPUT POWER (dBm)
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, T = +25C
A
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
12 - 11
HMC601LP4 / 601LP4E
v01.0509
75 dB, FAST SETTLING, LOGARITHMIC
DETECTOR / CONTROLLER 10 - 4000 MHz
LOGOUT Voltage & Error
LOGOUT Voltage & Error
vs. Input Power, Fin = 100 MHz
vs. Input Power, Fin = 500 MHz
5
5
2
2
1.6
1.2
0.8
0.4
0
IDEAL
IDEAL
LOGOUT +25C
LOGOUT +85C
LOGOUT +25C
LOGOUT +85C
LOGOUT -40C
3
3
1.6
LOGOUT -40C
1
1
1.2
-1
-3
-5
-1
-3
-5
0.8
ERR +25C
ERR +85C
ERR -40C
ERR +25C
ERR +85C
ERR -40C
0.4
0
12
-75
-65
-55
-45
-35
-25
-15
-5
5
5
5
-75
-65
-55
-45
-35
-25
-15
-5
5
INPUT POWER (dBm)
INPUT POWER (dBm)
LOGOUT Voltage & Error
vs. Input Power, Fin = 900 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 1900 MHz
5
5
2
2
IDEAL
LOGOUT +25C
LOGOUT +85C
LOGOUT -40C
IDEAL
LOGOUT +25C
LOGOUT +85C
LOGOUT -40C
3
3
1.6
1.6
1
1
1.2
1.2
-1
-3
-5
-1
-3
-5
0.8
0.4
0.8
ERR +25C
ERR +85C
ERR -40C
0.4
ERR +25C
ERR +85C
ERR -40C
0
0
-75
-65
-55
-45
-35
-25
-15
-5
-75
-65
-55
-45
-35
-25
-15
-5
5
INPUT POWER (dBm)
INPUT POWER (dBm)
LOGOUT Voltage & Error
vs. Input Power, Fin = 2500 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 3500 MHz
5
5
2
2
IDEAL
LOGOUT +25C
LOGOUT +85C
LOGOUT -40C
LOGOUT +25C
LOGOUT +85C
LOGOUT -40C
3
3
1.6
1.6
1.2
0.8
0.4
0
1
1
1.2
-1
-3
-5
-1
-3
-5
0.8
ERR +25C
ERR +85C
ERR -40C
ERR +25C
ERR +85C
ERR -40C
0.4
IDEAL
-75 -65
0
-75
-65
-55
-45
-35
-25
-15
-5
-55
-45
-35
-25
-15
-5
5
INPUT POWER (dBm)
INPUT POWER (dBm)
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, T = +25C
A
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
12 - 12
HMC601LP4 / 601LP4E
v01.0509
75 dB, FAST SETTLING, LOGARITHMIC
DETECTOR / CONTROLLER 10 - 4000 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 4000 MHz
LOGOUT Slope vs. Frequency, Vcc = 3.3V
5
24
23
22
21
20
19
18
2
LOGOUT +25C
LOGOUT +85C
LOGOUT -40C
3
1.6
1.2
0.8
0.4
0
+25 C
+85 C
-40 C
1
-1
-3
-5
ERR +25C
ERR +85C
ERR -40C
IDEAL
12
500
1000
1500
2000
2500
3000
3500
3500
-5
4000
4000
5
-75
-65
-55
-45
-35
-25
-15
-5
5
FREQUENCY (MHz)
INPUT POWER (dBm)
LOGOUT Slope
LOGOUT Intercept
vs. Frequency, Vcc = 3.3V
vs. Supply Voltage, TA = +25C
25
-60
24
+25 C
+85 C
-40 C
500 MHz
2500 MHz
3500 MHz
4000 MHz
-70
-80
900 MHz
1900 MHz
23
22
21
20
19
18
-90
-100
-110
2.5
3
3.5
4
4.5
5
5.5
500
1000
1500
2000
2500
3000
Vcc (Volts)
FREQUENCY (MHz)
LOGOUT Intercept
LOGOUT Error vs. Input Power,
Normalized [2], Fin = 1900 MHz
vs. Supply Voltage TA = +25C
-50
2
500 MHz
2500 MHz
3500 MHz
4000 MHz
900 MHz
-60
900 MHz
1900 MHz
+85 C
-40 C
1
-70
-80
0
-90
-1
-100
-110
-2
-75
-65
-55
-45
-35
-25
-15
2.5
3
3.5
4
4.5
5
5.5
Vcc (VOLTS)
INPUT POWER (dBm)
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, T = +25C
A
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
12 - 13
HMC601LP4 / 601LP4E
v01.0509
75 dB, FAST SETTLING, LOGARITHMIC
DETECTOR / CONTROLLER 10 - 4000 MHz
LOGOUT Voltage
Input Return Loss vs. Frequency
vs. Input Power & Frequency, TA = +25C
0
2.4
-5
50 MHz
900 MHz
1.9
1.4
0.9
0.4
1900 MHz
3500 MHz
4000 MHz
-10
-15
-20
-25
-30
-35
+25 C
+85 C
-40 C
0
1
2
3
4
5
-70
-60
-50
-40
-30
-20
-10
0
10
12
FREQUENCY (GHz)
INPUT POWER (dBm)
Absolute Maximum Ratings
Vcc1, Vcc2
0V to +5.5V
ELECTROSTATIC SENSITIVE DEVICE
OBSERVE HANDLING PRECAUTIONS
PWD
0V to +5.5V
0V to +5.5V
3 mA
VSET Input Voltage
LOGOUT Output Current
RF Input Power
Junction Temperature
[1] Unless otherwise noted: Vcc1, Vcc2 = +3.3V, T = +25C
A
[2] This data is relative to the room temperature
performance of the HMC601LP4
+12 dBm
125 °C
Continuous Pdiss (T = 85°C)
(Derate 7.95 mW/°C above 85°C)
0.32 Watts
126 °C/W
Thermal Resistance (Rth)
(junction to lead)
Storage Temperature
Operating Temperature
ESD Sensitivity (HBM)
-65 to +150 °C
-40 to +85 °C
Class 1C
Outline Drawing
NOTES:
1. LEADFRAME MATERIAL: COPPER ALLOY
2. DIMENSIONS ARE IN INCHES [MILLIMETERS].
3. LEAD SPACING TOLERANCE IS NON-CUMULATIVE
4. PAD BURR LENGTH SHALL BE 0.15mm MAXIMUM.
PAD BURR HEIGHT SHALL BE 0.05mm MAXIMUM.
5. PACKAGE WARP SHALL NOT EXCEED 0.05mm.
6. ALL GROUND LEADS AND GROUND PADDLE MUST BE SOLDERED TO PCB RF GROUND.
7. REFER TO HITTITE APPLICATION NOTE FOR SUGGESTED PCB LAND PATTERN.
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
12 - 14
HMC601LP4 / 601LP4E
v01.0509
75 dB, FAST SETTLING, LOGARITHMIC
DETECTOR / CONTROLLER 10 - 4000 MHz
Package Information
Part Number
Package Body Material
Lead Finish
MSL Rating
MSL1 [1]
Package Marking [3]
H601
XXXX
HMC601LP4
Low Stress Injection Molded Plastic
Sn/Pb Solder
H601
XXXX
MSL1 [2]
HMC601LP4E
RoHS-compliant Low Stress Injection Molded Plastic
100% matte Sn
[1] Max peak reflow temperature of 235 °C
[2] Max peak reflow temperature of 260 °C
[3] 4-Digit lot number XXXX
Pin Descriptions
12
Pin Number
Function
Description
Interface Schematic
These pins are not connected internally; however,
this product is specified with these pins connected
to RF/DC ground.
1, 6, 7-13,
15, 18-24
N/C
2, 5
Vcc1, Vcc2
Bias supply. Connect supply voltage to both pins.
RF Input pins. Connect RF to INP, and AC couple
INN to ground for single-ended operation.
3, 4
INP, INN
Apply PWD >0.8xVcc to initiate a
power saving shutdown mode.
14
PWD
To ensure proper start-up apply the power-up sequence
shown in the “Power-Up Timing Diagram” attached to the
application circuit.
VSET input in controller mode. Short this
pin to LOGOUT for detector mode.
16
17
VSET
Logarithmic output that converts the input power
to a DC level in detector mode. Short this pin to
VSET for detector mode.
LOGOUT
GND
Package
Base
Exposed paddle must be connected to RF and DC ground.
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
12 - 15
HMC601LP4 / 601LP4E
v01.0509
75 dB, FAST SETTLING, LOGARITHMIC
DETECTOR / CONTROLLER 10 - 4000 MHz
Evaluation PCB
12
List of Materials for Evaluation PCB 115242 [1]
The circuit board used in the final application should
use RF circuit design techniques. Signal lines
should have 50 ohm impedance while the package
ground leads and exposed paddle should be con-
nected directly to the ground plane similar to that
shown. A sufficient number of via holes should be
used to connect the top and bottom ground planes.
The evaluation circuit board shown is available from
Hittite upon request.
Item
Description
J1 - J4
J5 - J8
C1, C2
C3, C4
R1, R2
R3-R5
PC Mount SMA Connector
DC Pin
1000 pF Capacitor, 0402 Pkg.
0.1μF Capacitor, 0402 Pkg.
5.6Ω Resistor, 0603 Pkg.
0Ω Resistor, 0603 Pkg.
HMC601LP4 / HMC601LP4E
Logarithmic Detector / Controller
U1
[2]
PCB
115244 Evaluation PCB
[1] Reference this number when ordering complete evaluation PCB
[2] Circuit Board Material: Rogers 4350
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
12 - 16
HMC601LP4 / 601LP4E
v01.0509
75 dB, FAST SETTLING, LOGARITHMIC
DETECTOR / CONTROLLER 10 - 4000 MHz
Application & Evaluation PCB Schematic
12
Notes
Note 1: The HMC601LP4 & HMC601LP4E evaluation boards are pre-assembled for single-ended input, and detector/RSSI mode.
Note 2: For single-ended input operation, use the INP port and make no connection to INN. INN is AC coupled to ground by C2
Note 3: For differential input, remove C2, and install a 1000pF capacitor in series with INN at location shown.
Note 4: For detector mode, connect high impedence volt meter to the LOGOUT port, and make no connection to VSET. LOGOUT
is shorted to VSET by R3, as required for detector mode.
Note 5: For controller mode, remove R3 and make appropriate connection to LOGOUT and VSET. In controller mode, the
LOGOUT output can be used to drive a variable gain amplifier, or a variable attenuator, either directly or through a buffer
or microcontroller. VSET should be connected to an external supply, typically between +0.6 and +1.9V.
Power-Up Timing Diagram
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
12 - 17