2CLSA1B4-7 [HONEYWELL]

Snap Acting/Limit Switch;
2CLSA1B4-7
型号: 2CLSA1B4-7
厂家: Honeywell    Honeywell
描述:

Snap Acting/Limit Switch

开关
文件: 总6页 (文件大小:604K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Interactive Catalog Supplements Catalog PDFs  
If you need detailed product information, or help choosing the right  
product for your application, see our Interactive Catalogꢀ Use the  
Interactive Catalog to access the most complete and up-to-date  
information availableꢀ  
Sensing and Control  
In t e ra c t ive  
Ca t a lo g ...  
The Interactive Catalog provides an extensive collection of product  
specifications, application data, and technical literature that can be  
searched based on criteria you selectꢀ  
Click this icon to try  
the Interactive Catalogꢀ  
This PDF catalog information was published in November 2000ꢀ  
Sensing and Control  
Honeywell Incꢀ  
11 West Spring Street  
Freeport, IL 61032  
www.honeywell.com/sensing  
Limit and Enclosed Switches  
CLS Series  
Momentary Cable Pull Limit Switches: For Signaling Applications  
FEATURES  
ɀ Offered in Single Head and Duplex  
Head versions  
ɀ Optional direct acting contacts enhance  
reliability  
ɀ Duplex Head switches cover up to 400  
ft. cable spans (200 ft. in each direction)  
ɀ Single Head switches have one normally  
open auxiliary contact, while Duplex  
Head switches have up to three  
normally open and two normally closed  
auxiliary contacts  
ɀ Four conduit opening thread size  
options: 1/2-14 NPT, 20mm, PF1/2 and  
PG13.5  
ɀ Compact size of Single Head switches  
fits into tight spaces  
MOMENTARY (CONTACT SWITCH) OPERATING HEAD  
ɀ Sealed to NEMA 1, 3, 4 and 13  
ɀ Smart Distributed System output  
available on Duplex version for  
monitoring only  
Momentary CLS Series Cable Pull Limit Switches are designed for signaling applications;  
they are not to be used as emergency stop devices. (For emergency stop applications, see  
the Maintained Cable Pull Limit Switches in the Safety Products catalog.)  
ɀ UL listed  
Whenusingdirectactingcontacts,MomentaryCablePullLimitSwitchesprovideameansto  
manually force disconnection of a normally closed control circuit by pulling on an attached  
cable. Momentary switches cause contact transfer if the cable is manually pulled and held.  
When the cable is released, switch contacts return to their original state. Momentary  
switches have either direct-acting contacts or snap-action contacts.  
ɀ CSA certified  
ɀ CE certified  
ɀ Temperature range: –1° to 70°C (30° to  
158°F)  
ɀ Available with indicators  
ɀ Duplex versions available with high  
visibility pilot light  
Cable length may be up to 200 ft. in a straight line for Single Head switches, and up to 400 ft.  
(200 ft. in each direction) for Duplex Head switches.  
TYPICAL APPLICATIONS  
ɀ Conveyors  
ɀ Packaging machinery  
ɀ Assembly lines  
ɀ Process equipment  
ɀ Transfer lines  
TYPICAL DUPLEX HEAD SWITCH INSTALLATION  
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada  
A65  
Limit and Enclosed Switches  
CLS Series  
Momentary Cable Pull Limit Switches: For Signaling Applications  
TECHNICAL DATA CLS SERIES SPECIFICATIONS  
Electrical  
Rate thermal current  
Rate insulation voltage  
Impulse voltage  
I
th = 10 A  
Ui = 660 VAC/660 VDC  
imp = 2.5 kV  
< 25 milliohms  
U
Contact resistance  
Operating rating  
AC15  
U = 600 V: I = 1.2 A  
U = 240 V: I = 3 A  
U = 120 V: I = 6 A  
U = 250 V: I = 0.27 A  
U = 24 V: I = 2.8 A  
DC13  
UL/CSA  
A600/Q300  
Mechanical  
Protection class  
Mechanical life  
NEMA 1, 3, 4 and 13  
5
10 operations maximum  
Temperature Range  
Terminal identification  
Head/housing material  
–1° to 70°C (30° to 158°F)  
Numbering to EN50013  
Zinc die cast  
CABLE PULL SWITCH  
CHARACTERISTICS  
An additional auxiliary switch is also avail- SMART DISTRIBUTED SYSTEM OUTPUT  
able in the Duplex. This auxiliary switch may VERSION  
Momentary Cable Pull Limit Switches are be configured as 1NO - 1NC direct acting, The Smart Distributed System Output Ver-  
offered with a black operating head and a 2NO - 2NC snap action (monitoring only) or sion provides Smart Distributed System  
blue body. There is a choice of four different 1NO - 1NC with Smart Distributed System compatible switch status messaging. The  
conduit openings: 1/2-14 NPT, 20mm, PF output (monitoring only).  
1/2, and PG13.5. Duplex switches have 3  
primary contact block (NC) must be wired to  
the control current. The auxiliary contact  
block has been replaced with the Smart  
Distributed System circuitry.  
Neon and LED indicators are available. A  
standard conduit openings with two conduit  
plugs provided.  
6 watt incandescent pilot light is available  
on the Duplex for high visibility at long  
All switches come with a 1NO auxiliary con- distances.  
tact as standard.  
