ASDX005D44D [HONEYWELL]

Peizoresistive Sensor, Differential, 0Psi Min, 5Psi Max, 2%, 0.50-4.50V, Rectangular, Through Hole Mount, DIP-8;
ASDX005D44D
型号: ASDX005D44D
厂家: Honeywell    Honeywell
描述:

Peizoresistive Sensor, Differential, 0Psi Min, 5Psi Max, 2%, 0.50-4.50V, Rectangular, Through Hole Mount, DIP-8

传感器 换能器
文件: 总4页 (文件大小:263K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Microstructure Pressure Sensors  
0 psi to 1 psi through 0 psi to 100 psi  
ASDX Series  
FEATURES  
ASIC enhanced output  
Wide compensated  
temperature range 0 °C to  
85 °C [32 °F to 185 °F]  
Available in absolute,  
differential and gage types  
Pressure ranges from  
0 psi to 1 psi through  
0 psi to 100 psi  
Accuracy 2 % max. Volts  
Full Scale  
Quantization step of 3 mV  
Response time 8 ms  
TYPICAL APPLICATIONS  
Flow calibrators  
The ASDX series is an amplified version of Honeywell’s proven performer  
and industry leading SDX series sensor. The amplified ASDX sensor’s  
footprint is slightly larger than the SDX but it offers a high level output (4.0  
Vdc span) on a very cost-effective basis. This series is fully calibrated and  
temperature compensated with on-board Application Specific Integrated  
Circuitry (ASIC). They are intended for use with non-corrosive, non-ionic  
working fluids; such as air and dry gases.  
Ventilation and air flow  
monitors  
Gas flow instrumentation  
Dialysis equipment  
Sleep apnea monitoring  
and therapy equipment  
Barometry  
HVAC controls  
Pneumatic controls  
Sensors are available to measure absolute, differential, and gage pressures.  
The absolute devices have an internal vacuum reference and an output  
voltage proportional to absolute pressure. Differential devices allow  
application of pressure to either side of the sensing diaphragm and can be  
used for gauge or differential measurements.  
All ASDX devices are accurate to within 2.0 % full scale, designed for  
operation from a single 5.0 Vdc supply and are manufactured in accordance  
with ISO 9001 standards.  
WARNING  
PERSONAL INJURY  
DO NOT USE these  
products as safety or  
emergency stop devices or  
in any other application  
where failure of the product  
could result in personal  
injury.  
Failure to comply with  
these instructions could  
result in death or serious  
injury.  
WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet is for reference only. Do  
not use this document as a product installation guide.  
Complete installation, operation, and maintenance information is provided  
in the instructions supplied with each product.  
Failure to comply with these instructions could result in death or  
serious injury.  
Sensing and Control  
Microstructure Pressure Sensors  
0 psi to 1 psi through 0 psi to 100 psi  
ASDX Series  
BLOCK DIAGRAM  
ELECTRICAL CONNECTIONS(2) PIN OUT  
ASDXxxxD4*  
ASDXxxxG2*  
ASDXxxxA2*  
* N/C means no connection, connecting to ground will damage to sensor.  
SPECIFICATIONS (Maximum Ratings)  
Supply Voltage (Vs)*  
Maximum Supply Voltage*  
Consumption Current  
Output Current - Sink  
Output Current - Source  
Lead Temperature  
4.75 Vdc to 5.25 Vdc  
6.50 Vdc (max.)  
6 mA (typ.)  
2 mA (max.)  
2 mA (max.)  
2 Sec to 4 Sec @ 250 °C [482 °F]  
*Note: The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin can cause  
electrical failure. Application of supply voltage above the maximum can cause electrical failure.  
ENVIRONMENTAL SPECIFICATIONS (ALL DEVICES)  
Temperature Ranges:  
Compensated:  
Operating:  
Storage:  
0 °C to 85 °C [32 °F to 185 °F]  
-20 °C to 105 °C [-4 °F to 221 °F]  
-40 °C to 125 °C [-40 °F to 257 °F]  
10 g at 20 Hz to 2000 Hz  
50 g for 11 ms  
Vibration:  
Shock:  
Life:  
1 million cycles minimum  
PRESSURE RANGE SPECIFICATIONS  
Part No.  
Pressure Range  
0 psi to 1 psi  
0 psi to 5 psi  
0 psi to 15 psi  
0 psi to 30 psi  
0 psi to 100 psi  
Burst Pressure (3)  
5 psi  
Sensitivity  
4.00 V/psi  
0.80 V/psi  
0.267 V/psi  
0.133 V/psi  
0.040 V/psi  
ASDX001  
ASDX005  
ASDX015  
ASDX030  
ASDX100  
20 psi  
30 psi  
60 psi  
150 psi  
2 Honeywell Sensing and Control  
Microstructure Pressure Sensors  
0 psi to 1 psi through 0 psi to 100 psi  
ASDX Series  
PERFORMANCE SPECIFICATIONS(4)  
Characteristic  
Symbol  
Voff  
Min.  
Typ.  
0.500  
4.00  
4.500  
Max.  
Units  
Vdc  
Vdc  
Vdc  
% Vfs  
ms  
Zero Pressure Offset  
Full Scale Span(5)  
Output at FS Pressure  
Accuracy(6)  
Response Time(7)  
Quantization Step(8)  
0.420  
0.580  
Vfss  
Vfso  
4.420  
4.580  
2.0  
8
3
mV  
SPECIFICATION NOTES  
Note 1: Capacitor 220 nF required between +Vs and GND pin.  
Note 2: Pins 4, 5, 6, 7 and 8 are internal device connections and should not be connected to external circuitry or ground.  
Note 3: If maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may  
fracture.  
Note 4: Reference Conditions (unless otherwise noted): Supply voltage, VS=5.0 0.01 Vdc; TA=25 °C [77 °F]. Output is ratiometric within  
the supply voltage range (Vs).  
Note 5: Span is the algebraic difference between the output voltage at the specified pressure and the output at zero pressure. Span is  
ratiometric to the supply voltage.  
Note 6: Accuracy is the combined errors from offset and span calibration, linearity, pressure hysteresis, and temperature effects.  
Linearity is the measured deviation based on a straight line.  
Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing  
pressure.  
Calibration errors include the deviation of offset and full scale from nominal values.  
Note 7: Response time for a 0 psi to full-scale pressure step change, 10 % to 90 % rise time.  
Note 8: The smallest change in the output voltage, given any change in pressure.  
PRESSURE TRANSDUCER PERFORMANCE CHARACTERISTICS  
Error Band Multiplier Over -20 °C to 105 °C [-4 °F to 221 °F]  
ORDERING INFORMATION - PART NUMBER DESCRIPTION  
ASDX XXX  
XX  
4X  
Sensor Series  
Device Output  
4R = 0.5 Vdc to 4.5 Vdc  
4D = 2.5 ±2.0 Vdc*  
4H = 0.25 Vdc to 4.25 Vdc*  
4M = 0.2 Vdc to 4.7 Vdc*  
For example:  
Pressure Ranges  
001 = 0 psi to 1 psi  
005 = 0 psi to 5 psi  
Part #ASDX015A24R=ASDX  
device 15 psi absolute,  
A2 Package, 0.5 Vdc to 4.5 Vdc  
Output  
D, G  
D, G  
015 = 0 psi to 15 psi D, G, A  
030 = 0 psi to 30 psi D, G, A  
100 = 0 psi to 100 psi D, G, A  
Package Style and Type  
A2 = DIP Package Absolute  
D4 = DIP Package Differential  
D2, G2 = DIP Package, Gage  
* Contact Honeywell for additional information.  
Honeywell Sensing and Control 3  
Microstructure Pressure Sensors  
ASDX Series  
0 to 1 psi through 0 to 100 psi  
TO ORDER, USE THE FOLLOWING PART NUMBER(S)  
Pressure Range  
Absolute  
Gauge  
Differential  
Bidirectional  
0 psi to 1 psi  
0 psi to 5 psi  
0 psi to 15 psi  
0 psi to 30 psi  
0 psi to 100 psi  
ASDX001G24R  
ASDX005G24R  
ASDX015G24R  
ASDX030G24R  
ASDX100G24R  
ASDX001D44R  
ASDX005D44R  
ASDX015D44R  
ASDX030D44R  
ASDX100D44R  
ASDX001D44D  
ASDX005D44D  
ASDX015D44D  
ASDX030D44D  
ASDX100D44D  
ASDX015A24R  
ASDX030A24R  
ASDX100A24R  
DIMENSIONAL DRAWINGS - For Reference Only mm [in]  
D4 Package  
G2 Package  
A2 Package  
WARRANTY/REMEDY  
While we provide application assistance personally, through our  
literature and the Honeywell web site, it is up to the customer to  
determine the suitability of the product in the application.  
For application assistance, current specifications, or name of the  
nearest Authorized Distributor, contact a nearby sales office. Or call:  
1-800-537-6945 USA  
1-800-737-3360 Canada  
1-815-235-6847 International  
FAX  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Contact your local sales  
office for warranty information. If warranted goods are returned to  
Honeywell during the period of coverage, Honeywell will repair or  
replace without charge those items it finds defective. The foregoing  
is Buyer’s sole remedy and is in lieu of all other warranties,  
expressed or implied, including those of merchantability and  
fitness for a particular purpose.  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this printing.  
However, we assume no responsibility for its use.  
1-815-235-6545 USA  
INTERNET  
www.honeywell.com/sensing  
info.sc@honeywell.com  
Sensing and Control  
www.honeywell.com/sensing  
Honeywell  
11 West Spring Street  
Freeport, Illinois 61032  
008090-3-EN IL50 GLO 1105 Printed in USA  
Copyright 2005 Honeywell International Inc. All Rights Reserved.  

相关型号:

ASDX005D44D-A

Signal conditioned high precision pressure transducers
SENSORTECHNIC

ASDX005D44H

0 TO 1 PSI THROUGH 0 TO 100 PSI PRESSURE TRANSDUCERS SenSym ICT
ETC

ASDX005D44M

0 TO 1 PSI THROUGH 0 TO 100 PSI PRESSURE TRANSDUCERS SenSym ICT
ETC

ASDX005D44R

Signal conditioned pressure transducers
SENSORTECHNIC

ASDX005D44R-A

Signal conditioned high precision pressure transducers
SENSORTECHNIC

ASDX005G24D

0 TO 1 PSI THROUGH 0 TO 100 PSI PRESSURE TRANSDUCERS SenSym ICT
ETC

ASDX005G24H

0 TO 1 PSI THROUGH 0 TO 100 PSI PRESSURE TRANSDUCERS SenSym ICT
ETC

ASDX005G24M

0 TO 1 PSI THROUGH 0 TO 100 PSI PRESSURE TRANSDUCERS SenSym ICT
ETC

ASDX005G24R

Signal conditioned pressure transducers
SENSORTECHNIC

ASDX005G24R

Peizoresistive Sensor, Gage, 0Psi Min, 5Psi Max, 2%, 0.50-4.50V, Rectangular, Through Hole Mount, DIP-8
HONEYWELL

ASDX005G24R-A

Signal conditioned high precision pressure transducers
SENSORTECHNIC

ASDX015A24D

0 TO 1 PSI THROUGH 0 TO 100 PSI PRESSURE TRANSDUCERS SenSym ICT
ETC