HIH-4030 [HONEYWELL]

Humidity Sensors;
HIH-4030
型号: HIH-4030
厂家: Honeywell    Honeywell
描述:

Humidity Sensors

文件: 总8页 (文件大小:236K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HIH-4030/31 Series  
Humidity Sensors  
DESCRIPTION  
The HIH-4030/4031 Series delivers instrumentation-quality RH  
(Relative Humidity) sensing performance in a competitively  
priced, solderable SMD.  
Honeywell has expanded our HIH Series to include an SMD  
(Surface Mount Device) product line: the new HIH 4030/4031.  
The HIH 4030/4031 complements our existing line of non-SMD  
humidity sensors. SMD packaging on tape and reel allows for  
use in high volume, automated pick and place manufacturing,  
eliminating lead misalignment to printed circuit board through-  
hole.  
The HIH-4030 is a covered integrated circuit humidity sensor.  
The HIH-4031 is a covered, condensation-resistant, integrated  
circuit humidity sensor that is factory-fitted with a hydrophobic  
filter allowing it to be used in condensing environments  
including industrial, medical and commercial applications.  
The HIH-4030/4031 Series Humidity Sensors are designed  
specifically for high volume OEM (Original Equipment  
Manufacturer) users.  
The RH sensor uses a laser trimmed, thermoset polymer  
capacitive sensing element with on-chip integrated signal  
conditioning.  
Direct input to a controller or other device is made possible by  
this sensor’s near linear voltage output. With a typical current  
draw of only 200 μA, the HIH-4030/4031 Series is often ideally  
suited for low drain, battery operated systems.  
The sensing element's multilayer construction provides  
excellent resistance to most application hazards such as  
condensation, dust, dirt, oils and common environmental  
chemicals.  
Tight sensor interchangeability reduces or eliminates OEM  
production calibration costs. Individual sensor calibration data  
is available.  
Sample packs are available. See order guide.  
FEATURES  
POTENTIAL APPLICATIONS  
Tape and reel packaging allows for use in high volume pick  
and place manufacturing (1,000 units per tape and reel)  
Molded thermoset plastic housing  
Near linear voltage output vs %RH  
Laser trimmed interchangeability  
Low power design  
Refrigeration equipment  
HVAC (Heating, Ventilation and Air Conditioning)  
equipment  
Medical equipment  
Drying  
Metrology  
Enhanced accuracy  
Battery-powered systems  
OEM assemblies  
Fast response time  
Stable, low drift performance  
Chemically resistant  
HIH-4030/31 Series  
TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.)  
Parameter  
Minimum  
Typical  
Maximum  
Unit  
Specific  
Note  
Interchangeability (first order curve)  
0% RH to 59% RH  
60% RH to 100% RH  
Accuracy (best fit straight line)  
Hysterisis  
Repeatability  
Settling time  
Response time (1/e in slow moving air)  
Stability (at 50% RH in a year)  
Stability (at 50% RH in a year)  
Voltage supply  
-5  
-8  
-3.5  
5
8
+3.5  
% RH  
% RH  
% RH  
% RH  
% RH  
ms  
3
0.5  
1
70  
5
s
1.2  
0.5  
% RH  
% RH  
Vdc  
2
3
4
5.8  
500  
4
Current supply  
200  
μA  
Voltage output (1st order curve fit)  
Temperature compensation  
Output voltage temp. coefficient at 50% RH, 5 V  
Operating temperature  
Operating humidity (HIH-4030)  
Operating humidity (HIH-4031)  
Storage temperature  
VOUT=(VSUPPLY)(0.0062(sensor RH) + 0.16), typical at 25 ºC  
True RH = (Sensor RH)/(1.0546 – 0.00216T), T in ºC  
-40[-40]  
0
-4  
mV/ºC  
ºC[ºF]  
% RH  
% RH  
ºC[ºF]  
% RH  
5
5
See Figure 1.  
See Figure 1.  
See Figure 1.  
85[185]  
100  
100  
0
-50[-58]  
125[257]  
Storage humidity  
Specific Notes:  
See Figure 2.  
General Notes:  
1. Can only be achieved with the supplied slope and offset. For  
Sensor is ratiometric to supply voltage.  
Extended exposure to >90% RH causes a reversible  
shift of 3% RH.  
Sensor is light sensitive. For best performance, shield  
sensor from bright light.  
HIH-4030/31-003 catalog listings only.  
2. Includes testing outside of recommended operating zone.  
3. Includes testing for recommended operating zone only.  
4. Device is calibrated at 5 Vdc and 25 ºC.  
5. Non-condensing environment. When liquid water falls on the  
humidity sensor die, output goes to a low rail condition  
indicating no humidity.  
FACTORY CALIBRATION DATA  
HIH-4030/31 Sensors may be ordered with a calibration and  
data printout. See Table 2 and the order guide on the back  
page.  
TABLE 2. EXAMPLE DATA PRINTOUT  
Model  
Channel  
HIH-4030-003  
92  
Wafer  
MRP  
030996M  
337313  
Calculated values at 5 V  
V
at 0% RH  
0.958 V  
3.268 V  
VOOUUTT at 75.3% RH  
Linear output for 3.5% RH  
accuracy at 25 °C  
Zero offset  
Slope  
Sensor RH  
0.958 V  
30.680 mV/%RH  
(VOUT - zero offset)/slope  
(VOUT - 0.958)/0.0307  
Ratiometric response for  
0% RH to 100% RH  
VOUT  
VSUPPLY (0.1915 to 0.8130)  
2
www.honeywell.com/sensing  
Humidity Sensors  
FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment for HIH-4030 catalog listings only.)  
FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment for HIH-4030 catalog listings only.)  
100%  
90%  
80%  
70%  
60%  
50%  
40%  
30%  
20%  
10%  
0%  
-40  
-20  
0
20  
40  
60  
80  
120 140  
100  
Recommended storage zone  
Temperature ºC  
Honeywell Sensing and Control  
3
HIH-4030/31 Series  
FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.)  
4
3.5  
3
2.5  
2
Sensor Response  
Sensor Response  
Best Linear Fit  
1.5  
1
0.5  
0
20  
40  
60  
80  
100  
Relative Humidity (%RH)  
FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.)  
4.5  
4
3.5  
3
2.5  
2
0 C  
70 C  
1.5  
1
0.5  
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Relative Humidity (%)  
4
www.honeywell.com/sensing  
Humidity Sensors  
FIGURE 5. HIH-4030 MOUNTING DIMENSIONS (For reference only. mm/[in])  
Honeywell Sensing and Control  
5
HIH-4030/31 Series  
FIGURE 6. HIH-4031 MOUNTING DIMENSIONS (For reference only. mm/[in])  
FIGURE 7. HIH-4031 PCB LANDING PATTERN (For reference only. mm/[in])  
6
www.honeywell.com/sensing  
Humidity Sensors  
FIGURE 8. TAPE AND REEL DIMENSIONS (For reference only. mm/[in])  
3,99  
[0.157]  
3,91  
[0.154]  
1,75  
[0.069]  
DIA. 1,50  
[0.059]  
2,01  
[0.079]  
2,64  
[0.104]  
11,51  
[0.453]  
24,00  
[0.945]  
2,64  
[0.076]  
22,25  
[0.876]  
DIA. 1,50  
[0.059]  
8,00  
[0.315]  
0,343  
[0.0135]  
FIGURE 9. TYPICAL APPLICATION CIRCUIT  
ORDER GUIDE  
Catalog Listing  
HIH-4030-001  
HIH-4030-003  
HIH-4031-001  
HIH-4031-003  
Description  
Covered integrated circuit humidity sensor, SMD, 1000 units on tape and reel  
Covered integrated circuit humidity sensor, SMD, calibration and data printout, 1000 units on tape and reel  
Covered, filtered integrated circuit humidity sensor, SMD, 1000 units on tape and reel  
Covered, filtered integrated circuit humidity sensor, SMD, calibration and data printout, 1000 units on tape  
and reel  
HIH-4030-001S  
HIH-4030-003S  
Sample pack: covered integrated circuit humidity sensor, SMD, five units on tape  
Sample pack: covered integrated circuit humidity sensor, SMD, calibration and data printout, five units on  
tape  
HIH-4031-001S  
HIH-4031-003S  
Sample pack: covered, filtered integrated circuit humidity sensor, SMD, sample pack, five units on tape  
Sample pack: covered, filtered integrated circuit humidity sensor, SMD, calibration and data printout, five  
units on tape  
FURTHER HUMIDITY SENSOR INFORMATION  
See the following associated literature is available on the Web:  
Product installation instructions  
Application sheets:  
Humidity Sensor Performance Characteristics  
Humidity Sensor Theory and Behavior  
Humidity Sensor Moisture and Psychrometrics  
Thermoset Polymer-based Capacitive Sensors  
Honeywell Sensing and Control  
7
WARNING  
MISUSE OF DOCUMENTATION  
WARNING  
PERSONAL INJURY  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result  
in death or serious injury.  
Failure to comply with these instructions could result  
in death or serious injury.  
SALES AND SERVICE  
Honeywell serves its customers through a worldwide network  
of sales offices, representatives and distributors. For  
application assistance, current specifications, pricing or name  
of the nearest Authorized Distributor, contact your local sales  
office or:  
WARRANTY/REMEDY  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Honeywell’s  
standard product warranty applies unless agreed to otherwise  
by Honeywell in writing; please refer to your order  
acknowledgement or consult your local sales office for specific  
warranty details. If warranted goods are returned to Honeywell  
during the period of coverage, Honeywell will repair or replace,  
at its option, without charge those items it finds defective. The  
foregoing is buyer’s sole remedy and is in lieu of all other  
warranties, expressed or implied, including those of  
merchantability and fitness for a particular purpose. In no  
event shall Honeywell be liable for consequential, special,  
or indirect damages.  
E-mail: info.sc@honeywell.com  
Internet: www.honeywell.com/sensing  
Phone and Fax:  
Asia Pacific  
+65 6355-2828  
+65 6445-3033 Fax  
+44 (0) 1698 481481  
+44 (0) 1698 481676 Fax  
+1-305-805-8188  
+1-305-883-8257 Fax  
+1-800-537-6945  
Europe  
Latin America  
USA/Canada  
While we provide application assistance personally, through  
our literature and the Honeywell web site, it is up to the  
customer to determine the suitability of the product in the  
application.  
+1-815-235-6847  
+1-815-235-6545 Fax  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this  
printing. However, we assume no responsibility for its use.  
Sensing and Control  
Honeywell  
1985 Douglas Drive North  
009021-4-EN IL50 GLO Printed in USA  
March 2008  
© 2008 Honeywell International Inc. All rights reserved.  
Minneapolis, MN 55422  
www.honeywell.com/sensing  

相关型号:

HIH-4030-001

HIH-4030/31 Series Humidity Sensors
HONEYWELL

HIH-4030-001S

HIH-4030/31 Series Humidity Sensors
HONEYWELL

HIH-4030-003

HIH-4030/31 Series Humidity Sensors
HONEYWELL

HIH-4030-003S

HIH-4030/31 Series Humidity Sensors
HONEYWELL

HIH-4031

Humidity Sensors
HONEYWELL

HIH-4031-001

HIH-4030/31 Series Humidity Sensors
HONEYWELL

HIH-4031-001S

HIH-4030/31 Series Humidity Sensors
HONEYWELL

HIH-4031-003

HIH-4030/31 Series Humidity Sensors
HONEYWELL

HIH-4031-003S

HIH-4030/31 Series Humidity Sensors
HONEYWELL

HIH-4602-A

Humidity Sensors
HONEYWELL

HIH-4602-C

Humidity Sensors
HONEYWELL

HIH-4602-L

HIH-4602 Series monolithic IC humidity sensor in TO-5 can
HONEYWELL