KGZ-10 Series  
Oxygen Sensors  
DESCRIPTION  
A heat element produces the 700 C [1292 F]required for the  
ZrO to operate as an O pump. The time taken for the pump to  
achieve specific minimum and maximum pressures within this  
chamber is a measure of the partial oxygen pressure of the  
environment.  
The KGZ-10 is a high-accuracy, zirconia-based oxygen sensor.  
The ability of the sensor to operate without any reference gas  
makes it ideal for potential applications such as combustion  
control or aircraft oxygen generation systems.  
2
2
The sensor employs two ZrO discs with a small hermetically  
2
sealed chamber in between. One of the discs functions as a  
reversible oxygen pump, which is used to successively fill and  
empty the chamber. The second disc measures the ratio of the  
partial pressure difference and generates a corresponding  
sense voltage.  
The KGZ-10 has to be operated by an electronic measuring  
circuit that controls the sensor operation and signal processing.  
This circuit can either be incorporated into the customer s own  
electronics, or be purchased as a separate interface board  
from Honeywell.  
FEATURES  
POTENTIAL APPLICATIONS  
Boiler combustion controls  
Aircraft oxygen generation systems  
High-accuracy measurement  
Low power consumption  
No reference gas required  
Linear output signal  
No need for temperature stabilization  
Function testing and calibration in ambient air  
Long life  
KGZ-10 Series  
Table 1. Technical Specifications  
Characteristic  
Parameter  
45-64-85 mV  
40 uA  
Sensor voltage levels (recommended)  
Pump current (recommended)  
Heater supply,  
4.0 V (1.7 A)  
2.0 V  
Heater supply (stand by)  
Pump resistance at 700 C [1292 F]:  
dc  
1 kOhm, typ.  
1 kHz, 120 Ohm, typ.  
2 mbar to 3 bar  
700 C [1292 F]  
500 C [932 F], typ.  
1.05 ms/mbar  
<5 mbar  
ac  
Oxygen pressure range  
Operational temperature  
Stand by temperature  
Sensitivity  
Accuracy  
Response time  
<4 s  
Warm up time  
<100 s  
Warm up time (from stand by)  
Permissible gas temperature  
Gas flow rate  
<20 s  
-100 C/250 C [-148 F/482 F]  
0 m/s to 10 m/s  
5 g  
Repetitive permissible acceleration  
Incidental permissible acceleration  
30 g  
2
www.honeywell.com/sensing  
Oxygen Sensors  
Figure 1. KGZ-10 Dimensions (For reference only: mm/in.)  
Figure 2. KGZ-10SP Dimensions (For reference only: mm/in.)  
Order Guide  
Catalog Listing  
Description  
KGZ-10  
Oxygen sensor, flange mount with tabs  
Oxygen sensor, flange mount with pins  
KGZ-10SP  
Honeywell Sensing and Control  
3
WARNING  
PERSONAL INJURY  
WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
Failure to comply with these instructions could result in  
death or serious injury.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
WARRANTY/REMEDY  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Honeywell’s  
standard product warranty applies unless agreed to otherwise  
by Honeywell in writing; please refer to your order  
SALES AND SERVICE  
Honeywell serves its customers through a worldwide network  
of sales offices, representatives and distributors. For  
application assistance, current specifications, pricing or name  
of the nearest Authorized Distributor, contact your local sales  
office or:  
acknowledgement or consult your local sales office for specific  
warranty details. If warranted goods are returned to Honeywell  
during the period of coverage, Honeywell will repair or replace,  
at its option, without charge those items it finds defective. The  
foregoing is buyer’s sole remedy and is in lieu of all other  
warranties, expressed or implied, including those of  
merchantability and fitness for a particular purpose. In no  
event shall Honeywell be liable for consequential, special,  
or indirect damages.  
E-mail: info.sc@honeywell.com  
Internet: www.honeywell.com/sensing  
Phone and Fax:  
Asia Pacific +65 6355-2828  
+65 6445-3033 Fax  
While we provide application assistance personally, through  
our literature and the Honeywell web site, it is up to the  
customer to determine the suitability of the product in the  
application.  
Europe  
+44 (0) 1698 481481  
+44 (0) 1698 481676 Fax  
Latin America +1-305-805-8188  
+1-305-883-8257 Fax  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this  
printing. However, we assume no responsibility for its use.  
USA/Canada +1-800-537-6945  
+1-815-235-6847  
+1-815-235-6545 Fax  
Sensing and Control  
Honeywell  
1985 Douglas Drive North  
100458-3-EN IL50 GLO Printed in USA  
February 2011  
Copyright © 2011 Honeywell International Inc. All rights reserved.  
Golden Valley, MN 55422  
www.honeywell.com/sensing  

相关型号:

KGZ10-SP

Oxygen Sensors
HONEYWELL

KH-39-12

RF HN Connector
WINCHESTER

KH-59-13

RF Connector
WINCHESTER

KH-59-24

PL, ANG, HN
WINCHESTER

KH-59-26

PLUG, ANGLE, HN
WINCHESTER

KH-59-64

RF HN Connector
WINCHESTER

KH-59-66

RF SHV Connector
WINCHESTER

KH-59-72

HN PLUG
WINCHESTER

KH-59-78

RF HN Connector
WINCHESTER

KH-59-84

PLUG, ANGLE, HN
WINCHESTER

KH-79-15

RF HN Connector, 1 Contact(s), Receptacle
WINCHESTER

KH-99-09

ADAPTER, F-M, N-HN
WINCHESTER