64AT203-3G [HONEYWELL]

Toggle Switch, 4PDT, Latched, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded;
64AT203-3G
型号: 64AT203-3G
厂家: Honeywell    Honeywell
描述:

Toggle Switch, 4PDT, Latched, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded

开关 光电二极管
文件: 总11页 (文件大小:585K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MICRO SWITCH™ Commercial-Grade Toggle Switches  
AT Series  
005435  
Issue 1  
Datasheet  
FEATURES  
• Assemblies available as MIL-PRF-8805 qualified or the  
individual basic switches with UL, CSA, and CE certification  
• 2- or 3-position, momentary and maintained action  
• Up to 10 SPDT precision basic switches  
• Short behind-panel depth  
• Choice of 1⁄4- or 15/32-inch bushings  
• Silver or gold contacts  
• Lever lock options  
Toggle lever and panel seal options  
• Electrical connections: screw, solder, quick connect (blade),  
and preleaded  
DESCRIPTION  
POTENTIAL APPLICATIONS  
• Aircraft (commercial and military)  
• Military ground vehicles  
• Flight controls  
Honeywell’s MICRO SWITCH™ AT toggle switches provide  
a compact multi-pole toggle switch with a long history of  
successful performance, exceeding 50 years. The AT Toggle  
Switch Series is available as a 1-, 2-, 3-, 4-, 6-, 8-, or 10-pole  
design for a wide range of applications with a metal toggle  
lever, metal bushing, and metal housing for durability. Select AT  
Series are qualified to MIL-PRF-8805 for military applications.  
For applications which do not require a military approved switch,  
there are other AT Series switches for commercial and industrial  
applications.  
• Vehicle panel controls  
PORTFOLIO  
Honeywell offers six series of MICRO SWITCH™ toggle switches  
including the TL Series, NT Series, TS Series, TW Series, and ET  
Series.  
Options for the AT Series include panel seals and lever-to-  
bushing seals. These options enhance product performance  
where environments of dust or water spray could be present in  
the application. Complementing the product offering, MICRO  
SWITCH™ AT toggle switch assemblies are available with  
individual poles (basic switches) which are UL, CSA, and CE  
certified.  
VALUE TO CUSTOMERS  
• Multi-pole, multi-throw circuitry (up to 10 pole) for controlling  
independent circuits or providing redundant circuit capability  
• Flexible insulators between poles minimize electrical bridging  
• MIL-PRF-8805 qualified switches  
• Reduces service costs  
• Extends equipment life  
• Front of panel sealing available  
DIFFERENTIATION  
• Only manufacturer with 10-pole circuitry  
• Utilizes proven and reliable snap-action switch design  
Sensing and Productivity Solutions  
MICRO SWITCH™ Commercial-Grade Toggle Switches, AT Series  
Table 1. Specifications  
Characteristic  
Description  
Actuators  
Parameter  
Commercial-grade toggle switch; military-qualified toggle switches available  
Standard lever, locking lever, tab lever, special lever  
2- or 3-position with maintained or momentary action  
Panel mount threaded bushing; Ø 1/4 in [0.25] or 15/32 in [0.47]  
Lever action  
Mounting  
Ø 1/4 in [0.25 in] bushing 1-, 2-, or 3-single pole double throw (SPDT) basics;  
Ø15/32 in [0.47 in] bushing 2-, 4-, 6-, 8-, or 10-single pole double throw (SPDT) basics  
Bushing  
Termination  
Solder thru-hole; solder single turret; solder double turret; screw; quick-connect blade; pre-leaded  
Silver alloy or gold-plated silver alloy  
Contact material  
Electrical rating  
30 Vdc; 125 Vac; 250 Vac (See Tables 2 & 3)  
Electrical endurance  
(commercial grade)  
6,000 cycles min.  
25,000 cycles min.  
Electrical endurance  
(military qualified)  
Sealing  
Unsealed; lever-to-bushing seal; panel seal & lever-to-bushing seal  
-55 °C to 85 °C [-67 °F to 185 °F]  
Operating temperature  
Available as MIL-PRF-8805; or UL, CSA, CE [individual basic switches]  
Select catalog listings with FAA-PMA  
Approvals  
Table 2. 6AT/13AT/23AT Series with MICRO SWITCH™ SM type basic switch electrical ratings (amps)  
Sea Level  
Altitude 50,000 ft  
Resistive  
UL/CSA/CE  
rating for  
SM basic switch  
Supply voltage  
(contact material)  
Inrush @ 30  
Vdc [max.]  
Inrush @  
30 Vdc max.  
Resistive  
Inductive  
Inductive  
2.5  
30 Vdc  
(silver contacts)  
24  
2
5
1
3
24  
2
5
1
30 Vdc  
(gold contacts)  
0.5  
0.5  
125 Vac, UL/CSA  
250 Vac, CE  
(gold contacts)  
1
5
250 Vac  
(silver contacts)  
Table 3. 60AT Series with MICRO SWITCH™ SX type basic switch electrical ratings (amps)  
UL/CSA/CE  
rating for  
SX basic switch  
Sea Level  
Altitude 50,000 ft  
Supply voltage  
(contact material)  
Resistive  
Inductive  
Resistive  
Inductive  
28 Vdc  
(silver contacts)  
7
7
7
4
7
4
2.5  
115 Vac, 60 Hz  
(silver contacts)  
250 Vac  
(silver contacts)  
2
sensing.honeywell.com  
MICRO SWITCH™ Commercial-Grade Toggle Switches, AT Series  
Figure 1. MICRO SWITCH™ AT Series Locking Configurations  
Figure 5. 62AT Series (2PDT)  
TERMINAL CIRCUIT IDENTIFICATION  
2-Pole  
(BOTTOM VIEW)  
1
2
NC • NO • C  
NC • NO • C  
Terminal markings (electrical connections) are identified in the  
order guide section with a C (for common), NC (for normally  
closed), and NO (for normally open). In addition, the poles (basic  
switches) of the AT toggle switch are identified with a number  
marked on the end of the basic switch (i.e. a four pole switch will  
have each pole (basic switch) marked 1, 2, 3, or 4 on the end of  
each basic switch.  
Keyway  
Figure 6. 64AT Series (4PDT)  
1
2
NC • NO • C  
NC • NO • C  
3
4
C • NO • NC  
C • NO • NC  
Key-  
way  
Figure 7. 66AT Series (6PDT)  
Figure 2. 6AT Series with 1PDT, 2PDT, or 3PDT  
1
2
3
NC • NO • C  
NC • NO • C  
NC • NO • C  
4
5
6
C • NO • NC  
C • NO • NC  
C • NO • NC  
Key-  
way  
1-Pole  
2-Pole  
3-Pole  
C • NO • NC  
C • NO • NC  
C • NO • NC  
C • NO • NC  
C • NO • NC  
C • NO • NC  
Key tab or  
keyway  
Figure 8. 68AT Series (8PDT)  
1
2
3
4
NC • NO • C  
NC • NO • C  
NC • NO • C  
NC • NO • C  
5
6
7
8
C • NO • NC  
C • NO • NC  
C • NO • NC  
C • NO • NC  
Key-  
way  
Figure 3. 13AT Series with 2PDT, 3PDT, or 4PDT  
2-Pole  
3-Pole  
4-Pole  
2
1
C • NO • NC  
NC • NO • C  
3
2
1
NC • NO • C  
C • NO • NC  
NC • NO • C  
4
3
2
1
NC • NO • C  
C • NO • NC  
C • NO • NC  
NC • NO • C  
Key-  
way  
Figure 4. 23AT Series with 2PDT, 3PDT, or 4PDT  
2-Pole  
3-Pole  
4-Pole  
C • NO • NC  
C • NO • NC  
C • NO • NC  
C • NO • NC  
C • NO • NC  
C • NO • NC  
C • NO • NC  
C • NO • NC  
C • NO • NC  
Keyway  
Sensing and Productivity Solutions  
3
MICRO SWITCH™ Commercial-Grade Toggle Switches, AT Series  
13AT SERIES THREE-POSITION ORDER GUIDE  
Table 4. Three-Position 13AT Series  
Metal Tab  
Lever  
Pull-to-unlock  
Toggle Lever Position  
Standard Lever  
Lever  
Solder  
Termination  
No Suffix  
(thru-hole), -T  
Suffix (turrent), Suffix (double  
Solder  
Termination  
with -T2  
No. of  
Poles/  
Basic  
Add Lever  
Lock Suffix to  
Cat. Listing  
Below  
Lever-  
Lock  
Opposite  
Keyway  
Contact  
Material  
Keyway  
Center  
Suffix1  
Switches  
-T2 Suffix  
turrent)  
(double turrent)  
Both  
Poles,  
C-NC  
All lever  
lock  
types  
Pole 1, C-NC  
Pole 2, C-NO  
Pole 1, C-NO  
Pole 2, C-NC  
13AT2,  
13AT2-T  
2
2
Silver  
Silver  
13AT402-T2  
13AT2-  
Lever  
lock  
types  
E, G,  
B, L, N,  
or P  
Both  
Poles,  
C-NC  
Pole 1, C-NC  
Pole 2, C-NO  
Pole 1*, C-NO  
Pole 2*, C-NC  
13AT3  
Lever  
lock  
types E,  
L, or N  
Both  
Poles,  
C-NC  
Pole 1*, C-NC  
Pole 2*, C-NO  
Pole 1*, C-NO  
Pole 2*, C-NC  
13AT1,  
13AT1-T  
2
2
4
Silver  
Gold  
Silver  
13AT401-T2  
13AT1-  
Lever  
lock  
types E,  
L, or N  
Both  
Poles,  
C-NC  
Pole 1*, C-NC  
Pole 2*, C-NO  
Pole 1*, C-NO  
Pole 2*, C-NC  
13AT26  
Pole 1, C-NC  
Pole 1, C-NO  
Pole 2, C-NC  
Pole 3, C-NC  
Pole 4, C-NO  
All lever  
lock  
types  
Pole 2, C-NO All Poles,  
13AT9-T2  
13AT9-  
Pole 3, C-NO  
Pole 4, C-NC  
C-NC  
Lever  
lock  
types  
E, G,  
B, L, N,  
or P  
Pole 1, C-NC  
Pole 2, C-NO All Poles,  
Pole 3, C-NO  
Pole 4, C-NC  
Pole 1*, C-NO  
Pole 2*, C-NC  
Pole 3*, C-NC  
Pole 4*, C-NO  
4
4
Silver  
Silver  
13AT10  
13AT8  
C-NC  
Pole 1*, C-NC  
Pole 2*, C-NO All Poles,  
Pole 3*, C-NO  
Pole 4*, C-NC  
Pole 1*, C-NO  
Pole 2*, C-NC  
Pole 3*, C-NC  
Pole 4*, C-NO  
Lever  
lock  
types E,  
L, or N  
13AT8-  
C-NC  
* These positions are momentary. All other positions are maintained  
C = Common Terminal; NC = Normally Closed Terminal; NO = Normally Open Terminal  
1 See page 3 for lever lock configurations  
4
sensing.honeywell.com  
MICRO SWITCH™ Commercial-Grade Toggle Switches, AT Series  
13AT SERIES THREE-POSITION ORDER GUIDE  
Table 5. Three-Position MIL-PRF-8805 13AT Catalog listings  
Standard Lever  
Solder Termination  
-T2 Suffix (double  
turrent)  
Metal Tab Lever  
Solder Termination  
-T2 Suffix (double  
turrent)  
Toggle Lever Position  
Pull-to-Unlock Lever1  
No. of  
Poles/  
Basic  
Military  
Catalog  
Military  
Catalog  
Military  
Catalog  
Opposite Contact  
Keyway Material  
Keyway Center  
Part  
Part  
Part  
Listing  
Listing  
Listing  
Number  
Number  
Number  
Switches  
Pole 1,  
Both  
Pole 1,  
C-NO  
Pole 2,  
C-NC  
13AT272- M8805/92-  
C-NC  
Poles,  
Pole 2,  
C-NC  
C-NO  
M8805/26-  
13AT272-T2  
T2-A  
006  
2
2
2
Silver  
007  
13AT272- M8805/92-  
T2-M  
014  
Pole 1,  
Both  
Pole 1*,  
C-NO  
Pole 2*,  
C-NC  
C-NC  
Poles,  
Pole 2,  
C-NC  
C-NO  
M8805/26-  
13AT273-T2  
Silver  
009  
Pole 1*,  
Both  
Pole 1*,  
C-NO  
Pole 2*,  
C-NC  
C-NC  
Poles,  
Pole 2*,  
C-NC  
C-NO  
M8805/26-  
13AT271-T2  
M8805/26- 13AT271- M8805/92-  
Silver  
13AT471-T2  
005  
006  
T2-E  
005  
Pole 1,  
Pole 1*,  
C-NO  
Pole 2*,  
C-NC  
Pole 3*,  
C-NO  
C-NC  
All  
Pole 2,  
Poles,  
C-NO  
C-NC  
Pole 3,  
M8805/26-  
13AT275-T2  
M8805/26-  
014  
3
Silver  
13AT475-T2  
013  
C-NC  
* These positions are momentary. All other positions are maintained  
C = Common Terminal; NC = Normally Closed Terminal; NO = Normally Open Terminal  
1 See page 3 for lever lock configurations  
Sensing and Productivity Solutions  
5
MICRO SWITCH™ Commercial-Grade Toggle Switches, AT Series  
23AT SERIES TWO-POSITION ORDER GUIDE  
Table 6. Two-Position 23AT Series  
Toggle Lever Position  
Standard Lever  
Metal Tab Lever  
Pull-to-unlock Lever  
No. of  
Poles/  
Basic  
Solder Termination  
No Suffix (thru-  
hole), -T2 Suffix  
(double turrent)  
Solder Termination  
with -T2 Suffix  
(double turrent)  
Add Lever Lock  
Suffix to Cat. Listing  
below  
Opposite  
Keyway  
Contact  
Material  
Lever-lock  
Suffix1  
Keyway  
Switches  
C-NO ea  
Pole  
C-NC ea  
Pole  
2
2
2
2
3
3
4
4
4
Silver  
Gold  
Silver  
Gold  
Silver  
Silver  
Silver  
Gold  
Silver  
23AT1, 23AT1-T2  
23AT11, 23AT11-T2  
23AT4, 23AT4-T2  
23AT19  
23AT402-T2  
23AT1-  
D, F, or G  
C-NO ea  
Pole  
C-NC ea  
Pole  
23AT1-  
D, F, or G  
C-NO ea  
Pole*  
C-NC ea  
Pole  
23AT403-T2  
C-NO ea  
Pole*  
C-NC ea  
Pole  
C-NO ea  
Pole  
C-NC ea  
Pole  
23AT2, 23 AT2-T2  
23AT5  
23AT2-  
D, F, or G  
C-NO ea  
Pole*  
C-NC ea  
Pole  
C-NO ea  
Pole  
C-NC ea  
Pole  
23AT3, 23AT-T2  
23AT8  
23AT3-  
D, F, or G  
C-NO ea  
Pole  
C-NC ea  
Pole  
C-NO ea  
Pole*  
C-NC ea  
Pole  
23AT6, 23AT6-T2  
* These positions are momentary. All other positions are maintained  
1 See page 3 for lever lock configurations  
23AT SERIES TWO-POSITION ORDER GUIDE  
Table 7. Two-Position MIL-PRF-8805 23AT Catalog listings  
Standard Lever  
Solder Termination  
-T2 Suffix (double turrent) -T2 Suffix (double turrent)  
Metal Tab Lever  
Solder Termination  
Toggle Lever  
Position  
Pull-to-Unlock Lever1  
No. of  
Poles/  
Basic  
Military  
Part  
Number  
Military  
Part  
Number  
Military  
Catalog  
Opposite Contact  
Catalog  
Listing  
Catalog  
Listing  
Keyway  
Part  
Keyway  
Material  
Listing  
Number  
Switches  
C-NO ea  
Pole  
C-NC ea  
Pole  
M8805/26-  
001  
M8805/26-  
003  
23AT73-  
T2-D  
M8805/92-  
001  
23AT73-T2  
23AT74-T2  
23AT473-T2  
2
4
4
Silver  
Silver  
Silver  
C-NO ea  
Pole  
C-NC ea  
Pole  
M8805/26-  
002  
23AT74-  
T2-D  
M8805/92-  
002  
C-NO ea  
Pole  
C-NC ea  
Pole  
23AT74-  
T2-G  
M8805/92-  
004  
* These positions are momentary. All other positions are maintained  
1 See page 3 for lever lock configurations  
6
sensing.honeywell.com  
MICRO SWITCH™ Commercial-Grade Toggle Switches, AT Series  
6AT SERIES TWO-POSITION ORDER GUIDE  
Table 8. Two-Position 6AT Series  
Toggle Lever Position  
Standard Lever  
Solder Termination  
No Suffix (thru-hole),  
-T Suffix (turrent)  
No. of Poles/  
Basic Switches  
Opposite  
Keyway  
Contact  
Material  
Bushing Size  
Keyway  
1
1
2
2
3
C-NO  
C-NC  
Silver  
Gold  
Silver  
Gold  
Silver  
6AT2; 6AT2-T  
6AT23  
C-NO  
C-NC  
1/4 (0.25) inch Ø bushing with key  
tab  
C-NO ea Pole  
C-NO ea Pole  
C-NO ea Pole  
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
6AT3; 6AT3-T  
6AT13  
6AT501; 6AT501-T  
1
2
C-NO  
C-NO  
C-NC  
C-NC  
Silver  
Silver  
6AT1; 6AT1-T  
6AT4  
1/4 (0.25) inch Ø bushing without  
key tab  
1
1
2
2
3
C-NO  
C-NC  
Silver  
Gold  
Silver  
Gold  
Silver  
6AT6  
6AT17  
C-NO  
C-NC  
15/32 (0.47) inch Ø bushing with  
key washer  
C-NO ea Pole  
C-NO ea Pole  
C-NO ea Pole  
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
6AT7  
6AT42  
6AT10; 6AT10-T  
* These positions are momentary. All other positions are maintained  
60AT SERIES TWO-POSITION ORDER GUIDE  
Table 9. Two-Position 60AT Series  
Toggle Lever Position  
Standard Lever  
Standard Lever  
Pull-to-unlock Lever1  
Mil-S-6743  
Basic Switches  
MIL-PRF-8805/4  
Basic Switches  
Add Lever Lock Suffix  
"Letter" to Cat. Listing  
No. of Poles/  
Basic Switches  
Keyway  
Opposite Keyway  
2
2
C-NC ea Pole  
C-NC ea Pole  
C-NO ea Pole  
C-NO ea Pole*  
62AT11-3  
-
62AT22-3  
D, G  
G
62AT22-82  
C-NC Pole 1,2;  
C-NO Pole 3,4  
C-NC Pole 3,4;  
C-NO Pole 1,2  
4
6
8
64AT11-3  
66AT11-3  
64AT22-3  
66AT22-3  
68AT22-3  
D, F, G  
D, F, G  
D, F, G  
C-NC Pole 1,2,3;  
C-NO Pole 4,5,6  
C-NC Pole 4,5,6;  
C-NO Pole 1,2,3  
C-NC Pole 1,2,3,4; C-NC Pole 5,6,7,8;  
C-NO Pole 5,6,7,8 C-NO Pole 1,2,3,4  
* These positions are momentary. All other positions are maintained  
1 See page 3 for lever lock configurations  
Sensing and Productivity Solutions  
7
MICRO SWITCH™ Commercial-Grade Toggle Switches, AT Series  
60AT SERIES TWO-POSITION ORDER GUIDE  
Table 10. Two-position 60AT Series per MIL-PRF-8805/98 (with Bushing and Panel Seals)  
Pull-to-Unlock  
Lever1  
Pull-to-Unlock  
Lever1  
Toggle Lever Position  
Standard Lever Standard Lever  
Add Lever Lock  
Suffix "Letter"  
to Standard  
Lever TOggle  
Switch  
No. of Poles/  
Basic Switches  
Military  
Number  
Military  
Number  
Keyway  
Opposite Keyway Catalog Listing  
C-NC Pole 1,2;  
C-NO Pole 3,4  
C-NC Pole 3,4;  
C-NO Pole 1,2  
4
6
8
64AT300-3  
66AT300-3  
68AT300-3  
M8805/98-015  
M8805/98-046  
M8805/98-077  
D, F, G  
D, F, G  
D, F, G  
M8805/98-**  
M8805/98-**  
M8805/98-**  
C-NC Pole 1,2,3;  
C-NO Pole 4,5,6  
C-NC Pole 4,5,6;  
C-NO Pole 1,2,3  
C-NC Pole 1,2,3,4; C-NC Pole 5,6,7,8;  
C-NO Pole 5,6,7,8 C-NO Pole 1,2,3,4  
** Add the appropriate 3 digit suffix to the military number  
1 See page 3 for lever lock configurations  
60AT SERIES THREE-POSITION ORDER GUIDE  
Table 11. Three-Position 60AT Series  
Pull-to-Inlock  
Lever1  
Toggle Lever Position  
Standard Lever  
Standard Lever  
No. of  
Poles/  
Basic  
Add Lever Lock  
Suffix Options to  
Cat. Listing  
Mil-S-6743  
Basic Switches  
MIL-PRF-8805/4  
Basic Switches  
Keyway  
Center  
Opposite Keyway  
Switches  
C-NC Pole 1,2;  
C-NO Pole 3,4  
C-NC Pole 3,4;  
C-NO Pole 1,2  
All lever lock  
options  
4
4
4
4
6
6
6
6
8
8
8
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
C-NC ea Pole  
64AT11-1  
64AT11-5  
-
64AT22-1  
64AT22-5  
64AT22-514  
64AT22-7  
66AT22-1  
66AT22-5  
C-NC Pole 1,2;*  
C-NO Pole 3,4*  
C-NC Pole 3,4;  
C-NO Pole 1,2  
E,F,K,L,M,N  
B,E,G,L,N,P  
E,L,N  
C-NC Pole 1,2;  
C-NO Pole 3,4  
C-NC Pole 3,4;*  
C-NO Pole 1,2*  
C-NC Pole 1,2;*  
C-NO Pole 3,4*  
C-NC Pole 3,4;*  
C-NO Pole 1,2*  
64AT11-7  
66AT11-1  
66AT11-5  
66AT11-514  
66AT11-7  
68AT11-1  
68AT11-5  
68AT11-7  
C-NC Pole 1,2,3;  
C-NO Pole 4,5,6  
C-NC Pole 4,5,6;  
C-NO Pole 1,2,3  
All lever lock  
options  
C-NC Pole 1,2,3;*  
C-NO Pole 4,5,6*  
C-NC Pole 4,5,6;  
C-NO Pole 1,2,3  
E,F,K,L,M,N  
B,E,G,L,N,P  
E,L,N  
C-NC Pole 1,2,3;  
C-NO Pole 4,5,6  
C-NC Pole 4,5,6;*  
C-NO Pole 1,2,3*  
C-NC Pole 1,2,3;*  
C-NO Pole 4,5,6*  
C-NC Pole 4,5,6;*  
C-NO Pole 1,2,3*  
66AT22-7  
68AT22-1  
68AT22-5  
68AT22-7  
C-NC Pole 1,2,3,4;  
C-NO Pole 5,6,7,8  
C-NC Pole 5,6,7,8;  
C-NO Pole 1,2,3,4  
All lever lock  
options  
C-NC Pole 1,2,3,4;*  
C-NO Pole 5,6,7,8*  
C-NC Pole 5,6,7,8;  
C-NO Pole 1,2,3,4  
E,F,K,L,M,N  
E,L,N  
C-NC Pole 1,2,3,4;*  
C-NO Pole 5,6,7,8*  
C-NC Pole 5,6,7,8;*  
C-NO Pole 1,2,3,4*  
* These positions are momentary. All other positions are maintained  
1 See page 3 for lever lock configurations  
8
sensing.honeywell.com  
MICRO SWITCH™ Commercial-Grade Toggle Switches, AT Series  
60AT SERIES THREE-POSITION ORDER GUIDE  
Table 12. Three-position 60AT Series per MIL-PRF-8805/98 (with Bushing and Panel Seals)  
Standard  
Lever  
Standard  
Lever  
Pull-to-Un-  
lock Lever1  
Pull-to-Un-  
lock Lever1  
Toggle Lever Position  
Add Lever  
Lock Suffix  
"Letter" to  
Standard  
No. of  
Poles/  
Basic  
Catalog  
Listing  
Military  
Number  
Military  
Number  
Keyway  
Center  
Opposite Keyway  
Switches  
Lever Toggle  
Switch  
C-NC Pole 1,2;  
C-NO Pole 3,4  
C-NC ea  
Pole  
C-NC Pole 3,4  
C-NO Pole 1,2  
M8805/98-  
001  
All lever lock  
types  
4
4
4
6
6
6
8
8
64AT300-1  
64AT300-5  
64AT300-7  
66AT300-1  
66AT300-5  
-
M8805/98-**  
C-NC Pole 1,2;*  
C-NO Pole 3,4*  
C-NC ea  
Pole  
C-NC Pole 3,4  
C-NO Pole 1,2  
M8805/98-  
019  
E,F,K,L,M,N M8805/98-**  
C-NC Pole 1,2;*  
C-NO Pole 3,4*  
C-NC ea  
Pole  
C-NC Pole 3,4;*  
C-NO Pole 1,2*  
M8805/98-  
026  
E,L,N  
M8805/98-**  
M8805/98-**  
C-NC Pole 1,2,3;  
C-NO Pole 4,5,6  
C-NC ea  
Pole  
C-NC Pole 4,5,6;  
C-NO Pole 1,2,3  
M8805/98-  
032  
All lever lock  
types  
C-NC Pole 1,2,3;*  
C-NO Pole 4,5,6*  
C-NC ea  
Pole  
C-NC Pole 4,5,6;  
C-NO Pole 1,2,3  
M8805/98-  
050  
E,F,K,L,M,N M8805/98-**  
C-NC Pole 1,2,3;*  
C-NO Pole 4,5,6*  
C-NC ea  
Pole  
C-NC Pole 4,5,6;*  
C-NO Pole 1,2,3*  
M8805/98-  
057  
66AT300-7+  
M8805/98-**  
E,L,N  
C-NC Pole 1,2,3,4;  
C-NO Pole 5,6,7,8  
C-NC ea  
Pole  
C-NC Pole 5,6,7,8;  
C-NO Pole 1,2,3,4  
M8805/98-  
063  
All lever lock  
M8805/98-**  
types  
68AT300-5+  
M8805/98-**  
E,F,K,L,M,N  
68AT300-1  
-
C-NC Pole 1,2,3,4;*  
C-NO Pole 5,6,7,8*  
C-NC ea  
Pole  
C-NC Pole 5,6,7,8;  
C-NO Pole 1,2,3,4  
M8805/98-  
081  
C-NC Pole 1,2,3,4;*  
C-NO Pole 5,6,7,8*  
C-NC ea  
Pole  
C-NC Pole 5,6,7,8;*  
C-NO Pole 1,2,3,4*  
M8805/98-  
092  
68AT300-7+  
M8805/98-**  
E,L,N  
8
-
* Momentary position. All other positions are maintained.  
** Add the appropriate 3 digit suffix to the military number  
+ Add the lever lock “letter” to the base catalog listing  
1 See page 3 for lever lock configurations  
Sensing and Productivity Solutions  
9
MICRO SWITCH™ Commercial-Grade Toggle Switches, AT Series  
DIMENSIONAL DRAWINGS  
Figure 9. 13/23AT Series, Standard Lever  
Figure 14. 62AT Series, Standard Lever  
Figure 10. 13/23AT Series, Tab Lever  
Figure 15. 64/66/68AT Series, Locking Lever  
Figure 11. 13/23AT Series, Locking Lever  
Figure 16. Panel Cutouts  
Figure 12. 6AT Series, with Keying Washer  
Figure 13. 6AT Series, Bushing with Key Tab  
10 sensing.honeywell.com  
m WARNING  
ADDITIONAL MATERIALS  
PERSONAL INJURY  
The following associated literature is available on the Honeywell  
web site at sensing.honeywell.com:  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the product  
could result in personal injury.  
Product line guide  
Product range guide  
Failure to comply with these instructions could result in  
death or serious injury.  
Application note: Flight deck toggle switches  
Application note: Sensors and switches in oil rig applications  
m WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
Warranty/Remedy  
Honeywell warrants goods of its manufacture as being free  
of defective materials and faulty workmanship. Honeywell’s  
standard product warranty applies unless agreed to otherwise by  
Honeywell in writing; please refer to your order acknowledgement  
or consult your local sales office for specific warranty details. If  
warranted goods are returned to Honeywell during the period of  
coverage, Honeywell will repair or replace, at its option, without  
charge those items it finds defective. The foregoing is buyer’s  
sole remedy and is in lieu of all other warranties, expressed  
or implied, including those of merchantability and fitness for  
a particular purpose. In no event shall Honeywell be liable for  
consequential, special, or indirect damages.  
Find out more  
Honeywell serves its customers  
through a worldwide network  
of sales offices, representatives  
and distributors. For application  
assistance, current specifica-  
tions, pricing or name of the  
nearest Authorized Distributor,  
contact your local sales office.  
To learn more about Honeywell’s  
sensing and switching products,  
call +1-815-235-6847 or  
While we provide application assistance personally, through our  
literature and the Honeywell web site, it is up to the customer to  
determine the suitability of the product in the application.  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this printing.  
However, we assume no responsibility for its use.  
1-800-537-6945,  
visit sensing.honeywell.com,  
or e-mail inquiries to  
info.sc@honeywell.com  
Honeywell Sensing and Productivity Solutions  
9680 Old Bailes Road  
005435-1-EN IL50 GLO  
April 2016  
Fort Mill, SC 29707  
© 2016 Honeywell International Inc. All rights reserved.  
honeywell.com  

相关型号:

64AT203-5

Toggle Switch, SPDT, Momentary, 1A, 28VDC, Wire Terminal, Lever Actuator, Panel Mount-threaded
HONEYWELL

64AT203-514

Toggle Switch, SPDT, Momentary, 1A, 28VDC, Wire Terminal, Lever Actuator, Panel Mount-threaded
HONEYWELL

64AT203-514B

Toggle Switch, 4PDT, Latched And Momentary, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded
HONEYWELL

64AT203-514G

Toggle Switch, 4PDT, Latched And Momentary, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded
HONEYWELL

64AT203-514L

Toggle Switch, 4PDT, Latched And Momentary, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded
HONEYWELL

64AT203-514N

Toggle Switch, 4PDT, Latched And Momentary, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded
HONEYWELL

64AT203-514P

Toggle Switch, 4PDT, Latched And Momentary, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded
HONEYWELL

64AT203-5F

Toggle Switch, 4PDT, Latched And Momentary, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded
HONEYWELL

64AT203-5K

Toggle Switch, 4PDT, Latched And Momentary, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded
HONEYWELL

64AT203-5M

Toggle Switch, 4PDT, Latched And Momentary, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded
HONEYWELL

64AT203-7

Toggle Switch, SPDT, Momentary, 1A, 28VDC, Wire Terminal, Lever Actuator, Panel Mount-threaded
HONEYWELL

64AT203-7N

Toggle Switch, 4PDT, Momentary, 1A, 28VDC, Wire Terminal, Locking Type Actuator, Panel Mount-threaded
HONEYWELL