CPC60G [HONEYWELL]

Peizoresistive Sensor, Gage, 60Psi Max, 0-90mV, Square, Through Hole Mount;
CPC60G
型号: CPC60G
厂家: Honeywell    Honeywell
描述:

Peizoresistive Sensor, Gage, 60Psi Max, 0-90mV, Square, Through Hole Mount

传感器 换能器
文件: 总4页 (文件大小:478K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Silicon Pressure Sensors  
Uncompensated/Compensated  
and Compensated Calibrated  
CPC, CPCL,  
CPX, CPXL Series  
FEATURES  
Low Cost, Small Size  
Temperature Compensated  
Zero and Span Calibrated  
Millivolt Output  
Differential, Gage and  
Absolute Pressure  
Constant Voltage  
Excitation  
High Impedance - Low  
Current  
TYPICAL APPLICATIONS  
Medical Applications  
Applications Requiring  
Small Size  
Applications Requiring  
Vacuum and Positive  
Pressure Reference, or  
GENERAL DESCRIPTION  
Both  
The CPX/CPXL and the CPC/CPCL Series sensors integrate silicon  
micromachined sensing technology, temperature compensation, and  
calibration in a complete family of low cost packages. This series offers the  
most cost-effective solution for design requirements.  
These piezoresistive pressure sensors use micromachined silicon chips  
mounted on a ceramic and protected with a plastic cap. Several tube  
arrangements with nylon housings are available for various pressure  
applications.  
On devices of 5 psi and above, the top side of the chip is protected against  
humidity by a Silgel coating. While the sensors are designed for use with  
non-corrosive, nonionic pressure media, they accommodate many gases  
that are used in medical applications.  
The CPC Series is designed for the lowest cost and smallest profile. The  
standard packages have only a plastic cap for OEM applications. The CPC  
axial port option accommodates pressure measurements in tube  
applications.  
WARNING  
PERSONAL INJURY  
DO NOT USE these  
products as safety or  
emergency stop devices or  
in any other application  
where failure of the product  
could result in personal  
injury.  
Failure to comply with  
these instructions could  
result in death or serious  
injury.  
WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet is for reference only.  
Do not use this document as a product installation guide.  
Complete installation, operation, and maintenance information is  
provided in the instructions supplied with each product.  
Failure to comply with these instructions could result in death or  
serious injury.  
Sensing and Control  
Silicon Pressure Sensors  
CPC, CPCL  
CPX, CPXL Series  
Uncompensated/Compensated  
and Compensated Calibrated  
ELECTRICAL SPECIFICATIONS  
CPC and CPCL @ 12 Vdc,  
CPX and CPXL CPCL @ 5 Vdc,  
25 °C [77 °F]  
25 °C [77 °F]  
Min.  
3.0  
Typ.  
12.0  
0
Max.  
16.0  
1.0  
Min.  
3.0  
Typ.  
5.0  
0
Max.  
12.0  
50  
Units  
Vdc  
Excitation Voltage  
Null  
-1.0  
-50  
mV  
Offset Temperature Shift  
0 °C to 70 °C [32 °F to 158 °F]**  
Full Scale Temperature Shift 0  
°C to 70 °C [32 °F to 158 °F]2  
Linearity, Hysteresis Error3  
Input Resistance  
--  
--  
--  
--  
±1.0  
±2  
--  
--  
±0.5  
mV  
-2050  
PPM/°C  
0.25  
--  
% Span  
--  
0.25  
--  
1.0  
1.0  
% Span  
k  
kΩ  
°C [°F]  
5.0  
--  
--  
5.0  
--  
--  
--  
--  
Output Resistance  
--  
-25 [-13]  
-40 [-40]  
--  
3.0  
--  
3.0  
--  
Operating Temperature  
Storage Temperature  
Common Mode Pressure  
Weight  
85 [185]  
-25 [-13]  
85 [185]  
--  
125 [257] -40 [-40]  
--  
125 [257] °C [°F]  
--  
50  
--  
--  
--  
--  
50  
psi  
--  
2
2
--  
gram  
Note 1: Pressure specs obtained with pressure applied to the front of the sensor.  
Note 2: Shift is relative to 25 °C [77 °F]  
Note 3: Measured at ½ full scale rated pressure using BFSL  
ABSOLUTE OUTPUT  
CPC @ 12 Vdc,  
25 °C [77 °F]  
Output Full Scale Span, (mV)  
CPX @ 12 Vdc,  
25 °C [77 °F]  
Output Full Scale Span, (mV)  
Overpressure  
(Psi)  
FS Pressure  
Min.  
57  
Typ.  
60  
Max.  
63  
Min.  
112  
168  
168  
189  
210  
--  
Typ.  
168.5  
253  
253  
263.5  
295  
--  
Max.  
225  
338  
338  
338  
380  
--  
Max.  
5 psi  
15 psi  
15 psi  
30 psi  
60 psi  
100 psi  
150 psi  
85  
90  
95  
45 psi  
85  
90  
95  
90 psi  
85  
90  
95  
180 psi  
250 psi  
250 psi  
95  
100  
90  
105  
95  
85  
GAGE AND DIFFERENTIAL1 OUTPUT  
CPC and CPCL @ 12 Vdc,  
25 °C [77 °F]  
CPX and CPXL @ 12 Vdc,  
25 °C [77 °F]  
Overpressure  
FS Pressure  
Output Full Scale Span, (mV)  
Output Full Scale Span, (mV)  
(Psi)  
Max.  
3
Min.  
23  
19  
17  
57  
85  
85  
85  
95  
85  
Typ.  
25  
Max.  
27  
Min.  
50  
Typ.  
68  
Max.  
86  
4 in H2O  
10 in H2O  
1 psi  
20  
21  
45  
78.5  
75  
112  
110  
225  
338  
338  
338  
380  
338  
3
18  
19  
40  
3
5 psi  
60  
63  
112  
168  
168  
189  
210  
187  
168.5  
253  
15  
15 psi  
90  
95  
45  
30 psi  
90  
95  
253  
90  
60 psi  
90  
95  
263.5  
295  
180  
250  
250  
100 psi  
150 psi  
100  
90  
105  
95  
262.5  
Note 1: Differential common mode pressure should not exceed 50 psi  
2 Honeywell Sensing and Control  
Silicon Pressure Sensors  
CPC, CPCL  
CPX, CPXL Series  
Uncompensated/Compensated  
and Compensated Calibrated  
PHYSICAL DIMENSIONS for reference only mm [In]  
Non-ported Package  
AF and GF Package  
DF Package  
MEDIA COMPATIBILITY:  
Clean, dry gases only  
EQUIVALENT CIRCUIT  
Pinout  
P1 Port:  
Media must be compatible with epoxy based  
1. - V Excitation  
2. + Output Signal  
3. +V Excitation  
4. - Output Signal  
adhesive.  
P2 Port:  
Media must be compatible with nylon housing,  
epoxy adhesive and silicon.  
Honeywell Sensing and Control 3  
Silicon Pressure Sensors  
CPC, CPCL  
CPX, CPXL Series  
Uncompensated/Compensated  
and Compensated Calibrated  
CPC/CPCL/CPX/CPXL SERIES ORDER GUIDE  
WARRANTY/REMEDY  
Honeywell warrants goods of its manufacture as  
being free of defective materials and faulty  
workmanship. Contact your local sales office for  
warranty information. If warranted goods are  
returned to Honeywell during the period of coverage,  
Honeywell will repair or replace without charge those  
items it finds defective. The foregoing is Buyer’s  
sole remedy and is in lieu of all other warranties,  
expressed or implied, including those of  
merchantability and fitness for a particular  
purpose.  
While we provide application assistance personally,  
through our literature and the Honeywell web site, it  
is up to the customer to determine the suitability of  
the product in the application.  
For application assistance, current specifications, or  
name of the nearest Authorized Distributor, contact a  
nearby sales office. Or call:  
1-800-537-6945 USA/Canada  
1-815-235-6847 International  
FAX  
1-815-235-6545 USA  
Specifications may change without notice. The  
information we supply is believed to be accurate and  
reliable as of this printing. However, we assume no  
responsibility for its use.  
INTERNET  
www.honeywell.com/sensing  
info.sc@honeywell.com  
Sensing and Control  
www.honeywell.com/sensing  
Honeywell  
11 West Spring Street  
Freeport, Illinois 61032  
008054-2-EN IL50 GLO 1004 Printed in USA  
Copyright 2004 Honeywell International Inc. All Rights Reserved.  

