20183 [HONEYWELL]
Other AC and DC Meters Available; 其他交直流两用仪表可用型号: | 20183 |
厂家: | Honeywell |
描述: | Other AC and DC Meters Available |
文件: | 总6页 (文件大小:347K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
If you have not found what you are looking for or you
have further questions, please feel free to call us at
217-753-7797 or fax us at 217-753-7789. It will help
us process your request more efficiently and effectively
if you can provide as much detailed information about
your requirements/ application as possible.
Sensing and Control
Th a n k s fo r co n sid e rin g Ho b b s m e te rs fro m
Ho n e y w e ll!
MANUFACTURING
Honeywell Hobbs’ commitment to the customer in
past years and present is what has helped us develop
our world-class manufacturing systems. Some of the
methods by which we continuously improve our
products and processes are as follows:
Six Sigma methodology is a strategy used to accelerate
•
improvements in our processes, products and services, and
to reduce manufacturing costs and improve quality. It
achieves this by relentlessly focusing on eliminating waste
and reducing defects and variations.
Continous Flow Process utilizing “Rabbit Chase” concepts
are used in the focused factories in order to achieve the
lowest total cost, defect-free product.
•
Single Minute Exchange of Dies (SMED method) provides
reduced time in molding cell.
•
Statistical Process Control is used for measuring critical
dimensions and controlling manufacturing processes.
•
Poka-Yoke method and computerized test equipment are
utilized to eliminate scrap and rework.
•
Kanban cards are used to pull raw material and piece parts
through the factory.
•
Bar coding and electronic data interchange (EDI)
are available.
•
QUALITY SYSTEMS
It is the goal of Honeywell Hobbs to meet customer value-needs through continuously improved products and processes. That is the
basis by which we work to create a partnership with our customers. Evidence of our commitment is proven by a goal of a Shipped
Product Quality Level (SPQL) of 100 ppm. We utilize Advanced Quality Planning and QS9000 based quality systems.
© 2003 Honeywell International Inc. All Rights Reserved.
Sensing and Control
www.honeywell.com/hobbs
email: www.honeywellhobbs.marketing@honeywell.com
Honeywell
P.O. Box 19424
Springfield, IL 62794-9424
USA
Catalog 20-1103, GLO Printed in the USA
Custom Instrument
Panel Clusters
Other AC and DC Meters Available
Let Hobbs custom design your display panel
saving you time and money. We can
assemble a panel to your specifications that
frees up your engineering resources,
reduces parts counts and reduces your
vendor base.
Round Flush with Retainer Mount
The Hobbs brand is well known
worldwide for the development of
quality electro-mechanical products.
The invention of the first electrically
wound automobile clock in 1938
created what is now known as
Honeywell Hobbs. John Weston
Hobbs was the inventor that cultivated
this electrically-wound vehicle clock
into a company that has over the
years expanded to include hour
meters, pressure and vacuum
switches, halogen lamps, transmission
shifters, and other custom
electro-mechanical products.
Honeywells’ broad customer and
market base includes industries such
as automotive, agricultural, material
handling, construction, marine,
medical, heavy truck, lawn and
garden, recreational, generators,
compressors and aviation.
Round Slotted 3 screw
Warranty and remedy
Contact Hobbs for more
information and specifications
on above meters.
Honeywell warrants goods of its
manufacture as being free of defective
materials and faulty workmanship. Contact
your local sales office for warranty
Hour Meter Accessories
information. If warranted goods are
returned to Honeywell during the period of
coverage, Honeywell will repair or replace
without charge those items it finds defective.
The foregoing is Buyer’s sole remedy and is
in lie u o f a ll o th e r w a rra n tie s,
e x p re sse d o r im p lie d , in clu d in g
th o se o f m e rch a n ta b ility a n d fitn e ss
fo r a p a rticu la r p u rp o se .
Mo u n tin g b ra ck e ts. For mounting hour
meters in any location when panel installation is
not practical. Multiple holes allow positioning
for easy reading. Foot of bracket can be bent
when necessary. Part Number M-329
(2 13/ 16” x 4”) for meter only. Part Number
M-558 (4” x 5 1/ 8”) when meter and damper
are used together.
While we provide application assistance,
personally, through our literature and the
Honeywell web site, it is up to the customer
to determine the suitability of the product in
the application.
Da m p e r. Protects meter from severe
vibration. Use on panel or with Part Number
M-558 bracket. Part Number M-3888
(3 7/ 8” dia.) for three-screw type DC meters.
Specifications may change at any time
without notice. The information we supply
is believed to be accurate and reliable as
of this printing. However, we assume no
responsibility for its use.
Honeywells’ commitment to
continuous improvement and total
quality management will allow for
further expansion of its product lines
and customer base while maintaining
the highest standards of excellence.
Sales and Service
Honeywell serves its customers through a
worldwide network of sales offices and
distributors. For application assistance,
current specifications, pricing or name of
the nearest Authorized Distributor, contact a
nearby sales office or
Pa n e l m o u n tin g b ra ck e t. Designed to bolt to
a flat surface area 2 13/ 16” x 5 1/ 4”. Provides
easy-to-read meter position. Part Number M-486
for three-screw type DC meter only.
INTERNET: www.honeywell.com/ hobbs
E-mail:
honeywellhobbs.marketing@honeywell.com
Contents:
Wa rra n ty Pe rio d s:
The products listed are warranted
for the periods shown:
An g le b ra ck e t. For two-screw flange
AC and DC rectangular meters only,
when panel mounting is not practical.
Part Number 23944.
• LCD
• D.C.
• A.C.
P. 3-5
P. 6-7
P. 8-11
P. 11
9 8 0 0 0 Se rie s..................2 y e a rs
8 5 0 0 0 Se rie s..................2 y e a rs
2 0 0 0 0 Se rie s..................2 y e a rs
• Accessories
• Warranty
w w w .h o n e y w e ll.co m / h o b b s
P. 11
11
2
28100 Series
AC Multi-Range Meters
LCD Hour Meters
98000 Series
Unlike conventional AC hour meters that are
limited to one primary voltage andfrequency, the
Hobbs Multi-Range Quartz hour meter will
operate over a full range of voltages and
frequencies. The meters will work accurately
over a voltage range of 90 VAC to 264 VAC
and at frequencies of either 50 Hz or 60 Hz.
This unique feature means that one hour meter
will work for virtually any application anywhere
in the world!
The Hobbs 98000 Series LCD hour
meters provide a large easy-to-read
display in a conventional size
package. The hour meters are
available in a variety of mounting
styles and voltage ranges that will fit
virtually any application.
Re ta in e r Mo u n t
Operating
Voltage
Part #
Sp e cifica tio n s
Sp e cifica tio n s:
• Operating Voltage: 90 to 264 VAC
• Frequencies: 50 to 60 Hz
• Temperature Range: -40˚F to +185˚F
• Run Accuracy ±200ppm; ±0.02%
• Start Time: maximum 1second
• 6 Digit Display
• Digit Height: 6mm
• Power draw: .8 mA at 12 VDC
(Power Terminal)
• Termination: 1/ 4” blade
3/ 16” blade optional
• Temperature Range:
Operating: -40˚C to +85˚C
• Vibration: 20 g’s per SAE J1378
• Shock: 55 g’s per SAE J1378
• Operating ranges:
4.5 to 16 VDC (optional)
9 to 64 VDC
90-264 VAC
28100
Retainer Mount:
Panel cutout 1.45 x .95
rectangular opening.
2 Scre w Sta n d a rd Be ze l
Two .150 holes spaced 1.750*
Fe a tu re s
2 Screw Standard:
Panel cutout 1.45 x .95
rectangular opening
Two .150 holes
spaced 1.750*
Operating
Voltage
• Records time 0 to 99,999.9 hours
• Accuracy ±0.02%
• UL Recognized
• CSA (UL)
• CE Mark
Terminals
Part #
9 to 64 VDC
2 terminal
98310
3 terminal
9 to 64 VDC
9 to 64 VDC
with enable
98320
98300
2 Scre w
Sta n d a rd Be ze l
• Totally sealed from dirt and moisture
• Termination
4 terminal
resettable
- 1/ 4” spade
Operating
Part #
Be n e fits
Voltage
• Reduced parts count
• Reduced inventories
• Fewer purchase orders
• Eliminate production line errors
• Reduce service parts
2 Screw Standard:
Panel cutout 1.45 x .95
rectangular opening.
90 to 264 VAC
28101
>64 VDC Contact Factory
• Display:
0 to 99,999.9 Hours
0 to 999,999 Counter
• Transient Voltage Protection
Load Dump
Two .150 holes spaced 1.750*
O p tio n s
• Wire leads
• Custom lens
Inductive
• Terminals (up, down, straight)
E M I
Reverse Polarity
WARN IN G!
Applied voltage not to exceed 264 Vac RMS. This meter
was not intended to be used in applications where
excessive transient voltages are present. It is the
responsibility of the customer to determine the suitability
of this device for use in their system.
2 Scre w De lu x e Be ze l
Operating
Voltage
Part #
2 Scre w De lu x e Be ze l
Fe a tu re s
• Totally sealed from moisture
and dirt
• Direct replacement for
current hour meter
2 Screw Deluxe:
90 - 264 VAC
28103
Operating
Voltage
Panel cutout 1.45 x .95
rectangular opening
Two .150 holes
2 Screw Deluxe:
Panel cutout 1.45 x .95
rectangular opening.
* Panel cutout dimensions are ± .010 tolerance
All dimensions shown in inches and (metric)
Terminals
Part #
9 to 64 VDC
spaced 1.750*
2 terminal
98313
Two .150 holes spaced 1.750*
• No battery backup needed
• Fits in existing panel openings
• Custom bezels and
dial artwork available
• Snap-in retainer mount
combines easy installation with
rugged design
3 terminal
9 to 64 VDC
9 to 64 VDC
with enable
98323
98303
4 terminal
resettable
• Compact Depth
• Rugged Design
• Pulse Counter Option
• Reset Option
• Run Indicator
Ro u n d Bla ck Be ze l
3 Scre w
Operating
Operating
Part #
Part #
Voltage
Voltage
90 - 264 VAC
28104
90 - 264 VAC
28105
* Panel cutout dimensions are ± .010 tolerance
All dimensions shown in inches and (metric)
Flush Mount (Retainer) 2.24”:
Panel cutout 2.00
diameter opening*
3 Screw Mount:
Panel cutout 2.00 diameter opening
Three .125 holes equally
10
3
spaced on 2.42 bolt circle diameter*
20000 Series Deluxe AC Hour Meters
LCD Hour Meters
98000 Series
2 0 0 0 0 Se rie s W irin g Dia g ra m s
120VAC Meter Applications
Sing le p ha se , 2 w ire ,
N
1 2 0 V syste m : Connect
power wire to one terminal
HM
Re ta in e r Mo u n t
and neutral wire to opposite
terminal.
Operating
LCD Me te r
Sing le p ha se , 3 w ire ,
Voltage
Terminals
APPLICATIO N S
Part #
Re cta n g u la r Re ta in e r Mo u n t
Operating
N
N
1 2 0 / 2 4 0 V syste m : Connect
any one power wire to one
terminal and the neutral wire to
the opposite terminal.
9 to 64 VDC
2 terminal
98311
• Garden Tractors
• Generators
• Utility Vehicles
• Construction Equipment
• Material Handling Equipment
• Recreational Vehicles
• Medical
• Electronic Panels
• Rental Equipment
• Boom Lifts
Voltage
Hertz Termination
Part #
HM
3 terminal
with enable
9 to 64 VDC
9 to 64 VDC
108-132 VAC
108-132 VAC
108-132 VAC
108-132 VAC
216-264 VAC
216-264 VAC
216-264 VAC
50
50
60
60
50
50
60
Screw*
Blade**
Screw*
Blade**
Screw*
Blade**
Screw*
20174
20183
20116
20182
20171
20170
20177
98321
98301
Thre e p ha se , 4 w ire w ye ,
1 2 0 / 2 0 8 V syste m : Connect
any one power wire to one
terminal and the neutral wire
to the opposite terminal.
4 terminal
resettable
Retainer Mount:
Panel cutout 1.45 x .95
rectangular opening*
HM
Rectangular Retainer:
Panel cutout 1.45 x .95
rectangular opening*
Thre e p ha se , 4 w ire d e lta
w ith a hig h le g ,
1 2 0 / 2 4 0 V syste m : Connect
any one of the two available
120V power wires to one
terminal of the meter and the
neutral wire to the opposite
teminal. Do not connect the high
leg (208V) to the meter.
N
• Pressure Washers
• Sweepers
• Test Equipment
HM
Ro u n d Ch ro m e Be ze l
240VAC Meter Applications
Operating
Voltage
Sing le Pha se , 2 w ire ,
N
Terminals
Part #
* Panel cutout dimensions are ± .010 tolerance
All dimensions shown in inches and (metric)
2 4 0 V syste m : Connect
power wire to one terminal
and neutral wire to opposite
terminal.
HM
9 to 64 VDC
2 terminal
98314
3 terminal
with enable
9 to 64 VDC
9 to 64 VDC
98324
98304
Sing le p ha se , 3 w ire ,
1 2 0 / 2 4 0 V syste m : Connect
meter across two high sides of
the line. Do not connect the
neutral wire to the meter.
4 terminal
resettable
Flush Mount (Retainer) 2.27”:
Panel cutout 2.00
diameter opening*
N
Sq u a re Re ta in e r Mo u n t
Operating
HM
HM
Voltage
Hertz Termination
Part #
108-132 VAC
108-132 VAC
216-264 VAC
216-264 VAC
50
60
50
60
20176
20115
20173
20179
Screw*
Screw*
Screw*
Screw*
Thre e p ha se , 3 w ire d e lta ,
2 4 0 V syste m : Connect meter
across any two power lines.
Square Retainer: Panel
cutout 1.45 x .95
rectangular opening*
Thre e p ha se , 4 w ire d e lta
w ith a hig h le g ,
* UL Listed, CSA Certified and CE Mark
** UL Recognized, CSA Certified and CE Mark
1 2 0 / 2 4 0 V syste m :
Connect any one power wire to
one terminal of the meter.
Connect one of the remaining
two power lines to the opposite
terminal. Do not connect the
neutral wire to the meter.
N
Ro u n d Bla ck Be ze l
HM
Operating
Voltage
Terminals
Part #
* Panel cutout dimensions are ± .010 tolerance
All dimensions shown in inches and (metric)
9 to 64 VDC
2 terminal
98312
3 terminal
CAUTION: Always make sure power is removed from equipment before working on
electrical circuits! Only qualified personnel should make electrical connections.
Damage to equipment and/ or serious bodily injury can result from improperly made
electrical connections, or a failure to adhere to normal electrical safety guidelines.
9 to 64 VDC
9 to 64 VDC
with enable
98322
98302
Flush Mount (Retainer) 2.27”:
Panel cutout 2.00
diameter opening*
4 terminal
resettable
9
4
Deluxe AC Hour Meters
LCD Hour Meter Module
20000 Series
When there’s a need to keep track of run
time, quality-minded companies choose
Hobbs! Whether it’s for testing purposes,
leasing applications, maintenance reasons,
and/ or warranty programs, you want an
accurate and reliable hour meter. The
Hob b s 2 0 0 0 0 Se rie s hour meter delivers!
The Hobbs LCD hour meter module is a
custom engineered elapsed time meter
designed to be mounted directly to your
printed circuit board (PCB). It can be used
in a variety of AC or DC applications that
require an hour meter, counter or odometer
for preventive maintenance, warranty
verification, renting and leasing.
Re cta n g u la r 2 Scre w
Operating
To ensure our high standards of quality, all
parts are in-process inspected. Every meter
must pass 100% function and timing
accuracy tests before shipping. These
“Deluxe” AC meters are also totally sealed
and
benefit from an uncommon design which
integrates the motor and frame into one
substructure.
Voltage
Hertz
Termination
Part #
20028
20034
20001
20035
20029
20036
20007
20037
50
50
60
60
50
50
60
60
Sp e cifica tio n s
• 6 digit/ 6mm display
• ±0.02% Accuracy
108 to 132 VAC
108 to 132 VAC
108 to 132 VAC
108 to 132 VAC
216 to 264 VAC
216 to 264 VAC
216 to 264 VAC
216 to 264 VAC
Screw *
7” Leads **
Screw *
7” Leads **
Screw *
7” Leads **
Screw *
7” Leads **
• Vibration tested per MIL-M-3971D at
10 g’s and SAE J1378 at 20 g’s
• Shock tested per MIL-M-3971D at 75 g’s
and SAE J1378 at 55 g’s
• Operating temp. range -40˚C to +85˚C
• Operating voltage range 9 to 64 VDC
(optional 4.5 to 16 VDC)
• Transient Voltage Protected
Over Voltage
Two-Screw Mount: Panel cut out
1.45 x .95 rectangular
opening. Two .150 holes
spaced 1.750.*
Sp e cifica tio n s
• Records up to 99,999 hours
Automatic recycle to zero
• 24,120 and 240 VAC models available
(Range ±10%)
Load Dump
D.C. Ve rsio n
• 50 and 60 Hertz versions
• 3.0 watts power rating
• Operating temperature: -65°F to +154°F
(-54°C to +68°C)
• Accuracy: ±.02%.
• Weight: 3 oz
Inductive
EMI
Reverse Polarity
Operating
Voltage
9 to 64 VDC
Termination
Part #
• Power Consumption
.8 ma max at 12V (power terminal)
• Start time: maximum 1 second
4 pin
98706
with enable & reset
4 pin
4.5 to 16 VDC
98707
• Screw termination or 7” lead wires
• Lens material:
3-screw mount: Glass
LCD Mo d u le
APPLICATIO N S
All Ho b b s m o d u le s h a ve cru cia l
co m p o n e n ts e x p o se d . Th e m o d u le
m u st b e su fficie n tly p ro te cte d if
u se d in a n e n viro n m e n t o th e r th a n
sp e cifie d . Co n su lt Ho b b s
m a rk e tin g d e p a rtm e n t w h e n
su ita b ility o f a p p lica tio n is
q u e stio n e d .
All others: Polycarbonate
• Case material: Polycarbonate
• Number size: 0.12” (3mm)
• UL Listed (File # E47098): Screw terminals
• UL Recognized: Wire lead versions
• CSA Certified (File # LR42455)
• Conforms to MIL-M-3971 *
• CE Mark
Co u n te r Ve rsio n
• Medical
Ro u n d 3 Scre w
• Vending Machines
• Floor Cleaning Equip.
• Electronic Panels
• Instrument Panels
• Recreational
Operating
Operating
Voltage
Voltage
9 to 64 VDC
with reset
Termination
Part #
Hertz
Termination
Part #
108 to 132 VAC
108 to 132 VAC
108 to 132 VAC
108 to 132 VAC
216 to 264 VAC
216 to 264 VAC
216 to 264 VAC
216 to 264 VAC
4 terminal
50
50
60
60
50
50
60
60
98704
Screw *
7” Leads **
Screw *
7” Leads **
Screw *
7” Leads **
Screw *
7” Leads **
20016
20042
20017
20043
20018
20044
20019
20045
9 to 64 VDC
without reset
• Office Equipment
3 terminal
98705
Three-Screw Mount: Panel cut out
2.00 diameter opening. Three
.125 holes equaly spaced on
2.42 bolt circle diameter.*
Fe a tu re s
• Large easy-to-read numbers
• Silent operation
O p tio n s
Fe a tu re s
• Polycarbonate, shock resistant, tamper
proof case
• Totally sealed *
• Single phase, synchronous, permanently
lubricated motor
• Custom logo dials, 1/ 4” blade terminals,
special wire lengths.
4.5 to 16 VDC
• Low power demand
* Panel cutout dimensions are ± .010 tolerance
All dimensions shown in inches and (metric)
• Resettable and nonresettable
• 10 years data retention (without power)
over entire temperature range
• UL Recognized, CSA approved
• Pin termination .03 in diameter
• Hours from 0 to 99,999.9
• Counter from 0 to 999,999 pulses
• Voltages greater than 64 VDC
contact factory
* UL Listed, CSA Certified and CE Mark
** UL Recognized, CSA Certified and CE Mark
AC
APPLICATIO N S
• Business machines
• Air conditioning
• Furnaces
• Lab test equipment
• Sun tanning equipment
O p tions: If you need it, let us know.
YOUR satisfaction is our goal!
• Control panels
• Lighting systems
• Generators
• Compressors & pumps • Oxygen concentrators
• Refrigeration • Many more!
* Applicable on shown “screw terminal”
meters. Contact Hobbs for specifications
on other available models.
* Panel cutout dimensions are ± .010 tolerance
All dimensions shown in inches and (metric)
5
8
85000 Series
Quartz Plus DC Hour Meters
85000 Series Quartz Plus DC Hour Meters
DC
Th e 8 5 0 0 0 Se rie s provides legendary
Hobbs performance and reliability in a
technically advanced quartz package.
The Quartz Plus features a highly reliable
drive mechanism, an improved odometer
gear train, and a snap-together integrated
chassis. The chassis fits into a shockproof,
totally-sealed case made of an engineered
plastic that is impervious to acids and
solvents.
APPLICATIO N S
Ro u n d Ch ro m e Be ze l
• Lawn Tractors
• Garden Tractors
• Farm Equipment
• Gen Sets
• Construction
Equipment
• Utility Vehicles
• Industrial
Equipment
Part #
Flush Cup
2.27”
Part #
Stirrup
2.27”
Part #
Stirrup
2.50”
Part #
Flush Cup
2.50”
Operating
Voltage
10-32 VDC
10-80 VDC
30-110 VDC
85002
85342
85015
85006
85098
85019
85004
85008
2 Scre w
85017
85021
Operating
Voltage
Part #
6.5-16 VDC
10-32 VDC
10-80 VDC
30-110 VDC
85331
85000
85094
85013
To ensure our high standards of quality, all
parts are in-process inspected. Every
Quartz Plus meter must pass 100% function,
burn-in, and timing accuracy test before
shipping.
• Recreational
Vehicles
• Golf Carts
Ro u n d Bla ck Be ze l
Two-Screw Mount: Panel cutout
1.45 x.95 rectangular opening.
Two .150 holes spaced 1.750. *
Part #
Flush Cup
2.27”
Part #
Stirrup
2.27”
Part #
Stirrup
2.50”
Part #
Flush Cup
2.50”
• Aircraft
Operating
Voltage
• Medical Equipment
• Office Equipment
• Any application
requiring a very
accurate and
dependable hour
meter.
10-32 VDC
10-80 VDC
30-110 VDC
85003
85093
85016
85007
85099
85020
85005
85009
85022
Sp e cifica tio n s
• 10,000 hour version standard,
with automatic recycle to zero
• Temperature range: -40° F to +185° F
-40° C to +85° C
85018
• Quartz accuracy: ±200ppm, ±0.02%
(entire voltage and temperature range)
• Operating voltage range: 5-110 VDC
(Voltage range covered by 85000 Series line)
• Precision built relay driven odometer
• Excellent vibration & shock resistance:
Vibration: 20 g’s @ 10-80Hz (SAE J1378)
10 g’s (per MIL-M-3971)
3 Scre w
Operating
Voltage
Part #
Three-Screw Mount: Panel cutout
2.00 diameter opening. Three .150
holes equally spaced on 2.53 bolt
circle diameter.*
10-32 VDC
10-80 VDC
30-110 VDC
85001
85097
85014
Shock: 55 g’s @ 9-13msec (SAE J1378)
75 g’s (per MIL-M-3971)
• Transient Voltage Protection
Alternator load dump: 150V
EMI (Electromagnetic Interference): +400V @ 500Hz
Inductive switching and reverse polarity
• Standard terminals: 1/ 4” male blade
• Lens material: Glass
• Case material: Polyester
• Number size: 0.12” (3mm)
Flush Mount (Cup)
2.27”: Panel cutout
2.00 diameter opening.*
Flush Mount (Cup)
2.5”: Panel cutout
2.00 diameter opening.*
Flush Mount (Stirrup)
2.27”: Panel cutout
2.00 diameter opening.*
Flush Mount (Stirrup)
2.5”: Panel cutout
2.00 diameter opening.*
Re cta n g u la r Stirru p
Operating
Voltage
Part #
* Panel cutout dimensions are ± .010 tolerance
All dimensions shown in inches and (metric)
10-32 VDC
30-110 VDC
85010
85023
Fe a tu re s
8 5 0 0 0 Se rie s W irin g Dia g ra m s (Po la rity Se n sitive )
• Custom CMOS integrated circuit
• Indicates operating time in hours
and tenths, plus has a running indicator
• Totally-sealed
Rectangular Stirrup: Panel cutout
1.45 x .95 rectangular opening.*
+
+
• Battery system voltages:
6,12,24,36,48,60,72,and 80 VDC
• UL Recognized (File number AU1774)
• CSA Certified (File number LR42455-12)
• Conforms to MIL-M-3971
Re ta in e r Mo u n t
CAUTION: Always make sure power is removed from equipment before working on
electrical circuits! Only qualified personnel should make electrical connections.
Damage to equipment and/ or serious bodily injury can result from improperly made
electrical connections, or a failure to adhere to normal electrical safety guidelines
Operating
Voltage
O p tio n s:
Part #
Custom logos, polycarbonate lenses, and
various bezels. Wire, stud, blade, and
screw terminals. 100,000 hour, R-Terminal
and filtered versions available too.
6
10-32 VDC
10-80 VDC
82001
82320
* Panel cutout dimensions are ± .010 tolerance
All dimensions shown in inches and (metric)
Retainer Mount: Panel cutout
1.45 x .95 rectangular opening.*
7
相关型号: