HAFBSD200CAX5 [HONEYWELL]

HONEYWELL ZEPHYR DIGITAL AIRFLOW SENSORS: HAF SERIES-HIGH ACCURACY; HONEYWELL ZEPHYR数字气流传感器: HAF系列 - 高精度
HAFBSD200CAX5
型号: HAFBSD200CAX5
厂家: Honeywell    Honeywell
描述:

HONEYWELL ZEPHYR DIGITAL AIRFLOW SENSORS: HAF SERIES-HIGH ACCURACY
HONEYWELL ZEPHYR数字气流传感器: HAF系列 - 高精度

传感器
文件: 总6页 (文件大小:555K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DESCRIPTION  
These sensors operate on the heat transfer principle to  
measure mass airflow. They consist of a microbridge  
Microelectronic and Microelectromechanical System (MEMS)  
with temperature-sensitive resistors deposited with thin films of  
platinum and silicon nitride. The MEMS sensing die is located  
in a precise and calculated airflow channel to provide  
repeatable flow response.  
Honeywell ZephyrDigital Airflow Sensors: HAF Series-High  
Accuracy, provide a digital interface for reading airflow over the  
specified full scale flow span and temperature range. Their  
thermally isolated heater and temperature sensing elements  
help these sensors provide a fast response to air or gas flow.  
Zephyr sensors are designed to measure mass flow of air and  
other non-corrosive gases. They are available in standard flow  
ranges and are fully calibrated and temperature compensated  
with an on-board Application Specific Integrated Circuit (ASIC).  
Zephyr sensors provide customers with enhanced reliability,  
digital accuracy, repeatable measurements and the ability to  
customize sensor options to meet many specific application  
needs. The combination of rugged housings with a stable  
substrate makes these products extremely robust. They are  
designed and manufactured according to ISO 9001 standards.  
The HAF Series is compensated over the temperature range of  
0 C to 50 C [32 F to 122 F] and operates across a  
temperature range of -20 C to 70 C [-4 F to 158 F]. The  
state-of-the-art ASIC-based compensation provides digital (I2C)  
outputs with a response time of 1 ms.  
FEATURES AND BENEFITS (= competitive differentiator)  
High ±2.5% accuracy allows for very precise airflow  
measurement, often ideal for demanding applications with  
high accuracy requirements  
Full calibration and temperature compensation typically allow  
customer to remove additional components associated with  
signal conditioning from the PCB, reducing PCB size as well  
as costs often associated with those components (e.g.,  
acquisition, inventory, assembly)  
High 12-bit resolution increases ability to sense small airflow  
changes, allowing customers to more precisely control their  
application  
Low 3.3 Vdc operating voltage option and low power  
consumption allow for use in battery-driven and other  
portable applications  
ASIC-based I2C digital output compatibility eases integration  
to microprocessors or microcontrollers, reducing PCB  
complexity and component count  
Customizable for specific end-user needs  
Bidirectional flow sensing capability eliminates the need for  
two airflow sensors, helping to reduce production costs and  
implementation time  
Insensitivity to mounting orientation allows customer to  
position sensor in most optimal point in the system,  
eliminating concern for positional effects  
High sensitivity at very low flows allows a customer’s  
application to detect presence or absence of airflow  
High stability reduces errors due to thermal effects and null  
shift to provide accurate readings over time, often eliminating  
need for system calibration after PCB mount and periodically  
over time  
Insensitivity to altitude eliminates customer-implemented  
altitude adjustments in the system, easing integration and  
reducing production costs by not having to purchase  
additional sensors for altitude adjustments  
Small size occupies less space on PCB, allowing easier fit  
and potentially reducing production costs; PCB size may  
also be reduced for easier fit into space-constrained  
applications  
Low pressure drop typically improves patient comfort in  
medical applications, and reduces noise and system wear on  
other components such as motors and pumps  
Linear output provides more intuitive sensor signal than the  
raw output of basic airflow sensors, which can help reduce  
production costs, design, and implementation time  
Fast response time allows a customer's application to  
respond quickly to airflow change, important in critical  
medical (i.e., anesthesia) and industrial (i.e., fume hood)  
applications  
RoHS-compliant materials meet Directive 2002/95/EC  
POTENTIAL APPLICATIONS  
Medical  
Industrial  
Air-to-fuel ratio  
Anesthesia delivery machines  
Analytical instrumentation (spectrometry, chromatography)  
Ventricular assist devices (heart pumps)  
Hospital diagnostics (spectrometry, gas chromatography)  
Nebulizers  
Fuel cells  
Gas leak detection  
Gas meters  
Oxygen concentrators  
HVAC filters  
Patient monitoring systems (respiratory monitoring)  
Sleep apnea machines  
VAV system on HVAC systems  
Meteorolgy  
Spirometers  
Ventilators  
Table 1: Absolute Maximum Ratings1  
Characteristic  
Supply voltage  
Parameter  
-0.3 Vdc to 6.0 Vdc  
-0.3 V to Vsupply  
CAUTION  
IMPROPER USE  
Voltage on output pin  
Storage temperature range  
Maximum flow change  
Maximum common mode pressure  
Maximum flow  
Do not use these products to sense liquid or  
fluid flow.  
Failure to comply with these instructions  
may result in product damage.  
-40 C to 125 C [-40 F to 257 F]  
5.0 SLPM/s  
25 psi at 25 C [77 F]  
10 SLPM  
Note 1: Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and  
mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the  
device necessarily operate at absolute maximum ratings.  
Table 2: Operating Characteristics  
Characteristic  
Supply voltage  
Supply current  
Power:  
Parameter  
3.3 Vdc 10%; 5.0 Vdc 10%  
16 mA max.  
Note  
3.3 Vdc  
23 mW typ.  
5.0 Vdc  
38 mW typ.  
Operating temperature range  
Compensated temperature range  
Accuracy:  
-20 C to 70 C [-4 F to 158 F]  
0 C to 50 C [32 F to 122 F]  
1
2, 4  
forward flow  
reverse flow  
±0.25% FSS or ±2.5% of reading, whichever is greater  
±0.25% FSS or ±9% of reading, whichever is greater  
Total error band:  
forward flow:  
3, 4  
±0.25% FSS or ±4.5% of reading, whichever is greater  
reverse flow:  
±0.25% FSS or ±9% of reading, whichever is greater  
Null accuracy  
Response time  
Resolution  
±0.02% FSS  
1 ms typ.  
12 bit min.  
4, 10  
5
Start up time  
17 ms  
30 ms  
gaseous nitrogen  
I2C, fast mode (400 kHz)  
6
7
8
9
Warm up time  
Calibration media  
Bus standards  
Null stability  
±0.01% FSS maximum deviation from null output after 1000 hours at 25 C  
Reverse polarity protection  
no  
Notes:  
1. Custom and extended compensated temperature ranges are possible. Contact Honeywell for details.  
2. Accuracy is the maximum deviation from the nominal digital output over the compensated flow range at a reference temperature of 25 C.  
Errors include offset, span, non-linearity, hysteresis and non-repeatability (see Figure 3 for the Accuracy Error Band vs Flow).  
3. Total error band includes all errors over the compensated flow range including all effects due to temperature over the compensated  
temperature range (see Figure 4 for the Total Error Band).  
4. Full Scale Span (FSS) is the algebraic difference between the digital output at the forward Full Scale (FS) flow and the digital output at the  
reverse FS flow. Forward flow is defined as flow from P1 to P2 as shown in Figure 4. The references to mass flow (SCCM) refer to gas flows at  
the standard conditions of 0 C and atmospheric pressure 760 (101.3 kPa).  
5. Response time: time to electrically respond to any mass flow change at the microbridge airflow transducer (response time of the transducer  
may be affected by the pneumatic interface).  
6. Start-up time: time to first valid reading of serial number proceeding streaming 14-bit flow measurements.  
7. Warm-up time: time to the first valid flow measurement after power is applied.  
8. Default calibration media is dry nitrogen gas. Please contact Honeywell for other calibration options.  
9. Refer to Honeywell Technical Note for I2C protocol information.  
10. Null accuracy is the maximum deviation in output at 0 SCCM from the ideal transfer function over the compensated temperature range. This  
includes offset errors, thermal airflow hysteresis and repeatability errors.  
2
www.honeywell.com/sensing  
Table 3. Environmental Characteristics  
Characteristic  
Humidity  
Parameter  
0% to 95% RH, non-condensing  
100 g, 11 ms  
Shock  
Vibration  
15 g at 20 Hz to 2000 Hz  
ESD  
Class 3B per MIL-STD 883G  
Radiated immunity  
Level 3 from (80 MHz to 1000 MHz) per spec IEC61000-4-3  
Table 4. Wetted Materials  
Characteristic  
Covers  
Parameter  
high temperature polymer  
PCB  
Substrate  
Adhesives  
epoxy  
Electronic components  
Compliance  
silicon, gold  
RoHS, WEEE  
Table 5. Recommended Mounting and Implementation  
Characteristic  
Parameter  
5-40  
0.68 N m [6 in-lb]  
CAUTION  
Mounting screw size  
Mounting screw torque  
Tubing for long port style  
LARGE PARTICULATE DAMAGE  
Use a 5-micron filter upstream of the sensor  
to keep media flow through the sensor free of  
condensing moisture and particulates. Large,  
high-velocity particles or conductive particles  
may damage the sensing element.  
Failure to comply with these instructions  
may result in product damage.  
70 durometer, size 0.125 inch inside  
diameter, 0.250 inch outside diameter silicone  
tubing  
O-ring for short port style  
O-ring for long port style  
Filter recommendation  
AS568A, Size 7, Silicone, Shore A 70  
AS568A, Size 10, Silicone, Shore A 70  
5-micron filter upstream of the sensor  
Figure 1. Nomenclature and Order Guide  
Example Catalog  
Listing  
HAFBLS0200C2AX5 =  
High accuracy airflow  
sensor, bidirectional  
forward flow optimized,  
long port style, snap  
mount housing, 200  
SCCM, digital I2C output  
with 0X29 address, 10%  
to 90% transfer function,  
5.0 Vdc supply voltage.  
Customer-specific  
Requirements  
Apart from the general  
configuration required,  
other customer-specific  
requirements are also  
possible. Please contact  
Honeywell.  
Note:  
1. The Long Port Port Style with the Snap Mount Housing Style is not a valid configuration.  
Honeywell Sensing and Control  
3
Figure 2. Nominal Digital Output  
Ideal Transfer Function  
Digital Output Code = 16383 * [0.5 + 0.4 * (Flow Applied/Full  
Scale Flow)]  
Flow Applied = Full Scale Flow * [(Digital Output Code/16383)  
- 0.5]/0.4  
Figure 3. Accuracy Error Band  
Figure 4. Total Error Band  
Figure 5. Long Port Style Flow vs Pressure  
Flow  
(SCCM)  
-200  
-150  
-100  
-50  
Pressure Drop  
(inches H2O)  
-0.019  
-0.013  
-0.007  
-0.001  
0
0.000  
50  
0.005  
100  
0.010  
150  
0.016  
200  
0.022  
Figure 6. Short Port Style Flow vs Pressure  
Flow  
(SCCM)  
-200  
-150  
-100  
-50  
Pressure Drop  
(inches H2O)  
-0.470  
-0.284  
-0.143  
-0.045  
0
0.000  
50  
0.048  
100  
0.139  
150  
0.287  
200  
0.452  
4
www.honeywell.com/sensing  
Figure 7. Wave Solder Profile  
300  
250  
200  
150  
100  
50  
Max. temp. = 243 °C  
Max. temp. = 205 °C  
Housing temp. (top of device)  
Pin temp. (bottom of device)  
0
0
20  
40  
60  
80  
100  
Time (s)  
Figure 8. Mounting Dimensions (For reference only: mm [in]). Additional port and housing styles available.  
Long Port Style, Fastener Mount  
Short Port Style, Snap Mount  
22,00  
[0.87]  
MODEL NUMBER  
LOT CODE  
DIA. 2,30  
[0.09]  
MODEL NUMBER  
LOT CODE  
TERMINAL SIDE  
7,20  
[0.28]  
3,0  
[0.12]  
2,00 TYP.  
[0.079]  
TERMINAL SIDE  
1,00  
