2J1M14R-60 [HONEYWELL]

Analog Circuit;
2J1M14R-60
型号: 2J1M14R-60
厂家: Honeywell    Honeywell
描述:

Analog Circuit

文件: 总4页 (文件大小:184K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
21-75-03-06  
12/97  
Page 1 of 4  
Specification  
MegopaK Thermocouples  
Screw cover head  
Assembly with screw cover head  
0 0 1 - 1 5 9  
Miniature terminal block  
Assembly with insulated wire extension  
Miniature aluminum head  
Assembly with miniature aluminum head  
QuiK-Konnect plug and jack  
Assembly with armor cable extension  
Figure 1 — Megapak Assembles  
the basic combina-  
tion of wires, insulation, and pro-  
tecting sheath,  
A. Bulk Material –  
Function  
MegopaK Termocouple are used for  
sensing temperatures from –200° to  
1093°C (–300° to 2000°F).  
General purpose head  
Figure 2 — Terminations  
Elements - consisting of the basic  
combination with the wires welded  
to form a measuring junction (three  
types of junctions are available),  
B.  
C.  
Description  
Accessories  
Mounting attachments (compression fit-  
tings in 1/8, 1/4 or 1/2 inch NPT),  
MegopaK is a combination of thermo-  
couple wires, mineral insulation, and a  
Protecting sheath pressed into a solid  
mass of small diameter.  
Assemblies - complete thermocou-  
pies consisting of elements plus ter-  
minations (heads, plugs, jacks) and  
mounting attachments (Figures 1  
and 2).  
Brass or 316 stainless steel (not  
readjustable),  
These thermocouples are supplied in  
three forms:  
303 stainless steel (readjustable).  
Specification  
21-75-03-06  
Page 2  
Specifications  
Insulation Composition  
99% magnesium oxide (minimum); 0.001% boron.  
2 megohms at 500 Vdc for 7.62 metre (25 foot) length at room temperature.  
Insulation Resistance  
(minimum)  
Sheath Material  
Sheath Length  
Type 310, 316 or 446 stainless steel or Inconel.  
Any length up to 15.25 metres (50 foot) in increments of 25 mm (1 -inch).  
One sheath diameter (minimum).  
Bending Radius  
Speed of Response  
The time for test thermocouples to respond to 63.2°/0 of a step change in temperature.  
Speed of Response (Seconds)  
From Still Air at 93°C  
(200°F) to Still Air at  
815°C (1500°C)  
From Room Temp.  
to Salt Bath at  
427°C (800°F)  
Sheath Diameter  
From Room Temp.  
to 100°C (212°F)  
mm  
Type of Junction  
inch  
Integral  
(Grounded)  
0.063  
0.125  
0.188  
0.250  
0.375  
0.2  
0.7  
1.5  
1.7  
0.3  
1.1  
3.0  
3.8  
7.3  
9.0  
1.6  
3.2  
4.8  
6.4  
9.5  
16.0  
23.0  
32.3  
44.5  
2.8  
Exposed  
0.063  
0.125  
0.188  
0.250  
0.375  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.2  
0.2  
8.3  
1.6  
3.2  
4.8  
6.4  
9.5  
13.0  
21.0  
27.0  
27.5  
0.2  
1.6  
3.2  
4.8  
6.4  
9.5  
0.063  
0.125  
0.188  
0.250  
0.375  
0.8  
2.2  
0.8  
2.8  
7.8  
9.5  
17.6  
9.7  
Remote  
(Insulated)  
22.0  
31.5  
42.0  
76.0  
4.8  
7.8  
13.5  
Calibration Accuracy  
Type  
Limit of Error  
Limit of Error  
Temperature  
Range  
Temperature  
Range  
Type  
of Wire (whichever is greater)  
of Wire (whichever is greater)  
±1°C or ±1.5%  
±1°C or ±0.75%  
±1.5°F or ±2%  
±1.5°F or ±0.75%  
±1 .7°C or ±0.5%  
±3°F or ±0.5%  
Type T  
Type J  
–200 to 0°C  
0 to 350°C  
–300 to 32°F  
32 to 700°F  
Type E  
0 to 900°C  
32 to 1600° F  
±2.2°C or ±0.75%  
±4°F or ±0.75%  
0 to 1093°C  
32 to 2000° F  
Type K  
±2.2°C or ±0.75%  
±4°F or ±0.75%  
0 to 750°C  
32 to 1400°F  
NOTE: When the limit of error is given in % the percentage applies to the temperature being  
measured, not the range.  
Sheath Diameter  
Recommended Maximum  
Long-Term Service  
Temperatures  
9,5 mm  
(0.375”)  
6,4 mm  
(0.250”)  
4,8 mm  
(0.188”)  
3,2 mm  
(0.125”)  
1,6 mm  
(0.063”)  
Material  
371°F  
700°F  
315°C  
600°F  
Type T  
871°C  
871°C  
760°C  
760°C  
649°C  
Type J  
Type K  
Type E  
1600°F  
1600°F  
1400°F  
1400°F  
1200°F  
982°C  
1800°F  
982°C  
1800°F  
871°C  
1600°F  
871°C  
1600°C  
871°C  
1600°F  
927°C  
1700°F  
871°C  
1600°F  
Specification  
21-75-03-06  
Page 3  
Ordering Information  
2. For Thermocouple Elements,  
select model number from Table I  
followed by a letter selection from  
Table II plus desired length equal to  
the specified length plus 2 inches (51  
mm) of exposed bare thermocouple  
wire.  
Example: 2K3M22-R48 = Type K  
with Inconel sheath 4.8 mm (0.1 88”)  
diameter, remote junction and 48  
inches long.  
3. For Assemblies, select model  
number from Table I followed by a let-  
ter selection from Table II plus  
desired length of element in inches  
and the cold end termination  
designation from Table Ill. If mounting  
attachments and wire extension ter-  
minations are needed, make selec-  
tions from Tables IV and V. Select the  
required length of insulated extension  
wire in inches from Table VI.  
1. For Bulk MegopaK Material, select  
model number from Table 1, and  
specify length in inches. Longest  
length available depends on sheath  
diameter. Example: 2T1 Ml 5-60 =  
Type T with 316 SS sheath 1.6 mm  
(0.063”) diameter and 60 inches  
long.  
Example: 2J1Ml5-G24-9S-D12-  
3W2J36 = Type J with 316 SS  
sheath 1.6 mm (0.063”) diameter in-  
tegral junction, 24 inch sheath  
length, 12-inch wire extension length,  
316 SS compression fitting, 20 gauge  
insulated extension wire with fibre-  
glass insulation, QuiK-Konnect jack  
termination on extension wire.  
TABLE I - MEGOPAK BULK MATERIAL  
Sheath Diamter  
Element  
Sheath Material  
1.6 mm (0.063”)  
3.2 mm (0.125”)  
4.8 mm (0.188”)  
9.5 mm (0.375”)  
6.4 mm (0.250”)  
Type T  
316 Stainless Steel  
2T1M15  
2T2M15  
Inconel  
310 Stainless Steel  
316 Stainless Steel  
Type J  
Type J  
Type J  
Type J  
2J1M22  
2J1M14  
2J1M15  
2J2M22  
2J2M14  
2J3M22  
2J3M14  
2J6M22  
2J6M14  
2J6M15  
2J6M20  
2J4M22  
2J4M14  
2J4M15  
2J4M20  
2J2M15  
2J3M15  
446 Stainless Steel —  
Inconel  
310 Stainless Steel  
316 Stainless Steel  
Type K  
Type K  
Type K  
Type K  
2K6M22  
2K6M14  
2K6M15  
2K6M20  
2K1M22  
2K1M14  
2K1M15  
2K2M22  
2K2M14  
2K3M22  
2K3M14  
2K4M22  
2K4M14  
2K4M15  
2K4M20  
2K2M15  
2K3M15  
446 Stainless Steel –  
Type E  
316 Stainless Steel —  
2E3M15  
2E4M15  
Other types including special sheathing, 4 wire (duplex) type, and special calibrations are available on a special product  
basis. Consult Customer Service Department, Honeywell, Fort Washington, PA for complete information.  
TABLE II - TYPES OF MEASURING JUNCTIONS  
Specify  
Junction  
Symbol  
Description  
G *  
Junction welded to tip of sheath provides faster response time  
than Type R junction.  
E*  
Sheath end is left open. Wires are welded and exposed for a  
length of one sheath diameter. Sheath end is sealed with cement.  
Seal is effective up to 538°C (1OOO° F).  
Junction is insulated from sheath.  
R*  
*Add length in inches.  
Specification  
21-75-03-06  
Page 4  
TABLE IV - MOUNTING ATTACHMENTS  
(COMPRESSION FITTINGS)  
TABLE Ill - COLD END TERMINATIONS  
Specify  
Type  
Description  
Used With  
Tube Size  
-1  
Heads  
General Purpose Head with 1/2”  
NPT conduit connection  
Screw cover head with 1/2” NPT  
conduit connection  
Mounting  
Thread  
(NPT)  
inch  
mm  
-3  
Specify  
Material  
1/8  
1,6  
0.063  
R*  
Brass  
(not readjustable)  
-4  
Screw cover head with 3/4” NPT  
conduit  
Miniature Aluminum Head without  
mounting bushing  
Miniature Aluminum Head with  
1/4” NPT mounting bushing  
Miniature Terminal Block without  
mounting bushing  
3,2  
1/8  
1/8  
0.125  
0.188  
S*  
T†  
316 S.S.  
-11*  
12*  
-13*  
-14*  
(not readjustable) 4,8  
6,4  
9,5  
1/4  
1/2  
0.250  
0.375  
303 S.S.  
(readjustable).  
Terminal  
Block  
*Fitting is assembled loosely on sheath and can be adjusted as re-  
quired. After tightening, fitting cannot be relocated.  
†Fitting can be readjusted on sheath at any time.  
Miniature Terminal Block with  
1/4” NPT mounting bushing  
-5*  
TABLE V - WIRE EXTENSION TERMINATIONS  
QuiK-Konnect Plug  
QuiK-Konnect Jack  
Insulated Wire Extension  
Insulated Wire Extension, armored  
tubing  
Plug or  
Jack  
-6*  
-8†  
-9†  
Available only with  
Table Ill  
Insulated  
Wire  
Extension  
Designations  
Specify  
Description  
8,9,10  
A*  
No end terminal . . . wires  
bared 13 mm (0.5 in)  
-10†  
Insulated Wire Extension, with ar-  
mored tubing and junction box  
connector  
8,9,10  
8, 9  
8, 9  
B*  
C*  
D*  
Spade lug terminals  
QuiK-Konnect Plug  
QuiK-Konnect Jack  
*Not available with 9.5mm (0.375”) O.D. sheath.  
†These items require selections from Tables V and VI. Maximum  
temperature rating for standard transition sealant is 204°C  
(400°F).  
*Specify desired length of extension wire, in 152 mm (6-inch) in-  
crements. Minimum length: 305 mm (12 inches).  
INSULATED EXTENSION WIRE  
TABLE VI -  
Maximum Temperature  
Wire Size  
Ordering Number*  
Limits**  
(B&S  
Gauge)  
Qualifications  
°F  
°C  
105°  
Insulation  
Type E  
Type K  
Type T  
Type J  
20  
Underground; indoor  
or outdoor conduit;  
where exposed to oils,  
221°  
Polyvinyl over  
Polyvinyl  
1W2P6  
5W2P16  
3W2P6  
chemicals, acids, etc.  
24  
Not to be used in con-  
duits or out-of-doors  
-50 to  
320°  
-46 to  
160°  
Nylon  
9B1N4  
9B3N4  
AOOOO  
JOOOO  
w/Metal  
Braid  
ROOOO  
w/Armor  
20  
24  
Primarily for high  
temperature use  
482°  
900°  
400°  
Fibre Glass -  
Silicone  
Impregnated  
C0000  
LOOOO  
w/Metal  
Braid  
Resists most acids  
and vapors  
20  
204°  
Teflon  
TOOOO  
w/Armor  
*Specify length of wire required in inches.  
**These limits apply to the insulation of the wire extension. The temperature at the transition between thermocouple and wire  
extension, however, must not exceed 204°C (400°F) unless specifically requested.  
Specifications are subject to change without notice.  

相关型号:

2J1M15E-60

Analog Circuit
HONEYWELL

2J1M15G-60

Analog Circuit
HONEYWELL

2J1M15R-60

Analog Circuit
HONEYWELL

2J1M22E-60

Analog Circuit
HONEYWELL

2J1M22G-60

Analog Circuit
HONEYWELL

2J1M22R-60

Analog Circuit
HONEYWELL

2J2M14R-60

Analog Circuit
HONEYWELL

2J4B41

DIODE 2 A, 600 V, SILICON, BRIDGE RECTIFIER DIODE, Bridge Rectifier Diode
TOSHIBA

2J5001-5

RESISTOR, TEMPERATURE DEPENDENT, NTC, 5000 ohm, SURFACE MOUNT
VISHAY

2J55

Microwave Tubes and Solid-State Microwave Devices
ETC

2J6M15E-60

Analog Circuit
HONEYWELL

2J7001

RESISTOR, TEMPERATURE DEPENDENT, NTC, 7000 ohm, SURFACE MOUNT
VISHAY