21-75-03-06
12/97
Page 1 of 4
Specification
MegopaK Thermocouples
Screw cover head
Assembly with screw cover head
0 0 1 - 1 5 9
Miniature terminal block
Assembly with insulated wire extension
Miniature aluminum head
Assembly with miniature aluminum head
QuiK-Konnect plug and jack
Assembly with armor cable extension
Figure 1 — Megapak Assembles
the basic combina-
tion of wires, insulation, and pro-
tecting sheath,
A. Bulk Material –
Function
MegopaK Termocouple are used for
sensing temperatures from –200° to
1093°C (–300° to 2000°F).
General purpose head
Figure 2 — Terminations
Elements - consisting of the basic
combination with the wires welded
to form a measuring junction (three
types of junctions are available),
B.
C.
Description
Accessories
Mounting attachments (compression fit-
tings in 1/8, 1/4 or 1/2 inch NPT),
MegopaK is a combination of thermo-
couple wires, mineral insulation, and a
Protecting sheath pressed into a solid
mass of small diameter.
Assemblies - complete thermocou-
pies consisting of elements plus ter-
minations (heads, plugs, jacks) and
mounting attachments (Figures 1
and 2).
Brass or 316 stainless steel (not
readjustable),
These thermocouples are supplied in
three forms:
303 stainless steel (readjustable).
Specification
21-75-03-06
Page 2
Specifications
Insulation Composition
99% magnesium oxide (minimum); 0.001% boron.
2 megohms at 500 Vdc for 7.62 metre (25 foot) length at room temperature.
Insulation Resistance
(minimum)
Sheath Material
Sheath Length
Type 310, 316 or 446 stainless steel or Inconel.
Any length up to 15.25 metres (50 foot) in increments of 25 mm (1 -inch).
One sheath diameter (minimum).
Bending Radius
Speed of Response
The time for test thermocouples to respond to 63.2°/0 of a step change in temperature.
Speed of Response (Seconds)
From Still Air at 93°C
(200°F) to Still Air at
815°C (1500°C)
From Room Temp.
to Salt Bath at
427°C (800°F)
Sheath Diameter
From Room Temp.
to 100°C (212°F)
mm
Type of Junction
inch
Integral
(Grounded)
0.063
0.125
0.188
0.250
0.375
0.2
0.7
1.5
1.7
0.3
1.1
3.0
3.8
7.3
9.0
1.6
3.2
4.8
6.4
9.5
16.0
23.0
32.3
44.5
2.8
Exposed
0.063
0.125
0.188
0.250
0.375
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.2
8.3
1.6
3.2
4.8
6.4
9.5
13.0
21.0
27.0
27.5
0.2
1.6
3.2
4.8
6.4
9.5
0.063
0.125
0.188
0.250
0.375
0.8
2.2
0.8
2.8
7.8
9.5
17.6
9.7
Remote
(Insulated)
22.0
31.5
42.0
76.0
4.8
7.8
13.5
Calibration Accuracy
Type
Limit of Error
Limit of Error
Temperature
Range
Temperature
Range
Type
of Wire (whichever is greater)
of Wire (whichever is greater)
±1°C or ±1.5%
±1°C or ±0.75%
±1.5°F or ±2%
±1.5°F or ±0.75%
±1 .7°C or ±0.5%
±3°F or ±0.5%
Type T
Type J
–200 to 0°C
0 to 350°C
–300 to 32°F
32 to 700°F
Type E
0 to 900°C
32 to 1600° F
±2.2°C or ±0.75%
±4°F or ±0.75%
0 to 1093°C
32 to 2000° F
Type K
±2.2°C or ±0.75%
±4°F or ±0.75%
0 to 750°C
32 to 1400°F
NOTE: When the limit of error is given in % the percentage applies to the temperature being
measured, not the range.
Sheath Diameter
Recommended Maximum
Long-Term Service
Temperatures
9,5 mm
(0.375”)
6,4 mm
(0.250”)
4,8 mm
(0.188”)
3,2 mm
(0.125”)
1,6 mm
(0.063”)
Material
371°F
700°F
—
315°C
600°F
—
—
Type T
871°C
871°C
760°C
760°C
649°C
Type J
Type K
Type E
1600°F
1600°F
1400°F
1400°F
1200°F
982°C
1800°F
982°C
1800°F
871°C
1600°F
871°C
1600°C
871°C
1600°F
—
927°C
1700°F
871°C
1600°F
—
—
Specification
21-75-03-06
Page 3
Ordering Information
2. For Thermocouple Elements,
select model number from Table I
followed by a letter selection from
Table II plus desired length equal to
the specified length plus 2 inches (51
mm) of exposed bare thermocouple
wire.
Example: 2K3M22-R48 = Type K
with Inconel sheath 4.8 mm (0.1 88”)
diameter, remote junction and 48
inches long.
3. For Assemblies, select model
number from Table I followed by a let-
ter selection from Table II plus
desired length of element in inches
and the cold end termination
designation from Table Ill. If mounting
attachments and wire extension ter-
minations are needed, make selec-
tions from Tables IV and V. Select the
required length of insulated extension
wire in inches from Table VI.
1. For Bulk MegopaK Material, select
model number from Table 1, and
specify length in inches. Longest
length available depends on sheath
diameter. Example: 2T1 Ml 5-60 =
Type T with 316 SS sheath 1.6 mm
(0.063”) diameter and 60 inches
long.
Example: 2J1Ml5-G24-9S-D12-
3W2J36 = Type J with 316 SS
sheath 1.6 mm (0.063”) diameter in-
tegral junction, 24 inch sheath
length, 12-inch wire extension length,
316 SS compression fitting, 20 gauge
insulated extension wire with fibre-
glass insulation, QuiK-Konnect jack
termination on extension wire.
TABLE I - MEGOPAK BULK MATERIAL
Sheath Diamter
Element
Sheath Material
1.6 mm (0.063”)
3.2 mm (0.125”)
4.8 mm (0.188”)
9.5 mm (0.375”)
6.4 mm (0.250”)
—
—
Type T
316 Stainless Steel
2T1M15
2T2M15
–
Inconel
310 Stainless Steel
316 Stainless Steel
Type J
Type J
Type J
Type J
2J1M22
2J1M14
2J1M15
2J2M22
2J2M14
2J3M22
2J3M14
2J6M22
2J6M14
2J6M15
2J6M20
2J4M22
2J4M14
2J4M15
2J4M20
2J2M15
2J3M15
—
—
446 Stainless Steel —
Inconel
310 Stainless Steel
316 Stainless Steel
Type K
Type K
Type K
Type K
2K6M22
2K6M14
2K6M15
2K6M20
2K1M22
2K1M14
2K1M15
2K2M22
2K2M14
2K3M22
2K3M14
2K4M22
2K4M14
2K4M15
2K4M20
2K2M15
2K3M15
—
—
446 Stainless Steel –
—
Type E
316 Stainless Steel —
2E3M15
2E4M15
–
Other types including special sheathing, 4 wire (duplex) type, and special calibrations are available on a special product
basis. Consult Customer Service Department, Honeywell, Fort Washington, PA for complete information.
TABLE II - TYPES OF MEASURING JUNCTIONS
Specify
Junction
Symbol
Description
G *
Junction welded to tip of sheath provides faster response time
than Type R junction.
E*
Sheath end is left open. Wires are welded and exposed for a
length of one sheath diameter. Sheath end is sealed with cement.
Seal is effective up to 538°C (1OOO° F).
Junction is insulated from sheath.
R*
*Add length in inches.
Specification
21-75-03-06
Page 4
TABLE IV - MOUNTING ATTACHMENTS
(COMPRESSION FITTINGS)
TABLE Ill - COLD END TERMINATIONS
Specify
Type
Description
Used With
Tube Size
-1
Heads
General Purpose Head with 1/2”
NPT conduit connection
Screw cover head with 1/2” NPT
conduit connection
Mounting
Thread
(NPT)
inch
mm
-3
Specify
Material
1/8
1,6
0.063
R*
Brass
(not readjustable)
-4
Screw cover head with 3/4” NPT
conduit
Miniature Aluminum Head without
mounting bushing
Miniature Aluminum Head with
1/4” NPT mounting bushing
Miniature Terminal Block without
mounting bushing
3,2
1/8
1/8
0.125
0.188
S*
T†
316 S.S.
-11*
12*
-13*
-14*
(not readjustable) 4,8
6,4
9,5
1/4
1/2
0.250
0.375
303 S.S.
(readjustable).
Terminal
Block
*Fitting is assembled loosely on sheath and can be adjusted as re-
quired. After tightening, fitting cannot be relocated.
†Fitting can be readjusted on sheath at any time.
Miniature Terminal Block with
1/4” NPT mounting bushing
-5*
TABLE V - WIRE EXTENSION TERMINATIONS
QuiK-Konnect Plug
QuiK-Konnect Jack
Insulated Wire Extension
Insulated Wire Extension, armored
tubing
Plug or
Jack
-6*
-8†
-9†
Available only with
Table Ill
Insulated
Wire
Extension
Designations
Specify
Description
8,9,10
A*
No end terminal . . . wires
bared 13 mm (0.5 in)
-10†
Insulated Wire Extension, with ar-
mored tubing and junction box
connector
8,9,10
8, 9
8, 9
B*
C*
D*
Spade lug terminals
QuiK-Konnect Plug
QuiK-Konnect Jack
*Not available with 9.5mm (0.375”) O.D. sheath.
†These items require selections from Tables V and VI. Maximum
temperature rating for standard transition sealant is 204°C
(400°F).
*Specify desired length of extension wire, in 152 mm (6-inch) in-
crements. Minimum length: 305 mm (12 inches).
INSULATED EXTENSION WIRE
TABLE VI -
Maximum Temperature
Wire Size
Ordering Number*
Limits**
(B&S
Gauge)
Qualifications
°F
°C
105°
Insulation
Type E
Type K
Type T
Type J
20
Underground; indoor
or outdoor conduit;
where exposed to oils,
221°
Polyvinyl over
Polyvinyl
1W2P6
5W2P16
—
3W2P6
chemicals, acids, etc.
24
Not to be used in con-
duits or out-of-doors
-50 to
320°
-46 to
160°
Nylon
9B1N4
—
—
—
9B3N4
AOOOO
JOOOO
w/Metal
Braid
ROOOO
w/Armor
20
24
Primarily for high
temperature use
482°
900°
400°
Fibre Glass -
Silicone
Impregnated
C0000
LOOOO
w/Metal
Braid
—
Resists most acids
and vapors
20
204°
Teflon
TOOOO
w/Armor
*Specify length of wire required in inches.
**These limits apply to the insulation of the wire extension. The temperature at the transition between thermocouple and wire
extension, however, must not exceed 204°C (400°F) unless specifically requested.
Specifications are subject to change without notice.