FCL10-302B [HOKURIKU]
Flat Type Chip Fuse;型号: | FCL10-302B |
厂家: | HOKURIKU ELECTRIC INDUSTRY CO.,LTD |
描述: | Flat Type Chip Fuse 电路保护 |
文件: | 总2页 (文件大小:181K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Flat Type Chip Fuse
Hokuriku Electric Industry Co.,Ltd
【Model Number】
FCL10-***
【Features】
■Suitable to portable electronic device for circuit protection.
■By HDK original structure, this is instant-blowing type chip fuse.
■By HDK original process, it has excellent pulse characteristic.
■Due to 1005 size, minimizing of mounting area is possible.
■No smoking, no fire occur when fused.
■Europe RoHS compliant product.
【Dimensions】
(Unit: mm)
Model No.
L
W
t
c
d
1.00±0.05
0.50±0.05
0.34±0.05
0.20±0.20
0.25±0.20
FCL10-***
①Model No.
②Rated Current
Rating(A)
③Packing Form
Model No.
FCL10
Size
1005
Marking
201
251
321
351
381
401
501
631
751
801
102
132
152
162
202
252
302
Symbol
V
Form
Paper tape
Bulk
【Designation】
0.200
0.250
0.315
0.350
0.375
0.400
0.500
0.630
0.750
0.800
1.000
1.250
1.500
1.600
2.000
2.500
3.000
FCL10
①
-
201
②
V
③
B
【Specification】
Internal
resistance
momega
1990
Operating
temperature
range
Rated current
A
Breaking
current (A)
Rated voltage
(VDC)
Model No.
Marking
Fusing performance
FCL10-201
FCL10-251
FCL10-321
FCL10-351
FCL10-381
FCL10-401
FCL10-501
FCL10-631
FCL10-751
FCL10-801
FCL10-102
FCL10-132
FCL10-152
FCL10-162
FCL10-202
FCL10-252
FCL10-302
C
D
E
F
G
H
K
L
M
N
P
R
S
U
X
Y
Z
0.200
0.250
0.315
0.350
0.375
0.400
0.500
0.630
0.750
0.800
1.000
1.250
1.500
1.600
2.000
2.500
3.000
1350
850
650
590
530
320
220
181
135
115
100
90
Rated current x200%
blow-out within 5
seconds.
- 55 ℃ ~ 125
℃
24
35
58
42
35
27
* Design・specification are subject to change without prior notice. Please check before purchase and use.
HOKURIKU
Hokuriku Electric Industry Co.,Ltd
【Structure】
Element Name
Ceramic substrate
Bottom electrode
Undercoat
No.
1
2
7
1
6
5
4
3
10
3
Fuse element Ⅰ
Fuse element Ⅱ
Protective coat
Marking
4
5
6
7
8
9
Side electrode
Ni plating
2
8
9
10
Sn plating
【Power derating curve】
■When used at ambient temperature of 70℃ or above, power rating must be derated in accordance with
the derating curve. below.
-55
0
70
125
【I2t-t characteristic】
【Fusing characteristic】
FCL10-302
FCL10-252
FCL10-202
FCL10-162
FCL10-152
FCL10-132
FCL10-102
FCL10-801
FCL10-751
FCL10-631
FCL10-501
FCL10-401
FCL10-381
FCL10-351
FCL10-321
FCL10-251
FCL10-201
Fusing time (s)
Applied Current (A)
【Caution on use】
- Please consult in advance about the use of those other than the specification written in this catalog.
- For use in the circuit which generates inrush current, please fully check durability against the inrush current.
- Please do not use this fuse for primary side.
- Please fully check characteristic against abnormality expected at normal use condition.
- We do not recommend mounting or reworking of fuse by soldering iron, since control of temperature and time is unclear.
- Please do not apply soldering iron to fuse terminal directly.
- Please do not reuse the fuse which was once mounted.
- Specification described in this catalog are subject to change without prior notice.
- When use to the apparatus that could affect human lives, such as automotive, and the apparatus that may incur serious damage
is considered, please consult in advance.
* Design・specification are subject to change without prior notice. Please check before purchase and use.
HOKURIKU
相关型号:
©2020 ICPDF网 联系我们和版权申明