相关型号:

CPC60GF

Peizoresistive Sensor, Gage, 60Psi Max, 0-90mV, Square, Through Hole Mount
HONEYWELL

CPC60GFC

Peizoresistive Sensor, Gage, 0Psi Min, 60Psi Max, 0-90mV, Square, Through Hole Mount
HONEYWELL

CPC60GFH

Peizoresistive Sensor, Gage, 0Psi Min, 60Psi Max, 0-90mV, Square, Through Hole Mount
HONEYWELL

CPC60GH

Peizoresistive Sensor, Vacuum Gage, -60Psi Min, 60Psi Max, Rectangular, Through Hole Mount
HONEYWELL

CPC60UT1

Triple Output Switchers
XPPOWER

CPC60UT2

Triple Output Switchers
XPPOWER

CPC6100

Support Circuit, PQFP48, TQFP-48
IXYS

CPC6826

High Voltage EL Lamp Driver
CLARE

CPC6826U

High Voltage EL Lamp Driver
CLARE

CPC7220

Low Charge Injection 8-Channel High Voltage Analog Switch
CLARE

CPC7220K

Low Charge Injection 8-Channel High Voltage Analog Switch
CLARE

CPC7220K

Low Charge Injection, 8-Channel High Voltage Analog Switch
IXYS