1CPSA8 [HONEYWELL]
Safety Door Switch, 4PST, Momentary, 0.05A, 60VDC, Wire Terminal, Panel Mount;型号: | 1CPSA8 |
厂家: | Honeywell |
描述: | Safety Door Switch, 4PST, Momentary, 0.05A, 60VDC, Wire Terminal, Panel Mount 开关 |
文件: | 总6页 (文件大小:198K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MICRO SWITCH ™
Safety Switches
Line Guide
Full-Scale Offering. Solid, Robust Industry Knowledge. Equal
End users, OEMs, everyone faces the same challenge: ensuring
parts common sense and creativity. Each part in Honeywell Sens- equipment productivity while meeting global workplace safety
ing and Control’s (S&C) robust offering of safety switches comes
complete with amenities you’d expect from the industry leader:
superior assembly techniques for enhanced performance, ex-
tended productivity, full-line flexibility – for supreme safety.
standards. Honeywell S&C offers solutions designed to help pass
any test with the most impressive safety switch portfolio and solu-
tions – for any important, application-specific need. It’s the widest
range of sizes, sealing alternatives, enclosure materials, actua-
tor styles, and contact options available. All backed by superior
Honeywell service and global support.
• Key-operated interlock switches
• Cable-pull switches
• Hinge-mount switches
• Trapped key and solenoid key switches
• Positive-opening contacts
• Non-contact products for door detection
• Miniature switches for smaller openings
• Reduced installation time and cost
• Tamper resistant
FEATURES
plications • Positive opening operation of
normally closed contacts (conforming to
IEC/EN60947-5-1-3) • Rugged housing
(zinc die-cast) • Full range of actuator
heads and levers • Sealing up to IP67;
NEMA 1, 4, 12, and 13 • Snap-action and
slow-action basic switches • International
conduit sizes • Galvanically isolated con-
tacts • UL listed, CSA and CE certified,
SIL 3 capable
wiring small switch enclosures).Durable,
tough design. Global acceptance.
GKM Series Global Miniature.
Features: Red body color • Integrated
cable or connector(s) • Bottom or side-
entry • Bottom, side-entry, or dual connec-
tor versions (for daisy chaining a number
of switches together) • 90° or straight key
• Extremely compact enclosure • Positive
opening operation of normally closed con-
tacts (conforming to IEC/EN 60947-5-1-3)
• IP67 rating • Stackable design allows
side-by-side mounting • Robust keys • UL
listed, CSA certified, CE compliant, SIL 3
capable • High current switching capabili-
ties • Small door swing radius down to 160
mm [6.3 in]
FF and FFS Series Non-contact.
Features: Red body color (except FFS
and stainless steel offerings) • Tamper-
proof electronic switching • 7 mm to 10
mm [0.28 in to 0.4 in] operating distance
• Guard status indication • CE, UL approv-
als • Options of one or two safety contacts
• Tested to over 1,000,000 operations
• Simple mounting (M18/30 thread mount-
ing or frame-mountable versions • Guard
status indication available • ac and dc
versions
Benefits: Standard mounting and char-
acteristics are globally available and ac-
cepted. Welded NC contacts will separate
(vital security in safety applications).
Range of actuation methods for detecting
conditions in guarding and machine status
applications. Wiring and body flexibility.
Often suitable for inductive switching and
safety relay interfaces.
Benefits: Tolerates misalignment over
lifetime of machine. Gap between sensor
and actuator large, enabling non-contact
switching. FFS offers superior tamper
resistance. Integrates easily with control
modules. Easy daisy chain configurations.
Benefits: Reduced installation time and
costs. Flexibility of mounting and ac-
tuation options. Ability to function as a
final switching device for small, low-risk
equipment. Operates with safety control
modules for more complex applications.
Fits extremely compact spaces, and is
often suitable for wet applications. Simple
mechanical and electrical redundancy for
some options. Easy application in multiple
door modular machinery (no difficulty in
GSX Series.
Features: Snap action contacts with
positive break in an explosion-proof
housing • Positive action push plunger
breaks current upon opening of door
or aperature • Explosion-proof housing
GSS Series Safety Limits.
Features: Red body color • EN50041 and
EN50047 mounting and characteristics
• IEC electrical standard for global ap-
continued on page 4
MICRO SWITCH™ Safety Switches Line Guide
The most powerful part:
Possibilities.
Honeywell S&C offers one-stop
convenience for engineering
Safety Switches
GKM Series Global Miniature
FF and FFS Series
Non-contact
excellence – meaning top-
notch products or completely
customized creations, as well
as all the possibilities that
lie between. You may have
‘impossible’ needs and dead-
lines. But the experts at Hon-
eywell are ready with powerful
safety solutions.
key switch – very small, cable/connector contactless door detection; very small,
fitted
Attributes
cable/connector fitted
small doors and apertures
ABS resin-filled, stainless steel
UL, CE
Potential applications
Housing
small doors and apertures
glass-filled polyester
UL, CE, SIL 3 capable
IP66/67; NEMA 1, 12, 13; EN60529
Approvals
IEC/NEMA rating
IP67; NEMA 4
small footprint; connectorized; side-exit
cable connector
large actuation window to reduce mis-
alignment issues
Differentiator
From the factory floor to the
assembly line, from packag-
ing machinery to robot cells
– from the smallest spaces
to any worldwide application
or mount, Honeywell delivers
ultimate reliability and safety in
compact, cost-effective pack-
ages.
Body dimensions (less levers)
H x W x D mm[in]
69,4 mm x 34,0 mm x 16,0 mm
[2.73 in x 1.34 in x 0.63 in]
82,5 mm x 19 mm x 17 mm
[3.25 in x 0.75 in x 0.67 in]
Temperature
-25 °C to 85 °C [-13 °F to 185 °F]
-10 °C to 55 °C [14 °F to 131 °F]
Safety Switches
GSS Hinge Mount
Safety Limits
GSS Series Safety
Limits
GSX Series Explosion-
Proof Safety Switch
GK Series Key-Operated
Safety Interlock
mounted to the door hinge –
detects door angle
Attributes
global safety switch
explosion-proof, safety switch
heavy-duty key switch
medium/large doors and
apertures
Potential applications
medium/large doors
gates, doors, access panels, cages large, heavy door applications
Housing
glass-filled polyester; die-cast
UL, CE, SIL 3 capable
die-cast
die-cast
die-cast
Approvals
UL, CE, SIL 3 capable
IP67; NEMA 1, 4, 12, 13
UL, ATEX, IECEx
IP67; NEMA 1, 3, 4, 12, 13
UL, CE, SIL 3 capable
IP67; NEMA 1, 4, 12, 13
IEC/NEMA rating
IP67; NEMA 1, 4, 12, 13
IECEx approvals. More than 10000
actuator/switching combos
Differentiator
highly visible
highly visible
extremely heavy-duty, rugged
Body dimensions (less 83,0 mm x 30,5 mm x 30,0 mm
83,0 mm x 30,5 mm x 30,0 mm 154,2 mm x 44,5 mm x 72 mm
121,6 mm x 42 mm x 42,6 mm
[1.79 in x 1.652 in x 1.68 in]
levers) H x W x D
[3.27 in x 1.2 in x 1.18 in]
[3.27 in x 1.2 in x 1.18 in]
[6.07 in x 1.75 in x 2.84 in]
-25 °C to 85 °C
[-13 °F to 185 °F]
-25 °C to 85 °C
[-13 °F to 185 °F]
-40 °C to 70 °C
[-40 °F to 158 °F]
-25 °C to 85 °C
[-13 °F to 185 °F]
Temperature
2
www.honeywell.com/sensing
Safety Switches
24CE and 924CE Series
GKE Series Dual Entry Safety GKN Series Safety Interlock
standard offering, three conduit, minimal
Attributes
very small, cable/connector fitted
key switch – small, standardized housing
variances
Potential applications
Housing
small doors and apertures
Die-cast
small doors and apertures
glass-filled polyester
small/medium doors and apertures
glass-filled polyester
Approvals
UL, CE, SIL 3 capable
UL, CE, CCC, SIL 3 capable
UL, CE, CCC, SIL 3 capable
IP67;
IEC/NEMA rating
Differentiator
IP67
IP66; NEMA 1, 12, 13
NEMA 1, 4X (indoor use only), 12, 13
toughest safety switch available
small footprint key switch
molded 0.5 in NPT conduit
Body dimensions (less levers)
H x W x D mm[in]
49,0 mm x 40,0 mm x 16,0 mm
[1.93 in x 1.57 in x 0.63 in]
92,2 mm x 24,2 mm x 29,4 mm
[3.63 in x 0.95 in x 1.16 in]
90,0 mm x 40,0 mm x 33,0 mm
[3.55 in x 1.57 in x 1.30 in]
Temperature
0 °C to 70 °C [32 °F to 160 °F]
-25 °C to 85 °C [-13 °F to 185 °F]
-25 °C to 70 °C [-13 °F to 158 °F]
Safety Switches
GKS Series Multi-Entry
Trapped Safety Interlock
GKR/L Dual-Entry Solenoid
Safety Interlock
CPS Series Cable Pull Safety
Switch
trap and hold the key until hazard has
been removed
Attributes
heavy-duty key switch/solenoid lock
single/dual head rope pull
Potential applications
Housing
large, heavy door applications
glass-filled polyester
large, heavy door and machine apps
die-cast
conveyor applications
die-cast
Approvals
UL, CE, CCC, SIL 3 capable
UL, CE, SIL 3 capable
UL, CE, SIL 3 capable
IP67;
IEC/NEMA rating
Differentiator
IP68; NEMA 1, 4, 6P, 12, 13
IP67; NEMA 1, 4, 12, 13
NEMA 1, 4X (indoor use only), 12, 13
compact, trapped key design
extremely rugged trapped key switch
rugged housing, ease of installation
Body dimensions (less levers)
H x W x D mm[in]
196,8 mm x 40 mm x 41 mm
[7.75 in x 1.57 in x 1.61 in]
149,0 mm x 110,0 mm x 48,8 mm
[5.85 in x 4.33 in x 1.92 in]
165,1 mm x 79,8 mm x 325,9 mm
[6.5 in x 3.14 in x 12.75 in]
Temperature
-25 °C to 50 °C [-13 °F to 122 °F]
-25 °C to 85 °C [-13 °F to 185 °F]
-40 °C to 85 °C [-40 °F to 185 °F]
www.honeywell.com/sensing
3
for hazardous locations • Sealed for
protection against corrosion, water, dust,
and oil as defined in NEMA 1, 3, 4, 12,
and 13 and IP67 • Complies with ATEX,
IECEx, and UL/CSA regulations • Simple
installation • Extensive switch options and
actuator styles
Benefits: Designed for use on machinery
where key removal brings the machine to
an immediate safe condition. Potential ap-
plications include Hinged or sliding guard
doors, screens, protective covers and
enclosures on: machine tools machinery,
metalworking machines, special purpose
machinery, robotics assembly cells, and
plastic molding machines.
ings (knock-out style) • Switch position
provides status
Benefits: Ease of safety module integra-
tion. Tough, cost-effective, double-insu-
lated enclosure. Choice of key trapping
methodology. Four contacts can be
arranged in any configuration and multiple
voltages for every geography. Ability to
open door (in case of power loss, etc.).
Flexible wiring options. Can diagnose sta-
tus of gate/door open, closed, locked.
Benefits: To comply with explosion-proof
requirements, the GSX has flame paths
within the housing, which cool exploding
gases below the ignition temperature
before they reach explosive gases
surrounding the housing. Flame paths
are (1) an extended plunger between
the switch cavity and head and (2) the
cover-housing threads on the front of the
switch. Potential applications include
gates, doors, access panels, and/or
cages on machinery in hydrocarbon
refining, chemical processing, agricultural
equipment, food processing, and grain
elevators.
GKE Series Dual Entry Safety Inter-
lock.
Features: Red body color • Positive
opening safety contacts • Head orienta-
tion configured to order • Rotating head
• Head may be ordered in four possible
orientations • Double insulation per IEC
60947-5-1 • Choice of two standard actua-
tors • Small size •cULus, CE, CCC, SIL 3
capable
GKR/GKL Dual-Entry Solenoid
Trapped Key Safety Interlock.
Features: Metal housing • Red body
color • Solenoid power to lock or power to
unlock • Side or top key entry • Separate
switch detection for key position and sole-
noid status • Available with several switch
configurations • 100 mm [3.94 in] x 100
mm [3.94 in] mounting • Choice of four
heavy-duty keys • Key retain force 1000
N max. • IP68 (NEMA 6P) • Two solenoid
voltages available • Dual LEDs • UL listed/
CSA certified/CE compliant, SIL 3 capable
• Fluorocarbon-sealed enclosure available
Benefits: Small footprint. Applicable to
various safety schemes, including low
and high voltage/energy. May be used as
final switching device for small, low-risk
applications. Environmentally sealed for
challenging applications.
GKN Series Safety Interlock.
Features: Red body color • Positive open-
ing operation of normally closed contacts
(conforming to IEC/EN 60947-5-1-3)
• Choice of actuators • Double insulated
per IEC 60947-5-1 • Global approvals
(cULus, CE, CCC, SIL 3 capable) • Three
cable entries • Large wiring cavity • Large
M20 cable entry • Oblique native 0.5 in
NPT conduit • Common footprint • Four-
entry head
Benefits: Robust body design for harsh
environments. High force resistance.
Flurocarbon version often suitable for met-
alworking fluid-splash environment. Allows
up to eight key entry positions. Standard
mounting, key mounting flexibility and
security. Often suitable for harsh-duty en-
vironments. Operates at standard control
voltage. Global acceptance.
GKN Series Safety Interlock.
Features: Red body color • Positive open-
ing operation of normally closed contacts
(conforming to IEC/EN 60947-5-1-3)
• Choice of actuators • Double insulated
per IEC 60947-5-1 • cULus, CE, CCC,
SIL 3 capable • Three cable entries
• Large wiring cavity • Large M20 cable
entry • Oblique native 0.5 in NPT conduit
• Common footprint • Four-entry head
Benefits: Flexibility in positioning on door/
machine. Ease of wiring/installation. No
conduit or cable adapters. Meets global
safety standards. Drop-in compatibility
with most brands. No need to reconfigure
head orientation.
CPS Series Cable Pull Safety.
Benefits: Flexibility in positioning on door/
machine. Ease of wiring/installation. No
conduit or cable adapters. Meets global
safety standards. Drop-in compatibility
with most brands. No need to reconfigure
head orientation.
Features: 2CPS dual head for dual span
• 1CPS single head for single span •
Red body color • Direct opening action
of normally closed contacts if emergency
occurs • Typical cable span of 76 m [250
ft], longer spans available • UL listed, CE
compliant, SIL 3 capable • Highly visible
GK Series Key-Operated Safety
Interlock.
Features: Red body color •Positive open-
ing operation of normally closed con-
tacts • Standard mounting per EN50041
•Available with 2NC/2NO, 3NC/1NO or
4NC positive opening contacts • Side or
top key entry • Unique friction feature for
key retention • Choice of four heavy duty
keys (Key sold separately) • Die-cast zinc
housing • Lockout device available • UL,
CSA, CE, SIL 3 capable
GKS Series Multi-Entry Trapped Key status indicator • Gold-plated contacts
Safety Interlock.
available • Rugged, die-cast zinc housing
• Optional hardware packs
Features: Red body color • Global ap-
provals (CE, cULus, CCC, SIL 3 capable)
• Glass-filled polyester body • Power-to-
lock and power-to-unlock schemes for key
trap • Flexible switching arrangement • 24
Vdc, 110 Vac, and 230 Vac coil voltages •
Override mechanism in cover • Four head
positions available • Three conduit open-
Benefits: Easy to identify tripped switch in
emergency. Extremely rugged design for
harsh environments or applications. Mini-
mizes false triggers in varying temperature
environments (i.e., semi-enclosed convey-
or spaces). Easy wiring and installation.
Simple set-up.
Warranty. Honeywell warrants goods of
its manufacture as being free of defective
materials and faulty workmanship.
While we provide application assistance
personally, through our literature and
the Honeywell web site, it is up to the
customer to determine the suitability of the
product in the application.
WARNING
RISK TO LIFE OR PROPERTY
•Never use this product for an
application involving serious risk to
life or property without ensuring that
the system as a whole has been
designed to address the risks, and
that this product is properly rated
and installed for the intended use
within the overall system.
Honeywell’s standard product warranty
applies unless agreed to otherwise by
Honeywell in writing; please refer to your
order acknowledgement or consult your
local sales office for specific warranty
details. If warranted goods are returned to
Honeywell during the period of coverage,
Honeywell will repair or replace, at its
option, without charge those items it finds
defective. The foregoing is buyer’s sole
remedy and is in lieu of all warranties,
expressed or implied, including those
of merchantability and fitness for a
particular purpose. In no event shall
Honeywell be liable for consequential,
special, or indirect damages.
Specifications may change without notice.
The information we supply is believed to
be accurate and reliable as of this printing.
However, we assume no responsibility for
its use.
Failure to comply with these
instructions could result in death or
serious injury.
For more information about Sensing and
Control products, visit www.honeywell.
com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
MISUSE OF DOCUMENTATION
•The information presented in this
catalogue is for reference only. DO
NOT USE this document as product
installation information.
•Complete installation, operation and
maintenance information is provided
in the instructions supplied with each
product.
Failure to comply with these
instructions could result in death or
serious injury.
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
004757-6-EN IL50 GLO
July 2011
Copyright © 2011 Honeywell International Inc. All rights reserved.
www.honeywell.com
Notes
相关型号:
1CPSA8A
Snap Acting/Limit Switch, 4PST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSA8B
Snap Acting/Limit Switch, 4PST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSB1B
Snap Acting/Limit Switch, SPST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSB2A
Snap Acting/Limit Switch, DPST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSB2B
Snap Acting/Limit Switch, DPST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSB3A
Snap Acting/Limit Switch, 4PST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSB3B
Snap Acting/Limit Switch, 4PST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSB4A
Snap Acting/Limit Switch, 4PST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSB4B
Snap Acting/Limit Switch, 4PST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSB5A
Snap Acting/Limit Switch, SPST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSB5B
Snap Acting/Limit Switch, SPST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
1CPSB6A
Snap Acting/Limit Switch, DPST, Momentary, 6A, 120VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
HONEYWELL
©2020 ICPDF网 联系我们和版权申明