[0.04]  
6,50  
[0.26]  
10,40  
[0.41]  
3,50  
[0.14]  
1
2 3  
4
26,00  
[1.02]  
7,20  
[0.28]  
2,00 TYP.  
[0.079]  
4,60  
10,3  
[0.40]  
3,3  
[0.13]  
1,00  
[0.04]  
[0.18]  
3,00  
[0.12]  
4,80  
[0.19]  
1
2 3 4  
10,00  
[0.39]  
1,80  
[0.071]  
10,3  
[0.40]  
12,8  
[0.50]  
2X DIA. 5,35  
[0.21]  
6,50  
[0.26]  
36,00  
[1.42]  
2,50  
[0.10]  
2X DIA. 2,2 [0.086] THRU  
HOLES FOR MOUNTING  
7,20  
[0.28]  
18,00  
[0.71]  
4X DIA. 0,812  
[0.032]  
19,90  
[0.78]  
22,0  
[0.866]  
3,80  
[0.150]  
0,65  
1
2
3
4
19,90  
[0.78]  
2X DIA. 3,40  
[0.026]  
7,20  
[0.28]  
[0.13]  
1
2
3
4
6,35  
[0.25]  
4,00  
2X 7,20  
[0.28]  
[0.157]  
4X DIA. 0,812  
[0.032]  
12,70  
[0.50]  
28,80  
[1.13]  
2X DIA. 3,40  
[0.134]  
6,35  
[0.25]  
2X 2,50  
[0.098]  
36,00  
[1.42]  
2X PORTS  
12,70  
[0.50]  
2X PORTS  
SENSOR FOOTPRINT  
VIEWED FROM TERMINAL SIDE  
28,80  
[1.13]  
26,00  
[1.024]  
AIRFLOW DIRECTION, PORT SIDE  
SENSOR FOOTPRINT  
VIEWED FROM TERMINAL SIDE  
AIRFLOW DIRECTION, PORT SIDE  
Pinout (digital function)  
1 = SCL  
2 = Vsupply  
3 = ground  
4 = SDA  
Honeywell Sensing and Control  
5
WARNING  
PERSONAL INJURY  
WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
Failure to comply with these instructions could result in  
death or serious injury.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
WARRANTY/REMEDY  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Honeywell s  
standard product warranty applies unless agreed to otherwise  
by Honeywell in writing; please refer to your order  
acknowledgement or consult your local sales office for specific  
warranty details. If warranted goods are returned to Honeywell  
during the period of coverage, Honeywell will repair or replace,  
at its option, without charge those items it finds defective. The  
foregoing is buyer s sole remedy and is in lieu of all other  
warranties, expressed or implied, including those of  
merchantability and fitness for a particular purpose. In no  
event shall Honeywell be liable for consequential, special,  
or indirect damages.  
SALES AND SERVICE  
Honeywell serves its customers through a worldwide network  
of sales offices, representatives and distributors. For  
application assistance, current specifications, pricing or name  
of the nearest Authorized Distributor, contact your local sales  
office or:  
E-mail: info.sc@honeywell.com  
Internet: www.honeywell.com/sensing  
Phone and Fax:  
While we provide application assistance personally, through  
our literature and the Honeywell web site, it is up to the  
customer to determine the suitability of the product in the  
application.  
Asia Pacific  
+65 6355-2828  
+65 6445-3033 Fax  
+44 (0) 1698 481481  
+44 (0) 1698 481676 Fax  
+1-305-805-8188  
Europe  
Latin America  
USA/Canada  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this  
printing. However, we assume no responsibility for its use.  
+1-305-883-8257 Fax  
+1-800-537-6945  
+1-815-235-6847  
+1-815-235-6545 Fax  
Sensing and Control  
Honeywell  
1985 Douglas Drive North  
008178-3-EN IL50 GLO Printed in USA  
May 2010  
2010 Honeywell International Inc. All rights reserved.  
Golden Valley, MN 55422  
www.honeywell.com  

相关型号:

HAFBSF0050C4ACAAX3

HAF Series–High Accuracy
HONEYWELL

HAFBSF0050C4ACAAX5

HAF Series–High Accuracy
HONEYWELL

HAFBSF0050C5ACAAX3

HAF Series–High Accuracy
HONEYWELL

HAFBSF0050C5ACAAX5

HAF Series–High Accuracy
HONEYWELL

HAFBSF0050C6ACAAX3

HAF Series–High Accuracy
HONEYWELL

HAFBSF0050C6ACAAX5

HAF Series–High Accuracy
HONEYWELL

HAFBSF0050C7ACAAX3

HAF Series–High Accuracy
HONEYWELL

HAFBSF0050C7ACAAX5

HAF Series–High Accuracy
HONEYWELL

HAFBSF0100C4ACAAX3

HAF Series–High Accuracy
HONEYWELL

HAFBSF0100C4ACAAX5

HAF Series–High Accuracy
HONEYWELL

HAFBSF0100C5ACAAX3

HAF Series–High Accuracy
HONEYWELL

HAFBSF0100C5ACAAX5

HAF Series–High Accuracy
HONEYWELL