Snap action contact blocks and the Smart  
Distributed Output Version should be used  
for monitoring only. These types of switches  
should not be used in control circuits.  
A66  
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada  
Limit and Enclosed Switches  
CLS Series  
Momentary Cable Pull Limit Switches: For Signaling Applications  
SINGLE HEAD CLS ORDER GUIDE  
CLS  
BODY CODE  
MODIFICATION CODES  
A BLUE BODY – PG13.5  
B BLUE BODY – 1/2 NPT  
C BLUE BODY – 20MM  
D BLUE BODY – PF1/2  
1 HEAD ASSEMBLED WITH ACTUATOR TO THE LEFT  
2 HEAD ASSEMBLED WITH ACTUATOR TO THE FRONT  
3 HEAD ASSEMBLED WITH ACTUATOR TO THE  
MOUNTING SURFACE  
BASIC SWITCH CODE  
3 1NO-1NC SNAP ACTION (Monitoring Only)  
4 1NO-1NC DIRECT ACTING  
HEAD CODES  
B MOMENTARY  
5 1NO-1NC DIRECT ACTING 240V NEON INDICATOR  
6 1NO-1NC DIRECT ACTING 120V NEON INDICATOR  
7 1NO-1NC DIRECT ACTING 24V LED INDICATOR  
Notes:  
ɀ Leave the MODIFICATION CODE blank if a modification is not required.  
ɀ Standard head orientation is with actuator to the right.  
ɀ Unit may be field modified.  
EXAMPLE CATALOG LISTING  
Catalog Listing  
Description  
CLSD4B-1  
Single Head Cable Pull Limit Switch, Blue Body – PF 1/2, 1NO - 1NC  
Direct Acting, Momentary, Head assembled with actuator to the left  
DUPLEX HEAD 2CLS ORDER GUIDE  
2CLS  
BODY CODE  
MODIFICATION CODES  
(See chart below for numbered  
modification codes.)  
A BLUE BODY – PG13.5  
B BLUE BODY – 1/2 NPT  
C BLUE BODY – 20MM  
D BLUE BODY – PF1/2  
INDICATOR – PILOT LIGHT CODE  
A 120V – 6W RED PILOT LIGHT  
B 120V NEON INDICATOR  
C 240V NEON INDICATOR  
D 24V LED INDICATOR  
PRIMARY BASIC SWITCH CODE – LEFT  
1 1NO – 1NC DIRECT ACTING  
OPERATING HEAD  
B MOMENTARY, BOTH SIDES  
AUXILIARY BASIC SWITCH CODE – RIGHT  
1 1NO – 1NC DIRECT ACTING  
3 2NO – 2NC (DPDT) SNAP ACTION (Monitoring Only)  
4 1NO – 1NC WITH SDS OUTPUT (Monitoring Only)  
9 NO SWITCH  
Notes:  
HEAD ORIENTATION  
ɀ No numbered modification code indicates both heads oriented to side (Duplex Head).  
ɀ Standard Conduit openings are left, center, and right with two conduit plugs furnished.  
ɀ Leave the INDICATOR – PILOT LIGHT CODE blank if a pilot light is not required.  
NUMBERED MOD CODES  
MOD CODE LEFT HEAD RIGHT HEAD  
ɀ Leave the HEAD ORIENTATION NUMBERED MODIFICATION CODE blank if not required. Do not enter zero.  
1
2
3
4
5
6
7
8
FRONT  
FRONT  
FRONT  
REAR  
REAR  
REAR  
SIDE  
FRONT  
REAR  
SIDE  
EXAMPLE CATALOG LISTING  
Catalog Listing  
Description  
FRONT  
REAR  
SIDE  
2CLSB1B1-3  
Duplex Head Cable Limit Switch, Blue Body – 1/2 NPT, 1NO – 1NC  
Direct Acting, Momentary – Both Sides, 1NO – 1NC Direct Acting, No  
Pilot Light, Left Head Front – Right Head Side  
FRONT  
REAR  
SIDE  
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada  
A67  
Limit and Enclosed Switches  
CLS Series  
Momentary Cable Pull Limit Switches: For Signaling Applications  
MOUNTING DIMENSIONS  
(For reference only)  
A68  
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada  
Limit and Enclosed Switches  
CLS Series  
Momentary Cable Pull Limit Switches: For Signaling Applications  
INSTALLATION HARDWARE  
ɀ Aircraft cable precut to 25, 50, 100, 150  
and 200 feet lengths  
ɀ Lockout attachment  
ɀ End springs for long cable spans to  
compensate for temperature variations  
ɀ Installation hardware kit supports cable  
installations of 25 ft. and 50 ft.  
INSTALLATION HARDWARE ORDER GUIDE  
Catalog Listings  
CLSZC1  
Description  
25 ft. Red Aircraft Cable, finished cable dia. 0.187 in  
50 ft. Red Aircraft Cable, finished cable dia. 0.187 in  
100 ft. Red Aircraft Cable, finished cable dia. 0.187 in  
150 ft. Red Aircraft Cable, finished cable dia. 0.187 in  
200 ft. Red Aircraft Cable, finished cable dia. 0.187 in  
End Spring  
CLSZC2  
CLSZC3  
CLSZC4  
CLSZC5  
CLSZ1S  
CLSZ00  
Installation Kit includes: 4 thimbles, 8 wire rope clamps, 1 turnbuckle (w/lock nuts), 9 eyebolts (w/hardware),  
1 endspring, 1 conduit fitting  
Notes:  
1. Eyebolts should be spaced 1.8 to 2.4 m (6 to 8 ft.) apart.  
2. One used for each 7.5 m (25 ft.) of cable span.  
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada  
A69  

相关型号:

2CLSA1B4-8

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4A-3

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4A-5

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4B-3

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4B-4

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4C

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4C-2

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4C-3

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4C-4

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4C-5

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4D

Snap Acting/Limit Switch
HONEYWELL

2CLSA1B4D-4

Snap Acting/Limit Switch
HONEYWELL