CSLA2DJI [HONEYWELL]
Analog Circuit, 1 Func, PACKAGE-3;型号: | CSLA2DJI |
厂家: | Honeywell |
描述: | Analog Circuit, 1 Func, PACKAGE-3 |
文件: | 总2页 (文件大小:266K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Solid State Sensors
CS Series
Linear Current Sensors
FEATURES
LINEAR CURRENT SENSORS
ɀ
ɀ
ɀ
ɀ
ɀ
ɀ
ɀ
Linear output
MICRO SWITCH CS series linear current
sensors incorporate our 91SS12-2 and
SS94A1linear output Hall effect transduc-
AC or DC current sensing
Through-hole design
TM
Fast response time
er (LOHET ). The sensing element is as-
Output voltage isolation from input
Minimum energy dissipation
Maximum current limited only by
conductor size
Adjustable performance and built-in
temperature compensation assures
reliable operation
sembled in a printed circuit board mount-
able housing. This housing is available in
four configuration as shown in mounting
dimension figures 1, 1a, 2 and 2a. Normal
mounting is with 0.375 inch long 4-40
screw and square nut (not provided) in-
serted in the housing or a 6-20 self-tap-
ping screw. The combination of the sen-
sor, flux collector, and housing compris-
es the holder assembly. These sensors
are ratiometric.
ɀ
ɀ
ɀ
Accurate, low cost sensing
Operating temperature range –25 to
85
°C
ɀ
Housing: PET polyester
ORDER GUIDE — BOTTOM MOUNT WITH 9SS SENSOR, SOURCE OUTPUT
Sensed
Sensitivity
mVȿN*
Mtg.
Dim.
Fig.
Supply
Volt.
Supply
Current
Current
(Amps
Offset
Offset
Shift
Response
Time
At 12 VDC
Catalog
Listing
Volt.
(Volts±10%)
(Volts DC) (mA Max.) Peak)
Nominal
± TOL
5.8
(%/°C)
(µ Sec.)
CSLA1CD
CSLA1CE
CSLA1DE
CSLA1CF
CSLA1DG
CSLA1CH
CSLA1DJ
CSLA1EJ
CSLA1DK
CSLA1EK
CSLA1EL
1
8 to 16
8 to 16
8 to 16
8 to 16
8 to 16
8 to 16
8 to 16
8 to 16
8 to 16
8 to 16
8 to 16
19
19
19
19
19
19
19
19
19
19
19
57
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
49.6
39.4
39.1
29.7
24.6
19.6
13.2
13.2
9.1
±.05
±.05
±.05
±.05
±.05
±.05
±.05
±.05
±.05
±.05
±.05
3
3
3
3
3
3
3
3
3
3
3
1
75
4.4
2
75
4.8
1
100
120
150
225
225
325
325
625
2.7
2
2.1
1
1.8
2
1.2
1a
2
1.5
1.7
1a
1a
9.4
1.3
5.6
1.3
BOTTOM MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT
Sensed
Sensitivity
mVȿN*
Mtg.
Dim.
Fig.
Supply
Volt.
Supply
Current
Current
(Amps
Offset
Offset
Shift
Response
Time
At 8 VDC
Catalog
Listing
Volt.
(Volts±2%)
(Volts DC) (mA Max.) Peak)
Nominal
32.7
26.1
25.6
19.6
16.2
8.7
± TOL
3.0
2.1
2.2
1.3
1.1
0.6
1.1
0.7
0.5
0.4
0.3
0.2
(%/°C)
(µ Sec.)
CSLA2CD
CSLA2CE
CSLA2DE
CSLA2CF
CSLA2DG
CSLA2DJ
CSLA2DH
CSLA2EJ
CSLA2DK
CSLA2EL
CSLA2EM
CSLA2EN
1
6 to 12
6 to 12
6 to 12
6 to 12
6 to 12
6 to 12
6 to 12
6 to 12
6 to 12
6 to 12
6 to 12
6 to 12
20
20
20
20
20
20
20
20
20
20
20
20
72
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
Vcc/2
±.02
3
3
3
3
3
3
3
3
3
3
3
3
1
92
±.02
2
92
±.02
1
125
150
225
235
310
400
550
765
950
±.02
2
±.02
2
±.020
±.0125
±.0125
±.0125
±.0125
±.007
±.007
2
9.8
1a
2
7.6
5.8
1a
1a
1a
4.3
3.1
2.3
NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block
out the effect of the temperature variation of the offset voltage which increases the accuracy of the device.
* N = number of turns
PDFINFO
p a g e - 0 5 8
58
Honeywell Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada
Solid State Sensors
CS Series
Linear Current Sensors
SIDE MOUNT WITH 9SS SENSOR, SOURCE OUTPUT
Sensitivity
Sensed
Offset
mVȿN*
Mtg.
Dim.
Fig.
Supply
Volt.
Supply
Current
Current
(Amps
Offset
Response
Time
(µ Sec.)
At 12 VDC
Catalog
Listing
Volt.
Shift
(Volts DC) (mA Max.) Peak)
(Volts±10%)
Nominal
± TOL
5.8
(%/°C)
CSLA1GD
CSLA1GE
CSLA1GF
2a
2a
2a
8 to 16
8 to 16
8 to 16
19
19
19
57
Vcc/2
Vcc/2
Vcc/2
49.6
39.4
29.7
±.05
±.05
±.05
3
3
3
75
4.4
100
2.7
SIDE MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT
Sensed
Sensitivity
mVȿN*
Mtg.
Dim.
Fig.
Supply
Volt.
Supply
Current
Current
(Amps
Offset
Offset
Shift
Response
Time
At 8 VDC
Catalog
Listing
Volt.
(Volts DC) (mA Max.) Peak)
(Volts±2%)
Nominal
32.7
± TOL
3.0
(%/°C)
(µ Sec.)
CSLA2GD
CSLA2GE
CSLA2GF
CSLA2GG
2a
2a
2a
2a
6 to 12
6 to 12
6 to 12
6 to 12
20
20
20
20
72
Vcc/2
Vcc/2
Vcc/2
Vcc/2
±.02
±.02
±.02
±.02
8
8
8
8
92
26.1
2.1
125
150
19.6
1.3
12.7
0.6
NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block
out the effect of the temperature variation of the offset voltage which increases the accuracy of the device.
*N = number of turns.
MOUNTING DIMENSIONS (for reference only)
Figure 1
Figure 2
PDFINFO
p a g e - 0 5 9
Figure 1a
Figure 2a
* Application consideration: The out-
put is clamped at the high end. Clamp-
ing voltage may be as low as 9VDC.
The output will not exceed the clamp-
ing voltage regardless of field strength
or supply voltage.
Honeywell Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada