Honeywell Pressure Switches
50094081
HP, HE, MH, ME, LP, LE, 5000, and 1000 Series
Issue 5
Datasheet
DESCRIPTION
FEATURES
The Honeywell Pressure Switch portfolio consists of:
• High Pressure (HE/HP Series)
• Medium Pressure (ME/MH Series)
• Low Pressure (LE/LP Series)
• 5000 Series, 1000 Series
• Pressure switching set point range: 3.5 psi to 4500 psi
• Proof pressure: from 500 psi up to 10,000 psi
• Burst pressure: from 1250 psi up to 20,000 psi
• Life cycle rating up to 2 million
• IP67 sealing rating4
• Operating temperature: -40 °C to 120 °C [-40 °F to 248 °F]
• Hysteresis option5
These pressure switches are durable, reliable
electromechanical gauge pressure on/off switches that are
available with either single pole single throw (SPST) normally
open or normally closed circuitry, or single pole double throw
(SPDT) circuitry. Their high proof pressure and burst pressure
ratings can allow for use in many rugged applications that
require the making or breaking of an electrical connection in
response to a pressure change of the system media.
• More than 15 pressure port options and over 30 electrical
terminations
• Plated steel, brass or stainless steel options3
• Switching point accuracy up to 2 ꢀ
POTENTIAL APPLICATIONS
DIFFERENTIATION
• Through optional smart diagnostic technology,
Honeywell pressure switches are able to detect failures
such as open circuits, cut wires, worn insulation, and
more6
• Optional smart diagnostic technology allows up to four
segregated signal amplitudes to perform diagnostics and
status6
• Pressure port snubber suppresses pressure spikes2
• IP67 sealing provides enhanced durability in harsh
environmental and washing applications1
• Agricultural machinery
• Heavy duty construction
machinery and trucks
• Lawn & garden machinery
• Marine vessels
• Material handling
machinery
• Railway
• CNC machines
• Compressors/boilers
• Fracking equipment
• Food & beverage equipment
• Generators
• HVAC/R equipment
• Mud pumps
• Pneumatic equipment
• Presses/punches
• Pressure washers
• Trash compactors
• Water pumps & jet cutting
machines
VALUE TO CUSTOMERS
• Designed to provide resistance to corrosion and enhances
equipment life with available two million life cycle rating and
IP67 rating1
• Can expedite design and product cycle due to ability to
receive samples in two weeks and production units in four
weeks
• Can reduce tooling, service, and manufacturing labor costs
due to standard connections, extended product life, and
expedited design and production cycle
PORTFOLIO
Honeywell also offers the PBN1 Series and PBN3 Series
Pressure Sensor.
1 HP, HE, MH, ME, LP, LE Series
2 HP, HE Series
3 ME, MH, LP, LE Series
4 HP, HE, LP, LE, ME Series
5 HP, HE, LP Series
6 HP, HE, ME, LP, LE Series
Safety and Productivity Solutions
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
Table 1. Specifications
Character-
istic
HP Series
HE Series
ME Series
MH Series
LP Series
LE Series
5000 Series 1000 Series
Product
length (various
terminations)
see pages 5 and 6
see page 5
see page 8
see page 7
see page 9
see page 9
see page 10
–
Product length
(blade)
Product length
(#8-32 screws)
Product length
(Metripack)
58,42 mm
[2.3 in]
60,96 mm
[2.4 in]
73,66 mm
[2.9 in]
65,6 mm
see pages 5 and 6
see pages 5 and 6
see pages 5 and 6
27 mm
see page 5
see page 5
see page 5
27 mm
see page 8
see page 8
see page 8
27 mm
see page 7
see page 7
see page 7
27 mm
see page 9
see page 9
see page 9
27 mm
see page 9
see page 9
see page 9
27 mm
[2.583 in]
–
–
0.50 in (steel)
0.437 in (brass)
M10 x 1.25 banjo
fitting
Hex size
Ease of
18 mm open
spanner
box spanner
yes
box spanner
yes
box spanner
no
box spanner
no
box spanner
yes
box spanner
no
1/2 in open spanner
installation
Snapꢁaction
switch
Set point1
range
Set point
ranges
no
no
10 psi to 60 psi
[0,69 bar to 2,7 bar]
100 psi to 4500 psi 150 psi to 4500 psi 25 psi to 350 psi
6 (Base Style A)
40 psi to 500 psi
4
3.5 psi to 150 psi
4
3.5 psi to 150 psi
4
75 psi to 150 psi
8
6
4
–
7 (Base Style B)
0.5 psi to 1 psi
( 0.3 psi)ꢁ
40 psi to 70 psi
( 7 psi)ꢁ
1.1 psi to 3 psi
( 0.5 psi)ꢁ
25 psi to 50 psi
( 3 psi)ꢁ
100 psi to 150 psi 150 psi to 1000 psi
>70 psi to 130 psi
( 10 psi)ꢁ
3.1 psi to 7 psi
( 1 psi)ꢁ
( 10 ꢀ)ꢁ
150 psi to 500 psi
( 6 ꢀ)ꢁ
( 14ꢀ)ꢁ
1000 psi to
2000 psi
>50 psi to 100 psi
( 7 psi)ꢁ
Set point
accuracy
@ 25 °C
>130 psi to 200 psi
( 15 psi)ꢁ
3.5 psi to 10 psi ( 1 psi)ꢁ
8 psi to 13 psi
( 2 psi)ꢁ
20 psi 10 psiꢁ
58 psi 20 psi
>100 psi to 150 psi
( 10 psi)ꢁ
>10 psi to 50 psi ( 3 psi)ꢁ
>50 psi to 100 psi ( 7 psi)ꢁ
>100 psi to 150 psi ( 10 psi)
501 psi to 4000 psi
( 3.5 ꢀ)ꢁ
( 12 ꢀ)ꢁ
>200 psi to 280 psi
( 20 psi)ꢁ
14 psi to 24 psi
( 3 psi)ꢁ
2000 psi to
4000 psi
( 11 ꢀ)ꢁ
(before test)
>150 psi to 250 psi
( 13 psi)ꢁ
4000 psi to 4500
psi
>280 psi to 350 psi
( 30 psi)ꢁ
25 psi to 50 psi
( 5 psi)ꢁ
>250 psi to 350 psi
( 16 psi)
( 2 ꢀ)
>4000 psi ( 10 ꢀ)
>350 psi to 500 psi
( 40 psi)
51 psi to 90 psi
( 7 psi)ꢁ
91 psi to 150 psi
( 10 psi)
0.5 psi to 3 psi
( 1.5 psi)ꢁ
40 psi to 70 psi
( 6 psi)ꢁ
25 psi to 50 psi
(20 psi)ꢁ
4 psi to 7 psi
( 2.5 psi)ꢁ
>70 psi to 130 psi
( 10 psi)ꢁ
3.5 psi to 10 psi
>50 psi to 100 psi
(30 psi)ꢁ
( 2.8 psi)ꢁ
>10 psi to 50 psi
( 14 psi)ꢁ
8 psi to 13 psi
( 3.5 psi)ꢁ
>130 psi to 200 psi
( 15 psi)ꢁ
Average deadꢁ
band max.
>100 psi to 150 psi
(40 psi)ꢁ
14 psi to 24 psi
( 8 psi)ꢁ
n/a
n/a
n/a
n/a
>200 psi to 280 psi
( 20 psi)ꢁ
>50 psi to 100 psi
( 38 psi)ꢁ
>100 psi to 150 psi
( 40 psi)
>150 psi to 250 psi
(50 psi)ꢁ
25 psi to 50 psi
( 15 psi)ꢁ
>280 psi to 350 psi
( 30 psi)ꢁ
>250 psi to 350 psi
(60 psi)
51 psi to 90 psi
( 23 psi)ꢁ
>350 psi to 500 psi
( 40 psi)
91 psi to 150 psi
( 40 psi)
Operating
pressure2
1400 psi
5,000 psi max.
5,000 psi max.
500 psi max.
4,000 psi
600 psi max.
6,000 psi
250 psi max.
500 psi
250 psi max.
500 psi
150 psi, 250 psi
[96,5 bar] max.
10,000 psi (Base
Style A)
6,500 psi (Base
Style B)
2973 psi
[205 bar]
Proof pressure3
Hysteresis
10,000 psi
500 psi
5 ꢀ to 55 ꢀ
3 ꢀ to 65 ꢀ
5 ꢀ to 55 ꢀ
(based on set point
range)
(based on set point (based on set point
n/a
n/a
n/a
n/a
n/a
range)
range)
20,000 psi (Base
3500 psi
[241 bar]
Burst pressure4 Style A)ꢁ 9,000 psi
20,000 psi
8,000 psi
9,000 psi
1250 psi
1250 psi
4000 psi
(Base Style B)
15 A, 6 Vdcꢁ
8 A, 12 Vdcꢁ
4 A, 24 Vdc
Current rating
(resistive)
5 A at 250 Vac
5 A at 24 Vdc
3 A at 250 Vac
3 A at 24 Vdc
7.5 mA to 3 A,
7.5 mA to 5 A,
7.5 mA to 3 A,
12 Vdc with two-
100 mA to 3 A max.
n/a
24 Vdc and 250 Vac
24 Vdc and 250 Vac 24 Vdc and 250 Vac
1157 bulbs (4.4 A)
Current rating
(inductive)
5 A at 115 Vac (SX
rating)ꢁ 3 A at 28 Vdc
1 A, 120 Vac
0.5 A, 240 Vac
n/a
n/a
1 A at 28 Vdc
n/a
n/a
8Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A.
Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A.
Port Styles A, B, E, M, P, T, and Y will use Base Style B.
Switches less than 150 psi will only use Base Style B.
2
sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
Character-
istic
HP Series
HE Series
ME Series
MH Series
LP Series
LE Series
5000 Series 1000 Series
Rated thermal
current
5 A
3 A
3 A
n/a
n/a
5 A
3 A
n/a
n/a
n/a
n/a
Rated insulaꢁ
tion voltage
28 V
28 V
28 V
28 V
28 V
Shortꢁcircuit
protective
Class J fuse (10 A, 600 V)
1000 A
n/a
Class J fuse (10 A, 600 V)
n/a
n/a
device cꢁtype
max. rating
Conditional
short circuit
current
n/a
n/a
1000 A
1000 A
n/a
n/a
n/a
n/a
Pollution
degree
3 (macro environment)
ꢂ40 °C to 85 °C
3 (macro environment)
Temperature
rating
ꢂ40 °C to 120 °C
ꢂ40 °C to 121 °C
[ꢂ40 °F to 250 °F]
ꢂ20 °C to 74 °C
[ꢂ4 °F to 165 °F]
ꢂ40 °C to 120 °C [ꢂ40 °F to 248 °F]
[ꢂ40 °F to 248 °F] [ꢂ40 °F to 185 °F]
Media
connection
multiple ports
available
multiple ports
available
1/8ꢂ27 NPT male
thread
multiple ports
available
multiple ports available
A = 1/4ꢂ18 NPT
A = 1/4ꢂ18 NPT
B = 1/8ꢂ27 NPT
C = 1/2ꢂ20 UNF
D = 1/8ꢂ27 PTF
E = M12 × 1.5
B = 1/8ꢂ27 NPT
C = 1/2ꢂ20 UNF
D = 1/8ꢂ27 PTF
E = M12 × 1.5
A = 1/4ꢂ18 NPT
B = 1/8ꢂ27 NPT
C = 1/2ꢂ20 UNF
D = 1/8ꢂ27 PTF
E = M12 × 1.5
A = 1/4ꢂ18 NPT
B = 1/8ꢂ27 NPT
C = 1/2ꢂ20 UNF
D = 1/8ꢂ27 PTF
E = M12 × 1.5
F = M14 × 1.5
C = 1/2ꢂ20 UNF
F = M14 × 1.5
F = M14 × 1.5
G = 9/16ꢂ18 UNF
H = 3/4ꢂ16 UNF
J = G1/8 BSPP
L = 3/8ꢂ24 UNF
F = M14 × 1.5
F = M14 × 1.5
M10 x 1.25 double
banjoꢁ
Refer to product
G = 9/16ꢂ18 UNF
H = 3/4ꢂ16 UNF
J = G1/8 BSPP
G = 9/16ꢂ18 UNF
H = 3/4ꢂ16 UNF
J = G1/8 BSPP
G = 9/16ꢂ18 UNF
H = 3/4ꢂ16 UNF
J = G1/8 BSPP
G =9/16ꢂ18 UNF
H = 3/4ꢂ16 UNF
K = M18 × 1.5
Pressure ports nomenclature for
1/8ꢂ27 NPT
M10 x 1ꢁ
pressure port types.
1/8ꢂ27 NPT
M = 7/16ꢂ20 UNF M = 7/16ꢂ20 UNF M = 7/16ꢂ20 UNF M = 7/16ꢂ20 UNF
N = 7/8ꢂ14 UNF
R = R1/8 BSPT
T = M10 × 1.0
V = R1/2 BSPT
Y = G1/4 BSPP
Z = R1/4 BSPT
P = 1/2ꢂ14 NPT
R = R1/8 BSPT
T = M10 × 1.0
V = R1/2 BSPT
Y = G1/4 BSPP
Z = R1/4 BSPT
R = R1/8 BSPT
T = M10 × 1.0
V = R1/2 BSPT
Y = G1/4 BSPP
Z = R1/4 BSPT
R = R1/8 BSPT
T = M10 × 1.0
V = R1/2 BSPT
Y = G1/4 BSPP
Z = R1/4 BSPT
Circuit forms5
SPDT, SPST - NO/NC
SPDT, SPST - NO/NC
SPST - NO/NC
–
SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPSTꢂNOꢁ SPSTꢂNC
SPNO
–
Smart pressure
single- or dual-resistor topology available
single- or dual-resistor topology available
–
2 million (Base A)
1 million (Base B)
Life
1 million
1 million
1 million
2 million
1 million
100,000 cycles
100,000 cycles
Agency approvꢁ
als (special use
switches)
UL Custom
(select models)
–
–
–
–
–
–
–
Agency approvꢁ
als (other)
CE
no
CE
CE
CE
CE
CE
–
–
Field
no
yes
no
yes
no
yes
no
yes
no
yes
no
no
no
adjustability6
Spike
dampening
yes
yes
IP67 (connecetors)
IP67 (connectors)
IP67 (wire out)
IP00 (blade/screw)
IP67 (connectors)
IP67 (wire out)
IP67 (connectors)
IP67 (wire out)
Ingress
IP67 (wire/Base A) IP67 (connectors)
IP69K (wire/Base B) IP00 (blade/screw)
IP00 (blade/screw)
IP67 (connectors)
IP00 (blade/screw)
IP00
–
IP65
protection7
IP00 (blade/screw) IP00 (blade/screw)
Vibration
resistance
swept sine: 10 Hz to 2000 Hz at 15 g, 20 min/sweepꢁ 8 hours in each axis
random: 5 Hz to 2000 Hz, 8 hours/axisꢁ 14,88 gꢂRMS, each axis
–
Shock
500 m/sec2, 11 mSEC, 100 shocks / axis
500 m/sec2, 11 mSEC
15 G @ 5 mSEC
EPDM
resistance
Wetted part
(diaphragm)
Kapton®
Kapton®
n/a
Nitrile/EPDM/LTNB
Tefzel®
Polymide film
(Teflon® coated)
(Teflon® coated)
Wetted part
(piston)
nitrile or EPDM
o-ring
nitrile or EPDM
o-ring
nitrile or EPDM
o-ring
nitrile or EPDM
o-ring
nitrile or EPDM
o-ring
nitrile o-ring, steel piston
EPDM
133 g [4.7 oz] (Base Style A)
178 g [6.28 oz] (Base Style B)
Weight
53 g [1.9 oz]
gold plated
53 g [1.9 oz]
gold plated
58 g [2.0 oz]
gold plated
53 g [1.9 oz]
gold plated
65 g [2.3 oz]
40 g [1.4 oz]
Contacts
silver / gold inlay
silver
silver-plated copper silver-plated copper
Rynite 545 glass
glass reinforced
filled (housing)ꢁ
Product finish
zinc plating
zinc plating
zinc plating
zinc plating
zinc plating
zinc plating
polyester (housing)ꢁ
Travalent plated steel
plated steel (base)
(base)
1Set point: Point at which switch actuates or deꢁactuates
2Operating pressure: Maximum normal system operating pressure
3Proof pressure: Maximum pressure that the switch can handle while it maintains set point accuracy. Intermittent spikes to this level are acceptable.
4Burst pressure: Point of complete switch failure
5SPST: Single pole, single throw. SPDT: Single pole, double throw. NO: Normally open. NC: Normally closed.
6Field adjustability only available with AA, BA, CA, and DA (SPST only) terminations.
7IP00 for AA and BA terminations.
Safety and Productivity Solutions
3
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
Table 2. Terminations
Series
Available Terminations
AA = Spade Terminals
BA = Screw Terminals
CA = Deutsch DT04-3P-E005 (3-Pin Connector)
DA = Amp Super Seal 1.5 ꢁ 282105-1 (3-Pin Connector)
EA = 10ꢁinch Cable, 18 AWG (Wire Out, No Connector)
FA = 10ꢁinch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)*
GA = 10ꢁinch Cable w/Amp Super Seal 1.5 ꢁ 282105-1 (3-Pin Connector) (18 AWG)*
HA = 10ꢁinch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)*
JA = 10ꢁinch Cable w/Din43650-C (3-Pin Connector) (18 AWG)*
KA = 10ꢁinch Cable w/M12x1 (Brad Harrison Micro) ꢁ 21032121306 Harting P/N (3-Pin Connector) (18 AWG)*
LA = 10ꢁinch Cable w/Packard Weatherpack Male Terminal ꢁ 12020827 (3-Pin Connector) (18 AWG)*
MA = 10ꢁinch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG)
NA = 3ꢁinch Cable w/Packard 2P Tower Connector ꢁ 12015792 (2-Pin Connector) (18 AWG)
PA = 2.75ꢁinch Cable w/Packard 2P Shroud Connector ꢁ 12010973 (2-Pin Connector) (18 AWG)
RA = 4ꢁinch Cable w/Packard 2P Shroud Connector ꢁ 12010973 (2-Pin Connector) (16 AWG)
SA = 5.5ꢁinch Cable w/ITT Cannon 2P Sure-Seal Circular Connector ꢁ SS2R-120-1804-000 (2-Pin Connector) (18 AWG)
TA = 8.5ꢁinch Cable w/ITT Cannon 3P Sure-Seal Circular Connector ꢁ SS3R-120-8551-001 (3-Pin Connector) (16 AWG)*
UA = 10ꢁinch Cable ꢁ Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)*
VA = 10ꢁinch Cable ꢁ Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)*
WA = 4.5ꢁinch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)*
HP, HE, ME,
LP, LE
XA = 10ꢁinch Cable w/ Metripack 2-Pin Shroud Connector 153000027 (18 AWG)
YA = 6ꢁinch Cable w/Amp Super Seal 1.5 ꢁ 282104-1 (2-Pin Connector) (18 AWG)*
ZA = 10ꢁinch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG)
AB = Deutsch DT04-2P-E005 (2-Pin Connector)
BB = 10ꢁinch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)*
CB = 6ꢁinch Cable w/ AMP Super Seal 1.5 ꢁ 282080-1 (2-Pin Connector) (18 AWG)
DB = 10ꢁinch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)*
EB = 4.5ꢁinch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG)
FB = 10ꢁinch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG)
GB = 8.5ꢁinch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG)
AA = Spade Terminals
BA = Screw Terminals
DA = Amp Super Seal 1.5 ꢁ 282105-1 (3-Pin Connector)
EA = 10ꢁinch Cable, 18 AWG (Wire Out, No Connector)
HA = 10ꢁinch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)*
MA = 10ꢁinch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG)
NA = 3ꢁinch Cable w/Packard 2P Tower Connector ꢁ 12015792 (2-Pin Connector) (18 AWG)
PA = 2.75ꢁinch Cable w/Packard 2P Shroud Connector ꢁ 12010973 (2-Pin Connector) (18 AWG)
RA = 4ꢁinch Cable w/Packard 2P Shroud Connector ꢁ 12010973 (2-Pin Connector) (16 AWG)
SA = 5.5ꢁinch Cable w/ITT Cannon 2P Sure-Seal Circular Connector ꢁ SS2R-120-1804-000 (2-Pin Connector) (18 AWG)
WA = 4.5ꢁinch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)*
XA = 10ꢁinch Cable w/ Metripack 2-Pin Shroud Connector 153000027 (18 AWG)
YA = 6ꢁinch Cable w/Amp Super Seal 1.5 ꢁ 282104-1 (2-Pin Connector) (18 AWG)*
ZA = 10ꢁinch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG)
AB = Deutsch DT04-2P-E005 (2-Pin Connector)
MH
CB = 6ꢁinch Cable w/ AMP Super Seal 1.5 ꢁ 282080-1 (2-Pin Connector) (18 AWG)
DB = 10ꢁinch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)*
EB = 4.5ꢁinch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG)
FB = 10ꢁinch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG)
*These connectors are designed for dual circuit (SPDT) by default. They can be used for singleꢁcircuit applications (SPNC/SPNO) by making suitꢁ
able connections. Refer to wiring diagram.
4
sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS ꢀ HIGH PRESSURE: HP SERIES (BASE STYLE A), HE SERIES
Base Style A key specifications • Life: 2 million (HP), 1 million (HE); Burst pressure: 20,000 psi
Figure 1. AMP Superseal 1.5
20,02 mm
61,64 mm
[2.427 in]
[0.788 in]
27 mm
[1.063] hex A/F
(bottom view)
(top view)
Female Connector Part Number (included): Cꢂ282105
Male Mating Connector (customer provided): Cꢂ282087
IP Rating: IP67
Figure 2. Deutsch
61,64 mm
[2.427 in]
21,16 mm
[0.833 in]
27 mm
[1.063] hex A/F
(bottom view)
(top view)
Female Connector Part Number (included): DT04ꢂ3P
Male Mating Connector (customer provided): DT06ꢂ3S
IP Rating: IP67
Figure 3. Spade Terminal
27 mm
61,64 mm
[2.427 in]
14,43 mm
[0.568 in]
[1.063] hex A/F
(bottom view)
(top view)
Figure 4. Screw Terminal
61,64 mm
[2.427 in]
12,65 mm
[0.498 in]
27 mm
[1.063] hex A/F
(bottom view)
(top view)
Figure 5. Cable
61,64 mm
[2.427 in]
19,51 mm
[0.768 in]
27 mm
[1.063] hex A/F
(bottom view)
(top view)
IP Rating: IP67
Safety and Productivity Solutions
5
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS ꢀ HIGH PRESSURE: HP SERIES (BASE STYLE B)
Base Style B key specifications • Life: 1 million; Burst pressure: 9,000 psi
Figure 6. HP Series Base Style B
71,47 mm
[2.814 in]
14,43 mm
[0.568 in]
HP with smaller port: dimension 2.814 in remains same
(bottom view)
for all base ports.
Figure 7. HP Series Pressure Port Dimensions
“H”
Thread
“H”
Thread
“Ø D”
“Ø D”
“A”
“H”
Thread
“Ø D”
“Ø C”
Table 3. HP/HE Series Pressure Port Diameters and Heights
Nomenclature Code
Thread
7/16-20 UNF
1/2-20 UNF
9/16-18 UNF
3/4-16 UNF
7/8-14 UNF
M10 x 1.0
Height “A”
Diameter “ØD”
9,25 mm [0.364 in]
10,85 mm [0.427 in]
12,24 mm [0.482 in]
16,74 mm [0.66 in]
19,6 mm [0.773 in]
9,25 mm [0.364 in]
10,85 mm [0.427 in]
12,24 mm [0.482 in]
16,74 mm [0.66 in]
10,29 mm [0.405 in]
13,72 mm [0.540 in]
Diameter “ØC”
Height “H”
11 mm [0.433 in]
11 mm [0.433 in]
12 mm [0.472 in]
14 mm [0.551 in]
16 mm [0.630 in]
11 mm [0.433 in]
11 mm [0.433 in]
12 mm [0.472 in]
14 mm [0.551 in]
12,497 mm [0.492 in]
17,63 mm [0.694 in]
M
C1
G2
H
N
T
–
–
–
–
–
–
–
–
–
–
1,60 mm [0.063 in]
2,48 mm [0.098 in]
2,48 mm [0.098 in]
2,48 mm [0.098 in]
–
13,79 mm [0.543 in]
16,79 mm [0.661 in]
18,8 mm [0.74 in]
23,8 mm [0.937 in]
–
E
F2
M12 x 1.5
M14 x 1.5
K
M18 x 1.5
B
1/8-27 NPT
1/4-18 NPT
A
–
–
1Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A.
2Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A.
Switches less than 150 psi will use only Base Style B.
6
sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS ꢀ MEDIUM PRESSURE: MH SERIES
Figure 8. AMP Superseal 1.5
Figure 13. MH Series Pressure Port Dimensions
67,06 mm max.
[2.64 in] max.
(bottom view)
Figure 9. Deutsch 2-pin
“A”
67,06 mm max.
[2.64 in] max.
Table 4. MH Series Pressure Port Diameters and Heights
(bottom view)
Port
Diameter “ØD”
21,34 mm [0.840 in]
13,46 mm [0.530 in]
9,96 mm [0.392 in]
10,34 mm [0.407 in]
13,72 mm [0.540 in]
10,29 mm [0.405 in]
11,1 mm [0.437 in]
8,28 mm [0.326 in]
16,74 mm [0.659 in]
9,25 mm [0.364 in]
12,24 mm [0.482 in]
10,85 mm [0.427 in]
Height “H”
R 1/2 BSPT
R 1/4 BSPT
R 1/8 BSPT
1/8-27 PTF
1/4-18 NPT
1/8-27 NPT
G 1/4 BSPP
G 1/8 BSPP
3/4-16 UNF
7/16-20 UNF
9/16-18 UNF
1/2-20 UNF
17,09 mm [0.673 in]
13,74 mm [0.541 in]
10,24 mm [0.403 in]
9,24 mm [0.364 in]
17,63 mm [0.694 in]
12,497 mm [0.492 in]
11,20 mm [0.441 in]
7,59 mm [0.299 in]
11,1 mm [0.437 in]
9,09 mm [0.358 in]
10,00 mm[0.394 in]
9,09 mm [0.358 in]
Figure 10. Wire out
(bottom view)
50,29 mm max.
[1.98 in] max.
Figure 11. Blade terminal
Height
“A”
Diameter Diameter
Port
Height “H”
“ØC”
“ØD”
38,35 mm max.
[1.51 in] max.
2,49 mm
[0.098 in]
18,8 mm
[0.74 in]
11,71 mm 10,998 mm
(bottom view)
M14 × 1.5
M12 × 1.5
M10 × 1.0
[0.461 in]
[0.433 in]
Figure 12. Screw terminal
2,49 mm
[0.098 in]
16,79 mm
[0.661 in]
9,70 mm
[0.382 in]
10,998 mm
[0.433 in]
1,6 mm
[0.063 in]
13,79 mm
[0.543 in]
8,41 mm
[0.331 in]
8,51 mm
[0.335 in]
38,35 mm max.
[1.51 in] max.
(bottom view)
Safety and Productivity Solutions
7
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS ꢀ MEDIUM PRESSURE: ME SERIES
Figure 20. ME Series Pressure Port Dimensions
Figure 14. AMP Superseal 1.5
H
H
65,3 mm max.
[2.57 in] max.
ØD
(bottom view)
Female connector part number (included): C-282105
ØD
Male mating connector (customer provided): C-282087
IP rating: IP67
Figure 15. Deutsch 3-pin
A
H
ØD
64 mm max.
ØC
[2.52 in] max.
(bottom view)
Female connector part number (included): DT04-3P
Male mating connector (customer provided): DT06-3S
IP rating: IP67
Table 5. ME Series Pressure Port Diameters and Heights
Port
Diameter “ØD”
21,34 mm [0.840 in]
13,46 mm [0.530 in]
9,96 mm [0.392 in]
10,34 mm [0.407 in]
13,72 mm [0.540 in]
10,29 mm [0.405 in]
11,1 mm [0.437 in]
8,28 mm [0.326 in]
16,74 mm [0.659 in]
9,25 mm [0.364 in]
12,24 mm [0.482 in]
10,85 mm [0.427 in]
Height “H”
Figure 16. Deutsch 2-pin
R 1/2 BSPT
R 1/4 BSPT
R 1/8 BSPT
1/8-27 PTF
1/4-18 NPT
1/8-27 NPT
G 1/4 BSPP
G 1/8 BSPP
3/4-16 UNF
7/16-20 UNF
9/16-18 UNF
1/2-20 UNF
17,09 mm [0.673 in]
13,74 mm [0.541 in]
10,24 mm [0.403 in]
9,24 mm [0.364 in]
17,63 mm [0.694 in]
12,497 mm [0.492 in]
11,20 mm [0.441 in]
7,59 mm [0.299 in]
11,1 mm [0.437 in]
9,09 mm [0.358 in]
10,00 mm[0.394 in]
9,09 mm [0.358 in]
65,5 mm max.
[2.58 in] max.
(bottom view)
Female connector part number (included): DT04-2P
Male mating connector (customer provided): DT06-2S
IP rating: IP67
Figure 17. Wire out
48,51 mm max.
[1.91 in] max.
(bottom view)
Height
Diameter Diameter
IP rating: IP67
Port
Height “H”
“A”
“ØC”
“ØD”
Figure 18. Blade terminal
2,49 mm
[0.098 in]
18,8 mm
[0.74 in]
11,71 mm 10,998 mm
[0.461 in]
M14 × 1.5
M12 × 1.5
M10 × 1.0
[0.433 in]
2,49 mm
[0.098 in]
16,79 mm
[0.661 in]
9,70 mm
[0.382 in]
10,998 mm
[0.433 in]
1,6 mm
[0.063 in]
13,79 mm
[0.543 in]
8,41 mm
[0.331 in]
8,51 mm
[0.335 in]
38,9 mm max.
[1.57 in] max.
(bottom view)
Figure 19. Screw terminal
38,9 mm max.
[1.57 in] max.
(bottom view)
8
sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS ꢀ LOW PRESSURE: LP SERIES, LE SERIES
Figure 21. AMP Superseal 1.5
Figure 27. LP/LE Series Pressure Port Dimensions
H
H
58,93 mm max.
[2.32 in] max.
ØD
(bottom view)
ØD
Figure 22. Deutsch 3-pin
A
H
ØD
ØC
57,66 mm max.
[2.27 in] max.
(bottom view)
Table 6. LP/LE Series Pressure Port Diameters and Heights
Figure 23. Deutsch 2-pin
Port
Diameter “ØD”
21,34 mm [0.840 in]
13,46 mm [0.530 in]
9,96 mm [0.392 in]
10,34 mm [0.407 in]
13,72 mm [0.540 in]
10,29 mm [0.405 in]
11,1 mm [0.437 in]
8,28 mm [0.326 in]
16,74 mm [0.659 in]
9,25 mm [0.364 in]
12,24 mm [0.482 in]
10,85 mm [0.427 in]
Height “H”
R 1/2 BSPT
R 1/4 BSPT
R 1/8 BSPT
1/8-27 PTF
1/4-18 NPT
1/8-27 NPT
G 1/4 BSPP
G 1/8 BSPP
3/4-16 UNF
7/16-20 UNF
9/16-18 UNF
1/2-20 UNF
17,09 mm [0.673 in]
13,74 mm [0.541 in]
10,24 mm [0.403 in]
9,24 mm [0.364 in]
17,63 mm [0.694 in]
12,497 mm [0.492 in]
11,20 mm [0.441 in]
7,59 mm [0.299 in]
11,1 mm [0.437 in]
9,09 mm [0.358 in]
10,00 mm [0.394 in]
9,09 mm [0.358 in]
58,93 mm max.
[2.32 in] max.
(bottom view)
Figure 24. Wire out
42,16 mm max.
[1.66 in] max.
(bottom view)
IP rating: IP67
Height
“A”
Diameter Diameter
Port
Height “H”
Figure 25. Spade terminal
“ØC”
“ØD”
2,49 mm
[0.098 in]
18,8 mm
[0.74 in]
11,71 mm 10,998 mm
M14 × 1.5
M12 × 1.5
M10 × 1.0
[0.461 in]
[0.433 in]
2,49 mm
[0.098 in]
16,79 mm
[0.661 in]
9,70 mm
[0.382 in]
10,998 mm
[0.433 in]
1,6 mm
[0.063 in]
13,79 mm
[0.543 in]
8,41 mm
[0.331 in]
8,51 mm
[0.335 in]
33,02 mm max.
[1.30 in] max.
(bottom view)
Figure 26. Screw terminal
(bottom view)
33,02 mm max.
[1.30 in] max.
Safety and Productivity Solutions
9
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS ꢀ 1000 SERIES, 5000 SERIES
Figure 28. 1000 Series Dimensions
11,18 mm [0.44 in] min.
last full thread ref.
12,4 mm
[0.488 in]
6,02 mm
[0.237 in]
33,1 mm
[1.303 in]
31,5 mm
[1.24 in]
65,6 mm
[2.583 in]
55,11 mm
[2.17 in]
34,85 mm
[1.37 in]
5,5 mm
[0.22 in]
M 10 x 1.25 ꢀ6G
45°
45°
2X 9,91 mm
[0.39 in]
3,2 mm
[0.13 in]
8,99 mm
[0.35 in]
1,5 x 45°
Ø2,5 cross drill
0.25 x 45° chamfer
2,1 mm
[0.08 in]
Figure 29. 5000 Series Dimensions
8ꢀ32 x 1/4 screw (3)
1/8ꢀ27 NPT
0.500 hex ref.
Ø 37,34 mm
[Ø 1.47 in]
ref.
58,42 mm
[2.3 in] ref.
10 sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
NOMENCLATURE: HIGH PRESSURE
For example, HPR05500PFNSPAAA01 defines a high pressure switch, rising factory set, nonꢁadjustable set point, 550 psi set
point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO silver contacts output, coldꢁrolled steel base, glycolꢁbased
fluid (EPDM) actuation/application, spade terminal connectors, standard switch, individually boxed units.
P
N
S
HP
R
P
F
A
01
AA
05500
Pressure
Set Point
Actuation/
Application
Connector
Type
Pressure
Unit
Packaging
Options
Port Type
Output
Base
Series
Set Point
Options
Petroleum-based
hydraulic fluid
(Nitrile)
HP Series
HE Series
(100 psi to
4500 psi),
High
Rising
Cold-rolled
steel
Standard
switch
1/4 in Spade
Terminals*
Individually
boxed units*
6,89 bar to 310,26 bar
[100 psi to 4500 psi]
psig,
sealed gage
SPST-NO,
silver contacts
1/4-18 NPT
factory set,
non-adjustable
S
01
02
R
F
A
B
C
N
P
A
B
C
P
B
N
C
AA
BA
CA
DA
EA
FA
Falling
factory set,
non-adjustable
NOTE:
Pressure set point
is always five digits.
bar,
sealed gage
Screw
Terminals*
With 3 shrink
sleeve
Individually
boxed units**
Glycol-based
fluid (EPDM)
SPST-NC,
silver contacts
1/8-27 NPT
1/2-20 UNF
With shrink
sleeve
(plastic coating)
NOTE:
25 individual
EDPM O-ring option only available
from 100 psi to 250 psi.
SPDT-NO/NC,
silver contacts
Deutsch DT04-3P-E005
(3-Pin Connector)*
boxes packed in
Set point below 100 psi
is available only with
HP Series (Body Style B).
15 bulk packaging*
D
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as 01545.
This allows for 2 decimal
places.
Pressure
Switch
With shrink
sleeve
(acrylic coating)
25 individual
Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)*
NO, gold
inlay contacts
boxes packed in
M12 x 1.5
M14 x 1.5
D
F
H
16 bulk packaging**
E
F
50 individual
304,8 mm [12 in]
total wire length
10-inch Cable, 18 AWG
(Wire Out, No Connector)
NC, gold
inlay contacts
boxes packed in
20 bulk packaging*
J
K
E
F
50 individual
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
SPDT(NO/NC),
gold inlay
contacts
With conduit
sleeve
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
boxes packed in
9/16-18 UNF
21 bulk packaging**
G
H
G
H
K
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
NO, with 510 Ω/
0.5 W & 160 Ω/
0.5 W resistors
With Vibra seal for
port threads
25 units in
bulk packaging*
3/4-16 UNF
M18 x 1.5
25
GA
HA
JA
#8-32 screw with
external tooth
lockwasher***
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)
25 units in
bulk packaging**
NC, with 3000 Ω/
0.125 W resistor
J
26
50 individual
10-inch Cable w/
914,4 mm [36 in]
total wire length
parts in
7/16-20 UNF
Din43650-C
K
50 bulk packaging*
M
N
T
(3-Pin Connector) (18 AWG)*
304,8 mm [12 in]
total wire length with
acrylic sleeve
10-inch Cable w/M12x1
(Brad Harrison Micro) -
21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
* Not applicable for HP
Series (Base Style B)
7/8-14 UNF
M10 x 1.0
L
KA
** Not applicable for
HP (Base Style A) & HE Series
914,4 mm [36 in]
total wire length with
acrylic sleeve
M
10-inch Cable w/Packard
Weatherpack Male Terminal -
12020827 (3-Pin Connector)
(18 AWG)*
LA
MA
NA
*** For screw terminal option
only
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
HP Series Port Types
Thread Type
Base Style A
n/a
Base Style B
100 psi to 4500 psi
100 psi to 4500 psi
n/a
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
A = 1/4-18 NPT
B = 1/8-27 NPT
C = 1/2-20 UNF
E = M12 x 1.5
F = M14 x 1.5
n/a
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
PA
RA
SA
>975 psi
n/a
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
100 psi to 4500 psi
n/a
>350 psi
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
G = 9/16-18 UNF >350 psi
<350 psi
H = 3/4-16 UNF
K = M18 x 1.5
>150 psi
<150 psi
150 psi to 4500 psi n/a
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector -
SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
TA
M = 7/16-20 UNF n/a
100 psi to 4500 psi
100 psi to 4500 psi
N = 7/8-14 UNF
T = M10 x 1.0
150 psi to 4500 psi n/a
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
n/a
UA
VA
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
Port Type A, B, E, M, and T will be available only with HP Series.
Base Style B will be available only with HP Series
4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)
WA
XA
YA
ZA
BB
CB
DB
EB
FB
GB
10-inch Cable w/ Metripack
2-Pin Shroud Connector
153000027 (18 AWG)
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)
6-inch Cable w/ AMP Super
Seal 1.5 - 282080-1
(2-Pin Connector) (18 AWG)
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
8.5-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)*
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
Safety and Productivity Solutions 11
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
NOMENCLATURE: MEDIUM PRESSURE, HIGH BURST
For example, MHR01500PFPVMAAA01 defines a medium pressure, high burst switch, rising factory set, non-adjustable set
point, 150 psi set point, psig, sealed gage pressure unit, 1/4ꢀ18 NPT port type, SPSTꢀNO contacts output, stainless steel base,
LTNB diaphragm, and spade terminal connectors.
M
P
N
AA
MH
R
P
A
A
01
01500
Connector
Type
Pressure
Set Point
Actuation/
Application
Pressure
Unit
Packaging
Options
Port Type
Output
SPST-NO
Base
Series
Set Point
Options
MH Series
Medium
Pressure
Switch
Rising
factory set,
non-adjustable
Standard
switch
Cold-rolled
steel
1/4 in Spade
Terminals
LTNB diaphragm
Individually
01
boxed units
0,24 bar to 10,34 bar
[3.5 psi to 150 psi]
psig,
sealed gage
1/4-18 NPT
N
B
V
AA
BA
DA
EA
HA
MA
A
C
R
F
A
B
C
M
N
E
P
B
P
(Low-temp Buna N)
With shrink
sleeve
(plastic coating)
25 individual
Falling
factory set,
non-adjustable
HNBR diaphragm
(Hydrogenated Nitrile
Butadiene Rubber)
NOTE:
Screw
Terminals
bar,
sealed gage
boxes packed in
SPST-NC
Brass
1/8-27 NPT
M
15 bulk packaging
Pressure set point
is always five digits.
With shrink
sleeve
(acrylic coating)
Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)
EPDM diaphragm
(Ethylene-Propylene-
Diene Monomer)
bar,
true gage*
150 units in
bulk packaging
Rising,
field adjustable*
Stainless
steel
1/2-20 UNF
T
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as
01545. This allows for
2 decimal places.
20
25
M
T
D
F
25 units in
bulk packaging
Falling,
field adjustable*
10-inch Cable, 18 AWG
(Wire Out, No Connector)
psig,
true gage*
304,8 mm [12 in]
total wire length
C
1/8-27 PTF
D
* Field adjustable option is only
available for:
1. Blade and screw terminations
(SPDT, SPNO, SPNC)
2. Deutsch DT04-3P
(SPDT, SPNO, SPNC)
150 individual
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)*
psig,
With conduit
sleeve
boxes packed in
sealed gage
with epoxy**
30 bulk packaging
G
M12 x 1.5
M14 x 1.5
G
H
E
F
G
H
J
L
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
bar,
sealed gage
with epoxy**
With Vibra seal
for threads
H
J
3. Amp Superseal 1.5 (3-pin)
(SPNO & SPNC)
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
#8-32 screw with
external tooth
lockwasher***
*Blade and screw electrical
terminations are available
with only the the true gage
option.
9/16-18 UNF
3/4-16 UNF
G1/8 BSPP
NA
PA
RA
SA
WA
914,4 mm [36 in]
total wire length
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
K
L
**Connector cavity and roll
forming area filled with epoxy
to meet dunk test sealing
capability.
304,8 mm [12 in]
total wire length
w/ shrink sleeve
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
914,4 mm [36 in]
total wire length
w/ shrink sleeve
M
3/8-24 UNF
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
***applicable only for
screw terminal version.
7/16-20 UNF
M
P
R
T
V
4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)*
1/2-14 NPT
R1/8 BSPT
M10 × 1.0
10-inch Cable w/ Metripack
2-Pin Shroud Connector
153000287 (18 AWG)
XA
YA
ZA
AB
CB
DB
EB
FB
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
R1/2 BSPT
Deutsch DT04-2P-E005
(2-Pin Connector)
G1/4 BSPP
R1/4 BSPT
Y
Z
6-inch Cable with Amp
Super Seal 1.5 - 282080-1
(2-Pin Connector) (18 AWG)
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
12 sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
NOMENCLATURE: MEDIUM PRESSURE
For example, MER01500PFPVKAAA01 defines a medium pressure switch, rising factory set, non-adjustable set point, 55 psi set
point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPSTꢀNO gold-plated contacts output, stainless steel base, Kapton®
diaphragm (Teflon® coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed
units.
K
P
V
AA
ME
R
P
F
A
01
01500
Connector
Type
Pressure
Set Point
Actuation/
Application
Pressure
Unit
Packaging
Options
Port Type
Output
Base
Series
Set Point
Options
Kapton® diaphragm
(Teflon® coated),
Nitrile O-ring1
Kapton® diaphragm
(Teflon® coated),
EPDM O-ring2
1 Air, Petroleum-based
hydraulic fluid, engine oil
2 Glycol-based fluid
ME Series
Medium
Pressure
Switch
Rising
Cold-rolled
steel with
Standard
switch
1/4 in Spade
Terminals
Individually
01
boxed units
1,72 bar to 24,13 bar
[25 psi to 350 psi]
psig,
sealed gage
SPST-NO,
gold-plated contacts
factory set,
non-adjustable
1/4-18 NPT
N
V
AA
BA
CA
DA
EA
FA
A
B
C
R
F
A
B
C
K
H
P
B
P
M
Y
E
F
zinc plating
25 individual
Falling
factory set,
non-adjustable
NOTE:
Pressure set point
is always five digits.
Screw
Terminals
With 3 shrink
sleeve
bar,
sealed gage
SPST-NC,
gold-plated contacts
Stainless
steel
boxes packed in
1/8-27 NPT
15 bulk packaging
With shrink
sleeve
(plastic coating)
Deutsch DT04-3P-E005
(3-Pin Connector)
SPDT-NO/NC,
gold-plated contacts
150 units in
bulk packaging
bar,
true gage
Rising,
field adjustable*
1/2-20 UNF
T
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as
01545. This allows for
2 decimal places.
20
M
T
With shrink
sleeve
(acrylic coating)
Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)
Falling,
field adjustable*
NO, with 510 Ω/
0.5 W & 160 Ω/
0.5 W resistors
25 2bu5lkunpiatsckinaging
psig,
true gage
C
D
E
F
1/8-27 PTF
D
* Field adjustable option is only
available for:
1. Blade and screw terminations
(SPDT, SPNO, SPNC)
2. Deutsch DT04-3P
(SPDT, SPNO, SPNC)
psig,
sealed gage
with epoxy
150 individual
10-inch Cable, 18 AWG
(Wire Out, No Connector)
With 1/8 W resistor
between terminals
NC, with 3000 Ω/
0.125 W resistor
boxes packed in
30 bulk packaging
M12 x 1.5
M14 x 1.5
G
H
E
F
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
bar,
sealed gage
with epoxy
304,8 mm [12 in]
total wire length
3. Amp Superseal 1.5 (3-pin)
(SPNO & SPNC)
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
Blade and screw electrical
terminations are available
with only the the true gage
option.
With conduit
sleeve
GA
HA
JA
9/16-18 UNF
G
H
G
H
J
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)*
With Vibra seal
for port threads
3/4-16 UNF
10-inch Cable w/
#8-32 screw with
external tooth
lockwasher
Din43650-C
G1/8 BSPP
J
(3-Pin Connector) (18 AWG)*
10-inch Cable w/M12x1
(Brad Harrison Micro) -
21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
914,4 mm [36 in]
total wire length
7/16-20 UNF
K
M
R
KA
With port neck
O-ring for LPS
10-inch Cable w/Packard
Weatherpack Male Terminal -
12020827 (3-Pin Connector)
(18 AWG)*
R1/8 BSPT
R
LA
MA
NA
*** For screw terminal option
only
T
V
Y
Z
M10 × 1.0
R1/2 BSPT
G1/4 BSPP
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
PA
RA
SA
R1/4 BSPT
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector -
SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
TA
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
UA
VA
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)*
WA
10-inch Cable w/ Metripack
2-Pin Shroud Connector
153000287 (18 AWG)
XA
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)*
YA
ZA
AB
BB
CB
DB
EB
FB
GB
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
Deutsch DT04-2P-E005
(2-Pin Connector)
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)*
6-inch Cable with Amp
Super Seal 1.5 - 282080-1
(2-Pin Connector) (18 AWG)
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
8.5-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
Safety and Productivity Solutions 13
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
NOMENCLATURE: LOW PRESSURE
For example, LPR00550PFPVKAAA01 defines a low pressure switch, rising factory set, non-adjustable set point, 55 psi set
point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPSTꢀNO gold-plated contacts output, stainless steel base, Kapton®
diaphragm (Teflon® coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed
units.
K
P
V
AA
LP
R
P
F
A
01
00550
Connector
Type
Pressure
Set Point
Actuation/
Application
Pressure
Unit
Packaging
Options
Port Type
Output
Base
Series
Set Point
Options
Rising
Kapton® diaphragm
(Teflon® coated),
Nitrile O-ring1
Kapton® diaphragm
(Teflon® coated),
EPDM O-ring2
LP Series,
LE Series
Low
Pressure
Switch
Standard
switch
1/4 in Spade
Terminals
Individually
01
boxed units
0,24 bar to 10,34 bar
[3.5 psi to 150 psi]
psig,
sealed gage
SPST-NO,
gold-plated contacts
Brass
factory set,
non-adjustable
1/4-18 NPT
B
N
V
AA
BA
CA
DA
EA
FA
A
B
C
R
F
A
B
C
K
H
T
P
B
P
M
Y
E
F
Cold-rolled
steel with
zinc plating
25 individual
Falling
factory set,
non-adjustable
NOTE:
Pressure set point
is always five digits.
Screw
Terminals
With 3 shrink
sleeve
bar,
sealed gage
SPST-NC,
gold-plated contacts
boxes packed in
1/8-27 NPT
15 bulk packaging
With shrink
sleeve
(plastic coating)
Tefzel® and Kapton®
diaphragm,
Deutsch DT04-3P-E005
(3-Pin Connector)
SPDT-NO/NC,
gold-plated contacts
Stainless
steel
150 units in
bulk packaging
bar,
true gage
Rising,
field adjustable*
1/2-20 UNF
T
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as
01545. This allows for
2 decimal places.
20
M
T
Nitrile O-ring3
Tefzel® and Kapton®
diaphragm,
With shrink
sleeve
(acrylic coating)
Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)**
25 2bu5lkunpiatsckinaging
Falling,
field adjustable*
NO, with 510 Ω/
1 W & 160 Ω/
psig,
true gage
C
D
F
1/8-27 PTF
U
D
EPDM O-ring4
1 W resistors****
* Field adjustable option is only
available for:
1. Blade and screw terminations
(SPDT, SPNO, SPNC)
2. Deutsch DT04-3P
(SPDT, SPNO, SPNC)
150 individual
1 Air, Petroleum-based
hydraulic fluid, engine oil
2 Glycol-based fluid
3 For high temperature
fluid media (LE Series only)
4 For high temperature
fluid media, glycol-based
fluid (LE Series only)
psig,
sealed gage
with epoxy
10-inch Cable, 18 AWG
(Wire Out, No Connector)*
304,8 mm [12 in]
total wire length
NC, with 3000 Ω/
0.125 W resistor
boxes packed in
30 bulk packaging
M12 x 1.5
M14 x 1.5
G
H
E
F
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
bar,
sealed gage
with epoxy
NC with 510 Ω/
With conduit
sleeve
0.5 W and 160 Ω/
0.5 W resistors****
G
H
G
3. Amp Superseal 1.5 (3-pin)
(SPNO & SPNC)
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
**** Available only on LP Series
With Vibra seal
for port threads
Blade and screw electrical
terminations are available
with only the the true gage
option.
GA
HA
JA
9/16-18 UNF
G
H
J
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)*
914,4 mm [36 in]
total wire length
3/4-16 UNF
K
L
True gage option is available
only up to 20 psig set
point for integral connectors
and wire out electrical
terminations.
304,8 mm [12 in]
total wire length with
acrylic sleeve
10-inch Cable w/
Din43650-C
G1/8 BSPP
(3-Pin Connector) (18 AWG)*
914,4 mm [36 in]
total wire length with
acrylic sleeve
10-inch Cable w/M12x1
(Brad Harrison Micro) -
7/16-20 UNF
M
M
R
KA
21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
*** For screw terminal option
only
10-inch Cable w/Packard
Weatherpack Male Terminal -
12020827 (3-Pin Connector)
(18 AWG)*
R1/8 BSPT
LA
MA
NA
T
V
Y
Z
M10 × 1.0
R1/2 BSPT
G1/4 BSPP
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
PA
RA
SA
R1/4 BSPT
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector -
SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
TA
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
UA
VA
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)*
WA
10-inch Cable w/ Metripack
2-Pin Shroud Connector
153000287 (18 AWG)
XA
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)*
YA
ZA
AB
BB
CB
DB
EB
FB
GB
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
Deutsch DT04-2P-E005
(2-Pin Connector)
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)*
6-inch Cable with Amp
Super Seal 1.5 - 282080-1
(2-Pin Connector) (18 AWG)
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
8.5-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
**For electrical termination with SPST option, only SPNO
configuration is available. SPNC configuration cannot be provided.
14 sensing.honeywell.com
m WARNING
ADDITIONAL MATERIALS
PERSONAL INJURY
The following associated literature is available at
sensing.honeywell.com:
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
• Product range guide
• Product line guide
Failure to comply with these instructions could result in
death or serious injury.
• Technical note: Smart Diagnostic Technology
• Product application-specific information
– Application Note: Honeywell Pressure Switches
– Sensors and switches in front loaders
– Sensors and switches in mobile cranes
– Sensors and switches in oil rig applications
– Industrial product line card
m WARNING
MISUSE OF DOCUMENTATION
•
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
•
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship during the appli-
cable warranty period. Honeywell’s standard product warranty
applies unless agreed to otherwise by Honeywell in writing;
please refer to your order acknowledgement or consult your
local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge
those items that Honeywell, in its sole discretion, finds defec-
tive. The foregoing is buyer’s sole remedy and is in lieu of all
other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For
While Honeywell may provide application assistance personally,
through our literature and the Honeywell web site, it is buyer’s
sole responsibility to determine the suitability of the product in
the application.
application assistance, current
specifications, pricing or name
of the nearest Authorized
Distributor, contact your local
sales office. To learn more
about Honeywell’s sensing and
switching products,
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this writing.
However, Honeywell assumes no responsibility for its use.
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
Honeywell Safety and Productivity Solutions
9680 Old Bailes Road
50094081ꢀ5ꢀENꢁIL50 GLOꢂ
October 2016
© 2016 Honeywell International Inc. All rights reserved.
® DuPont™, Teflon®, Tefzel®, and Kapton® are trademarks or registered trademarks of E.I. du Pont de Nemours and Company
Fort Mill, SC 29707
honeywell.com
相关型号:
©2020 ICPDF网 联系我们和版权申明